Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.5 LAccepted-AOC AMARPUR GOMATI TRIPURA | AMARPUR | GOMATI | TRIPURA | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹44.8 L+₹1.3 L (3.04%)Rejected-Finance DHALESWAR JAIL ASHRAM ROAD AGARTALA TRIPURA W | DHALAI | TRIPURA | 799204 | L2 | Rejected-Finance Higher bidder |
Tender Value
₹45.8 L
EMD Value
₹91,554
Closing Date
15 Jun 2023, 5:00 pmClosed
DGM, ED-Amarpur
O/o the DGM, ED-Amarpur
Extension of HT /LT line including 17X63 KVA substation for providing 3(three) phase Service Connection to 17(Seventeen) nos newly Shunk DTW scheme of Water Resource Department
2023_POWER_39053_1
DGM/ED-AMP/2023-24/03 03.06.2023
Open Tender
Electrical Works
Turn-key
90 days
ED-Amarpur
As per NIT
3 documents required · 3 mandatory
₹10,000
Yes
₹91,554
Yes
O/o the DGM, ED-Amarpur
17 Jan 2024
5 Jun 2023
16 Jun 2023
5 Jun 2023
15 Jun 2023
9 Jun 2023
5 Jun 2023 - 7 Jun 2023
8 Jun 2023
Amount
Schedule-A Supply
9 mtr. Long PCC Pole
8 mtr. Long PCC Pole
GI Stay Set HT 20 sqmm
GI Stay Set LT 16 sqmm
Stay insulator for H.T (Porcelin)
Stay insulator for L.T (Porcelin)
Stay wire 7/2.50 sqmm
Supply of fabricated Stay clamp pair of assorted size of MS flat (50x6mm) with double coat of red oxide primer coating & 2 nos ISI marked machine made nut bolts of size 16 x 75 mm & washer for erection of stay set
MS Channel (100 x 100x50x 6 mm )
MSl Channel ( 70 x 40x40x 6 mm )
MS Angle ( 65x 65x 6 mm)
11 KV G.O.S (three phase)(Polymeric type) unit set of three nos
11 KV D O F (three phase)(Polymeric type) unit set of three nos i/c
9 KV , 5 KA single pole metal oxide gapeless type LA
11 KV Polymer composite 45 KN Disc Insulator) along with necessary fittings
11 KV Disc fittings(6/1/2.59 & 6/1/3.35)
11 KV 320 mm CD Polymer composite PIN Insulator along with necessary fittings
ACSR (WEASEL ) 30 sq mm conductor
GI 8 SWG Gi wire
LT AB Cable 3phase (3x25+1x16+1x25 ) sqmm
LT Insulation Piercing Connectors (IPC) main 16-95 sqmm & tap 4 to 35 (50) sqmm
Eye hook(25 mm)
Cable end cap (25-35 mm/50mm)
Service line anchor clamp 18-50 mm
Cable Ties
Pole clamp (25-50mm)
Suspension clamp Assembly with straps & buckle (50 sq mm)
LT Dead End clamp Assembly with straps & buckle (25-35 mm)
Distribution box three phase (25 mm)
Nut & bolts 16X50 mm
Nut & bolts 16X75 mm
Nut & bolts 12X250 mm
Nut & bolts 12X90 mm
Nut & bolts 12X300 mm
11 KV Danger plate
LT Danger plate
Supply of fabricated M.S clamps of assorted size of MS flat (50x6mm) with double coat of red oxide primer coating & 2 nos ISI marked machine made nut bolts of size 16 x 75 mm & washer for erection of stay set
Rewireable porcelin Cut Out 100 amp
Rewireable porcelin Cut Out 200 amp
Alumunium Lux 35 sqmm
Bi-matallic Lux 70 sqmm
Bi-matallic Lux 95 sqmm
Bi-matallic Lux 120 sqmm
120 Sqmm PVC Cable
PVC 70 mm sq
35 Sqmm PVC Cable
16 Sqmm PVC Cable
10 Sqmm PVC Cable
Reel Insulator 16-25 sq mm
Providing Coil Earthing by * SWG GI Wire as per Specification
Supply of 60 Kg Salt and 55 Kg Charcoal (For 1 Pit).
Supply of 2.5 mtr. Long 40 mm dia G.I Pipe (Make: TATA JINDAL)
Erection
9 mtr. Long PCC Pole at any kind of soil upto a depth of 1/6th of pole height in/c excavation, refilling the pit with soil up to the ground level , ramming & making complete in all respect i/c hand cart carriage & manual carriage with necessary loading & unloading
8 mtr. Long PCC Pole at any kind of soil upto a depth of 1/6th of pole height in/c excavation, refilling the pit with soil up to the ground level , ramming & making complete in all respect i/c hand cart carriage & manual carriage with necessary loading & unloading
Erection of painted stay set complete direct in earth with 19 mm dia 1.8 mtr long painted stay rod ,anchor plate of size 300x300x8 mm ,thimble, turn buckle ,7/3.15 mm dia GI stranded wire & stain insulator insulator etc in/c supply of MS Clamp,Nut & Bolts etc asa reqd. & making complete in all respectas per direction of Eng -in - charge.`(GI Stay Set HT 20 sqmm)
Erection of painted stay set complete direct in earth with 19 mm dia 1.8 mtr long painted stay rod ,anchor plate of size 300x300x8 mm ,thimble, turn buckle ,7/3.15 mm dia GI stranded wire & stain insulator insulator etc in/c supply of MS Clamp,Nut & Bolts etc asa reqd. & making complete in all respectas per direction of Eng -in - charge.`(GI Stay Set LT 16 sqmm)
2.8 mtr long MS Channel (100 x 100x50x 6 mm ) for sub stn. etc
0.8 mtr long MS Channel (100 x 100x50x 6 mm ) for sub stn. etc
2.8 mtr long MS Channel ( 75 x 40x40x 6 mm )for sub stn. GO,DO fixing bkt. Etc
MS Channel ( 75 x 40x40x 6 mm ) 2.2 mtr long for single pole bottam cross arm
MS Channel ( 75 x 40x40x 6 mm ) 1.3 mtr long for single pole bottam cross arm
MS Channel ( 75 x 40x40x 6 mm ) 0.3 mtr long for single pole top cross arm
MS Angle ( 65x 65x 6 mm) 3.1 mtr long S/S Guarding cross arm
MS Angle ( 65x 65x 6 mm) 2.8 mtr long S/S Guarding cross arm
MS Angle ( 65x 65x 6 mm) 2.5 mtr long DP cross arm
MS Angle ( 65x 65x 6 mm) 2.2 mtr long DP cross arm
MS Angle ( 65x 65x 6 mm) 1.5 mtr long SP Guarding cross arm
11 KV G.O.S (three phase)(Polymeric type) unit set of three nos i/c necessary connection as complete as per T.S
11 KV D O F (three phase)(Polymeric type) unit set of three nos i/c necessary connection as complete as per T.S
9 KV , 5 KA single pole metal oxide gapeless type LA i/c necessary connection as complete as per T.S
11 KV Polymer composite 45 KN Disc Insulator) along with necessary fittings
11 KV 320 mm CD Polymer composite PIN Insulator along with necessary fittings
Laying & stringing of ACSR (WEASEL ) 30 sq mm conductor in/c hoisting & binding etc. complete as required
Laying & stringing of 8 SWG Gi wire in/c hoisting & binding etc. complete as required
Supply & Laying & stringing of LT AB Cable (3x35+1x16+1x25 ) in/c hoisting & binding etc. complete as required
Erection & fitting & fixing of LT Insulation Piercing Connectors (IPC) all sizes of 1.1 kv grade in/c connection from main cable to distribution box, Tee -Off line as per direction of Engineering In Charge
Erection & fitting & fixing of insulated Dead End enchoring clamp in/c pole clamp,Eye hook for cable messanger of 1.1 kv grade on PCC/ST pole with the help of pole brackets or steel straps & buckles as per direction of Engineering In Charge
Erection & fitting & fixing of insulated Suspension clamp in/c pole clamp,Eye hook for cable messanger of 1.1 kv grade on PCC/ST pole with the help of pole brackets or steel straps & buckles as per direction of Engineering In Charge
Erection & fitting - fixing of service main 3 phase distribution box of 1.1 kv grade on PCC/ST pole with the help of pole brackets or steel straps & buckles as per direction of Engineering In Charge
Insttalation/ Positioning of 11/0.430 KV , 3 phase 63 KVA distribution transformer on pole with necessary connections & fitting & fixing of all allied assessories , components as redq. For making complete in all respect for energizing
Fitting & fixing of 11 KV Danger plate
Fitting & fixing of LT Danger plate
Fabrication of Steel Materials
Providing Sub-Station fencing by 75x25 mesh of size 2.5x3.5 mtr, and height of 1.5 mtr, as per Engineering requirement by ms angle (50x50x6mm) of height 2.0 mtr Horizontal Bar 6x3.5 mtr and x 2.5 mtr and vertical Bar 10x1.5 mtr of ms flat (35x6mm) and singlepart of MS Grill door of size L-1.5/B-1.2 mtr with locking arrangement including necessary grouding and painting by Aluminium paint over Red oxide priming of approved quality as reqd. as per TS including supply of all materials.
Maintaining adequate clearance from overhead line conductors by trimming of tree branches for way leaves
Providing 3(Three) phase service connection to barrak with laying PVC cable from nearby electrical pole to premices upto 35mtr. In length suported by G.I wire, reel insulator including fitting fixing of energy meter as required.
Earthing with GI pipe 2.5 mtr Long and 40 mm dia, inc. excavation, refilling with alternate layer of salt & charcoal as per drawing (excluding supply of GI wire, nuts & bolts, etc. as required)
Erection of protective guarding / cross lacing for 415/240 volt line by GI wire 98/10 SWG as per technical specificationacross road/river/telecom line etc.in horizontal/verticle formation complete with spool/Reel insulator
ADHIR DEBNATH
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .