Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 CrAdmitted-Finance NOT SPECIFIED | ₹8.7 Cr | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | MARYMATHA INFRASTRUCTURE PVT LTD L1 |
|---|---|---|---|---|
| 1.00Well cum pump house 9m Dia | ||||
| 1.00 | 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared | 405 | sqm | 25 ₹10,125 Lowest |
| 1.00 | OD137884/2024-2025:Constructing temporary bund and sand island for fixing equipment for well construction and allied works using sand bags. | 471 | cum | 10,000 ₹47,10,000 Lowest |
| 1.00 | 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | 32.4 | cum | 480 ₹15,552 Lowest |
| 1.00 | 100.3.9.1:Earthwork in open well excavation (above water) for wells of diameter above 9.0m and up to 12.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift up to 1.5m including neat banking. | 224.27 | cum | 500 ₹1,12,135.5 Lowest |
| 1.00 | 100.3.9.2:Earthwork in open well excavation (above water) for wells of diameter above 9.0m and up to 12.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 1.50m to 3.00m including neat banking. | 224.27 | cum | 600 ₹1,34,562.6 Lowest |
| 1.01 | 100.3.9.3:Earthwork in open well excavation (above water) for wells of diameter above 9.0m and up to 12.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 3.0m to 4.50m including neat banking. | 224.27 | cum | 700 ₹1,56,989.7 Lowest |
| 1.01 | 100.3.9.4:Earthwork in open well excavation (above water) for wells of diameter above 9.0m and up to 12.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 4.50m to 6.0m including neat banking. | 224.27 | cum | 800 ₹1,79,416.8 Lowest |
| 1.01 | 100.3.9.5:Earthwork in open well excavation (above water) for wells of diameter above 9.0m and up to 12.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 6.0m to 7.50m including neat banking. | 224.27 | cum | 900 ₹2,01,843.9 Lowest |
| 1.01 | OD137885/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 9m (7.5m to 9.0m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures) | 224.27 | cum | 3,000 ₹6,72,813 Lowest |
Tender Value
₹6.3 Cr
EMD Value
₹2 L
Closing Date
14 Jul 2025, 3:00 pmClosed
Superintending Engineer
Kerala Water Authority, P.H Circle, Kochi-11
Jal Jeevan Mission JJM JJM WSS to Aikkaranadu Mazhuvannoor and Kunnathunadu Panchayath Construction of 9 m dia well cum pump house General Civil Work
2025_KWA_771793_1
Re-E-Tender No. 06/2025-26/SE/PHC/CHN
Open Tender
Civil Works - Water Works
Item Rate
365 days
Aikkaranadu Mazhuvannoor and Kunnathunadu
Please refer Tender documents.
9 documents required · 9 mandatory
₹13,010
₹2 L
Kerala Water Authority, P.H Circle, Kochi-11
23 Oct 2025
27 Jun 2025
15 Jul 2025
27 Jun 2025
14 Jul 2025
27 Jun 2025
27 Jun 2025 - 2 Jul 2025
2 Jul 2025
Amount
Well cum pump house 9m Dia
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
OD137884/2024-2025:Constructing temporary bund and sand island for fixing equipment for well construction and allied works using sand bags.
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
100.3.9.1:Earthwork in open well excavation (above water) for wells of diameter above 9.0m and up to 12.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift up to 1.5m including neat banking.
100.3.9.2:Earthwork in open well excavation (above water) for wells of diameter above 9.0m and up to 12.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 1.50m to 3.00m including neat banking.
100.3.9.3:Earthwork in open well excavation (above water) for wells of diameter above 9.0m and up to 12.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 3.0m to 4.50m including neat banking.
100.3.9.4:Earthwork in open well excavation (above water) for wells of diameter above 9.0m and up to 12.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 4.50m to 6.0m including neat banking.
100.3.9.5:Earthwork in open well excavation (above water) for wells of diameter above 9.0m and up to 12.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 6.0m to 7.50m including neat banking.
OD137885/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 9m (7.5m to 9.0m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD137886/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 10.5m (9m to 10.5m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD137887/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 12m (10.5m to 12m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD137888/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 13.5m (12m to 13.5m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD137889/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 15m (13.5m to 15m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD137890/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 16.5m (15m to 16.5m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD137891/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 18m (16.5m to 18m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD137892/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 19.5m (18m to 19.5m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD137893/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 21m (19.5m to 21m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD137894/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 22.5m (21m to 22.5m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD137895/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 24m (22.5m to 24m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD137896/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 25.5m (24m to 25.5m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
OD137897/2024-2025:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) depth above 15m
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
OD137898/2024-2025:Design manufacture and supply of HOT overhead traverse trolly crane 5 tonne capacity chain pully block and geared trolley having wall to wall horizontal movement etc for smooth functioning of the crane as per IS specification including all fittings and all incidental charges including painting the exposed surface with following specifications type and construction of crane single gurder HOT (Design code IS 3832) Hook IS 8610 Load chain IS 6216 (alloy steel grade 80) Hand chain IS2420 MS Grade 30 break type self actuating screw fiction and disc type
OD137899/2024-2025:Erection lubrication testing and commissioning of HOT overhead crane over the existing RS joist provided by KWA fixed on corbell of RCC pillars and also fixing the end of LT girder to the sides suitably and also providing with suitable end steppers including provision for box type carriage fabricated from rolled steel section and fixtures and drives like gears wheels axies rubber buffers bearing etc. the work also consist of all tools and equipments, labour supervision, load testing all safety devices and commissioning the crane after completion of work all in respect
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
21.1.1.3:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron )
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
21.17:Providing and fixing anodised aluminium grill ( anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.(Only weight of grill to be measured for payment ).
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
13.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
16.21:Engraving letters in hard stone
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
OD141737/2024-2025:Providing and fixing Kirloskar Electric Actuated CI IS 14846 Sluice Valve 600mm PN1.6 ,Cast Iron BODY &Wedge ,Shaft :-SS410 ,Seat :Bronze,Wedge Ring :Bronze, Operation By Auma 3 ph 415 VElectric Actuator
100.98.468:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 600mm.
100.98.124:Supply of DI K9 Pipe Conforming to IS 8329/2000, 600mm Dia.
18.30.12:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:600 mm diameter pipe
18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia
100.31.2.12:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 600mm diameter, Class II.
OD202893/2024-2025:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :600 mm dia Ductile Iron Double Flanged below 12m from ground level and under water laying
Pump sets
Transformer
OD137840/2024-2025:Supply of all materials and providing 11KV Double pole structure using 2nos. 175x85mm. ISMB joist of 9.5M height, 100x50mm. GI chanel cross arms, 1set 3 pole of 400A, 11KV gang operated AB switch with operating handles of required length,1 set of 9.6KV,6KA Lightning Arrestors, 1 sets (3 nos) of 11KV, D.O fuses, Pin insulators, Disc insulators and inter connections of the above items using 8mm dia copper wire with proper copper sockets , including all associated civil works and painting of all structurers with two coats of zinchromate primer and aluminium paint etc. and earthing using 5 nos of 3m GI earthing pipes and inter connection complete as per standard construction practices approved by Kerala Electrical Inspectorate and relevant standards -AT WELL SITE
OD137841/2024-2025:Supply, erection, testing and commissioning of 11KV, 630A, 350MVA, 26.3KA,3sec totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and draw out type vacuum circuit breaker fitted with manual/motor operated spring charge mechanism with 230V AC motor and motor control switch,shunt trip coil of 24 volt DC auxiliary contact 6NO+6NC, Mechanical ON/OFF indicator, Mechanical operation counter, Anti pumping feature, Automatic safety shutters and push button etc, Three panel system (1 no. VCB as incomer and 1 Nos. VCB and 1 No LBS as outgoings ) suitable for installation in 3 phase , 3wire, 50Hz. AC,11kv, effectively earthed supply system,comprising of motorised and spring assisted, protective relays etc. draw out type resin cast 11/0.1 KV PT ,150VA Class 0.2S and * /5A , Class 0.2S ,15VA current transformer for KSEB metering and provision for fixing TOD Meter with sealing arrangement and with controlling fuses for both side .2 class Dual core CT , LED panel lamps , panel heaters etc complete as approved by Kerala Electrical Inspectorate and relevant standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections.Also the panel should have metering facilities as per kseb specifications The cost of control cables both internal and external shall be included in the cost of HT panel, 11KV Switchgear (Indoor) -AT WELL SITE
OD137842/2024-2025:Supply, Erection, testing and Commissioning of Transformer 630 KVA 11KV/3.3KV Indoor Type ,Resin Cast ,ANAN copper wound transformer (KEL/TELK/BHEL /approved reputed make) with off load tap changer (+)5% to (-)10% in steps of 2.5% with standard fittings conforming to IS 1180(EEL?2). HT side and LT side cable box suitable for XLPE cable termination and with energy efficiency level I, . as per IS specification. Guarantee period 12 months from date of commissioning -AT WELL SITE
OD137843/2024-2025:Neutral Grounding Resistor, Design,engineering, supply erection,testing and commissioning of indoor type 3.3KV stainless steel make neutral grounding resistor in sheet steel enclosure with IP 23 degree protection with siutable neutral CT for REF protection. The cubicle shall be fabricated out of 3mm sheet steel and painted with anti –rust primer coating followed by two coats of paint of approved shade, as per standards. The resistance shall be of Kerala Electrical Inspectorate and relevant standards. Armoured 2.5 Sqmm copper control cable shall be used for all external interconnections. The cost of control cables both internal and external shall be included in the cost of NGR
OD137844/2024-2025:Supply, erection, testing and commissioning of 3.3KV, 400 A, 350MVA, totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and draw out type panel board comprising of 1Nos. Vacuum Circuit Breaker as incomer, 3nos. Vacuum Circuit breakers as outgoing The incomer switchgears, & outgoing switch gears should be of draw out type trip free VCBs with suitable overload, Earth fault and short circuit protection releases and Standby Restricted Earth fault relay through the neutral CT provided, suitable UV and shunt releases for probable integration to control wiring including PLC unit and its auxiliary systems for remote monitoring and operation and provision for future up gradation to SCADA, suitable for installation in 3 phase , 3wire, 50Hz. AC, 3.3kv, effectively earthed supply system, comprising of motorized and spring assisted, independent, trip free closing mechanism and all metering equipment, MC 61A high set numerical protective relays, . resin cast, 3.3 KV /110/230V PT with control fuse for each incomers 0.2 class dual core CT LED panel indicates digital multi-function meters, with minimum features to read V, A, Hz, PF, THD % in all the outgoing feeders and incomers including suitable CT/PT and protection arrangements, panel, heaters with timer/RTD based automatic operation, suitable SMF battery and battery charger arrangements etc.. Complete as approved by Kerala Electrical Inspectorate and relevant standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections. The cost of control cables both internal and external shall be included in the cost of 3.3KV panel, 3.3KV Switch gear. Two of the outgoing VCBs shall be provided with suitable interlocking mechanism so as to operate one at a time-AT WELL SITE
OD137845/2024-2025:Supply, erection, testing and commissioning of , 63 KVA, 11KV/433V. 3phase, 50Hz,Dyn 11,. Resin cast , Indoor type copper wound distribution transformers, with HV and LV side cable end box arrangements complete with all fittings as per IS 1180 L2 and Kerala Electrical Inspectorate norms and conforming to IS1180 ( Part 1 ). Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections . The cost of control cables both internal and external shall be included in the cost of Transformer.
OD137846/2024-2025:Supply and installation of MSB panel board for 63KVA Transformer with incomer-1no 125A microprocessor based mccb with 3 O/C and E/F release and stand by earth fault relay as and outgoing 100A 4p MCCB-1 nos, 63A 4p MCCB -4nos, EFR, indications,MFM with RS485 1 nos, voltmeter, 1 nos ammeter with suitable current transformer, suitable busbar and control wiring etc
OD137847/2024-2025:HT Power Cables - Supply & laying 11KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.), cores laid up, inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable of the following sizes in the existing cable trench conforming to IS: 7098 part II 1985 with latest amendments. 3C x 300 Sqm
OD137848/2024-2025:HT Cable Terminations - Supplying and making indoor cable end termination with heat shrinkable jointing kit, including lugs and other jointing materials, for following sizes, XLPE aluminium conductor cable of 11 KV grade as required. 3C x 300 Sqmm
OD137849/2024-2025:HT Cable Terminations - Supplying and making outdoor cable end termination with heat shrinkable jointing kit, including lugs and other jointing materials, for following sizes, XLPE aluminium conductor cable of 11 KV grade as required. 3C x 300 Sqmm
OD137850/2024-2025:HT Power Cables - Supply & laying 3.3KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.), cores laid up, inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable of the following sizes in the existing cable trench conforming to IS: 7098 part II 1985 with latest amendments. 3C x 240 Sqmm
OD137851/2024-2025:Supply of all materials and providing end termination of the following size/suitable size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards.3 core 240 Sq.mm.3.3kv,XLPE AL Cable(Indoor)
OD137852/2024-2025:HT Power Cables - Supply & laying 3.3KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.), cores laid up, inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable of the following sizes in the existing cable trench conforming to IS: 7098 part II 1985 with latest amendments. 3C x 150 Sqmm
OD137853/2024-2025:Supply of all materials and providing end termination of the following size/suitable size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. 3 core 150 Sq.mm.3.3KV,XLPE AL Cable(Indoor)
OD137854/2024-2025: ON-OFF Push button station with ON and Emergency Off button in suitable weather proof enclosure
OD137855/2024-2025:Substation yard fencing:- Supply of all materials and providing substation yard fencing using 50 x 50 x 6 mm angle iron frame work of size 1500 x 2500 mm fitted with weld mesh of 10 gauge and bolted the same to 100 x 50 x 6 mm vertical chanel erected at 1500 mm c/c and 2500 mm above ground level of sub station yard and 500 mm below with 300 x 300 mm plain cement concrete ( 1:3:6) base using 40 mm granite aggregate and top surface finished neat and including all associated civil works and painting of all structures with two coats of zinchromate primer and aluminium paint etc. complete as per standard construction practices approved by Kerala Electrical Inspectorate and relevant standards.
OD137856/2024-2025:Supply and fixing of 2 m x 1.8m size gate with 40X40X6mm angle frame with 3 Nos MS flat central cross support of 25X6mm flat iron and 10mm rod as vertical welded with 10cm apart to the gate frame hinged to the existing fencing pole, providing locking arrangements and painting 2 coats of aluminium paint over 2 coats of epoxy primer
OD137857/2024-2025:Supply, fabrication,assembling and providing MS ladder type cable tray with necessary supports made out of suitable size MS angles/ flats etc. including painting with 2 coats of enamel paint over 2 coats of red oxide primer.
OD137858/2024-2025:Supply and providing plate earthing as per IS 3043 with 1200x1200x12 mm GI/CI earth plate, 50 mm GI watering pipe fixed to the earth plate with 25 x 3mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 450 x 450 x 450 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top.
OD137859/2024-2025:Supply and providing pipe earthing as per IS 3043 by using Earthing G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
OD137860/2024-2025:Supplying and fixing cable route marker with 10cmx10cmx5mm thick G.I.plate with inscription there on,bolted /welded to 35mmx35mmx6mm angle iron,60cm long and fixing the same in ground as required
OD137861/2024-2025:Supply and providing following safety items. 6 mm thick rubber mat 0.90 m wide 1.80 m long ISI marked- 3 nos, DCP type fire extinguisher 5 kg (ISI marked) - 2 nos, CO 2 type fire extinguisher 5 kg (ISI marked)- 2 nos, fire bucket with floor mounting self stand - 2 nos, shock treatment chart duly framed with glass cover - 2 nos, 11 KV gloves - 2 pair, danger baord - 6 nos, first aid box with medicine - 1 box,earth rod of 3. m long 1no etc.
OD137862/2024-2025:Charges for preparation of electrical scheme and getting energisation approval (including clearing defects if any) from electrical inspectorate.Statutory fee excluded from the cost (statutory fee shall be done by KWA)
OD137863/2024-2025:Supplying and laying of 25x5 mm size copper earthing conducters along with cable/duct bellow ground including connection/ terminating with nut bolt spring wash etc are required
OD137864/2024-2025:Transportation ,erection testing and commissioning of 3.3 KV panels,11KV Panels MSB and SSB
OD137865/2024-2025:Supplying and wiring points according to IS 732 is using rigigid pvc pipes using 1sqmm FR PVC insulated stranded single core copper conductor etc. complete as per sepecification (Sl no. 120) single control light point ( rate as per SI 120a1)
OD137866/2024-2025:Supplying and fixing yard lighting with GI pole and LED light
OD137867/2024-2025:Supplying and wiring points according to IS 732 is using rigigid pvc pipes using 1sqmm FR PVC insulated stranded single core copper conductor etc. complete as per sepecification (Sl no. 120) single control celing fan with electronic regulator ( rate as per SI 120a7)
OD137868/2024-2025:Supplying and wiring points according to IS 732 is using rigigid pvc pipes using 1sqmm FR PVC insulated stranded single core copper conductor etc. complete as per sepecification (Sl no. 120) single control light point with 6 A 5 pin plug ( rate as per SI 120a3)
OD137869/2024-2025:Supplying and laying one number PVC insulated and PVC sheeted / XLPE/ power cable of 1.1 KV grade following size in masonry open duct as required (Supply and Laying of 3x2.5 sqmm copper armored cable)
OD137870/2024-2025:Supplying and laying of following size of 1.1 KV grade PVC insulated armored heavy duty aluminium cable as per I S through built-in trenches/ cable trays including clamping 3.5 x 95 sq mm ( two run) with cable end termination
OD137871/2024-2025:Supply,conveyance,installation,testing and commissioning of 1200 mm sweep-5 star rated ceiling fan using standard accessories excluding resistant type regular ,wiring the down rod with 16/0 .2mm PVC insulated and PVC sheathed 650/1100 V grade 3 core round copper conductor flex wire or with extended with original wiring as requied
OD137872/2024-2025:cabling )supply laying testing and commissioning of the following size.PVC XLPE insulated shelthed armoured aluminium conductor cable 1100 volts grade clamped on wall / ceiling with Clamps and saddle clips partly laid in cable tray partly laid in trench for 4Cx16 sq mm PVC XLPE aluminium cable including cable end terminations
OD137873/2024-2025:supply and wiring light points with 6A plate ceiling of according to various 732- 1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 3419 -1988 fixing the conduit using methyl saddles spacing not exceeding 50cm concealed suitably and with 1 sq mm FR PVC insulated standed single core copper conductor cable 650 B grade including providing switch board main and continuous earthing earth socket brass Bolt and nuts crimpling soldering etc compete with suitable size modular type of metal switch boxes modular type of front plates (white) etc up to and including 6A modular type SP switches and making good the surface of wall colour washing etc complete all the terminations in switich boards and the DB"s shall be tinned and wires shall be drawn and fixied along the Periphery of the box using suitable Ties tie mounts etc. as require
OD137874/2024-2025:Supply, conveyance and installation testing and commissioning the light fittings of 1200 mm 1- 20 w LED lamp with box type fluxure made from CRCA sheet 0.5 mm thickness with all accesseries and lamps directly on wall and giving connections with 16/0.2 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required.
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
OD137875/2024-2025:Towards the charges for deposit to KSEB for additional post, cable laying, line extension etc. if any as per direction.
OD137876/2024-2025:Arrangements of soil resistivity certificate
OD137877/2024-2025:Charges for obtaining certificate from electrical inspectorate excluding statutory and sundry charges
OD137878/2024-2025:PAYABLE TO KSEB-Drawing 1Km of 11 kV ABC of size 3X120 + 1X95 on 9 mts supports with an average span of 20-25 mts
OD137879/2024-2025:TOD Meter-Supply, erection, testing and commissioning of TOD meter of reputed make, 11KV/110V, -/5A, Class.2s with downloading facility. Include the cost of testing the meter at KSEB and all other incidental expenses.- At RAW water pump house
OD137880/2024-2025:Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 6 way (4 + 18), Double door (DSRE 2-4-2)
OD137881/2024-2025:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.-Single pole
OD137882/2024-2025:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required- 63A
Bidder Name
MARYMATHA INFRASTRUCTURE PVT LTD
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
BOQ.xls
BOQ • 0.40 MB
Tenderdocument.pdf
Tender Documents • 1.54 MB
Tenderdocument_2.pdf
Tender Documents • 2.51 MB
Tenderdocument_3.pdf
Tender Documents • 6.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .