Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 CrAccepted-AOC 121 MODEL TOWN AMBALA CITY HARYANA 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | ₹3.1 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹3.9 Cr+₹76.5 L (24.3%)Rejected-Finance | ₹3.9 Cr+₹76.5 L (24.3%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹4.6 Cr+₹1.5 Cr (46.1%)Rejected-Finance | ₹4.6 Cr+₹1.5 Cr (46.1%) | L3 | Rejected-Finance NOT LOWEST |
Tender Value
₹3.4 Cr
EMD Value
₹4.1 L
Closing Date
27 Feb 2023, 6:00 pmClosed
HQ CE (AF) WAC PALAM
HQ CE (AF) WAC PALAM
WORK SERVICES FOR ENHANCEMENT OF SECURITY INFRASTRUCTURE AT AF STN AMBALA
2022_MES_555185_1
CEWAC/AMB/T-20/2022-23
Open Tender
Civil Works
Lump-sum
450 days
GE (P) (AF) AMBALA
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
GE (P) (AF) AMBALA
₹4.1 L
Yes
24 Apr 2023
7 Oct 2022
6 Mar 2023
7 Oct 2022
27 Feb 2023
13 Feb 2023
7 Oct 2022 - 21 Oct 2022
Amount
SCHEDULE `A' PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only.
Construction of Guard Rest Room on permanent specification, complete all as specified and shown on drawings (with raft foundation).
Construction of Sub Guard Room on permanent specification, complete all as specified and shown on drawings (with isolated footing).
Construction of Sentry Box on permanent specification, complete all as specified and shown on drawings.
Construction of Watch Tower With Guard Rest Room on pemanent specification, complete all as shown on drawings.
Construction of Septic Tank for 10 Users complete all as specified and shown on drawings.
M&L Soakage Well of size 1.20m x 3.00m effective depth, complete all as specified and shown on drawings.
NOTE: Schedule ‘A’ Part II to X below are Prepriced by MES.
Lump sum price worked out by the Contractor for “EXCAVATION AND EARTH WORKS” as listed in Schedule ‘A’ Part II
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION WORKS” as listed in Schedule ‘A’ Part III
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL WORKS" as listed in Schedule ‘A’ Part IV
Lump sum price worked out by the Contractor for "AREA DRANAGE WORKS” as listed in Schedule ‘A’ Part V
Lump sum price worked out by the Contractor for “ROAD,ROAD REPAIR & WIDING OF ROAD WORKS” as listed in Schedule ‘A’ Part VI
Lump sum price worked out by the Contractor for “WEATHER SHELTER WORKS” as listed in Schedule ‘A’ Part VII
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY WORKS” as listed in Schedule ‘A’ Part VIII
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION WORKS ” as listed in Schedule ‘A’ Part IX
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY WORKS” as listed in Schedule ‘A’ Part-X
SCHEDULE `A' PART - XI MISC B/R & E/M ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only.
S & F LED security light 15 watt, input 110 to 220 volts, as per IP 55 luminaries comprising of rectangular shape , high pressure die cast a!uminiurn housing, with weather proof gaskets for lamp and driver compartment with G! pipe 25 mrn dia light grade bend to shape including necessary fixing arrangement complete all as specified and directed.
S&F walI mounted bulk head liqht cornplete in all respect of 9 Watts, complete all as specified and directed.
S & F energy efficient LED Flood light 120 Watts 230 \/, 50 Hz with ingress protection IP-66 with CRCA housing including fixing arranoement like clamp, nuts & bolts, washers etc, complete all as specified and directed.
S & F energy saving high bay LED light fitting surface mounted 100 Watts 230 V indoor type including all fittings, accessories and wires, complete all as specified and as directed.
S & F wall mounted fan 300mm, sweep complete incl control of fan speed & Swing with rope, 230 volts (single phase) and providing or flexible copper cord three core PVC insulated & overall sheathed of size 0.50 Sqmm of required length, complete all as specified and as directed.
S & F MCB SPN 32 Amps, B curve type 10 KA, 240 Volts complete. complete all as specified and directed.
S & F MCB SPN 20 Amps,B curve type 10 KA, 240 Volts complete all as specified and directed.
S&F MCB SP 6 to 32 Amps, B Curve type 10 KA breaking capacity 240 Volts complete all as specified and directed.
S & F straight through Joint kit for 1.1 KV grade suitable for indoor/ outdoor type terminal heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 50 Sq mm complete all as specified and directed.
S & F straight through Jointing kit for 1.1 KV grade cable for indoor/ outdoor termination, heat shrink type, joint complete with Jointing material and accessories suitable for 4 core XLPE armoured, Al conductor cable of size 25sqm, complete all as specified and directed.
S & F TPN DB of 4 way for MCB TPN as a incomoming and single phase as well as SP/TP MCB as a outgoing with IP 43 protection and 01 K 09 protection against machanical impact DB should be as per IS 8623 and made of high quality CRCA sheet DB should be insulated Busbar 200 A withstand capacity 36 KA, shrounded neutral busbar, door earthing corner safe wire sets.Neutral bar, earth bar and wire ties should come along with DB complete all as specified and as directed.
S & F MCB TPN 60 Amps, C curve type 10 KA Breaking capacity 415 Volts complete all as specified and as directed.
S & F MCB TPN 40 Amps, C curve type 10 KA Breaking capacity 415 Volts complete all as specified and as directed.
S & F energy efficient LED Flood light 120 Watts 230 V, 50 Hz with ingress protection IP-66 with CRCA housing including fixing fixing arrangement like clamp nuts bolts etc washers complete all as specified and directed.
S & F energy efficient LED Flood light 250 Watts input voltage 230 V, 50 Hz with ingress protection IP-66 with CRCA housing including fixing arrangement like clamp, nuts bolts, washers etc complete all as specified and directed.
S & F energy efficient LED street light fittings(Beamer) 90 Watts input voltage 230 V, 50 Hz with ingress protection IP-66 with CRCA housing including fixing arrangement like clamp, nuts bolts, washers etc, complete all as specified and directed.
S & F pole mounting juction box of size 140 mm x 140 mm x 95 mm fabricated out of 2 mm thick MS sheet, front openable door with hinges, duly painted with aluminium paint internally and externally over a coat red oxide primer suitabe to house and including 4 Nos aluminium bus Bars of 63 amps capacity mounted on suitable insulators, one No MCB SP 6 Amps mounted on dinrail, internally wired with suitable size of copper conductor cable, provision on bottom side for cable entry holes incl fixing with steel tubular poles with two nos of Fl clamps 25mm x 3mm with nuts, bolts and washers complete and making connection with 1.5 mm copper conductor unsheathed FRLS PVC insulated 3 core from junction to security light fittings duly laid inside the steeI tubular pole and bracket complete all as specified and directed.
S & F PVC insulated and overall sheathed three copper conductor cable of size 1.5 sqm drawn through steel light pole/pipe of security light fittings complete all as specified and directed.
M & L for bracket for fixing of street light fittings bent to shape, made out of 40mm dia GI pipe medium grade not less than 1.5 mtrs long two branch fixed with two sets of MS clamps made out of flat iron of size 50 x 6 mrn fabricated to shape and fixed with nuts, bolts and washers & two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed
S& F time switch astro type (Having longitude and latitude of Indian cities in memory) supply votage 110-240 Volt AC, 50 Hz three phase of 20 Apms rating LCD display with contactor fitted inside steel enclosure complete all as specified and directed
S & F security light bracket made out from GI pipe light grade of size 40mm dia bent to shape having length 1.2 meter including flat iron clamp made of Fl 40 mm x 6 mm, nuts, bolts, washers etc duly painted with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Cutting the exiting DI/CI/GI pipe line upto 80 - 100 mm dia size for fixing of tee/bend etc of pipe for branch connection complete all as specified and as directed. Note :- Excavation & earthwork shall be measured and paid separately under respective items
M & L for CI/DI fitting complete all as specified and directed complete all as specified and as directed.
M & L construction of brick masonry valve pit of size 90 x90 x 105 cm (internal dimension of chamber) with brick work in cement mortar 1:4 including plastering internally and pointing externally as the work proceeds complete wrth MS sheet cover 3.15mm thick and angle iron frame 40 x 40 x 6 mm with handle, locking arrangement and painting with two coats of synthetic enamelled paint over a coat of red oxide primer on steel surfaces including earth work & excavation in any type of soil, disposal of surplus spoil not exceeding 50m etc, complete all as specified and shown on drawings.
SOM BUILDERS
A K BANSAL AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .