Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹32.3 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹34.3 L+₹2.0 L (6.22%)Rejected-AOC | 2 | Rejected-AOC L2 | |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
Tender Value
₹32.9 L
EMD Value
₹50,000
Closing Date
19 Apr 2023, 5:00 pmClosed
MANAGING DIRECTOR KSCADC
KSCADC 1st Floor, ChalachithraKalabhavan Building, Vazhuthacaud, Jagathy P.O. Thiruvananthapuram Pin-695014
KUFOS - PMMSY - Construction of Aquatic referral lab for KUFOS- Additional Work- Installation of DG set and UPS and associated civil works(RE-TENDER)
2023_SCADC_567014_3
ET-51/2022-23
Open Tender
Electrical Works
Item Rate
60 days
Panangadu
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,950
₹50,000
1 Jul 2023
12 Apr 2023
22 Apr 2023
12 Apr 2023
19 Apr 2023
12 Apr 2023
Amount
Electrification Work
od305124/2022_2023 : Supply, erection in the existing foundation, installation, testing and commissioning of 100 KVA, 3 Phase 415 Volts Silent DG Set comprising of Cummins make engine model 6BTAA5.9G13 developing 159 BHP at 1500 RPM Coupled to 100 KVA, 415 Volts, Stamford make alternator or equivalent Kirlosker or any other brand appd by the KSCADC mounted on a common base frame, complete with: fuel tank, Battery & Leads, Silencer-Residential, AVM Pads, First Fill of Lube, Acoustic Enclosure and STD Control Panel. (the rate including the loading unloading and conveyance)
90.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.2 : Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.4 : Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.5 : Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.14.6 : Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7 : Supply and providing copper earth bus in the panel board
5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
od305311/2022_2023 : S/F DCP fire extinguisher (5Kg): supply and installation of 5kg Dry chemical power type (DCP) fire extinguishers having ISI mark along with mounting supports etc.as required.
od305312/2022_2023 : Supply and installation of fire bucket with stand.
od305314/2022_2023 : Supply and providing Cable Route Marker
od305315/2022_2023 : Providing and Fixing of Electrical ISI<br>Grade Rubber Mat suitable for 440Volts<br>Switchboards.
od305318/2022_2023 : Electrical Inspectorate Approval related paper works Charges including connection charges, agreement charges, drawing preparation, Submission, etc as required. Preparation of all drawings and documents, Submission of Completion certificates to KSEB/Inspectorate for obtaining power connection etc. (The rate inclusive of all the statutory charges for the electrical inspectorate)
od305319/2022_2023 : Supply and fixing multi function meter on existing meter board and giving all connection for measuring 440V RYB phase voltage, RYB ampere, etc.
90.14.2.1 : Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.12.5.32 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 120 sq mm
90.12.6.32 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 120 sq mm
90.12.7.32 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm
90.12.10.2 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.12.10.4 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation77/63 mm or nearest size
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
od306254/2022_2023 : Painting letters or figures of the following size with enamel paint as identification mark to SB, DB, panel board etc as required. size as per the site condition and direction from the site engineer.
od306256/2022_2023 : supply, Installation, testing and commissioning of 200/5A, 5VA accuracy class 1, resin cast metering CT
od306266/2022_2023 : Supply installation testing and commissioning of RYB LED indication lights in the existing panel board
od306268/2022_2023 : Supply, Installation, Testing and Commissioning of 1000 VA/600 W UPS with in build 12 VDC, 7 Ah 2 number der type battery, with standard voltage, current and frequency. make: v guard sesto 1000 or any reputed brands
od306269/2022_2023 : Supply and installation of 14 sqmm to 120 sqmm. Copper earthing clips for single compression glands and giving all connections.
od310194/2022_2023 : Supply, installation, and commissioning of 3kva UPS stand-alone Configuration. Single phase in and out. with inbuilt isolation transformer (IP20) @ 3 kva Load Minimum VAH 3024 per UPS SMF battery of reputed approved make exide/quanta), Input pf 0.99, it shall be 100% generator compatible, with Efficiency > 83 % and output power factor unity (3kVA = 3kW), including all accessories etc as required. The acoustic noise at 1m of the system should be<55dB.The system shall comply to IEC /EN 62040-1,2,3 and relevant IS standard along. The system shall be true online double - conversion DSP based UPS system and also UPS shall be with automatic & manual bypass switch. The system shall have IGBT rectifier and inverter. warranty 2 years ups and batteries. including rack and inter connecting cables. (12v 42ahx 6 nos )
od310195/2022_2023 : Supply, installation, and commissioning of 30kw power cabinet 30kw UPS with min 6 modules Three phase in and out with vertical & horizontal paneling compatibility with indoor (IP21) with surge protection system with 30 min backup battery @ 30kw .8 PF load (SMF battery of reputed approved make exide/quanta/panasonic), having battery bank with Min VAH 31200 with dual battery bank per ups, Input pf >0.99, input THDi <3 % without use of any external filters, double conversion technology with input voltage range 320-460 @ full load, 50Hz Three Phase, output 400V, 50Hz Three phase, SNMP card for network monitoring compatibility etc. It shall be 100% generator compatible, with Efficiency > 96% and output power factor unity ( 30kVA= 30kW), Eco mode Efficiency 98% and including all accessories etc as required. The system shall comply to IEC /EN 62040-1 and relevant IS standard. The acoustic noise at 1m of the system should be <46dB.The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE, PEP (ISO14025) and relevant IS standards. The system shall be true online double - conversion DSP based UPS system and also UPS shall be with automatic bypass built-in. The system shall have IGBT rectifier and inverter. warranty 2 years for UPS and batteries.(12v 65ahx 40 nos Dual String SMF batteries with stand and interconnecting cables. )
2.1.2 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
2.2.1 : Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required100 Amp, 16 KA, TPMCCB
2.2.3 : Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required160 Amp, 16KA,TPMCCB
od315359/2022_2023 : Supply, Laying and clamping of 1 number PVC insulated and PVC sheathed armored <br>copper power cable of 1.1 KV grade of the fallowing size in the existing trench or DWC 12 core 2.5 sq mm copper under ground armored cable.
9.2.30 : Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm
90.12.5.42 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 25 sq mm
90.12.6.42 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 25 sq mm
90.12.7.42 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
od318019/2022_2023 : Supply, Installation, Testing and commissioning of PLC system with relay operation for the automatic operation of DG set with 2 EB supply control circuit. with necessary equipment's and protection circuit (MCB, SMPS and other relay like over/under current) (Make : Delta PLC, Siemens, Schneider)
od318020/2022_2023 : Supply and installation of 4 pole FN type 200 A isolator in the existing panel board with necessary equipment's for connecting. (L&T, C&S or other reputed brands)
od318021/2022_2023 : Supply, installation of DG exhaust piping, Thermal insulated exhaust with resin bonded glass wool having density of 32 kg/m3 or equivalent fixed on the existing DG exhaust of 60 - 100 KVA DG set for thermal insulation and each layer covered by a layer of chicken mesh and finally applying 0.63 mm or equivalent thick aluminum sheet cladding complete as per the site requirement and engineer direction
od319429/2022_2023 : Providing, laying and fixing following dia G.I. pipe (medium class) complete with G.I. fittings including as required<br>100 mm dia
Civil Works
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
50.6.1.1 : Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
4.1.4 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 )1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
50.10.1 : Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
50.10.2 : Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.51.1 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm)
Delstar a Grade Electrical contractors
Bidder Name
Delstar a Grade Electrical contractors
ELECTROWIND ENGINEERING CO
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_843939.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .