Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹88.8 LAccepted-AOC | ₹88.8 L Quoted ₹88.9 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹91.8 L+₹3.0 L (3.33%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | ₹91.8 L+₹3.0 L (3.33%) | L2 | Rejected-Finance 2nd Lowest bidder |
| 3 | L3₹1.0 Cr+₹15.8 L (17.8%)Rejected-Finance 1 A BASEMENT 30 31 RAJA HOUSE NEHRU PALACE NEW DELHI 110 019 | SOUTH EAST | DELHI | 110019 | ₹1.0 Cr+₹15.8 L (17.8%) | L3 | Rejected-Finance 3rd Lowest Bidder |
| 4 | L4₹1.3 Cr+₹36.8 L (41.4%)Rejected-Finance SPECIAL 1 INDUSTRIAL ESTATE NEW POWER HOUSE ROAD JODHPUR 342003 | JODHPUR | RAJASTHAN | 342003 | ₹1.3 Cr+₹36.8 L (41.4%) | L4 | Rejected-Finance 4th Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
26 Nov 2022, 6:00 pmClosed
AMIT KUMAR PARMAR
GEIPAF TEZPURE MILITARY ENGINEER SERVICE AIRFORCE STATION GORAI MARI SONITPUR ASSAM 784104
PROVN OF EXTERNAL POWER SUPPLY TO CENTRAL AIR CONDITIONING PLANT OF CERTAIN BLDGS UNDER GE (I) (P) (AF) TEZPUR.
2022_MES_560629_1
8134/E8
Open Tender
Civil Works
Item Rate
180 days
GE(I)(P)(AF) TEZPUR
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,000
GE (I) (P) AF TEZPUR
₹1.6 L
31 Dec 2022
31 Oct 2022
28 Nov 2022
1 Nov 2022
26 Nov 2022
14 Nov 2022
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc. 25 cm complete all as specified and directed
Removing of surplus excavated soil to a distance not exc. 50 m and deposited where directed at a level n exc 1.5 m above the starting point all complete all as specified and directed.
M & L for sand cushioning with dry clean Sand to underground cable 23cm thick (8 cm thick before laying and 15 cm thick after laying the cable) punned to 18cm all as specified and directed. (Note:Punned thickness shall be measured and paid)
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M & L for plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
Material and labour for cross arms, bracing, supports, clamps and back plate fabricated from structural steel section including nut, bolts, washers, welding, bending, cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 2 with , size of 300mm x 180mm x 40mm complete all as specified and as directed.
Supply and laying un-reinforced precast concrete cable cover class HV, Type-1 with size 300mm x 180mm x 40mm complete all as specified and as directed.
Supply, laying & testing cable XLPE insulated screened , PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, 11000 volts earthed, grade cross sectional area 120 Sq mm 3 core complete all as specified and as directed.
Supply, laying & testing cable XLPE insulated screened , PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, 1100 volts earthed, grade cross sectional area 630 Sq mm 3.5 core including inserting stainless steel gland and crimping aluminium lugs of cable size complete all as specified and as directed.
Supply, laying & testing cable XLPE insulated screened , PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, 1100 volts earthed, grade cross sectional area 400 Sq mm 3.5 core including inserting stainless steel gland and crimping aluminium lugs of cable size complete all as specified and as directed.
Supply, laying & testing cable XLPE insulated screened , PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, 1100 volts earthed, grade cross sectional area 300 Sq mm 3.5 core including inserting stainless steel gland and crimping aluminium lugs of cable size complete all as specified and as directed.
Supply, laying & testing cable XLPE insulated screened , PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, 1100 volts earthed, grade cross sectional area 240 Sq mm 3.5 core including inserting stainless steel gland and crimping aluminium lugs of cable size complete all as specified and as directed.
Supply, laying & testing cable XLPE insulated screened , PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, 1100 volts earthed, grade cross sectional area 185 Sq mm 3.5 core including inserting stainless steel gland and crimping aluminium lugs of cable size complete all as specified and as directed.
Supply, laying & testing cable XLPE insulated screened , PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, 1100 volts earthed, grade cross sectional area 120 Sq mm 3.5 core including inserting stainless steel gland and crimping aluminium lugs of cable size complete all as specified and as directed.
M&L Cable jointing kit 11kv (E)grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured cable of size 120 sqmm complete all as specified and directed
M&L Cable jointing kit 11kv (E) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured cable of size 120 sqmm complete all as specified and directed
M&L Cable jointing kit 11kv (E) grade cable for straight throgh cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured cable of size 120 sqmm complete all as specified and directed
Supplying , fabricating and installing of 300 mm (50 mm x 1.6 mm thick ) hot dip galvanised ladder type cable tray including horizontal ,vetical bends, reducers, tees , cross members and other accersries as required and duly installed from ceiling/side walls with suitable sizes of chennels/angles with anticorrision painting full thereaded GI rods etc.complete all as specified and directed
M & L for cable route indicator for HT cable with 35x35x4mm MS angle iron post 1.00 Mtr long embedded in PCC 1:3:6 type C1 foundation concrete 150mm x 150mm x 300mm deep complete all as specified and directed
M&L for danger notice plate of 1.6mm thick 25x20cm size mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HTcable complete all as specified and as directed.
Supply & Laying of 100 mm bore GI tubing light grade laid under floor or walls/poles/under road or trenches bore either by boring or laying in trenches for road crossing etc for Cable protection complete all as specified and as directed.
Horizontal boring across the road, pavement, hard standing etc. for insertion of GI pipe up to 100 mm bore pipe for passing of electric cable through GI pipe depth not less than 1.0 from GL. complete all as specified and directed.
Earthing with copper plate electrode of size 60 cm x 60 cm x 3.15 mm thick, burried directly in ground (earth pit not less than 2.25 mm below normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level connnected to earth lead of size 20 X 3 mm copper strip by means of bolts, nuts, check nuts and washer of galavinised iron or steel including electric arc welding the earth strip connected to earthing test point incl galvanissed steel protection pipe 20mm bore for protection of earth lead , PCC pit ot type C2 (1:3:6) precast RCC cover with frame 20mm bore light grade galvan ised steel pipe for watering with funnel and wire mesh for watering, charcoal or coke and common salt in alternative layers of 15 cm compacted thickness all around the earth plate and testing on completion including all earth work in any type of soil and disposed of sorplus soil to a distance n. exc 50 m complete all as shown in electrical plate No 3 of SSR Part I all as specified and directed.
Earthing with GI plate electrode of size 60 cm x 60 cm x 6 mm thick, burried directly in ground (earth pit not less than 2.25 mm below normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level connected to earth lead of size 32 X 6 mm GI strip by means of bolts, nuts, check nuts and washer of galvanised iron or steel including electric arc welding the earth strip connected to earthing test point incl galvanised steel protection pipe 20mm bore for protection of earth lead , PCC pit ot type C2 (1:3:6) precast RCC cover with frame 20mm bore light grade galvanised steel pipe for watering with funnel and wire mesh for watering, charcoal or coke and common salt in alternative layers of 15 cm compacted thickness all around the earth plate and testing on completion including all earth work in any type of soil and disposed of sorplus soil to a distance n. exc 50 m complete all as shown in electrical plate No 3 of SSR Part I all as specified and directed.
S & F 32 X 6 mm GI strip earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe complete all as specified and as directed.
S & F 20 X 3 mm copper strip earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe complete all as specified and as directed.
Supply, install, testing and commissioning of Transformer floor mounted capacity 500 KVA step down, outdoor type 11/0.433 KV, 50 Hz, AC double wound core type copper wound, oil immersed, ONAN type cooling with external cooling tubes, transformer delta connection on HT side and star connection on LV side in accordance with vector symbol DyN-11 (vector group 4) and having tapping of ± 7.5% in equal step of 2.5% .The voltage regulation shall be as per IS including first fill of transformer oil as per IS-335 and including all fittings/accessories as specified in SSR Part-1 and IS-2026 the transformer should have cable box on LT side and bras bushing on HT side. The limit of temp rise after continuous full load run as specified in SSR Part-1 and shall be suitably adjusted to suit the maximum ambient temp prevailing at site all as specified comprising with and including the following specifications :- i) 01 No Cable box on LT side consisting lof 03 Nos porcelain bushing with bushing brass rods and nuts washers and cable glands of suitable for reception of cable LT 1100 Volt grade XLPE insulated heavy duty including gland joint complete. ii) HV bushing with arching horn on 11 KV side. iii) Oil conservator with filter type drain valve and oil level guage. iv) Explosion Vent. v) Thermometer Pocket. vi) Two Earthing Terminal on tank body. vii) One No Thermometer Dail Type vapour pressure type having range 0-120 degree centigrade with maximum temperature indidator and re-setting device to maximum temperature including needle of temperature gauge : Max reading painted terminal. viii) Rating plate with terminal marking plate. ix) Oil level guage. x) Oil drain filter valve. xi) Oil filling port on top cover with plug. xii) Air release valve/plug. xiii) 4 Nos plain solid cast steel detachable rollers. xiv) First fill of transformer oil conforming to relevant IS and tested upto 60 KV dielectric strength. xv) Inspection cover. xvi) Lifting lugs and jack lifting pad support. xvii) Explosion vent with duble diaphragm and sight glass. xviii) Silica gel breather or with connecting pipe, first fill of dehydrating agent. xix) Hand hole of sufficient size to assess the interior of the tank. xx) Cover lifting eyes. xxi) Oil temp indicator / winding temp indicator of approved range, including shut off valve between conservator and main tank. xxii) Extra bushing for neutral out side the LV side. Note:- a. The transformer shall be tested as routine test as per IS 2026 in presence of GE/ his rep. b. The contractor shall submit QAP (qualilty assurance programme) within 15 days after placement of order for transformer tesing at factory. Transformer shall be dispatch only after inspection clearance by inspecting officer. c. The contractor/ manufacturer shall furnish original MILL certificate (paid voucher and test certificate) of the CRGO manufacaturer. d. The manufacaturer / contractor shall furnish the diameter of LV and HV copper winding and its total resistance. The stray losses shall be specified in percentage terms. The percentage of NO load and full load losses shall be as per IS 2026. e. The contractor shall get the approval of GE for the make of the transformer they plan to procure. f. Prior to manufacturing the general arrangement drawing desighn details of the transformer shall be got approved by GE. g. Separate neutral bushing shall be brought out for earthing.
Supply, installed, testing and commissioning of outdoor type automatic power factor correction LT capacitor bank panel board , duly powder coated RAL 7035, 200 KVAR 6 stages (2 x 12.5 +1 x25 + 3 x 50) for 3 phase, 415 V & 50 Hz System having following accessories including controlled wiring with HR/FRLS copper wire and suitable foundation / plateform work complete all as specified and directed:- (i) Compact modular bolted desigened, removable side and back panel with option of top and bottom cable entry. (ii) Capacitor installed in removable assemblies for ease of operation and maintenance. (iii) Suitable capacity of MCCB as Incomming of APFC Panel with high electralyte grade Bus Bar of suitable rating, (iv) MDXL/LTXL capacitor of 12.5 KVAR-02 Nos, 25 KVAR-01 Nos, 50 KVAR-03 Nos with heavy duty capacitor duty contactor with coil voltage 230 V, 50 Hz and branch protection MCCB's/ MCB's of suitable rating to each capacitor. (Each capacitor bank equiped with discharge register) and 7% Detuned harmonic filter reactor. (v) High performance micro processor base 3 phase APFC relay 12 stage with auto/manual option. (vi) Inbuilt 3 phase power analyzer, Amp Meter, Volt Meter and PF Meter (Each have 01 No). (vii) Capacitor duty contactor with high thermal current carrying capacity and early make contacts to reduce inrush current for enhancing life of capacitor. (viii) Induced air system provided with axial flow fan/centrifugal fan. (ix) Bottom cable entry system available with front glass for viewing controller and annaliser from front. (x) MCB for line protection (xi) Current Transformer of suitable capacity, measuring class accuracy 0.5 to 1.0 Note:- 1.Anything missed out above but technically required for efficient working of APFC panel board is deemed to be included in quoted rates.
Disconnecting existing HT/LT cable from Transformer 1000 KVA capacity earthing strip from body and neutral of transformer lifting complete at installed site after tying with MS chain/hooks/U clamp etc and loading on a hired truck by employing extendable boom type crane and transporting to proposed site carefully and again unloading from hired truck for placing at desired place and connection HT & LT Cable,earthing etc at site complete all as specified and as directed including testing after installation.
Supply, installed, testing and commissioning of outdoor type automatic power factor correction LT capacitor bank panel board , duly powder coated RAL 7035, 450 KVAR 8 stages (2x25 + 4 x 50 + 2 x 100) for 3 phase, 415 V & 50 Hz System having following accessories including controlled wiring with HR/FRLS copper wire and suitable foundation / plateform work complete all as specified and directed:- (i) Compact modular bolted desigened, removable side and back panel with option of top and bottom cable entry. (ii) Capacitor installed in removable assemblies for ease of operation and maintenance. (iii) Suitable capacity of MCCB as Incomming of APFC Panel with high electrolyte grade Bus Bar of suitable rating, (iv) MDXL/LTXL capacitor of 25 KVAR-02 Nos, 50 KVAR-04 Nos, 100 KVAR-02 Nos with heavy duty capacitor duty contactor with coil voltage 230 V, 50 Hz and branch protection MCCB's/ MCB's of suitable rating to each capacitor. (Each capacitor bank equiped with discharge register) and 7% Detuned harmonic filter reactor. (v) High performance micro processor based 3 phase APFC relay 12 stage with auto/manual option. (vi) Inbuilt 3 phase power analyzer, Amp Meter, Volt Meter and PF Meter (Each have 01 No). (vii) Capacitor duty contactor with high thermal current carrying capacity and early make contacts to reduce inrush current for enhancing life of capacitor. (viii) Induced air system provided with axial flow fan/centrifugal fan. (ix) Bottom cable entry system available with front glass for viewing controller and annaliser from front. (x) MCB for line protection (xi) Current Transformer of suitable capacity, measuring class accuracy 0.5 to 1.0 Note:- 1. Anything missed out above but technically required for efficient working of APFCPanel Board is deemed to be included in quoted rates.
Excavation in post hole not exceeding 1.5 Mtr wide & upto 2 Mtr deep for pole foundation & getting out in soft loose soil and disposal of surplus soil to a distance n.exc 50 metres and return fill.
S&F for Mild steel angle iron fencing post and sturts in fencing incl necessary cutting drilling welding etc and bending to swan neck shape as required and drilling holes notching for wives etc conforming to Fe-290 Gde E-165 comlpete all as specified.
Supply only chain link fencing of mesh size 60mmx60mm with weight not less than 1.9 Kg/Sqm (actual weight to be determined through BOO during execution) complete all as specified & directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etcincluding provision of binding wire and fixing to angle iron fencing posts complete all as specified & directed.
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified.
Mild steel work conforming to Fe-290 (Gde E-165) as in fillets for fencing post including cutting top to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc complete all as specified & directed.
S&F mild steel screw bolts(machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n. exc 10 cm long and dia of shank 5 to 10 mm complete all as specified and directed.
M & L framed work as in door or gates of angle Iron or other sections with gusset plates rails, braces, etc. cut to size, bending Cold or Hot, drilling holes for bolts, in any shape or size as indicated or directed including, drilled for fixing of steel sheeting or other coverings, doors, etc. (exclusive of steel sheeting) and hanging, fixing also fastening, confirming to grade Fe-290 Gde E-165, complete all as specified and as directed.
M&L for preparation of newly steel and iron surface of any description width or girth exc 10 cm and applying two coats of synthetic enamel paint over a coat of Red Oxide primer complete all as specified and directed.
M&L for preparation of newly steel and iron surface of any description width or girth not exc. 10 cm and applying two coats of synthetic enamel paint over a coat of Red Oxide primer complete all as specified and directed.
M & L for plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for brick work with old size sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for hardcore broken stone boulder of guage not exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick watered and rammed to true surface complete all as specified and directed.
M&L for 150mm thick cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in hardstanding laid in bays,finished surface even and smooth without using extra cement complete all as specified and directed.
M&L rendering 15 mm thick in cm 1:4 on unfair faces of brick work or concrete surfaces finishing surfaces even and smooth without using extra cement , complete all as specified and as directed.
PURBANCHAL BUILDERS
MONA GENERATOR SEVICES PVT. LTD.
INDO CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .