Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 LAccepted-AOC | L1 | Accepted-AOC TECHNO COMMERCIALLY ACCEPTED BID | |
| 2 | L2₹10.3 L+₹1.3 L (14.2%)Rejected-Finance AT B L 228 BASATI COLONY ROURKELA SUNDARGARH 769041 ODISHA | ROURKELA | SUNDARGARH | ODISHA | 769041 | L2 | Rejected-Finance AS PER TC RECOMMENDATION | |
| 3 | L3₹13.0 L+₹4.0 L (44.2%)Rejected-Finance AT MAA SHAKTI NAGAR PRADHANPARA P O BUDHARAJA DISTT SAMBALPUR ODISHA | L3 | Rejected-Finance AS PER TC RECOMMENDATION |
Tender Value
₹9.9 L
EMD Value
₹12,500
Closing Date
1 Sept 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO E AND M
OFFICE OF SO E AND M BASUNDHARA AREA MCL
Rearrangement Of Power Supply to Barpali RnR Site II And Proposed Central School Of Barpali, at Basundhara Area
2023_MCL_285991_1
MCL/GM/BA/EM/e-Proc/2023-24/07 Date- 12/08/2023
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
BASUNDHARA AREA
AS PER NIT
4 documents required · 4 mandatory
₹12,500
7 Dec 2023
16 Aug 2023
4 Sept 2023
16 Aug 2023
1 Sept 2023
17 Aug 2023
17 Aug 2023 - 21 Aug 2023
Amount
Erection of RCC/ PCC pole of following length in brick ballast and ramming hefoundation, finishing with 150mm thick cement concrete (1 :3:6) layer on top withincluding excavation and refilling etc. as required(Above 8.0 meter and upto 11.0 meter)
Erection of RCC/ PCC pole of following length in brick ballast and ramming hefoundation, finishing with 150mm thick cement concrete (1 :3:6) layer on top withincluding excavation and refilling etc. as required(Above 6.5 meter and upto 8.0 meter)
Supplying and erection of galvanised stay set for 11 KV over headlines complete with 19/ 20 mm dia X 1.8 metres long stay rod,anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stayclamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. staywire and 11 KV strain insulator etc in cement concrete 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominalsize ) foundation including excavation and refilling etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg permetre) V shape cross arm for two 11 KV over head line conductorscomplete with 50 mm X 6mm M.S. flat iron clamps, bolts and nutsincluding drilling holes for insulator pins, bolts, nuts and washersetc (as per drawing) and painting with primer and finish paint asrequired
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 kV over head line conductors complete with 50 mm X 50 mm X 6 mm (angleiron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flatiron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nutsand washers etc. (as per drawing) and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg permetre) pole top bracket/ cross arm for single 11 KV over head lineconductor complete with 50 mm X 6mm flat iron clamp, bolts, nutsand washers including drilling holes for insulator pins, bolts andnuts etc and painting with primer and finish paint as required.
Erection of pole top/ straight two wire/ V shape two wire, angle iron/channel iron, cross arm on33 KV as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm(7.14 kg per metre) double pole cross arm for three wire 11KV overhead line conductors omplete with through bolts and nuts forclamping to the poles, 50 mm X 6 mm M.S. flats welded on one sideto the channel iron and with bolts and nuts on the other side fortying the cross arms together, including drilling holes for insulatorpins/ fittings, bolts, nuts and washers etc (as per drawing) andpainting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KVover head lines as required.
Supplying and erection of 11 KV pin insulator complete with largesteel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of 11 KV disc insulator for 11 KV over headlines with galvanised insulator fittings, ball and socket type andcomplete with galvanised strain clamps, bolts, nuts, washers etc.as required.
6 SWG G.I. wire(550+3% of 550=566.6/10=56.65kg as GI wire is 10mtr/kg)
Erection of G.I. Wire No. 8 SWG including binding etc. as required
Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories,and providing asonry 'enclosure with cover plate having locking rrangement andwatering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.Details of cost for one Set
Supplying and erection of three piece nonlinear resistor typelightning arrestor suitable for 3 wire, 11 KV overhead lines withrated voltage 9 KV (rms) with a nominal discharge current ratingof 5 KA and complete with galvanised clamping arrangement, G.I.bolts, nuts, washers etc. as required.
Supplying and laying 25mmx5mm GI strip at 0.50mtr…… spaced at 50mm. (
Inrtallation of 11/0.415kv,100kva distribution transformer on the plinth complete with connection,testing ,commiossioning etc as reqd(lugs socket etc supplied by the contractor)
Making of platform for fabricated 11 KV DO fuse set,Aligning & fixing the above including testing for its proper operation ( steel material wil be supplied by the contractor)
Making of platform for fabricated 11 KV Gang operated AB switch,Aligning & fixing the above including testing for its proper operation ( steel material,nutbolt etc wil be supplied by the contractor)
Supply and erection of street light bracket
Erection of AB cable (3*95+1*16+1*70)sqmm
Erection of AB cable (3*16+1*25+1*16)sqmm
Erection of AB cable acessories like pole clamp pair,round Ihook ,Suspension lamp,piercing connector et on the pole. (for 05 nos)
Supply of pole clamp pair
Supply of I hook
Supply of suspension clamp
Supply of dead end clamp
Supply of 11 KV grade, DO fuse , 11 KV X 2 pin insulator per phase, 200Ampere,
Supply of 11 KV grade, Gang operated AB switch, double break, 3 post insulator per phase , 400 A , horizontal type
Supply of psc pole 9mtrs long /300KG WL
Supply of psc pole 8mtrs long /200KG WL
Supply of 11/0.415KV, 100KVA ,BIS LEVEL 2,STAR RATING 2 ISMARKED, WITH A MINIMUM GUARANTEE OF 18 MONTHS.IMP-(AGENCY HAS TO TAKE PROPER APPROVAL FROM TPWODL BEFORE SUPPLY OF TRANSFORMER AT SITE AND TAKING APPROVAL OF HT,LT OVERHEAD LINE.SUB-STN,TRANFFORMER ETC FROM ELECTRICAL INSPECTOR OF ODISHA) Capacity-100KVA, Outdoor type, Input voltage-11kV, output voltage-0.415kV, Input configuration-delta, Output configuration-star, Cooling-ONAN, Max. ambient temp-50 deg celcius, max oil tempreture rise-50deg celcius, max. winding temp-50deg celcius
AB CABLE SUPPLY (3*95+1*16+1*70) SQMM
AB CABLE SUPPLY (3*16+1*25+1*16) SQMM
Supply of 36w,230voutdoor type LED light
Supplying,installation, connection ,testing and ommiossioning of "2NO 400A 4POLE 35KA MCCB complete with aluminium lug ,nut bolts,earth connection etc in the existing steel structure/switch stand Etc as required as per direction of engg incharge.
-Making supplying and erection of 1.5 mtrs height structural steel switch stand/penal box(1) 4nos,1.5 mt height 65*65*6 mm MSA @5.8kg/mtrs,(2)MS flat 50*10mm thick 4.0 [email protected]/mtrs for switch base, (3)40*40*6 mm MSA 6.0 mtrs 3.5 kg/mtrs ,(4)MSP 2mm thick 4.0 sqmt,painting,grouting ,drilling of holes complete with etc as reqd as per direction of engg -in-charge. Total steel required 133.92kg
Supplying and stacking at workside hard granite or equivalent as approved by IIC ,hard broken stone (3mm to 45 mmsize,IRC GR11 as approved quality including screening and stscking along road side equidistantly and uniformly including royality ,octroi and all other taxes complete with all leads and lifts (Adeduction of 7.5%is to be made on account of voids in stone metl.Measurement of material is to be taken just be laying work start and payment shall be made only after laying of the material.(1100 -7.5% OF 1100)=936.17
ANALYSIS OF SUB-STATION GATE BY MS CHANNEL,ANGLE AND MS FLAT ms channel(100x50x6)mm -38.2 kg ,MS angle (25x25x3)- 10.6 kg ,MS flat (25x6)8 mtrs-9.44kg complete with painting,grouting,installation etc as requierd .
Painting with aluminium paint of approved brand and manufacture to give aneven shade.Two or more coats on new work 121.45
Supply of RS Joist pole 150*150 *9mtrs long @(34.60kg/mtr*9mtrs*1no)[email protected]/kg=311.40 each
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
Shree Radhe Krishna Electrical Works
DO INFRA AND POWER PRIVATE LIMITED
techsummary_296114.pdf
PDF • 1.70 MB
finsummary_296114.pdf
PDF • 1.70 MB
LOA07.pdf
PDF • 1.12 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .