Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹2.4 L
EMD Value
₹4,800
Closing Date
12 Oct 2026, 6:00 pm2d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Executive Engineer PWD RandB PD III JAMMU
Office of the PWD RandB PROJECT DIVISION III JAMMU
Construction of one bed room with attached bathroom on 1st floor including other allied works in RSQ 13 at Rehari, Jammu (Electrical Works).
2026_PWDJK_327119_6
Short e-NIT No. 105 of 2026-2027 Dated 05-10-2026
Open Tender
Electrical Works
Percentage
45 days
JAMMU
Please refer Tender documents.
2 documents required · 2 mandatory
₹600
Executive Engineer PWD RandB PD III Jammu
₹4,800
Office of the PWD RandB PROJECT DIVISION III JAMMU
5 Oct 2026
5 Oct 2026
13 Oct 2026
5 Oct 2026
12 Oct 2026
5 Oct 2026
9 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point /fan point/exhaust fan point /call bell point with 1.5 sq.mm FRLS PVC insulatedc copper conductor single core cable in surface /recessed medium class PVC conduit,with modular switch , modular plate,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. | 35 | point | 1,015 | ₹35,525 |
| 2 | Supplying and fixing Suitable Size with GI Box with Modular Plate and Cover in front on surface or in recess, including providing and fixing 6 Pin 5/6 and 15/16 A Modular Socket Outlet and 15/16 A Modular Switch, Connections etc as required | 20 | point | 586 | ₹11,720 |
| 3 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as reqired. | 20 | Each | 447 | ₹8,940 |
| 4 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface /recessed medium class PVC conduit as required "2X2.5 sq mm+ 1X2.5 sqmm earth wire. | 90 | meter. | 275 | ₹24,750 |
| 5 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in Existing surface /recessed medium class PVC Conduit as required "2X4 sq mm+ 1X4 sqmm earth wire. | 60 | Mtr | 334 | ₹20,040 |
| 6 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in Existing surface /recessed medium class PVC Conduit as required "2X10 sq mm+ 1X6 sqmm earth wire. | 30 | Mtr | 570 | ₹17,100 |
| 7 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required of Approved brand. 1 x 1.5 sq. mm | 90 | Mtrs. | 45 | ₹4,050 |
| 8 | 1x 2.5 sq. mm | 90 | Mtrs. | 49 | ₹4,410 |
| 9 | 1 x 4 sq. mm | 90 | Mtrs. | 74 | ₹6,660 |
| 10 | Supplying and fixing 5 amps to 32 amps rating 240/415 volts "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required of Approved Brand. Single Pole | 9 | No. | 256 | ₹2,304 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.74 MB
BOQ_1106655.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .