Loading…
Loading…
Tender Value
Refer Docs
Closing Date
2 Jun 2026, 3:00 pmClosed
O/o THE EE/MED
Office of the Executive Engineer Metropolitan Electrical Division Block-DF, Sector-I, 4th Floor, Jalasampad Bhawan, Salt Lake City, Kolkata -700091
SITC of Automatic real time based Water level sensor monitoring system along with cloud based data storage and visualization through mobile application... at Jalasampad Bhawan, Salt Lake City, Kol - 700091.
2026_IWD_1024306_1
WBIW/EE/MED/EOI-01/2026-27
Open Tender
ELECTRICAL WORKS ORG
EOI
JALASAMPAD BHAWAN
Please refer Tender documents.
4 documents required · 4 mandatory
Exempted
O/o THE EE/MED
2 Jun 2026
18 May 2026
2 Jun 2026
18 May 2026
2 Jun 2026
18 May 2026
22 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, delivery, installation and commissioning of Smart RTU Controller:
The RTU Panel consist of following:
The cyber Secured RTU having Dual ARM® Cortex® A7, plus ARM Cortex M3; 500 Mhz CPU Controller with 2x Ethernet port, 4x Serial ports and 4x DI, 2x DO, 4x Cntr In, 4 AI IOs.
The RTU should have DNP3 level 4 with Secure Authentication and IEC 60870-5-104 communication protocols, IEC61131 logic programming languge and G3 Conformal coatated IP20 module.
The RTU panel should have inbuilt Real Time Clock & Calendar provide accurate time stamp for event log and data log purpose. The DNP3 protocol of RTU Panel should monitor the BAD Network and log the Data in a local SD Card. The DNP3 protocol of RTU Panel update the missing Data along with current Data when the Network becomes Healthy. The Modbus TCP over DNP3 protocol Data transmitted through IP Sec VPN Tunnel with Data Encryption for highest Data Security.
The PLC CPU should have inbuilt Firewall which should be Achillies Level 2 Certified.
The RTU panel shoud be integrated with 5G Dual SIM GPRS Gateway and Modbus to JSON Data Gatway for Cloud Server Data connectivity.
The RTU module should be assembled in a SS Enclosure Panel of size 400mm x 300mm x 210mm (HxWxD) with protection class IP66.
The RTU should operate from 230V AC 50Hz, +/- 10% Raw power source through 24V 4.5A DC SMPS.
The isolated Sernsor Power supply should be available from RTU Panel with voltage surge free and over voltage protection.
The normal working temperature of the Panel should be 50 deg. C and max. temperature withstand up to 70 Deg C.
The RTU should operate in 95% RH without any degradation of performance.
Make: Si of Schneider-Electric | - | Job | - | - |
| 2 | Level Sensors Radar level sensor having LED + Bluetooth 2-wire 4-20mA Thread ASME MNPT1-1/2, PVDF
IP68, Range: 0-8m, Temp: -40 to 60 Deg C, Pressure: -1 to 3 Bar,
Accuracy: +/- 5mm, Aux Supply Voltage: 24V DC Loop Powered
Make: Endress+Hauser India Pvt. Ltd. | - | Nos | - | - |
| 3 | 32" FHD Touch LED All in one PC with Internet Connection | - | No | - | - |
stage.html
html • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.84 MB
BOQ_2517334.xls
BOQ • 0.34 MB
2911.pdf
Tender Documents • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .