Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹20.8 LAccepted-AOC | 1 | Accepted-AOC Lowest and eligible bidder | |
| 2 | 2₹21.3 L+₹45,070.80 (2.16%)Rejected-Finance | 2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | 3₹21.4 L+₹52,701.80 (2.53%)Rejected-Finance | 3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | 4₹21.8 L+₹97,504.80 (4.68%)Rejected-Finance BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | 4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | 5₹22.1 L+₹1.2 L (5.77%)Rejected-Finance 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | 5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹44,000
Closing Date
6 Jan 2021, 6:00 pmClosed
Garrison Engineer Kota
Opp Circuit House, Station Road, Kota - 324001
SPECIAL REPAIR/REPLACEMENT OF LT ELECTRIFICATION AND ALLIED WORKS AND CERTAIN OTHER SR AND REVENUE WORKS UNDER AGE E/M AT MILITARY STATION KOTA
2020_MES_404717_1
8485/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
Kota
Class E category b(i)
8 documents required · 8 mandatory
₹500
GE Kota
₹44,000
Yes
14 Jan 2021
18 Dec 2020
8 Jan 2021
18 Dec 2020
6 Jan 2021
1 Jan 2021
19 Dec 2020 - 24 Dec 2020
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for reuse or for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Dismantling unserviceable main switch/DBs incl wooden board and deposit to MES store yard including making good disturbed surface of wall complete all as specified and directed.
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed sufaces to match with the existing surface, complete all as specified and directed.
Disconnecting and taking down carefully old ceiling fan/exhaust fan and refixing the same after cleaning etc, complete all as specified and directed.
M&L for Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less then 20 mm width including all accessories, fixed on surface including making good disturbed surfaces, complete all as specified and directed for the following: - One light/fan/bell buzzer point controlled by one, one way switch of 5/6 Amps.
One 3 pin 5 Amp socket outlet point on the same board with other switches.
One 3 pin 5 amps socket outlet point on independent board.
One light point controlled by two, 2-way switches of 5/6 amps.
M&L Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 2.5 Sqmm, with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable FRLS of size 2.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less than 20 mm width with all accessories and fittings, fixed on surface for one socket outlet 15 amp on independent board including making good disturbed surface, complete all as directed and specified.
S&F switch piano flush type 5/6 Amps, 230 volts, single pole, one way, complete all as specified and directed.
S&F switch socket combination, 5 and 15 Amps, 230 volts, multi pin, flush type, universal, complete all as specified and directed.
S&F switch piano flush type 5/6 Amps, 230 volts, single pole, 2 way, complete all as specified and directed.
S&F switch socket combination, 5/6 Amps, 230 volt, multi pin, flush type, universal, complete all as specified and directed.
S&F socket outlet, 5/6 Amps, 230 volt, multi pin, flush type, universal, complete all as specified and directed.
S&F Lamp Holder (ISI Marked) PVC/Polycarbonate body with back plate, suitable for batten fittings, complete all as specified and directed.
S&F Ceiling rose, surface bakelite, 65x20 mm, three terminal, complete all as specified and directed.
S&F Call bell AC 230 Volts, single pole, ding dong sound, complete all as specified and directed.
S&F bell push piano, flush type 5/6 Amps, 230 volts AC,single pole, complete all as specified and directed.
S&F stepped type electronic fan regulator, flush type, 230 volts AC, single pole, humming free, fixed on the existing phenolic laminated sheet, complete all as specified and directed.
M&L for Sub main wiring power/circuit using PVC insulated (FRLS) unsheathed, stranded copper conductor cable, 2 Single core of size 4 Sqmm & earth continuity conductor of size 4 Sqmm, to be drawn through and including PVC conduit of dia not less than 25mm, medium grade, fixed on surface of walls/roof/floors, complete all as specified and directed.
M&L for Sub main wiring power/circuit using PVC insulated (FRLS) unsheathed, stranded copper conductor cable, 2 Single core of size 6 Sqmm & earth continuity conductor of size 6 Sqmm, to be drawn through and including PVC conduit of dia not less than 25mm, medium grade, fixed on surface of walls/roof/floors, complete all as specified and directed. Note for sub main wiring: - (i) Two runs of sub main wire, one run of earth wire and one run of PVC conduit shall be measured as one unit.
S&F wall mounted LED Tube light fittings, batten type with bipin holders, powder coated steel with retrofit 20 watt LED tube, internally prewired, complete all as specified and directed.
S&F LED security light fitting, 36 watt, pressure die cast aluminium housing with IP 66 deg of protection, complete with 1.20 m long street light bracket made of 40 mm bore GI light grade tubing including necessary clamps, nuts, bolts, washers etc, complete all as specified and directed.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one SP MCB of 32 Amps, complete all as specified and directed.
S&F MCB TPN DB made of sheet steel, phosphatised powder painted, with neutral bus bar 200 A, neutral link, IP-43-IK09 protection grade, 415 Volts AC with 4 way, Double door, complete all as specified and directed.
S&F MCB DB made of sheet steel, phosphatised powder painted, with bus bar 200 A, neutral link, earth bar and Din rail, 240 Volts AC, SPN with 8 way Double door, complete all as specified and directed. Notes for MCB DB - (1) The unit rate includes for cutting the brick walls to accommodate DB flush to wall. (2) The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface.
S&F MCB SPN 240 Volts, 'B' series, breaking capacity 10 KA of rating 6-32 Amps, complete all as specified and directed.
S&F MCB SP 240 Volts, 'B' series, breaking capacity 10 KA of rating 6-32 Amps, complete all as specified and directed.
S&F MCB TPN, 63 Amps, 415Volts, breaking capacity 16KA, 'B' Series, complete all as specified and directed.
M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized earth lead wire of 4 mm dia by means of bolts, buts, check nuts and washers of galvanized iron on steel including 15 mm bore light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm bore, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including GI wire of 4 mm dia for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 3 and complete all as specified and directed. (Earth lead wire and GI protection pipe beyond 7.50 m shall be measured and paid separately)
M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized earth strip of 25x4 mm dia by means of bolts, buts, check nuts and washers of galvanized iron on steel including 40 mm bore light grade GI tubing for protection of earth strip, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm bore, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including GI earth strip of 25x4 mm size for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 3 and complete all as specified and directed. (Earth lead strip and GI protection pipe beyond 7.50 m shall be measured and paid separately)
S & F of BEE 5 star rated Electric Water heater storage type (Geyser), Glassline coated tank for protection against corrosion for longer life of heating element With 4-in-1 multipurpose valve for safety, temperature indicator dial, fire retardant cable Neon indicators for 'Power on' & 'heating' functions supplied and installed complete capacity 25 litres storage water heater after grouting 4 Nos new bolts of required size at new/same distance in wall and tightening with nuts & washers incl extending/modifying/altering 15mm bore GI pipe line with tee, union, socket, nipple etc suitable for 15mm bore GI pipe as and where required complete connecting with chromium plated pipe (for hot water supply) and PVC flexible pipe (for cold water supply) fixed with brass check nuts & PVC flexible pipe (for cold water supply) fixed with brass check nuts & PVC washers at both ends, complete all as specified & directed.
S&F PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 100x100 mm and 50 mm deep, complete all as specified and directed.
S&F PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 175x100 mm and 50 mm deep, complete all as specified and directed.
S&F PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 200x150 mm and 50 mm deep, complete all as specified and directed.
S&F PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 250x200 mm and 50 mm deep, complete all as specified and directed.
S&F ceiling fans of 1200 mm sweep including all accessories such as down rod, canopy, blade set comprising of three blades, hanging arrangement with rubber block, nuts, bolts, washers, split pins, capacitor etc complete with and including PVC insulated twisted twin core 23/0.0076 copper conductor flexible rubber insulated cable of required length from connector/ceiling rose to fan motor including testing, commissioning and painting with black synthetic enamelled paints MES number upto 2.5 cm high, complete all as specified and directed.
S&F Exhaust fan of size 300mm sweep, 1400 RPM, metal body, complete with condenser and mounting from and regulator including providing/cutting the round hole of required size in the wall finishing the same supply and grouting the ragged bolt in wall, fixing the frame and exhaust fan including supply and fixing the louver shutter with frame on the exhaust side (outer surface of the wall) and connecting PVC insulated twisted twin core 23/0.0076 copper conductor flexible PVC insulated cable of required length from connector/ceiling rose to fan motor and engraving and painting with black synthetic enamelled paint MES number upto 2.5 cm high including testing and commisioning, complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m deep for foundation etc or for shafts, column footings or for laying cables, pipe lines etc not exc 10 Sqm on plan and getting out in any type of soil, complete all as specified and directed.
Returning filling in soil including spreading, leveling, watering and well ramming in layers not exc 25 Cm, complete all as specified and directed.
Removing excavated materials (soil) not exc 50 m distance and depositing where directed at a level not exc 1.5 m above starting point, complete all as specified and directed.
M&L dry clean Sand filling in trenches around underground cables for earth cushion, complete all as specified and directed. (Depth of sand shall be measured after punning).
M&L for pulverized fuel Ash-lime bricks (Fly ash bricks - non modular size), class 10, laid dry and flat adjoining each other over sand cushion in trenches as protection to UG cable, complete all as specified and directed.
M&L 40 mm bore Steel water tubing, light grade, galvanised, with all fitting, laid in trenches/fixed to walls/poles etc as protection to cables, with and including necessary MS clamps, nuts botls, washers etc required for fixing, complete all as specified and directed.
M&L 50 mm bore Steel water tubing, light grade, galvanised, with all fitting, laid in trenches/fixed to walls/poles etc as protection to cables, with and including necessary MS clamps, nuts botls, washers etc required for fixing, complete all as specified and directed.
M&L for cutting of existing floor/road of interlocking tiles or any other type for laying of cable through GI pipe, including making good of surface after laying of pipe as per existing finish, complete all as specified and directed. (GI pipe shall be measured and paid separately.)
Taking down or dismantling ACSR conductor carefully, complete all as specified and directed.
Taking down or dismantling existing old unsv cross arms of MS channel or angle sections etc., complete all as specified and directed.
Taking down old unserviceable PCC pole and Supply, transporting, erection and fixing steel tubular swaged pole, 9.00 metres long, type 410 SP-31, complete with cast iron base plate, pole cap, finial taper plug, bolts, nuts, washers etc including necessary earth work and excavation, PCC in foundation 1:3:6 type C2, using 40 mm graded stone aggregate and PCC 1:2:4 type C2, using 40 mm graded stone aggregate as in plinth block, disposal of surplus soil to a distance not exceeding 50 m, painting the pole with two coats of aluminium paint over one coat of red oxide primer including 3 nos band/straps with red post office box colour (300mm wide each) synthetic enamelled paint at a distance 300mm from plinth block and marking pole nos with black synthetic enamelled paint including tarring one coat on steel surface embedded in concrete, complete all as specified and directed.
Supply, laying and testing LT 1100 volts grade UG cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe etc, complete all as specified and directed for the following size of cables:- (a) 50 Sqmm 3.5 core
(b) 25 Sq mm 3.5 core
(c) 10 Sq mm 2 core
Supply, installing, commissioning and testing outdoor type feeder pillar box factory made (CPRI approved manufacturer), structure fabricated from 3.15 mm thick CRCA sheet, compartmentalized design of suitable size with opening from front and back including mild steel channel frame of ISMC 75 at the base of panel only for grouting purpose, and grouted in PCC 1:2:4 type B-1 using 20mm graded stone aggregate. The panel shall be dust & vermin proof by providing good quality gasket on doors removal covers, gland plates etc including all internal connections with 4 Nos heat shrink insulated aluminum bus bar of 400 ampere rating. The sheet metal work of the panel shall have powder coated finish internally and externally. The panel shutter / doors shall be provided with detatchable & flush type hinges including flush cylindrical locks. Provision for cable entry shall be from either side. All joints and connection shall be done by galvanised or cadmium plated high tensile nuts, bolts and washers. The panel shall be provided and complete with the following accessories: -
Supply and fixing 70/72 watt energy saving long life versatile roadway luminaire with pressure die-cast aluminium housing and toughened glass cover with IP 66 protection, with high power LED as light source including electronic driver and all accessories, complete all as specified and directed including disconnecting and taking down existing street light fitting of any type.
M&L for disconnecting and taking down street lights including GI pipe brackets from Poles/walls upto 9 m high and refixing in same /other position after cleaning etc, complete all as specified and directed.
Taking down old unserviceable/rusted GI pipe bracket on pole/building and S&F 32 mm bore light grade GI pipe bracket, 1.50 m long, bent to shape as required, fixed on pole/building with and including suitable mild steel flat iron clamps with required, nuts, bolts and washers, complete all as specified and directed.
Taking down old unserviceable/rusted GI pipe bracket on pole/building and S&F 40 mm bore light grade GI pipe bracket for mounting two street lights, 1.50 m long, bent to shape as required, fixed on pole/building with and including suitable mild steel flat iron clamps with required, nuts, bolts and washers, complete all as specified and directed.
S&F junction box made out of 2 mm thick CRCA sheet of size 250x250x150 mm with hinged door and locking arrangement including aluminium bus bar of size 25x3 mm three phase & neutral fixed on insulator including 01 No. MCB SP 6 Amps & painting the box with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
S&F PVC insulated 1.50 Sqmm, single core multistranded copper conductor cable, unsheathed, 1100 volts grade, drawn through existing conduit / casing capping concealed or on surface/pole/wall including taking down existing unserviceable wire, complete all as specified and directed.
Material and labour for street light timer boards (Astronomical type) 32 Amps, 3 pole, 230 Volts, suitable for out door operation including astronomical time switch infrared sensor for automatic operation of lights as per seasonal variation of daylight, relay, MCB etc, complete all as specified and directed.
S&F 20 mm bore GI tubing, medium grade, with all fittings and fixed complete to walls, ceilings and floors, complete all as specified and directed.
S&F 20 mm bore gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
S.S Enterprises
SARDAR PATEL ENTERPRISES
RAHUL ENTERPRISES
Pioneer Enterprises
TARKESHWAR DASS CONSTRUCTION COMPANY
K B ENTERPRISES
M/s Prem Associates
SINGH ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .