Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC | L1 | Accepted-AOC ok | |
| 2 | L2₹25.0 L+₹3.7 L (17.2%)Rejected-AOC | L2 | Rejected-AOC ok | |
| 3 | L3₹25.8 L+₹4.4 L (20.7%)Rejected-AOC | L3 | Rejected-AOC ok | |
| 4 | L4₹25.9 L+₹4.6 L (21.5%)Rejected-AOC | L4 | Rejected-AOC ok | |
| 5 | L5₹26.3 L+₹5.0 L (23.2%)Rejected-AOC | L5 | Rejected-AOC ok |
Tender Value
Refer Docs
EMD Value
₹66,000
Closing Date
21 Jul 2021, 6:00 pmClosed
GE WEST BAREILLY
GE WEST BAREILLY
REPAIR / MAINT OF UNSV SECURITY LIGHTS, STREET LIGHTS AND ALLIED WORKS INCLUDING DAILY MAINTENANCE OF SECURITY LIGHTS AT 06 MTN DIV AOR UNDER GE (W) BAREILLY
2021_MES_453142_1
8934/C/E8
Open Tender
Civil Works
Item Rate
180 days
GE WEST BAREILLY
SCANNED COPY OF ENLISTMENT LETTER IN MES IN RELEVANT CLASS CATEGORYSCANNED COPY OF APPLICATION ON LETTER HEAD OF FIRMSCAN COPY OF DD OF RS 500.00 IN FAVOUR OF GE WEST BAREILLY FROM ANY NATIONALISED OR SCHEDULED BANK SCANNED COPY OF REGISTRATION
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹66,000
Yes
16 Aug 2021
21 Jun 2021
27 Jul 2021
21 Jun 2021
21 Jul 2021
6 Jul 2021
21 Jun 2021 - 5 Jul 2021
Amount
Dismantling of SVL / MVL/ MH / LED light fittings of any capacity from existing poles of any height /type complete all as specified and directed.
Supply only of Integral LED street light driver, enclosed with glass cover frame suitable for following sizes LED light for existing complete all as specified and directed. (a) 30 Watt to 50 Watt
(b) 60 Watt to 72 Watt
Supply only of Integral LED street light module with complete PCB and LED suitable for following sizes of LED street light for existing complete all as specified and directed. (a) 30 Watt to 50 Watt
(b) 60 Watt to 72 Watt
Supply only cable two core PVC insulated and unsheathed multistranded aluminium conductor of size 2.50 Sqmm complete all as specified and directed.
S&F in replacement MCBs TPN 63 Amps,415 Volts 16 KA all as specified and directed.
S&F in replacement MCBs SPN 32/40 Amps,220 Volts 10 KA all as specified and directed.
S&F in replacement MCBs Single Pole 6-32 Amps 10 KA ,220 Volts all as specified and directed.
Supply and fix in replacement new generation energy saving & environmental friendly long life versatile pressure die- cast aluminium IP 66 roadway luminaire with high power LED as light source and electronic driver of following capacity including necessary connections with 2.5 sqmm aluminum wire complete all as specified and as directed. Make : Crompton/C&S/polycab (a) 48 Watt
(b) 60 Watt
(c) 72 Watt
(d) 90 Watt
S&F in repair loop-in-loop out box of size 30x20x20cm made out from 1.6mm thick PVC sheet weather proof, dust and vermin proof with hinged door and locking arrangements with slanting cover on top and provision of 4 Nos aluminium bus bar of size 25mm x 2mm-4 Nos fixed on insulator and one MCB of capacity 6 Amps complete fixed on pole with and including suitable size MS flat iron clamps, nuts,bolts & washers etc complete all as specified and directed
S&F in replacement light fitting JETAIRIS Energy saving environmental friendly, exclusive innovative designed, long life versatile pressure die cast aluminium IP-66 flood light luminaire with high power LED 150 W. Make : Havells, C&S or equivalent
S& F in replacement new generation post top energy saving environment friendly, long aesthetically designed with symmetrical light distribution spun aluminium landscap luminaire with power LED of 35 Watt as light source of 35 Watt of Make Havells, C&S or equivalent to Bajaj/Philips
S& F in replacement sturdy LED Bollard with excellent light out through its sleek PMMA window ensuring maximum iluumination aspect in surrounding of 10 Watt complete all as specified and directed. Make Havells, C&S or equivalent
Supply and fixing street light bracket made out of GI pipe light grade 32 mm dia of length upto 1.2 mtr bent to shape required with and including 2 Nos, 50 x 6 mm MS flat iron clamps with nuts, bolts, washer etc and applying one coat of aluminium paint to clamps including dismantling of old brackets complete all as specified and directed.
Supply ,fixing ,commisioning and testing of Nature timer switch control Street Lights complete with MCB, Power and Panel duly complete with wiring Model : SWADEEP-02EC 05KW IP, single phase, max load 05 KW complete all as specified and directed. Note :- CA No & date of installations shall be painted/marked on all timer switch provided by the contractor
Supply ,fixing ,commisioning and testing of Nature timer switch control Street Lights complete with MCB, Power and Panel duly complete with wiring Model : SWADEEP-02EC 12KW3P, three phase, max load 12KW complete all as specified and directed. Note :- CA No & date of installations shall be painted/marked on all timer switch provided by the contractor
S&F in replacement light fitting JETAIRIS Energy saving environmental friendly, exclusive innovative designed, long life versatile pressure die cast aluminium IP-66 flood light luminaire with high power LED 120 W. Make : Havells, C&S or equivalent
S&F 1100 Volts grade heavy duty cable one twin core, flat or circular PVC insulated aluminium stranded conductor of following sizes served with inner sheathing of PVC tapes and overall PVC sheathed in service connection from pole to Main Switch complete all as specified and directed. Make : Havells/ Polycab/Richa. (a) 6 sqmm
(b) 10 sqmm
Excavation in trenches n. exc. 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing of excavated soil to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L local sand dry, filling in trenches around under ground cable complete all as specified and directed.
M&L for providing of new sub class 'B' Bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
Laying only old bricks complete all as specified and directed.
Making horizontal bore hole under road of 50 mm bore size at the depth not less than 1 mtr below ground level for passing of LT underground cable complete all as specified and directed.
S & F in replacement GI pipe light grade for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc of following sizes complete all as specified & directed. (a) 40 mm bore.
(b) 50 mm bore.
Taking out old unserviceable Old LT cable any type and size from trenches or fixed on poles or through pipes/walls/laid under roads/paths/ drains/culverts complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty, conforming to IS - 7098 Part I - 1988 with aluminum conductor 1100 Volts of following sizes / grade laid in ducts or on walls, in trenches encased in GI pipe fixed to walls / laid under roads / drains / paths / culverts etc complete all as specified and directed.
(a) 25 Sqmm 4 core
(b) 16 Sqmm 4 core
(c) 10 Sqmm 4 core
(d) 10 Sqmm 2 core
Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT over head lines conductor upto 3 mtr from furthest conductor on pole including removing of cut branches and cleaning of site complete all as specified and directed. Note :- (a) The trees branches etc will be left as it is and will not be carried away by the contractor / DEL as the wood belongs to CEO / DEO and they will be responsible to lift the wood. (b) Prooning of all tree branches in one tree shall be measured as one Job. (c) Contractor will employ sufficient labour to complete the job with in time as directed. (d) Contractor will be responsible for any type of mis-happening / accident while prooning the trees. (e) Contractor supervisor will take proper shut down from MES installation before starting the work and clear it before resuming power supply . However full assistance will be provided by MES staff. (f) The contractor will provide proper tools and safety devices to his staff for prooning of trees.
Opening the binding wire from pin /shackle insulator on steel pole of any height for re-stretching the ACSR conductor , after re-stretching without kinks & bends, binding the pin /shackle insulator with appropriate size of aluminium binding wire complete all specified & directed by Engineer-in- charge. Note: Cost of binding wire deemed to be included in the quoted rate, No extra amount will be paid.
Dismantling of LT PCC/Steel tubular pole of any size and discription incl coping, foundation etc complete all as specified and as directed.
Supply and erection, in truly vertical position, LT Steel tublar swaged pole complete with cast iron base plate finial taper plug, bolt , nut and screwed type 410 SP 31 09 mtrs long Class -10 including painting of poles with two coats of synthatic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles as directed by Engineer in charge. Note : PCC, Earth work and MS work as cross arms clamps etc will be measured and paid separately.
Material and labour for PCC 1:2:4, using 20mm graded aggregate as in coping to the poles all as specified and directed.
All as per srl item No. 43 here-in-before but PCC 1:3:6 type C-2 as in foundation of stays complete all as specified and as directed.
S&F in replacement stay assembly complete comprising of 20mm dia 40cm long stay bow rod 16mm dia x 1.8 Mtr long stay rod threaded and with nuts including 300mmx300mmx6mm thick plate necessary clamps etc as specified and directed. ( Note : Loop type insulator, stay clamp, stay wire, excavation and concrete measured separately).
S&F in replacement galvanised steel stranded stay wire size 7/4mm for stay assembly complete all as specified and as directed.
S&F in replacement shackle type porcelain vitreous white, brown or green insulator including one galvanised mild steel straps, washers and nut 75 mm height, 90 mm dia for 1100 volts grade, complete all as specified and as directed.
S&F in replacement pin type porcelain vitreous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100 mm height, 65 mm dia for 1100 volts grade, complete all as specified and as directed.
S&F in replacement, fabricating and fixing in replacement of cross arms (any type) supports, bracting, stiffness etc made out of MS channel, angle iron, flat iron of any size including drilling of holes, making clamps, eye hooks, nuts, bolts and washers etc, welding if required including painting with two coats of aluminium paint over a coat of red oxide paint complete all as specified and directed.
S & F in replacement of MCCB 4 pole, 200 Amps 50 Hz 415 V, 36 KA of existing make/model and type alongwith spreader terminal with adjustable thermal setting including lugs/thimbles of suitable size in existing panels complete all as specified and directed by Engr-in-Charge.
All as per Ser item No 39 here-in-before MCCB 3 pole, 125 Amps 50 Hz 415 V, 16 KA.
M&L for cleaning and preparation of old painted surface of LT steel tubular pole complete and painting with one coat of aluminium paint including channels/brackets, street light brackets, cross arms and making Black/Red/Yellow & white strips with synthetic enamelled paint of 30cm height, each alternative strip upto 1.5 mtr height and writing pole numbers with yellow synthetic enamelled paint after making circular base with black synthetic enamelled paint and applying two coat of white wash on PCC coping complete all as specified.
M&L for earthing complete with galvanised or steel earth plate electrode of size 60cm x60cmx6mm thick burried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI wire 4mm dia with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 5 of SSR -1991 Part I and connecting to arthing test point,main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 5 of SSR(Pt-I)1991 complete all as specified and dirfected by Engineer-in-charge.
Supply & fixing in replacement ACSR conductor of any size including binding on existing LT poles or new poles with 02 mm dia aluminium binding wire all as specified & directed.
Day to day maintenance of street lights of 6 Mtn Div AOR by attending street light complaints recived from various user units will be attended immediately and resolved the complaints by using necessary spares as required at site complete all as specified and directed. Notes : Connected items/spares shall be measured & paid separately under relevent items of sch 'A'.
Notes:- 1.The time limit for attending the job/complaints complaints within 24 hour. 2. In case the contracts fails to attend/rectify the defects within the above time limit, penalty will the imposed as under:- (a) Rs 500/- per day per complaints for first seven days after that Rs 1000/- per day per complaint. 3. The contractor or his authorised representative shall report to the Engineer-in-charge or concered JE at 0900 hour daily on all working days to receive order/instructions of the work.
RAZA ENTERPRISES
R.S ENGINEERING TRADERS
sunder and company
VINYAK TRADERS
Vishal Traders
prabhave traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .