| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹34.5 L+₹7.0 L (25.6%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L2 | Rejected-Finance Being L2 |
Tender Value
₹39.2 L
EMD Value
₹78,477
Closing Date
13 Sept 2022, 6:00 pmClosed
AGM(E-E)
O/o. Jt. GM(E-E)/AAI/Begumpet Airport, Hyderabad
Replacement of Old CCRs for GLF System at Begumpet Airport, Hyderabad
2022_AAI_125241_1
AAI/HYD/ENGG(E)/CCR/NIT-02/22
Open Tender
Electrical Works
Item Rate
90 days
works
Please refer Tender documents.
15 documents required · 15 mandatory
₹1,180
₹78,477
12 Dec 2022
23 Aug 2022
15 Sept 2022
24 Aug 2022
13 Sept 2022
24 Aug 2022
24 Aug 2022 - 7 Sept 2022
Amount
SITC of indoor type microprocessor based, air-cooled constant current regulator of thyristor control electronic type suitable for use on 240/415 Volt AC supply, 50 Hz, in put AC supply with with below mentioned output power at 6.6 Amps with 5 Steps variation of current output suitable for local and remote control operation with24/ 48 Volt DC control supply complete with output current indicated on multifunction digital dispaly, over current, over voltage, earth fault protection and earth leakage meter, positive back indication equipments relay contactor etc, as required as per specification of following rating. a) 4 KW MPCCR at 6.6 Amp, supply voltage 240 VAC.
SITC of indoor type microprocessor based, air-cooled constant current regulator of thyristor control electronic type suitable for use on 240/415 Volt AC supply, 50 Hz, in put AC supply with with below mentioned output power at 6.6 Amps with 5 Steps variation of current output suitable for local and remote control operation with 24/48 Volt DC control supply complete with output current indicated on multifunction digital dispaly, over current, over voltage, earth fault protection and earth leakage meter, positive back indication equipments relay contactor etc, as required as per specification of following rating. a) 7.5 KW MPCCR at 6.6 Amp, supply voltage 240 VAC tapping at 4KW.
SITC of indoor type microprocessor based, air-cooled constant current regulator of thyristor control electronic type suitable for use on 240/415 Volt AC supply, 50 Hz, in put AC supply with with below mentioned output power at 6.6 Amps with 5 Steps variation of current output suitable for local and remote control operation with 24/48 Volt DC control supply complete with output current indicated on multifunction digital dispaly, over current, over voltage, earth fault protection and earth leakage meter, positive back indication equipments relay contactor etc, as required as per specification of following rating. a) 30 KW MPCCR at 20 Amp, supply voltage 415 VAC tapping at 20KW.
SITC of indoor type microprocessor based, air-cooled constant current regulator of thyristor control electronic type suitable for use on 240/415 Volt AC supply, 50 Hz, in put AC supply with with below mentioned output power at 6.6 Amps with 5 Steps variation of current output suitable for local and remote control operation with 24/48 Volt DC control supply complete with output current indicated on multifunction digital dispaly, over current, over voltage, earth fault protection and earth leakage meter, positive back indication equipments relay contactor etc, as required as per specification of following rating. a) 50 KW MPCCR at 20 Amp, supply voltage 415 VAC tapping at 30KW.
Manish Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .