| 1 | L1₹37.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹42.3 L+₹1.6 L (3.91%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹45.4 L+₹4.7 L (11.5%)Rejected-Finance 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L3 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | Raj Enterprise L3 | M/S GN ENTERPRISE L1 | M/S RUSTAM ALI L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply and fix in replacement the starter submersible pump motor starter fully automatic star delta operated enclosed in sheet enclosure type for submersible pump motor AC-3 rating 50 HZ 3 phase of capacity 15 HP with single phase preventer complete including making necessary electrical connections all as specified and directed. Make- L&T /Schneider/Havells
Note:these starter should be accomodate in existing panel and should fixed properly as previous one rating and space. | 2 | Each | 18,500 ₹37,000 | 16,500 ₹33,000 Lowest | 18,500 ₹37,000 |
| 2.00 | Supply and fix in replacement submersible pump motor starter fully automatic star delta operated enclosed in sheet enclosure type for submersible pump motor AC-3 rating 50 HZ 3 phase of capacity 20HP complete including making necessary electrical connections all as specified and directed. Make- L&T /Schneider/Havells.
Note:these starter should be accomodate in existing panel and should fixed properly as previous one rating and space. | 3 | Each | 21,500 ₹64,500 | 17,000 ₹51,000 Lowest | 20,500 ₹61,500 |
| 3.00 | Supply and fix in replacement centrifugal /monoblock pump motor starter fully automatic star delta operated enclosed in sheet enclosure type for submersible pump motor of capacity 10-15 HP, AC-3 rating 50 HZ 3 phase complete all as specified and directed. Make: Havells/schneider/L&T
Note:these starter should be accomodate in existing panel and should fixed properly as previous one rating and space. | 2 | Each | 13,000 ₹26,000 Lowest | 15,000 ₹30,000 | 16,800 ₹33,600 |
| 4.00 | M&L for construction for water level indicator of existing size made out of MS Sheet of 1.6mm thick complete including painting with super enamelled paint of white colour duly marked the water levels in red colour showing the levels of water inside the overhead tank including aero of existing size painted with red colour and fixed at the height of approx 50 feet testing complete all as directed. | 6 | Each | 5,500 ₹33,000 Lowest | 7,000 ₹42,000 | 7,500 ₹45,000 |
| 5.00 | Cutting including fixing of existing 100 mm bore GI pipe in position for taking down addition alteration or for repair complete all as specified and directed. | 10 | Each | 200 ₹2,000 | 120 ₹1,200 Lowest | 122 ₹1,220 |
| 6.00 | Cutting including fixing of existing 80 mm bore GI pipe in position for taking down addition alteration or for repair complete all as specified and directed. | 12 | Each | 190 ₹2,280 | 110 ₹1,320 Lowest | 115 ₹1,380 |
| 7.00 | Screwing ( Threads making ) of existing galvanised steel tubing of 100 mm bore for addition alteration extending or reducing in length for repair all as specified and directed. | 10 | Each | 400 ₹4,000 | 180 ₹1,800 Lowest | 190 ₹1,900 |
| 8.00 | Screwing ( Threads making ) of existing galvanised steel tubing of 80 mm bore for addition alteration extending or reducing in length for repair all as specified and directed. | 12 | Each | 350 ₹4,200 | 200 ₹2,400 Lowest | 210 ₹2,520 |
| 9.00 | S&F in repairs 50 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete all as specified and as directed. | 25 | Each | 1,500 ₹37,500 | 650 ₹16,250 Lowest | 655 ₹16,375 |
| 10.00 | S&F in repairs 40 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete all as specified and as directed. | 28 | Each | 1,400 ₹39,200 | 550 ₹15,400 Lowest | 555 ₹15,540 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
11 Aug 2025, 6:00 pmClosed
Durg Abhiyanta (Sena), Garrison Engineer (N) Tezpu
Durg Abhiyanta (Sena), Garrison Engineer (N) Tezpur, Military Engineer Service, PIN 901217 C/o 99 APO
REPAIR/MAINT OF PUMP HOUSE, OVER HEAD TANK UNDERGROUND SUMP AND FILTRATION PLANT OF PUMP HOUSE CENTRIFUGAL, SUBBERSIBLE, MONO BLOCK AND STARTER AT VARIOUS PLACE, REPLACEMENT OF WATER DISTRIBUTION PIPE LINE AND ALLIED WORK AT SECT I TO IV AT AGE CHARD
2025_MES_719720_1
GE(N)/TEZ/2025-2026/8174
Open Tender
Civil Works
Item Rate
180 days
AGE CHARDUAR UNDER GE (N) TEZPUR
AS PER NIT
8 documents required · 8 mandatory
₹500
Garrison Engineer (N) Tezpur
₹98,000
Yes
13 Sept 2025
10 Jul 2025
13 Aug 2025
10 Jul 2025
11 Aug 2025
23 Jul 2025
10 Jul 2025 - 23 Jul 2025
Amount
Supply and fix in replacement the starter submersible pump motor starter fully automatic star delta operated enclosed in sheet enclosure type for submersible pump motor AC-3 rating 50 HZ 3 phase of capacity 15 HP with single phase preventer complete including making necessary electrical connections all as specified and directed. Make- L&T /Schneider/Havells Note:these starter should be accomodate in existing panel and should fixed properly as previous one rating and space.
Supply and fix in replacement submersible pump motor starter fully automatic star delta operated enclosed in sheet enclosure type for submersible pump motor AC-3 rating 50 HZ 3 phase of capacity 20HP complete including making necessary electrical connections all as specified and directed. Make- L&T /Schneider/Havells. Note:these starter should be accomodate in existing panel and should fixed properly as previous one rating and space.
Supply and fix in replacement centrifugal /monoblock pump motor starter fully automatic star delta operated enclosed in sheet enclosure type for submersible pump motor of capacity 10-15 HP, AC-3 rating 50 HZ 3 phase complete all as specified and directed. Make: Havells/schneider/L&T Note:these starter should be accomodate in existing panel and should fixed properly as previous one rating and space.
M&L for construction for water level indicator of existing size made out of MS Sheet of 1.6mm thick complete including painting with super enamelled paint of white colour duly marked the water levels in red colour showing the levels of water inside the overhead tank including aero of existing size painted with red colour and fixed at the height of approx 50 feet testing complete all as directed.
Cutting including fixing of existing 100 mm bore GI pipe in position for taking down addition alteration or for repair complete all as specified and directed.
Cutting including fixing of existing 80 mm bore GI pipe in position for taking down addition alteration or for repair complete all as specified and directed.
Screwing ( Threads making ) of existing galvanised steel tubing of 100 mm bore for addition alteration extending or reducing in length for repair all as specified and directed.
Screwing ( Threads making ) of existing galvanised steel tubing of 80 mm bore for addition alteration extending or reducing in length for repair all as specified and directed.
S&F in repairs 50 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete all as specified and as directed.
S&F in repairs 40 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete all as specified and as directed.
S&F in repairs 25 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete all as specified and as directed.
S&F in repairs 20 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete all as specified and directed.
Supplying & laying in repairs trenches 100 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & laying in repairs trenches 80 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supply and fix in repairs MS flange heavy duty complete with nuts bolts and washers 06 nos suitable for 100 mm dia GI pipe complete all as specified and directed.
Supply and fix in repairs MS flange heavy duty complete with nuts bolts and washers 06 nos suitable for 80 mm dia GI pipe complete all as specified and directed.
M&L in replacement valve chamber cover with frame and locking arrangement made out of angle iron or other section and MS sheet with welding of holdfast etc. including hinges fabricated MS is not less than the thickness of frame all as specified including preparation of surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Material and labour for construction of brick masonry valve pit of size 60 cm x 60 cm x 60 cm (internal dimensions) with one brick thick wall in cement mortar (1:4) on 100 mm thick PCC (1:4:8) type D2 (using 40 mm graded aggregate) as in foundation, 15 mm thick rendering in cement mortar (1:4) internally and externally up to 15 cm below ground level including, provision of valve pit cover made out of 3 mm thick MS sheet welded with 40 x 5 mm thick flat iron all round, on ISA 40 x 40 x 6 mm frame, fixed with hold fast 150 mm long, embedded in PCC (1:2:4) type B1 (Block size 230 x 200 x 100 mm) with necessary hinges, handles, locking arrangement, including applying two coats of white wash on plastered surfaces and two coats of bituminious paint over a coat of red oxide primer on steel surfaces and ncessary earth work in soft/loose soil complete all as specified and directed.
Material and labour for construction of brick masonry valve pit of size 90 cm x 90 cm x 90 cm (internal dimensions) with one brick thick wall in cement mortar (1:4) on 100 mm thick PCC (1:4:8) type D2 (using 40 mm graded aggregate) as in foundation, 15 mm thick rendering in cement mortar (1:4) internally and externally up to 15 cm below ground level including, provision of valve pit cover made out of 3 mm thick MS sheet welded with 40 x 5 mm thick flat iron all round, on ISA 40 x 40 x 6 mm frame, fixed with hold fast 150 mm long, embedded in PCC (1:2:4) type B1 (Block size 230 x 200 x 100 mm) with necessary hinges, handles, locking arrangement, including applying two coats of white wash on plastered surfaces and two coats of bituminious paint over a coat of red oxide primer on steel surfaces and ncessary earth work in soft/loose soil complete all as specified and directed.
Supply and fix in replacement of submersible copper cable of size 10 sq mm 3 core all as specified and as directed.
Supply and fix in repair flange less butter fly valve quarter turn 150 mm bore lever operated for pressure filter including all fixing materials such as nuts, bolts and washers of required size all as specified.
Supply and fix in repair flange less butter fly valve quarter turn 100 mm bore lever operated for pressure filter including all fixing materials such as nuts, bolts and washers of required size all as specified.
Supply and fix in repair flange less butter fly valve quarter turn 80 mm bore lever operated for pressure filter including all fixing materials such as nuts, bolts and washers of required size all as specified.
Supply and fix 150 mm bore sluice valves cast iron body PN-1.0 complete with brass spindle and hand wheel including joints and fixing material including taking down old unsv sluice valve complete all as specified and directed.
Supply and fix 100 mm bore sluice valves cast iron body PN-1.0 complete with brass spindle and hand wheel including joints and fixing material including taking down old unsv sluice valve complete all as specified and directed.
Supply and fix 80 mm bore sluice valves cast iron body PN-1.0 complete with brass spindle and hand wheel including joints and fixing material including taking down old unsv sluice valve complete all as specified and directed.
M&L for repairing existing chemical dosing pump simple diaphragm type coupled with 0.5 HP 440 Volts AC 1440 RPM motors suitable for from 100 ltrs capacity dosing tank of any specification and making dosing pump , strainer and siphon valve and pressure filt valve etc functional complete all specified and directed by Engr-in-Charghe at site. . Note : Rates for PVC wire wooven (re-inforced) heavy duty flexible pipe from chemical dozing pump to venturi , along with ferrul and non return valve,repair to pump and motor etc is deemed to be inclcuded in the quoted rates. Note :- Old unsv pump moter deposite to store yard complete direction by Engr-in-charge
M&L for taking out of defective booster pump/centrifugal pump 10-15 HP and taking out burnt out windings,cleaning of motor rotor and stator with cleaning material. Rewinding of motor with super enamelled copper wire of existing gauge including replacement of unserviceable parts including transportation. Assembling of motor and testing complete to the satisfaction of Engineer-in -Charge. Note: all cost for repair/replacement part of accesories for the motor/pump deemed to included in quoted rate no separate cost will be provided.
M&L for taking out of defective submersible pump set of any discharge capacity from borewell including dismantling/taking out column pipe of any size/length alongwith submersible cable,nuts,bolts etc and lowering down the pump set alongwith coloumn pipe after carrying out necessary repairs/replacement of defective parts including replacement of old gaskets and testing on completion all as specified and directed.
Strip opening of submersible motor 15/20/22.5 HP and taking out burnt windings,cleaning of motor rotor and stator with cleaning material,carrying out necessary machining work such as grinding, metaling and polishing and rewinding of motor with stove enamelled copper wire of existing gauge,replacement of unserviceable parts as required. Assembling of motor and testing complete upto entire satisfaction of Engineer-in -Charge for 15/20/22.5 HP complete all as specified and directed.Note :- Spare required shall be measured and paid separately under respective item here in after
Supply only motor bush upper and lower in repair spare parts of submersible motor of capacity 15 to 20 HP of any make & model complete all as specified and directed
Supply only Rotor bearing sleeve upper and lower in repair spare parts of submersible motor of capacity 15 to 20 HP of any make & model complete all as specified and directed
Supply only Sand guard in repair spare parts of submersible motor of capacity 15 to 20 HP of any make & model complete all as specified and directed
Supply only Motor thrust plate assy in repair spare parts of submersible motor of capacity 15 to 20 HP of any make & model complete all as specified and directed
Supply only Motor coupler sleeve with key in repair spare parts of submersible motor of capacity 15 to 20 HP of any make & model complete all as specified and directed
M&L for development existing of bore well of depth upto 120 mtrs for 12-24 hours with air compressor machine at desired air pressure till clear sand free potable water is obtained from the bore well including taking out submersible pump motor, cable and column pipe of any description or size and re-lowering the pump set alongwith existing column pipes, submersible cable of any make/size and nuts bolts & washers of suitable size/length including making all electrical connectios after completion of developemnt work and testing for required yeild of ground water all as directed by Engr-in-Charge at site. Note:the aircompressor if required beyond the 12 hours for proper yield of water from borewell then it should be deemed in quoated rate by the contractor.
M&L for taking out and down after repair of submersible pump motor, cable and column pipe of any description or size and re-lowering the pump set alongwith existing column pipes, submersible cable of any make/size including replacement as per requirement for nuts bolts & washers of suitable size/length including making all electrical connectios after completion of developemnt work and testing for required yeild of ground water all as directed by Engr-in-Charge at site. Note: Moter and column pipe and cable measurement and paid seperately.
Supply, install testing and commissioning in repairs submersible pump, electric driven 415V, Three phase 20 HP suitable for 100mm dia column pipe including tail piece and flange (Casing pipe size 350mm) having discharge capacity 16 LPS at 65.00 metre head alongwith suitable capacity of 20 HP electric motor all as specified and directed. Make : kirloskar/ KSB/CG
S&F in repairs Booster pumps 15 HP for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 30mhead, any discharge all as specified and as directed by Engr in charge for supply of distribution line beween pump house to diffrent sector incld neccessary replacement of burn out of items. Note :- Old unsv pump moter deposite to store yard complete direction by Engr-in-charge
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
M&L for repairs/rectification of leakage in UG cast iron /Galvanised iron pipe by means of choking lead wool/ pig lead or tightening of GI fittings complete including excavation and earth work for exposing the joints and working space on the site, returning, filling in and making good to the existing earth level of the surroundings after repair for the 100/110 mm bore sizes of pipes all as specified. Note;- (i) Rectification of leakage shall be attended and rectified by the contractor on the same day of reporting by the Engr-in-charge. Non rectification of leakage of pipe line shall be viewed as serious lapse on contractor's part and penal charges as Rs 100/- per complaint (ii) Supply only Lead wool/pig lead shall be measured and paid seperately. (iii) In case excavation beyound 1 mtr from both side of the joint is required the same shall be measured and paid separately under respective item. Note:- (i) Rectification of leakage shall be attended and rectified by the contractor on the same day of reporting by the Engr-in-charge. Non rectification of leakage of pipe line shall be viewed as serious lapse on contractor's part and penal charges as Rs 100/- per complaint shall be imposed on contractor.(ii) Supply only Lead wool/pig lead shall be measured and paid seperately.(iii) In case excavation beyound 1 mtr from both side of the joint is required the same shall be measured and paid separately under respective item. (iv) GI/PPR pipes alongwith fittings shall be measured and paid separately.
M&L for repairs/rectification of leakage in UG cast iron /Galvanised iron pipe by means of choking lead wool/ pig lead or tightening of GI fittings complete including excavation and earth work for exposing the joints and working space on the site, returning, filling in and making good to the existing earth level of the surroundings after repair for the 80/90 mm bore sizes of pipes all as specified. Note;- (i) Rectification of leakage shall be attended and rectified by the contractor on the same day of reporting by the Engr-in-charge. Non rectification of leakage of pipe line shall be viewed as serious lapse on contractor's part and penal charges as Rs 100/- per complaint (ii) Supply only Lead wool/pig lead shall be measured and paid seperately. (iii) In case excavation beyound 1 mtr from both side of the joint is required the same shall be measured and paid separately under respective item. Note:- (i) Rectification of leakage shall be attended and rectified by the contractor on the same day of reporting by the Engr-in-charge. Non rectification of leakage of pipe line shall be viewed as serious lapse on contractor's part and penal charges as Rs 100/- per complaint shall be imposed on contractor.(ii) Supply only Lead wool/pig lead shall be measured and paid seperately.(iii) In case excavation beyound 1 mtr from both side of the joint is required the same shall be measured and paid separately under respective item. (iv) GI/PPR pipes alongwith fittings shall be measured and paid separately.
M&L for repairs/rectification of leakage in UG cast iron /Galvanised iron pipe by means of choking lead wool/ pig lead or tightening of GI fittings complete including excavation and earth work for exposing the joints and working space on the site, returning, filling in and making good to the existing earth level of the surroundings after repair for the 50/63/40/32 mm bore sizes of pipes all as specified. Note;- (i) Rectification of leakage shall be attended and rectified by the contractor on the same day of reporting by the Engr-in-charge. Non rectification of leakage of pipe line shall be viewed as serious lapse on contractor's part and penal charges as Rs 100/- per complaint (ii) Supply only Lead wool/pig lead shall be measured and paid seperately. (iii) In case excavation beyound 1 mtr from both side of the joint is required the same shall be measured and paid separately under respective item. Note:- (i) Rectification of leakage shall be attended and rectified by the contractor on the same day of reporting by the Engr-in-charge. Non rectification of leakage of pipe line shall be viewed as serious lapse on contractor's part and penal charges as Rs 100/- per complaint shall be imposed on contractor.(ii) Supply only Lead wool/pig lead shall be measured and paid seperately.(iii) In case excavation beyound 1 mtr from both side of the joint is required the same shall be measured and paid separately under respective item. (iv) GI/PPR pipes alongwith fittings shall be measured and paid separately.
M&L for repairs/rectification of leakage in UG cast iron /Galvanised iron pipe by means of choking lead wool/ pig lead or tightening of GI fittings complete including excavation and earth work for exposing the joints and working space on the site, returning, filling in and making good to the existing earth level of the surroundings after repair for the 25/20 mm bore sizes of pipes all as specified. Note;- (i) Rectification of leakage shall be attended and rectified by the contractor on the same day of reporting by the Engr-in-charge. Non rectification of leakage of pipe line shall be viewed as serious lapse on contractor's part and penal charges as Rs 100/- per complaint (ii) Supply only Lead wool/pig lead shall be measured and paid seperately. (iii) In case excavation beyound 1 mtr from both side of the joint is required the same shall be measured and paid separately under respective item. Note:- (i) Rectification of leakage shall be attended and rectified by the contractor on the same day of reporting by the Engr-in-charge. Non rectification of leakage of pipe line shall be viewed as serious lapse on contractor's part and penal charges as Rs 100/- per complaint shall be imposed on contractor.(ii) Supply only Lead wool/pig lead shall be measured and paid seperately.(iii) In case excavation beyound 1 mtr from both side of the joint is required the same shall be measured and paid separately under respective item. (iv) GI/PPR pipes alongwith fittings shall be measured and paid separately.
Supply only pig lead for rectification of leakage of joints of CI pipe all as specified.
Supplying & laying in repair trenches 100 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & laying in repair trenches 80 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & laying in repair trenches 50 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & laying in repair trenches 40 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & laying in repairs trenches 32 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supply and fix in replacement of 25 mm dia of water tubing to tube medium grade galvanised with all fittings laid in trenches complete all as specified and directed.
Supply and fix in replacement of 20 mm dia of water tubing to tube medium grade galvanised with all fittings laid in trenches complete all as specified and directed.
M&L in repairs run lead joint for spigot and socket cast iron pipes and fittings of nominal bore 100 mm complete all as specified and as directed.
M&L in repairs run lead joint for spigot and socket cast iron pipes and fittings of nominal bore 80 mm complete all as specified and as directed.
S&F for cutting of CI/DI pipe150/ 100 mm dia carefullyfor new connection of distribution in position inserting fittings such as bend, tee, socket pieces, collar etc; complete all as specified and as directed.Note: necessary fitting for insertion of hole in DI pipe is incld in the above item no extra cost will be paid complete all as specified and as directed
Labour for collecting complaints in writting pertaining to external water supply system from concern JE at AGE Charduar office for various areas under AGE Charduar in writting during the hours as fixed by the Engr-in-Charge and detecting faults in distribution system/delivary or rising main system of any size or bore and any type/size of pipes laid in trenches/with wall/on floor/ to overhead tanks of any capacity/size at any height in any area under AGE Charduar and rectify the fault to restore the water supply services in all respect and upto entire satisfaction of Engr-in-Charge and comprising of the followings:-(a) Person collecting the complaints/deputed by the contractor shall have sound knowledge of repairing/maintenance of CI/DI/PPR pipes and he will visit the site to assess the actual requirement/nature of fault in water supply system and also shall repair minor repairs to PP-R pipelines/CI/DI/GI pipe lines of any dia sponteneously. (b) If any complaint left unattended by the the contractor ,penalty @ Rs 1000/- per complaint per day be imposed on contractor. (c ) Contractor shall be resposible to communicate the concern JE/AGE E/M regarding any major breakdown/fault within 30 minutes if the problem is of specific nature. (d) Contractor shall be resposible for providing suitable transport to person deputed by him and shall be bound to reach at site within 30 minutes after receiving the complaint. (e ) Necessary T&P required to repairs all defects/faults shall be provided by the contractor and cost shall be deemed included in unit rate quoted by the contractor. (f) Requirement of specific spares/stores such as CI/DI/PPR pipes and their respective fittings, sluice/gate and spares of water supply plants/equipments,excavation/earth work if required will be given by the contractor well in advance to Engr-in-charge/JE E/M.
Supply and laying complete all as specified and as directed. submersible cable 10 sqmm 3 core flat cable copper conductor, ISI marked complete all as specfied and directed. Make : Finolex/ Havells/ Polycab 50 rm
Supply and lay in repairs Pipes ERW Steel including specials, nominal dia 80 mm as per IS 3589 (1981) thickness 6.0 mm both end flanged 3.0 mtr long fitted with flanges at both ends made out of heavy grade pipes of not less than 6mm wall thickness ISI marked IS:3589-1981 complete with bolts,nuts,gasket etc as required at site complete all as specified and directed.
Supply, install testing and commissioning in repairs submersible pumpset complete , electric driven 415V, Three phase 25 HP suitable for 100mm dia column pipe including tail piece and flange (Casing pipe size 350mm) having discharge capacity 16 LPS at 65.00 metre head alongwith suitable capacity of 25 HP electric motor all as specified and directed. Make : kirloskar/ KSB/CG Note :- Old unsv pump moter deposite to store yard complete direction by Engr-in-charge
Supply and fix in repairs Valve, reflux, with by-pass Arrangement (NRV), 150 mm (6”) dia etc complete all as specified and directed.
Material and labour for construction of brick masonry valve pit of size 90cm x 90cm x 90 cm (internal dimensions) with one brick thick wall in cement mortar (1:4) on 100 mm thick PCC (1:4:8) type D2 (using 40 mm graded aggregate) as in foundation, 15 mm thick rendering in cement mortar (1:4) internally and externally up to 15 cm below ground level including, provision of valve pit cover made out of 3 mm thick MS sheet welded with 40 x 5 mm thick flat iron all round, on ISA 40 x 40 x 6 mm frame, fixed with hold fast 150 mm long, embedded in PCC (1:2:4) type B1 (Block size 230 x 200 x 100 mm) with necessary hinges, handles, locking arrangement, including applying two coats of white wash on plastered surfaces and two coats of bituminious paint over a coat of red oxide primer on steel surfaces and ncessary earth work in soft/loose soil complete all as specified and directed.
M&L for dismantling/taking down old corroded angle bracing of any size or type/pressed steel plate/nuts, bolts & washers etc inside the pressed steel overhead tank capacity 9600 Gallon mounted on 15 mtr staging tank of any description by dismantling the welding joints from gusset plate complete all as required at site to repair these all as specified and directed.
M&L for replacement of angle iron bracing of size and thickness as per existing (65x65x6mm) inside the steel overhead tank/clear water tank/ladder,platform and similar work including making necessary arrangement for holding of surrounding plates and bracing, cutting of gusset plates to required sizes and shape & angle for joiting with bracings by drilling holes welding of web piece with gusset plate wherever required after making proper shape etc complete at the height not less than 15 mtr all as specified and as directed.
M&L for dismantling/taking down old corrogated/MS plain sheet top cover of any thickness from the pressed steel OH tanks by unscrewing nuts & bolts and washers of suitable size complete all as specified.
M&L for fixing in repairs MS plain sheet of size 3.0 mm thick cut to proper shape for top cover including necessary fabrication & welding and including nut and bolts and washers of suitable size including welding with hinges of suitable sizes & including painting with two coats of black bituminious paint of suitable quality for water supply purpose over a coated of red oxide primer complete at PS OH tank and clear water tank all as specified and directed.
Dismantling and taking down old corroed PS plate of any size from the pressed steel over head tank by unscrewing nut & bolts or cutting joints and removing of nut & bolts etc including joiting material complete at the height of 15 mtrs complete all as specified and directed.
S&F in repairs factory made factory made pressed steel plate of size 1.22m x 1.22 x 6mm thick fixed with suitable size nuts and washers including all jointing material such as lead wool, gasket, non toxic black puitty washer etc and applying two coats of anti corrosive paint suitable for potable water complete at the height of 50 feet approx all as specified and directed.
M&L for painting of complete tank (external surface) of capacity 9600 Gallon including staging, ladder, rasing & delivery mains with two coats of synthetic enamel paint (one unded coat, one finishing coat) after preparartion surface ,one coat of primer red oxide zinc chromium & unwanted foreign material with wire brush, complete at the height 15 mtr all as specified and directed.
M&L for applying two coats of anticorrosive bituminuos paint lead free suitable for potable water to internal surfaces of PS tank of capacity 9600 gallon after preparartion of old painted surface rust and any other unwanted foreign material with wire brush, complete at the height 15 mtr all as specified and directed.
M&L in repairs construction for MS float box made out of MS Sheet 1.6mm thick and of size 30 x 30x 25cm complete painting black bituminuos paint incl supply and fixing of nylon rope of including construction of water level indicator of existing size made out of MS sheet of 1.6mm thick complete including painting with super anamelled paint of white colour duly marked with water levels in red colour showing the levels of water inside the overhead tank including arrow of existing size painted with red colour and fixed at the height of 50 feet and testing complete all as specified and as directed.
M/S RUSTAM ALI (BID ID -3383543)
Raj Enterprise (BID ID -3383466)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .