| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.5 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹44.0 L+₹3.4 L (8.33%)Rejected-Finance REVATHY TC 79 1020 3 SREE RAGAM ROAD KARIKKAKOM KARIKKAKOM PO THIRUVANANTHAPURAM 695021 | THIRUVANANTHAPURAM | KERALA | 695021 | L2 | Rejected-Finance Quoted rates higher than L1 bidder | |
| 3 | L3₹45.1 L+₹4.5 L (11.0%)Rejected-Finance | L3 | Rejected-Finance Quoted rates higher than L1 bidder |
Tender Value
₹47.8 L
EMD Value
₹95,500
Closing Date
27 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF TRIVANDRUM
CWE AF TRIVANDRUM HQ SAC IAF COMPLEX AKKULAM THURUVIKKAL POST TRIVANDRUM 11
Addn Altn to Bldg No P 4 at 17 FBSU at AF Stn Trivandrum
2022_MES_547090_1
CWE(AF)TVM/82426E8 Addn Altn P4 at TVM
Open Tender
Civil Works
Item Rate
180 days
Trivandrum
Class D category a(i)
6 documents required · 6 mandatory
₹500
GE AF Trivandrum
₹95,500
Yes
28 Oct 2022
23 Aug 2022
29 Sept 2022
23 Aug 2022
27 Sept 2022
13 Sept 2022
24 Aug 2022 - 3 Sept 2022
Amount
SCHEDULE 'A'
Dismantling floor/wall tiling including cement mortar ( but not backing) removing of unserveable tiles from site and rubbish of the premises complete all as specified and directed.
Screed bed or bedding layer of mortar 15mm thick in CM 1:6 for laying floor finishes complete all as specified and directed.
Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm (600X600mm), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm (300X300mm), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Rendering 10mm thick in CM 1:4 to wall as a backing coat to dados/skirting complete all as specified and directed.
S&F 200x300x7mm/300x450x7mm thick coloured designed ceramic tiles in vertical surfaces etc . Set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Same as item no 4 above but vertical surface such as skirtings, matching to the floor complete all as specified and directed.
Taking down chowkats or frames n.exc 1.5 sqm each with shutters (without taking off shutter from the frames) complete all as specified and directed.
Taking down chowkats or frames exc 1.5 sqm but not exc 4 sqm each with shutters (without taking off shutter from the frames) complete all as specified and directed.
M&L for Forming jambs, etc. to openings (to foregoing item),with CM 1:6, including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified and directed.
M&L for Making good under cills or over arches, lintels and bressummers.with CM 1:6 including all pinning when necessary complete all as specified and directed.
S/F anodised aluminium powder coated frame for door, windows & partitions with one or more rebates including joining cleat for fixing etc complete all as specified.
S/F anodised aluminium powder coated door shutters,side hung/ sliding type without sash aluminium sections weighing 0.55 kg/mincluding necessary joining cleats,glazing clips rubber packing anodised aluminium snap beading, screws,anodised aluminium fittings such as handles 2 Nos,hinges complete all as specified.
Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified.
S&F SS Mortice lock, vertical type, 4 levers ,size 100 mm fixed complete all as specified.
S/F anodised aluminium powder coated window shutters fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
S/F anodised aluminium powder coated ventilator shutters,side hung type without sash aluminium sections weighing 0.55 kg/mincluding necessary joining cleats,glazing clips rubber packing anodised aluminium snap beading, screws,anodised aluminium fittings such as peg stays 150mm long (1no.),hinges type B-21 100mm long (2no.),suitable handle(1 no.)complete all as specified.
S/F anodised aluminium powder coated sliding window shutters without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings etc. complete all as specified and directed.
Sheet glass, 4mm thickness ordinary quality and glazing with aluminium staples and rubber beading in square n exc 0.5 sq. m in each pane complete all as specified and directed.
Sheet glass, 4mm thickness ordinary quality and glazing with aluminium staples and rubber beading in square exc 0.5 sq. m in each pane complete all as specified and directed.
M&L for 9 mm thickness Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination , fixed with screws / aluminium clips to aluminium frame work like door and partition complete all as specified and as directed.
Demolition of PCC cement concrete in groung floor and paving n.exc 15 cm thickness below or above ground level complete all as specified and directed.
Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth for laying of cable and not exceeding 10 Sqm on plan for poles, struts, stays etc. and not exceeding 1.5 m in depth and getting out complete all as specified.
M & L for cement concrete type D2, 1:4:8 (40 mm graded aggregate) cement concrete in foundations filling and mass concrete etc complete all as specified and directed.
M&L for Pre-cast cement concrete block masonry with solid blocks type C1 , 1:3:6 using 20mm graded aggregate, exc. 10 cm in width and setting in mortar 1:4, complete all as specified and directed
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key scrubbing down with water etc complete all as specified and directed.
M&L for Rendering 15mm thick in CM 1:6 to brick work or concrete surface finished even and smooth with out using extra cement complete all as specified and directed.
M&L for preparing old plastered surface and applying two coats of distempering to walls with distemper oil emulsion complete all as specified and directed.
M&L for preparing new plastered surface and applying two coats of distempering to walls with distemper oil emulsion complete all as specified and directed.
M&L for preparing old plastered surface and applying two coats of white wash to walls complete all as specified and directed.
M&L for preparing new plastered surface and applying three coats of white wash to walls complete all as specified and directed.
M/L MS Framed work such as guard bars; barred iron doors, gate, ladders, railings, framed cable duct and cover with checker plates etc including proper welding etc complete all as specified and directed.
M&L for preparation of new steel surfaces of any description and applying two coats of synthetic enamel paint over a coat of appropriate primer complete all as specified
M&L for preparing old plastered surface and applying two coats of white wash to ceiling complete all as specified and directed.
Preparation of old surface on wood or wood based surface of any description over 10cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed.
M & L for preparation of old plastered surfaces of wall and applying one coat weather proof coat paint complete all as specified and directed
Taking up or down GI tubing incl connections of 20 mm dia bore complete all as specified and directed.
Taking up or down GI tubing incl connections of 15mm dia bore
S&F medium grade galvanised iron 20mm bore with all fitting and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
S&F medium grade galvanised iron 15 mm bore with all fitting and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
Demolition and breaking up drain pipes complete all as specified and directed.
S/F PVC(SWR)75mm borepipes single socketed in any length with rubber ring joints fixed to walls/floor complete all as specified and directed.
S/F PVC(SWR) 110mm borepipes single socketed in any length with rubber ring joints fixed to walls/floor complete all as specified and directed.
PVC (SWR)bend 110mm bore
PVC (SWR)bend 75mm bore
PVC(SWR) bend 110mm bore with access door
S&F in repairs Vitrous china wash down water closet (EWC)excluding cystern, seat cover and internal fittings including jet spray.
PVC water closet seat closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
Supply and fix 10 Litre capacity PVC low level flushing cistern with ball valve and handle/push button 32mm dia PVC flush pipe including taking down unserviceable cistern complete all as specified and directed.
Supply and fixed in repairs vitreous china ware wash hand basin 550mm x 400 mm size, white, flat back or angle including removing the existing one complete and refixing with new bracket as in repairs and making good all connections.
Supply and fix 32 mm dia bore waste fittings brass chromium plated fixed to wash hand basin with long screwed shanks and fly nuts flange and bedded in run lead cement and other end fixed complete.
Supply and fix in repairs 15 mm bore bib tap brass chromium plated fancy type with crutch or butterfly handle screwed down, screwed for iron pipe fixed in repairs all as specified and directed.
S&F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
PVC floor trap plain with grating incl jointing with solvent cement. Dia of outlet 75mm complete all as specified and directed.
Supply and fix 15mm bore pillar taps CP brass chromium plated fancy type screwed down high pressure with chromium plated screwed shanks and fly nuts complete screwed for iron pipe in repairs all as specified and directed.
S&F brass CP shower rose with arms 75 mm size fixed to pipe all as in repairs specified and directed.
S & F 20 mm dia tubular towel rail brass cromium plated, D type,60cm long between flanges including one pair of brackets all as in repairs specified and directed.
S&F in repairs angle valves, 15 mm dia cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed all as specified and directed by Engineer-in-Charge .
S&F Stop valves,15mm dia ,fancy type, chromium plated with long shank and cup (concealed type) , screwed both ends for iron pipe or for unions and fixed in repair
M & L Anodised aluminium snap grid frame work of size 605 X 605 mm fixed with Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified for false ceiling complete all as specified and directed.
M & L PVC insulation panels 10mm thickness with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium complete all as specified and directed.
Roughning surfaces of old concrete floor by pocking seepint clean and washing down with water to remove dust etc complete all as specified and directed.
Brushing neat cement slurry with 3 kg of cement per sqm complete all as specified and directed.
M/L cement concrete type B-0 1:2:4 using (12.5mm graded agg averaging 40mm thick) complete all as specified and directed.
M&L cement plastering in CM 1:3, 10mm thick on RCC roof surface finish even and smooth without using extra cement and with using water proofing compound complete all as specified and directed.
Supply only Liquid water proofing compound
M&L for water proofing treatment on horiontal or vertical surface with provision of oil bond bitumen primer @ 0.20 kg per sqm and applying a coat of blown grade hot bitumen 85/25 or 95/15 @ 1.2 kg/sqm and providing 4mm thick APP modified water proofing membrane weight not less than 4 kg/sqm reinforced with non woven polyester matt weighing not less than 160 gm/sqm as per detailed specifications and finished with solar reflective bituminous aluminium paint @ 100gm per sqm complete all as specified and as directed.
Removing building materials and un serviciable construction materials etc to distance 1 Km outside the MOD land including loading, and disposal etc complete all as specified and as directed.
M/L cement concrete 1:2:4 type B0 using (12.5mm graded agg) 25mm thick as in levelling course for flooring complete all as specified and directed.
Taking down old / deface cement plaster on brick , concrete or stone walls etc including racking out joints, hacking for key scrubbing down with water and Rendering 15mm thick in CM 1:6 to brick work or concrete surface finished even and smooth with out using extra cement with using GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste ,to prevent joint cracks etc etc including necessary scaffolding if required as directed by E-in- Charge complete all as specified.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification including hinges , handles & Tower bolts all as directed by Engr-in- Charge.
M&L for Providing precast reinforced cement concrete type B1 1:2:4 (using 20mm aggragate) in win- dow or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar 1:4 complete ( Reinforcement shall be measured separately under respected items)
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Ditto as per item No 76 above , but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
S&F Temporary steel props including wooden planks at the top of props if required to make even and rigid surface to support existing roof slab as per the direction of Engineer in Charge
M&L for demolition of Brickwork or stone/ boulder masonry, built in cement mortar complete all as specified and directed.
M&L for provisioning of Synthetic flooring with 5mm thick synthetic roll over screed bed motar 15mm thick in CM 1:6 over cement flooring 25mm thick type B0 1:2:4 (using 12.5mm aggregate) installation as per the instruction of manufacturer , complete all as specified , screed bed and flooring concrete will measured and paid seperately under respect items .
M/L cement concrete 1:2:4 type B0 using (12.5mm graded agg) 25mm thick as in levelling course for flooring and finishing cement concrete surface even and smooth with using extra cement.
Shifting of existing Addressible fire alarm control panel from existing location to new location including programming complete all as directed.
Taking down and disconnecting existing Addressible multi sensor detector and Shifting to new location and making necessary connection complete all as directed.
M & L for replacement of Addressable single action Manual pull station resettable type having an integrally mounted addressable module that monitor and report contact status
Taking down and disconnecting existing Addressible single action Manual pull station and Shifting to new location and making necessary connection complete all as directed.
M & L for replacement of Addressable horn/strobe wall mounted type rated at 82 dBA @ 3m for Audible announciation and 75 cd flashing at 1 Hz for visual indication
Taking down and disconnecting existing horn/strobe wall mounted type and Shifting to new location and making necessary connection complete all as directed.
M & L for replacement of fire alarm cable stranded copper conductor, XLPE insulated ,cores laid up, PVC inner shethed, GI wire armoured and FRLS PVC outer shethed 2 core 1.5 Sqmm copper fire cable fixed on wall/ roof /existing cable tray with necessary cable glands as required complete confirming to IS standards all as specified and directed.
Removing Existing Split AC 1.5/2.0 ton including indoor and outdoor unit and stabilizer complete and refixing in new location including water servicing, spray painting of outdoor and indoor unit with approved paint, provision of additional cable and copper pipe as per site requirement, wall mounting bracket, filling of refrigerent to the required quantity and necessary PVC drain pipe complete including testing and commissioning all as directed.
Supply,install, testing and commissioning of split ACs with inverter type comprising of indoor/outdoor with copper coil single phase 230V, 50Hz complete with cordless remote control unit of high EER rated BLDC compressor, including necessary fixing arrangement complete unit shall be placed at suitable position and height inside the room and outdoor unit at suitable place outside the room on plinth height / on wall or roof as suitable and including metallic bracket with fixing bolts for outdoor unit,required copper piping, insulated piping etc.,of suitable Refrigerant cpapcity 2 TR (copper type) 5 star rated complete all as specified and directed. Make : Blue star/Voltas/LG
Supply & Fix metal plug and socket single phase two pin and earth plug with MCB, SP 25 Amps and steel enclosure all as directed.
Supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 270 V with output voltage stabilized at 230 V with accuracy of ± 2.5%, low and high voltage cut-off protection, latest IC technology with intelligent time delay system of capacity 5 KVA complete all as specified and directed.Make : V Guard VGB 500 or equivalent
M&L for sub main wiring surface type including with (2 runs of 6 Sqmm for phase and neutral and one run of 6 Sqmm for earth continuity) 1100 Volts grade PVC insulated unsheathed single core multistranded cable FRLS grade with copper conductor confirming to IS 694 drawn in conduit including provision of suitable dia of PVC rigid conduit (medium grade) with conduit accessories such as bends, elbows, saddles all as specified and as directed.
Supply and fixing hevy duty digital LCD Disply auto AC change over timer switch for cyclic operation of two ACs of 30Amps, 230V all as specified and directed.
M&L for Point wiring with 1.5 sqmm single core PVC insulated FRLSH cable 1100 volts grade with copper conductor drawn in and including PVC conduit and all conduit accessories concealed and including provision of 1.5 sqmm PVC insulated copper cable FRLSH as earth continuity conductor fabricated branded Modular metal flush box concealed in walls with Modular suitable plate with cover with suitable screws for housing switches socket outlets fan regulators etc all as specified and directed for the following :-
(a) One switch socket outlet 5 Amps on independent board
(b) One light point controlled by one one way switch
(c) One fan point controlled by one switch and regulator.
All as per Item No 96 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable FRLSH including 2.5 sqmm PVC insulated copper cable as earth continuity conductor for one switch socket outlet 15 Amps on independent board all as directed.
S&F Switch Modular type single pole oneway 5 amps all as specified and directed.
Supply & Fix modular socket 3 pin 5 Amps flush type all as specified and directed.
S&F Switch Modular type single pole oneway 15 amps all as specified and directed.
Supply & Fix modular socket 3/5 pin 5/15 Amps flush type all as specified and directed.
S&F Fan step regulator, 120W - 2 module
M&L for sub main wiring surface/ concealed type with 2 runs of 6 Sqmm for phase and neutral and one run of 6 Sqmm for earth continuity 1100 Volts grade PVC insulated unsheathed single core multistranded cable FRLSH grade with copper conductor confirming to IS 694 drawn in and including provision of suitable dia of PVC rigid conduit (medium grade) with conduit accessories such as bends, elbows, saddles including cutting chases and making good in CM 1:3 complete all as specified and directed.
Supply, fixing and connecting up complete MCB DB SPN 4 way double door, 230 V, AC, 50 Hz, for MCB SPN as incomer and MCBs SP as out going, IP-43 protection conforming to IS-13032 universal mounting with copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides complete all as specified and directed. Make : Legrand/ Schneider Electric/ Havells
S & F Sheet Metal Enclosure for MAIN DBs, Triple Pole & Neutral, 4 Way , 415 Volts with 100 Amps rated neutral bus bar double door vertical type, IP-43 protection conforming to IS-13032 universal mounting with copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides complete , grouting the DB and making good the disturbed surfaces with extra cement without any additional cost suitable for TP/SP outgoing to accomodate and including MCCB 100A 16 KA as incoming all as specified and directed. Make : Legrand/ Schneider Electric/ Havells
S&F MCB SPN 32 Amps 415 V 50 Hz with repturing capacity 10kA all as specified and directed.
S&F MCB SP 6 to 32 Amps 230 V 50 Hz with repturing capacity 10kA all as specified and directed.
Supply and fix new energy efficent LED Box type fitting 1 x 20 watts 4 feet long CRCA body powder coated white batten type MCL LED type all prewired including connection with twin core flexible PVC 0.5 Sqmm complete Make: Havells cat No.LUMILINEPLUSBS20WLED865SPCSS or Philips cat No. BN021LED20S PSU CW GR S2 or Wipro Cat No.LL20-221-XXX-65NE3
S&F recess mounted square slim 600 x600mm (2'X'2) LED Luminaire of 36 watts including connection with twin core flexible PVC 0.5 sqmm cable complete all as specified and directed.
S&F Industrial plug socket combination 2 pin and earth plug complete controlled with MCB 32 A and fixed on wall all as directed.
Supply and fix Exhaust fan 380mm sweep heavy duty 1400 RPM single phase 240 volts AC 50 Hz with louvers and connecting up with and including provision of cable 3 core of size 0.5 sqmm (16/0.2mm) from ceiling rose to fan including writing MES No.2 cm height with synthetic enamel black paint all as specified and directed. Make - Havells/Orient/Crompton/Usha
Supply and fix and connecting up BLDC ceiling fan 5 Star rated of size 1200mm sweep complete with downrod and electronic regulator including provision of cable 3 core of size 0.5 sqmm from connector to fan, provision of 3mm thick PVC sheet cover including writing MES No 2cm height with synthetic enamel black paint all as directed. Make :Havells/Orient/Crompton/Usha
Supply & fix Air Circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting. Make :Havells/Orient/Crompton/Usha
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised iron wire of 4 sqmm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR connected to earthing test point all as specified or indicated complete with excavation & earth work, PCC pit with 50mm thick RCC cover (grade M-15) having suitable handle (10mm MS Rod) 20mm dia GI medium grade watering pipe with GI funned with wire mesh 15mm bore GI pipe (light grade) forprotection of earth lead conductor all as directed and testing on completion.
Supply and fix ceiling rose 3 phase PVC/Polycarbonate isolated body all as specified and directed.
Supply & fix single pointed air termination aluminium rod 12mm dia, 300 mm long
Supply & fix aluminium strip 25mm x 3.15mm complete with saddles and fixing screws etc, for roof conductor/down conductors above ground and connect with test point all as specified and directed.
Supply & fix GI strip 32mm x 6 mm buried in ground
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised iron strip of size 32x6 as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR connected to earting test point all as specified or indiealed complete with excavation & earth work, PCC pit with 50mm thick RCC cover (grade M-15) having suitable handle (10mm MS Rod) 20mm dia GI medium grade watering pipe with GI funned with wire mesh 40mm bore GI pipe (light grade) forprotection of earth lead conductor all as directed and testing on completion.
S&F Test terminal block made of gun metal or phospherous bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex. Head screw.
Supply and lay in trenches/fixed to wall, GI tubing light grade of 40mm dia for protection of earth conductor all as specified and directed..
Shifting of existing LT panel from AFNET room to new location after disconnecting all the cables and refixing in new location including provision of cable glands, PCC platform as per requirement, minor spares required for the proper installation of LT panel and testing after completion all as specified and directed.
Supply and lay in trenches/road crossing/wall etc, cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 V grade with stranded aluminium conductor confirming to IS 7098/1985 ISI marked including necessary glands, lugs etc of following sizes all as specified and as directed.
(a) 3.5 Core 95 Sqmm
(b) 3.5 Core 50 Sqmm
Returning and filling of excavated soil up to a depth of 30 cm after riddling the excavated soil for Cushioning of cable and refilling of trench with normal excavated soil all as specified and directed.
Removing excavated material to a distance not exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point.
Supply and lay sub class 'B' old size bricks laid in trenches for protection of cables all as directed
Supply and lay in trenches/under roads/crossings or fixed to wall/pole, GI tubing light grade of following sizes for protection of UG cables.
(a) 80mm dia
(b) 50mm dia
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthling etc. 20x3mm copper strip
Supply,fixing,testing and commissioning of indoor type Isolation Transformer of capacity 75KVA, K Rated,three phase,copper wounded input voltage 415Volt,out put voltage 415Volt system, Model-core type, oil cooled,input frequency 50Hz,operating humidity 0-95% non condensing, class of insulation 'H',thermal with standing 65 degree + ambient, max temperature 120 degree,linear harmonic attenduation 100%, non linear harmonic attenduation more than 90%, vector group DY 11,Impedence 4-5%, HV Capacity 2.5KV from primary to secondary, primary to earth and secondary to earth, grade of lamination M4 0.27 grade complete all as specified and directed.
Supply, installation, testing and commissioning of maintenance free grounding solution set comprising of High tensile low carbon steel rod of 3 mtr lengith and 17.2 mm dia with 250 micron (average) molecularly bounded copper on the outer surface to confirm with requirements of UL 467 including suitable copper earth termination clamp alongwith back fill compound of 30 Kgs strictly be a carbon based conductive concrete type which has a fixed carbon content of more than 99 % and resistivity of less than 0.12 Ohm Mtr as per clause 14.5 D of IEEE, 80 standard back fill compound should be electronically conductive (Like in metals) and should not depend on moisture for conduction, size of bore 80 mm dia, 12 feet depth, distance between the each bore 3 mtr and carbon steel rod shall be inter connected with 25 mm x 3 mm size copper strip including brazing / welding arrangement complete including Earth pit cover made of Heady duty polyplastic and earth inspection cover made of high grade polypropylene of size top dia not less than 250 mm, bottom dia not less than 330 mm and height not less than 260 mm dia having load bearing capacity not less than 8 tonnes for each electrode pit complete all as specified and as directed .
Total of Schedule 'A'
DEFT GROUP ELECTROMECHANICAL
M/s G.Ramachandran
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .