| 1 | L1₹29.8 LAccepted-AOC 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.5 L+₹63,794 (2.14%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L2 | Rejected-Finance L2 | |
| 3 | L3₹30.8 L+₹90,771 (3.04%)Rejected-Finance 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L3 | Rejected-Finance L3 | |
| 4 | L4₹31.2 L+₹1.3 L (4.45%)Rejected-Finance | L4 | Rejected-Finance L4 |
Tender Value
₹29.4 L
EMD Value
₹58,760
Closing Date
20 Jun 2022, 6:00 pmClosed
GE (AF) CHILODA
GE (AF) Chiloda, Lekawada Patia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
SPECIAL REPAIR TO CHANGE IN OLD CEMENTED POLE WITH STEEL TUBULAR POLE, SPECIAL REPAIR TO BER E/M APPLIANCES AND PROVN OF ELECTRIC CABLE FOR AC IN SMQ AREA AT AREA B AF STN WADSAR UNDER GE AF CHILODA
2022_MES_525843_1
8815/2022-23/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
WADSAR
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) CHILODA
₹58,760
Yes
6 Aug 2022
23 May 2022
22 Jun 2022
23 May 2022
20 Jun 2022
6 Jun 2022
23 May 2022 - 5 Jun 2022
Amount
Taking down of existing serviceable street light from RCC Pole and refixing on steel tubular pole bracket after cleaning and connecting PVC wire till looping box complete all as specified and directed. Note:-PVC wire for connection will be measured and paid separately
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Dismantling concrete pole/struts any size carefully to avoid any damage to nearby objects complete all as specified and directed.
Supply and errecting steel tubular pole in replacement of RCC poles with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) duly painted internally complete and externally painted with two coat of aluminium paint complete all as specified and directed. Note: Earth work /excavation / PCC shall be measured and paid separately.
S&F in replacement of mounting bracket forming Cap type having an interior angle of 120 degree made out of GI pipe light grade 40/50 mm dia as per LED light required for fixing to street light fittings on the poles not less than 1.5 meter long duly painted with aluminium paint two coats complete all as specified and directed.
S&F in repair PVC wire 1.5 sqmm 3 Core PVC insulated cable copper drawn from looping box to street light fitting terminal complete all as specified and directed.
M & L for Writing letters or figures (Block.Roman, Italic or Indian) n exc. 30 cm high complete all as specified and directed.
S & F Radium sticker red colour water proof 80 mm wide around the poles complete all as specified and directed.
S&F in repair of looping box (enclosures) of size 280 x 170 x 130 mm made of PVC comprising of 02 Nos aluminium bus bar 100 Amps rating fixed on porcelain insulators, earthing terminal and one MCB SP 6 Amp including MS bracket, nut an bolts complete all as specified and directed.
M&L for excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc. and getting out soft/ loose soil complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layer not exceeding 25cm complete all as specified and directed.
Removing excavated materials not exceeding 50 mtrs away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supply and laying clean dry sand for cable cushioning including gently punning down complete all as specified and directed.
M&L for old size , burnt brick, sub class 'B', laid in trenches, abutting each other with a gap not exceeding 10 mm , vertically over the cable for cable protection complete all as specified and directed.
Supply and laying or fixing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cable (H/D) earthed cable aluminium conductor, 1100 volts grade with standed complete all as specified and directed for 10 sq. mm, 2 core nominal cross section in service connections.
Taking up/down of old unserviceable UG LT cable up to 16 Sqmm, 2 core of any type from trenches etc complete all as specified and directed.
S&F 40 mm bore GI tubing, light grade galvanized with all fitting and laid in trenches complete all as specified and directed.
M & L for boring of holes up to 80 mm dia under road pavement, hard standing, etc by trench- less technology using ultra sound technique complete all as specified and directed by Engineer-in- charge. Note:- Pipe for protection of cable shall be measured and paid separately.
Supply and fixing GI pipe Light grade 50 mm bore (ISI marked) laid in trenches/ path /road crossings/ fixed to poles/ceiling/ along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required, complete all as specified and as directed by the Engineer-in-Charge. (Note:- Necessary excavation and earth work shall be measured and paid for separately)
M & L PCC 1:3:6 type C2 using 40 mm graded stone aggregate in foundation of pole complete all as specified and directed.
M & L PCC 1:3:6 type C1 using 20 mm graded stone aggregate in coping of pole etc including necessary form work complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and paving, plinth protection n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
S&F in replacement Nature Switch complete pole mounted enclosure consisting of MCBs, Power Contactor and SMC Enclosure conforming to IP 54) for encasing full 1- phase circuit board along with Nature Switch-01, Model No SWADEEP – 02EC 3kW1P (for 3-5kW load equally distributed over 1-phase) complete all as specified and directed by Engr-in-charge.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick electrode, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to 4 mm dia galvanized earth wire by means of bolts, nuts, check-nuts and washers of galvanized iron or steel all as shown in electrical plate No 5 (duly protected with 15 mm dia light grade GI pipe upto 7.5m from the earth plate) and connected to GI steel earth plate including charcoal, dust, common salt, necessary excavation in soft/loose soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m from the starting point, watering pipe 20 mm bore GI tube of light grade treated with 1 No PGI funnel, pit of PCC 1:2:4 type B-1/ RCC 1:2:4 type B-1, pit cover 75 mm thick reinforced with 6 mm dia bars @ 75 mm c/c both ways and with MS handle 12 mm dia connected to earth test point including testing complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6.3mm burried directly in ground level with teop edge of earth plate at a depth not less than 1.5m below ground level connected to and including galvanised iron strip 25 x 6mm as earthing lead by means of bolts, nuts, check nuts and washers etc made of GI and connected to earthing test point all as shown in electric plate No.3 of SSR indicated and testing on completion including excavation and earth work in any type of soil/rock, PCC (1:3:6) type C-1 earthing chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforce with welded steel wire babric (APM) weight not less than 4 Kg/Sqm, funnel with GI watering pipe of 20mm bore medium grade, wire mesh and lugs, GI protection pipe of 40mm bore medium grade 7.5 m long test point etc complete all as specified and directed.
Supply, laying & testing cable XLPE insulated, screened ,PVC bendded galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade, of size 25 sq mm. 3.5 core complete all as specified and directed.
Supply, laying & testing cable XLPE insulated, screened ,PVC bendded galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade, of size 185 sq mm. 3.5 core complete all as specified and directed.
M & L for straight through joint 1.1 KV for XLPE U/G cable Heat Shrink type of size 4x120-185 Sq mm complete all as specified and directed.
M & L for straight through joint 1.1 KV for XLPE U/G cable Heat Shrink type of size 4x25-50 Sq mm complete all as specified and directed.
S & F MCCB 4 Pole 63 Amps, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and directed.
S & F MCCB 4 Pole 160 Amps,50 Hz,415 V with rupturing capacity 36 KA complete all as specified and directed.
S & F MCCB 4 Pole 200 Amps,50 Hz,415 V with rupturing capacity 35 KA complete all as specified and directed.
M&L for concealed sub main wiring of two run with 2.5 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit and accessories of suitable size and fixed on concealed surface of wall/ceiling with cutting chases where required including one run of 2.5Sqmm single core PVC insulated, FRLS , flexible copper cable as earth continuity conductor in green color complete all as specified and directed.
S& F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed.
Supply and fixing SPN 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 150 KVA, Variac with Buck Boost transformer type Micro Controller based digital display Input : 3P MCCB with all Electronic tripping facility included first filling oil included upto required level complete all as specified and directed. Note:- (i) Rating 150 KVA, 3 Phase, 4 wire with bypass switch and phase sequence correction system (ii) Input Frequency Ranges : 47 Hz to 63 Hz (iii) Duty cycle :- 24x7 Hrs (iv) Suitability :- suitable for all power factor loads (v) Class of Insulation :- F Class (vi) Efficiency 97-99% (vii) Input/Output Termination On Copper Bus Bar (viii) Drive Direct AC drive for fastest voltage correction and durability (ix) Controls All the three phases controlled individually for better voltage and load management on micro processor controlled digital display
Supply of 20 KVA 3 Phase Silent DG Set comprising of Water Cooled 28BHP engine. (LATEST CPCB-2 COMPLY ENGINE) coupled to 20KVA / 16 KW, 415V alternator mounted on a common base frame along with other accessories i.e. Fuel tank, Battery with leads with AMF Panel (LATEST CPCB-2 COMPLY ENGINE)3 Cylinders, Inline, 4 Stroke Cycle, Liquid Cooled, Developing28 Bhp @ 1500 RPM, under NTP Condition of BS: 5514. The engine shall be provided with electrical starting arrangements and shall give electrical output of 20 KVA / 16 KW @ 0.8 lagging power factor, 415V. at alternator terminal. 1. Radiator 2. A1 class MECHANICAL Governor 3. Battery Charging Alternator 4. Engine safety Sensors (LOP & HWT) 5. Air Cleaner 6. Lube Oil Filter 7. Fuel Filler 8. First fill of Lube oil and Radiator Coolant Single bearing alternator suitable for continuous operation of generating 20 KVA / 16 KW @ 1500 RPM,415V., 0.8 Lagging Power Factor suitable for 50 Hz, 3 Phase, 4 Wire System confirming to BS 5000 / IS 4722. The alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator has the following features (i)+/- 1.0 % Voltage regulation (max) in static condition (ii) IP 23 protection with insulation class “H” (iii)Permissible overload of 10% for one hour in 12 hours of operation
DIGITAL MANUAL CONTROL PANEL: Digital Manual is equipped with 16 bit high speed RISC Processor based DES-9 controller. It displays the following Parameters Voltage , Frequency, Current, Rpm,Cumulative Run Hours, Oil Pressure Coolant Temperature , Charging Current (DC Amp Meter), The DES -9 Processor Provides the following safety to the engine: Under & Over Voltage, Under & Over Frequency, Under & Over Speed, Overload, Low Lube Oil Pressure, High Coolant Temperature, Emergency Off ACOUSTIC ENCLOSURE: (i) Silent DG Set enclosure is of modular construction with the provision to assemble & dismantle easily as per site condition. Lifting arrangement is also an integral part of the enclosure. (ii)There are no protruding parts. (iii) The enclosure is fabricated out of CRCA sheet of 16 SWG. (iv) The fuel level is indicated with the help of fuel gauge meter. (v)Battery is accommodated in a separate tray in the enclosure. (vi)The doors are gasketed with high quality EPDM gaskets to avoid leakage of sound. (vii)The door handles are lockable type. (viii) Sound Proofing of enclosure is done by high quality imported PU fire resistant foam of 25 mm thickness. (ix) A special residential silencer is provided with the enclosure to control exhaust noise. (x)Specially designed alternators are provided to control sound at air entry to the container and exist from the container.
(xi)To make system vibration free, engine & alternator is mounted on specially designed anti-vibration pads. (xii)Adequate ventilation is provided to meet air requirement for combustion heat removal. (xiii)Temperature of enclosure does not exceed beyond 5 degrees of ambient temperature. (xiv)Noise level is 75 dB (A) at 1 meter distance. The enclosure meets the norms as specified by CPCB. ACCESSORIES: Fuel Tank: Daily service fuel tank of sheet metal of suitable size complete with air vent, inlet and outlet connections. BATTERIES: One Nos. batteries of 12 volts each in dry and uncharged condition of Exide / Prestolite or equivalent make with its leads. Note:- (i)Phase –I and Phase –II test will be conducted in Presence of IEM before installing DG set. (ii) Residential type silencer with MS pipe as designed by OEM horizontal exhaust pipe complete with bend& flanged of adequate length not less than 10 mtr along with thermal insulation on horizontal type with mineral wool/asbestos rope 50 mm thick wire mess and 26 gauge aluminum cladding 12 inch
Schedule of Credit
ALBA AC AND REF SERVICES
ARTI CONSTRUCTION
SANVI ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .