Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Rejected-Technical MARINE CORPORATION OF INDIA PROP ANAND SHIP CARE INSTITUTE PVT LTD 25 9 14 MARINE TOWERS RAJAVARI VEEDHI VISAKHAPATNAM | Rejected-Technical Reduced scope not accepted by the firm. |
Tender Value
Refer Docs
Closing Date
21 Mar 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DGM(SRM)
CSL COCHIN
AS PER TENDER
2022_CSL_108921_1
SR4/FRP/MV RAJHANS/CANSRU
Open Tender
Miscellaneous Services
Turn-key
10 days
CANSRU_PORT BLAIR
AS PER TENDER DOCUMENT
2 documents required · 2 mandatory
₹0
Exempted
25 Mar 2022
9 Mar 2022
22 Mar 2022
9 Mar 2022
21 Mar 2022
9 Mar 2022
120 days
Anchor launching frame base damaged badly. Deck in the periphery to be strengthened. Ensure strengthening with water tight integrity.(With Materials.) Surface of deck need to be repair with materials and non-skid gratings. Base of Anchor should be reviewed and need to provide stiffening or replacement of deck material if needed.Repair procedures should be submitted to CSL.
Main Deck base at Foxcle needs to be strengthened. Inside transverse and longitudinal members needs to be checked and add superior hardwood (resistant to termite).(With Materials.).Frames should be hat frames below the deck(2 longitudinal and minimum 4 transverse members).
Fresh water tap console at Aft (Port side) damaged, to be repaired. Size of the console 30 x 25cm, material Fibre. Ensure strengthening with water tight integrity.(With Materials).The scope of work of console will be repairing the damage area or refabrication of console with FRP Material which can be decided after the inspection on the boat.Water integrity should be checked by standard testing procedures.
Chain locker hatch cover’s S.S hinge damaged.Need to Install new SS 316 Hinge and Test need to be conducted as per the ISO 12216:2020(EN) Small craft Windows, portlights, hatches, deadlights and doors Strength and watertightness requirements. For flush type hatches.(With Materials)
Deep cracks noticed on 06 numbers freeing ports at forecastle deck, to be repaired. With Materials.CSL recommend two ways to approach the repair First Case: Provide a SS316 frame around the freeing ports after rectifying the fibre crack to avoid the issue in future. This frames will be fastened using approved and qualified marine grade bonding materials and methods. Second case: To repair fibre work and finish with gelcoat without the SS frame.
AFT station fire hydrant FRP door damaged to be re-fabricate.Existing locks and hinges should be replaced by new SS 316 Marine grade locks and hinges.Door size - 270x440mm.
Floor of Dining room and sitting accommodation at Main Deck found surging at various places, needs to be strengthened with renewal of existing frame base with superior hardwood (resistant to termite)/laminations and need to replace the damaged floor material with exactly new material with same colour, texture and dimension as existing materials onboard.Remove all defected areas floors and inspect that if any sagging on the main deck structure if yes deck area need to repair.
E/Room Fibre Door damage at places. Wooden /plywood structure of the door also damaged. Door alignment also needs to be carried out to attain water tight integrity. Rubber packings to be renewed. Size of the Door: 1440 mm x 660 mm x average thickness 60 mm. With Materials. 1: Remove the door. 2:Check the alignment of Opening. 3:Do corrections if needed and repair the flanges if cracks found, 4:Check the door also for same. 5:Semi circular type rubber beading of size 25x30mm.to be fixed with standard procedures and Marine grade fastening materials. 6:Hose test and chalk test need to be conducted and cleared.
Stanchion rail pockets on poop deck to be repaired using superior grade approved caulking materials and Teak wood base to be coated/strengthened. With Materials.Sika 290DC and primer 290DC or material with equivalent spec needs to be used for teak decking. 1:Replacement of damage teak materials. 2:Make sure proper drain system is given in the pockets.
Transverse beams and forward panting agents, supporting the galley deck got badly damaged by the termite infection leading to shrinking of the deck, to be repaired/strengthened with required material as per present set up and ensure termite freeness.Remove all the existing damage Stiffeners.Prepare the surface for adding new stiffener (90x50) by bonding materials.After lamination Sound insulation need to be provided in Bow thruster compartment (25 mm Sound insulation material or Equivalent). Ensure deck is leveled prior to installation of frames.
Two HSD tanks, to be cleaned. Manhole Doors to be refit with renewal of Gaskets and ensure pressure testing (With Materials).Tanks should be cleaned properly using adequate materials. Total 6 Nos of Manholes
Fresh water Tank Electrical sensor arrangements assembly on the manhole cover damaged, leading to loss of water. Water tight integrity needs to be corrected. Opening and closing of the manhole doors with renewal of the Gaskets, Seals, Fasteners as required.With Materials.After repair test need to conduct, can be either Hydraulic pressure test or APT. As per requirements from class.
The base of main mast damaged badly due to termite infection, to be corrected after inspecting the existing damage mast base. After dismantling the mast from the upper deck ,remove the damaged by cutting.Insert SS 316 backing plate on the base for the installation of MAST.
The base of Fly bridge Deck damaged badly due to termite infection, The base can be re-fabricated With Materials. This job can be accompanied with the DL NO: 41 by including following task. 1:Remove the lower and above deck damage area after examining the defect. 2:Prepare the new deck with the Mast base from Outside. 3:Fix the deck with bolt and nut and laminate on top of it to make sure the water integrity. 4:Below deck should be stiffened using 50x50 hat stiffeners.
FRP Repairs (with materials and labour) FRP repairs to be carried out on underwater hull with 03 layers of resin mat and one coat of gel coating. All materials used should preferably be Class Approved/best quality materials and of international standards. Note:Prior to usage the material should get inspected by the visiting Surveyor(s) and obtain clearance.The Qty. mentioned is just an estimation. The amount admissible shall be subject to final measurement of the area/actual quantum of work carried out. If any deviation from the qty. mentioned herein, payment shall be admitted on pro rata basis.
Quote shall include service and material cost but not the cost of Paint.
The entire underwater hull surface shall be washed with alkaline emulsifiable detergent. Agitate the surface with non-metallic brushes or non-metallic woven fibre cleaning pads to activate the detergent and before it dries wash the treated area by low pressure water cleaning LPWC method to ISO 8501-4 WA1 using fresh water in order to remove contamination. The damaged and surrounding intact coating shall be hand or machine abraded with 150-180 grade silicon carbide or aluminium oxide wet or dry sanding abrasives or bonded fibre machine or hand abrasive pads to remove all under bound and damaged coating to reveal the substrate. Ensure remaining intact coating has all leading edges feathered to ensure smooth transition from the intact coating to the substrate. All surfaces shall be prepared to remove all polish and to impart a surface profile for coating adhesion to the surface. Note: 1. The entire painting job shall be carried out under the supervision of the Paint Inspector of the respective Paint Manufacturer which shall be arranged by the vendor at their own cost. The entire job shall also be witnessed by the Class Surveyor as well as MMD Surveyor from time to time. The cost towards visit of the Surveyor(s) shall be borne by the Department. 2. The paint scheme should be guaranteed for 05 years (60 months) under normal trading conditions in an average sea water temperature. Vessel cruising speed 19-knots (Minimum). Hence, the paints applied should sustain. 3. Necessary certificates viz. TBT certificate of paints, guarantee certificate and purchase invoice to be submitted at the time of inspection on completion of the work. 4. Firm while quoting should furnish detailed paint scheme intended to be applied giving details of type of coat/DFT/WFT etc. 5. The amount admissible shall be subject to final measurement of the area/actual quantum of work carried out. If any deviation from the qty. mentioned herein, payment shall be admitted on pro rata basis.
VIP Cabin Stbd false ceiling and Deck due to termite infection to be strengthen and reinforced to ensure termite freeness. With Materials. 1:Damage woods to be replaced with new woods of same texture and high quality. 2:Proper coating should provide on the woods to avoid future defects. 3: All technical documents of wood should be submitted prior to the work Wooden Door frames damaged. Remove all the existing damage Stiffeners.Prepare the surface for adding new stiffener (90x50) by bonding materialsAfter lamination. Ensure deck is leveled prior to instalation of frames.
VIP Cabin Port Deck damaged due to termite infection to be strengthened and reinforced to ensure termite freeness. With Materials. Remove all the existing damage Stiffeners.Prepare the surface for adding new stiffener (90x50) by bonding materialsAfter lamination. Ensure deck is leveled prior to instalation of frames. Wooden Door frames damaged
Flame arrester of HSD tank and 01 No. mesh of Fresh Water Tank to be renewed., WIN TAB need to be reviewed and replace with certified material if needed.
All FRP coating to be carried out with 3 layers of resin mat and 01 coat of gel coating on the areas involving repairs to the structure and damaged FRP coatings in respect of works mentioned above. Note a) The finish should match exactly with the existing colour and texture. b) On completion of work physical measurements shall be done for ascertaining actual quantum of work carried out and payment shall be made on pro-rata basis. c) The Qty. mentioned is approximate. Actual quantum shall be ascertained on final measurement. d) All FRP materials used should preferably be Class Approved/best quality materials and of international standards. Prior to usage the material should be got inspected by the visiting Surveyor(s) and obtain clearance.
COST OF PAINT ONLY (Optional item). This cost shall not be taken for price comparison Note: 1. The entire painting job shall be carried out under the supervision of the Paint Inspector of the respective Paint Manufacturer which shall be arranged by the vendor at their own cost. The entire job shall also be witnessed by the Class Surveyor as well as MMD Surveyor from time to time. The cost towards visit of the Surveyor(s) shall be borne by the Department. 2. The paint scheme should be guaranteed for 05 years (60 months) under normal trading conditions in an average sea water temperature. Vessel cruising speed 19-knots (Minimum). Hence, the paints applied should sustain. 3. Necessary certificates viz. TBT certificate of paints, guarantee certificate and purchase invoice to be submitted at the time of inspection on completion of the work. 4. Firm while quoting should furnish detailed paint scheme intended to be applied giving details of type of coat/DFT/WFT etc. 5. The amount admissible shall be subject to final measurement of the area/actual quantum of work carried out. If any deviation from the qty. mentioned herein, payment shall be admitted on pro rata basis. Paint OEM recommended by the Owner Jotun,Akzo Nobel and Sigma. The entire painting job shall be carried out under the supervision of the Paint Inspector of the respective Paint Manufacturer. Paint delivery location: Cochin Shipyard Ltd, CSL-AN Ship Repair Unit (CANSRU), Marine Dockyard, Marine Jetty Post Office, Port Blair, Andaman & Nicobar Islands, PIN: 744101 PAINT SCHEME FOR THE RAJHANS UNDERWATER AREA – 150 SQM Apply paint scheme on underwater area should similar to following: 1: One coat Epoxy anti-corrosive primer DFT 100 micron 2: One coat Epoxy anti-corrosive primer DFT 100 micron 3: One coat tie coat for silicon antifouling DFT 125 micron 4: One coat Silicon Antifouling DFT 100 Micron 5: One coat Silicon Antifouling DFT 100 Micron BOOT-TOP AREA – 10 SQM Apply paint scheme on Boot top area should similar to following: 1: One coat Epoxy anti-corrosive primer DFT 100 micron 2: One coat Epoxy anti-corrosive primer DFT 100 micron 3: One coat tie coat for silicon antifouling DFT 125 micron 4: One coat Silicon Antifouling DFT 100 Micron 5: One coat Silicon Antifouling DFT 100 Micron
Note*** Bidders have to strictly follow above price bid format while quoting. Bidders are requested to carefully go through all the scope before quoting. Optional item shall not be taken for price comparison purpose. GST Amount shall not be taken for price comparison purpose.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .