Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹25.1 LAccepted-AOC | 1 | Accepted-AOC Lowest Bidder | |
| 2 | 2₹25.5 L+₹3,118 (0.12%)Rejected-Finance | 2 | Rejected-Finance Not Lowest Bidder | |
| 3 | 3₹25.6 L+₹11,575 (0.45%)Rejected-Finance | 3 | Rejected-Finance Not Lowest Bidder | |
| 4 | 4₹26.3 L+₹84,305.50 (3.31%)Rejected-Finance | 4 | Rejected-Finance Not Lowest Bidder | |
| 5 | 5₹27.3 L+₹1.8 L (7.08%)Rejected-Finance | 5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹36.5 L
EMD Value
₹73,000
Closing Date
7 Jan 2020, 6:00 pmClosed
Garrison Engineer Kota
Opp Circuit House, Station Road, Kota - 324001
PROVISION OF CERTAIN REVENUE, MINOR AND SPECIAL REPAIR WORKS UNDER AGE B/R I AND AGE E/M AT MILITARY STATION KOTA
2019_MES_307762_1
8412/E8
Open Tender
Miscellaneous Works
Item Rate
243 days
Kota
Class D category a(i)
8 documents required · 8 mandatory
₹500
GE Kota
₹73,000
Yes
24 Jan 2020
19 Dec 2019
9 Jan 2020
19 Dec 2019
7 Jan 2020
2 Jan 2020
20 Dec 2019 - 26 Dec 2019
Amount
Excavation in post holes (or similar holes) Each not exc 0.50 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm, watering and removing surplus soil to a distance of n exc 50m and making good surface in hard/dense soil, complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil, complete all as specified and directed.
Removing excavated materials (soil) not exc 50 m distance and depositing where directed at a level not exc 1.5 m above starting point, complete all as specified and directed.
M&L PCC 1:2:4 type B-2, using 40 mm graded stone aggregate, as in foundation filling, mass concreting etc, complete all as specified and directed.
S&F mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St. 240, complete all as specified and directed.
M&L mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed.
S&F Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, complete all as specified and directed.
M&L hardcore (broken stone) of gauge not exc 63 mm, deposited spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
M&L PCC 1:4:8 type D-2, using 40 mm graded stone aggregate, as in foundation filling, mass concreting etc, complete all as specified and directed.
M&L for 100mm thick PCC 1:2:4 mix, type B2 (Using 40 mm graded stone aggregate) as in floors finishing surfaces fair and even, complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer, complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m deep for foundation etc or for shafts, column footings or for laying cables etc not exc 10 Sqm on plan and getting out in any type of soil, complete all as specified and directed.
Excavation over areas not exc 1.5 m deep and getting out in any type of soil, complete all as specified and directed.
Excavation over areas exc 1.5 m but not exceeding 3.00 m deep and getting out in any type of soil, complete all as specified and directed.
Returning filling in soil including spreading, leveling, watering and well ramming in layers not exc 25 Cm, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing tiles and rubbish off the premises, complete all as specified and directed.
Taking up or down steel tubing 15 mm bore and connections including cleaning for refixing or removal to store, complete all as specified and directed.
Taking up or down steel tubing 20 mm bore and connections including cleaning for refixing or removal to store, complete all as specified and directed.
M&L Glazed ceramic coloured tiles on vertical surfaces 350x 250x7 mm/450X350X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, laid over and including 10 mm thick rendering in CM 1:4, complete all as specified and directed.
M&L for non skid ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
Supply, fixing, laying & testing 15 mm bore galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket, reducing bends, elbows, tee, checknuts, caps, plugs etc. laid in trenches, complete all as specified and directed.
Supply, fixing, laying & testing 20 mm bore galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket, reducing bends, elbows, tee, checknuts, caps, plugs etc. laid in trenches, complete all as specified and directed.
S&F Bib tap cast copper alloy with crutch or butterfly handle screwed for iron pipe or for union, 15mm bore, complete all as specified and directed.
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest incl providing lime concrete bedding and connecting to flusing cistern, complete all as specified and directed.
S&F in repair 10 Ltr vitreous china valveless syphonic action type flushing cistern, low level, coloured with inlet, ball valve, float and handle incl PVC flush pipe of 32 mm dia, fixed to wall, complete all as specified and directed.
S&F in repair vitreous china wash hand basin white with flat back of size 550x400 mm, excluding chain and plug, taps and porcelain stopper but including PTMT waste coupling 32 mm bore and and superior quality PVC waste pipe of 32 mm bore with connector & a pair of cast iron brackets of appropriate size, complete all as specified and directed.
S&F PVC connection, 15 mm size with two PTMT nuts, length of connection 450 mm, complete all as specified and directed. (Make - India Prayag/Polytuf)
M&L PCC 1:5:10 type E-2, using 40 mm graded stone aggregate, as in foundation filling, mass concreting etc, complete all as specified and directed.
M&L brick work with pulverized fuel Ash-lime bricks (old size fly ash bricks), straight or curved on plan exc 6 m mean radius, built in CM 1:6, complete all as specified and directed.
M&L for rendering 15 mm thick on other than fair faces of brick work or stone masonry surface in cement mortar 1:6, surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, old size, straight or curved on plan to any radius in half brick walls built in cement mortar 1:4 complete all as specified and directed.
M&L PCC 1:4:8, type D-2 using 40 mm graded stone aggregate, as in concrete bed to drain pipes including packing under and haunching against the sides of 150 mm dia pipe, after they are laid and tested, complete all as specified and directed.
M&L 150 mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars, complete all as specified and directed.
M/L for 50mm thick rough dressed stone slabs for manhole covers n.exc 2 mtr in length, punched dressed on face and along exposed edges, self faced on other side and sets and pointed in cement mortar 1:4 complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) 75 mm thick as in sub base, finishing the surface even & rough to receive topping layer, complete all as specified and directed.
M&L for 25 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in flooring finished even and rough, complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate), 75 mm thick as in plinth protection/Path/PCC paving etc including finishing the surface even & smooth without using extra cement, with and including all necessary formwork to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm wide joints throughout the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three parts of fine sand by weight), complete all as specified & directed.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing, complete all as specified and directed.
S&F 150 mm aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
S&F 100 mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, complete all as specified and directed.
S&F aluminium handles, cast type, anodised 150 mm size, fixed with screws, complete all as specified and directed.
S&F steel windows with top hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, including one shop coat of zinc chromate primer, complete all as specified and directed.
S&F mild steel framed work as in grills, grating etc. with end of bars shouldered and/or riveted, or forged into spikes: framed guard bars: barred iron doors: ladders: frame balusters: walk ways: railing: frame work of water tanks and similar works conforming to Fe-290 Grade-E-165, complete all as specified and directed.
M&L walling of random rubble, uncoursed well bonded, bedded and solidly hearted, built in Cement Mortar 1:6, complete all as specified and directed.
M&L walling of random rubble, uncoursed well bonded, bedded and solidly hearted, built in Cement Mortar 1:4, complete all as specified and directed.
M&L Walling of random rubble, uncoursed, well bonded, laid dry in retaining walls, abutments and similar work, complete all as specified and directed.
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses, with maximum depression on face from straight edge held against the dressed surface not exceeding 20 mm; to block in course masonry (Lime or sand stone), complete all as specified and directed.
M&L for rendering 10mm thick on ceiling in cement mortar 1:4 including finishing the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 15 mm thick rendering on other than fair faces of brick work or stone masonry surfaces in two layers, consisting of 10 mm thick in CM 1:6 and over that 5 mm thick in Cm 1:4 using water proofing compound as per manufacturer's instruction's, finishing surfaces even and smooth without using extra cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
Supply only approved integral water proofing compound, complete all as specified and directed.
M&L for applying three coats of white wash on walls including preparation of new or previously untreated surfaces, complete all as specified and directed.
M&L for applying three coats of white wash on ceiling including preparation of new or previously untreated surfaces, complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of primer on newly plastered surfaces of walls including preparation of surfaces, complete all as specified and directed.
S&F in position rotational moulded polyethylene water storage tanks 500 lts capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I and as directed.
S&F 20 mm dia ball brass valve, high pressure with polythene float and fly nut, screwed down for iron pipe, complete all as specified and directed.
S&F 15 mm dia stop valve, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for union complete all as specified and directed.
S&F fancy type pillar taps, cast copper alloy, with capston heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and flynuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed.
S&F 10 Ltr vitreous china valveless syphonic action type flushing cistern, low level, coloured with inlet, ball valve, float and handle incl PVC flush pipe of 32 mm dia, fixed to wall, complete all as specified and directed.
S&F vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest incl providing lime concrete bedding and connecting to flusing cistern, complete all as specified and directed.
S&F sand cast iron soil, waste and vent pipe 75 mm bore in any length with or without ears with cement joints laid in trenches or in floor, complete all as specified and directed.
S&F 75 mm bore CI bend(any radius), diminishing pieces or tapers (large bore measured) with oval access door, complete all as specified and directed.
S&F CI branch pieces 100 mm dia single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches, complete all as specified and directed.
S&F vitreous china wash hand basin white with flat back of size 550x400 mm, excluding chain and plug, taps and porcelain stopper but including PTMT waste coupling 32 mm bore and and superior quality PVC waste pipe of 32 mm bore with connector & a pair of cast iron brackets of appropriate size, complete all as specified and directed.
S&F vitreous china bowl urinal flat back of size 465x355x265 mm, white with grating and union for discharge pipe, including providing and fixing plugs, bedding urinal against wall in CM 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back with white cement, complete all as specified and directed.
S&F shower rose, chromium plated brass, fancy type, 125 mm size with swivel joint, screwed to iron pipe or for union of 15 mm dia, complete all as specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed.
Formwork (rough finished surfaces) to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar works, not exc 200 mm thick complete all as specified and directed.
M&L for RCC 1:1.5:3 type A-1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns, in floors, roofs, landing balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.
M&L for 150 mm dia salt glazed stoneware drain pipes, laid in trenches and jointed in cement sand slurry in 1:1, complete all as specified and directed.
S&F salt glazed stone ware gully traps, square or round mouthed, type 'P', size 150x150 mm, with and including bedding in PCC 1:5:10 type E1 using 20 mm graded stone aggregate, complete all as specified and directed.
M&L cutting existing manholes for connecting new drain (for 150 mm bore pipe), making good to pipe and rendering, cutting out existing benching for forming branch channel (half round or 3/4 section) in cement concrete 1:2:4 type B-1 or smooth finishing, complete all as specified and directed.
Taking down cement plaster of any description and thickness on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and and in any position not otherwise specifically provided for and removing rubbish from premises, complete all as specified and directed.
M&L for joint free non skid ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for joint free non skid ceramic coloured tiles, 7 to 8mm thick (square/rectangular), laid in skirting/dado etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 10 mm thick CM 1:4 backing, complete all as specified and directed.
Dismantling water storage tank of any description of capacity exc. 250 ltr but n.exc. 500 ltr, complete all as specified and directed.
Dismantling water storage tank of any description of capacity exc. 500 ltr but n.exc. 1000 ltr, complete all as specified and directed.
S&F in position rotational moulded polyethylene water storage tanks 1000 lts capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I and as directed.
Taking down Chowkats or frames with shutter (without taking off shutters from the frame) n. exc. 1.50 Sqm each, complete all as specified and directed.
Refixing old steel tubing and connections in new or old position (walls, ceiling, floors, etc.) for 15 mm dia pipes with and including all new fittings complete all as specified and directed.
Refixing old steel tubing and connections in new or old position (walls, ceiling, floors, etc.) for 20 mm dia pipes with and including all new fittings complete all as specified and directed.
Dismantling cast iron or reinforced concrete drain pipes 100 mm bore, jointed in CM and taking out from trenches if required, complete all as specified and directed.
Dismantling cast iron or reinforced concrete drain pipes 75 mm bore, jointed in CM and taking out from trenches if required, complete all as specified and directed.
S&F PVC (SWR) pipe 75 mm bore, single socketed, in any length with rubber ring joints and laid in trenches/floor, complete all as specified and directed.
S&F PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints and laid in trenches/floor, complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block any shape and size made with grey cement and pigment, confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade, laid over and including 25 mm thick sand cushion, complete all as specified and directed.
M&L precast (factory casted) cement concrete kerb stone casted in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate with plain or interlocking joints (as directed), making groove in ground of desired dimension, placing in position and set and jointed in CM 1:4, making good disturbed surface of ground, complete all as specified and directed.
S&F grating doom of 140 mm dia, made of PTMT with or without waste hole, minimum weight 40 gms, complete all as specified and directed.
S&F in repair vitreous china bowl urinal flat back of size 465x355x265 mm, white with grating and union for discharge pipe, including providing and fixing plugs, bedding urinal against wall in CM 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back with white cement, complete all as specified and directed.
S&F in repairs 'D' type towel rail 60 cm long, stainless steel, fancy type, 20 mm dia complete fixed with steel screws complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work & precast concrete articles complete all as specified and directed.
M&L for machine cut kota stone slab as in flooring 17 to 22 mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing, laid over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L Providing cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
S&F stainless steel utensil plate rack of size 600x600x250 mm, made of 24 gauge thick stainless steel sheet and fixed in position, design and pattern as approved by the GE, complete all as specified and directed. (Cat part No P-310 of make Prayag or equivalent in Nirali/Bluestar/Parryware)
M&L granite slab 18-20 mm thick, table rubbed and polished, machine cut and fixed in any position over and including 10 mm thick CM backing in CM 1:4, jointed with grey cement slurry and pointed in white cement with pigment to match the surface, including cutting, polishing, bull nosing to exposed outer edges, complete all as specified and directed.
S&F Anodised aluminium snap grid frame work for false ceiling, size of grid 605x605 mm, including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, complete all as specified and directed.
M&L for 'E' board Classic ceiling, 8 mm thick fixed to snap grid frame work and applying two coats of distemper oil emulsion on ceiling boards, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
Disconnecting existing water tank of capacity exc. 500 ltr but not exc. 1000 ltr, setting aside (or lowering of required) for repairs to roofs etc. and hoisting if required reconnecting and refixing in position on roof, complete all as specified and directed.
M&L for PCC 1:2:4 mix type B-0 (Using 12.5 mm graded stone agg) for filling in pressed steel frames, roof padding, leveling course to receive floor finishes etc complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of RCC roof slab in CM 1:4 duly mixed with liquid water proofing compound, finishing surfaces even and smooth without using extra cement, complete all as specified and directed. (WPC shall be measured and paid separately)
Supply only liquid water proofing compound Dr Fixit LW+ or equivalent as approved by the GE, complete all as specified and directed.
M&L for cleaning of roof slab including picking, sweeping clean and washing down with water to remove dust, dirt etc and Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over cold applied bituminous primer conforming to IS 3384 @ of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions complete all as directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, [email protected] Kg/Sqm over a coat of cold applied bituminous primer conforming to IS:3384 @ 0.40 Kg/Sqm.
Item 106.00 Contd..... (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm (minimum) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimney/other vertical surfaces and polymeric membrane inserted in groove and sealed with paving bitumen. (v) Above aspects are deemed to be included in quoted rate.
S&F welded steel wire fabric supplied and fixed complete to wood or steel members, weight per Sqm not exceeding 4.00 kg, complete all as specified and directed.
Hacking out old broken glass (any thickness size, quality or description) from wooden frame/steel frame, glazing with putty or fixed with beads complete all as specified and directed.
S&F sheet glass 3mm thick ordinary quality and glazing with oil putty etc in squares n.exe 0.50 Sqm in each pane, complete all as specified and directed.
M&L for preparing new previously untreated plastered surfaces of walls and applying two coats of modified exterior acrylic emulsion paint over a coat of primer, complete all as specified and directed. (Make: Asian paints - Apex Ultima, ICI Dulux - Weather Shield Max, Berger - Weather Coat Long Life, Acro Paints - Acroguard 3X)
M&L for complete removal of existing treatment previously treated plastered surfaces of walls and applying two coats of modified exterior acrylic emulsion paint over a coat of primer, complete all as specified and directed. (Make: Asian paints - Apex Ultima, ICI Dulux - Weather Shield Max, Berger - Weather Coat Long Life, Acro Paints - Acroguard 3X)
S&F gun metal globe or gate valve of size 20 mm dia with iron wheel head screwed both ends and for iron pipe & fixed complete all as specified and directed. .
S&F in repair Bib tap cast copper alloy with crutch or butterfly handle screwed for iron pipe or for union, 15mm bore, complete all as specified and directed.
S&F in repair PVC connection, 15 mm size with two PTMT nuts, length of connection 450 mm, complete all as specified and directed. (Make - India Prayag/Polytuf)
S&F in repair 15 mm dia stop valve, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for union complete all as specified and directed.
S&F in repair fancy type pillar taps, cast copper alloy, with capston heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and flynuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed.
S&F in repair grating doom of 140 mm dia, made of PTMT with or without waste hole, minimum weight 40 gms, complete all as specified and directed.
M&L mild steel TMT bars, 5 to 10 mm dia as in stirrups/spacers and binders etc, cut to length, bent to shape required including cranking, bending spirally for hooping for column, hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
S&F PVC (SWR) bend 110 mm bore, any radius, incl jointing to waste pipe with solvent cement, complete all as required and as directed.
S&F PVC (SWR) 110 mm bore single Junction 'T', equal or unequal, incl jointing to waste pipe with solvent cement, complete all as specified and directed.
S&F PVC (SWR) bend 75 mm bore, any radius, incl jointing to waste pipe with solvent cement, complete all as required and as directed.
S&F PVC (SWR) 75 mm bore single Junction 'T', equal or unequal, incl jointing to waste pipe with solvent cement, complete all as specified and directed.
Formwork (for fair finished surfaces) to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., complete all as specified and directed.
Formwork (rough finished surfaces) to edges of concrete exc 10 Cm thick and not exc 20 Cm thick as in slabs, bands, cills, flooring etc for rough finished surfaces complete all as specified and directed.
M&L for RCC 1:1.5:3 type A-1 (using 20 mm graded stone aggregate) as in beams, cantilevers, bressumers, lintels etc over 1.5 m in span, complete all as specified and directed.
Supplying and installing reverse osmosis water purifier having balanced minerals for human consumption with minimum of five stages purification process i.e. sedimentation filter, pre filter, activated carbon block, RO membrane and UF membrane having purified water discharge capacity of not less than 50 Litres per hour with fully automatic operation, electrically operated, 230 Volts AC, single phase, outlet of purifier connected to storage tank of water cooler with suitable PVC pipes and connectors etc to provide water on demand, complete all as specified and directed. (Make - Kent/Aqua Guard/ Zero B)
S & F of BEE 5 star rated Electric Water heater storage type (Geyser), Glassline coated tank for protection against corrosion for longer life of heating element With 4-in-1 multipurpose valve for safety, temperature indicator dial, fire retardant cable Neon indicators for 'Power on' & 'heating' functions supplied and installed complete capacity 25 litres storage water heater after grouting 4 Nos new bolts of required size at new/same distance in wall and tightening with nuts & washers incl extending/modifying/altering 15mm bore GI pipe line with tee, union, socket, nipple etc suitable for 15mm bore GI pipe as and where required complete connecting with chromium plated pipe (for hot water supply) and PVC flexible pipe (for cold water supply) fixed with brass check nuts & PVC flexible pipe (for cold water supply) fixed with brass check nuts & PVC washers at both ends, complete all as specified & directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for reuse or for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Dismantling unserviceable main switch/DBs incl wooden board and deposit to MES store yard including making good disturbed surface of wall complete all as specified and directed.
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed surfaces to match with the existing surface, complete all as specified and directed.
M & L for point wiring with PVC insulated unsheathed (FRLS) stranded copper conductor of size 1.5 sqmm (nominal cross sectional area) single core cable of 1100 volts grade in and including rigid non metallic PVC conduit 20 mm or higher size medium grade ISI marked complete with all PVC Conduit provided in concealed manner as directed at site including new pressed mild steel terminal sunken box made out of 1.2 mm thick sheet covered with & including new 3 mm thick plastic laminated hard glossy surface sheet top cover concealed in wall with brass screws & brass cup washers including continuous earth wire of green colour PVC insulated unsheathed (FRLS) 1100 volts grade single core cable, 1.50 sqmm stranded copper conductor, connected to all fittings, sunk boxes, earth pointing sockets, connected to common earth, earth dolly complete all as specified & directed for the following: - One light /fan /bell /exhaust fan point controlled by one, one way 5/6 switch or bell push one way 5/6 Amp. Note: Rate for wall cutting for switch/terminal boxes and making good disturbed surfaces to match with the adjoining surface shall be deemed included in the unit rate.
M&L for Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less then 20 mm width fixed on surface including making good disturbed, complete surface all as specified and directed for the following: - One light/ceiling fan/exhaust fan/bell buzzer point controlled by one, one way switch of 5/6 Amps.
One 3 pin 5 Amp socket outlet point on the same board with other switches.
One 3 pin 5 amps socket outlet point on independent board.
One light point controlled by two, 2-way switches of 5/6 amps.
M&L Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 2.5 Sqmm, with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable FRLS of size 2.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less than 20 mm width fixed on surface for one socket outlet 15 amp on independent board including making good disturbed surfaces, complete all as directed and specified.
S&F switch piano flush type 5/6 Amps, 230 volts, single pole, one way, ISI marked, complete all as specified & directed.
S&F switch piano flush type 5/6 Amps, 230 volts, single pole, two way, ISI marked, complete all as specified & directed.
Supply and fixing switch socket combination, 5/6 and 15/16 Amps, 230 volt, multi pin, flush type universal, complete all as specified and directed.
Supply and fixing switch socket combination, 5/6 Amps, 230 volt, multi pin, flush type universal, complete all as specified and directed.
Supply and fixing socket outlet, 5/6 Amps, 230 volt, multi pin, flush type universal, complete all as specified and directed.
S&F stepped type electronic fan regulator, flush type, 230 volts AC, single pole, humming free, fixed on the existing phenolic laminated sheet, complete all as specified and directed.
S&F ceiling rose surface type PVC/Polycarbonate isolated body, 65x 20mm, 3 terminals, complete all as specified & directed.
S&F switch bell push, 5/6 Amps, 230 volts, single pole, one way, ISI marked, complete all as specified & directed.
S&F bell electronic, ding dong type, 230 volts, single pole, ISI marked, complete all as specified & directed.
S&F LED Tube light fittings, batten type with bipin holders, powder coated steel with retrofit 20 watt LED tube, internally prewired, complete all as specified and directed.
S&F LED light fittings of size 600x600 mm, mirror optic type suitable for fixing in ceiling, 20 watt, internally prewired, complete all as specified and directed.
S&F PVC/polycarbonate lamp holder, angular/batten type with back plate, complete all as specified & directed.
S&F MCB, 6 to 32 Amps, Single Pole, 240 Volt, 10 KA 'B' series including all accessories, complete all as specified and directed.
S&F MCB, 6 to 32 Amps, Single Pole & Neutral, 240 Volt, 10 KA 'B' series including all accessories, complete all as specified and directed.
S&F MCB, 63 Amps, Triple Pole & Neutral, 415 Volt, 10 KA 'B' series including all accessories, complete all as specified and directed.
M&L for MCB DB made of sheet steel phosphatised, powder painted with bus bar 200 A, neutral link, earth bar and Din rail, 415 Volts TPN with 4 ways, Double door, complete all as specified and directed.
M&L for MCB DB made of sheet steel phosphatised, powder painted with bus bar 200 A, neutral link, earth bar and Din rail, 415 Volts TPN with 8 ways, Double door, complete all as specified and directed.
M&L for MCB DB made of sheet steel phosphatised, powder painted with bus bar 200 A, neutral link, earth bar and Din rail, 240 Volts SPN with 8 ways, Double door, complete all as specified and directed.
M&L for MCB DB made of sheet steel phosphatised, powder painted with bus bar 200 A, neutral link, earth bar and Din rail, 240 Volts SPN with 12 ways, Double door, complete all as specified and directed. Note for items of MCB DB's: - (1) The unit rate includes for cutting the brick walls to accommodate DB to make flush to wall. (2) The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface.
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed FRLS multi-stranded copper conductor cable of size 2.5 Sqmm LT, 1100 volts grade, drawn through and including minimum 20 mm wide PVC non metallic surface casing/capping with all accessories and fittings and one run of 2.5 sqmm single core multi-stranded FRLS copper conductor cable green colour as earth continuity conductor complete all as specified & as directed.
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed FRLS multi-stranded copper conductor cable of size 4 Sqmm LT, 1100 volts grade, drawn through and including minimum 20 mm wide PVC non metallic surface casing/capping with all accessories and fittings and one run of 4 sqmm single core multi-stranded FRLS copper conductor cable green colour as earth continuity conductor complete all as specified & as directed.
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed FRLS multi-stranded copper conductor cable of size 6 Sqmm LT, 1100 volts grade, drawn through and including minimum 20 mm wide PVC non metallic surface casing/capping with all accessories and fittings and one run of 6 sqmm single core multi-stranded FRLS copper conductor cable green colour as earth continuity conductor complete all as specified & as directed. NOTES for sub main wiring:- (i) Two runs of cable one run of earth wire and one run of PVC non metallic casing/capping shall be measured as one run length. Cost of cable required for connection to DBs shall deemed to be included and shall not be measured separately. Earth wire shall run inside the PVC casing/capping.
S&F LED security light fitting, 36 watt, pressure die cast aluminium housing with IP 66 deg of protection, complete with 1.20 m long street light swan neck shaped bracket made of 40 mm bore GI light grade tubing, fixed on pole/walls including necessary FI clamps, nuts, bolts, washers etc, complete all as specified and directed. Make: Philips/Surya/Bajaj.
Disconnecting and taking down carefully ceiling fan/exhaust fan and refixing the same after rewiring work, complete all as specified and directed.
M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized earth lead strip of size 25mm x 4 mm by means of bolts, buts, check nuts and washers of galvanized iron on steel including 40 mm dia light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm dia, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinforced with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including GI strip of size 25 mm x 3 mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 3 and complete all as specified and directed. Notes: - (a) Irrespective of whatever is shown in plate No 5 of SSR, earth pit shall be casted in PCC (1:3:6) type C-1 and precast cover of RCC (1:2:4) type B-1 with suitable handle. (b) Item includes the cost of GI pipe for protection of earth wire/strip and earth strip upto 7.5 m. Any variation below or above shall be measured and paid for separately under relevant item of this Sch ‘A’.
Supply, Laying, jointing and testing of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable, heavy duty, with 16 Sqmm, 2 core aluminium conductor, 1100 Volts grade, complete all as specified and directed.
M&L for dry and fine river sand free from sharp material as in cushioning to cable in trenches for cable protection including necessary punning and consolidation as required complete all as specified and as directed. (Depth of sand shall be measured after punning).
Supplying and laying pulverized fuel Ash-lime bricks (Fly ash bricks - non modular size), laid flat adjoining each other as in protection to UG cables, complete all as specified and directed.
S&F PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 100x100 mm and 50 mm deep, complete all as specified and directed.
All as per item 162 above but of size 175x100 mm and 50 mm deep, complete all as specified and directed.
All as per item 162 above but of size 200x150 mm and 50 mm deep, complete all as specified and directed.
All as per item 162 above but of size 250x200 mm and 50 mm deep, complete all as specified and directed.
S&F Tubes "light grade" galvanised iron of 40 mm bore, laid under roads/drain, fixed to poles, walls, with flat iron clamps, bolts/ nuts/ washers etc, complete all as specified and directed.
S.S Enterprises
ANNAPURNA ENTERPRISES
ONKAR ENGINEERS
L P Singh and Co.
M/s Prem Associates
TARKESHWAR DASS CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .