Executive Engineer, Electric (R&B) Division, Rajkot
Replacing Old & u/s Transformer and Arm.Al Cable in HT Sub Station at Jilla Seva Sadan - 2 Rajkot .
327063
05 of 2026-27
Open
Electrical Works
Works
Rajkot
8 documents required · 8 mandatory
₹900
Executive Engineer, Electric (R&B) Division, Rajkot.
₹18,700
23 Jul 2026
23 Jul 2026
23 Jul 2026
6 Aug 2026
23 Jul 2026
Name of work: Replacing Old & u/s Transformer and Arm.Al Cable in HT Sub Station at Jilla Seva Sadan - 2 Rajkot
Item Quantities estimated Item of work Tendered Total amount
Item Quantities estimated Item of work Tendered Total amount
No. but may be more or Rate according to
Qty. Unit estiamted
Replacing Old & u/s by Providing, erecting, testing &
commissioning approved make oil immersed ONAN cooled,
double wound, core type indoor / outdoor copper wound 11kV/
433V step down transformer of following capacities operating
on 3 phase, 50 Hz 4 wire & neutral earthed system
continuously rated for a full temperature rise in oil not
exceeding 45 Deg.C.at maximum ambient temp. of 50 Deg. C.
complete with necessary radiator first filling of new
1 transformer oil & standard fitting as below complying with IS
1180( Part 1 ):2014 standards with energy efficiency level
Off load tap changing range steps +2.5% to -5% on H.V for
variation should be provided. The H.V. shall be connected
Delta & Secondary with star connection. The transformer
should have cable-end boxes on H.T. side suitable for up to
core 150 sq.mm. XLPE cable & on L.T. side suitable for bus
duct or cables as per requirement complete with test
certificates from manufacturers
1. Oil conservator with filling Hole & Cap - One No.
Thermometer pocket with 6" dial type thermometer switch
alarm & trip contacts- Two nos. 3. Silica-gel breather
with charge- One No.4. Plain oil level gauge - One No
Drain / Sampling / Filter valve- One No. 6. Top Filter Valve -
One No.7. Explosion vent with Diaphragm - One No.
Rating & Diagram plate - One No. 9. Additional neutral
bushing for earthing - One No. 10. Bi directional Roller -
Four Nos. 11. Earthing terminals - Two Nos. 12. Lifting lugs -
Two Nos. 13. Air release plug. - One No. 14. Double float
buchholz relay with Alarm and trip contacts. 15. Control
cable as required from Transformer to VCB Panel is to be
provided with necessary connection to VCB relays for
protection.as per IS 1180 level-1 (d) 800 KVA
Max. allowable loses as per IS 1180 level-1 at the time of
Providing and erecting ISI Marked 3 core 95 Sq.mm XLPE
insulated 11 kV armoured cable Aluminium conductor IS-
7098 to be laid on wall with clamps or in provided cable trench
/ pipe approved manner as directed.
Providing and erecting cable end termination kit, heat
shrinkable Push on type Densons/ Raychem/ Elastimold make
suitable for 11 kV XLPE cable 3core 95 & 120 Sq.mm (B)
Replacing Old & u/s by Providing and erecting FRLS-
XLPE(IS:7098)(I)-88 ISI armoured cable multistrand
4 20 Mtr Aluminium conductor for 1.1 kV. to be laid on wall with 1689.73
necessary clamps or in existing trench / pipe of following size
of cables (J) 3 1/2 core 300 Sq.mm ( 150 Sq. mm 1/2 core)
Providing and, fixing heavy duty flange type brass double
compression type cable gland with rubber ring for PVC
5 4.0 Mtr insulated armoured cable complete with out going tails, 280.78
insulating tape etc for following size of cables. (I) 3 & 1/2
core 300 Sq. mm
Item Quantities estimated Item of work Tendered Total amount
Item Quantities estimated Item of work Tendered Total amount
No. but may be more or Rate according to
Qty. Unit estiamted
Solder less crimping type Aluminium lugs conforming to IS
suitable for cable of following size evenly crimped with high
6 12 Ea. pressure tool & connected to switchgear terminals with 98.98
brass/cadmium plated nut bolts in an approved manner. (K)
Supplying & erecting earth pit of minimum bore dia.150mm
size approved make Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of corrosion free hot
dipped G.I.Pipes having Outer pipe dia of 50mm having 80-
200 Micron galvanising, Inner pipe dia of 25 mm having 200-
250 Micron galvanising, connection terminal dia of 12mm with
constant ohmic value surrounded by highly conductive
compound with high charge dissipation suitable for following
type of applications with chamber and heavy duty cover.
(A)(approved make OEM has to submit test certificate
including value of earth resistance of installation duly stamped
and signed by agency and officer Incharge has to ensure the
value of earthing resistane mentioned in test Certificate) &
having back filling compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC
62561-2017, Voltage drop:- < 1 volt at no load & dry form,
Sulphar content:- <2%(C) Back fill Compound :- Earthing
compound should be capable to retain moisture for long time
Necessary test report must be submitted by Agency.
(c) For Electrical Installation covering Transformer Neutrals,
Lightning arrester Earthing, A.C.Plant & Sensitive Computer
System(like Automation, SCADA) i.e independent Earthing in
Length of Pipe : 3.00 mtrs
Back filling Compound :2 nos Bags of 25 Kg.
Note:- The Credit of dismentalled materials for Rs.151407.00 shall be recovered from the First R.A. bill payable to the
contrator and there after the dismentalled materials shall be the property of the contractor.
I/We am/are willing to carry out the work at__________________% above/below (in
figures)_____________________________________percent Above / below (in words) the estimated rates mentioned above
amount of my\our tender works out as under :-
Estimated amount put to Tender Rs. _________
Deduct________% below Rs. _________
Net Amount Rs. _________
Estimated amount put to Tender Rs. _________
Net Amount Rs. _________
A I/We hereby declare that I/we have visited the site and fully acquainted my self / our selves with the local
situation regarding material,labour and other factors pertaining to the work before submitting this tender.
B I/We hereby declare that I/we carefully studied the conditions of contract, detailed technical specifications
and other tender documents of this work and agree to execute the same accordingly.
Item Quantities estimated Item of work Tendered Total amount
Item Quantities estimated Item of work Tendered Total amount
No. but may be more or Rate according to
Qty. Unit estiamted
C Any Excess in Tender Item/Extra Item if Needs to be Execute. Contractors has to carry out work on the
instruction of Competant Authority on Tender Submitted rate,No Excuse will be Accepted.Hence Contractor
are Requested to quote the rate considering this condition.
D Contractor are requested to quote the Tender by considering that payment will be made after availibility of
grant.Contractor has to start the work immediately after issue of Work Order and as per instruction of
E Engineer-in-Charge
"This irrespective
estimate has been preparedofonavailibility
the new SOR of grant.
wich is exclusive of GST hence GST additional will be
paid to the agency as per existing guidelines."
(Signature of the Contractor)
Note 1 Please strike out whichever is not applicable.
2 In the case of tendered amount being quoted incorrectly the quoted pered percentage Below/Above will be
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
ONLINE_NOTICE(R-2)(dn) RJT.pdf
SCH-B Bahumali Bhavan New TC.pdf
DM (5).pdf
MAKE FOR ELECTRICAL ITEM (3).pdf
SPECIAL CONDITION (4) Bahumali Bhavan New TC.pdf
SBD.docx
DOCX
Contractor_Registration_Paripatra__1_.pdf
EMD GR.pdf
GR for Extra Item.pdf
GR for single Tender.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].