Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-AOC SUBHASH PALLY WARD NO 4 P O P S KOKRAJHAR DIST KOKRAJHAR BTC ASSAM PIN 783370 | KOKRAJHAR | KOKRAJHAR | ASSAM | 783370 | ₹3.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.3 Cr+₹6.0 L (1.87%)Rejected-AOC SUBHASH PALLY WARD NO 3 P O KOKRAJHAR P S KOKRAJHAR DIST KOKRAJHAR BTC ASSAM | KOKRAJHAR | ASSAM | 783331 | ₹3.3 Cr+₹6.0 L (1.87%) | L2 | Rejected-AOC L2 |
| 3 | L3₹3.3 Cr+₹9.0 L (2.80%)Rejected-AOC WARD NO 3 SUBHASHPALLY P O P S KOKRAJHAR DIST KOKRAJHAR BTC ASSAM PIN 783370 | KOKRAJHAR | KOKRAJHAR | ASSAM | 783370 | ₹3.3 Cr+₹9.0 L (2.80%) | L3 | Rejected-AOC L3 |
Tender Value
₹3.2 Cr
EMD Value
₹6.4 L
Closing Date
17 Feb 2020, 4:30 pmClosed
Sri J.M. Basumatary
O/o the Addl. Chief Engineer-cum-Director, PWD, BTC, Kokrajhar.
Const. of proposed Office Building for Executive Engineer, PWD, Building Division, Kokrajhar, BTC, Assam.
2020_BTC_16240_1
27/KOJ/IFB/2016-17/PT-I/15
Open Tender
Civil Works - Building
Item Rate
730 days
Kokrajhar
Refer to SBD
6 documents required · 6 mandatory
₹9,600
Principal Secretary, BTC, Kokrajhar
₹6.4 L
Yes
5 Mar 2020
3 Feb 2020
18 Feb 2020
3 Feb 2020
17 Feb 2020
3 Feb 2020
3 Feb 2020 - 17 Feb 2020
Amount
(CIVIL WORKS) GROUND FLOOR: EARTHWORK IN EXCAVATION 1.1. (A) a Earthwork in excavation for foundations, trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, braking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lift as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Upto a depth of 2.00m below the existing ground level. (a) In ordinary soil
1.3. (c) Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
PLAIN CEMENT WORKS 2.1.1. (a) Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls,brick work etc. as directed and specified including dewatering if necessary, and curing complete (shutering where necessary shall be measured and paid separately). (a) In prop 1:3:6 (1 cement : 3 coarse sand : 6 coarse agg. by volume (using mixture machine)
2.2.1 (A) (b) Providing and laying plain/reinforced cement concrete works with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work & reinforcement for reinforced cement concrete works (form work and reinforcement will be measured and paid separately) Using mixture machine (A) In sub structure upto plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit & the like and other works not less than 100mm thick upto plinth level. (b) M20 or Prop. 1 : 1.5 : 3
2.2.1 (B) (b) (B) In supers structure from plinth level upto 1st floor level Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing the top surface & finishing of nosing. (b) M20 or Prop. 1 : 1.5 : 3
2.1.2 (b) Plain cement concrete floor base in prop. 1:3:6 laid in alternate bays as specified with coarse Aggregate of size 13mm to 32mm including dewatering if necessary , and curing etc. complete (b) 50mm thick.
2.1.3 Providing and laying 25mm thick Damp Proof Course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc complete as directed.
3.2.1.1 (a) Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in : Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
3.2.1.2 (ii) Sides of Tie beams, Grade beams etc. at or below Ground level.
3.2.1.1 (ii) Columns, Pillars, Posts & Strut (a) Square , Rectangular , polygonal in plan or any shape like Tee /L etc. having plane vertical face.
3.2.1.2 (ii) Sides and soffits of beams, beam haunchings , cantilever giders , bressumers , lintels and horizontal ties. a) For depth not excding 1.0 M
3.2.1.3 (ii) Formwork Flat surfaces such as soffits of suspended floors , roofs landing , cantilaever slabs chajjas , balconies and like a) Floor etc up to 200mm in thickness
3.2.1.8 Staircase with sloping or stepped soffits including risers and stringers but excluding landing.
3.2.1.6 Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
4.1.1. Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the sub grade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
4.1.4 223 mm thick 1st class brick work in cement mortar including racking out joints and curing complete as directed in sub structure up to plinth level (protruding M.S rod/Tor steel of column to be embedded in cement mortar and will be measured and paid separately) (a) In cement mortar in proportion 1:4 (1 cement: 4 sand)
4.1.8 112mm thick 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding MS rod/Tor steel of column to be embedded in cement mortar and will be measured and paid separately) a) In cement mortar in proportion 1:4 (1 cement : 4 sand)
6.2.2 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. (A) On rough side (c) In cement mortar 1:5
(B) On fair side (c) In cement mortar 1:5
6.2.1 10mm thick cement plaster in single coat on fair side of brick/concrete walls for interior plastering upto 3rd floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. (d) In cement mortor 1:6
13.3.5 Providing two coats of J.K. wall putty (white cement based putty for concrete /mortar walls and ceiling both internal And external) after removing all loosely Adhering materials from the wall surface With the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coates is maximum 1.5mm).
13.5.2 Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem “Rakshak” brand of required shade by thinning 11ltr. of paint with 750ml of water to give an even shade after thoroughly brooming the surface to remove all dirt and remains of loose powdered materials as specified and directed by the department. (c) Asian paint / Berger paint / ICI ect.
13.4.7 Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a).Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
13.5.1 Applying one self-priming coat of acrylic emulsion coating of Unicem "Rakshak" brand by thinning 1ltrs of paints with 1ltrs of water over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department.
13.6.5 Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/ Neroalc) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter sand papering and stopping. (i) Surfaces over 100mm in width or girth. (a) enamel paint
13.6.3 Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (b). With ready mixed paint , wood primer (white).
5.11.1 Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. 5.11.2 VITRIFIED (i) Normal range (Sizes 300 mm x 300mm and above) Somany made- Durastone (Unpolished heavy duty Vitrified Tiles) (b). Deluxe
5.10.3 Providing polished granite tiles of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) (ii) With White cement
5.7.2.2 Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department). i) Of size 300mmx450mm and above
5.7.2.1 Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) b) Executive range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make i) Of size 800mmx800mm and above
5.7.3.1 Providing polished SUNROCK-Hi CTS/ MULTIWYN tiles of approved quality, size, shape and thickness not less than 18mm on floors and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (a) SUNROCKHi CTS TILES ii). Old Castle (455x455) mm
5.5.5: 18 mm thick marble chips skirting or dado rubbed and polish to granolithic finish with under layer 12 mm thick in cement plaster in prop. 1:3 (1 cement :3 coarse sand) and top layer 6 mm thick with marble chips of any colour or combination of colours of 4 mm nominal size laid in cement marble powder mix 3:1( 3 cement : 1 marble powder by weight in proportion of 4:7 (4 cement marble powder mix : 7 marble chips by volume) (a) Pigment of any shade with ordinary cement in top layer only.
5.7.3.4 Providing polished tiles of approved quality, size, shape of specified thickness on pavers over a base of 100mm compacted sand gravel including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (C) VITA Tiles (Pavers) (i) Ivory (300x300) mm
7.10.1: Providing and fixing, in position suspended false ceiling using E-Grid (exposed ceiling suspension 2430 system) of grid size 600mm x 600mm/1200mmx600mm with main runner 38 x 24mm, cross tee 29mm x 24mm & wall angle 24mm x 24mm . Using 4mm/6mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Board as per IS 14862, to be placed in a grid of G.I. system duly suspended with 4mm/6mm dia G.I/M.S bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450mm from the adjacent wall. Flush fitting 1220mm cross tee to be interlocked between main runners @ 610mm c/c, so as to form 600mm x 600mm/1200mmx600mm grid, all complete as per the drawing & directions of engineer-in-charge. (A) Standard Ceilings of Everest make or equivalent as directed by the departement (ii) Using 6 mm thick FC Board
9.1.2: Providing wood work in frame (chowkhats) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (a) With 1st class timber (Bonsun /Sundi)
9.9.3: Providing, fitting and fixing factory made wooden panelled doors with panel inserts of 75mm to 50mm width and 12mm to 20mm thickness,joined together with continous tongue and groove joints glued together with Movicol or other approved adhesive leaving a vertical groove of 7.5mm to 15mm between the inserts,the edges of panel inserts being feather tongue into styles and rails including providing three pairs of oxidised M.S butt hinges (100mm x 75 mm x 3.55mm) and furnishing with moulded timber beading of size 25mm x 15mm around the panels complete as per drawing (moulded timber bead and all fittings except hinges to be paid separately). (b) With 1st class local wood(Hollock / Bola/ Bonsum) (iii) 35 mm thick with panel inserts of 20mm thickness.
11.1.2: Providing, fitting and fixing anodized aluminium sliding windows and ventilators of standard sections approved brand (HINDALCO/NALCO/BALCO/JINDAL/ other equivalent primary producer) without horizontalglazing bars, jointsmitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, Angle cleat, rubber gasket,roller, bolting Device, locking arrangements, servews, etc.as reqd. complete as specified and directed for all levels. (b) 3 Track sliding window (iv) 5mm clear glass
(a) 2 Track sliding window (iv) 5 mm clear glass
10.2: Providing, fitting & fixing plain MS grill of required pattern for windows/ ventilators/fixed glazing & other openings with MS sq bars & flats as per details provided including welding to the frames & finishing with one coat of red oxide primer and two coats of enamel paint. (b) Plain grill. (a) Fixed to wooden Frames.
15.2.1: Supplying , fitting ,fixing anodized aluminium fitting of approved make , reasonably smooth , free from sharp edges and corners , flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodized to bright natural matt & satin finished). (b) Tower Bolt (iii) 200 x 12
(c) Door handle (ii) 100mm
18.1.1: Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details,ying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). ISI approved super ductile TMT Bar (a) From primary producer : TATA / SAIL / Jindal steel / Shyam steel / RINL (i) TMT Corrosion resistant steel (CRS)
18.9.1: Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes , channels , plates etc., including welding , grinding , buffing polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete , i.e. fixing the railing with necessary accessories & stainless steel dash fasteners ,stainless steel bolts etc., of required size , on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in-charge. (For payment, only weight of stainless steel member is be considered.No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered)
19.2: Providing plinth protection with bricks flat laid in cement mortar 1:4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
21.1.1: Providing cast in-situ manually driven reinforced cement concrete piles of using required grade of cement concrete of required bore-diameter, bulb diameter, lengths and with reinforcement as per specifications and drawings. Reinforcement to be measured and paid seperately as per item no. 21.4.1 (d) Pile dia 400 mm with 1000 mm bulb diameter (i) Upto 10 M
21.5.1: Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code, for reinforced cement concrete works in piles including straightening, cleaning, cutting and bending to proper shapes and length as per specifications and drawings. The rings should be welded with vertical reinforcements as per specified IS codes of practice. (Inclusive of lap length, hook, chair, bend, anchor...etc) (C) ISI approved M.S. Rod
22.3.7: Supplying, providing, mixing and laying over waterproofing layers/ coatings with cement mortar screed of average 25mm thick or as per drawings/ requirements in proportion 1:4 (1cement : 4sand) admixed with integral waterproofing admixture Conplast X421IC of Fosroc Chemicals /Rheomac 707 of BASF/Dr. Sealkit Normal Plast of (Asian Chemicals)@ 125ml per bag of cement complete as specified and directed by the Department.
26.1.3: Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. (a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
(CIVIL WORKS) FIRST FLOOR : 2.2.1.: Providing and laying plain/reinforced cement concrete works with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work & reinforcement for reinforced cement concrete works (form work and reinforcement will be measured and paid separately) 1. Using mixture machine ii) In supers structure from plinth level upto 1st floor level. (B) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing the top surface & finishing of nosing.
4.1.8: 112mm thick 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding MS rod/Tor steel of column to be embedded in cement mortar and will be measured and paid separately) a) In cement mortar in proportion 1:4 (1 cement : 4 sand)
3.2.1.1: Providing form work of 12mm thick ply wood board so as togive a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in : Column, pillars, posts & Strut (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face
3.2.1.2: Sides and soffits of beams, beam haunchings , cantilever giders , bressumers , lintels and horizontal ties. (ii) For depth not execcding IDM
3.1.1.5: Formwork Flat surfaces such as soffits of suspended floors , roofs landing , cantilaever slabs chajjas , balconies and like (a) Floors upto 200mm in thickness
3.2.1.8: Staircase with sloping or stepped soffits including risers and stringers but excluding landing.
3.4.1.6: Vertical surface such as walls (any thickness), Lift shafts, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
6.2.2: 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. (A) On rough side (c) In cement mortar 1:5
(B) On fair side (c) In cement mortar 1:5
6.2.1: 10mm thick cement plaster in single coat on fair side of brick/concrete walls for interior plastering upto 3rd floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. (d) In cement mortor 1:6
13.3.5: Providing two coats of J.K. wall putty (white cement based putty for concrete /mortar walls and ceiling both internal And external) after removing all loosely Adhering materials from the wall surface With the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coates is maximum 1.5mm).
13.5.2: Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem “Rakshak” brand of required shade by thinning 11ltr. of paint with 750ml of water to give an even shade after thoroughly brooming the surface to remove all dirt and remains of loose powdered materials as specified and directed by the department. (c) Asian paint / Berger paint / ICI ect.
13.4.7: Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a).Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
13.5.1: Applying one self-priming coat of acrylic emulsion coating of Unicem "Rakshak" brand by thinning 1ltrs of paints with 1ltrs of water over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department.
13.6.5: Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/ Neroalc) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter sand papering and stopping. (i) Surfaces over 100mm in width or girth. (a) enamel paint
13.6.3: Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (b). With ready mixed paint , wood primer (white).
5.7.2.2: Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department). i) Of size 300mmx450mm and above
5.7.2.1: Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) b) Executive range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make i) Of size 800mmx800mm and above
5.5.5: 18 mm thick marble chips skirting or dado rubbed and polish to granolithic finish with under layer 12 mm thick in cement plaster in prop. 1:3 (1 cement :3 coarse sand) and top layer 6 mm thick with marble chips of any colour or combination of colours of 4 mm nominal size laid in cement marble powder mix 3:1( 3 cement : 1 marble powder by weight in proportion of 4:7 (4 cement marble powder mix : 7 marble chips by volume) (a) Pigment of any shade with ordinary cement in top layer only.
5.11.1: Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. 5.11.2: VITRIFIED (i) Normal range (Sizes 300 mm x 300mm and above) Somany made- Durastone (Unpolished heavy duty Vitrified Tiles) (b). Deluxe
5.10.3: Providing polished granite tiles of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) (ii) With White cement
7.10.1: Providing and fixing, in position suspended false ceiling using E-Grid (exposed ceiling suspension 2430 system) of grid size 600mm x 600mm/1200mmx600mm with main runner 38 x 24mm, cross tee 29mm x 24mm & wall angle 24mm x 24mm . Using 4mm/6mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Board as per IS 14862, to be placed in a grid of G.I. system duly suspended with 4mm/6mm dia G.I/M.S bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450mm from the adjacent wall. Flush fitting 1220mm cross tee to be interlocked between main runners @ 610mm c/c, so as to form 600mm x 600mm/1200mmx600mm grid, all complete as per the drawing & directions of engineer-in-charge. (A) Standard Ceilings of Everest make or equivalent as directed by the departement (ii) Using 6 mm thick FC Board
9.1.2: Providing wood work in frame (chowkhats) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (a) With 1st class timber (Bonsun /Sundi)
9.9.3: Providing, fitting and fixing factory made wooden panelled doors with panel inserts of 75mm to 50mm width and 12mm to 20mm thickness,joined together with continous tongue and groove joints glued together with Movicol or other approved adhesive leaving a vertical groove of 7.5mm to 15mm between the inserts,the edges of panel inserts being feather tongue into styles and rails including providing three pairs of oxidised M.S butt hinges (100mm x 75 mm x 3.55mm) and furnishing with moulded timber beading of size 25mm x 15mm around the panels complete as per drawing (moulded timber bead and all fittings except hinges to be paid separately). (b) With 1st class local wood(Hollock / Bola/ Bonsum) (iii) 35 mm thick with panel inserts of 20mm thickness.
11.1.2: Providing, fitting and fixing anodized aluminium sliding windows and ventilators of standard sections approved brand (HINDALCO/NALCO/BALCO/JINDAL/ other equivalent primary producer) without horizontalglazing bars, jointsmitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, Angle cleat, rubber gasket,roller, bolting Device, locking arrangements, servews, etc.as reqd. complete as specified and directed for all levels. (b) 3 Track sliding window (iv) 5mm clear glass
(a) 2 Track sliding window (iv) 5 mm clear glass
11.6.7: Providing , fabrication and fixing of structural glazing made out of coloured Anodised aluminium mother frame 6 nos 1.2m each @ 1.819 Kg/m and subframe of 16 nos 0.60 m each @ 0.31 Kg/m of Jindal or equivalent and 5 mm reflective glass of approved shade. The glass to be pasted using structural selicon (DC 995) and weatherseal silicon to be used (DC 789), the structure complete with all accessories as and where necessary.
10.2: Providing, fitting & fixing plain MS grill of required pattern for windows/ ventilators/fixed glazing & other openings with MS sq bars & flats as per details provided including welding to the frames & finishing with one coat of red oxide primer and two coats of enamel paint. (b) Plain grill. (a) Fixed to wooden Frames.
15.2.1: Supplying , fitting ,fixing anodized aluminium fitting of apprived make , reonably smooth , free from sharp edges and corners , flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodized to bright natural matt & satin finished). (b) Tower Bolt (iii) 200 x 12
(c) Door handle (ii) 100mm
18.1.1: Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details,ying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). ISI approved super ductile TMT Bar (a) From primary producer : TATA / SAIL / Jindal steel / Shyam steel / RINL (i) TMT Corrosion resistant steel (CRS)
18.9.1: Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes , channels , plates etc., including welding , grinding , buffing polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete , i.e. fixing the railing with necessary accessories & stainless steel dash fasteners ,stainless steel bolts etc., of required size , on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in-charge. (For payment, only weight of stainless steel member is be considered.No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered)
22.3.7: Supplying, providing, mixing and laying over waterproofing layers/ coatings with cement mortar screed of average 25mm thick or as per drawings/ requirements in proportion 1:4 (1cement : 4sand) admixed with integral waterproofing admixture Conplast X421IC of Fosroc Chemicals /Rheomac 707 of BASF/Dr. Sealkit Normal Plast of (Asian Chemicals)@ 125ml per bag of cement complete as specified and directed by the Department.
(CIVIL WORKS) SECOND FLOOR : 2.2.1.: Providing and laying plain/reinforced cement concrete works with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work & reinforcement for reinforced cement concrete works (form work and reinforcement will be measured and paid separately) 1. Using mixture machine ii) In supers structure from plinth level upto 1st floor level. (B) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing the top surface & finishing of nosing.
4.1.8: 112mm thick 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding MS rod/Tor steel of column to be embedded in cement mortar and will be measured and paid separately) a) In cement mortar in proportion 1:4 (1 cement : 4 sand)
3.2.1.1: Providing form work of 12mm thick ply wood board so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in : Column, pillars, posts & Strut of Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face
3.2.1.2: Sides and soffits of beams, beam haunchings , cantilever giders , bressumers , lintels and horizontal ties. (a)For depth not exceding 1.0M
3.2.1.3: Formwork Flat surfaces such as soffits of suspended floors , roofs landing , cantilaever slabs chajjas , balconies and like (a) Floor etc up to 200mm in thickness
3.2.1.8: Staircase with sloping or stepped soffits including risers and stringers but excluding landing.
3.2.1.6: Vertical surface such as walls (any thickness), Parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
6.2.2: 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. (A) On rough side (c) In cement mortar 1:5
(B) On fair side (c) In cement mortar 1:5
6.2.1: 10mm thick cement plaster in single coat on fair side of brick/concrete walls for interior plastering upto 3rd floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. (d) In cement mortor 1:6
13.3.5: Providing two coats of J.K. wall putty (white cement based putty for concrete /mortar walls and ceiling both internal And external) after removing all loosely Adhering materials from the wall surface With the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coates is maximum 1.5mm).
13.5.2: Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem “Rakshak” brand of required shade by thinning 11ltr. of paint with 750ml of water to give an even shade after thoroughly brooming the surface to remove all dirt and remains of loose powdered materials as specified and directed by the department. (c) Asian paint / Berger paint / ICI ect.
13.4.7: Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a).Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
13.5.1: Applying one self-priming coat of acrylic emulsion coating of Unicem "Rakshak" brand by thinning 1ltrs of paints with 1ltrs of water over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department.
13.6.5: Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/ Neroalc) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter sand papering and stopping. (i) Surfaces over 100mm in width or girth. (a) enamel paint
13.6.3: Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (b). With ready mixed paint , wood primer (white).
5.7.2.2: Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department). i) Of size 300mmx450mm and above
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 5.7.2.1 (b)(i): 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) b) Executive range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make i) Of size 800mmx800mm and above
5.11.1: Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. 5.11.1 VITRIFIED (i) Normal range (Sizes 300 mm x 300mm and above) Somany made- Durastone (Unpolished heavy duty Vitrified Tiles) (b). Deluxe
5.10.3: Providing polished granite tiles of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) (ii) With White cement
5.5.5: 18 mm thick marble chips skirting or dado rubbed and polish to granolithic finish with under layer 12 mm thick in cement plaster in prop. 1:3 (1 cement :3 coarse sand) and top layer 6 mm thick with marble chips of any colour or combination of colours of 4 mm nominal size laid in cement marble powder mix 3:1( 3 cement : 1 marble powder by weight in proportion of 4:7 (4 cement marble powder mix : 7 marble chips by volume) (a) Pigment of any shade with ordinary cement in top layer only.
7.10.1: Providing and fixing, in position suspended false ceiling using E-Grid (exposed ceiling suspension 2430 system) of grid size 600mm x 600mm/1200mmx600mm with main runner 38 x 24mm, cross tee 29mm x 24mm & wall angle 24mm x 24mm . Using 4mm/6mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Board as per IS 14862, to be placed in a grid of G.I. system duly suspended with 4mm/6mm dia G.I/M.S bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450mm from the adjacent wall. Flush fitting 1220mm cross tee to be interlocked between main runners @ 610mm c/c, so as to form 600mm x 600mm/1200mmx600mm grid, all complete as per the drawing & directions of engineer-in-charge. (A) Standard Ceilings of Everest make or equivalent as directed by the departement (ii) Using 6 mm thick FC Board
9.1.2: Providing wood work in frame (chowkhats) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (a) With 1st class timber (Bonsun /Sundi)
9.9.3: Providing, fitting and fixing factory made wooden panelled doors with panel inserts of 75mm to 50mm width and 12mm to 20mm thickness,joined together with continous tongue and groove joints glued together with Movicol or other approved adhesive leaving a vertical groove of 7.5mm to 15mm between the inserts,the edges of panel inserts being feather tongue into styles and rails including providing three pairs of oxidised M.S butt hinges (100mm x 75 mm x 3.55mm) and furnishing with moulded timber beading of size 25mm x 15mm around the panels complete as per drawing (moulded timber bead and all fittings except hinges to be paid separately). (b) With 1st class local wood(Hollock / Bola/ Bonsum) (iii) 35 mm thick with panel inserts of 20mm thickness.
11.1.2: Providing, fitting and fixing anodized aluminium sliding windows and ventilators of standard sections approved brand (HINDALCO/NALCO/BALCO/JINDAL/ other equivalent primary producer) without horizontalglazing bars, jointsmitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, Angle cleat, rubber gasket,roller, bolting Device, locking arrangements, servews, etc.as reqd. complete as specified and directed for all levels. (b) 3 Track sliding window (iv) 5mm clear glass
(a) 2 Track sliding window (iv) 5 mm clear glass
11.6.7: Providing , fabrication and fixing of structural glazing made out of coloured Anodised aluminium mother frame 6 nos 1.2m each @ 1.819 Kg/m and subframe of 16 nos 0.60 m each @ 0.31 Kg/m of Jindal or equivalent and 5 mm reflective glass of approved shade. The glass to be pasted using structural selicon (DC 995) and weatherseal silicon to be used (DC 789), the structure complete with all accessories as and where necessary.
10.2: Providing, fitting & fixing plain MS grill of required pattern for windows/ ventilators/fixed glazing & other openings with MS sq bars & flats as per details provided including welding to the frames & finishing with one coat of red oxide primer and two coats of enamel paint. (b) Plain grill. (a) Fixed to wooden Frames.
15.2.1: Supplying , fitting ,fixing anodized aluminium fitting of apprived make , reonably smooth , free from sharp edges and corners , flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodized to bright natural matt & satin finished). (b) Tower Bolt (iii) 200 x 12
(c) Door handle (ii) 100mm
18.1.1: Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details,ying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). ISI approved super ductile TMT Bar (a) From primary producer : TATA / SAIL / Jindal steel / Shyam steel / RINL (i) TMT Corrosion resistant steel (CRS)
18.9.1: Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes , channels , plates etc., including welding , grinding , buffing polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete , i.e. fixing the railing with necessary accessories & stainless steel dash fasteners ,stainless steel bolts etc., of required size , on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in-charge. (For payment, only weight of stainless steel member is be considered.No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered)
22.3.7: Supplying, providing, mixing and laying over waterproofing layers/ coatings with cement mortar screed of average 25mm thick or as per drawings/ requirements in proportion 1:4 (1cement : 4sand) admixed with integral waterproofing admixture Conplast X421IC of Fosroc Chemicals /Rheomac 707 of BASF/Dr. Sealkit Normal Plast of (Asian Chemicals)@ 125ml per bag of cement complete as specified and directed by the Department.
TERRACE FLOOR: 2.2.1.: Providing and laying plain/reinforced cement concrete works with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work & reinforcement for reinforced cement concrete works (form work and reinforcement will be measured and paid separately) 1. Using mixture machine ii) In supers structure from plinth level upto 1st floor level. (B) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing the top surface & finishing of nosing.
4.1.8: 112mm thick 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding MS rod/Tor steel of column to be embedded in cement mortar and will be measured and paid separately) a) In cement mortar in proportion 1:4 (1 cement : 4 sand)
3.1.1.3: Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in : Column, pillars, posts & Strut (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face (ii) Using 25mm thick plank
3.2.1.2 Sides and soffits of beams, beam haunchings , cantilever giders , bressumers , lintels and horizontal ties. ii) Using 25mm thick plank
3.2.1.3 Formwork Flat surfaces such as soffits of suspended floors , roofs landing , cantilaever slabs chajjas , balconies and like ii) 25mm thk. Plank
3.2.1.8: Staircase with sloping or stepped soffits including risers and stringers but excluding landing.
6.2.2: 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. (A) On rough side (c) In cement mortar 1:5
(B) On fair side (c) In cement mortar 1:5
6.2.1: 10mm thick cement plaster in single coat on fair side of brick/concrete walls for interior plastering upto 3rd floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. (d) In cement mortor 1:6
13.3.5: Providing two coats of J.K. wall putty (white cement based putty for concrete /mortar walls and ceiling both internal And external) after removing all loosely Adhering materials from the wall surface With the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coates is maximum 1.5mm).
13.5.2: Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem “Rakshak” brand of required shade by thinning 11ltr. of paint with 750ml of water to give an even shade after thoroughly brooming the surface to remove all dirt and remains of loose powdered materials as specified and directed by the department. (c) Asian paint / Berger paint / ICI ect.
13.4.7: Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a).Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
13.5.1: Applying one self-priming coat of acrylic emulsion coating of Unicem "Rakshak" brand by thinning 1ltrs of paints with 1ltrs of water over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department.
13.6.5: Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/ Neroalc) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter sand papering and stopping. (i) Surfaces over 100mm in width or girth. (a) enamel paint
13.6.3: Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (b). With ready mixed paint , wood primer (white).
5.1.3: 40 mm thick cement concrete floor consisting of 25 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 12.5 mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) finished with a floating coat of neat cement finish using cement slurry for bond @ 2.75 kg. per square metre of floor area , wearing layer is to be laid in panels including curing etc. complete as directed.
5.1.2: 25 mm thick cement concrete topping 1:2:4 (1cement : 2 coarse sand : 4 coarse aggregate of 12 mm nominal size) finished with a floating coat of neat cement finish to be laid in panels including curing complete as directed.
5.8.1: Kota-stone slab flooring of 18 mm thick over 20mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. (1) 550mm x 550mm
5.5.5: 18 mm thick marble chips skirting or dado rubbed and polish to granolithic finish with under layer 12 mm thick in cement plaster in prop. 1:3 (1 cement :3 coarse sand) and top layer 6 mm thick with marble chips of any colour or combination of colours of 4 mm nominal size laid in cement marble powder mix 3:1( 3 cement : 1 marble powder by weight in proportion of 4:7 (4 cement marble powder mix : 7 marble chips by volume) (a) Pigment of any shade with ordinary cement in top layer only.
9.1.2: Providing wood work in frame (chowkhats) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (a) With 1st class timber (Bonsun /Sundi)
9.9.3: Providing, fitting and fixing factory made wooden panelled doors with panel inserts of 75mm to 50mm width and 12mm to 20mm thickness,joined together with continous tongue and groove joints glued together with Movicol or other approved adhesive leaving a vertical groove of 7.5mm to 15mm between the inserts,the edges of panel inserts being feather tongue into styles and rails including providing three pairs of oxidised M.S butt hinges (100mm x 75 mm x 3.55mm) and furnishing with moulded timber beading of size 25mm x 15mm around the panels complete as per drawing (moulded timber bead and all fittings except hinges to be paid separately). (b) With 1st class local wood(Hollock / Bola/ Bonsum) (iii) 35 mm thick with panel inserts of 20mm thickness.
11.6.7: Providing , fabrication and fixing of structural glazing made out of coloured Anodised aluminium mother frame 6 nos 1.2m each @ 1.819 Kg/m and subframe of 16 nos 0.60 m each @ 0.31 Kg/m of Jindal or equivalent and 5 mm reflective glass of approved shade. The glass to be pasted using structural selicon (DC 995) and weatherseal silicon to be used (DC 789), the structure complete with all accessories as and where necessary.
10.2: Providing, fitting & fixing plain MS grill of required pattern for windows/ ventilators/fixed glazing & other openings with MS sq bars & flats as per details provided including welding to the frames & finishing with one coat of red oxide primer and two coats of enamel paint. (b) Plain grill. (a) Fixed to wooden Frames.
15.2.1: Supplying , fitting ,fixing anodized aluminium fitting of apprived make , reonably smooth , free from sharp edges and corners , flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodized to bright natural matt & satin finished). (b) Tower Bolt (iii) 200 x 12
(c) Door handle (ii) 100mm
18.9.2: Providing and fixing M.S Tube hand rail of approved size by welding etc. to steel ladder railing , balcony railing , staircase railing and similar works , including applying priming coat of approved steel primer complete as specified and directed by department.
18.1.1: Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details,ying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). ISI approved super ductile TMT Bar (a) From primary producer : TATA / SAIL / Jindal steel / Shyam steel / RINL (i) TMT Corrosion resistant steel (CRS)
18.9.1: Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes , channels , plates etc., including welding , grinding , buffing polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete , i.e. fixing the railing with necessary accessories & stainless steel dash fasteners ,stainless steel bolts etc., of required size , on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in-charge. (For payment, only weight of stainless steel member is be considered.No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered)
22.3.9: Providing and applying over roof/ raft slab, two coats of waterproofing slurry prepared with cement, fine sand in prop 1:1 admixed with modified acrylic polymer like Cemflex of Sika India Ltd./Dr. Sealkit Sealcrete (Asian Chemicals),/ RHEOMIX 131 OF BASF by brush @ 0.25% of cement-sand mixture (by weight) after proper surface preparation (surface preparation including thorough cleaning of surface to be measured and paid separately) as specified & directed by the Department complete.
SANITARY : 1.2: Providing fitting and fixing Vitreous china Dual Flush/ wall hang water closet (European type W.C pan 400mm high) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) (a) Parryware Make a) White (i)Universal Closet S Trap (Cat No . C0271) (Anglo Indian) (inclusive of seat cover)
1.6: Supplying, fiting and fixing concealed cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) Parryware make
1.7: Providing fitting and fixing vitreous china flat back type lipped front urinal basin of with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. B) Hindware make a) White (v)Senso Urinal (Cat. No.60018)
1.11: Supplying fiting and fixing vitreous china division plate including fitting and fixing compete as directed and specified. (ii) Hindware Make (a) White (ii) New Division Plate (Cat. No.61005)
1.13: Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) 1.13.2: Basin (without pedestal) (B) Hindware Make (a) White (ii) Standard 630 x 450 (Cat. No.10001)
1.15: Providing fitting & fixing stainless steel kitchen sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately (A) Parryware Make (i) Single Bowl with Veg Bowl & Drain Board (400 x 200) Flat Edge- Glossy (Cat.No.C8545)
1.19: Providing fitting and fixing Decorative Mirror complete as directed and specified. (B) Jaquar Make (a) Double Arm Wall Mounted reversible plain / Magnifying (3X) Pivotal Mirror (Cat. No.ACN-1193N)
1.22 Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified. (i) Jaquar Make (a) Continental (Cat.No.ACN-1331N)
1.24: Providing, fitting and fixing CP towel rail complete as directed and specified. (a) Jaquar make (i) Continental 300mm for wash basin (Cat.No. ACN-1101N)
1.32: Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified. (a) Jaquar Make (i) 32mm (HT/FT) (Cat.No.ALD-705 / 709)
1.33: Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified. (a) Jaquar make (i) Bottle trap (with internal partition) 32mm size with 250mm long wall connection pipe (Cat.No. ALD-769)
1.36.1: Supplying, fitting and fixing I.S.I marked or similar approved H.C.I pipe including bolts and nuts and other fittings as required and complete at all levels including below G.L as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 100mm dia.
1.36.2: Supplying,fitting and fixing H.C.I plain bend including bolts and nuts and other fittings as required complete at all levels including below G.L as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 100mm dia.
1.36.3: Supplying, fitting and fixing H.C.I bend with door including bolts and nuts and other fittings as required complete at all levels including below G.L as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 100mm dia.
1.36.4: Supplying, fitting and fixing H.C.I plain single equal junction/plain tee including bolts and nuts and other fittings as required complete at all levels including below G.L as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 100mm dia.
1.37.1: Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
(ii) 75mm dia.
1.37.2: Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm dia.
(ii)75mm dia.
1.37.3: Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm dia.
(ii)75mm dia.
1.37.5: Supplying fitting and fixing PVC plain single tee of (Supreme/ Prince ) or other ISI apporoved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm dia.
(ii)75mm dia.
1.37.6: Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm dia.
(ii) 75mm dia.
1.37.14: Supplying fiting and fixing PVC reducer of (Supreme /prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm x75mm
1.39: Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. (ii) 110mm dia. PVC cowel of ISI make
1.40: Providing fiting & fixing C.I. Grating to the floors complete as directed and specified. (a) 110mm dia
1.51: Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C plain sheet above brick bat filling complete as directed.(sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table)
WATER SUPPLY: 3.1.1: Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (A) Exposed on walls a) 50 mm dia (Medium) i) Using Tata make
(B) Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure. d) 25 mm dia (Medium) i) Using Tata make
3.2.1: Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) (II) Jaquare make (a)Continental /Clarion (i)Standard
3.3.1: Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (i)15mm dia
3.5.1: Supplying and fitting fixing C.P pillar coak of 15mm dia of approved brand as specified and directed. (a)Continental (i) Jaquar Make
Supplying and fitting fixing C.P Sink coak of 15mm dia of approved brand as specified and directed. (a)Continental (i) Jaquar Make
3.8.2: Supplying fitting and fixing Chrome Plated (C.P.) shower 15mm dia. Of approved brand as directed and specified. (Pipes will be measured and paid separately) (III) Jaquar make a) Continental (ii) Shower arm 190mm long heavy casted body with wall flange
3.17.1: Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. c) 25 mm dia.
3.17.2: Supplying and fitting ball valve as specified and directed.. a) 25 mm dia. (gun metal)
3.17.3: Supplying fitting and fixing gun metal check valve including necessary threads to pipes. b) 40 mm dia (Heavy type)
WATER TANK: Supplying and placing plastic cylindrical vertical claused top (PCVC) TANK TANK OF Sintex / Polycon / make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes. (i) 2000 lit. Capacity
BORING: 5.3.2: Supplying fitting and fixing Hand pump for 40 mm dia tube well with all accessories complte as directed. (ii) Mayur
5.3.4: Labour for boring hole for inserting tube well pipes through different soil / rock media including hire charges of drill pipes , scaffolding , tools and plants as necessary and taking out the same and lowering pipes , fittings complete as directed by the Department. (iv) Bore hole of 150mm diameter
5.3.5: Supplying , fitting and fixing pipes plain / bevel ended for casing , conforming to relevant IS codes of practice including supplying and fitting of tube well accessories , lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt , dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. II. PVC PIPE SUPREME / PRINCE / FUSION / SFMC BRAND (vii) 160mm dismeter
5.3.6: Supplying , fitting and fixing suction pipes plain / bevel ended , conforming to relevant IS codes of practice including supplying and fitting of accessories , lowering of assembly pipes concentrically in the casing pipes complete as directed. B. PVC PIPE (vii) 110mm dismeter
5.3.9: Supplying fitting and fixing ISI approved PVC filter 3.00 metre long.
5.3.11: Supplying fitting and fixing check value (non return value) including thread to pipes. (vi) 80mm diameter
5.3.13: Flushing , clearing , washing and watering of the tube well.
IRON REMOVAL FILTERS: Taurus make FRP composite Structural vessel Iron Removal Filters of 100% rustproof vessels complete with Top & Bottom Strainers , Multiport Valves , Quality filter media - e . G Treated sand , Mno2 , Barakar Sand Gravels & pebbles. ISO , NSF certified. (I) 1000 liters capacity
SEPTIC TANK: 6.2.1: Supplying and placing ferrocement septic tanks of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soling and 75mm 1:3:6 P.C.C Baffle wall , inlet and outlet etc. are provided at suitable points complete as directed (ix) 250 users
FIRE EXTINGUISHERS: Providing and fixing portable fire extinguisher water type (gas cartridge) with cylinder fully charged of 9 litres capacity complete with standard discharged valve with tube CI bracket for wall mounting etc. conforming to IS: 940.
Providing and fixing portable fire extinguisher, dry powder type (gas cartridge) with cylinder initially fully charged with dry powder (ABC type) of 5 Kg. Complete with standard discharge valve with tube, CI bracket for wall mounting etc. conforming to IS: 2171.
Providing and fixing portable fire extinguisher carbon dioxide type with cylinder initially fully charged with CO2 gas of 4.5 Kg. Capacity, complete with discharge valve, dishcarge tube, horn, CI bracket for wall mounting etc. conforming to IS: 2878.
Providing and fixing portable fire extinguisher mechanical foam type with cylinder initially fully charged with foam compound of 9 litres capacity, complete with standard discharge valve with tube CI bracket for wall mounting etc. conforming to IS: 10204.
FURNITURE (For GROUND FLOOR):: TABLE Main Table: 1500 x 750 x 750 Side Table: 1350 x 450 x 750 Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support: 25mm thick Gable Ends.18mm thick PLT Modesty Panel of 450 mm ht is considered. Wire Management: 65mm Dia Wire Manager Grommet Mobile Pedestal MOBILE PEDESTAL MODEL: V-2D1F Size: 400 W x 450 D x 640 HT Make: Featherlite
MAIN CHAIR MODEL: CONTACT PROJECT MBGS FXD ARMS Contact Project Medium Mesh Back Chair Single Lock Synchro Mechanism Fixed ArmsFixed Arms Nylon Base Make: Featherlite
LAB INCHARGE TABLE Main Table: 1500 x 750 x 750 Side Table: 1350 x 450 x 750 Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support: 25mm thick Gable Ends.18mm thick PLT Modesty Panel of 450 mm ht is considered. Wire Management: 65mm Dia Wire Manager Grommet Mobile Pedestal MOBILE PEDESTAL MODEL: V-2D1F Size: 400 W x 450 D x 640 HT Make: Featherlite
LAB INCHARGE CHAIR MODEL: ASTRO HB Astro High Back Chair Single Lock Synchro Mechanism Adjustable Lumbar Support One Way Adjustable Arms (Height) Headrest Nylon Base Make: Featherlite
CARE TAKER BED Model: Optima Single Bed - code 359 Size: 1060W x 2080D x 785HT Make: Zuari
Bed side Table Size: 445 x 395 x 460 ht Make: Zuari
(for FIRST FLOOR) EXECUTIVE ENGINEER ROOM Main Table - Size:1800 x 900 x 750 Side Table: 1350 x 450 x 750 mm ht Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support: 25mm thick Gable Ends.18mm thick PLT Modesty Panel of 450 mm ht is considered. Wire Management: 65mm Dia Wire Manager Grommet Mobile Pedestal Back Storage (LHC): 1500 x 450 x 750 mm ht Storage : Storage is made of 18mm PLB with openable shutters, adjustable shelves, auto closing hinges, locking mechanism and recessed handles. Make: Featherlite
Main Chair MODEL: ASTRO HB Astro High Back Chair Single lock Synchro Mechanism Adjustable Lumbar Support Obe Way Adjustable Arms (Height) Nylon Base Make: Featherlite
3 seater Sofa MODEL: 238-3S Sofa Three Seater - Leatherette Make: Featherlite
Centre Table MODEL: 610- FL Rectangular Table Chrome Frame with Glass Top Size: 1200 X 600mm Make: Featherlite
Visitor Chair (EXECUTIVE ENGINEER) MODEL: FP Invention MB - Height Adj Arms Quotient Medium Back Chair with Multilock Mechanism , Gaslift & Two Way Adjustable Arms (Height & Swivel) with Chrome Base - Leatherette Seat & Back Make: Featherlite
OFFICE ROOM Main Table size: 1200 x 750 x 750 mm ht Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support: 25mm thick Gable Ends.18mm thick PLT Modesty Panel of 450 mm ht is considered. Wire Management: 300mm Aluminium Flip up Wire entry cover Mobile Pedestal Size: 400 W x 450 D x 640 HT 8 mm colour glass Screen : 1050 x 300 mm ht Make: Featherlite
Main Chair MODEL: ASTRO HB AstroHigh Back Chair Single Lock Synchro Mechanism Adjustable Lumbar Support One Way Adjustable Arms (Height) Nylon Base Make: Featherlite
Conference Hall Model: Zen Conference Table Size: 3000 x 1200 x 750 mm ht Specifications: Table Top: 40mm thick pre laminated particle board with matching PVC edge lipping Support: 25mm thick pe laminated particle board with matching PVC edge lipping Modesty Panel: 1200 x 450HT- 18mm thick pre laminated particle board modesty panel of 450mm Ht. Wire Management: 2 no of 450mm aluminium flip up, provision to mount switches and sockets on PVC cable dump and Vertical wire entry cover for wire uptake from floor to cable dump Make: Featherlite
Low Height Storage Model: Zen Size: 3000 x 450 x 700 mm ht Back panel 3600 L x 900 ht x 25 mm Specifications: Table & Back: 25mm thick pre laminated particle board with matching PVC edge lipping. Sides & Shutter: 18mm thick pre laminated particle board. Handle: Recessed handle in anodised finish. Hardware: Door closing hinges, mini-fix, levellers & locks, etc. Make: Featherlite
Conference Chair Model: Opus MB Self calibrating multilock mechanism Asynchronous adjustable lumbar support Height Adjustable arms Nylon base Make: Featherlite
Record Room Full Height Cabinet (Record Room) Size: 2400 x 450 x 2100 mm ht Specification: Storage : Storage is made of 18mm PLB with openable shutters, adjustable shelves, auto closing hinges, locking mechanism and recessed handles. Make: Featherlite
CASHIER 2 seater Linear nin sharing workstations Size: 1200 x 750 x 750 mm Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support: 25mm thick Gable Ends.18mm thick PLT Modesty Panel of 450 mm ht is considered. Wire Management: 300 mm flipup with 2 no wire entry cover Main Screen: 8 mm colour glass Screen : 1050 x 300 mm ht Return Screen: 8 mm colour glass Screen : 525 x 300 mm ht Mobile Pedestal MODEL: V-2D1F Size: 400 W x 450 D x 640 HT Make: Featherlite
Main Chair (CASHIER) MODEL: CONTACT PROJECT MBGS FXD ARMS Contact Project Medium Mesh Back Chair Single Lock Synchro Mechanism Fixed Arms Nylon Base Make: Featherlite
Low Height Cabinet (CASHIER) 3000 x 450 x 750 mm ht Specification: Storage : Storage is made of 18mm PLB with openable shutters, adjustable shelves, auto closing hinges, locking mechanism and recessed handles. Make: Featherlite
ACCOUNT OFFICER ROOM Main Table: Size: 1800 x 900 x 750 mm ht Side Table : 1050 x 450 x 750 mm ht Specification: Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support: 25mm thick Gable Ends.18mm thick PLT Modesty Panel of 450 mm ht is considered. Wire Management: 65mm Dia Wire Manager Grommet Mobile Pedestal MODEL: V-2D1F Size: 400 W x 450 D x 640 HT Make: Featherlite
Main chiar (ACCOUNT OFFICER) MODEL: ASTRO HB Astro High Back Chair Single Lock Synchro Mechanism Adjustable Lumbar Support One Way Adjustable Arms (Height) Headrest Nylon Base Make: Featherlite
Visitor Chair (ACCOUNT OFFICER) Model: Smart MB Smart Mesh Back Cushioned Seat Tilting Mechanism Fixed Arms Nylon Base Make: Featherlite
EXECUTIVE ENGINEER REST ROOM Bed Room Double Bed Model: Optima Code- 658 Size: 1920W x 2080D x 810HT Make: Zuari
Bedside Table Model: Optima Code- 140 Make: Zuari
PANTRY Room Dining Table Model: Viola Code-732929 Size: 900W x 1500D Make: zuari
Dining Chair Model: Viola Code-732914 Size:480W x 535D x 930Ht x 450 SH Make: Zuari
SECOND FLOOR IT ROOM Main Table - Size:1500 x 900 x 750 Side Table: 900 x 450 x 750 mm ht Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support: 25mm thick Gable Ends.18mm thick PLT Modesty Panel of 450 mm ht is considered. Wire Management: 65mm Dia Wire Manager Grommet Mobile Pedestal MODEL: V-2D1F Size: 400 W x 450 D x 640 HT Make: Featherlite
Main Chair MODEL: ASTRO MB Astro Medium Back Chair Single Lock Synchro Mechanism Adjustable Lumbar Support One Way Adjustable Arms (Height) Nylon Base Make: Featherlite
Visitor Chair Model: Smart MB Smart Mesh Back Cushioned Seat Tilting Mechanism Fixed Arms Nylon Base Make: Featherlite
ASSISTANT EXECUTIVE ENGINEER ROOM Main Table - Size:1800 x 900 x 750 Side Table: 1350 x 450 x 750 mm ht Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support: 25mm thick Gable Ends.18mm thick PLT Modesty Panel of 450 mm ht is considered. Wire Management: 65mm Dia Wire Manager Grommet Mobile Pedestal Back Storage (LHC): 1500 x 450 x 750 mm ht Storage : Storage is made of 18mm PLB with openable shutters, adjustable shelves, auto closing hinges, locking mechanism and recessed handles. Make: Featherlite
Main Chair MODEL: ASTRO HB AstroHigh Back Chair Single Lock Synchro Mechanism Adjustable Lumbar Support One Way Adjustable Arms (Height) Nylon Base Make: Featherlite
3 seater Sofa MODEL: 238-3S Sofa Three Seater - Leatherette Make: Featherlite
Centre Table MODEL: 610 - FL Rectangular Table Chrome Frame with Glass Top Size: 1200 x 600mm Make: Featherlite
Visitor Chair (ASSISTANT EXECUTIVE ENGINEER) MODEL: FP Invention MB - Height Adj Arms Quotient Medium Back Chair with Multilock Mechanism , Gaslift & Two Way Adjustable Arms (Height & Swivel) with Chrome Base - Leatherette Seat & Back Make: Featherlite
ASSISTANT ENGINEER ROOM Main Table - Size:1500 x 900 x 750 Side Table: 1350 x 450 x 750 mm ht Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support: 25mm thick Gable Ends.18mm thick PLT Modesty Panel of 450 mm ht is considered. Wire Management: 65mm Dia Wire Manager Grommet Mobile Pedestal MODEL: V-2D1F Size: 400 W x 450 D x 640 HT Make: Featherlite
Low height Storage 2700 x 450 x 750 mm ht Storage : Storage is made of 18mm PLB with openable shutters, adjustable shelves, auto closing hinges, locking mechanism and recessed handles. Make: Featherlite
Main chiar MODEL: ASTRO HB Astro High Back Chair Single Lock Synchro Mechanism Adjustable Lumbar Support One Way Adjustable Arms (Height) Headrest Nylon Base Make: Featherlite
Visitor Chair Model: Smart MB Smart Mesh Back Cushioned Seat Tilting Mechanism Fixed Arms Nylon Base
OFFICE ROOM Main Table size: 1200 x 750 x 750 mm ht Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support: 25mm thick Gable Ends.18mm thick PLT Modesty Panel of 450 mm ht is considered. Wire Management: 300mm Aluminium Flip up Wire entry cover Mobile Pedestal MODEL: V-2D1F Size: 400 W x 450 D x 640 HT 8 mm colour glass Screen : 1050 x 300 mm ht Make: Featherlite
Main Chair MODEL: CONTACT PROJECT MBGS FXD ARMS Contact Project Medium Mesh Back Chair Single Lock Synchro Mechanism Fixed Arms Nylon Base Make: Featherlite
LANDSCAPING: 20.3: Supplying and planting of terrestrial orchids with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned) (A) With Aeirides (I) Using earthen pot of 30 cm dia.
20.7: Supplying and planting of cactus in required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, sand, cow-dung, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned) (A) With Peanut Cactus / Rat tail Cactus (I) Using earthen pot of 30 cm dia.
INTERNAL ELECTRICAL: Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.1: Short point up to 3.00 metre. length.
2.1.2: Medium point up to 6.00 metre. Length.
2.1.3: Long point up to 10.00 metre. Length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. 2.2.2: Medium point up to 6.00 metre. Length.
2.2.3: Long point up to 10.00 metre. Length.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt./ Havells make), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) 2.4.2: Extra long point up to 20.00 metre. Length.
2.4.3: Extra long point up to 25.00 metre. Length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. 2.7.1: With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
2.8.2: With 3 x 4 sq. mm. + earth continuity with 2x 2.5 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
2.8.3: With 3 x 6 sq. mm. + earth continuity with2x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
2.8.4: With 3 x 10 sq. mm. + earth continuity with2x 6 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 32.5.3.4: 70.00 Sq.mm 3 & 1 / 2 Core U.G cable in 50mm dia medium duty G.I pipe
32.1.3.1: 25.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.8.1: ABB, Schneider MG, legrand, Hager make) 15.8.1.2: 6 way TPN (4+18) double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.1.1: B Series (Schneider MG, legrand, Hager make) 16.1.1.1: 6 to 32A
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.6.1: B Series (Schneider MG, legrand, Hager make) 16.6.1.3: 63A
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. SB. 8.13.2 3 module type Metal
SB. 8.13.4 : 6 module type Metal
SB. 8.13.5: 8 module type Metal
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. SB. 8.14.3: 3 module
SB. 8.14.5: 6 module
SB. 8.14.6: 8 module
SB. 8.22: Supplying with fitting fixing of 6 amp one way modular clip in bell push MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
SB 8.8: Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
SB. 8.24: Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
8.15: Supplying including fitting and fixing of TV SOCKET, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
22.8: Supply, installation & testing of G.I. earth station with perforated 50 mm dia and 3.00 Metre long heady duty G.I. pipe with necessary 50 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 65 mmx50 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt . 22.12 Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
22.1: Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx3 mm copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
22.18: Supplying & laying of 6 SWG G.I.. earth drawn through 15 mm dia. Medium quality G.I. pipe from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
22.25: Supplying & laying of 25x5 mm size Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of Brass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
11.32: Supplying and fixing of Call bell ( Buzzer ) including 5/ 6 amp capacity button piano type bell push switch including connection as approved by the Deptt.)as required.
Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. 27.1.3: Premium model 1400 mm Sweep. (ORIENT PSPO make) /Premium model 1400 mm Sweep SS-390 Deco. Havells make)
27.4: Supplying including fitting fixing of following A.C. Wall fan in the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.
27.6: Supplying fitting and fixing of ceiling fan regulator including connections etc. complete as required. 27.6.2: Electronic type
27.4.1: (CROMPTON /ORIENT/Havells/USHA or equivalent make) 27.2.1.2: Exhaust Fan Power Flow 225 mm sweep (ORIENT make)
Supplying and fixing of polished Brass Bracket of 18 S.W.G, 25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required With LED lamp(15W)
Surface mounting CFL luminaires plastic housing wired with ballast for mirror lighting
29.1: Supplying with installation , testing and commissioning of Hi - wall 3STAR rating , non ducted split type air conditioner of the following capacity with cordless remote complete with indoor and outdoor unit , copper pipe and electrical connection up to 5m between the room unit and out door unit as approved by the Deptt. and as directed by the Department. 29.2.4.2: Blue Star make Model 3HW24SVB1
30.11: Supplying with fitting and fixing single phase D.O.L starter of the following specification complete including making necessary connection as approved , specified and directed by the Deptt. 30.11.3: Overload relay range 8.9 - 13.5 / 6 amps for 5.5 KW
31.1: Supplying with fitting and fixing Voltage Stabilizer of the following specification complete including making necessary connection as approved , specified and directed by the Deptt. (SKYLAND / Vee - Dee / V GUARD / VERTEX / INDO / VENUS make). 31.1.7: 4.0 KVA Automatic input 90 - 280 V out put 200 - 240V
36.3: Supplying and erection PSC pole 9.75 metre long, the pole is to be erection in 1:3:6 plain cement concrete foundation of size 1.50 m x 0.45 m x 0.45m having P.C.C base foundation 15 cm x 60 cm x 60cm including edge brick soiling and plastering above G.L. portion (0.30 metre complete with excavation of earth, handling of Surplus Soil, debris etc. to the proper place and refilling etc. as specified and as directed by the department.
36.5: Supplying and erection of H.T. stay set complete (Galvanize with 19mm dia x1.8m long stay rod anchor plate of size 30cm x 30cm x6.4 mm thimble stay clamps tube buckle (19mmx 60c 7/3.15 mm dia G.I stay and strain insulation etc. in cement concrete 1:3:6:(1Cement:3Course sand:6graded stone aggregate 40mm nominal size foundation including excavation and refilling etc. as required and as directed by the department.
36.9: Supplying and fitting fixing of 11 KV T Cross arm complete with clamps ,blots, nuts etc. as required and as directed by the department.
36.11: Supplying and fitting fixing of galvanised channel of 100 mm x 50 mm x 65 x 2200 mm long complete with clamps ,blots, nuts etc. as required and as directed by the department.
36.14: Supplying and erection of 11 KV Pin insulator (Poly) with G.I.pin, blots and nuts coach screw etc. as required and as directed by the department.
36.16: Supplying and erection of 11 KV Disc insulator (Poly) 45 KN with hard ware fittings etc. as required and as directed by the department.
36.29: Supplying and string up AAAC Rabbit conductor in the existing P.S.C./ M.S/ Galvanized pole with binding etc. as required and as directed by the department.
36.34.14: 410 SP 66 Length of pole = 12.00 metre., Length of sections, Bottom = 5.80 M, Middle = 3.10 M, Top = 3.10 M, Out side dia. & Thickness Bottom = 219.10 x 5.60 mm, Middle =193.7 x 4.85 mm, Top =165.10 x 4.50 mm
36.7: Supplying and fitting fixing of galvanised channel of 75 mm x 40 mm x 65 x 2200 mm long complete with clamps ,blots, nuts etc. as required and as directed by the department.
36.11: Supplying and fitting fixing of galvanised channel of 100 mm x 50 mm x 65 x 2200 mm long complete with clamps ,blots, nuts etc. as required and as directed by the department.
36.25: Supplying and fitting fixing pole clamp complete as required and as directed by the department.
36.16: Supplying and erection of 11 KV Disc insulator (Poly) 45 KN with hard ware fittings etc. as required and as directed by the department.
36.14: Supplying and erection of 11 KV Pin insulator (Poly) with G.I.pin, blots and nuts coach screw etc. as required and as directed by the department.
36.23: Supplying and fixing of 11 KV 150 A D.O. fuse set complete as required and as directed by the department.
36.24: Supplying and fixing of 11 KV 5 KA Lighting arrestor (Poly) set complete as required and as directed by the department.
36.22: Supplying and fixing of 11 KV 400 A Gang operated switch with all accessories complete as required and as directed by the department.
36.3: Supplying and string up AAAC Racoon conductor in the existing P.S.C./ M.S/ Galvanized pole with binding etc. as required and as directed by the department. Directed by the department.
36.32: Supplying including installation of 4' dia. C.I. earth pipe complete as required and as directed by the department.
36.33: Supplying and fitting fixing of H.T. danger plate complete as required and as directed by the department.
36.42: Supplying including installation of 11KV CT/PT combine metering system complete as required and as directed by the department. (Or as per APDCL)
22.15: Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
32.2.1.2: 4x240.00 Sq. mm. 1 Core armoured U.G. cable
G.I nut bolt
Supplying, installation testing and commissioning of the following rating copper wound indoor / out door type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVA star rating up to 5 star, above 200KVA as per CEA guidelines for losses along with LV enclosure. 35.1.5: 200 KVA,50Hz.11/0.433 KV. Oil filled transformer with Off Circuit tap change.
Load security to APDCL,approval from State Licensing Board(Liasoning)
Supplying including installation, testing and commissioning of Air/Water Cooled Diesel Generator set coupled to suitable alternator of 220/415 V, AC, 1/3-Phase 0.8 p.f. mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) AMF Control Panel.5) Suitable batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the Technical Specification.. as per manufacturer. (RANGE FROM 5 KVA TO 625 KV . Kirloskar green/bliss, Leyland, Volvo Penta, Perkinson, Mahindra, Greaves, Escort engine and Kirloskar, Stamford, Leroy somer or equivalent alternator. 41.2.1.1: 40-1 -3130x1100x1680- 1440 Kg- W/C
LIFT : Supplying installation, testing and commissioning of Passenger Elevator(KONE make for 3stop(544 K 8 persons) having contract speed of 0.65 Metre/Sec(approx.)mps serving different floor in the existing lift shaft as per detailed specification enclosed and as under Location of the lift- 1.Type & Capacity-Passenger-08 Persons-544Kg. 2.Speed- 0.63 Metre./Sec (approx.) 3.Type of Drive- Variable Voltage Variable Frequency Drive with Microprocessor based Simplex Down Collective Control. 4. Location of Machine Room- Top 5. Available Travel- 7.2 metres. ( Maximum) 6. Serving- Ground Floor to 2nd Floor (0,1,2) 3 Stops 3 Levels 3 Openings 7. Well Size- 1750 mm WideX 1550 mm Deep over the finished surface 8. Power supply- 415 Volts 3 phase, 50 cycles alternating current 10. Auxiliary Required- Single-phase 220 V 50 Cycles alternating current. 11. Car size (Clear Inside approx.---1300mm wideX1100 mm Deep. 12. Pit Depth--1600 mm 13. Head Room-4800 mm. 14. Car Enclosure- Painted Steel Car- swift 15. Flooring- PVC Flooring 16. Electric Light- Fluorescent Light Fittings 17. Fan- 300 mm Sweep one number. 18. No of Entrances- One Location - Front. 19. Car Entrance- Full Mid Bar Collapsible Gate (FMB 20. Landing Entrance- Full Mid Bar Collapsible Gate (FMB 21. Clear Opening- 800 mm Wide X 2000 mm High. 22. Indicators-Car & Landings-Direction & Position Indicator. Other Features --Emergency Alarm & Light. Call Registration LEDS . OSG Electronic Switch. Gate Open Warning Buzzer KONE Rescue Device.
R.C.C CULVERT : EARTHWORK IN EXCAVATION 1.1. Earthwork in excavation for foundations, trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, braking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lift as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Upto a depth of 2.00m below the existing ground level. (a) In ordinary soil
1.4: Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified. (b) Other than Guwahati city
PLAIN CEMENT WORKS 2.1.1.: Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls,brick work etc. as directed and specified including dewatering if necessary, and curing complete (shutering where necessary shall be measured and paid separately). (a) In prop 1:3:6 (1 cement : 3 coarse sand : 6 coarse agg. by volume (using mixture machine)
2.2.1: Providing and laying plain/reinforced cement concrete works with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work & reinforcement for reinforced cement concrete works (form work and reinforcement will be measured and paid separately) Using mixture machine (A) In sub structure upto plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit & the like and other works not less than 100mm thick upto plinth level. (b) M20 or Prop. 1 : 1.5 : 3
3.2.1.1: Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in 3.2.1.1: Columns, pillars, posts, struts of square/rectangular/polygon etc. and mass concrete works etc.
3.2.1.3: Formwork Flat surfaces such as soffits of suspended floors , roofs landing , cantilaever slabs chajjas , balconies and like For depth not exceeding1.00M
3.2.1.6: Vertical surface such as walls (any thickness), parapet walls, partitions, walls of septic tank, inspection pit and the like including attached pilasters, butresses, plinth and string courses and the like.
4.1.1.: Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the sub grade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
18.1.1: Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details,ying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). ISI approved super ductile TMT Bar (a) From primary producer : TATA / SAIL / Jindal steel / Shyam steel / RINL (i) TMT Corrosion resistant steel (CRS)
BOUNDARY WALL: 1.1 Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume (i) foundation of rcc column (ii) under tie beam
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and (iii) in coping over wall
3.1.1 Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.2.1.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (a) Using 38mm thick plank
3.1.1.1 Columns, Pillars, Posts & Strut
18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc. .
2.2.1 Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.
(B) In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.
4.1.4 Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (II) In superstructure above plinth level up to 1st floor level. (c) In proportion 1:5.(1 cement:5 sand)
6.2.3 20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick) a) In cement mortar 1:3
13.2.3 a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
GATE: 1.1 Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (b) In hard/ dense soil
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume
2.2.1 Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.
(B) In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.
3.1.1 Providing form work of 12mm thick ply wood board so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (a) Using 38mm thick plank
3.1.1 Providing form work of 12mm thick ply wood board so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (a) Using 38mm thick plank (ii) tie beam side
18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc. .
10.2 Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. II Ornamental grill (c) Fixed to Brickwork/P.C.C/R.C.C.
6.2.3 20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick) a) In cement mortar 1:3
13.2.3 a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
13.9.6 Finishing old/new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Dulux (ICI) paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
13.7.2 Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a). With ready mixed "red-lead/ red oxide" primer.
13.7.4 Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i).Surfaces over 100mm in width or girth. b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
DRAIN: 1.1 Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (a) Upto a depth of 2.0 m below existing GL (b) In hard/ dense soil
2.1.1(a) Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume
4.1.1 Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling
4.1.4(i) Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed in substructure upto plinth level (c) In proportion 1:5.(1 cement:5 sand)
5.1.10 Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15mm thick
PAVER BLOCK ROAD: 1.1 Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable materials to be used or auctioned upto lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm thickness. (ii)By Mechanical means
301 Excavation in Soil using Hydraulic Excavator CK 90 & Tippers with Disposal upto 1000metres.(Excavation for roadwork in soil with hydraulic excavltor of 0.9 cum bucket capacity including cutting & loading in tippers, trimming bottom & side slopes, in accordance with requirements of lines grades & cross sections, loading & disposal of cut road with in all lifts & leads upto 1000metres)
305 Construction of Subgrade and Earthen Shoulders (Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted tcmeet requirement of table (300-2) (a), including cost of testing of materials at site and laboratory as directed by the deptt.) (b) from private land
305 Construction of Embankment with Material Deposited from Roadway Cutting (Construction of embankment with approved materials deposited at site from roadway cutting & excavation fmm drain and foundition of other structures graded and compacted to meet requirement of table 300-2)
(C) Cost of haulage excluding loading and unloading for a distance of 64 kms on surfaced gravel road.
Granular Sub-base with Close Graded Material (Table:400-2) Construction of granular sub-base by providing coarse graded material, spreadingin uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at rotavator at OMC, and compacting with vibratory roller to achieve the desired denslty, complete as per cl 401(with an initial lead of 5 Km) (i) for grading - I Material
Cost of haulage excluding loading and unloading for a dlstance of 64 kmts on surfaced fravel road
404 Water Bound Macadam (Providing, laying, spreading and compacting stone aggregatesof specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller &10 tonnes in stages to proper grade and camber' applying and brooming requisite type of screening/ binding material to fill up the interstices of coarse aggregates, watering and compacting to the reqd. density ( with an initial lead of 5.0 km) A. By manual means (i) Grading I (a) Using Screening Crushable type such as Moorum or Gravel
Cost of haulage excluding loading and unloading for a dlstance of 64 kmts on surfaced fravel road
5.7.3.4 Providing and laying 80 mm thick factory made cement concrete paver block of M -30 grade factory made bY block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattem over and induding 50 mm thick compacted bed of course sand, filling the joints with coarsesand etc. all complete as per the direction of Engineer in Charge at all levels A (a) SUNROCK HIGH CTS TILES (Pavers) 80mm thick
Const. of Kerb Stone …complete as directed and specified.
RAISING OF LOW SITE AROUND BUILDING AREA: 1.4 Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified. (b) Other than Guwahati city
DISMANTLING AND DEMOLISHING (DISMANTLING WORKS): 23.2 Demolishing plain cement concrete including disposal of debris as directed for all levels (ii) Prop (1 : 3 : 6) or richer mix
23.3 Demolishing RCC work including stacking of steel bars and disposal of unserviceable material as directed for all levels
23.7 Demolishing brickwork including stacking of serviceable materials and disposal of unserviceable materials as directed for all levels
23.9 Dismantling wood work in frames, trusses, purlins and rafters including stacking the materials as directed by the department for all levels.
23.12 Dismantling all types of corrugated/ trapezoidal sheet roofing including ridges, hips, valleys and gutters etc. and stacking the materials as directed by the department for all levels
23.14 Demolishing the plastering from walls/ R.C.C. and P.C.C. members without causing any damage to the wall/ member upto any height including disposal of debris as directed for all levels.
23.18 (d) Dismantling and removing the existing door and window frame (chowkath) both wooden and steel of different sizes without damaging the walls and removing the frame and necessary repairs to the edges of the walls as directed for all levels. (i) Area of door/window up to 3.00 m2
23.2 Dismantling all types of ceiling, partition and wall lining and stacking the materials as directed by the department for all levels
FOR NORMAL PREPARATION OF SITE MISCELLANEOUS WORKS Jungle clearence including uprooting of vegitation, grass, brush-wood, sapling and trees not exceeding 300mm girth and disposal of the same outside the periphery and lift upto 1500mm
25.4 (a) Felling and removing (c).Cutting trees including uprooting and removing where necessary. (iii).1500 mm to 1800mm girth.
25.5 Surface dressing of ground including removing vegitation and/ or undulation of ground not exceeding 150mm deep and disposal of rubbish outside the periphery and lift up to 1800mm in all kinds of soil.
25.7 Cutting down trees where the building is to beconstructed of girth exceeding 300mm, grubb ing up roots, filling pits and levelling off ground lopping branches, trimming and removeing to distance beyond 30m and stacking serviceable materials and cleaning site etc. as directed. (ii). Girth exceeding 1000mm but not exceeding 1500mm
MRINAL DAS
Manas Das
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .