Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC GARUBANDHA MISSAMARI DIST SONITPUR ASSAM 784506 | SONITPUR | ASSAM | 784506 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹31.3 L+₹2.4 L (8.49%)Rejected-Finance MISSAMARI DIST SONITPUR ASSAM 784 506 | SONITPUR | ASSAM | 784506 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹32.4 L+₹3.6 L (12.5%)Rejected-Finance POST MISAMARI DIST SONITPUR ASSAM 784 506 | SONITPUR | ASSAM | 784506 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | Rejected-Technical HARIGAON PO NIKAMUL SATRA DIST SONITPUR ASSAM PIN 784001 | SONITPUR | ASSAM | 784001 | - | Rejected-Technical NON VALIDATED (EMD NOT UN-ENLISTED) |
Tender Value
₹36.9 L
EMD Value
₹73,880
Closing Date
25 Apr 2024, 6:00 pmClosed
GE MISSAMARI
PO-Missamari Dist-Sonitpur Assam
SPECIAL REPAIRS TO ROOF TREATMENT OF BLDG NO P-1 TO P-20 AT MH HOSP COMPLEX AT MH UNDER GE MISSAMARI
2024_MES_646517_1
8452
Open Tender
Civil Works
Item Rate
210 days
GE MISSAMARI
AS PER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹500
GE MISSAMARI
₹73,880
Yes
30 May 2024
14 Mar 2024
27 Apr 2024
14 Mar 2024
25 Apr 2024
8 Apr 2024
21 Mar 2024 - 25 Mar 2024
Amount
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed..
Demolition of brick work or stone/ boulder masonry built in cement mortar or cement lime mortar including removal to rubbish from the site complete all as specified and as directed.
M&L for brick work with subclass 'B' bricks straight or curved on plan exc 6M means radius built in cement mortar 1:6 complete all as specified and as directed..
M&L for 15mm thick plaster on fair faces of brick work or concrete surface in cm (1:4) with WPC as per manufacturer instruction fair face of concrete brick work to wall surface finished the surface even and smooth without using extra cement complete all as specified and as directed..Note: WPC shall be measured and paid separetely
Supply only Integral water proofing compound,complete all as specified and as directed.
Removing complete existing treatment including PCC pedding of roof surfaces by picking, sweeping clean and washing down with water to remove dust etc average tkickness not exc 25mm omplete all as specified and as directed. Note: Removing existing earth strip and refixing the same is deemed to be included in the unit rate quoted including insolators, screws as requried.
M&L for brushing neat cement slurry with 03 Kg of cement per Sqm,complete all as specified and as directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 complete all as specified and as directed. . Note:( water proof compound measured seperately)
M&L 25 mm thick cement concrete PCC Type B0 1:2:4 (using 12.5 mm graded aggregate) complete all as specified and as directed..
M&L 3mm thick APP based polymeric membrane minimum weighing and reinforced with polyster non woven laid fabric (wt. not less than 150 gms/sqm) on primed surface by forced application including coating the surface with water based bituminous primer blow bitumen of 85/25 at 1.2 Kg/Sqm both at bottom and top of the membrance and finally finished with one coat of bitumenous aluminium primer at 100 gm per sqm complete all as specified and as per manufacturer's instrcutions. Note : Work shall be carried out by manufacturer or his Authorised applicator of manufacturer.
Taking down rain water pipes of any dia/description inculding all fittings any size and pattern,complete all as specified and as directed.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls,complete all as specified and as directed..
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes double socketed in any length with rubber ring joints fixed in walls,complete all as specified and as directed..
S & F 110 mm bore PVC (SWR) bends of any radius,complete all as specified and as directed..
S & F 75 mm bore PVC (SWR) bends of any radius,complete all as specified and as directed..
S & F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door,complete all as specified and as directed.
Supply and laying 20 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including taking up or down existing unserviceable 15 mm bore steel tubing & connections/ fittings complete all as specified and as directed
Supply and laying 25 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including taking up or down existing unserviceable 20 mm bore steel tubing & connections/ fittings complete all as specified and as directed.
Supply and laying 32 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including taking up or down existing unserviceable 25/32 mm bore steel tubing & connections/ fittings complete all as specified and as directed.
Material & Labour for preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm over new surface over 1 mm thick wall care putty,complete all as specified and as directed..
S&F 500 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore ball brass valves, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed including dismantling existing unserviceable PVC water tank complete all as specified and as directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position capacity exc 250litre and not exc 500 litre complete all as specified and directed
M&L for providing cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate as in roof kerbs or mud stops rounded or chamfered on edge complete all as specified and directed
MAA CONSTRUCTION
RC Madan
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .