Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹81,211Accepted-AOC 676521 | MALAPPURAM | KERALA | 676521 | ₹81,211 Quoted ₹81,210.93 | 1 | Accepted-AOC lowest |
| 2 | 2₹84,682.93+₹3,472 (4.28%)Rejected-AOC NOT SPECIFIED IN THE DOCUMENT | ₹84,682.93+₹3,472 (4.28%) | 2 | Rejected-AOC 2 nd lowest |
| 3 | 3₹88,917.08+₹7,706.15 (9.49%)Rejected-AOC | ₹88,917.08+₹7,706.15 (9.49%) | 3 | Rejected-AOC 3 rd lowest |
Tender Value
₹84,683
EMD Value
₹2,117
Closing Date
18 Jun 2026, 4:00 pmClosed
ASSISTANCE EXECUTIVE ENGINEER
PWD ELECTRICAL SUBDIVISION MALAPPURAM
GENERAL-Urgent Repair Rest House Manjeri-Urgent Repair to Electrical Installation and Air conditions at Rest House Manjeri.- General Electrical Work
2026_PWD_855127_1
ELSDM -10/2026-27
Open Tender
Electrical Works
Percentage
MANJERI
Please refer Tender documents.
12 documents required · 12 mandatory
₹555
₹2,117
20 Jul 2026
11 Jun 2026
22 Jun 2026
11 Jun 2026
18 Jun 2026
11 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Maintenance and Repair | |||||
| 1.001 | OD42868/2026-2027:Maintenance and servicing of 1/1.5/2/3 TR, 240/415V Air Conditioner Units( vertical and wall/floor mounting type ) split AC units such as cleaning and servicing of indoor and outdoor unit using chemical materials, water pump, cleaning material and pressure air pump etc. also including attending minor petty repairs , rectifying defects if any- including the material) and maintaining of indoor and outdoor unit in proper working condition. | - | each | 1,166.48 | - |
| 1.002 | OD42869/2026-2027:Supply and charges for filling sufficient quantity of Freon 22/410 A gas for existing air conditioner unit including leak testing rectifying the defects leak arresting including brazing and make the compressor in good working condition for the following. 1 TR/1.5 TR/2 TR/3 TR | - | kg | 1,482.43 | - |
| 1.003 | OD42870/2026-2027:Supply and providing following size soft drawn Copper pipe for extending pipe between out door and indoor units including insulating pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc. 1/4"(6.35mm) and 1/2"(12.7mm) 22 gauge | - | metre | 1,790.38 | - |
| 1.004 | 90.6.5.13:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 4.00 sq mm | - | metre | 145.47 | - |
| 1.005 | OD35688/2026-2027:Supply and fixing 5 star rated 10Ltr water heater with nylon hose and giving connections
(V-Guard / Racold / AO Smith) | - | each | 10,730.63 | - |
| 1.006 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | - | point | 1,551.58 | - |
| 1.007 | OD42871/2026-2027:Supplying and fixing 9W LED Bulb. as required. | - | each | 193.4 | - |
| 1.008 | OD165211/2023-2024:Supply, Conveyance, installation, testing and commissioning of 1000 lumen round/ square round/square surface/recess mounting made of die cast aluminum, having efficiency not less than1101/W, pf greater than 0.95, THD less than or equal to10%,
type LED fitting duly wired up for use on 230 V AC supply. and
giving connections as required.(Bajaj/Philips/Polycab/Havells/Crompton) | - | each | 1,711.74 | - |
| 1.009 | 90.3.20.3:Supply & installation of light fittings on TW round block
Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture | - | each | 1,260.53 | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_1445306.xls
BOQ • 0.33 MB
viewsbd.pdf
Tender Documents • 3.35 MB
0448591026963700List.pdf
Other Document • 0.19 MB
04493310269642001ElectricalworkGenConditions.pdf
Other Document • 0.58 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .