Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-AOC KOTHENALLOOR KAKKADA P O THIRUVANANTHAPURAM 695505 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695505 | ₹4.6 L | L1 | Accepted-AOC Agreement executed by Suresh T on as per Agt. no. 142/OF/2020-21 dtd. 30/09/2020 |
| 2 | L2₹4.8 L+₹17,599.02 (3.84%)Rejected-AOC | ₹4.8 L+₹17,599.02 (3.84%) | L2 | Rejected-AOC 2nd lowest |
Tender Value
₹5.0 L
EMD Value
₹12,500
Closing Date
25 Aug 2020, 5:00 pmClosed
Superintending Engineer
Thiruvananthapuram Corporation 695033
Providing electrification, CCTV Camera and Radio Kiosk at the John Balan park in Kunnukuzhi ward under City Corporation Thiruvananthapuram
2020_LSGD_377257_1
TMC/SE/E11/MS/565/2020
Open Tender
Electrical Works
Item Rate
90 days
Thiruvananthapuram Corporation
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Yes
online
₹12,500
Yes
22 Apr 2021
17 Aug 2020
27 Aug 2020
17 Aug 2020
25 Aug 2020
17 Aug 2020
Amount
2.3.4. Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 16 way, Double door
2.12.2. Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
2.14.3. Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
2.10.1. Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
5.2. Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
5.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
providing and fixing 6SWG dia GI wire on surface or in recess for loop earthing along with existing surface/recessed conduit/ submain wiring/ cables as required
5.13 Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
90.12.4.20 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 4 core 10 sq mm
90.12.10.3 Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation 63/50 mm or nearest size
90.2.1.1. Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).
90.2.1.1. Single control light point with 6A, three plate ceiling rose
90.2.1.3. Single control light point with out ceiling rose
90.2.1.6. Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.
90.2.1.7. Independent plug
90.3.19.3. Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required 1200 mm 1X20W LED Lamp with box type fixture
Almonard Pedastal air circulator 450 mm
1.27.4 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm)
1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet
1.28.4 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 6 Module
1.23.5 Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 amp socket outlet
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
1.17.1 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 1 x 1.5 sq. mm
1.17.11 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 2 x 2.5 sq. mm
Fabrication, supply & installation of dust and vermin proof, wall mounting, thermoplastic meter box of following size suitable for fixing KSEB meter, fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit.
S & F switch disconnector unit (isolator) complete with handle assmebly, door inter lock and padlocking arrangement of the following ratings
32 A DP SDF
Supply and fixing the following accessories in the existing meter board and giving connections etc.
63A 415 V Bakelite fuse fitting
2-80 A DIN type fuse link of size 000
63 A, 415V, 2 way neutral link mounted on DMC/SMC base.
Supply and drawing the following sizes of multi-core PVC insulated & PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 3 core 1.50 sq mm
MR 1183 36/40W, 4000 lumen LED IP Street light fitting with aluminium housing stove enameled CRCA sheet steel reflector cover acrylic cover complete with THD <10% PF >0.98 RoHS compliant duly wired up for use on 230 V AC supply
Earth work excavation in hard soil and depositing with a lead up to 50 m and lift upto 1.50 m including neat banking
cement concrete 1:2:4 using 20 mm (nominal size) broken stone for reinforced concrete work
Supplying, conveance and installation FM radio set philips make 4000W/ uSB
Supply and providing 400 x 400x400 mm stainless steel box with lock and key for operaing the Radio in time as required
1.00 sq mm(18AWG) twin parallel type speaker wire
Dahua/epplus/Panasonic 16 channel Digital Video recorder full hd 1080 x 1920 .16 Channel HD Camera inputs 1 SATA, 2USB, 1RJ45 (Gigabit) HDMI/VGA simultaneous Video Output Support Multi brand Cameras CMS software support : mobile and Computer
Dahua/epplus/Panasonic IR bullet camera 2 MP PRO HD+ SERIES 2 MP Pro HD +Image sensor Low light Performance, Day/ light, AWB, AGC, BLC ONVIF version 2.4 complaint. IR range of 30 Mtr. 2D/3D- DNR, IP 66
4TB seagate/Thoshiba/WD'Video surveillance hard disk
SMPS power adapters for 8 camera units
6 U rack with PDU hardware kit & cooling fan
UPS 600 VA for surveillance system
Laying charges for fenolex/chetan 3+1 CCTV cable with ISI granded PVC pipe Accessories & conduits, cable etc
32 LED TV Samsung/LG (for main view)
Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding excavation and concrete base ) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.
Supply and installation of Hensel make IP 65 terminal Junction box for termination 1.50 sq mm 3 core cable for steet light post
RADIANT ELECTRICALS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_534645.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .