| 1 | L1₹10.4 LAccepted-AOC | ₹10.4 L Quoted ₹10.8 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹12.7 L+₹1.9 L (17.9%)Rejected-Finance | ₹12.7 L+₹1.9 L (17.9%) | L2 | Rejected-Finance Second Lowest |
| 3 | L3₹12.8 L+₹2.1 L (19.3%)Rejected-Finance | ₹12.8 L+₹2.1 L (19.3%) | L3 | Rejected-Finance Third Lowest |
| 4 | L4₹17.7 L+₹7.0 L (64.7%)Rejected-Finance | ₹17.7 L+₹7.0 L (64.7%) | L4 | Rejected-Finance Fourth Lowest |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
21 Sept 2023, 6:00 pmClosed
Major S N Gaikwad
Holta Cantt Palampur
REPAIR MAINTENANCE OF INTERNAL WIRING MCBs DBs SUB MAIN WIRING AND ELECTRICAL FITTINGS IN OFFRS JCOs OR MESS AT PALAMPUR MIL STN
2023_MES_615277_1
GEP-50/2023-24
Open Tender
Civil Works
Item Rate
180 days
Palampur Mil Stn
As per tender documents
8 documents required · 8 mandatory
₹500
GE Palampur
₹40,000
28 Nov 2023
23 Aug 2023
23 Sept 2023
23 Aug 2023
21 Sept 2023
7 Sept 2023
Amount
Taking down old unserviceable copper/ aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden/iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down un-serviceable DB of any size and capacity including MCB etc, and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed.
Taking down un-serviceable sub main wiring of any type and any size from wall, ceiling etc. complete all as specified and directed.
M&L for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm PVC (FRLS-H) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLSH) insulated unsheathed multi stranded copper conductor cable draw in & incl PVC surface casing 'N' capping double lock type to be fixed with the help of rawal plugs & screws incl all fittings such as Tee, connector pieces, L-junction etc on joints including polycarbonate/modular GI sheet metal flush boxes of anyway (as per site requirement) and modular white cover plate with frame for mounting switches, sockets, regulators etc for fixing one light/fan/bell point controlled by one switch and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed. Notes : (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof/celing PVC casing 'N' capping shall be provided on surface with proper fixing clamps all as directed by Engr-in-Charge.
All as per the description of serial item No 04 here-in-before but one 5 pin socket outlet, 5 amps on the same board complete all as specified and directed.
All as per the description of serial item No 04 here-in-before but one 5 pin socket outlet, 5 amps, independent complete all as specified and directed.
All as per the description of serial item No 04 here-in-before but for one 5 pin socket outlet 15 Amps on Independent board with cables 2.5 sqmm size complete all as specified and directed. Note:- Power circuit shall be done in separate circuit.
S&F in replacement ceiling rose, 3 terminal surface type complete all as specified and directed.
S&F in replacement angle lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F in replacement ding dong bell musical type AC 230 volt single pole complete all as specified and directed.
M&L for point wiring for one light/fan/call bell point controlled by one 5/6 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLSH, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLSH, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid conduit medium grade, ISI marked including pressed steel with existing colour terminated boxes of Modular GI sheet Metal flush Boxes of any way i.e. (1 to 8 way as per site requirement) for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Note:- (a) Wiring shall be done by using proper colour coding (b) Earth wire shall be of green colour (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engr-in-Charge.
All as per the description of serial item No 11 here-in-before but 5/6 Amp socket outlet on same board complete all as specified and directed.
All as per the description of serial item No 11 here-in-before but socket outlet 5/6 Amps independent board complete all as specified and directed.
All as per the description of serial item No 11 here-in-before but for one 6 pin socket outlet 15/16 Amps on independent board with cables 2.5 sqmm size complete all as specified and directed.
S&F in replacement modular switch 1 way 6 A,1 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement modular switch 1 way 16 A, 1 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement socket, 6A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement socket 6A/16A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement modular bell push 6A 1 module complete all as specified and directed.
S&F in replacement modular fan step regulator, 120W 1 module, 240 volts ISI marked complete all as specified and directed.
S&F single pole and neutral enclosure with 1 two pin and earth plug and a socket complete with one single pole MCB, 20 Amp, 240 volts ISI marked complete all as specified and directed.
M&L wiring for one light point controlled by two 2 way switches, with 1.5 Sqmm single core multistranded copper conductor FRLSH, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistrand FRLSH, PVC insulated (unsheathed) drawn into and including concealed PVC rigid conduit medium grade ISI marked modular GI sheet metal flush boxes of any way (as per site requirement) and modular white cover plate with frame for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following:- (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall of green colour (c) On RCC roof/ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
S&F modular switch 2 way 6 A,1 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement LED complete fitting including batten LED polycarbonate 1 x 20 watt tuberod, appx 4 feet long, environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and specifications complete all as specified and directed. Make:- Crompton/Havells/Bajaj or equivalent make as approved by GE.
Supply & fixing energy efficient LED light of 10/12 Watt of length - 02 Feet long having minimum 1100-1300 Lumen output, wide voltage protection range 140-270 Volt AC housed in extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make:- Cat part No: -LUMILINEPLUSSBS 10WLED865SPCSS of make Havells 'or' BN 021 LED10S- 6500 PSU GR S1 of make Philips 'or' LDL-10-WW of make Crompton or its equivalent as approved by GE.
S&F in replacement energy efficient LED light of 5/7 watt-01 feet long having minimum 1100-1300 lumen output, wide voltage protection range 140-270 volt AC housed in extruded aluminium housing (enhances safety) with high quality polycarbonate diffuser including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make:- Crompton/Havells/Bajaj or equivalent make as approved by GE.
Taking down old burnt out bulk head fitting any type and supply and fix LED bulk head 10W with pressure plastic housing with clear prismatic diffuser, high efficient LEDs IP66 complete all as specified and directed. Make Crompton/Havells/Bajaj
S&F in replacement Sheet metal enclousers, TPN distribution board 4 way, double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
M&L distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
M&L distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
M&L distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 6 way 240 volts double door complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
M&L distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
S&F in replacement 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S&F in replacement SPN 40 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S&F in replacement SPN 63 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S&F in replacement 415V 10KA 'C' curve TPN 63 Amp miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
S&F in replacement 415V 10KA 'C' curve TPN 100 Amp miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
M&L in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sq mm for phase and neutral and one run of 4.0 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note:- Wiring shall be done in proper colour coding.
M&L in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sq mm for phase and neutral and one run of 6.0 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note:- Wiring shall be done in proper colour coding.
M&L in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 10 Sq mm for phase and neutral and one run of 10.0 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note:- Wiring shall be done in proper colour coding.
S&F in replacement LED bulb 9 watt 230 volts AC outdoor type complete all as specified and directed.
S&F in replacement LED bulb 7 watt 230 volts AC outdoor type complete all as specified and directed.
S&F in replacement post top lantern LED type 20 watt 230 votls AC outdoor type with decorative post top for 360 degree indirecddt light IP65 protection with impact and corrosion resistent complete with driver and lamp complete all as specified and directed.
S&F LED flood light fitting 30 watt 230V outdoor type with high pressure die cast aluminium housing and heat resistant complete with dirver lamp bracket IP65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
S&F LED flood light fitting 50 watt 230V outdoor type with high pressure die cast aluminium housing and heat resistant complete with dirver lamp bracket IP65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
S&F in replacement LED round bollard light type 7 watt 230 volt AC outdoor type for 360 degree indirect light IP65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
S&F in replacement LED ground burial light type 12 watt 230 volts AC outdoor type with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
S&F in replacement LED spike light type 6 watt 230 volts AC outdoor type with impact and corrosion resistant complete all as specified and directed.
S&F in replacement LED spike light type 9 watt 230 volts AC outdoor type with impact and corrosion resistant complete all as specified and directed.
S&F in replacement recess mounted slim LED luminaire with drop down diffuser light 36W 230 volts AC corrosion resistant complete all as specified and directed.
S&F in replacement high efficiency square LED downlighter 14W 230 volts AC corrosion resistant complete all as specified and directed.
S&F in replacement high efficiency panel frameles round LED downlighter 24 watt of any size as per requirement at site 230 volts AC corrosion resistant complete all as specified and directed.
S&F in replacement MCCB 63 amp, 415V, 50 Hz AC made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity complete all as specified and directed.
S&F in replacement MCCB 100 amp, 415V, 50 Hz AC made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity complete all as specified and directed.
S&F in replacement MCCB 125 amp, 415V, 50 Hz AC made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity complete all as specified and directed.
S&F in replacement MCCB 160 amp, 415V, 50 Hz AC made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity complete all as specified and directed.
M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connecting to GI earth wire of size 4mm size by means of bolts, nuts, check nuts and protected by provision of GI medium grade pipe of 15mm bore including provision of 40mm tk cover of RCC (1:2:4) reinforced with XPM (wt no less than 4Kg/sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made to shape, GI light grade 20mm dia pipe for watering of suitable length placed on tp edge of earth plate, common salt and charcoal filling, with fixing arrangement, funnel, wire mesh and excavation and earthwork in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m complete all as per plate No. 3 of SSR 2009 Part-I and connecting to earth test point all as specified and directed by Engineer-in-Charge and including testing on completion.
Note:-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B1, 80mm thick reinforcement with 8mm TOR steel @ 100 c/c in lieu of CI cover and the rate includes in the unit rate of item. (ii) Earth electrode shall be protected upto test point using necessary arrangement with suitable size GI pipe up to 7.50m and the rate includes in the unit rate of item. (iii) Earth pit chamber and RCC cover shall be painted with red paint over a primer coat and the rate includese in the unit rate of item. (iv) The earth chamber shall be constructed 5m away from the edge of the bldg pit and the cost of the same is deemed to be included in the rate for this item.
S&F in replacement switch piano flush button type 6 amps single pole one way complete all as specified and directed.
S&F in replacement socket outlet multipurpose 2/3 pin 6 amps flush button. complete all as specified and directed.
S&F in replacement switch piano flush button type 16 amps single pole one way. complete all as specified and directed.
S&F in replacement switch socket combination 6/16 A single pole one way complete all as specified and directed.
S&F in replacement socket outlet multipurpose 2 in 1, 6 and 16 Amps. complete all as specified and directed.
S&F in replacement stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and directed.
S&F in repairs single core flexible PVC cable 1.5 sqmm of standard copper conductor PVC insulated unsheathed cables of 1100 volts complete all as specified and directed.
S&F in repairs single core flexible PVC cable 2.5 sqmm of standard copper conductor PVC insulated unsheathed cables of 1100 volts complete all as specified and directed.
M&L twin core flexible PVC cable 1.5 Sqmm of strandard copper conductor PVC insulated unsheathed cable of 1100 volts complete all as specified and directed.
M&L twin core flexible PVC cable 2.5 Sqmm of strandard copper conductor PVC insulated unsheathed cable of 1100 volts complete all as specified and directed.
S&F in replacement SPN 40 to 63 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
M&L in replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
M&L in replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
M&L in replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
S&F in replacement surface mounting 9/12 watt LED mirror light fitting of 2 feet length complete all as specified and directed.
S&F in replacement PVC surface box 3 module with 5 amp switch and socket complete all as specified.
M&L in replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
S&F in replacement PVC surface box 3 module with 15 amp switch and socket complete all as specified.
S&F in replacement PVC LT insulation tape roll of size 25 mtr complete all as specified.
S&F in replacement PVC insulation empire tape roll of size 25 mtr complete all as specified.
S&F in replacement PVC casing caping of size 20mm, ISI mark complete all as specified.
S&F in replacement rigid non-metallic PVC conduit of size 20mm, ISI mark complete all as specified.
S&F in replacement Hylem sheet 3mm thick of size 9" x 11" including cutting of sheet for fixing swtich/socket complete all as specified and directed.
S&F in replacement Hylem sheet 3mm thick of size 8" x 5" including cutting of sheet for fixing swtich/socket complete all as specified and directed.
S&F in replacement Hylem sheet 3mm thick of size 5" x 5" including cutting of sheet for fixing swtich/socket complete all as specified and directed.
Disconnecting/taking down exhaust fan of any sweep removing and cleaning the dust properly, painting with same colour good quality synthetic enemelled paint after preparing surface for painting with existing colour shade oiling and greasing of bearing including refixing, rewinding if required and making thet connection and testing complete all as specified and directed.
Disconnecting/taking down ceiling fan of any sweep removing and cleaning the dust properly, painting with same colour good quality synthetic enamelled paint after preparing surface for painting and making the connectoin and testing complete all as specified and directed.
S&F exhaust fan ISI marked, heavy duty steel body complete with louvers shutter, AC single phase, 230V, 50 Hz, RPM 1200, copper winding of sweep 300mm complete with connection from ceiling rose to exhaust fan complete all as specified and directed. Note: Old unserviceable exhaust fan to be deposited in MES yard.
S&F exhaust fan ISI marked, heavy duty steel body complete with louvers shutter, AC single phase, 230V, 50 Hz, RPM 1200, copper winding of sweep 450mm complete with connection from ceiling rose to exhaust fan complete all as specified and directed. Note: Old unserviceable exhaust fan to be deposited in MES yard.
S&F exhaust fan ISI marked, made of sturdy engineering plastic complete with louvers shutter, AC single phase, 230V, 50 Hz, RPM 1200, copper winding of sweep 200mm complete with connection from ceiling rose to exhaust fan complete all as specified and directed. Note: Old unserviceable exhaust fan to be deposited in MES yard.
S&F 1200 mm sweep ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Make :- Orient Model 1200mm I-1TOME/ Crompton eSave 50/ Havells Fusion 50 or equivalent make as approved by GE. Note: Old unserviceable ceiling fan to be deposited in MES store yard.
M&L 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm dia suspension GI wire with stranded conductor 06 sqmm twin core cable flat or circular including taking down old unserviceable cable and stacking at site complete all as specified and directed.
M&L 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm dia suspension GI wire with stranded conductor 10 sqmm twin core cable flat or circular including taking down old unserviceable cable and stacking at site complete all as specified and directed.
M/S Gagan Khosla
M/s Sheetal Associates
M/S MALHI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .