Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹11.7 L+₹1.5 L (14.8%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹9.7 L
EMD Value
₹19,480
Closing Date
14 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) NO 2 JODHPUR
GE (AF) NO 2 JODHPUR
PROVN OF GUARD REST ROOM FOR STN ARMOURY AT AF STN MANDORE UNDER GE (AF) 2 JODHPUR
2020_MES_371700_2
8174/E8
Open Tender
Civil Works
Item Rate
240 days
GE (AF) NO 2 JODHPUR
As per tender documents
6 documents required · 6 mandatory
₹500
GE (AF) NO 2 JODHPUR
₹19,480
Yes
14 Dec 2020
26 Sept 2020
16 Oct 2020
26 Sept 2020
14 Oct 2020
1 Oct 2020
60 days
Amount
BOQ has been uploaded as per item's of Sch of Works. Contractors are advised to quote the same rates of items of same nature & specification of under various parts otherwise lowest rates will be considered while calculation of Q-Bid & payments. Part-I : Buildings Works
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out hard rock all as specified and directed
Rough excavation not exceeding 1.5m deep and getting out any type of soil all as specified and directed
Removing excavated material exc. 1.5km but n exc. 5 m and depositing where directed
Forming embankments of soil including raising (or lowering) earth, spreading in layers n exc. 30cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5m high from base complete all as specified and directed
M&L Cement concrete type D2 1:4:8 (40 mm graded aggregate) in foundations, filling and mass-concrete complete all as specified and directed
Formwork to flat Rough finished surfaces of concrete sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to better complete all as specified and directed
Formwork square, rectangular or polygonal to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed
Formwork to flat Rough finished surfaces of concrete sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed
Formwork to flat Rough finished surfaces of concrete soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) complete all as specified and directed
Formwork to flat Rough finished surfaces of concrete to chullah hoods, chajjas, troughs and similar items including edge complete all as specified and directed
S&F for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
S&F for TMT steel bars 6-8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
S&F for TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups, spaces and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for Reinforced cement concrete (Design mix) M-25 (20mm graded aggregate) for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concretecomplete all as specified and directed
M&L for Reinforced cement concrete (Design mix) M-25 (20mm graded aggregate) for Columns, pillars, piers, posts and struts complete all as specified and directed
M&L for Reinforced cement concrete (Design mix) M-25 (20mm graded aggregate) for chajjas complete all as specified and directed
M&L for Reinforced cement concrete (Design mix) M-25 (20mm graded aggregate) for beams, cantilevers bressummers, lintels over 1.5m complete all as specified and directed
M&L for Reinforced cement concrete (Design mix) M-25 (20mm graded aggregate) for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like complete all as specified and directed
ATT Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured) complete all as specified and directed
ATT Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed
ATT Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed
ATT Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed
M&L for 75mm thick cement concrete type D2, 1:4:8 (40mm stone aggregate) as in sub base complete all as specified and directed
M&L for 25mm thick cement concrete type B0, 1:2:4 (12.5mm stone aggregate) as in base complete all as specified and directed
M&L for Pre-cast cement concrete Type C1 1:3:6 (20 mm graded aggregate) set in CM 1:6 block masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete all as specified and directed
M&L for precast cement concrete Type C1 1:3:6 (20 mm graded aggregate) set in CM 1:6 solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed) setting in mortar, complete, in walls complete all as specified and directed
M&L for PCC 1:2:4 type B-0 (12.5mm graded aggregate) as in cill, steps plinth courses, string courses, coping, benching and including weathering, slightly rounded or chamfered angles etc complete all as specified and directed.
M&L for cement plaster 1:6 Rendering 10mm thick on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and directed
M&L for cement plaster 1:3 Rendering 5mm thick on ceiling complete all as specified and directed
M&L for cement plaster 1:4 rendering 15mm thick on external surface finished even and smooth (without using extra cement) complete all as specified and directed
M&L for Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over Screed bed or bedding layer or mortar 15mm CM 1:4 complete all as specified and directed
M&L for Machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and mirror finish complete over Screed bed or bedding layer or mortar 15mm CM 1:4 complete all as specified and directed
M&L for kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over Screed bed or bedding layer or mortar 15mm CM 1:4 complete all as specified and directed
M&L for coloured joint free Glazed ceramic tiles in vertical surface 350x250mmx7mm/450X350X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over Rendering 10mm thick CM 1:3 on fair faces of brick work or concrete surfaces complete all as specified and directed
Preparing of new surfaces, plastered or unplastered and applying three coat of white wash on ceiling complete all as specified and directed
Preparing of new surfaces, plastered or unplastered and applying two coat of oil emulsion distemper on walls over one coat of alkali resist primer over a thin layer of putty complete all as specified and directed
Preparing of new surfaces, plastered or unplastered two coat of cement base paint over one coat of primer on external walls complete all as specified and directed
Supply and laying 25mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed.
Supply and laying 20mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed.
Supply and laying 15mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed.
S&F 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20mm brass gate valve and 20 mm bore ball brass valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic plastic ball screwed for iron pipe and fixed. (Minimum weight of ball valve - 210 gms)
S&F 15 mm bore bib taps fancy type cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified and as directed by Engineer-in-Charge.
S&F 15mm bore pillar tap fancy type, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge.
S&F 15 mm bore fancy type stop valve, cast copper alloy, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions.
S&F 15 mm bore long shank concealed stop valve, cast copper alloy, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions.
S&F brass chromium plated shower rose of 125 mm size with swivel joint including fixing to steel pipe or union.
S&F in repairs 15 mm bore brass chromium plated bib cock two in one with angle cock including fixing to steel pipe or union.
S&F in repairs brass chromium plated health faucet of 15 mm bore complete.
S&F vitreous china wash basin, white, flat back, size 550x400mm including brackets, cutting for and pinning in ends of brackets or erecting stand, brass chromium plated perforated waste coupling/ fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed with 32mm dia pvc waste pipe fixed complete all as specified.
S&F vitreous china wash down water closet pan (pedestal pattern), white, with and including plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, PVC valveless, syphonic action type, flushing cistern, low level, 10 litres capacity, white, with inlet, ball valve, float and handle including brackets including PVC flushing pipe, 32 mm dia and fixed complete all as specified.
M&L for 75mm dia Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed
M&L for 100mm dia Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed
S&F PVC connection 15 mm size with PTMT nuts of length 450 mm.
S&F in repairs stainless steel soap dish made of stainless steel 1.00mm thick, approximate 150x150 mm fixed to plugs with chromium plated brass screws complete all as specified and directed.
S&F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges.
S&F sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed
S&F in grating doom 100 mm dia of PTMT (minimum weight 25 gms)
S&F solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube, fixing in opening as per specification and drawing.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, and fixing in the frame at site as per specification & drawing.
S&F Pressed steel frames size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified, supplied and fixed
M&L for PCC type C-0, 1:3:6 (12.5mm stone aggregate) as in frames complete all as specified and directed.
M&L for 35mm thick second class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); supplied and fitted to chowkats but divide into square with with plain, chamfered or roun0ded, mitred and rebated sash bars, any numbers.
S&F second class HW rail and style Plain framed, 35mm thick panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed
S&F for 100mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed type C-21 complete all as specified and directed
S&F 150 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed complete all as specified and directed
S&F aluminium handles, cast type, anodized, of size 100mm complete all as specified and directed
S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed
S&F Steel windows box type side hung shutters including tower bolt, handles, hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed
S&F Steel windows box type side hung shutters including tower bolt, handles, hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed
S&F 3mm thick glass pin headed type, ordinary quality and glazing with oil putty in square in exc 0.5 sq.m in each pane complete all as specified and directed
S&F Galvanised mild steel wire cloth, 0.46mm nominal dia of wire and average width of aperture 1.00mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed
S&F Steel ventilators with top hung shutter including hinges, steel peg stay, complete all as specified and directed
M&L for 100mm dia sand cast pipe Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floor
M&L for 100mm dia sand cast pipe Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, fixed in walls.
M&L for 75mm dia sand cast pipe Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, fixed in walls.
S&F 100 mm dia bends with ducks foot or heel rest complete all as specified and directed.
S&F 75 mm dia bends with ducks foot or heel rest complete all as specified and directed.
S&F 100mm dia cast iron branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches pipe.
S&F 75mm dia cast iron branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches pipe.
S&F for CI cowl 100mm dia fixed complete
M&L Hardcore of stone boulders gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed
M&L for 75mm thick Cement concrete type C-2, 1:3:6 (40mm graded aggregate) complete all as specified and directed
M&L for 10 mm thick rendering in CM 1:3 over concrete surfaces (Roof) mixed with water proofing compound @ 3% by weight of cement complete all as specified. NOTE : Water proofing compound shall be measured and paid for separately as “Supply only”
M&L for applying roof treatment on top of roof with APP modified membrane (minimum 3 mm thick) with non-woven polyster reinforcement/mat (centre core) with thermal insulation with white mineral gravel finish on upper side of membrane laid by torch application method with overlaps 100mm on length side and 100 mm on the width side as per manufacturer’s instructions over and including a coat of approved cold applied bituminous oil based primer (IS- 3384) @ 250 gm/sqm complete all as specified and as directed by Engineer-in-Charge.
Preparation of newly surface any description, not otherwise, described, over 10cm width or girth and apply two coat of synthetic enamel paint on wooden surface over one coat of pink primer complete all as specified and directed.
Preparation of newly surface any description, not otherwise, described, over 10cm width or girth and apply two coat of synthetic enamel paint on steel surface over one coat of red oxide complete all as specified and directed.
Supply only integral water proofing compound ISI marked.
S&F drapery rod in any length, high strength MS pipe with corrugated PVC extrusion having outer dia 20 mm with plastic ring of ABS plastic of dia 56 to 58 mm complete all as specified and directed.
S&F decorative finals ABS plastic in matching colour of steel powder quoted paint of same colour of rod or as directed by Engineer-in-Charge.
Part-II : Site Clearance
Excavation over areas, n exc 1.5m deep and getting out in hard rock.
Part-III : Path/ Hard Standing
Surface excavation n.exc. 30 cm deep and averaging 15 cm deep and getting out in soft/ disintregated rocks
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft / disintregated rock.
M&L for PCC 1:5:10 type E2 (using 40mm graded stone aggregate) as in cement concrete in foundation filling and mass concrete all as specified and directed.
Pre-cast cement concrete block masonry type C1 1:3:6 (20 mm gr stone aggregate) with solid blocks, exc. 10 cm in width and setting in mortar 1:6, complete
M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces In CM 1:4 finished even & smooth without using extra cement. NOTE : Water proofing compound shall be measured and paid for separately as “Supply only”
Supply only integral water proofing compound ISI marked.
Removing excavated material exc. 1000 m but n.exc. 1500 m and depositing where directed at a level n.exc. 1.5 m above the starting point.
Returning, filling in soft/disintregated rock, including spreading, leveling, watering and well ramming in layers not exc. 25cm.
M&L for Cement concrete type D2 1:4:8 (40mm graded aggregate) in foundations, filling and mass-concrete complete all as specified and directed.
S&F Chequered cement concrete rubberised tiles with white cement and pigment of size 20cm x 20cm x 25mm thick, set, jointed and pointed in near cement slurry in floors etc. over and including 20mm thick screed bed of CM 1:6 complete all as specified and directed. .
Part-IV : Security Fencing & Gate
Excavating in post holes (or similar) each n. exc 0.5 cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm as in hard rock
M/L cement concrete type C-2, 1:3:6 ( 40 mm graded aggregate) in foundation filling mass concrete for post holes etc complete all as specified and directed.
S&F mild steel joist, angle, channel or tee sections drilled and countersunk for balusters running bars for doors, balusters, nosing to steps including embeding in concrete and screwing etc. Wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc fillet iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe 410-0 or Fe 310-0.
Fixing onlychain link fencing including line wire any mesh size and type to any type of standards rails, straining bolts etc inlcluding provision of binding wire
Supply only chaink link MS galvanised fencing any size or type weight n exc 4.00 Kg
S&F mild steel TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending hooking etc and binding with MS wire 0.9 mm dia (annealed)
M&L two coats of synthetic enamel paint over a coat of red oxide primer including preparation of newly steel surface.
S&F mild steel bolt purpose made with hexagonal or square head one end screwed the other end or screwed both ends each screwed to be fitted 3d with washer and one hecagonal or square nuts exceeding 10 cm and n exc 15 cm long dia of the shank 11 to 15 mm
Part-V : Sewage Disposal
Excavating in trenches in soft/disintregated rock, n.exc. 1.5m wide and n.exc 1.5 in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n.exc. 10 Sqm on plan and n.exc 1.5m in depth and getting out.
M&L for Cement concrete (1:4:8) type D2 using 40 mm graded stone aggregates as in foundation, filling and mass concrete all as specified and directed.
M&L for Pre-cast cement concrete block masonry type C1 1:3:6 (20 mm gr stone aggregate) with solid blocks, exc. 10 cm in width and setting in mortar 1:6, complete
M&L for cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in surface channels, drains (forming fair finished channel shall be measured and paid for separately).
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement incl forms, moulds,mitred/stopped ends etc.
M&L Rendering 10mm thick on fair faces of brick work or concrete surfaces In CM 1:4 finished even & smooth without using extra cement. with using integral Water Proofing compound all as specified and directed. Note : Integral Water Proofing compound shall be measured and paid for separately as “Supply only”.
Supply only integral water proofing compound
Cement concrete (1:2:4) type B1 using 20mm graded stone aggregate as in coping bed block and like including necessary form work and finishing surfaces fair and even without using extra cement.
Precast reinforced cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregates) for manhole cover slabs, set in CM 1:6, including necessary form work moulds etc all as specified. (Reinforcement shall be measured and paid for separately).
Mild steel TMT bars in reinforcement 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with & including mild steel (annealed) wire not less than 0.9 mm dia.
Returning, filling in soft/disintregated rock, including spreading, leveling, watering and well ramming in layers not exc. 25cm.
Removing excavated material exc 500m but n exc 500m and n. Exc 1.50 KM depositing where directed.
Cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate as in bed to drain pipe including forming cradles complete for pipe of size 200 mm bore all as specified and as directed.
Salt glazed stone ware drain pipes of 200 mm internal dia, grade `A’ ISI marked laid to slope in trenches, jointed in CM 1:1 and tested complete all as specified and as directed.
Part-VI : Drain
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft /disintregated rock.
PCC (1:4:8) type D2 using 40 mm graded stone as in foundation filling and mass concrete.
Pre-cast cement concrete block masonry type C1 1:3:6 (20 mm gr stone aggregate) with solid blocks, exc. 10 cm in width and setting in mortar 1:6, complete
Providing cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in surface channels, drains (forming fair finished channel shall be measured and paid for separately).
Extra for forming fair finished drain or channel 40cm inner girth in cement concrete using extra cement incl forms, moulds,mitred/stopped ends etc.
Cement concrete (1:2:4) type B1 using 20mm graded stone aggregate as in coping bed block and like including necessary form work and finishing surfaces fair and even with using extra cement.
M&L Rendering 10mm thick on fair faces of brick work or concrete surfaces In CM 1:4 finished even & smooth without using extra cement.
Returning, filling in soft/disintregated rock, including spreading, leveling, watering and well ramming in layers not exc. 25cm.
Removing excavated material (soil) exc. 1000 m but n.exc. 1500 m and depositing where directed at a level n.exc. 1.5 m above the starting point.
Part-VII : Internal Electrification
Point wiring for one light/ fan point controlled by one way switch using 1.5 Sq mm copper conductor cables (multistanded) PVC insulated and unseathed in and including PVC concealed conduit (thickness not less than 1.5 mm and 20mm dia), medium grade with sunk Cl / Pressed steel terminal boxes with 3mm thick laminated sheet cover including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.0 Sq mm as earth wire stranded and conected to earth dolly as specified.
All as per srl item No 1 but for 3 pin 5 Amps socket outlet independent including copper PVC insulated PVC unsheathed 1.50 sq mm earth wire and connected to earth dolly.
All as per Srl item No 1 but for 3 Pin 15 Amps socket outlet independent with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire standard and connected to earth dolly.
S&F Switch piano flush type 5 Amps single pole one way
M&L for Switch socket combination 2-in-1, 3 pin 5 & 15 Amps flush type.
M&L for Switch socket combination 2 in 1, 5 pin 5 Amps flush type.
M &L Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block complete
M&L for sheet metal enclosures distribution board double door where MCB to be used with 200 Amps rated bus bar CL-IP-43 415 V, 4 way tripple pole & neutral link
M&L in replacement for MCB triple pole & neutral 63 Amps.
Supplt and Fixing sheet metal enclosures for DBs when MCBs to be used double door single pole and neutral 8 way 240 volts with 200 Amps rated bus bar. (Note - DB to be flushed with wall as directed)
S&F MCB single pole & neutral 240 volts 32 Amps
S&F MCB single pole 6 to 30 Amps.
Supply & fix LED tube light along with fixture,20W with effenicy 100 lumen/watt complete all as specified and as directed.Make -Crompton Model No-LCTLN-20-WWor eqult Bajaj/Havells.
S&F bakelite angle lamp holder with back plate suitable for batten fitting
S & F Enviromental friendly , surface mounted , bulk head fitting with high brightnesss IP 54 Protections complete all as specified and as directed.Make-Crompton Model No-LBHP-10-CDL or equivalent Bajaj/Havells
S&F Electronic step type fan regulator 230 volts 50 C/S all as specified including all as specified
S&F Ceiling fan 1400 mm sweep complete set without regulator including connecting to ceiling rose with twin twisted flexible copper cable .
M & L Repair in replacement sub main wiring with 2 run of 6 Sq mm single core copper conductor cable drawn through in rigid PVC conduit ISI marked with fitting and 4.0 Sq mm single core copper conductor cable for continues earth wire all as directed
Supply install testing and commissioning of water heater storage type ,electric supplied and installed complete capacity 25 Ltr with BEE 5 star rated complete all as specified and as directed.Make -Havells Instanio Prime Model No-GHWAICTWH025 or eqult Bajaj/Crompton.
M & L Cutting in position and providing Tee 25x15mm screwing the existing GI tubing for addn/altns of size 25 mm dia complete all as specified and as directed.
.S & F GI Tubes 15 mm dia, medium grade, galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Supply & fix Bib taps 15 mm brass chormium plated with curtch or butterfly handle complete all as specified and as directed.
Supply & Fix Valve stop screwed supplied and installed complete for size 15 mm dia. complete all as specified and as directed.
Supply & Fix PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
S&F in repair Building Security LED 36 Watt fixture made of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP65 protection ,commercial building including connection all as per cat ref no. LSTS-36-CDL-M complete all as specified and directed by Engineer in Charge. Make -Philips or equivalent CG/ Havells S&F in repair Building Security LED 36 Watt fixture made of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP65 protection ,commercial building including connection all as per cat ref no. LSTS-36-CDL-M complete all as specified and directed by Engineer in Charge. Make -Philips or equivalent CG/ Havells
Supply install testing and commissioning of desert cooler electric driven single phase having nominal air flow capacity 1800 cum/hr complete and with frame made out of 40x40x6 mm angle iron frame and 1.5mm sheet thickness of suitable stand size complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm 6.0mm thick, buried directly in ground (earth pith not less than 2.25 mtr deep below ground level) with top edge of plated not less than 1.5 mtr below normal ground level connected toincl galvanized iron or steel earth lead wire 4.0mm dia by mean of bolts nuts check nuts & washers of galvanized iron or steel pipe 15mm dia medium grade and connected to main switch board watering pipe shall be 20mm dia GI medium grade incl excavation earth work in any type of soil pit RCC cover complete.
Part-VIII : External Electrification
Supply & Laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated aluminium conductor standard served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of 10 Sqmm x 4core size all as specified. Note : Earth work and other connected work shall be measured & paid sperately.
Excavation in trenches and exceeding 1.5m wide and not exc 1.5m in depth in hard/dense soil and getting out all as specified.
Returing, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick all as specified.
Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
M & L Dry sand for sand cushioning to under ground cable 8 cms thick before laying the cable before and 15 cms thick after laying & streching the cable in trenches, including hand punning and consolidating complete as specified. Note : for payment purpose punned thickness shall be measured
M & L stone Slab 40 to 50 mm thick rough dressed jodhpur stone patties/ slab cover in trenches for protection of cable 25 to 30 CM wide and thickness not less than 50 mm in length lay dry abutting each other with gap between adjacent slab not exceeding 10 mm over sand cushioning.
Supply and fixing GI tubing light grade 40 mm dia along the wall/ in trenches/ in duct / in culvert /road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holdining of GI pipe alongwith poles all as specified and directed.
M/L for boring of road corssing of size 100mm dia by sing trenchless technology with use of machinery equipment complete without damaging the surface at suitable depth for drawing cables/ pipe lines etc.
Part-IX : External Water Supply
S/F tubes Medium grade galvanised with all fittings as Tees, bends, etc laid in trenches of size:-
25 mm bore
50 mm bore
Excavation in trenches n.exc 1.50 m wide & n.exc 1.5m deep for taking out / laying pipe line & getting out in hard/dense soil.
Returning, filling in and including spreading levelling watering & well ramming in layers n.exc 25cm in soil.
Removing excavated soil n.exc 50m above the starting point
S/F gate valves gun metal with iron wheel high pressure screwed both ends for iron pipe or for union and fixed or following sizes:-
25 mm dia
50 mm dia
M/L for cement concrete in foundations surfaces filling and mass concrete type C2,1:3:6(40 mm graded aggregate .
Cutting cast iron pipes and reducing to required length for inseration of new branch tees valve complete 80mm size all as specified and as directed.
Bansal Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .