Loading…
Loading…
Tender Value
₹3.6 L
EMD Value
₹10,000
Closing Date
14 May 2026, 6:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
Municipal Commissionar, AMC
Rate Contract for SITC of Different Capacity UPS(Uninterrupted Power Supply) System in C. H. Nagri Muni. Eye Hospital & Other Hospital/College/Hostel Buildings of AMC-MET. (Within Limit of Amount Rs.10.00 Lacs)
300481
2026
Open
Miscellaneous Works
Ahmedabad
3 documents required · 2 mandatory · 1 optional
₹900
Municipal commissioner, Ahmedabad
₹10,000
2 May 2026
2 May 2026
2 May 2026
14 May 2026
2 May 2026
(Technical Bid only) of Tender
Office, Mezzanine Floor, “B”-Block,
in Physical form Sardar Patel Bhavan, Danapith,
Ahmedabad-380001.
4 Tender Vol-I (Technical Bid on 15/05/2026, 04:05 pm onwards
only) Opening Date, Time and Online Opening:- At the Office of
Place Additional Chief Engineer(Electrical),
Light Department, 5th Floor, “C”-Block,
Sardar Patel Bhavan, Danapith,
Ahmedabad-380001.
Physical Opening:-At the Office of Tender
Officer, Central Record Office, Mezzanine
Floor, “B”-Block, Sardar Patel Bhavan,
Danapith, Ahmedabad - 380001 or at
the above said office.
MUNICIPAL COMMISSIONER
Ahmedabad Municipal Corporation
Sardar Patel Bhavan,Danapith
VOL.-II (FOR REFERANCE ONLY)
Rate Contract for SITC of Different Capacity UPS(Uninterrupted
Power Supply) System in C. H. Nagri Muni. Eye Hospital & Other
Hospital/College/Hostel Buildings of AMC-MET.
(Within Limit of Amount Rs.10.00 Lacs)
Item Description Unit Qty Unit (Without
PART (A) - SITC
Supplying and erecting approved
make online Un-interruptible
Power Supply system comprising
flat cum-boost charger with IGBT
base rectifier & Inverter & sealed
maintenance free SMF batteries.
The charger having operating
capacity for input 160-270V AC &
inverter having output 230V,50
1.01 Hz Ac with 0.8 load power factor Ea. 1
with battery, over/under voltage
output with over load & short
circuit protection equipment. The
system housed in CRC sheet duly
powder coated paint with following
power backup.with MS painted
batteries stand, 10% Overload
capacity for momentary load.
(A) 1 KVA with 1Hr Backup
Same as Above for -
(B) 2KVA with 1Hr Backup
Same as Above for -
(C) 3 KVA with 1Hr Backup
Same as Above for -
(D) 5 KVA with 1Hr Backup
Providing Batteries With Standard
. IEC61056-3 OR JIS C
Battery type - Maintenance Free
Or Minimum Maintenance Lead
Acid, Battery @ C20 Rating -12V,
Cut Off Voltage( at 25 deg C-
10.2V, Float Charging Voltage-
13.5 volts per module @ 27 deg C,
Voltage ripple allowable - <2% of
the RMS value, AH Efficiency-
Above 95%, Operating
Temperature range of Battery- -20
deg C to + 60 deg C, Date of
manufacturing - The date of
Manufacturing shall not be more
than 6 Months older than the date
Same as Above for –
Same as Above for –
Same as Above for –
Same as Above for –T
Same as Above for –
Same as Above for –
Same as Above for –
Same as Above for –
Same as Above for –
Point wiring for Light / Bell with
2-1.5 sq.mm & earth wire of
sq.mm (Green) both are of ISI
marked 1.1 KV grade FRLS PVC
insulated multi strand copper
wires up to 10 mtr length , in
below type of pipe erected with 6A
Modular type switch / bell push &
accessories and earth continuity
of following type, erected on PVC /
Metallic/Wooden box, single
mounting base frame covered
with textured/metallic/white front
plate modules erected on / in
wall / ceiling as per pipe erected,
with necessary Lamp
holder/ceiling rose /
H.D.Connector as directed.(e) in
existing pipe erected flushed on
wall/ceiling complete Cat. III
Point wiring for Individual Plug
with & earth wire of 1.5 sq.mm
(Green) both are of ISI marked
KV grade FRLS PVC insulated
multi strand copper wires up to
10 mtr length, in below type of
pipe erected complete with
Modular type switch & 5 pin Plug
erected on PVC / Metallic/Wooden
4.01 box covered with appropriate front Pt. 1
plate modules erected on / in wall
/ ceiling as per pipe erected with
following type of accessories.
[I] For 6A Plug and 6 a switch
with 2-1.5 sq.mm Cu. Wire from
nearby switchboard/mcb db
(e) in existing pipe erected flushed
on wall/ceiling complete Cat. III
Same as Above for -
[II] For 16A Plug and 16 amp
switch with 2-2.5 sq.mm Cu.
Wire from mcb db board.
(e) in existing pipe erected flushed
on wall/ceiling complete Cat. III
Point wiring for on board Looped
Plug with 6A Modular type switch
& 5 pin socket erected on PVC /
Metallic/Wooden box, single
5.00 mounting base frame covered with Pt. 1
textured / metallic/white front
plate modules erected on / in
wall / ceiling with following type
accessories Cat.III
Providing and erecting ISI mark
Medium class RIGID PVC PIPES of
following size complete to be
erected on/in wall or ceiling
erected with necessary PVC
fittings & Junction boxes fixed
with adhesive solution & Clamps
with following dia of pipes, in
approved manner as directed
6.02 Same as Above for -(b) 25 mm Mtr. 1
Same as Above for –
Same as Above for –
Supplying and laying UPVC cable
trunking system comprising
unplasticised polyvinyl, chloride
rigid material with ignition free
and flame proof confirming BS
7.01 with necessary end caps Internal Mtr. 1
and external bend, flat bends,
coupler, tee etc..All necessary
accessories and measuring of
following sizes
(1) 75 mm x 50 mm trunking
Same as Above for –
(2) 100 mm x 50 mm trunking
Same as Above for –
(3) 50 mm x 50 mm trunking
Same as Above for –
(4)100 mm x 50 mm trunking with
TWIN compartment With clip in
Providing and erecting Mains with
1.1 KV grade FRLS PVC insulated
ISI marked stranded Copper
conductor wire in following type of
pipe to be erected concealed in
/flushed on wall/ceiling, with
8.01 sq. mm copper conductor FRLS Mtr. 1
PVC insulated stranded wire of
green colour for earth continuity
of following size
(A) With medium class Rigid PVC
pipe and accessories
(a) 2 wire 1.5 sq. mm
Same as Above for –
(b) 2 wire 2.5 sq. mm
Same as Above for –
(c) 3 wire 1.5 sq. mm
Same as Above for –
(d) 3 wire 2.5 sq. mm
Same as Above for –
(e) 4 wire 1.5 sq. mm
Same as Above for –
(f) 4 wire 2.5 sq. mm
Providing and erecting Mains with
1.1 KV grade FRLS PVC insulated
ISI marked stranded Copper
conductor wire in following type of
9.01 pipe to be erected in / on wall / Mtr. 1
ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated
stranded wire of green colour for
earth continuity of following size
(E) in existing pipe
(a) 2 wire 4 sq. mm
Same as Above for –
(b) 2 wire 6 sq. mm
Providing and erecting Mains with
ISI marked, 1.5KV grade
electrolyte multi stranded,
annealed copper conductor with
heat resistant PVC insulated
conforms to IS 694, IEC -
erected in existing pipe of
following size (Specifically for
control panel, relays, power
switchgears, motor starters &
control wiring) with required size
of copper lugs, nuts and bolts if
(e) One wire 6.00 sq. mm
Same as Above for –
(f) One wire 10.00 sq. mm
Same as Above for –
(g) One wire 16.00 sq. mm
Providing and erecting
XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Copper
conductor for 1.1 KV. to be laid
on wall with necessary clamps or
in existing trench / pipe at road
crossing or floor of following size
(A) 3 1/2 core 25 Sq. mm (10 Sq.
Same as Above for –
11.02 (B) 3 1/2 core 35 Sq. mm (16 Sq. Mtr. 1
SITC of 14.2 mm dia 3 mtr long
Earth electrode of High tensile
steel electrode with 250 micron
copper bonding & 1 bag of Carbon
fill Based environment friendly
backfill tested as per IEC 62561-7
in NABL accredited Laboratory Per
and suitable stainless Steel double Set
sided clamp. Eco Friendly rust
proof heavy duty weather proof
Polyethylene Earth Pit Chamber
with following dimensions :254
mm dia (top), 330 mm dia
(bottom) & 260 mm (height).
providing and erecting Miniature
circuit breaker single pole 6A to
25A suitable to operate on 240 V
13.00 A.C. system and having breaking Ea. 1
capacity 10 KA to be erected in
existing box. confirming to IS
8828/1996 with ISI Mark Cat.III
Providing & erecting 240 V MCB
double pole switch for motor &
inductive load (C Curve) having
14.01 10 KA breaking capacity & Ea. 1
confirms to IS : 8828 in existing
box having following capacity
(A) 6 to 32 Amp. Cat.III
Same as Above for –
(B) 40 Amp. Cat.III
Providing & erecting 415 V MCB
Four Pole for Motor & Inductive
Load (C Curve) having 10KA
15.01 breaking capacity & confirms to IS Ea. 1
:8828 in existing box having
following capacity
(a) 6 to 32 Amp. Cat.III
Same as Above for –
(b)40 Amp. Cat.III
Same as Above for –
(c)63 Amp. Cat.III
Providing and erecting Sheet Steel
powder coated MCB distribution
board - flush / surface mounted
fitted with busbar, neutral link,
earth bar and DIN rail, Conforms
3 without MCB to house
16.01 appropriate nos. of MCBs.(The Ea. 1
DBs should be used of same
company of MCB to be used)
(A) single phase incoming and
horizontal single phase outgoing
(b) sheet steel double door (IP-43)
Same as Above for –
Same as Above for –
Same as Above for –
Providing and erecting Sheet Steel
powder coated MCB distribution
board - flush / surface mounted
fitted with busbar, neutral link,
earth bar and DIN rail, Conforms
3 without MCB to house
appropriate nos. of MCBs.(The
16.05 DBs should be used of same Ea. 1
company of MCB to be used)
(B) three phase incoming and
single phase horizontal type
outgoing Per phase isolation type
(b) sheet steel double door
Same as Above for –
Same as Above for –
Same as Above for –
Providing and erecting Approved
make Four pole moulded case
circuit breaker having breaking
capacity ICU of 25 KA. at
V,having normal current rating up
to 25 A to 100A. with Fixed
17.00 thermal & magnetic release Ea. 1
suitable to work on A.C. supply
c/s. with all internal connections,
spreader tinned copper &
complete erected in existing
G.M.S. housing. ICS=100% of ICU
Providing and erecting Approved
make Four pole moulded case
circuit breaker having breaking
capacity ICU of 35 KA. at 415 V.
having normal current rating
125A. with Fixed thermal &
18.00 magnetic release suitable to work Ea. 1
on A.C.supply 50 c/s. with all
internal connections, spreader
tinned copper & complete erected
in existing 16 G.M.S. housing.
ICS=100% of ICU only
Providing, erecting, fabricating the
M.S. structure as per requirement
on site incorporating proper size of
M.S. angles, square, round, flats,
bars, channels, sections complete
19.00 with cutting, welding, grinding & Kg. 1
finishing duly painted with one
coat of red oxide with erection on
site as per direction of engineer in
charge with necessary grouting,
cementing, plastering & finishing
TOTAL AMOUNT OF PART (A) IN Rs.
TOTAL AMOUNT OF PART (A) IN Rs.
PART (B) - BUYBACK RATE FOR
20.01 (A) 1 KVA with 1Hr Backup Ea. 1
20.02 (B) 2KVA with 1Hr Backup Ea. 1
20.03 (C) 3 KVA with 1Hr Backup Ea. 1
20.04 (D) 5 KVA with 1Hr Backup Ea. 1
20.05 [E] 6 KVA with 1Hr Backup Ea. 1
20.06 [G] 7.5 KVA with 1Hr Backup Ea. 1
20.07 [H} 10 KVA with 1Hr Backup Ea. 1
TOTAL AMOUNT OF PART (B) IN Rs.
TOTAL AMOUNT OF PART (B) IN Rs.
1 Amount of Part (A) in Rs.
2 Amount of Part (B) in Rs.
Total Estimted Amount(Without GST) PART
(A) - PART (B) in Rs.
4 GST @ 18% in Rs.
Total Estimted Amount(With GST) PART (A)
- PART (B) in Rs.
I/We am/are willing to carry out work at____________%above or
___________% Below the estimated cost mentioned above.
NOTE:-(1) The Quoted Rate shall be inclusive of all taxes.
Signature of the Tenderer Addl. Chief Engineer
Name: (Electrical)
Company’s seal: AMC
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
VOL - I Technical Bid-3.pdf
VOL - II Price Bid-3.pdf
Download all tender documents and submit your bid