Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST BIDDER | |
| 2 | L2₹16.2 L+₹98,988.18 (6.50%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹17.1 L+₹1.9 L (12.4%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 4 | L4₹18.2 L+₹2.9 L (19.4%)Rejected-Finance D NO 39 33 88 2 PLOT NO MIG 208 MADHAVADHARA VUDA COLONY VISAKHAPATNAM 530018 | VISAKHAPATANAM | ANDHRA PRADESH | 530018 | L4 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 5 | L5₹18.3 L+₹3.1 L (20.2%)Rejected-Finance D NO 65 6 500 2 MULAGADA COLONY HIMACHALNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L5 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| Sl No | Description | Qty | Unit | ANJANA ENTERPRISES L1 | SRI DHANESWARI ENGINEERING WORKS L2 | SATYAM ENGINEERS L7 | JAHNAVI ASSOCIATES L3 | SRI LAKSHMI GANAPATHI CONSTRUCTIONS L8 | HARSHA CONSTRUCTIONS AND ENGINEERING WORKS L6 | ANAND ENTERPRISES AND ENGINEERS L5 | RAVI VARMA JAMPANA L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Lifting of cover from manhole / Gully trap and taking out waste soil, sludge and other foreign materials from gully trap / manhole etc, volume not exc 1.5 cum each, removal of sludges in water sealed container to a distance not exc 50 m and washing manhole / gully trap with adequate quantity of water and refixing the cover in the same location complete all as specified and directed. | 240 | Each | 199 ₹47,760 | 250 ₹60,000 | 275 ₹66,000 | 260 ₹62,400 | 155 ₹37,200 Lowest | 260 ₹62,400 | 270 ₹64,800 | 250 ₹60,000 |
| 2.00 | Cleaning by rodding/ bamboo split and taking out waste soil sludge and other foreign materials from sewage line any dia removed in sealed container (from WC to onward upto septic tank/soak well) and flushing with water etc complete all as specified and directed. | 680 | Rm | 25 ₹17,000 Lowest | 30 ₹20,400 | 35 ₹23,800 | 32 ₹21,760 | 45 ₹30,600 | 55 ₹37,400 | 35 ₹23,800 | 50 ₹34,000 |
| 3.00 | M&L for pumping out sludge water from manhole of any section for cleaning blocked sewage line, depth of manhole exc 1.20 mtr but not exc 1.80 mtr complete all as specified and directed. | 80 | Each | 190 ₹15,200 Lowest | 220 ₹17,600 | 222 ₹17,760 | 212 ₹16,960 | 250 ₹20,000 | 300 ₹24,000 | 215 ₹17,200 | 300 ₹24,000 |
| 4.00 | Cleaning of existing open or covered drain of any section and depth by removing mud, sludge or foreign materials from existing storm water drain/covered drain, static tanks etc, flushing with adequate quantity of water and removing the sludge to a distance not exc 50 m complete all as specified and directed. | 600 | Rm | 80 ₹48,000 | 100 ₹60,000 | 102 ₹61,200 | 92 ₹55,200 | 250 ₹1,50,000 | 200 ₹1,20,000 | 95 ₹57,000 | 50 ₹30,000 Lowest |
| 5.00 | Cleaning of blocked WC by using vaccum pump including opening and refixing/CI cover to bend and branch pieces and finally cleaned with adequate quantity of water complete all as specified and directed. | 120 | Each | 140 ₹16,800 Lowest | 150 ₹18,000 | 160 ₹19,200 | 152 ₹18,240 | 450 ₹54,000 | 240 ₹28,800 | 158 ₹18,960 | 200 ₹24,000 |
| 6.00 | Demolition and breaking up drain pipes of 150mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar and taking out of trenches if required complete all as specified. | 275 | Rm | 30 ₹8,250 Lowest | 50 ₹13,750 | 42 ₹11,550 | 32 ₹8,800 | 150 ₹41,250 | 60 ₹16,500 | 35 ₹9,625 | 50 ₹13,750 |
| 7.00 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan area in hard / dense soil and getting out complete all as specified and directed. | 90 | Cum | 290 ₹26,100 | 298 ₹26,820 | 350 ₹31,500 | 330 ₹29,700 | 520 ₹46,800 | 250 ₹22,500 Lowest | 340 ₹30,600 | 300 ₹27,000 |
| 8.00 | Returning, filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified & directed. | 78.09 | Cum | 177 ₹13,821.93 | 170 ₹13,275.3 | 185 ₹14,446.65 | 186 ₹14,524.74 | 200 ₹15,618 | 150 ₹11,713.5 Lowest | 195 ₹15,227.55 | 200 ₹15,618 |
| 9.00 | Removing excavated material to a distance n exc 50 mtr and depositing where directed at a level n exc 1.50 mtr above the starting point complete all as specified & directed. | 11.91 | Cum | 159 ₹1,893.69 | 150 ₹1,786.5 Lowest | 180 ₹2,143.8 | 165 ₹1,965.15 | 420 ₹5,002.2 | 220 ₹2,620.2 | 175 ₹2,084.25 | 250 ₹2,977.5 |
| 10.00 | Supply, laying and jointing 150 mm nominal bore dia DWC(HDPE double wall corrugated), socketed and sewage pipes having 6.0 M length, conforming to IS 16098 (Part-2) of SN-4 Stiffiness with and including necessary jointing matrials etc complete all as specified and directed. | 150 | Rm | 459 ₹68,850 | 450 ₹67,500 Lowest | 513 ₹76,950 | 500 ₹75,000 | 1,250 ₹1,87,500 | 850 ₹1,27,500 | 520 ₹78,000 | 900 ₹1,35,000 |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
28 Jun 2025, 6:00 pmClosed
GE(I)(CG) VIZAG
GE (I) (CG) VIZAG Military Engineer Services, CGWO Building, C/o Fleet Mail Office, Visakhapatnam - 530 014
REPAIR AND REPLACEMENT OF SEWAGE LINE, CLEANING OF SEWAGE LINE, MANHOLES , SEPTIC TANK AND OTHER CONNECTED WORKS FOR MD ACCN AT ICGS VISAKHAPATNAM UNDER GE(I)(CG)VIZAG
2025_MES_713157_1
GE(I)CG/VIZ/TOKEN 22 OF 2025-26
Open Tender
Miscellaneous Works
Item Rate
270 days
Visakhapatnam
DETAIL AS PET NIT OF THE TENDER
9 documents required · 9 mandatory
₹500
GE(I) CG VIZAG
₹36,000
Yes
26 Aug 2025
9 Jun 2025
30 Jun 2025
9 Jun 2025
28 Jun 2025
22 Jun 2025
Amount
Lifting of cover from manhole / Gully trap and taking out waste soil, sludge and other foreign materials from gully trap / manhole etc, volume not exc 1.5 cum each, removal of sludges in water sealed container to a distance not exc 50 m and washing manhole / gully trap with adequate quantity of water and refixing the cover in the same location complete all as specified and directed.
Cleaning by rodding/ bamboo split and taking out waste soil sludge and other foreign materials from sewage line any dia removed in sealed container (from WC to onward upto septic tank/soak well) and flushing with water etc complete all as specified and directed.
M&L for pumping out sludge water from manhole of any section for cleaning blocked sewage line, depth of manhole exc 1.20 mtr but not exc 1.80 mtr complete all as specified and directed.
Cleaning of existing open or covered drain of any section and depth by removing mud, sludge or foreign materials from existing storm water drain/covered drain, static tanks etc, flushing with adequate quantity of water and removing the sludge to a distance not exc 50 m complete all as specified and directed.
Cleaning of blocked WC by using vaccum pump including opening and refixing/CI cover to bend and branch pieces and finally cleaned with adequate quantity of water complete all as specified and directed.
Demolition and breaking up drain pipes of 150mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar and taking out of trenches if required complete all as specified.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan area in hard / dense soil and getting out complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified & directed.
Removing excavated material to a distance n exc 50 mtr and depositing where directed at a level n exc 1.50 mtr above the starting point complete all as specified & directed.
Supply, laying and jointing 150 mm nominal bore dia DWC(HDPE double wall corrugated), socketed and sewage pipes having 6.0 M length, conforming to IS 16098 (Part-2) of SN-4 Stiffiness with and including necessary jointing matrials etc complete all as specified and directed.
Demolition reinforced cement concrete in slab, beams, staircase, landings, chajjas and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
S&F TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L for Precast Reinforced Cement Concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in cover slab (For manhole etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in cement mortar 1:6 including necessary form, moulds, etc complete all as specified and directed . (Note : Reinforcement shall be measured and paid separately)
Complete removing the plants from the surfaces of the building with complete roots, applying recommended chemical to prevent further growth as directed, making good the disturbed surface with cement mortar 1:3 and applying the same surface finish of the existing surface and finished to match with the surrounding surfaces including removal of debris etc., out side the premises complete all as required complete all as specified and as directed.
Cleaning of CI/PVC SWR pipe of any dia by rodding or with bamboo split including removing and refixing inspection eye door cover in existing position etc complete all as specified and directed.
Dismantling of CI/PVC SWR pipes of 100 bore including fittings jointed in cement mortar from wall/floor/trenches etc and removal of unserviceable pipes complete all as specified and directed.
S&F 100 mm bore cast iron rain (Sand Cast) water pipes fixed to walls in any length with or without ears jointed with cement sand mortar 1:1 complete all as specified and directed.
S&F cast iron bends of bore 100 mm dia with oval access door as in soil/waste pipe including taking down Old unserviceable one complete all as specified and directed..
Taking down eaves gutters and rainwater/soil/waste pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed
S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed.
Fixing only 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed. (Note: Pipe retrive from taking down of rain water pipe here-in-before shall be re-used.)
S & F 75 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed.
S & F in repair 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
S & F in repair 75 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
S & F in repair 110 mm bore, PVC (SWR) vent cowl of any radius complete all as specified and directed.
Disconnecting existing PVC/RCC tanks of capacity not exc 250 Ltrs., setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Note: Cleaning, repairing, etc. shall be measured and paid separately.)
Disconnecting existing PVC/RCC tanks of capacity exc 250 Ltrs but not exc 500 Ltrs., setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Note: Cleaning, repairing, etc. shall be measured and paid separately.)
Disconnecting existing PVC/RCC tanks of capacity exc 500 Ltrs but not exc 1000 Ltrs., setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Note: Cleaning, repairing, etc. shall be measured and paid separately.)
Cleaning and removing all scale and dirt, etc, from PVC/RCC tanks of capacity not exc 250 Ltrs., and from mouths of circulating pipes, etc complete all as specified and directed.
Cleaning and removing all scale and dirt, etc, from PVC/RCC tanks of capacity exc 250 Ltrs but not exc 500 Ltrs, and from mouths of circulating pipes, etc complete all as specified and directed.
Cleaning and removing all scale and dirt, etc, from PVC/RCC tanks of capacity exc 500 Ltrs but not exc 1000 Ltrs, and from mouths of circulating pipes, etc complete all as specified and directed.
Cleaning and removing all scale and dirt, etc, from PVC/RCC tanks of capacity exc 1000 Ltrs but not exc 2000 Ltrs, and from mouths of circulating pipes, etc complete all as specified and directed.
S & F 250 litres capacity rotational moulded polyethylene water storage tanks, double layer construction, ISI marked (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed.
S & F 500 litres capacity rotational moulded polyethylene water storage tanks , double layer construction, ISI marked (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed.
S & F 1000 litres capacity rotational moulded polyethylene water storage tanks , double layer construction, ISI marked (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed.
S&F in repairs 25 mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F in repairs 20 mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F in repairs 15 mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F in repairs gun-metal, globe or gate valves of 25mm bore dia, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repairs gun-metal, globe or gate valves of 20mm bore dia, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repairs gun-metal, globe or gate valves of 15mm bore dia, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repairs sinks with drainage board made of stainless steel l mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repairs sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repair vitreous China wash hand basin, white, flat back, size 630 x 450 mm excluding taps, waste, chain and plug and porcelain stopper but including brackets, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and directed.
S & F in repairs, vitreous China squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rest and 'P' or 'S' trap, including provision of lime concrete bedding, connection to trap and flushing pipe etc complete including making good to disturbed surfaces of floor to match with existing specifications complete all as specified and directed.
S & F in repairs, 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and directed.
S & F in repairs, vitreous China wash down water closet pan (pedestal pattern), white, including connection to outgoing drain and flushing pipe, anti syphonic pipe with seat and cover complete but excluding flushing cistern & flush pipe including making good damaged/disturbed surfaces complete all as specified and directed.
S&F in repairs vitreous china urinals, half stall, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed.
S&F in repair 15mm bore bib tap chorime plate fancy type alloy with crutch or butterfly handels screwed down for iron pipes or for brass ferrule complete all as specified and directed .
S&F in repair 15mm bore stop valves chorime plate alloy screwed down high pressure with crutch or butter fly handles screwed both ends for iron pipe or for union complete all as specified and directed .
S&F in repair, 15 mm dia of bore, fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe & fixed complete all as specified and directed.
S&F in repairs vitreous china urinal partition white of size 310x700 mm with slabs terminating about 40 cm above floor line complete all as specified and directed.
S&F in repairs 32 mm waste fittings, brass chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. .
S & F in repairs 15mm bore, PVC connection pipe 450mm long with PTMT nuts at both ends complete all as specified and directed.
S&F in repair, Health Faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube & ABS wall hook including making connections & fixed in position complete in all respect as specified.
S&F in repair, 125 mm size, Brass chromium plated shower rose with or without swivel joints, including fixing to steel pipe or union complete all as specified and directed.
S&F in repair, Sheet Glass Shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed.
S&F in repair toilet paper holder with flat recessed type stainless steel. Complete all as specified & directed.
S&F in repair 32 mm dia flexible PVC waste pipe for basin, sink & urinal etc complete all as specified and directed.
S&F in repairs grating round 140 mm size of PTMT (Minimum weight 50gms) complete all as specified and directed.
S&F in repairs of 100mm Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
Taking down steel tubing and connections incl cleaning for refixing or removal form site for 15mm bore pipe complete all as specified and directed.
Taking down steel tubing and connections incl cleaning for refixing or removal form site for 20mm bore pipe complete all as specified and directed.
S&F 15mm bore tubes medium grade galvanized with all fitting and fixed complete to walls and ceilings or laid in floors of any length complete all as specified and directed.
S&F 20mm bore tubes medium grade galvanized with all fitting and fixed complete to walls and ceilings or laid in floors of any length complete all as specified and directed.
Refixing 15mm bore tubes medium grade galvanized with all fitting and fixed complete to walls and ceilings or laid in floors of any length complete all as specified and directed. (Note: Pipe retrive from taking down item shall be re-used.)
Refixing 20mm bore tubes medium grade galvanized with all fitting and fixed complete to walls and ceilings or laid in floors of any length complete all as specified and directed. (Note: Pipe retrive from taking down item shall be re-used.)
Dismantling of floor, hearth or wall tiles / terrazo including cement mortar bedding (but not backing), removal servicable tiles to store and rubbish off the premises complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
Material and labour for Glazed ceramic tiles of size 350x 250x 7mm/ 450X 350X 7mm thick in vertical surfaces such as dado/ skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 complete all as specified and directed.
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish off the premises complete all as specified and directed.
M & L for Brick work with fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 using old size brick complete all as specified and directed.
M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description in ground floors and paving's not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for plain cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) as in surface channels and drains complete all as specified and directed.
Claning of septic tank/soak pit 50 to100 users capacity and filter bed of any depth by removing of sludge, silt, sand or material of any description by dewatering of septic tanks and filter beds including blocking/diversion of inlet line by means of mechanical process for the period and removing the material obtained to outside MD land including cleaning of surface completely with water complete in foul position (Solid material will be measured and dewatering is included in rate) complete all as specified and directed.
SRI DHANESWARI ENGINEERING WORKS (BID ID -3338625)
JAHNAVI ASSOCIATES (BID ID -3340085)
RAVI VARMA JAMPANA (BID ID -3339376)
ANAND ENTERPRISES AND ENGINEERS (BID ID -3339763)
HARSHA CONSTRUCTIONS AND ENGINEERING WORKS (BID ID -3339551)
SATYAM ENGINEERS (BID ID -3339335)
SRI LAKSHMI GANAPATHI CONSTRUCTIONS (BID ID -3339882)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .