Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-Finance | L1 | Accepted-Finance L1 Contractor | |
| 2 | L2₹18.9 L+₹3.2 L (20.5%)Rejected-Finance KARUKAPPILLY THATTATHUKUDIYIL BUILDING KOLENCHERY 682311 | KOLENCHERY | ERNAKULAM | KERALA | 682311 | L2 | Rejected-Finance Not L1 Contractor | |
| 3 | L3₹19.2 L+₹3.5 L (22.3%)Rejected-Finance | L3 | Rejected-Finance Not L1 Contractor |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
1 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Director
NIT Calicut, NIT Calicut Campus PO, Kerala, 673601
Electrification of MED Faculty Rooms in the Old Central Library Building
2024_NITC_799477_1
Engg/EMU/JE3/0002/MED-Old Library
Open Tender
Electrical Works
Item Rate
45 days
NIT Calicut, NIT Calicut Campus PO, 673601
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹38,000
Yes
27 May 2024
7 Mar 2024
3 Apr 2024
7 Mar 2024
1 Apr 2024
7 Mar 2024
Amount
Wiring for light point/ fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring of twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required
Supplying and fixing of 20 mm (medium class) ivory coloured rigid PVC conduit along with accessories in surface / recess including cutting the wall / floor and making good the same in case of recessed conduit as required.
Supplying and fixing of 25 mm (medium class) ivory coloured rigid PVC conduit along with accessories in surface / recess including cutting the wall / floor and making good the same in case of recessed conduit as required.
Supplying and fixing of 32 mm (medium class) ivory coloured rigid PVC conduit along with accessories in surface / recess including cutting the wall / floor and making good the same in case of recessed conduit as required.
Supplying and drawing 3 numbers 1.5 sq.mm FRLS PVC insulated copper conductor single core cable (Red, Black & Green) in the existing surface/recessed PVC conduit as required.
Supplying and drawing 3 numbers 2.5 sq.mm FRLS PVC insulated copper conductor single core cable (Red, Black & Green) in the existing surface/recessed PVC conduit as required.
Wiring for circuit/ submain with 4 X 6 sq. mm + 2 X 6 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
Wiring for circuit/ submain with 2 X 4 sq. mm + 1 X 4 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
Wiring for circuit/ submain with 2 X 6 sq. mm + 1 X 6 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
Wiring for circuit/ submain with 2 X 10 sq. mm + 1 X 6 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
Wiring for circuit/ submain with 4 X 10 sq. mm + 2 X 6 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Wiring for circuit/submain wiring along with earth wire with 4 x 16 sq.mm + 2 x 6 sq.mm of FRLS PVC insulated copper conductor, single core cable with surface/ recessed suitable size medium class PVC conduit etc. as required.
Supplying and fixing 5/6A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required in the existing DLP trunking.
Supplying and fixing 3 pin 5/6 A modular socket outlet on the existing modular plate & switch box including connection, but excluding modular plate etc as required in the existing DLP trunking.
Supplying and fixing 15/16A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required in the existing DLP trunking.
Supplying and fixing 6 pin 15/16 A modular socket outlet on the existing modular plate & switch box including connection, but excluding modular plate etc as required in the existing DLP trunking.
Supplying and fixing 2 Module, GI box alongwith modular base & modular switches in surface/recess etc.as required.
Supplying and fixing 3 pin 5/6 A socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing of DLP Plastic trunking of size 150 x 50 mm with clip on partitions (2 compartments) 2 Nos 65 mm or nearest suitable width flexible cover, fitted on the wall with steel screws, cup washers etc. as required.
Supplying and fixing of 3 module frame and cover plate for 65 mm or nearest size cover on DLP trunking etc. as required.
Supplying and fixing of 4 module frame and cover plate for 65 mm or nearest size cover on DLP trunking etc. as required.
Supplying and fixing of 6 module frame and cover plate for 65 mm or nearest size cover on DLP trunking etc. as required.
Supplying and fixing of flat angles in the existing DLP Plastic trunking of size 150 x 50 mm as required
Supplying and fixing of end cap in the existing DLP Plastic trunking of size 150 x 50 mm as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch connections etc. as required.
Supply of 28W 1200 mm sweep 5 Star rated BLDC ceiling fan with input voltage range (140-285V), 280 rpm, Air delivery 272 m3/min, regulator supported type, Aluminium Blade material ,white colour,with 3 years onsite warranty, conforming to IS:374:2019
Supply of 28W 1200 mm sweep 5 Star rated BLDC ceiling fan with input voltage range (140-285V), 280 rpm, Air delivery 272 m3/min, regulator supported type, Aluminium Blade material ,white colour,with 3 years onsite warranty, conforming to IS:374:2019
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 4 Module, GI box along with modular base & modular switches in surface/recess etc.as required.
Supplying and fixing 6 Module, GI box along with modular base & modular switches in surface/recess etc.as required.
Supplying and fixing extra down rod of 10 cm length G.I. pipe,15mm dia, heavy gauge including giving connection with 0.5 sq.mm 3 core round flexible copper wire and painting the down rod etc. as required. (Note:More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Supply and fixing 300 mm sweep exhaust fan with front guard working on 240 Volts AC supply, after cutting holes on wall, making good the damages, giving connections using 1.5 sq.mm 3 core round flexible copper wire, etc as required.
Supply and fixing 300 mm sweep exhaust fan with front guard working on 240 Volts AC supply, on existing exhaust fan provision, making good the damages, giving connections using 1.5 sq.mm 3 core round flexible copper wire, etc as required
Supplying and fixing of 450 mm sweep wall fan, with three speed positions,Aluminium blade and pulling cord,1350 RPM, 100 CMM air delivery (SStorm2 or compatible) giving connection as required.
Supply and fixing of box type tube fittings (Batten & T8 LED Tube), complete with side holders and 18/20 watt 4 feet T8 LED tube, Including suitable GI clamp for fixing at an angle of 45 degree. etc, as required.(T8 LED-Bajaj BLRB 18W CW LED, Batten- Bajaj BLRB-DB 118 I, or compatible).
Supply and fixing of box type tube fittings (Batten & T8 LED Tube), complete with side holders and 18/20 watt 4 feet T8 LED tube,.including conections etc, as required.(T8 LED-Bajaj BLRB 18W CW LED, Batten- Bajaj BLRB-DB 118 I, or compatible).
Supply and fixing of box type tube fittings (Batten & T8 LED Tube), complete with side holders and 2 X 18/20 watt 4 feet T8 LED tube, including conections etc, as required.(T8 LED-Bajaj BLRB 18W CW LED, Batten- Bajaj BLRB-DB 218, or compatible).
Supply and fixing of 10 watt,2 feet LED batten, Efficacy >100 lm/watt, cool white LED luminaire, inculding connections etc as required.(Crompton CCS-103-10-65-SL-DP-NWH or compatible)
Supply and fixing of surface mounting type (square type), 2x2 or nearest size of 24 W, 5700K, CRI >80, Efficacy >100 lm/watt, THD <10% cool white LED luminaire with white flat light opal diffuser, Robust PDC aluminum housing with LEDs complete with all accessories etc, as required. (Crompton -LCTLSNE-24-FO-CDL(2X2) or compatible) *** Bidder should submit OEM warranty certificate minimum 02 year or above along with supply of product at site.
Supply and fixing of surface mounting type (square type) Light of 6 W, 6500K, CRI >80, Efficacy >100 lm/watt, cool white LED luminaire with white flat light opal diffuser, Robust PDC aluminum housing with LEDs complete with all accessories etc, as required.(Crompton -LCDSPLN-S-06-CDL or compatible) *** Bidder should submit OEM warranty certificate minimum 02 year or above along with supply of product at site.
Supply and fixing of recess mounting type (square type),1x1or nearest size of 18 W, 1500 lm, 5700K, CRI >80, Efficacy >100 lm/watt, THD <10% cool white LED luminaire with white flat light opal diffuser, Robust PDC aluminum housing with LEDs complete with all accessories etc, as required. (Crompton -LCTLRNE-18-CDL(1X1)or compatible) *** Bidder should submit OEM warranty certificate minimum 02 year or above along with supply of product at site.
Supply and fixing of surface mounting type (square type),1x1or nearest size of 18 W, 1500 lm, 5700K, CRI >80, Efficacy >100 lm/watt, THD <10% cool white LED luminaire with white flat light opal diffuser, Robust PDC aluminum housing with LEDs complete with all accessories etc, as required. . (Crompton -LCTLSNE-18-FO-CDL(1X1)or compatible) *** Bidder should submit OEM warranty certificate minimum 02 year or above along with supply of product at site.
Supplying and fixing 6 - 32 amps rating, 240 Volts, 'C' curve miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connectons, testing and commissioning etc as required.
Supplying and fixing 32 amps rating, 415 Volts, 'C' curve miniature circuit breaker suitable for inductive load of Triple pole in the existing MCB DB complete with connectons, testing and commissioning etc as required.
Supplying and fixing 32 amps rating, 415 Volts, 'C' curve miniature circuit breaker suitable for inductive load of four pole in the existing MCB DB complete with connectons, testing and commissioning etc as required.
Supplying and fixing 25 amps rating, 240 Volts, 'C' curve miniature circuit breaker suitable for inductive load of Double pole in the existing MCB DB complete with connectons, testing and commissioning etc as required.
Supplying and fixing 32 amps rating, 240 Volts, 'C' curve miniature circuit breaker suitable for inductive load of Double pole in the existing MCB DB complete with connectons, testing and commissioning etc as required.
Supplying and fixing 40 amps rating, Four pole (Three phase and neutral) 415 Volts, residual current circuit breaker (RCCB), having a sensitivity current up to 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required.
Supplying and fixing 25 amps rating, Double pole (single phase and neutral) 240 Volts, residual current circuit breaker (RCCB), having a sensitivity current up to 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required.
Supplying and fixing 40 amps rating, Double pole (single phase and neutral) 240 Volts, residual current circuit breaker (RCCB), having a sensitivity current up to 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required.
Supplying and fixing 63 amps rating, Four pole (Three phase and neutral) 415 Volts, residual current circuit breaker (RCCB), having a sensitivity current up to 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required.
Supplying and fixing 63 amps rating, four pole, 415 Volts, 'C' curve miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connectons, testing and commissioning etc as required.
Supplying and fixing 63 amps rating, Triple pole, 415 Volts, 'C' curve miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connectons, testing and commissioning etc as required.
Supplying and fixing 3 phase 6 way , double door, suface/recess mounting, vertical type, 415 V, TPN distribution board with provision for fixing MCCB as incomer and TP MCB as out going, complete with 200 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB etc)
Supplying and fixing 3 phase 4 way (8 + 12), Double door, Vertical type, three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 3 phase 4 way (8 + 12), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 16 way, single pole and neutral Double door, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 12 way, single pole and neutral Double door, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 4 way, single pole and neutral Double door, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 160 A 16 kA DPX3 160 FP MCCB (Thermal magnetic : O/L & S/C protection ) in the existing MCCB DB, complete with connections, testing and commissioning etc. as required.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supply of 1.1 kV grade 3.5C x 70 sq.mm, Aluminium conductor XLPE insulated PVC sheathed armoured power cable (as per IS) as required.
Laying and fixing of one number 1.1 kV grade Aluminium conductor XLPE insulated PVC sheathed armoured power cable of 3.5C x 70 sq.mm size, clamping on wall using suitable metal clamps spacing not exceed 50 cm etc. as required.
Supply and making end termination with brass compression gland and aluminium legs for 3.5C x 70 sq.mm (35 mm) size of XLPE insulated PVC sheathed armoured aluminium cable as required.
Supply of 1.1 kV grade 4 C x 25 sq.mm, Aluminium conductor XLPE insulated PVC sheathed armoured power cable (as per IS) as required.
Laying and fixing of one number 1.1 kV grade Aluminium conductor XLPE insulated PVC sheathed armoured power cable of 4 C x 25 sq.mm size, clamping on wall using suitable metal clamps spacing not exceed 50 cm etc. as required.
Supply and making end termination with brass compression gland and aluminium legs for 4 C x 25 sq.mm (28 mm) size of XLPE insulated PVC sheathed armoured aluminium cable as required.
Supply and laying one number of the 8 SWG good quality bare copper wire along the cable with connections etc. as required.
Power Care Electrical
AJESH KK
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .