Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical MATHABHANGA COOCH BEHAR | MATHABHANGA | COOCH BEHAR | WEST BENGAL | Admitted-Fee/PreQual/Technical |
| 5 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹3.3 L
EMD Value
₹6,698
Closing Date
9 Sept 2026, 12:30 pmClosed
EXECUTIVE ENGINEER PURULIA DIVISION PWD
EXECUTIVE ENGINEER PURULIA DIVISION PWD RANCHI ROAD POST DIST PURULIA
Repair and Rehabitationa to ceiling column and other ancilary work of Matri Mangal Building (PP Unit) at Sadar Campus of Deben Mahato Government Medical College and Hospital under Purulia Sub Division PWD of Purulia Division PWD during the year 26-27
2026_WBPWD_5021091_5
WBPWD/EE/PRLDN/NIET_9/26-27
Open Tender
CIVIL WORKS
Percentage
45 days
PURULIA
Please refer Tender documents.
4 documents required · 4 mandatory
₹6,698
Yes
11 Sept 2026
31 Aug 2026
11 Sept 2026
3 Sept 2026
9 Sept 2026
3 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge
25 mm average thickness | 168.2 | Sq.M. | 126.75 | ₹21,319.35 |
| 2 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.
Bars upto 12 mm diameter | 1,682 | Metre | 8.25 | ₹13,876.5 |
| 3 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer- In-charge complete in all respect.
SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer | 177.5 | Sq.M. | 141.2 | ₹25,063 |
| 4 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and
directions of Engineer-in-charge.
Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75 mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).
25 mm average thickness in 2 layers. | 177.5 | Sq.M. | 587.35 | ₹1,04,254.63 |
| 5 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5
sq.meters and under, including cutting the patch in proper shape, raking
out joints and preparing and plastering the surface of the walls complete,
including disposal of rubbish to the dumping ground, all complete as per
direction of Engineer-in-Charge.
With cement mortar 1:4 (1 cement : 4 fine sand) | 166.96 | Sq.M. | 547.4 | ₹91,393.9 |
| 6 | 6 mm cement plaster of mix :
1:3 (1 cement : 3 fine sand) | 168.2 | Sq.M. | 300.45 | ₹50,535.69 |
| 7 | Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:
Cement Mortar 1:6 (1 cement : 6 coarse sand). | 0.41 | Cu.M. | 6,295.15 | ₹2,581.01 |
| 8 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. External work
PN - 10 Pipe, 50 mm OD (SDR-11) | - | Metre | 450.95 | - |
| 9 | Sub Total | - | - | - | - |
| 10 | Modified Estimated cost after using correction factor on DSR 2023 on account of GST @0.973 on Sub Total as per office memo efile no. 9158977, Central Public Works Department, Government of India. | - | Nos. | 0.97 | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.87 MB
2911.pdf
Tender Documents • 0.51 MB
DLP.pdf
Other Document • 1.17 MB
BOQ_5098531.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .