Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical R O RAMSHILLA P O AKHARA BAZAR DISTT KULLU | SHIMLA | HIMACHAL PRADESH | 172001 | Accepted-Technical Eligible |
| 2 | Accepted-Technical | Accepted-Technical Eligible |
| 3 | Accepted-Technical | Accepted-Technical Eligible |
Tender Value
₹4.0 L
EMD Value
₹8,000
Closing Date
2 Feb 2026, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Jal Shakti Division Kullu
Regarding shifting of pipe line water pipe near Sultanpur parking Ward No.4
2026_HPIPH_126576_1
11082-11131 Sultanpur Parking
Open Tender
Civil Works
Item Rate
60 days
Sultanpur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Executive Engineer
₹8,000
18 Feb 2026
23 Jan 2026
3 Feb 2026
24 Jan 2026
2 Feb 2026
24 Jan 2026
Excavation in foundations, trenches etc.in all kind of soil in all leads and lifts such as pick work, jumper work in saturated/unsaturated soil including bailing out water, blasting work in hard/ soft rock or chiseling in hard/soft rock where blasting is prohibited in all lifts stacking the excavated earth not more than 3 mtrs clear from the edge of excavation and then returning the stacked soil in 15 cm layers when required into plinths sides of each deposited layer by ramming and watering and then disposing of all surplus excavated earth foundations etc., consolidating as directed within all leads and lifts and handing over the useable materials available from excavation to department free of cost as per direction of Engineer-in-charge with in all leads and lifts.
Providing and laying in cement concrete 1:3:6(1cement 3 sand 6 graded stone agg.40mm nominal size) and curing complete excluding cost of form work in foundation and plinth with in all leads and lifts
Providing and fixing 0.50mm thick prepainted steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 microns over 5 microns primer coating to back coat of polyster of 5 microns over 5 microns primer coating i/c fixing with prepainted iron J or L hooks, bolts and nuts 6mm dia meter with prepainted limpet and rubber wshers complete with all accessories as required as per the direction of Engineer in charge.
Steel work welded in built up section , trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of red paint in gratting framed gurad bars, laseers , railing etc. complete with in all leads and lifts as per the entire satisfaction & direction of the Engineer-in-charge.
Retrieving of old MSERW pipe 250 mm dia from Nallah to the site of work lead up to 100 mtr (average) including cutting (electric arc welding/gas cutting ), dismantling, cleaning/flushing, carriage by means of labour (manually), laying along the alignment and other required equipments like chain pulley, hooks along with necessary accessories and safty equipments complete in all respect as per direction of Engineer-in-charge.
Relaying, jointing (by way of circumferntial butt welding joints by electric arc welding ) and testing of Mild Steel Electric Resistance Weld tubes ( MSERW) of following diameter confirming to ISO:3589:2009 Steel grade X-42 ( latest with up to date ammendments) having minimum wall thickness as per IS code with bevelled/ plain ends in a random lengtth of 4 to 7 meters , including manufacturing reducers/ tapers, all short pices bends etc and class of pipes specified below, provided and jointe as per site requirement made from parent tubes. including lowering and laying in excavated trenches to ensure required level including flushing , cleaning and hydraulic testing complete in all respect to the satisfaction of engineer in charge . the fabricated bends shall have three or four cuts having its radius not less then five times the dia of pipe . the damaged portion of the pipes and specials made from the parant tube during welding or otherwise shall be provided anticorrosive treatment by applying two coats of anticorrosive bitumenous paint over a primming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately). 250 mm dia MSERW
Providing and fixing double flanged Cast Steel sluice valve ASA-600 Class-I IS: 780-1984 of Kirloskar/Leader/Bhel/Pelican/ Kartar make 150 mm dia for the pipe line capable to withstanding normal seat pressure including cutting, welding, providing and fixing rubber/asbestos sheet of maximum thickness 3mm as per IS: 2712-1979 and providing and fixing MS nuts and bolts in required number including carriage of material in all leads and lilfts.
Demolishing cement concrete of nominal mix 1:4:8 or leaner mix (including equivaelnt design mix) manually/by mechanical means including disposal of material within 50 metres lead all complete as specified & as per direction & entire satisfaction of engineer-in-charge.
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.36 MB
FORMSIX.pdf
Tender Documents • 0.31 MB
FORMEIGHT.pdf
Tender Documents • 1.43 MB
BOQ_186699.xls
BOQ • 0.28 MB
TERMANDCONDITION.pdf
Tender Documents • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .