Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance T STATE BANJARAWALA DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹27.3 L
EMD Value
₹55,000
Closing Date
13 Feb 2025, 3:00 pmClosed
DGM HQ BRIDCUL
BRIDCUL Opp Govt ITI Niranjanpur Saharanpur Road Dehradun
SITC of 13 Passenger Lift (G Plus 5), 6 Stop MRL Type for Laboratory Block at Doon University Dehradun
2025_BRID3_79770_1
167/BRIDCUL/973/25 Dated 28.01.2025
Open Tender
Electrical Works
Item Rate
365 days
Doon University Dehradun
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
MD - BRIDCUL
₹55,000
BRIDCUL Dehrdun
15 Feb 2025
31 Jan 2025
13 Feb 2025
31 Jan 2025
13 Feb 2025
7 Feb 2025
6 Feb 2025
Amount
13 Passenger, 6 Stop Lift
Supply,Installation,Testing and Commissioning of Electric Traction Passenger Lift • Rated capacity :- 13 Passenger/884Kg • Floors :- Ground to Fifth floor (6 Stops / 6 Landings) • Travel :- 21.6 mtrs to 24 mtrs.Aprox. • Location of Lift Machine:- with Machine Room less • Rated speed :- 1.0 mps VS • Doors type :- COPO/TOPO Doors with frame having clear opening of 900 mm wide x 2000 mm high made from SS 304 grade sheet of 1.5mm, thick in hairline finish for car and all landing doors with SS door architraves/frames • Lift car enclosure made from SS 304 grade sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. • COP with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with/without attendant key switch, OWD with audio-visual alarm, VAS in Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.
LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with CPI, Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port, control panel duly wired with proper size & strength copper wire for power & control circuit, with provision for addition of floor/ control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection • ARD complete with necessary SMF VRLA batteries • Fireman controller having fireman switch at fire Landing, • Lift Machine of Gearless PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.
This includes all necessary accessories like LOP's with UP/DN buttons arrows, indicators, extension of guide rails, shaft wiring with trunking,travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete
Full Collective control system.
The Car and Landing Doors shall have vision panel covered with fire rated laminated glass, having punched Jali as a part of the door panel SS sheet itself.
Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work • Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT.
General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector (Lifts) with submission to the Engineer In Charge.
Warrantee: - Job covers three years onsite warrantee for all the Lift parts with FCAMC as per the maintenance schedule.
If the l ift shaft is greater than the required size of the lift as mentioned in relevant Indian Standard [with Amendments up to date], the provision of extra steel required for erecting supports of guide rails shall be made by the department as a separate item
The Electric power supply of 415 volts, 3 phase 4 wire,50Hz shall be made available up to Lift controller, and as per the provisions laid down in relevant The Electricity Safety Regulations 2010[with Amendments up to date], Indian Standard, relevant Rules, the separate cables for lighting and power & shall be erected through lift shaft only with 2nos distinct earth connections from lift machine & controller
The technical specification of Lift duty motor, control panel, brakes, guide rails, and guide shoes, lift car frame, car, counter weight and suspension, lift safety gear and governor, buffer, lift doors, locking device and contacts, lift wire rope of lifts shall be as per actual requirement of the job.
For building having height of 15 mtr or more, lift shall meet the requirement of fireman lift as per the statutory requirements laid in relevant Indian Standard
SHREE BALAJI ASSOCIATES (BID ID -359643)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .