| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.3 LAccepted-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹49.3 L+₹2.0 L (4.14%)Rejected-Finance KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹50.2 L+₹2.9 L (6.05%)Rejected-Finance | L3 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
30 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Manish Kumar, IDSE, Garrison Engineer
GE Navy Porbandar Tija Mile Porbandar
PROVN OF CERTAIN SANCTION WORKS AT INS DWARKA OKHA UNDER GE NAVY PORBANDAR
2023_MES_635115_1
8836/OKHA/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Porbandar
PLEASE REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹94,000
Yes
22 Feb 2024
30 Dec 2023
2 Feb 2024
30 Dec 2023
30 Jan 2024
16 Jan 2024
30 Dec 2023 - 15 Jan 2024
Amount
Design, supply, erection, installation, Commissioning and testing of OFF GRID Solar Power Plant of 10 KW capacity including mimimum 325 WP poly crystaline Silicon photovoltic module of panel efficiency not less than 15%, maintenance battery with gel technology tubular with 5 year Warranty including 26Nos of 200 AH each for back up, with power evacuation at 415V, 3 Phase 4 WIre system array junction boxes comprising of following sub components / sub systems and meeting the specifications as given subsequently and complete all as specified and directed by Engr-in-Charge. PV MODULES :- To obtain 10 KWp minimum required numbers of crystalline silicon solar PV modules not less than 325 Wp each having efficiency more than 16% at standard test conditions, fill factor more than 0.75 plant performance ratio more than or equivalent to 75% in accordance with IEC 61724 & made of high transmittivity glass and glass front surface shall give high encapasulation gain (transmittance above 90% and bending less than 0.3%) Electrical parameters of 325 Wp solar PV module under STC of irradiance 1000 W/m2. AM 1.5 Spectrum & temperature 250 C will be as under :- Max Peak Power Pmax > 325wp / Current at Pmax pm 8.601 A Voltage at Pmax Vpm 37.828 volt / Short Circuit current Isc 9.268A Open circuit voltage Voc 46.79 Volts Note : (a) Solar module and SPV cells used in the module should essentially be indigeneously manufactured in india. (b) PV Module shall be warrented for a minimum 25 years. (c) PV modules shall be warrented for their output peak watt capacity which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (d) PV module shall be tested by any MNRE approved laboratory.
(e) Rated output of modules shall have positive tolerance of 3-5% & no negative tolerance is allowed (f) It shall perform satisfactorily in relative humidity 85+ 5% with temperature -100C to 850C (Cell) and should withstand wind 150 Km/Hr on the surface of the panel. (g) PV modules must be warranted for their output peak watt capacity, which shall not be less than 90% of the initial value at the end of 10 years and 80% of the initial value at the end of 25 years. (h) Each module shall have RFID tag encapsulated with Solar Cells bearing the following details RFID reader will be provided by contractor :-
(j) Name of manufacture of PV Module (ii) Name of manufacturer of solar Cell (iii) Month and year of manufacture (Separated for cell & module) (iv) Country of orgin (separately for solar cell & module) (v) Peak wattage Im Vm and fill factor of the module (vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate. (vii) Unique Serial No and model No of Module (viii) I-V curve of Module. (ix) Name of the test lab issuing IEC certificate. (x) Other relevent information of tracebility of solar cells and modules. (k) The temperature co-efficient for the module shall not be more than 0.50%/0c (l) Every module must have by pass diode of suitable capacity (m) PV module must conform to latest edition of IEC 61215/IS14286 in addition the modules must conform to IEC 61730 Part I & II for construction and testing & safety qualification & conforming to IEC 62804 PID & IEC 61701/BIS61701 for corrosive atmosphere. (n) It shall also in conformity of latest minimum technical specifications issued by MNRE from time to time. Modules should of 72 cells configuration and should be of MNRE approved Companies/agencies in catagory/rating SA -1A" (o) Provision of earthing & earth strip/Cables etc for earth for solar PV module structure/Array boxes etc as per latest IS/MNRE norms to be provided and the cost of the same is to be included in this item and no extra amount will be paid to the contractor on this account.
Junction Boxes:- Supply suitable Numbers (as per design) of 12/16/24 Inputs and suitably rated output having separate DC fuses for both (+) and (-) on input and Isolator on output terminal for each string. Each Junction Box should have on spare input terminal SMB should have RS -485 communication port to read individual string Current .Bus Voltage and Inside Tempreture Dust Vermin and waterproof Array Junction Boxes of FRP/thermo Plast with IEC62208 and shall be sunlight/UV resistant a well of fire retardant including over voltage protection, surge protection and maintenance free earthing and earthing free strip as per relavant standard. The PV module must be tested and approved by one of the IEC authorised test centres in addition a PV module qualification test certificated as per IEC standard issued by ETDC NABL accredited lab (1) MODULE MOUNTING STRUCTURE (MMS) (a) MMS should be made with hot dipped galvenised iron section , galvanisation not less than 85 micron. (c) Confirming to IS 2061-1992 and galvanized as per IS 4759. (d) The material shall be corrosive resistant and electrically compatible with material used in module frame. (e) The minimum clearance of the structure from ground level should be 300-400 mm. INVERTER - Electronic inverter with associated controls protection device. It should also have MPPT (max power point tracking) or interface between solar PVC and the invertor. Earthing of inverter included in this+B17 item. Invertor shall confirm the following parameter :- (i) Output Power -10 KW (ii) Output Voltage - 415 (iii) output frequency -50Hz (iv) Total harmonics distrotion < 5% (v) Max output current - 100 A/50A (in case of 30 Kw) Note :- 1-contractor may offer 2 nos of inverter combine power of 10 KW as per design approval.
2- Inverter shall have all necessary accessories required for connection of out put to existing LT panelCHARGER DC OUTPUT :- (a) Max out put charge current 16 A or as per manufacture recommendation. (b) Output charger Voltage Range 96-114 V or as per manufacture recommendation. (c) Charge control three stage two stage boost custom (d) Charge temperature compensation battery temp sensor included. (e) Power factor corrected changing 0.98. (f) Compatible battery type flooded, GEL AGM, LION, Coustom (g) Efficiency peak 95.7%. General Specification : IP degree of protection IP55, warranty 2 year. BATTERY : 26 (Twenty Six) Nos Gel Technology tubular solar batteries 200AH 12 V for back up with MS stand shall be provided in configuration as specified and directed by Engr-in-Charge. DC COPPER CABLE- From module to SMB and SMB to Inverter as per design included in the item and as per site requirement. Note :- (a) Module should be make in India (b) Qualifies under the domestic content requirement norms as per specification. (c) All mechanical and electrical works shall be carried out as per relevent BIS IS equivalent standard norms only and also in accordance with the latest edition of the indian electricity Act rules formed there is under and as amended from time to time. (d) Submitting completion Drgs & Test certificates for all major eqpt Catalogue, gaurantee, warrenty certificate to be submitted. (e) Any minor items inescapable required at site which are essential should be deemed to be included in the quoted rate of respective items. (g) All the item used in Solar power plant should be MEDA/MNRE Approved. (h) Battery should be arranged properly in MS Frame duly painted. (j) Warranty (k) The overall workmanship of the grid solar power plant and MMS must be given a warranty for a minimum of 5 years. (l) The Solar power plant to be tested before completion by Engineer-in-Charge for parameters specified above.
M&L for Earthing complete with copper earth plate electrode 60cmx60cmx3.15mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level earth plate connected with copper strip 20x3mm by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel, GI protection pipe 25mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around copper earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover including testing on completion complete all as specified and directed.
Supply and fixing of MCB DB Single pole and neutral 8 way double door 230V having earthing terminal including making electrical incoming and outgoing connection complete all as specified and as directed.
Supply and fixing of changeover MCB SPN 63Amps,10 KA breaking capacity 230 V,50 Hz for lighting and other domestic load complete all as specified and directed.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 10 sq mm, 3 core, 1100 Volts grade oassing through 20mm dia PVC conduit complete all as specified and directed by Engineer - in - Charge.
Supply and Laying in trenches or passing through pipe, LT XLPE cable with stranded aluminium conductor heavy duth for 1100 volts grade 25 Sqmm 4 Core cross sectional area .
M & L for Sand cushioning with a layer of sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed.
M & L for Unreinforced precast concrete cable cover, ISI marked class LV types 2 flat size 250mm x 150mm x 40mm having minimum average breaking load 200Kg, complying IS:5820-1970 made of concrete used of grade M-20, laid flat in trenches over the cable with the length of concrete cover perpendicular to the direction of the cable length, adjacent / abutting each other complete all as specified.
M & L for Galvanised tubing light grade 40 mm nominal bore for passing of cable, fixed to poles / walls / laying under floor/ roads complete with and including fittings, clamps nut bolts as required complete all as specified and as directed.
S & F CPVC Ball valves, suitable for 40 mm dia for CPVC pipe complete with all jointing materials etc. all as specified and directed.
S & F CPVC Ball valves, suitable for 25 mm dia for CPVC pipe complete with all jointing materials etc. all as specified and directed.
Supply, Testing and Commissioning of openwell submersible monoblock pump set min 2 HP capacity with 500 LPH at 30M head capacity with necessary accessories in delivery line i.e.CPVC Pipe of suitable length and pressure rating 10 Kgf/Sqcm of size 20 mm dia bore up to top surface of well, suction stainer, DOL Starter suitable rating fixed at position in or near the proposed main supply with necessary fixing accessories and enclosure, submersible flat cable 4.0 Sqmm size( minimum 25 meter) from starter to submersible pump with necessary protection by CPVC pipe upto tank, Nylon rope for securing the pump all as specified and as directed Make: CG/Kirloskar or Equivalent
S & F Ball valves of size 25 mm dia with high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20 mm - 210 gms / 25mm-455gms/ 40mm - 690 gms) as directed by engr - in - charge.
S & F of solar panel cleaning sprinkler shower pvc set is fixing of 20 mm UPVC pipe complete all as specified and directed by Engr - in- Charge.
M&L for Rendering 10mm thick in CM 1:4 on fair faces of on stone masonry surfaces or surface other than fair face of stone-work wall surface to be finished even and smooth without using cement on fair faces of stone wall all as specified and as directed.
M & L PCC ( 1:3:6) type C1 with 20 mm graded aggregrate for coping of pole, tank foundation, foundation for SPV panel etc including necessary form work for water supply stand post all as direcetd by Engr - in - Charge.
Supply and Fix Star delta Starter fully automatic suitable for 415 V AC 15.0 HP complete all as specified and as directed.
Supply and fixing Monoblock pump set suitable for 415 V, 3 phase system minimum 3000 RPM, having capacity 15.0 HP, copper wounded, made up of cast iron impeller, SS shaft, Cast iron metal body, star-Delta based, IP-55 protection, suction delivery head 100mm dia, class 'B' / 'F' insulation self priming monoblock pump set including all fixing accessories with making PCC foundation for pump complete all as specified and as directed.
Supply and lay pipe galvanized, “Medium class”, including fittings 100 mm (4”) dia complete all as specified and as directed.
Supply and lay pipe galvanized, “Medium class”, including fittings 80 mm (3”) dia complete all as specified and as directed.
Supply and fix Valves, Sluice, flanged of class 1.6 PN but 100 mm (4”) dia complete all as specified and as directed.
Supply and fix Valves, Sluice, flanged of class 1.6 PN but 80 mm (3”) dia complete all as specified and as directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m deep and getting out for taking out/laying of water supply pipe line.
Returning and filling in trenches incl spreading, levelling watering and raming in layer n.exc 25 cm complete all as specified and directed.
Removing of excavated mtrls n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point.
M&L for valve camber of size 1000 mmX1000 mmx1000 mm (internal dimation) with sub class 'B' brick masonery built in cm 1:6. 10cm thick internal & 10mm thick external plaster in 1:4 cm provided with 3mm thick ms sheet cover welded 40x40x3mm ms angle iron frame fixed in coping PCC 1:2:4 type B1 ( using 20mm graded stone aggregate ) with locking arrangement and handel, painting with two coat of red oxide and two coats of synthetic enameled red paint over one coat of red oxide primer complete inculiding excavation and earth work all as sepcified and directed.
M&L for Cement Plaster 1:3 for repairing of plaster work with integral water proofing compound in mortor (as/if required), complete all as specified and as directed.
Supply and Laying of 10 Sqmm 3 core electric supply cable PVC insulated, PVC round sheathed multicore industrial copper conductor cables for voltage grade upto 1100 V passing through PVC conduit on surface with the help of suitable saddle/clamps complete with copper lugs all as specified and directed by Engr-in-charge.
Supply and fix Non return Valve 100 mm complete all as specified and as directed.
Supply and fix Non return Valve 80 mm complete all as specified and as directed.
Taking down carefully aluminum/copper point wiring (light,fans,socket etc) complete incl battens and fittings such as switch, ceiling rose,light fittings, regulaters, socket etc and making good disturbed surface of wall/floor etc complete all as specified.
Material and labour for point wiring with 2.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly drawing into and including rigid non-metallic PVC conduit of 25 mm dia or higher, medium grade complete with and including all PVC conduit accessories by cutting of chases in wall/roof/floors concealed in walls/roof/floors with MS sheet metal/PVC sunken modular switch/Terminal box 1.2 mm thick and Modular plate and screws with cup washers all as directed and specified Note : (1) Rate is inclusive of Cutting/chases of wall/floor/ceiling and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc suitable for Mylinc / Coral / Sleek model accessories etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for 15 amps switch socket combination outlet on independent board complete all as specified and directed.
Supply and Repair/Replacement of for Modular switch 1 way 16 Amps, 1 modules 230 volts Complete all as specified and directed.
Supply and Repair/Replacement of Modular socket 6A/16A, 2/3 pin combined, 2 modules 230 volts complee all as specified and directed.
Supply, installation, commis-sioning of Water cooler fully stainless steel, electric driven single phase having approx storage capacity 80 Ltrs and nominal cooling capacity 40 Litres per hour.complete all as specified and as directed.
Supply, installation, commis-sioning of Water cooler fully stainless steel, electric driven single phase having approx storage capacity 120Ltr and nominal cooling capacity 60 Litres per hour.complete all as specified and as directed.
Supply, installation, commis-sioning of Water cooler fully stainless steel, electric driven single phase having approx storage capacity 120Ltr and nominal cooling capacity 150 Litres per hour.complete all as specified and as directed.
Supply and fix water cooler electric driven (single phase), having approx storage capacity of 400 litres and nominal cooling capacity of 200 Litres per hour.complete all as specified and as directed.
Supply and fix refrigerator, electric driven (single phase), capacity 165 Litres .BEE 5 star rated complete all as specified and as directed.(Samsung/LG/Whirpool).
Supply and fix refrigerator, electric driven (single phase), capacity 260-310 Litres.BEE 5 star rated complete all as specified and as directed. (Samsung/LG/Whirpool).
Supply and fix refrigerators, electric driven (single phase), capacity 315 Litres .BEE 5 star rated complete all as specified and as directed. (Samsung/LG/Whirpool).
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA complete all as specified and as directed.
Dismentling /Removing and deposite to MES Store of the existing Water Cooler and Refrigerator of any size complete all as specified and directed Engr-in-charge.
Supplying and laying testing of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches with fittings and fixtures complete all as specified.all as directed by Engr in charge. For the following sizes.
50 mm dia
40 mm dia
25 mm dia
20 mm dia
16 mm dia
Making connection of PP-R/GI distribution branch with CPVC main outer dia of pipe 50 to 75mm by providing and fixing tee including cutting and making fusion joint etc. complete all as specified.all as directed
Supply & Fixing of Rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) of capacity 2000Ltr hoisted and fixed in position on foundation all as specified in SSR Part I complete all as specified.all as directed by Engr in charge
M&L for Cement Concrete 1:4:8 (40mm Graded Stone Aggregate) as in Foundation of Poles, Stays, etc. including Formwork (as/if required), complete all as specified and as directed.
M & L brick work with sub class 'B' bricks in cement mortar 1:6 complete at various locations all as directed
Supply and fixing , testing of CPVC gate valve with complete fitting . All as directed by engr-in- charge. Size 16 / 20 mm dia.
Supply and fix 16 mm dia irrigation flexible pipe (300 mtr long roll).
Supply and fix 16 mm dia irrigation T Connector (50 nos packet)
Supply and fix drip irrigation stand.(12 Nos packet)
Supply and fix drip irrigation plant water dripper. (25 Nos packet)
Supply and fix drip irrigation plant water Elbow. (50 Nos packet)
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of 2 TR capacity complete all as specified andas directed.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of 1.5 TR capacity complete all as specified andas directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA complete all as specified.
Supply and fix of DBOXx MCB Protected Socket with Sheet steel Enclosure single pole 20 Amp with 3 pin plug top for AC connection from Socket point to stabilizer complete all as specified and directed by Engineer - in - Charge.
Supply and Fix of MCB rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP of 32Amp current carrying capacity in the MCB DB complete with connection testing and commissioning.complete all as specified and directed by Engineer - in - Charge.
M&L for Sub main wiring for AC point using PVC insulated unsheathed FRLS, stranded copper conductor cable 2 Single core of size 4 Sqmm FRLSH cable earth continuity conductor of size 4 Sqmm to be drawn through in and including surface PVC casing caping on walls/roof/floors all as directed by Engineer in Charge. Notes:- (i)Two wires of 4 sqmm and one wire of 4 sqmm & PVC conduit shall be measured as one unit.
JAY BHARAT METAL SUPPLIERS
BABUBHAI BHIMABHAI PANDAVADRA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .