Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
2 Dec 2024, 6:00 pmClosed
CWE Ezhimala
CWE Ezhimala Naval Academy Post Kannur 670310
PROVISIONING OF EQUIPMENT AND AC FOR THREE SQUADRONS AS PART OF INFRASTRUCTURE AUGMENTATION AT INA, EZHIMALA NAP PH II
2024_MES_681494_1
CWE/80485/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Ezhimala
AS PER NIT/TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
GE P Ezhimala
₹2.2 L
Yes
31 Dec 2024
26 Oct 2024
4 Dec 2024
26 Oct 2024
2 Dec 2024
18 Nov 2024
26 Oct 2024 - 6 Nov 2024
Amount
Supply, install, testing and commissioning Hi wall 2 TR Capacity 5 star rated Inverter Split AC units , indoor&outdoor complete with cordless remote control unit ,electric driven single phase AC 230 volts,50 Hz including fixing accessories wall mounted with indoor unit, Out door (condensing) unit to be installed on suitable size outdoor mounting brackets duly painted complete in all respect including copper wound compressor,copper refrigerant pipes for suction & discharge lines of standard size recommended by OEM, duly insulated condensate water outlet pipe and 3 core copper cable of required length between stabiliser , indoor & outdoor units,core cutting and fixing suitable size PVC pipe through which the insulated copper pipe will be routed to outdoor unit and making good to surface/wall complete all as specified and as directed. (Computer room -03 Nos.Total 03 x 3 Squadrons=09 Nos) Note:(i)Copper piping both suction and discharge line ,control wiring and drain pipe upto 3 mtr, outdoor mounting brackets of suitable size and all fixing accessories nut,bolts,insulation,initial refrigerant charging included in item rate. (ii)Copper piping ,control wiring and drain pipe beyond 3 Mtr,stabiliser shall be measured and paid seperately. (iii) T&P(Tools and Plants) for installation of ACs shall be provided by the contractor. Make: Daikin, LG, Blue Star
Supply, install, testing and commissioning hi wall 1.5 TR Capacity 5 star rated Inverter Split AC units , indoor&outdoor complete with cordless remote control unit , electric driven single phase AC 230 volts,50 Hz including fixing accessories wall mounted with indoor unit, Out door (condensing) unit to be installed on suitable size outdoor mounting brackets duly painted complete in all respect including copper wound compressor,copper refrigerant pipes for suction & discharge lines of standard size recommended by OEM, duly insulated condensate water outlet pipe and 3 core copper cable of required length between stabiliser , indoor & outdoor units, core cutting and fixing suitable size PVC pipe through which the insulated copper piping will be routed to outdoor unit and making good to surface/wall complete all as specified and as directed. (Guest room -01 Nos, Barber shop -01 Nos.Total 02 x 3 Squadrons=06 Nos) Note:(i)Copper piping both suction and discharge line ,control wiring and drain pipe upto 3 mtr, outdoor mounting brackets of suitable size and all fixing accessories nut,bolts,insulation,initial refrigerant charging included in item rate. (ii)Copper piping ,control wiring and drain pipe beyond 3 Mtr,stabiliser shall be measured and paid seperately (iii) T&P(Tools and Plants) for installation of ACs shall be provided by the contractor. Make: LG , Daikin , Bluestar
Supply, install, testing and commissioning 3 TR 5 Star rated inverter cassette type AC units , indoor&outdoor units complete with cordless remote control unit 3 phase AC 415 volts,50 Hz including all kinds of fixing/hanging accessories for indoor unit , Out door (condensing) unit to be installed on suitable size outdoor mounting brackets duly painted complete in all respect including copper wound compressor,copper refrigerant pipes for suction & discharge lines of standard size recommended by OEM ,duly insulated condensate water outlet pipe and control wiring of required length between indoor & outdoor units , core cutting and fixing suitable size PVC pipe through which the insulated copper piping will be routed to outdoor unit and making good to surface/wall complete all as specified and as directed. (Ante Room-04 Nos.Total 04 x 3 Squadrons=12 Nos) Note:(i)Outdoor mounting brackets of suitable size , angle iron of suitable size and all fixing/hanging accessories for indoor unit, nut,bolts,,insulation,initial refrigerant charging included in quoted rate. (ii)Copper piping for both suction and discharge line ,control wiring and drain pipe shall be measured and paid seperately. (iii) T&P (Tools and Plants) for installation of ACs shall be provided by the contractor .Note:Ante room have varying ceiling height of 3.5m to 4.4m. Make: LG, Daikin, Bluestar
Supply, install, testing and commissioning 4 TR 5 star rated inverter cassette type AC units , indoor&outdoor units complete with cordless remote control unit 3 phase AC 415 volts,50 Hz including all kinds of fixing/ hanging accessories for indoor unit , Out door (condensing) unit to be installed on suitable size outdoor mounting brackets duly painted complete in all respect including copper wound compressor,copper refrigerant pipes for suction & discharge lines of standard size recommended by OEM ,duly insulated condensate water outlet pipe and control wiring of required length between indoor & outdoor units , drilling hole in wall/surface and fixing suitable size PVC pipe through which the copper piping will be routed to outdoor unit and making good to surface/wall complete all as specified and as directed. (Squadron office-05 Nos,Motivation Hall -05 Nos.Total 10 x 3 Squadrons=30 Nos) Note:(i)Outdoor mounting brackets of suitable size , angle iron of suitable size and all fixing/hanging accessories for indoor unit, nut,bolts,insulation,initial refrigerant included in item rate. (ii)Copper piping for both suction and discharge line ,control wiring and drain pipe shall be measured and paid seperately. (iii) T&P (Tools and Plants)for installation of ACs shall be provided by the contractor.Note: Squadron office have varying ceiling height of 6m to 9.8m and Motivation hall have ceiling height of 4.88m. Make: LG ,Daikin,Bluestar
Supply, install, testing and commissioning 1 TR Portable AC with cordless remote control unit , with latest energy efficiency rating, single phase AC 230 volts,50 Hz including fixing accessories and core cutting in wall/surface and fixing suitable size PVC pipe through which the duct/exhaust hose pipe taken outside and making good to surface/walls, all as specified and as directed. (Psycological room/Academic counselling room -02 Nos.Total 02 x 3 Squadrons-06 Nos) Make: BlueStar, LG, Daikin
Supply, install,testing of insulated copper pipes of 6.35mm(1/4") dia and minimum thickness 0.8mm with 13mm(minimum) thick nitrile rubber class 'O' insulation , finished with fibre glass cloth covering for suction and discharge line of compressor complete all as specified and directed. Make: Mandev,Totaline, Mexflow.
Supply, install,testing of insulated copper pipes of 9.52mm(3/8") dia and minimum thickness 0.8mm with 13mm(minimum) thick nitrile rubber class 'O' insulation , finished with fibre glass cloth covering for suction and discharge line of compressor complete all as specified and directed. Make: Mandev,Totaline, Mexflow.
Supply, install,testing of insulated copper pipes of 12.7mm(1/2") dia and minimum thickness 0.8mm with 13mm(minimum) thick nitrile rubber class 'O' insulation , finished with fibre glass cloth covering for suction and discharge line of compressor complete all as specified and directed. Make: Mandev,Totaline, Mexflow.
Supply, install,testing of insulated copper pipes of 15.88mm(5/8") dia and minimum thickness 0.8mm with 13mm(minimum) thick nitrile rubber class 'O' insulation , finished with fibre glass cloth covering for suction and discharge line of compressor complete all as specified and directed. Make: Mandev,Totaline, Mexflow.
Supply and fix PVC Trunking of size 100 x 50 mm for Hi wall split AC copper piping complete all as specified and as directed.
Supply, install,testing of insulated copper pipes of 19.05mm(3/4") dia and minimum thickness 0.8mm with 13mm(minimum) thick nitrile rubber class 'O' insulation , finished with fibre glass cloth covering for suction and discharge line of compressor complete all as specified and directed. Make: Mandev,Totaline, Mexflow.
Supply and fix control wiring of size 2.5 Sqmm 4 Core copper conductor between indoor & outdoor unit including connection with suitable lugs,testing etc complete all as specified and directed. Make:Polycab,Havells,RPG.
Supply and fix PVC drain piping of size 25mm including 13mm(minimum) thick nitrile rubber class 'O' insulation , finished with fibre glass cloth covering for eliminating condensate water complete all as specified and as directed. Make:Supreme,Finolex,Prince pipes fittings.
Supply and fix voltage stabiliser for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stablised at 230V with accuracy of +/- 2.5% and of capacity 4 KVA complete all as specified and as directed. For Computer Room -03, Guest Room-01, Barber Shop-01(Total 05 x 3 Sqn = 15 Nos) Make: V-Guard,Microtek,Luminous.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying UG cable/foundation of poles and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling including spreading, leveling hard/dense soil, watering and well ramming in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50m and depositing where as directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
Spreading and levelling only riddled earth for cushioning and covering of the UG cable in trenches complete all as specified and as directed by Engineer-in-charge. Note:- Punned thickness shall be measured and paid. Excavated approved soil shall be riddled by using seive to seperate composite particles as per IS.
Supply and lay un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm for protection of cable complete all as specified and as directed.
Supply and lay un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx l80mm x 40mm for protection of cable complete all as specified and as directed.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination Heat/cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and as directed. Make: Raychems, Densons, Birla - 3M.
Supply, laying of cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 11000 volts(Earthed) grade with stranded aluminium conductor of size 3 core 185 sqmm including connection with suitable lugs,nut,bolts etc ,testing complete all as specified and as directed by Engr-in-charge.(From existing RMU at 3 Squadron to proposed 315 KVA CSS)
Material and labour for earthing complete with galvanised steel earth plate electrode of size 600mm x600mmx6.0 mm thick burried directly under ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate at a depth not less than 1.5 m below ground level connected to and including galvanised strip 32 x 6mm, by means of bolts, nuts, check nuts and washeres made out of GI including protection pipe GI light grade 40 mm size and watering pipe 20 mm dia GI medium grade all as shown on plate No 3 of SSR Part-I, connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, GI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 140mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed.(CSS-08 Nos) Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh, 40mm dia light grade GI protection pipe for earth lead etc., complete.
Material and labour for earthing complete with galvanised steel earth plate electrode of size 600mm x600mmx6.0 mm thick burried directly under ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate at a depth not less than 1.5 m below ground level connected to and including galvanised strip 25 x 4mm, by means of bolts, nuts, check nuts and washeres made out of GI including protection pipe GI light grade 40 mm size and watering pipe 20 mm dia GI medium grade all as shown on plate No 3 of SSR Part-I, connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, GI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 140mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed.(LT panel-02 Nos.) Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh, 40mm dia light grade GI protection pipe for earth lead etc., complete.
Supply, laying of cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 3.5.core 95 sqmm including connection with suitable lugs,nut,bolts etc ,testing complete all as specified and as directed by Engr-in-charge. (Proposed LT Panel to main VTPN DB at each squadron)
Supply, laying of cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 3.5.core 185 sqmm including connection with suitable lugs,nut,bolts etc ,testing complete all as specified and as directed by Engr-in-charge (2 Run of cable from proposed CSS to Proposed LT panel)
Supply, errection, testing and commissioning 11KV Outdoor Package Sub-Station consisting with the following:- (A) HT SWITCHGEAR (a)11KV 630A 21kA/3s SF6 Insulated Non-Extensible Compact switchgear consisting of 1 No Fixed Type Manual Load Break switch and 1 No. Fixed Type Manual Operated Vacuum Circuit Breakers in SF6 insulated stainless steel enclosure of thickness 2.5mm with series trip, self powered microprocessor based numerical over current relay (IDMTL + Inst.) protection. (Type CV- NE Interconnection between HT switchgear and transformer shall be using 1Cx3x95 Sq.mm Aluminium unarmoured XLPE Cable. 1 No (b) Self powered over current and earth fault protection Relay ( 50,50N,51,51N) with RS 485 communication port .- 1 No (c) CT - 25/1A, 2.5VA, CL - 5P10 for Protection. - 1 set (d) Fault passage Indicator for incoming LBS - 1 No (e) Manometer - 01 No (f) Voltage Presence Indiactor - 3 Nos (g) Operating Handle - 01 Nos
(h) Incoming module of the RMU shall be suitable for cable termination upto 3C X 185 sq.mm Aluminium cable. (B)TRANSFORMER ( As per ECBC 2017) (a) 315kVA 11/0.433KV DYn11 Cast Resin Dry type transformer with Off circuit tap links of range +5% to -5%. Insteps of 2.5%. Class of Insulation: F, Temperature Rise: 90 Deg.C over ambient temp. of 50Deg C, Losses(AS Per ECBC 2017 Losses) Max losses at 50% loading=2000W, Max Losses at 100% loading= 5040W and Impedance of 4.5% (Subjected to IS Tol.) , Surge arrestor on HT side.(b) Winding Temperature Indicator with Alarm and Trip Contact - 01 set (c) Door interlock with the breaker - 1 No (C) BUSBAR: Low Voltage Switchgear - 800A Aluminium BUSBAR ( 100% FOR PHASE AND 100% FOR NEUTRAL , CURRENT DENSITY - 1 A/Sqmm (D) INCOMER (a) MCCB, 630 Amps, 433V 4P 50Hz 36KA 3 Phase Manually Fixed Type MCCB with Microprocessor based release for over current, short circuit and earth fault protection. (b) Metering CT - 630/5A 5VA Class 1 Accuracy - 1 No (c) Digital Multifunction Meter of Class 1.0 Accuracy with RS-485 Port - 1 No (d) RYB,ON,OFF,TRIP LED Indication Lamps - 1 Set (E) OUTGOING SWITCHES (a) MCCB 400 AMPS 433V TPN 36KA Manually Fixed type Molded Case Circuit Breaker with Thermal Magnetic Based over current & short circuit fault release. - 01 Nos (LT panel) (b) MCCB 100 AMPS 433V TPN 25KA Manually Fixed type Molded Case Circuit Breaker with Thermal Magnetic Based over current & short circuit fault Release. - 01 Nos (spare)
(d) Outdoor type enclosure having modular construction of Galvanised Sheet Steel of thickness 2mm with 4mm HRCA baseframe. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure exterior shall be powder coated ( colour Light Gray & D.A.Gray ). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. Seperate Switch operated bulket lamp + Hooter in Transformer compartment - 1 set. (e) Interlock between Transformer Door and HT Breaker , if door opens it trips the main breaker. (F) Interconnection & Earthing Interconnection Between HT switchgear & Transformer using 1Cx3x95Sq.mm XLPE Aluminium Single core cable & Interconnection between Transformer & LT switchgear using Aluminium Busbars. Internal earthing connections by using 50x6 mm Aluminium including for Transformer Neutral. NOTE: Rate quoted shall deemed to be included for the following:- 1. Package Sub-Station is outdoor plinth mounted type. Erection ,Commissiong, Testing at site.Quoted rate shall be inclusive of CSS platform and foundation as per OEM specification. 2. CSS shall be offered with GI sheet steel thickness of 2mm for load bearing member and 1.5mm for non-load bearing members. 3.CSS shall be mounted directly on installation plinth and no base channels are envisaged.
4.Package Sub-station will be complete with the internal interconnections & earthing. including Accessories required for the external connections of HT & LT cables like termination kits , lugs , glands etc. extending of earth bar to earth pits shall be measured and paid separatly. 5.Cable termination arrangement shall be from Bottom for HT & LT side. 6.Interconnection cable between HT side V ( Breaker ) Module to transformer shall be Aluminium - 1Rx3Cx95 sqmm 7.The enclosure exterior shall be powder coated ( colour Light Grey & D.A.Grey) 8.Door of Transformer shall be fitted with Arc reflectors from the inside of providing better safety - It cannot be provided on Transformer door. 9. CSS shall be as per IEC 62271-202. Technical requirements :- • The Compact substation shall be tested for internal arc test IAC –AB for 21KA for 1 sec (A-operator, B-pedestrian). This has to be validated by Type test certificate as per IEC 67721-202 & same shall be submitted along with tender. CSS design, invoicing, ownership, Service responsibility & warranty shall be of OEM on whose name all Type tests are issued. Type tests shall be conducted on CSS as per IEC 62271-202 in the name of OEM.
• CSS, RMU, Vacuum Interrupter bottle, ACB/MCCB shall be of same OEM make on whose name all Type tests are issued.This is to ensure better reliability, quality wokmanship ,performance and service support and overall life cycle optimization. • CSS manufacturer shall fulfill temperature class K10 as per IEC 62271-202 and confirm with suitable report. As CSS is an integrated modular system, CSS manufacturer shall decide & offer good quality transformer make from their end and offer atleast two transformer makes duly checked by CSS OEM team to ensure quality , service & reliability of transformer. Make: ABB,Schneider,Seimens.
Supplying and laying of galvanised iron tube of 50 mm bore, light grade, with all fittings for road crossing, plinth crossing of UG cables complete all as specified and as directed.
Supplying and laying of galvanised iron tube of 100 mm bore, light grade, with all fittings for road crossing, plinth crossing of UG cables complete all as specified and as directed.
Supply, errection, testing and commissioning LT panel board (main) factory made out of CRCA sheet 3 mm thick Outdoor,type,duly powder coated, totally enclosed, with front and rear opening, hinged doors with canopy sloped top projected and raised platform of suitable size, weather and water proof as per IS 8623,compartmentalised inner shell made out of 2 mm thick CRCA sheet,dust and vermin proof, 3phase aluminium bus bar with neutral of size 75x10mm, insulators suitable for 3 phase, 4 wire, LT,AC, 50HZ, 415 volts, 600 Amps capacity complete with necessary locking arrangement including all internal electrical connections, CTs, Digital Multi function meter displaying all parameters like current,voltage,power factor,frequency,KW,KVA,KVAr,Kwh etc, LED indicating lamps etc Affixing MV danger notice plate as suitable location each compartment shall be numbered/lettered all as required and provision of the following:- (To be fixed on 45cm raised PCC plat form with necessary foundation) (a) MCCB 400 Amp 4 pole 36 KA with micro processor release electric draw out type (Incomer)- 01 No including busbar of size 75 x 10mm. (b) 4 pole MCCB 160 Amp, 50 Hz, 415 volt with suitable size busbar and breaking capacity 25 KA - 03 Nos for VTPN DB 4 way at each squadron. (c) 4 pole MCCB 63 Amp, 50 Hz, 415 volt with suitable size busbar and breaking capacity 25 KA - 01 Nos spare. Note: ON/OFF indication light Red/Green shall be provided for MCCBs incomer/outgoing.
Supply and fixing cable route indicator 15cm dia made out of cast aluminium duly marked with size and type of cable fixed on ISA 40X40X6mm angle iron support embedded including in PCC 1:2:4 type B1(300X300X450mm) and steel surface painted with two coats of anti corrosive paint over a coat of red oxide primer including necessary earth work complete all as specified and directed.
Supply and fixing of GI cable tray powder coated of size 150mm x 50mm and min thickness 1.6mm,rust proof painted to match with ceiling colour all as specified and as directed.
Supply and fix sheet metal enclosure double door, VTPN DB, 415V, AC, 4 way with 200 Amps rated busbar MCCB as incomer all as specified and as directed.( VTPN DB-01 Nos.Total -01 x 3 squadrons =03 Nos) Note: MCCB shall be measured and paid separately.
Supply and fix sheet metal enclosure double door, TPN DB, 415V, AC, 4 way all as specified and as directed.(Ante room-01 Nos.Total-01 x 3 squadrons = 03 Nos)
Supply and fix sheet metal enclosure double door, TPN DB, 415V, AC, 6 way all as specified and as directed.(Squadron office-01 Nos,Motivation Hall -01 Nos.Total-02 x 3 squadrons = 06 Nos)
Material and labour for earthing complete with galvanised steel earth plate electrode of size 600mm x600mmx6.0 mm thick burried directly under ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate at a depth not less than 1.5 m below ground level connected to and including galvanised iron wire 4 mm dia, by means of bolts, nuts, check nuts and washeres made out of GI including protection pipe GI light grade 40 mm size and watering pipe 20 mm dia GI medium grade all as shown on plate No 3 of SSR Part-I, connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, GI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 140mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed.(02 Each For 3 Nos VTPN DB & 09Nos TPN DB = 24 Nos) Note : (i) The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh, 40mm dia light grade GI protection pipe for earth lead etc., complete. (ii) GI wire 4 mm dia beyond 7.5 metre shall be measured and paid separately.
Supply, fixing ,testing earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4.00 mm dia GI wire all as specified and directed.
Supply and fix MCB SP 20 Amp 'C ' Curve 240 Volt,10 KA all as specified and directed.(Computer room-03,Guestroom -01,barbershop- 01,counselling room-02) Total -07 x 3 Squadrons = 21 Nos.
Supply and fix MCB TP 63 Amps 'C ' Curve 415 Volt , 10 KA all as specified and directed.(Motivation Hall-01,Squadron office-01Total-02 x 3 squadrons=06 Nos)
Supply and fix MCB TP 40 Amps 'C ' Curve 415 Volt , 10 KA all as specified and directed.(Ante room-01 x 3 Squadrons = 03 Nos)
Supply and fix MCB TP 25 Amps 'C ' Curve 415 Volt , 10 KA all as specified and directed.(Motivation Hall-05,Squadron office-05,Ante room-04 . Total-14 x 3 Squadrons=42 Nos)
Supply and fix MCCB 4 Pole 160 Amps ,50Hz, 415 Volt, with breaking capacity 36 KA all as specified and directed.(VTPN DB 4 WAY-01 x 3 Squadrons = 03 Nos)
Supply and fix MCB FP 63 Amps ,50Hz, 415 Volt, with breaking capacity 10 KA all as specified and directed.(TPN DBs at Motivation Hall-01,Squadron office-01 . Total-02 x 3 squadrons=06 Nos).
Supply and fix MCB FP 40 Amps ,50Hz, 415 Volt, with breaking capacity 10 KA all as specified and directed.(TPN DB at Ante room-01 x 3 Squadrons = 03 Nos)
Supply and fix sheet metal enclosure 240 volts with a two pin and earth plug and socket complete with one 20 Amp MCB DP connecting complete all as specified and directed. (Computer room-03,Guestroom -01,barbershop- 01,counselling room-02) Total -07 x 3 Squadrons = 21 Nos.
Supply and fix junction box made out of SMC/FRP with one MCB TPN 25A including all fixing accessories for outdoor units of cassette AC all as directed and as specified. Make:Sintex,Hensel,National.
Material and labour for sub main wiring using 4 runs of single core PVC insulated FR-LS, unsheathed stranded copper conductor cable of size 16.0 Sqmm of voltage rating 1100 Volts drawn in and including rigid non-metallic PVC surface conduit (Medium grade) of dia not less than 25 mm with standard accessories along-with one runs of PVC insulated FR-LS , unsheathed, stranded copper conductor cable of size 16.0 Sqmm (green colour) as earth continuity conductor including cutting of wall/floor if required and making good the disturbed surfaces complete all as specified and directed. (VTPN DB 4 way to 6 way TPN DBs at Squadron office,Motivation hall) Note : (i) Four run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
Material and labour for sub main wiring using 4 runs of single core PVC insulated FR-LS, unsheathed stranded copper conductor cable of size 10 Sqmm of voltage rating 1100 Volts drawn in and including rigid non-metallic PVC surface conduit (Medium grade) of dia not less than 25 mm with standard accessories along-with one runs of PVC insulated FR-LS , unsheathed, stranded copper conductor cable of size 10 Sqmm (green colour) as earth continuity conductor including cutting of wall/floor if required and making good the disturbed surfaces complete all as specified and directed. (VTPN DB 4 way to 4 way TPN DB at Ante Room) Note : (i) Four run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
Material and lablour for sub main wiring using 4 runs of single core PVC insulated FR-LS, unsheathed stranded copper conductor cable of size 4 Sqmm of voltage rating 1100 Volts drawn in and including rigid non-metallic PVC surface conduit (Medium grade) of dia not less than 25 mm with standard accessories along-with one runs of PVC insulated FR-LS , unsheathed, stranded copper conductor cable of size 4 Sqmm (green colour) as earth continuity conductor including cutting of wall/floor if required and making good the disturbed surfaces complete all as specified and directed. (TPN DBs to AC units/FRP box) Note : (i) Four run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
Material and lablour for sub main wiring using 2 runs of single core PVC insulated FR-LS, unsheathed stranded copper conductor cable of size 4 Sqmm of voltage rating 1100 Volts drawn in and including rigid non-metallic PVC surface conduit (Medium grade) of dia not less than 25 mm with standard accessories along-with one runs of PVC insulated FR-LS , unsheathed, stranded copper conductor cable of size 4 Sqmm (green colour) as earth continuity conductor including cutting of wall/floor if required and making good the disturbed surfaces complete all as specified and directed. (VTPN/SPN DBs to AC units) Note : (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
Supply and fix powder coated aluminium snap grid frame work for false ceiling with 605mm x 605mm size, consisting of main Tee of size 23.50mm x 36.50mm x 1.50mm, cross Tee of size 23.50mmx23.50mmx1.50mm and wall angle of size 36.00mm x 25.00mm x 1.50mm of approved make including all necessary cuttings, fixing of aluminium section firmly in position with and including steel hangers 6 mm dia G.I. wire (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60 mm long and expansion hold fasteners 40 mm long in soffit of slab/walls with and including provision of 12mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre 600mm x 600mm size, fixed in ceiling, flat or sloping complete all as specified and directed.
General Note on BOQ: (i) The contractor/tenderer should note that construction by other agency for civil work is already going on at the location of the execution mentioned in the contract. (ii) The tenderer shall make all necessary arrangement and planning to follow sequencing of activities under progress by the civil contractor in order to complete the work as per timeline stipulated in the contract agreement.No delay on account of any such hindrance/interference shall be admitted. (iii) Quoted rates includes cost of making good any damages caused to existing assets. (iv) Cutting of false ceiling & making good any damage caused during execution of work is deemed to be included in the rate quoted. (v) Contractor shall be liable to repair/replace components found damaged if any during DLP even after expiry of Guarantee/Warranty period offered by the AC manufacturer. (vi) Contractor shall visit the site of work before participating the bidding process. (vii) Contractor shall depute one technician to check the functionality of AC system and for frequent check up/periodical maintenance instructed by OEM and as directed by Engineer-in-Charge during defect liability period of this contract.
Shree Ayyappa Engineering (BID ID -3179126)
B5BUILDING SOLUTIONS (BID ID -3179004)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .