| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC PLOT NO D 2 COAL DEPOT FOSBERY ROAD SEWRI E MUMBAI 400 015 | MUMBAI | MUMBAI | MAHARASHTRA | 400015 | L1 | Accepted-AOC BEING THE LOWEST BIDDER | |
| 2 | L2₹28.6 L+₹2.7 L (10.5%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹32.9 L+₹7.0 L (27.2%)Rejected-Finance 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
24 Oct 2024, 6:00 pmClosed
GE (AF) BARODA
GE (AF) BARODA ,DARJIPURA , GUJARAT-390022
REPAIR/ REPLACEMENT OF INTERNAL ELECT, DB, SUBMAIN WIRING, FLAME PROOF LIGHT/ FLAME PROOF SWITCH, EARTHING AND PETTY/ DAY TO DAY MAINT AT OTM AND TECHNICAL ACCOMODATION AT MAKARPURA AT AFS VADODRA
2024_MES_671736_2
8913/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
MAKARPURA
AS PER NOTICE OF TENDER
8 documents required · 8 mandatory
₹500
Yes
GE (AF) BARODA
₹48,000
Yes
26 Nov 2024
4 Oct 2024
26 Oct 2024
4 Oct 2024
24 Oct 2024
11 Oct 2024
Amount
Taking down carefully copper / Aluminium point wiring including (light, fan, socket or power complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs etc all as directed.
Material and labour for point wiring for one light point or one fan point or one fan point controlled by one switch with using 1.5 Sq mm (nominal area) stranded copper conductor single core, PVC insulated & unsheathed cable, 1100 volts grade in existing concealed PVC conduit (medium grade) of 20mm dia/as exist on site all as specified and directed with using new sunken type Pre - coated 120 GSM (Gram Per m²) GI sheet pressed steel box including modular cover plate for mounting modular switch socket etch incl all accessories and using 1.5 Sq mm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable (In green colour) as in earth wire connected to common earth dolly complete all as specified and directed.
One light point controlled by one one/way switch.
One Fan point controlled by one one/way switch.
One 3 pin 5 Amps socket outlet on same board with other switch.
One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size.
One bell point controlled by one way switches
One light point controlled by two way switches
All as per item No. 2 above but using 2.5 Sqmm PVC insulated, unsheathed cable for one 3 pin socket outlet 15 Amps on independent board.
All as per item No.2 above but wiring with 4 sqmm multistranded copper conductor unsheathed and 4 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board.
M&L for point wiring for one light or one fan point controlled by one switch with using 1.5 Sq mm (nominal area) stranded copper conductor single core PVC insulated & unsheathed cable 1100 volts grade in and incl PVC casing and capping of suitable size fixed on surface all as directed with using new sunken type pressed steel box/terminal boxes for mounting fittings/junction boxes not less than 1.6 mm thick duly painted with two coats of black bituminous paint over a coat of red oxide primer with and incl all accessories and using 1.5 Sq mm (nominal area) stranded copper conductor single core conductor PVC insulated & unsheathed cable as in earth wire connected to commen earth dolly complete all as specified and directed.Make PVC cable .Havells/Finolex/Polycab Note : (i) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface with using PVC of covering sunken boards /terminal boxes/junction boxes of any shape and size with 3 mm thick suitable GI screws and cup washers. (ii) Fititngs like switches, sockets, regulators lamp holders light fittings shall be measured and paid appropriate item of schedule ‘A’ (iii) The size of conduits shall be determined on permissible No of runs of wires as specified in SSR part- I however minimum size of conduit shall be 20 mm dia (medium grade).
One light point controlled by one one/way switch.
One Fan point controlled by one one/way switch.
One 3 pin 5 Amps socket outlet on same board with other switch.
One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size.
One light point controlled by two way switches
All as per item No.5 above but wiring with 2.5 sqmm multistranded copper conductor unsheathed and 1.5 sqmm copper conductor unsheathed cable as earth continuity conductor for one 03 pin 15 Amps socket outlet point on independent board.
Dismantling and M & L for sub main wiring using two single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Casing Caping/PVC Conduit or in existing concealed conduit(as required & directed by Engr-in-Charge)accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 4 Sqmm earth wire, PVC insulated & unsheathed all as directed.Make PVC cable .Havells/Finolex/Polycab Note: (i) Two runs of 6 sqmm and one run of 6 sqmm cable and one run of PVC conduit shall be measured as one RM. (ii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall be included in the unit rate quoted .
All as above item No- 7 but using 4 Sqmm cable for phase and neutral and 4 Sqmm for earth.Make PVC cable .Havells/Finolex/Polycab Note: (i) Two runs of 4 sqmm and one run of 4 sqmm cable and one run of PVC conduit shall be measured as one RM. (ii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall be included in the unit rate quoted .
All as above item No.7 but using two run single core 2.5 Sqmm cable for phase and neutral and 2.5 Sqmm single core PVC ZHFR insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed.Make PVC cable .Havells/Finolex/Polycab Note: (i) Two runs of 2.5 sqmm and one run of 2.5 sqmm cable and one run of PVC conduit shall be measured as one RM. (ii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall be included in the unit rate quoted .
Attending the complaints lodged by the occupants/users of electrification nature & rectification of the fault as per the complaint lodged by the user in any time in respect of main fixture /breakdown for light/fan/bell/light or power socket and LT line etc complete repairs to the extent by removing connections from the system removing faults in wires, battens, conduit, sunken boxes, junction boxes, main switches, MCBs/DBs utility light fitting, lamp holders AC ceiling/ Exhaust fans and other type of complaints to connected fixtures of the internal electrification including providing of petty stores such as wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tape, screws , nuts as required to rectified the fault with regard to the complaint lodged and refixing of fittings, fixtures to their position as dismantled and respect of item if required to be paid under respective item as required complete all as directed at site to the entire satisfaction of Engr-in-Charge/users. Note :- (a) Repair/ replacement of switches, fan, regulator , replacing burnt/ damaged wiring , replacement of burnt MCBs and main switch , voltage fluctuation, current leakage, repair of street lights, and replacement of tube lights and no light etc will be attended with in 8 Hrs as urgent nature. (b) The complaints will be attended by electricians & respective helpers during day and night hours without delay.
Attending the complaints lodged by the occupants/users including Identifying and rectifying of electrification nature & rectification of the fault as per the complaint lodged by the user in day time 8.30 Hrs to 1730 Hrs No light complaint, loose wire, sparking etc. in DB/ LT panel at AFS Makarpura any emergency complain and any type of Complain regarding electricity all as directed by Engr-in-Charge.
NOTE FOR ITEM NO 1 to 10 :- (a) All T & P/Stationeries and labour team required comprising of sufficient trained technician (Electrician/helper ) will be provided by the contractor daily for location ie AFS Makarpura baroda area as directed.During MES mela or any other occason the contractor will be arrage additional menpower to rectify the complaint with justified time. b) Rep of the contractor will present in complaint cell & responsible for receiving & attending the complaints from 08.30 Hrs to 17.30 Hrs the time of lodging the complaint. In absence of rep of Contractor penal recovery as decided by GE shall be imposed & on contractor. (c) Cost of minor stores such as screws,clamps,insulation tapes,nuts/bolts, nail of required size, lubricating oil/grease etc shall be deemed included in the above quoted rate. However, major items such as switches, sockets, bell push, fan regulator, capacitor, wires etc shall be measured and paid separately under appropriate items of Schedule 'A'. (d) Complaints where complete replacement of circuit/point wiring required shall be measured under relevent item. (e) If contractor fails to rectify the complaint with in 24 hours after receiving, Rs 500/- per complaint will be penalised.
(c) The complaint will be taken from complaint cell. (d) All necessary tools & plants i.e. multimeter, tong tester, spanner set, wrench, screw driver set, combination plier, testing lamp set, drilling machine, bamboo ladder, blower/ vaccum cleaner, crimping tool, cutting and chasing tool, insulation megger , etc will have to kept by each tradesman engaged by contractor at his own cost. (e) Any accident/ mishappening occurred during the execution of work shall be responsibility of Contractor. (f) One MOBILE PHONE should also be provided by contractor to the each trademan engaged by him with incoming & out going facilities for normal and after working hours also so as to contact him in case of emergency during the entire period covered under the contract to keep liaison / communication with MES staff . (g) Complaint register and complaint slip shall be providing by the contractor duly printed with CA No and firm and the cost is deemed to be included in unit rate.(h ) Cost of material for replacement of new items shall be measured and paid separately under relevant items of Sch A/BOQ (i) Labour only for attending complaint like fixing of switches, sockets, regulators, ceiling rose,bell push, lamp holder, sunken box, PVC platelaying of wire all in any type etc.(ii) Labour only for attending complaint like fixing of LED batten any size,T-08 fittings,LED 2x2 recess mounting lights, fan blade, ex fan louvers,pvc EX fan, PVC conduit fixing any size (iii) Labour only for attending complaint like no light,loose connection,burnt wire repair any type etc (iv) Labour only for attending complaint like fixing of AC socket/top/DBS/MCBs/MCCBs./loose connection (v) Labour only for attending complaint such as phase balancing by sharing load
Supply only switch piano Modular type single pole one way 6 Amp 240 Volts. Make: Havells/Anchor/Plaza
Supply only switch piano Modular type single pole one way 16 Amp 240 Volts.
Supply only switch piano Modular type single pole two way 6 Amp 240 Volts.
Supply only socket only 6 Amps 2 in 1 Socket with Shutter Modular type 240 Volt.
Supply only socket only 6/16 Amps Twin Socket Modular type 240 V .
Supply only Bell push switch Modular type single pole one way 10 Amp 240 Volts.
Supply only Fan Regulator 1/2M FSC Modular type 240 Volts. Make: Havells/Anchor/Plaza
Supply only piano switch flush type 5 Amps single pole, one way, 230 volts AC circuit complete all as specified & directed. Make Anchor or/Cona/Havells/HPL.
Supply only piano switch Swich piano, bell push, 6 Amps, flush type, 230/250 Volts, 50 Hz supply. Make Anchor or/Cona/Havells/HPL.
Supply only piano switch flush type 15 Amps single pole, one way 230 volts AC circuit complete all as specified and directed by Engineer-in-Charge. Make Anchor or/Cona/Havells/HPL.
Supply only socket out let 2 in 1, 3 pin 5 Amps flush type, 230 volts Ac circuit complete all as specified and directed. Make Anchor or/Cona/Havells/HPL.
Supply only socket out let 2 in 1 multipurpose three pin, 15 Amps & three pin 5 Amps controlled by one switch, flush type 230 volts AC circuit complete all as specified & directed. Make Anchor or/Cona/Havells/HPL.
Supply only Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal.
Supply only Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal.
Supply only Switch socket combination with board 2 in 1, 3 pin, 5 and 15 Amp flush type universal.
Supply only Switch socket combination with board 2 in 1, 3 pin, 5 Amp flush type universal.
Supply only stepped type fan regulator flush type 01/02 Module both on the existing phenolic laminated sheet etc. as reqd.
Supply only for ceiling rose PVC polycarbonate isolated body 63.5x20 mm three terminal complete all as specified and directed. Make Anchor or/Cona/Havells/HPL.
Supply only for lamp holder PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. Make Anchor or/Cona/Havells/HPL.
Supply only door bell ding dong, multi tune, Chime and Buzzer. Make. Ancher, syska, havells
Supply only Concealed Galvanised (GI) metal flush Boxes Modular 3 module with white cement concealed and making good the disturbed surface by white cement & Existing color of bld distamper complete and all as directed by Engr-in-charge. Note:- Cost of labour paid separatly.
Supply only Concealed Galvanised (GI) metal flush Boxes Modular 4 module with white cement concealed and making good the disturbed surfaceby white cement&Existing color of bld distamper complete and all as directed by Engr-in-charge. Note:- Cost of labour paid separatly.
Supply only Concealed Galvanised (GI) metal flush Boxes Modular 6 module with white cement concealed and making good the disturbed surfaceby white cement & Existing color of bld distamper complete and all as directed by Engr-in-charge. Note:- Cost of labour paid separatly.
Supply only white cover plates with frame (white) Modular type 2 way complete Make: Havells/Anchor/Plaza
Supply only white cover plates with frame (white) Modular type 3 way complete Make: Havells/Anchor/Plaza
Supply only white cover plates with frame (white) Modular type 4 way complete Make: Havells/Anchor/Plaza
Supply only white cover plates with frame (white) Modular type 6 way complete Make: Havells/Anchor/Plaza
Supply only white cover plates with frame (white) Modular type 8 way complete Make: Havells/Anchor/Plaza
Supply only sheet metal enclosure SP with two pin and socket with one single pole MCB 25 Amps ,'B Curve 240 Volts complete all as specified .C&S/Havells/ Legrand
Supply only metal clad plug top and socket of any description of 25 Amp 3 pole 230 volts complete all as specified and directed.
Supply only Plug top 15 amps all as specified and directed
Supply only Plug top 5 amps all as specified and directed
Supply & fix, repair in testing of Electronic driver unit 2x2 sqaure or round shape fittings any type all as specified and directed.
Supply & fix, repair in testing of Electronic driver unit 30 watt Security light fittings any type all as specified and directed.
Supply only LED security light luminaire 30 watt freedom , pressure die cast aluminum housing, heat resistant glass, IP66 protection, better optics for uniform distribtion complete with all accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light complete.
Supply only LED batten 10 Watt (Mirror Light) 2 Feet with polycarbonate housing and diffuser AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable from ceiling rose to connector of the light, fixing the same complete all as per specified and directed.
Supply only LED batten 20 Watt with polycarbonate housing and diffuser AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable from ceiling rose to connector of the light, fixing the same complete all as per specified and directed.
Supply only LED light fitting recess mounted/pendent mounting ultraslim LED flat panel 2x2 down light aluminium extruded housing with full opal diffuser IP 20 suitable for perfect lighting condition 36 watt 240 volt, 50 Hz AC supply.
Supply only LED BULK Head Light of 12 Watt with polycarbonate housing and diffuser AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable from ceiling rose to connector of the light, fixing the same complete all as per specified and directed.
Supply only MCB FP pole 63 amps 415 Volts C series. Make. Schneider /Seimens /Legrand .
Supply only MCB, single pole 240 volts 6 to 32 Amps capacity C series fixed in DB's. Make : Schneider / Seimens /Legrand.
Supply only MCB, single pole and neutral link 240 volts 6 to 32 Amps capacity C series fixed in DB's. Make : Schneider / Seimens /Legrand.
Supply only MCB, single pole 240 volts 40 to 63 Amps capacity C series fixed in DB's. Make : Schneider / Seimens /Legrand.
Supply only MCB, single pole and neutral link 240 volts 40 to 63 Amps capacity C series fixed in DB's. Make : Schneider / Seimens /Legrand.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 toends or edges of landings, steps,cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good,cutting exceeding 20cm girth
Supply only of PVC conduit size 20 mm Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories including chase cutting such as couplers, lock nuts, saddles, pipe hooks etc
Supply only LED bulb 09 Watt 5 star rating.
Supply only FR-LSH PVC insulated,unsheathed,single core,flexible copper conductor wir suitable upto voltage grade 110 volt of different colours and following sizes.
Supply only ceiling fan 1200 mm 5 star rating metallic white, dust resistant with remote control. Make- Havells CAT PART NO.-Efficiencia (BLDC) 32 Watt.
Supply only wall mounted fan 400 mm Hi-Speed min 1350 RPM metallic white, dust resistantwith remote control.
Supply only Exhaust Fan fan 300 mm Hi-Speed 1350 RPM metallic white, dust resistant
Supply only Exhaust Fan fan 380 mm Hi-Speed 1350 RPM metallic white, dust resistant.
Supply and fix in repairs MCB DB 4 way VTPN Load line vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting with one MCCB 125 Amp TPN 30 KA as incommer and MCB SP/TP as OG complete all as specified. (Make. Schneider /Seimens /Legrand . (Note : Rate of MCCB is deemed to be included with unit rate of item. MCB SP/TP shall be measured and paid seperately under appropriate items of this schedule . Note : Copper thimble shall be used for connection of cable .
Supply and fix in repairs MCB DB 4 way TPN DB sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting with one MCB as incommer complete all as specified. (Make. Schneider /Seimens /Legrand . (Note : MCB SP/TP shall be measured and paid seperately under appropriate items of this schedule . Note : Copper thimble shall be used for connection of cable .
S & F in repairs MCB DB 4 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified. (Make: Schneider- Seimens /Legrand/Havells/C &S /L&T) . Note : Copper thimble shall be used for connection of cable .
All as per item No 65 above but 8 way . Make : Schneider /Seimens /Legrand/Havells/C&S /L&T
All as per item No 65 above but 12 way. Make : Schneider /Seimens /Legrand /Havells/C%S/L&T
Material and labour for taking down of ceiling/exhaust/wall mounted fan of any size and location for stripping of fan,washing throughly of bearing/bush by petrol, washing/cleaning fan blade, body greasing and oiling complete and refixing the same position after complete repairs including provision of twisted twin core flexible wire of size 23/0.0076 nt less than 0.5 sqmmand testing of fan on full load to entire satisfaction of Engr-in-charge complete all as specified and directed. Note for above itemNo.-68 a) Replacement of u/s spare parts as required shall be measured and paid seperatly under respective items. B) Rewinding shall be measured and paid seperatly.
M & L for rewinding of ceiling fans 1200/1400mm sweep any make with capacitor, suitable size of super enamelled copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc., reassembling including Taking out from site and transportation to local workshop refxing and testing complete.
M & L for rewinding of Exhaust fan 300 mm sweep any make with suitable size of super enamelled copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc., reassembling including Taking out from site and transportation to local workshop refxing and testing complete.
M & L for rewinding of Exhaust fan 380400/450 mm sweep any make with suitable size of super enamelled copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc., reassembling including Taking out from site and transportation to local workshop refxing and testing complete.
M & L for rewinding wall mounted fan of any sweep any make with suitable size of super enamelled copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc., reassembling including Taking out from site and transportation to local workshop refixing and testing complete.
M& L for bearing of ceiling fan 1200/ 1400 mm sweep.
M& L for bearing of exhaust fan 300/450 mm sweep
Supply and fix capacitor of capacity 2.5 Mfd (PVC body) including taking down.(Make:- EPCOS/JYOTI/ USHA)
Supply and fix capacitor of capacity 3.15 Mfd (PVC body) including taking down.
Supply and fix complete hanging assembly set comprising with rubber reel, MS clamps, nuts, bolts with one lock hole and lock pins suitable for any type of fans & down rods including taking down.
Supply and fix PVC insulated, flexible cable, twin core twisted of size 23/0.0076 with copper conductor in pieces for connecting fans including taking down. (Make: Havell’s / Finolex / Gloster )
Supply and fix down rod 15 mm dia and length upto 1 mtr as required on site, MS tube light grade, duly finished with powder coating of white colour, including necessary holes and threading etc. complete all as specified including taking down.
Taking down existing worn out louvers of any description , in any position and supplying & fixing new louvers made out of MS sheet 22 gauge thick suitable for exhaust fan of 450/300mm sweep all as specified & directed by Engineer-in-Charge.( Note: The louvers shall be of shape, size and pattern as approved by the Engineer-in-Charge duly painted with two of synthetic enamel paint over a coat of red oxide primer)
Matrial and labour for painting of Ceiling fan/Exhaust Fan including blade and hanging assembly with two coat of synthatic enamel paint from spray jet painting all as specified and directed by engr-in-Charge.
Supply and fix ceiling fan blade of size 1200 mm Sweep of material stanless steel flexible type suitable for all make fan all as specified and directed by engr-in-Charge.
Supply and fix Wall fan blade of size 300/350 mm Sweep of material stanless steel flexible type suitable for all make fan all as specified and directed by engr-in-Charge.
Supply and fix Ceiling fan canopy suitable of 1200/1400 mm sweep all as specified and directed by engr-in-Charge.
Supply and fixing flame proof LED lights fitting 01x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fix Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
Supply and fix Switch flame proof rotary type with termination box in LM6, 25A, double pole 250V complete all as specified and directed.
Supply and fix Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25A, 250V, 2P+earth complete all as specified and directed.
Material and labour for rewinding of Flame proof single phase Exhaust Fan of size 350 to 450 mm sweep including copper winding, bearing and other fixing accessories of suitable size complete all as directed by Engr-in-Charge.
Supply only Hylem sheet Size 9” x 11”x3 mm thick with Brass screw and washers with necessary slots reqired for mounting the fixtures complete of the following sizes fixed in repairs :-Make: Anchor as per sample
All as per above but size but size Size 10” x 12”
Supply only wall mounted light fitting suitable for retrofit LED lamp upto 14 watt B22 champagne gold finish fixture with plastic body, Opal white PC diffuser for glare free light complete all as directed by Engr-in-charge. Make : Havells/ Crompton/ wipro
BRITE INDUSTRIES (BID ID -3142521)
Badri Electricals (BID ID -3148436)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .