Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 CrAccepted-AOC 121 MODEL TOWN AMBALA CITY HARYANA 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | ₹7.7 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹8.0 Cr+₹31.0 L (4.05%)Rejected-AOC | ₹8.0 Cr+₹31.0 L (4.05%) | L2 | Rejected-AOC Other than Lowest Bidder |
| 3 | L3₹8.2 Cr+₹58.6 L (7.65%)Rejected-AOC 583 URBAN ESTATE II HISAR 125005 | HISAR | HISAR | HARYANA | 125005 | ₹8.2 Cr+₹58.6 L (7.65%) | L3 | Rejected-AOC Other than Lowest Bidder |
| 4 | Rejected-Technical 6313 14 PUNJABI MOHALLA AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | - | - | Rejected-Technical Enlistment valid upto 31 Dec 2025 |
| Sl No | Description | Qty | Unit | Siya constructions L3 | J.D.Builders L1 | Adhunik Builders L2 |
|---|---|---|---|---|---|---|
| 1.00B/R Work | ||||||
| 2.00 | Cutting holes exceeding 400 Sq cm but not exceeding 0.10 Sq m, into or through brick walls built in cement mortar and making good in cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate and removal of debris complete all as specified and directed. | 490 | Per centimeter of depth (of cutting) | 8 ₹3,920 | 5 ₹2,450 Lowest | 150 ₹73,500 |
| 3.00 | Cutting openings through brick walls built in cement mortar for door, window and other openings or enlarging existing openings, converting window into door openings etc. or cutting out defective brick work for under- pinning including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc. to store and removal of rubbish/debris complete all as specified and directed. | 3 | Cubic Metre | 400 ₹1,200 | 300 ₹900 Lowest | 1,500 ₹4,500 |
| 4.00 | Forming jambs, etc to openings, including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work; new work built in cement mortar 1:6 and removal of debris complete all as specified and directed. | 80 | Square Metre | 135 ₹10,800 | 200 ₹16,000 | 115 ₹9,200 Lowest |
| 5.00 | Demolition of cement concrete (any description, unreinforced) in existing sunken portion of WC/Floor trap including removing all debris complete all as specified and directed. | 92 | Cubic Metre | 150 ₹13,800 Lowest | 400 ₹36,800 | 150 ₹13,800 Lowest |
| 6.00 | 40mm dia (bore) GI pipe medium grade as in spout, fixed in repair complete all as specified and directed. | 24 | Running Metre | 355 ₹8,520 | 300 ₹7,200 | 240 ₹5,760 Lowest |
| 7.00 | PCC 1:5:10 type E2 using 40mm broken brick aggrgate as in filling in sunken portion of floor complete all as specified and directed. | 62 | Cubic Metre | 977 ₹60,574 | 900 ₹55,800 Lowest | 1,800 ₹1,11,600 |
| 8.00 | Water proofing treatment to sunken floors of bathroom/WC/kitchen etc. as given below, all as per manufacturer's instructions, complete all as specified and directed: -
(a) Cleaning the concrete surface of top of the RCC slab and peripheral beams of sunken portion by wire brushing & washing with water, cutting out cracks, if any, to 'V' section in existing RCC roof slab or terracing, cleaning out, wetting, grouting with PMC mortar.
(b) All brick joints and superficial cracks shall be repaired with polymer modified mortar using URP as admixture at the rate 10% of cement content
(c) PCC kerb and padding shall be laid to desired slope using waterproofing compound (payment shall be done separately under respective concerned items).
(d) 15 mm thick polymer modified mortar using URP as admixture at the rate 10% of cement content shall be applied on slope base and vertical surfaces.
(e) Sealing of all joints/ trap/WC/Soil pipe with approved sealing compound.
(f) The surface thus prepared shall be coated with two coats of Dr Fixit Hydrochem Super or equivalent in specified makes.
(g) A layer of open woven glass fibre mesh shall be laid over base and vertical surface of sunken area.
(h) Rendering 10 mm thick using polymer modified mortar shall be done over entire area.
(j) Curing the sunken portion with water for minimum 48 hours by ponding.
(k) Testing before filling of sunken slabs.
Note:- (i) For measurement area to be treated with compound only shall be measured.
(ii) Work shall be got executed through manufacturer/authorized applicator of manufacturer only. Contractor shall enter into necessary MOU between contractor, manufacturer and their authorized applicator before execution.
(iii) Every stage of work i.e. (a), (b), (c) etc shall be approved by GE. Only then next stage/layer shall be commenced.
(iv) Props to be placed at bottom of the sunken slab before starting the work. | 335 | Square Metre | 777 ₹2,60,295 | 500 ₹1,67,500 Lowest | 1,500 ₹5,02,500 |
| 9.00 | Demolition of brick work built in cement mortar including all quions, arches, pillars etc but excluding precast concrete articles and removal of debris complete all as specified and directed. | 68 | Cubic Metre | 135 ₹9,180 Lowest | 200 ₹13,600 | 150 ₹10,200 |
| 10.00 | Brick work with old size fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and directed. | 50 | Cubic Metre | 6,177 ₹3,08,850 | 4,200 ₹2,10,000 Lowest | 4,500 ₹2,25,000 |
Tender Value
₹9.4 Cr
EMD Value
₹8.0 L
Closing Date
29 Nov 2025, 6:00 pmClosed
Chief Engineer Chd Zone
HQ CE Chandigarh Zone N Area, Airport Road Chandigarh-160003
CA NO CE CHZ AMB T 14 2025 26 RESTORATION OF MD ACCN TO ARREST IMMEDIATE LEAKAGE AND SEEPAGE WITH ASSOCIATED WKS AT AMBALA CANTT UNDER GE S AMBALA
2025_MES_725934_1
CE CHZ/AMB/T-14/2025-26
Open Tender
Civil Works
Item Rate
365 days
Ambala
As per Tender Documents
9 documents required · 9 mandatory
₹3,000
GE S Ambala
₹8.0 L
Yes
17 Feb 2026
13 Aug 2025
1 Dec 2025
24 Oct 2025
29 Nov 2025
24 Nov 2025
13 Aug 2025 - 30 Aug 2025
Cutting holes super ficial area exc 400 Sq. cement mortar but not exc 0.10 sqm into or through brick walls built in cement mortar and making good in cement concrete 1:2:4 type BoQ as required complete all as specified and directed.
Taking up or down steel tubing and connections of 40 mm bore in pipe, including cleaning for re-fixing or removal from site complete all as specified and directed.
Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed .
Forming jambs, etc to openings, including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work; new work built in cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster on brick or stone walls including raking out joints hacking for key & scrubbing down with water etc complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150 mm dia pipe complete all as specified and directed.
Rendering 10 mm thick on fair faces of brick work or concrete surfaces, finished even and fair (without using extra cement) on walls in cement mortar (1:6), complete all as specified.
Rendering 15mm thick on fair faces of brick work or concrete surfaces, finished fair and even on walls in cement mortar (1:4), using liquid water proofing compound complete all as specified. NOTE:WPC will be measured and paid for separately complete all as specified and directed.
Rendering 5mm thick in cement mortar (1:3) on fair faces of ceiling, finished even and smooth without using extra cement complete all as specified and directed.
Rough cast plastering over and including 10 mm thick rendering in cement mortar 1:3 and while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel aggregate (which is generally of size between 6 to 12 mm depending on the texture required) mixed with coarse sand and cement in the ratio of 1: 1: 1 shall be applied and finished even. The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure that larger aggregates are thoroughly covered complete all as specified and directed. Rough cast plaster shall be applied as specified clause 14.22 of SSR Part-I
Supply only liquid integral water proofing comound ISI marked complete all as specified and directed.
Exhaust fan, PVC body white, AC single phase, 230V of size 250mm . with blades, frame and loovers including complete all as specified and directed making 250 mm size hole (square or round) in the wall and making good.
SPN distibution board 4 way, double door, IP 43, as per IS 8623 including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles /gland/gaskets, fixed in repair, complete all as specified and directed.
Surface excavation n. exc 30 cement mortar deep and averaging 15 cement mortar deep in soft/loose soil & getting out including clearing all grass vegetation, saplings, shrubs, brush woods under growth roots and trees, complete all as specified and as directed.
Demolition of cement concrete (any desciption, unreinforced) for existing sunken portion of WC/Floor trap including removing all debris from site to a distance exc 250 m but not exc 500m and deposited where directed including cleaning of surface with wire brushes and water complete all as specified and directed.
Two coats of white lime wash on old plastered surfaces of ceiling including preparation of surfaces complete all as specified and directed.
Two coats of cement base paint on newly plastered wall surfaces including preparation of surfaces over a coat of primer with alkali- resistant priming paint complete all as specified and directed.
Complete removal of existing treatment and applying two coats of cement base paint including preparation of surfaces and coat of primer with alkali- resistant priming paint complete all as specified and directed.
Demolition of mud in roof any thickness whether full thickness removed or part thereof including plaster & leaping complete all as specified and directed.
40mm dia (bore) GI pipe medium grade as in spout, fixed in repair complete all as specified and directed.
Preparation of old Plastered or un-plastered surfaces of walls cornices etc by brooming down or steel wire brushing, scrapping down smoke soot moulds, moss, efflorescence salts, treating oil and greasy spots etc and applying two coat of white wash on walls complete all as specified.
Demolition of PCC including WC and removal from sunken floor, cleaning top of the RCC slab and peripheral beams, and sunken portion as specified :- (i) Apply cement slurry to the surface @ 0.50 kg/sqm of cement mixed with acrylic based polymer modified cementitious composite compound @ 0.253 kg/Sqm and the surface will be allowed to air cure for 4 hours. (ii) Apply another layer of cement slurry to the surface @ 0.25 kg/sqm of cement mixed with acrylic based polymer modified cementitious composite compound @ 0.126 kg/Sqm and the surface will be allowed to air cure for 4 hours. (iii) Curing the sunken portion with water minimum for 48 Hrs by ponding. (iv) Paste 200 micron thick polythene film of approved make with approved adhesive to the treated sunken surface. (v) Joints/ trap/WC/Soil pipe shall be properly sealed with approved sealing compound. (vi) Testing of all traps & joints shall be done after sealing and before filling of sunken slabs . Also refer TD117 (C) for filling the sunken, filling the sunken floor with lean concrete 1:3:6 using cinder up to required depth but sorrounding of WC pan will be filled with lime concrete and finish the surface using 40 mm thick PCC 1:2:4 finished the surface even and rough to receive top layer complete all as specified and as directed. (Note : Props to be placed on the bottom of the sunken slab before starting the work).
5 mm thick cement plaster in cement mortar 1:3 as in soffits of slabs/Chajja/ Sunshade, finishing the plastered surface even & smooth w/o using extra cement complete all as specified and directed .
Two coats Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification including preparation of new plastered surfaces, complete as specified and directed.
Mild steel 10 mm dia and over TMT bar cut to length, bent to shape required including uding cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Mild steel 6-8 mm dia TMT bar cut to length, bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Three coats of white lime wash on new plastered surfaces of ceiling including preparation of surfaces complete all as specified and directed.
Applying two or more coats of 100 % premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS-15489:2004, alkali & fungal resistance, dirt restance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 ltre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm over new/Old surfaces complete all as specified and directed.
Complete removal of existing treatment on plastered surface of walls and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and directed.
Post construction anti-termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
PCC 1:5:10 type E-2 using 40mm graded stone agg regate, 75 mm thick as in sub base of floor complete all as specified and directed.
First quality, Non skid ceramic, coloured, rectified i.e. straight edge (locally known as joint free) tiles of size 600 x 600mm each and of thickness not less than 7mm, in skirting etc laid over & including uding 10 mm thick cement mortar (1:4) screed, set and jointed with tile adhesive with notched trowel and pointed in grout of matching shade of tiles, complete all as specified and directed.
MCB SP single pole, 240 volts, 50 Hz, 10 KA breaking capacity , 6 to 32 Amps, ISI marked, complete all as specified and directed.
Non skid coloured ceramic tiles 400 x 400 x 7 to 8 mm set & jointed with neat cement slurry & pointed in white/coloured cement to match the tiles laid over and including uding 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Machine Cut Kota stone slab 18-22 mm thick on vertical surfaces like riser of steps, skirting, in single piece (of length not more than 1200 mm) over & including uding 10 mm thick (average thickness) cement mortar (1:3) rendering and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (Mirror finish), complete all as specified and directed.
Glazed ceramic coloured tiles 450x350x7 mm thick on vertical surface such as skirting, dado etc laid over and including 10 mm thick backing coat plaster in cement mortar 1:4 complete all as specified and directed.
Reinforced Cement concrete type B0 1:2:4 ( 12.5 mm graded stone aggregate) stone aggregate as in chajjas etc complete all as specified and directed.
Machine cut Kota stone slab flooring 20-25 mm thick in skirting, dado and pillar, laid over & including 10 mm thick rendering in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (mirror finish) complete all as specified and directed.
Granite jet black shade, 18-20 mm thick, machine cut, machine polished, bedded and jointed with adhesive suitable for granite/stone & pointed with grout of matching shade including uding necessary cutting over & including uding 15 mm thick (average thickness) cement mortar (1:4) screed, as in cooking platform, shelves, RCC counters, window cills & similar situations, complete all as specified and directed.
Machine cut Kota stone slab flooring 18-22 mm thick, for staircase step in single piece (of length not more than 1200 mm), laid over & including uding 15 mm thick (average thickness) cement mortar (1:3) screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including uding rubbing and polishing (mirror finish) complete, including uding provn of two Nos 3x3mm grooves at tread of each step complete all as specified and directed.
Dubbing out average 10 mm thick on irregular surfaces of soffit of slab/chajjas/ sunshades etc in cement mortar 1:4 complete all as specified and directed.
Baroda Green marble, 18-20 mm thick, machine cut, (table rubbed & polished) bedded and jointed with adhesive suitable for granite/stone & pointed with grout of matching shade including uding necessary cutting over & including uding 15 mm thick (average thickness) cement mortar (1:4) screed, as in Tread of Stair case complete all as specified and directed.
Rounding to edges of stone (of any description) slabs one edge, such as in steps, cooking platform, window cill, jamb and other similar situations including rubbing and polishing (mirror finish), complete all as specified and directed.
Taking down shutters of any description exc 1 sqm eac
Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/Sqmm, modulus of elasticity 850 N/Sqmm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant complete all as specified and directed.
Dismantling old unserviceable cement concrete/PVC water tanks of capacity exc 250 ltrs & n.exc 500 Ltrs and supplying & fixing of PVC water storage tank 500 ltr capacity HDPE triple layered, white colour cylindrical type fixed and hoisted in position on roof at any height complete with inlet/outlet of 20 mm GI Pipe connection including locking arrangement, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20 mm dia and (Minimum weight 20 mm - 210 gms ) Note : (i) Inlet, outlet & wash out pipe will be measured paid for separately complete all as specified and directed.
h and nexc 2 Sqm each complete all as specified and directed.
Plain, solid, straight 2nd class Hard wood (Hollock) chowkhats and frames, wrought, framed rebated on solid, rounded or chamferred, put together with glue pinned at joints complete all as specified and directed.
Per Quintal
Dismantling of brick or terracing tiles of single layers on roofs including cleaning of bricks/tiles of unusable bricks/tiles from site, complete all as specified and directed.
Factory made single extruded WPC (Wood Polymer Composite) solid skelton shutter door shutter of 30 size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant complete all as specified and directed.
Factory made single extruded WPC (Wood Polymer Composite) solid door Frames/Chowkhat of size 125 x 65 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant. Note: For WPC solid door frames, minus 5mm tolerance in Dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and directed.
Windows fabricated from Rolled Formed GI Section made of Galvanised steel colour coated (PPGI Sheets) (Base steel as per IS 513 ‘’D’’ quality). Galvanised as per IS 277 with Zinc of 90 Gsm/SqMt w. PAINT: Pre-Painted sections should be with primer coat of epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick. GI Section of 0.58mm thick in Double rebate windows in which both glazed shutter and flymesh shutter, 75X 58mm outer frame, Mullion 74 x 53mm, Glazed shutter 48 x 22mm, Flymesh 42 x 21mm, Beading for Glass Fixing 12 x 12mm in fixed portion and the outer frame and mullions to have rebate for glazed/gauzed shutters the sections cut to length metre joined with corner PolyVinylChloride brackets centre mullion fixed with PolyVinylChloride Mullion caps. Glass of 4mm thick plain float glass fitted with rubber gasket in glazed shutter and wiremesh of Stainless steel of 36 guage to fix mesh in mesh shutter using VC Gypsum Drywall screws and Spoon profile of 0.58mm GI Sheet. Corners of the windows should be joined with corner brackets made of polyvinylchloride with CRCA of zinc phosphate coat. Each glazed shutter and fly mesh shutter shall be provided with SS Pivot Hinges 2 in each, PolyVinylChloride handle 1 in each and Powder coated Peg stay in Glass shutter.Window shall be provided with enamel paint MS Grill/Guard Bars made of 10mm horizontal MS Sq Bar welded to 6 x 12mm MS Flat at with holes at both vertical ends. Gap between the bars should not be more than 152 mm. Window frames shall be fixed to brick / concrete masonry by using nylon self expension caps & 75/100 mm MS screws after drilling in walls. VC Gypsum Drywall screws should be used while fixng corner brackets,stay,hinges,mullion caps of windows with suitable provision for Window complete all as specified and directed.
Windows fabricated from Rolled Formed GI Section made of Galvanised steel colour coated(PPGI Sheets) (Base steel as per IS 513 ‘’D’’ quality). Galvanised as per IS 277 with Zinc of 90 Gsm/SqMt w. PAINT: Pre-Painted sections should be with primer coat of epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 mi
crons thick. GI Section of 0.58mm thick in Double rebate windows in which both glazed shutter and flymesh shutter, 75X 58mm outer frame, Mullion 74 x 53mm, Glazed shutter 48 x 22mm, Flymesh 42 x 21mm, Beading for Glass Fixing 12 x 12mm in fixed portion and the outer frame and mullions to have rebate for glazed/gauzed shutters the sections cut to length metre joined with corner PolyVinylChloride brackets centre mullion fixed with PolyVinylChloride Mullion caps. Glass of 4mm thick plain float glass fitted with rubber gasket in glazed shutter and wiremesh of Stainless steel of 36 guage to fix mesh in mesh shutter using VC Gypsum Drywall screws and Spoon profile of 0.58mm GI Sheet. Corners of the windows should be joined with corner brackets made of polyvinylchloride with CRCA of zinc phosphate coat. Each glazed shutter and fly mesh shutter shall be provided with SS Pivot Hinges 2 in each, PolyVinylChloride handle 1 in each and Powder coated Peg stay in Glass shutter. Window shall be provided with enamel paint MS Grill/Guard Bars made of 10mm horizontal MS Sq Bar welded to 6 x 12mm MS Flat at with holes at both vertical ends. Gap between the bars should not be more than 152 mm. Window frames shall be fixed to brick / concrete masonry by using nylon self expension caps & 75/100 mm MS screws after drilling in walls. VC Gypsum Drywall screws should be used while fixng corner brackets, stay, hinges, mullion caps of windows complete all as specified and directed.
Ventilators fabricated from Rolled Formed GI Section made of Galvanised steel colour coated (PPGI Sheets) (Base steel as per IS 513 ‘’D’’ quality). Galvanised as per IS 277 with Zinc of 90 Gsm/SqMt w. PAINT: Pre-Painted sections should be with primer coat of epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick. GI Section of 0.58mm thick in Double rebate windows in which both glazed shutter and flymesh shutter, 75X 58mm outer frame, Mullion 74 x 53mm, Glazed shutter 48 x 22mm, Flymesh 42 x 21mm, Beading for Glass Fixing 12 x 12mm in fixed portion and the outer frame and mullions to have rebate for glazed/gauzed shutters the sections cut to length metre joined with corner PolyVinylChloride brackets centre mullion fixed with PolyVinylChloride Mullion caps. Glass of 4mm thick plain float glass fitted with rubber gasket in glazed shutter and wiremesh of Stainless steel of 36 guage to fix mesh in mesh shutter using VC Gypsum Drywall screws and Spoon profile of 0.58mm GI Sheet. Corners of the windows should be joined with corner brackets made of polyvinylchloride with CRCA of zinc phosphate coat. Each glazed shutter and fly mesh shutter shall be provided with SS Pivot Hinges 2 in each, PolyVinylChloride handle 1 in each and Powder coated Peg stay in Glass shutter. Window shall be provided with enamel paint MS Grill/Guard Bars made of 10mm horizontal MS Sq Bar welded to 6 x 12mm MS Flat at with holes at both vertical ends. Gap between the bars should not be more than 152 mm . Window frames shall be fixed to brick / concrete masonry by using nylon self expension caps & 75/100 mm MS screws after drilling in walls. VC Gypsum Drywall screws should be used while fixng corner brackets, stay, hinges, mullion caps of windows complete all as specified and directed.
Stainless steel butt hinges 100 mm long medium weight complete all as specified and directed.
Mild st
Stainless steel fabricated type handle 150 mm long complete all as specified and directed.
Stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (whereever required) and fitting the same with necessary stainless steel nuts and bolts complete including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc, of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed.
Steel dome 50 mm dia including uding polishing complete all as specified and directed by Engr-in-Charge complete all as specified and directed.
Steel cap 40 mm dia complete all as specified and directed by Engr-in-Charge complete all as specified and directed.
Factory made mild steel door shutter with frame, fabricated from of 1 mm thick MS sheet including uding provision of steel handle & locking arrangement by providing 04 leaver lock with duplicate keys (of make Godrej, Link or Harrison) & handle etc, (all as per Godrej pattern & detail shown on Drawing No. FD-1032 sheet 1/1 dt 25.9.93) including uding spray painting over a coat of red oxide primer and fixed the same on existing cupboard nitch with cement & sand mortar, complete all as specified and directed.
Stainless steel plate rack of standard size 900mmx750mm x250 mm (weight not less than 08 Kg) complete and fixing in repair with rawl plug and steel screws, complete all as specified and directed.
Stainless steel plate rack of standard size 900mmx750mm x250 mm (weight not less than Kg) complete and fixing in repair with rawl plug and steel screws, complete all as specified and directed.
Supply only 50 mm long cold rolled mild steel butt hinges medium weight complete all as specified and directed.
0.80 mm thick mild steel plain black sheeting as in covering to door shut ters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including uding round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required fixed in repair, complete all as specified and directed.
eel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including uding either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete of Fe 310-0 complete all as specified complete all as specified and directed.
Mild Steel Framed work such as Guard Bar/grill welded to window frame or fixed independantlys, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, cooler stand and similar work conforming to Fe.290.Gde-E-165 complete all as specified & directed complete all as specified and directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Painting to steel surfaces of any description not other wise described over 10cement mortar width or girth with two coats of synthetic enamel paint including preparation of old surfaces complete all as specified and directed.
Dismantling wooden boarding any description, fixed in any position with nails as in shelves of cup board and pelmets of any description complete all as specified and directed.
300 mm MS ordinary rat tail rod pattern springs including roller and roller plate fixed to wooden chwkhats or welded to angle iron door frames complete all as specified and directed.
Stainless steel curtain rod 25mm dia having wall thickness 1.6mm fixed with and including uding stainless steel decorative brackets, two lotto for each road length at both end, fixed in repair, complete all as specified and as directed by the Engineer-in-Charge.
Rubber strips 3 to 4mm thick & 65mm to 75mm wide fixed on bottom rail of door for covering gaps between door & floor to aviod entry of insects, dust complete all as specified and directed.
150 mm overall length of cover plate Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
LEAD FREE PVC Celuka ply 18mm thick (Minimum density 600kg/Cum) of both side plain white colour, fixed with stainless steel screws, solvent cement /adhesive to make kitchen /bed room cabinet sides top and bottom and shelves inside the cabinets complete as per manufacturer’s specifications complete all as specified and directed.
LEAD FREE PVC Celuka ply 18mm thick (Minimum density 600kg/Cum) of single side rigid lamination of approved colour and other side plain white colour, fixed with stainless steel screws, solvent cement /adhesive to make kitchen cabinet shutters and shelves complete as per manufacturer’s specifications complete all as specified and directed.
12mm thick LEAD FREE PVC Celuka ply (Minimum density 600kg/Cum) fixed with stainless steel screws, solvent cement /adhesive to make wall mount kitchen cabinet back and pull out drawer sides complete as per manufacturer’s specifications complete all as specified and directed.
Stainless steel 304 grade wire basket cutlery of size 370 x 485mm premium quality fixed in position complete all as specified and directed. Make : HETTICH, KAFF, GLEN, HARRISON and GODREJ
Running welding in repairs to hinges of steel window/pressed steel door and making good for opening of doors/window shutters thickness of metal to be welded exc 6 mm but n exc 9 mm complete all as specified and directed.
Auto closing hinges of size 35mm of 0 crank (KH–001) of 8 crank (KH–002) openable at 110 degree for kitchen cabinet shutters complete in all respect and fixed in position complete all as specified and directed . Make : HETTICH, KAFF, GLEN, HARRISON and GODREJ.
Per10 Running centimeter
Set of two
Post construction anti-termite treatment of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed.
Preparation of ex
Post construction anti-termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of Cement Concrete (unreinforced) as in G.F & paving n. exc. 15cement mortar thick (above or below G.L.) complete all as specified and directed.
300x300 mm & 10mm thick Vitrified Pavement tile in approved color & shade and in anti skid finish, set and jointed in neat cement slurry and pointed in white cement & pigment to match laid over and including 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed. (Note: Design/pattern shall be as approved by GE at the time of execution)
Vitreous China squatting pan of “Orissa Pattern” of size 580x440mm coloured with integral foo
trest fixed in repair complete including making good floors complete all as specified and directed.
Chlorinated PVC (CPVC) SDR-11 pipes 16 mm outer dia, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i.e fixing the pipe with clamps at 1.0 m spacing . this including jointing of pipe Supply & fixings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete all as specified and directed.
Chlorinated PVC (CPVC) SDR-11 pipes 16 mm outer dia, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i.e fixing the pipe with clamps at 1.0 m spacing . this including jointing of pipe Supply & fixings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete all as specified and directed.
Cutting chases, not exc half brick work pinning in making good to facings where required and pointing in cement mortar 1:3 to ends of edges of landings, steps, cills etc., and cutting chases for concealed water tubing and making good complete complete all as specified and directed.
Vitreous china wash down water closet pan (Pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe, P or S trap,) fixed in repair complete all as specified and directed.
PVC water closet seat cover , white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device fixed in repair complete all as specified and directed.
Pillars taps fancy type chromium plated cast copper alloy with capston head long screwed shanks of 15mm bore fixed in repair, complete all as specified and directed.
Brass CP WHB Mixer valve for mixing hot and cold water screwed down for 15mm dia iron pipe fixed in repair, complete all as specified and directed.
Health faucet ABS body with 1 metre long easy flex tube in chrome finish and wall hook fixed in repair, complete all as specified and directed. Make:- JAQUAR Continental series Cat No:- ALD-BLK-585.
JET fighter spray with flexible arm complete for EWC fixed in repair, complete all as specified and directed.
10 ltr capacity PVC valveless, syphonic action type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, 32 mm dia flush pipe fixed in repair, complete all as specified and directed.
Vitreous china wash hand basin white flat back of size 550x440mm including CI brackets, chromium plated waste coupling, waste pipe etc., fixed in repair, complete all as specified and directed.
Chromium plated toilet paper holder,fixed in repair, complete all as specified and directed. Make:- JAQUAR or equivalent in specified makes.
CP Water purifier RO Connecting piece for Water Bib Tap for inlet of RO complete all as specified and directed.
Two way angle valve cock chromium plated brass, fancy type,15 mm bore, complete all as specified and directed. Make:- L&K Cat pat NO:- 0327 or equivalent.
Two way bib tap chromium plated brass fancy type of 15 mm bore complete as all specified and directed of make JAQUAR continental series Cat no:-CQT23041 or equivalent in specified makes.
Chromium plated hand shower with 1.5 mtr long flexible tube complete all as specified and as directed by engineer in charge
CP wall mixer telephonic type complete all as specified and directed
CP wall mixer telephonic type , fixed in repair complete all as specified and directed
Corner glass shelf with CP stand complete all as specified and directed.
Towel ring square with round flange fixed in repair Make JAQUAR or Equivalent complete all as specified and directed.
posed brick wall surface by cleaning the surface with wire brush to remove all dirt/loose materials from the bricks and from the joints between the bricks. Prepared surface shall be then washed with diluted HCL acid (dilution ratio of 1:50) for three times in a day for two days. After acid wash surface should be allowed to be air dried for one day. Note : Further treatment over the surface so achieved will be carried out only after approval of the same by GE. Note:- This item shall be executed by authorised applicator only. for carrying out efflorescence treatment to exposed and prepared wall surface here–in–above in following sequence :– (a) Prime the prepared surface with one of the following product mixed with cement in 1:1 ratio as bonding agent :– (i) Pidicrete URP of M/S Pidilite (ii) Sika Latex of M/s Sika (iii) Nitobond SBR Latex of M/s FOSROC (b) Immediately after priming the surface PMM (Polymer Modified Mortar) shall be applied "BY HAND" while the primer is tacky. PMM should be prepared by mixing one of the following compounds in Cement Mortar 1:3 as per manufacturer's instructions :– (i) Pidicrete URP of M/S Pidilite (ii) Sika Latex of M/s Sika (iii) Nitobond SBR Latex of M/s FOSROC
Towel ring square with round flange Make JAQUAR or Equivalent complete all as specified and directed.
15 mm fancy type chromium plated fancy type bib tap long body with flange screwed down high pressure CP cast copper alloy with crutch or butterfly handle scrwed down suitable for 15mm bore pipe or union, fixed in repair, complete all as specified and directed.
15mm bore Gun-Metal, globe or gate valves, with iron wheel head, screwed down both end for iron pipe and fixed in repair, complete all as specified and directed.
15 mm fancy type chromium plated fancy type bib tap long /short body with flange screwed down high pressure CP cast copper alloy with crutch or butterfly handle scrwed down suitable for 15mm bore pipe or union, fixed in repair, complete all as specified and directed.
Stainless steel grating openable 100mm sqmm size with/without hole including fixing with white cement, fixed in repair, complete all as specified.
Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, of 15mm bore, fancy type, chromium plated with long shank and cup (Concealed type), fixed in repair, complete all as specified and directed.
Angle valve cock chromium plated fancy type 15 mm bore with flange, fixed in repair, make L & K code No 077A or equivalent complete all as specified and directed.
Fancy type shower rose 125mm dia size of Rim and 30cement mortar long CP brass pipe with swiwel joint, fixed in repair, in complete all as specified and directed.
Sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cement mortar wide with chromium plated guard and railing 60 cement mortar long complete all as specified and directed.
Soap dish any type, fixed to plugs with chromium plated brass screws,fixed in repair, complete all as specified and directed.
Sink with drainage board made of stainless steel 1mm thick, kitchen or laboratory, with plugs, washers and waste pipe including bedding in cement mortor to dwarf wall or cantilever brackets and connecting union to pipe overall size 915x460mm, bowl size 410x 330x160mm including all fittings ie CP waste coupling, waste pipe fixed in repair, complete all as specified and directed.
Chromium plated, towel rack, 20mm dia, D type, 60cement mortar long between flanges, fixed in repair, complete all as specified and directed.
PVC connections 15mm size with PTMT nuts, 450mm long, fixed in repair, complete all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in roofs, floors (other than ground floors) beams, slabs, staircases, landing, chajjas and similar suspended work for frough finished flat surfaces of concrete complete all as specified and directed.
Sink made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm including waste pipe, fixed in repair, complete all as specified and directed.
CI Nahani traps complete 75 mm bore outlet including jointing to waste pipe fixed in cement concrete type B1, 1:2:4 complete all as specified and directed.
PVC cabinet with looking mirror of size 350x450mm premium quality, complete all as specified and directed.
Concrete bed to drain pipes of 100mm bore including packing under and hauching against the sides of pipes after they are laid and tested in PCC 1:3:6 type C2 complete all as specified and directed.
110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls including dismantling of existing pipes of any description/ length complete all as specified and as directed..
PVC (SWR) 40 mm pipe type A single socket in any length with rubber ring joints laid in floors or trenches including dismantling of existing pipes of any description/ length complete all as specified and as directed.
PVC (SWR) bends 40 mm borecomplete all as specified and directed.
PVC (SWR) bends 110 mm bore complete all as specified and as directed.
PVC (SWR) bends 75 mm bore complete all as specified and as directed.
40 mm bore PVC (SWR) junction single T (equal or unequal), including uding jointing with solvent cement, complete all as specified and directed.
110 mm bore PVC (SWR) junction single T (equal or unequal), including jointing with solvent cement, complete all as specified and directed.
75 mm bore PVC (SWR) junction single T (equal or unequal), including jointing with solvent cement, complete all as specified and directed.
LED surface mounted bulk head luminaries 8-10W with min 800 lumen, industrial model IP65, aluminium housing, surge protection including driver & LED etc complete with all accessories connecting with copper conductor flexiable cable from celing rose to connector of the light complete all as specified and directed.
PVC (SWR) floor trap, plain with grating including jointing with solvent cement of outer dia metre outlet of 75 mm, fixed in repair, complete all as specified and directed.
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. of tank capacity n exc 500 Ltr complete all as specified and directed.
Demolition and breaking up 150 mm bore drain pipes (salt glazed stone ware pipes) set in cement mortar complete all as specified and directed.
Sink with drainage board made of stainless steel 1mm thick, kitchen or laboratory, with plugs, washers and waste pipe including bedding in cement mortor to dwarf wall or cantilever brackets and connecting union to pipe overall size 915x460mm, bowl size 410x 330x160mm including all fittings ie CP waste coupling, waste pipe fixed in repair, complete all as specified and directed.
110 mm bore PVC (SWR) vent cowl, fixed in repair, complete all as specified and as directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m deep as in soft/loose soil for foundation etc or for shaft walls, cesspit, manhole etc n.exc 10 Sqm on plan complete all as specified and directed.
Returning, filling in including spreading, levelling and well ramming in layers not exceeding 25 cement mortar in each layer in soft / loose soil complete all as specified and directed.
Removing excavated material and debries obtained from demolition to a distance exc 250 m but n exc 500 m and depositing where directed at a level n exc 1.50m above the starting point complete all as specified and directed.
Reinforced concrete pipes, class NP3, laid and jointed complete with collars of 150mm bore laid in trenches and jointed complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if require
Per Running Metre
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in roofs, floors (other than ground floors) beams, slabs, staircases, landing, chajjas and similar suspended work for frough finished flat surfaces of concretecomplete all as specified and directed.
d) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.(cleaning reparing etc measured separately), 500 litre complete all as specified and directed.
Demolition of cement concrete unreinforced of any description and in any position not otherwise specifically provided for complete all as specified and directed.
110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches complete all as specified and directed.
Salt-glazed stoneware gully traps,150x150 square or round mouthed, type "P" setting and jointing to drains with cement mortar 1:1 complete all as specified and directed.
Taking down chowkaths or frames not exc 1.5 sqm each and removing from the site including uding dismantling brick work for hold fasts complete all as specified and directed.
Sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 6.0 sq mm drawn in and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories on wall or ceiling with one additional PVC insulated, stranded copper conductor FRLSH of 6.0 sqmm, green colour for earth continuity conductor including uding including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed.
Single Pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps complete all as specified and directed.
Extra for forming fair finishing of drain or channel 30 cement mortar inner girth in cement concret using extra cement including forms, moulds mitrel gloppid ends complete all as specified and directed.
Wire brushing and cleaning the roof surfaces with water including flashings and junction of parapets complete all as specified and directed.
Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surface of wall and finished even and smooth with neeru finish to plastering complete all as specified and directed.
PCC 1:2:4 type B-1 (20mm graded stone aggregate) as in coping/ benching etc including necessary form work complete all as specified and directed.
Plain cement concrete 1:4:8 , type D-2 using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed .
Cleaning of sludge from the manholes by taking out loose sediment sand, girt, ash, sludge water, rags, fibres or vegetation etc. from manholes including removal of sludge/debris to a distance exceeding 250m but not exceeding 500m duly covered in an hygenic manner and buried under ground complete all as specified and as directed.
Precast concrete cover slabs for man hole/drain etc. in (1:2:4) type B-1 using 20 mm mechanically crushed graded stone agg complete all as specified and directed.
75 mm thick cement concrete 1:3:6, type C–1 (using 20mm graded crushed stone aggregates) as in plinth protection laid in alternate bays (n exc 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight , complete all as specified and directed.
PCC (1:3:6) C-1 using 20 mm graded stone agg as in surface channel or drain including use of necessary from work for fair finished surface complete all as specified and directed.
APP polymeric water proofing membrane minimum 3 mm thick and weighing not less than 3.0 Kg/Sqm black finish reinforced with non-woven polyster matt weight not less than 150 gm/Sqm with thermo fusable finish laid over compatible bitumen primer at the rate of 0.40 Ltr/Sqm, torching over laps with a propane or abutan gas torch with a over lap of 75 mm at the side and 100 mm at the ends and sealing including applying a coat of cold emulsion bituminious primer all as per manufacturers instructions including preparation of surface complete all as specified and directed. Note :- The water proofing treatment shall be got carried out by the manufactarer or their authorised applictor's duly approved by GE in writing complete all as specified and directed.
Plain cement concrete (1:2:4) type B-1, using 20 mm graded stone aggregates as in padding to roof to maintain the required slope and finished the surface even and smooth without using extra cement, complete all as specified and directed.
A coat of Heat resisting painting to surfaces of any description wood, steel, iron, concrete, brick, stone, APP surface, etc., exceeding 10cement mortar in width or girth including preparation of surfaces complete all as specified and directed.
PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) for benching, coving shall be 150 mm in radius mixed with acrylic based polymer water proofing compound, complete all as specified & directed.
Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on & including 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner complete all as specified and directed.
Dismantling timber scantling 40 Sq. cement mortar and over in section, in any position of unframed/ framed work complete all as specified and as directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium solid conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sq. mm nominal cross section in service connections, one twin core cable including all incoming and outgoing connection complete all as specified and directed.
Demolition of Concrete in ground floors and pavings n exc 15 cement mortar thickness complete all as specified and directed.
Rolled Mild Steel (Structural Steel Work) in roof Trusses (framed) , trussed purlins, crane gantries, rails and fastenings and heavy bracket framing ( Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and directed.
Rolled mild steel (Structural Steel Work) in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes including rivetting, welding etc complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc, fixed in repair, complete all as specified and directed.
TOTAL AMOUNT
Add or deduct for each 25 mm girth or part thereof over or under 30 cement mortar ditto complete all as specified and directed. (For rate purpose only)
Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and directed.
Dismantlling Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings in any position complete all as specified and directed.
Semi perforated false ceiling 12 mm thick with micro tegular edged at all height with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595 mm of approved texture, design and pattern having moisutre content less than 2%, humidity resistance of 99%, NRC 0.60 to 0.85 as per IS 8225-1987, non combustible as per BS 476 (Part-4) 1970 and light code description unit code No 429 Sub Head 26. New Technologies and materials reflectance of 85% minimum to be laid in true horizontal level suspended on interlocking metal T -grid of hot dipped galvanised iron section of 0.33 mm thick (galvanised @ 120 gms/ sqm including both sides) comprising of main T- runners of size 15x 32mm of length 3000mm, cross T of size 15 x32 mm of length 1200mm and secondary intermediate cross T of size 15 x 32 mm of length 600 mm to from grid module of size 600 x 600 mm, suspended form ceiliing using galvanised mild steel items (Galvanised @ 80 gm/sqm) i.e. hangers (GI wire of 4 mm dia) to be fixed by hiliti consisting of HLS sleeve anchor fastencer length and L shape level adjuster of size 85 x 25 x 2mm, galvanised iron perimeter wall angle of size 24 x 24 x 0.4 mm of length 3000 mm to be fixed on perimeter wall / partition with the help of plastic rawl plugs at 450 mm centre to centre and 40 mm long dry wall SS screws including dismantling existing asbestos/PVC/ metal / Gysum sheet false ceiling textile coverings including frames (if any) and cover fillets complete all as specified and directed. NOTE : - Unit rate quoted against this item shall also including taking down and refixing the same of any electrical board, switch, sockets, light and fittings, fans etc after carrying out necessary relevant work and making good to match with existing surface affected for this area etc complete all as specified and directed.
Taking down old unserviceable single phase Electric Meter and deposited to MES Store Yard complete all as specified and directed.
Taking down old and unserviceable submain wiring any size /type including earth wire complete with batten/conduit etc complete all as specified and directed
Taking down old Water Heater (Geyser) any type/Size/Capacity with all accessories after removing of all incoming/outgoing pipe line connection and deposited to MES Store Yard for repair complete all as specified and directed.
Taking down old unserviceable VPTN MCCB DB//MCB SPN 8way any of size/capacity complete all as specified and directed.
Taking down old unserviceable MCB SPN/MCB SP of any size/capacity complete all as specified and directed.
Hard core of broken stone or boulders, gauge n exc 63mm, deposited, spread and levelled in layers n exc 15cement mortar thick, watered and rammed to a true surface, complete all as specified and directed.
100mm thick cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggregate) as in sub base complete all as specif
Taking down carefully aluminium/ copper point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of walls,ceilings etc complete all as specified and directed.
Taking down ceiling fan any size or any type and deposited to MES store yard complete all as specified and directed.
Taking down exhaust fan any size or any type and deposited to MES store yard complete all as specified and directed.
Fixing only exhaust fan and connecting up including provision of cable from ceiling rose/connector to fan complete all as specified and directed.
All as per srl item No 10 above but point wiring for one Plug & socket (independent) controlled by one MCB with using 4.00 Sq mm (nominal area) stranded copper conductor for Geyser complete all as specified and directed.
Point wiring in conduit using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH PVC insulated and unsheathed stranded cable drawn through and including uding PVC non metallic/mettalic heavy duty concealed/Surface conduit and including replacement of its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI sunken boxes made out of 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paint over a coat of red oxide primer internally and externally including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over sunken box for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan/Exhaust fan point contorlled by one switch including uding 1.5 sqmm single core PVC insulated and unsheathed FRLSH copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan Point controlled by one switch complete all as specified and as directed. NOTES : - (a) Switch, socket and fan regulators to be measured and paid for separately. (b) Cost of cutting/chases for concealing of conduit shall be deemed to be included in quoted rate. All chases will be cut by mechanical chase cutter only.
All as per item No 221 here in before but for socket out let point 5 Amps on same board complete all as specified and directed.
Per Point
Per Point
Modular switch 1 way 6A, 1 module , 230 volt , AC supply, ISI Marked, fixed in repair, complete all as specified and directed.
All as per item No 221 here in before but for socket out let point 5 Amps on independent board complete all as specified and directed.
Modular switch 2 way 6 Amps, 1 module, 230 volt , AC supply, ISI Marked, fixed in repair, complete all as specified and directed.
All as per item No 221 here in before but for one two way point controlled by two switch complete all as specified and directed.
All as per item No 221 here in before but for one bell point controlled by one bell push complete all as specified and directed.
All as per srl item No 221 above but point wiring for one socket out let 15 & 5 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed.
MCB SP single pole, 240 volts, 50 Hz, 10 KA breaking capacity , 40-63Amps, ISI marked, complete all as specified and directed.
MCB SPN 40 -63 Amps rating ,240 volts, 50 Hz, breaking capacity 10 KA complete all as specified and directed.
Taking out old unserviceable earthing and material & labour for earthing with Galvanised Steel earth plate electrode 60cement mortar x 60cement mortar x 6.0 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cement mortar thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Earth lead wire 4.00mmdia (upto terminal point) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40 mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including uding excavation and earth work in any type of soil , returning, filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 1991(Part-I) complete all as specified and as directed by Engineer-in-charge. Note : The rates for earth work, GI protection pipe, funnel, wire wesh, CI cover, etc shall be deemed to be including uding in quoted rates complete all as specified and directed.
Hanging only ceiling fans and connecting up including uding provision of cable from ceiling rose or connector toceiling fan including cleaning and minor repair and replacement of split pin, hook and rod/pipe of required length with fixing arrangement etc complete all as specified and directed.
Sheet steel enclosure with separate busbar chamber for cable termination with and including MCCB four pole, 240 volts, 50Hz , breaking capacity 16KA, 100 Amps, thermal release type, complete all as specified and directed.
Fixing only single phase electric meter any type and any capacity with all accessories with making all connection ccomplete all as specified and directed.
Post top lantern LED 30W, cast aluminium spigot, with high effieient LED light, with poly carbonate diffuser, complete with high efficient LED lamp 30 W and accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
TPN distibution board 4 way, double door, IP54, IK 09
LED light fitting 9/12 W wall mounting fixture (Sketch type) suitable for retrofit LED lamp B22 compact and energy efficient epoxy powder coated light luminaire including disconnecting and taking down existing unserviceable light fittings of any description complete all as specified and directed.
as per IS 8537 including uding 200 Amp fully insulated copper bus bar, including MCB TPN 63 Amp, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles /gland/gaskets ccomplete all as specified and directed.
Surface mounted wall Mirror LED light compact & sturdy 10W LED decorative fixture with anti glare polycarbonate diffuser, multi purpose lighting solution & applications all accessories & fixtures, internally prewired and connecting by providing copper flexiabkle wire 2/0.0076 mm twin core upto fitting complete all as specified and directed.
Modular switch 1 way, 16A,1 module, 230 volt , AC supply, ISI Marked, fixed in repair, complete all as specified and directed.
Modular socket outlet 6A-3 Pin combined, 2 module, 230 volts ,ISI Marked, fixed in repair, complete all as specified and directed.
Modular fan regulator 1/2 modules, 120W, 50 Hz, AC supply suitable for ceiling fan any type/make/sweep fixed in repair, complete all as specified and directed.
Call bell ding dang /musical type single pole fixed in repair, complete all as specified and directed.
Removing building materials etc (other than spoil payable under items 03028 to 03031 in section 3-Earthwork) to a distance of 100m or under beyond the lead including uded in the rates including loading, unloading and stacking at the destination complete all as specified and directed.
Fixing only geyser 25 Ltrs in position, connecting to existing electric & water connections and testing at site complete all as specified and directed.
Ceiling rose surface bakelite 65x50mm, 3 terminal fixed in repair, complete all as specified and directed.
Lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
ISON and GODREJ.
Modular socket outlet 6/16 A-3 pin combined 2 modules, 230 volts ,ISI Marked, fixed in repair, complete all as specified and directed.
LED light fitting 1x20W, 220V, not less than 100 lumen per watt, AC with aluminium housing with batten type with driver, holder including 20W LED tube light, connecting up with three core flexiable copper conductor cable of suitablae size from celing rose to connector complete all as specifid and directed. Note: LED cool white/warm white shall be as by engineer- in- Charge approved complete all as specified and directed.
Supply and fixing or passing through pipe, PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. Mm, 3 ½ core complete all as specified and directed.
Modular bell push, 6 Amps one module, 230V,50Hzs, AC supply fixed in repair, complete all as specified and directed.
Sch of Credit
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.28 MB
BOQ_812674.xls
BOQ • 0.56 MB
FinalTender.pdf
Tender Documents • 2.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .