| 1 | 1₹15.0 LAccepted-AOC 34 1 TILAK NAGAR KOLKATA 700040 | KOLKATA | KOLKATA | WEST BENGAL | 700040 | 1 | Accepted-AOC LOWEST BID | |
| 2 | 2₹17.6 L+₹2.6 L (17.6%)Rejected-AOC B 13 109 NIMTALA BUS STAND KALYANI NADIA | KALYANI | NADIA | WEST BENGAL | 2 | Rejected-AOC SECOND LOWEST BID | |
| 3 | 3₹20.0 L+₹5.0 L (33.5%)Rejected-AOC 00 BALITIKURI BALITIKURI NASKARPARA HOWRAH WEST BENGAL 711113 | HOWRAH | WEST BENGAL | 711113 | 3 | Rejected-AOC THIRD LOWEST BID | |
| 4 | Rejected-Technical 39 RIFLE RANGE ROAD KOLKATA 19 | KOLKATA | KOLKATA | WEST BENGAL | 700019 | - | Rejected-Technical Bidder has not responded against query of shortfall documents. |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
14 Dec 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE PWD CEC
Central Electrical Circle, P.W.Dte 184, C.R.Das Road, Berhampore, Murshidabad, PIN-742101TelNO.03482-261581 / 6292121856,
Repairing and renovation of EI work at Central Library at the Kalyani University, Kalyani, Nadia --- EI Work
2021_WBPWD_350305_1
WBPWD/CEC/eNIQ/12/Q/2021-22
Open Tender
ELECTRICAL WORKS M/R
Item Rate
45 days
Kalyani University
Please refer Tender documents.
4 documents required · 4 mandatory
₹40,000
VIRTUAL WEBPLATFORM
7 Jan 2022
12 Nov 2021
16 Dec 2021
12 Nov 2021
14 Dec 2021
19 Nov 2021
18 Nov 2021
120 days
Amount
Sub-Head 1--Distribution Wiring Distribution wiring in 1.1KV grade 2x22/0.3(1.5 sq.mm) single core stranded FR PVC insulated & unsheathed copper wire (Gloster/Polycab make) approved by the EIC partly in 20mm size PVC rigid conduit FR Precision make Medium and also use Precision make accessories accessories for Ceiling portion only and in 19mm bore 3 mm thick Polythene pipe for Horozontal & Vertical run embedded in wall including above false ceiling with 1 x 22 / 0.3 (1.5sq.mm) single core stranded FR PVC insulated & unsheathed copper wire for ECC ,to light/fan / call bell poiunts with Piano key type switch fixed on MS CRC 16 SWG Sheet Switch board embedded on wall complete with 2 nos.``Ph & N'' copper bar including bakelite / perpex top cover 3 mm thick (wall matching Colour) and including 175 x 100 x 65mm inspection box embedded on wall , making earthing attachment painting the MS box and mending good damages to original finish as per GS [E15/5] NB - Only PVC Rigid Conduit on Ceiling Portion & the shaddles should be fixing / maintaing 325mm gap between the saddles ,i.e-325mm interval of saddling and also remaining portion Concealed)
Average run 8 mtr.
Distribution wiring in 1.1KV grade 2x22/0.3(1.5 sq.mm) single core stranded FR PVC insulated & unsheathed copper wire (Gloster/Polycab make) approved by the EIC in 20mm size PVC rigid conduit FR Precision make Medium with1.1KV grade 1x22/0.3 (1.5sq.mm) single core stranded FR PVC insulated & unsheathed copper wire as ECC to 6A 5Pin flush type plug socket & Piano key type switch fixed on MS CRC 16 SWG sheet steel switch board on wall including bakelite/perspex top cover (wall matching colour) 3mm thick and including paintaing the MS box and mending good damages to original finish as per GS
On Board
SUB-HEAD 2-- PLUGS & SOCKETS , AC STARTER S&F 240 V 1no. 6A plug socket & 1 no 20 A Plug Socket with separate 1 no 6A & 1 no 20 A Piano key type switch & indicator flush type (Anchor make) on Sheet metal switch board embedded in wall incl S & F 240x 200x 65 mm on MS CRC (16 SWG) switch board with bakelite top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite cover and making necy. connections as reqd. as to GS
S&F 240 V 3 nos. 6A plug socket with separate 3 nos 6A piano key type switch & indicator flush type (Anchor make) on Sheet metal switch board embedded in wall incl S & F 200 x 150 x 65 mm on MS CRC (16 SWG) switch board with bakelite top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite cover and making necy. connections as reqd. as to GS ( For Computer Board)
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required ( For Normal Refrigerator / Water Cooler / Induction)
Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required ( For Pedestal fan / Normal Aquaguard )
Supplying & fixing 240V 20A flush (Piano) type Socket 5/6 pin Anchor make on 16 SWG CRC sheet metal switch board in wall on surface including S & F 100x100x65 mm CRC sheet metal 16 SWG switch board and bakelite / perspex top cover of 3mm thick by brass screws after making housing for socket by cutting bakelite top cover and making necessary connections as reqired. (For AC machine)
Supplying & fixing 240V 6A flush (Piano) type Socket 5/6 pin Anchor make on 16 SWG CRC sheet metal switch board embedded in wall including S & F 100x100x65 mm CRC sheet metal 16 SWG switch board and bakelite / perspex top cover of 3mm thick by brass screws after making housing for socket by cutting bakelite top cover and making necessary connections as reqired. ( for Projector connection / Wall fan Socket)
SUB-HEAD 3--BDB,PDB,VTPN ETC Supplying and fixing MCB 4 Way SS Enclosure type Distribution board with IP-20/30 protection powder coated provision Ref. no. - 8GB32100RC04 ( Make - Siemens/ Legrand/Schneider ) fixed in wall with iron frame (Painted) after cutting wall & mending good damages to finish including necessary connection with earthing attachment .(For UPS & Conpound Light))
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS ( Make - Siemens/ Legrand/Schneider / L&T )
8Way (Up to 160A ) For lighting
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed / Surface with Flat (25x6mm)Iron Frame (Painted) in wall ...... as per GS .( Make - Siemens/ Legrand/Schneider / L&T )
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed /Surface with flat (25x6mm) iron frame (Painted) in wall ...... as per GS.
2+10 Way( Make - Siemens/ Legrand/Schneider/L&T )
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS( Make - Siemens/ Legrand/Schneider / L&T )
40A DP [For SPN DB - 18nos & MCB Enclosure - 6 nos.)
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS ( Make - Siemens/ Legrand/Schneider / L&T )
6-32 A SP MCB as per instruction of EIC [For TPN DB (108 + SPN DB 180 + 4 Way Enclosure 12]
63A TP [ 7 / D- 6] For VTPN DBs
Supplying and fixing 415V Four Pole MCCB OF Breaking capacity 25 / 35KA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection as per GS ( Make - Siemens/ Legrand/Schneider / L&T )
160A 35KA Breaking capacity
SUB-HEAD 4-- Polythene pipe and wires Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene / Precission Medium Make rigid pipe as per GS. (Polycab/Gloster/KEI/RR KABLE Make)
3 x 22 / 0.3 (1.5 sqmm) (for use Compound Lighting)
2 x 36 / 0.3 (2.5 sqmm)+1 x 22 / 0.3 (1.5 sqmm) as ECC (For Power plug , Computer Plug )
2 x 56 / 0.3 (4 sqmm) + 1 x 36 / 0.3 (2.5 sqmm) as ECC (For Split type A.C Machine existing starter )
2 x 84 / 0.3 (6sq.mm) + 1 x 56 / 0.3 (4 sqmm)
4 x 196 / 0.4 (10 sq.mm) + 2 x 80 / 0.4 (6sqmm) For VTPN DB to TPN DBs incoming
Finishing of the PVC insulated Cu. wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
Cutting Channel of size (40 mm x 40 mm) / (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 13/19/25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles as per GS.
19mm dia 3 mm thick
25 mm dia 3 mm thick
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works
100 mm x 100 mm x 65 mm
150 mm x 100 mm x 65 mm
175 mm x 100 mm x 65 mm
200 mm x 150 mm x 65 mm
240 mm X 200 mm x 65 mm
Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required
100 mm x 100 mm x 65 mm
150 mm x 100 mm x 65 mm
175 mm x 100 mm x 65 mm
200 mm x 150 mm x 65 mm
240 mm X 200 mm x 65 mm
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make Medium ] on wall, ceiling with precision make saddles and other accessories as required and mending good damages to building works as per GS. N.B. - Should be fixing the Saddle maintaining 325mm gap between the saddles)
20 mm size
25mm size
SUB-HEAD 5-- SUPPLY & LAYING OF CABLES Supply of 4 Core XLPE Insulated & Sheathed Armoured Aluminium power cables for Working Voltage up to 1100 Volts of following sizes [ Make Gloster / Polycab / RR KABEL / KEI
70 sq,mm [ Main Panel to VTPN ]
Laying of cable above 3½ core 50 sqmm and upto 3½ c ore 90 sqmm on wall/surface including S & F MS clamps with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting [ 2 (d) / F-1 ] N.B. - Should be fixing the Saddle heavy gauge double screw type maintaining 325mm gap between the saddles)
Laying of cable as below , after cutting floor / pavement / wall / and making holes including embdding the cable at an average depth as below and mending good the damages to original finish by CC morter 5:1 ratio including removing the rubbish .
Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor/pavement/wall etc.
Supplying and fixing compression type gland complete with brass gland , brass ring & rubber ring for dust & moisture proof entry of XLPE / PVC armoured cables as below Dowels make gland.as per GS
4Core 70Sq. mm
Finishing of the XLPE / PVC insulated armoured cable ends by crimping method incl. supplying & fixing solder less socket ( DOWELS ) make , tapes , anticorrosive paste & jointing materials as per GS.
3.5 / 4 Core 70Sq. mm
SUB-HEAD 6-- FIXING OF LED light fittings Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length
Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting
SUB-HEAD 6 - SUPPLY OF LIGHT FITTINGS Supply 90 Watt Outdoor Light Fittings Cat No LST-90-CDL-M (Cromton Greaves Makes )
Supply of 230V 50 Hz 4 ft LED T-8 box type batten with end cap complete with accessories ( Make - Philips)
(i) Philips Make Cat No -TMC 501 P 2 X T-LED 22 W P 3241
(ii) Philips Make Cat No -TMC 501 P 1 X T-LED 22 W P 3241
(iii) Philips make PC body 22Watt LED T-8 2100lm lamp ( type - MAS LED tube STD 1200 mm 18 W 865 T8 I - 2100lm)
Supply 230 V 50 Hz 9 watt LED bulb Phlips make in the existing porcelain holder.
Supplying & fixing indoor commercial recessed mounted 230V 50 Hz LED type Complete false ceiling set Philips (Signify) make Full Glow-High efficiency as per Type - RC 380B LED36S-6500 G5 L60W60 PSU OD and making housing after shifting / cutting false ceiling plate as required including making connection complete also S&F 3x22/0.3 (1.5sq.mm) flexible FR / FRLSH PVC insulated copper wire FInolex / Gloster make 1.10 mtr length.
Supplying & fixing Philips (Signify) make EnduraLED WellGglass Type - BY201P LED 78S CW PSU HE PC surface mounted robust & reliable IP66 & IK08 Protected wellglass LED luminarires wuth PDC housing & polycarbonate diffuser i.e suitable for ceiling & wall mounted with fastner 9mm dia 100mm long including S & F fastner etc as required also making connection complete .
SUB-HEAD 7-- FIXING OF FANS & LED Fittings Supplying & fixing socket type fan regulator (Step Type) Anchor make on existing sheet metal switch board with bakelite / perspex top cover by screw after making housing for regulator knob by cutting bakelite / perspex top cover including making necessary connections etc.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS
Supplying & Fixing MS fan clamp of two piece type for RC ceiling (Size of Flat 40x9mm) as per approved specification as per GS.
Supplying & fixing 2 ft 14SWG down rod in place of damage one.same as (as per original) original dn rod including cutting , drilling , splitting etc complete
SUB-HEAD 8 -- SUPPLY OF FANS Supply of ceiling fans complete with all accessories having the following Model / Cat No. ( Make -Usha)
1200 mm Sweep ( Usha Strikaer )
SUB-HEAD 9 -- SITC OF EARTHING Earthing with 50 mm dia GI pipe (TATA-Medium)x 3.0 Mts.long and 1 x 4 SWG GI (HOT DIP) wire (4 Mts. long) 13 mm dia x 80 mm GI bolts , double nuts , double washers including S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below. a) BY ISI - Medium GI pipe.
S&F earth busbar of galvanized (Hot Dip) MS flat 25x6mm on wall having clearance of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as reqd. as per GS
Connecting the equipments body to earth busbar including S & F 25 x 6 mm galvanised (Hot Dip) MS flat on wall / floor with GI saddles as required and connecting to the equipments including drilling holes , with bolts , nuts , washers etc as per GS.
SUB-HEAD 10 -- Dismanling Works and allied works Dismantling the existing working / non working electrical accessories like all kinds of old wirings , MS conduit pipe , main switches , Main switch netgurd , TPN & SPN fuse DB , MCB DBs , light , fans existing power board , cables , glands , existing working damaged panels , incoming & out going cable connections along with accessories etc as per avaiablity at site during execution job / as per instruction of EIC for making space & installation of new accessories including mending good damages & finish .
L& T Make - 160 A on angle iron frame ( Existing Panel replacing 100 Amp Main switch)
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint
HALDER ELECTRIC
CHAKRABORTY ENTERPRISE
stage.html
html • 0.05 MB
technical_674547.pdf
PDF • 0.38 MB
techsummary_674547.pdf
PDF • 0.38 MB
finance_674547.pdf
PDF • 0.02 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_674547.pdf
PDF • 0.18 MB
WorkOrderLOA12.pdf
PDF • 0.12 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .