Loading…
Loading…
Tender ID
Tender Value
₹72.9 L
EMD Value
₹1.5 L
Closing Date
24 Mar 2026, 10:00 amClosed
Executive Engineer Const Div No. 1 PWD Ludhiana
Executive Engineer Const Div No. 1 PWD Ludhiana
CONSTRUCTION OF AUDITORIUM AT DIET BUILDING JAGRAON DISTT. LUDHIANA
2026_CEPW_163643_1
27 of 11.03.2026 DIET
Open Tender
Civil Works - Buildings
Percentage
120 days
JAGRAON
Please refer Tender documents.
23 documents required · 23 mandatory
₹20,000
₹1.5 L
Yes
24 Mar 2026
13 Mar 2026
24 Mar 2026
13 Mar 2026
24 Mar 2026
13 Mar 2026
Select, At Par, Excess (+), Less (-) IOCL
Tender Inviting Authority: EXECUTIVE ENGINEER, CONSTRUCTION DIVISION NO.1, PWD B&R BR., LUDHIANA
Name of Work: DNIT FOR CONSTRUCTION OF AUDITORIUM AT DIET BUILDING JAGRAON DISTT. LUDHIANA
Name of the Bidder/ Bidding Firm / Company :
S. No. Item Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres BI01010001010000000000000515BI0100001114 0.7600 cum 0.999 Excess(+) Full Conversion INR
Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter ( width - 300 mm, depth - 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm. BI01010001010000000000000515BI0100001115 ltr Excess(+) Full Conversion INR
Cement Concrete 1:4:8 with stone ballast of size. Using concrete mixer volumetric type. BI01010001010000000000000515BI0100001116 cum Excess(+) Full Conversion INR
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) BI01010001010000000000000515BI0100001117 sqm Excess(+) Full Conversion INR
Centering and shuttering for columns (Square or rectangular or poly gonal in plain) BI01010001010000000000000515BI0100001118 sqm Excess(+) Full Conversion INR
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. BI01010001010000000000000515BI0100001119 cum Excess(+) Full Conversion INR
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth BI01010001010000000000000515BI0100001120 cum Excess(+) Full Conversion INR
Damp proof course 4 cm thick of cement concrete 1 : 2 : 4 with 2 coats of bitument 20/30 penetration at 1.65 kg per Sqm. laid hot and sanded. BI01010001010000000000000515BI0100001121 sqm Excess(+) Full Conversion INR
Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. BI01010001010000000000000515BI0100001122 sqm Excess(+) Full Conversion INR
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. BI01010001010000000000000515BI0100001123 sqm Excess(+) Full Conversion INR
Extra rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof. BI01010001010000000000000515BI0100001124 sqm Excess(+) Full Conversion INR
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. BI01010001010000000000000515BI0100001125 cum Excess(+) Full Conversion INR
Extra for c above 4 meters (where any single storey exceeds 4 metres in height) for every additional height of 2 metres or part thereof for Brick Work/ Concrete Block/ Clay Block. BI01010001010000000000000515BI0100001126 cum Excess(+) Full Conversion INR
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1 :4 cement sand mortar in super structure. BI01010001010000000000000515BI0100001127 sqm Excess(+) Full Conversion INR
Extra for 115mm/100mm thick of walls done above 4 meters (where any single storey exceeds 4 meters in height) for every additional height of 2 meters or parts thereof for Brick Work/ Concrete Block/ Clay Block. BI01010001010000000000000515BI0100001128 sqm Excess(+) Full Conversion INR
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure BI01010001010000000000000515BI0100001129 cum Excess(+) Full Conversion INR
Extra for RCC/PCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof. BI01010001010000000000000515BI0100001130 cum Excess(+) Full Conversion INR
Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the same shall be deducted ) BI01010001010000000000000515BI0100001131 cum Excess(+) Full Conversion INR
Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC) BI01010001010000000000000515BI0100001132 cum Excess(+) Full Conversion INR
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.0 works, where not including in the complete rate of RCC including bending and binding placing in position complete BI01010001010000000000000515BI0100001133 Qntl Excess(+) Full Conversion INR
Extra for work done in each subsequent storey above the first storey for item No. 18.17, 18.18, 18.19-For first floor BI01010001010000000000000515BI0100001134 Qntl Excess(+) Full Conversion INR
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres BI01010001010000000000000515BI0100001135 cum Excess(+) Full Conversion INR
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres BI01010001010000000000000515BI0100001136 cum Excess(+) Full Conversion INR
Base course of floor consisting of 100mm thick cement cocrete 1:8:16 and 100mm sand or stone filling. BI01010001010000000000000515BI0100001137 sqm Excess(+) Full Conversion INR
10mm thick Cement Plaster 1:4 BI01010001010000000000000515BI0100001138 sqm Excess(+) Full Conversion INR
12.5mm thick cement plaster 1:5. BI01010001010000000000000515BI0100001139 sqm Excess(+) Full Conversion INR
20 mm thick cement plaster 1:5 in two coats work. BI01010001010000000000000515BI0100001140 sqm Excess(+) Full Conversion INR
Extra for Plastering in each subsequent storey above the first storey upto 4 metre above plinth level-First floor BI01010001010000000000000515BI0100001141 sqm Excess(+) Full Conversion INR
Extra for Plastering where any single storey height exceeds 4 metres in height for every additional height of 2 metres or part thereof.(Internal or External) BI01010001010000000000000515BI0100001142 sqm Excess(+) Full Conversion INR
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) BI01010001010000000000000515BI0100001143 sqm Excess(+) Full Conversion INR
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001144 sqm Excess(+) Full Conversion INR
Providing and laying flamed finish Granite stone 18mm thick in flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : BI01010001010000000000000515BI0100001145 sqm Excess(+) Full Conversion INR
Extra labour for projected nosing of stair case any shape and design BI01010001010000000000000515BI0100001146 mtr Excess(+) Full Conversion INR
20 mm thick cement plaster in damp proof course 1:3 with two coats of bitumen 1.65 Kg. per Sqm. hot laid and sanded. BI01010001010000000000000515BI0100001147 sqm Excess(+) Full Conversion INR
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. BI01010001010000000000000515BI0100001148 mtr Excess(+) Full Conversion INR
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. BI01010001010000000000000515BI0100001149 mtr Excess(+) Full Conversion INR
Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position. (Code IS 2022-1(1999)). BI01010001010000000000000515BI0100001150 sqm Excess(+) Full Conversion INR
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash- welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items) BI01010001010000000000000515BI0100001151 kg Excess(+) Full Conversion INR
Supply and fixing glass panes with glazing clips and special metal sash puty of approved make glass panes 4mm or 10.75 kg/ sqm exceeding 0.4 sqm of area BI01010001010000000000000515BI0100001152 sqm Excess(+) Full Conversion INR
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects. BI01010001010000000000000515BI0100001153 sqm Excess(+) Full Conversion INR
Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) BI01010001010000000000000515BI0100001154 sqm Excess(+) Full Conversion INR
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : BI01010001010000000000000515BI0100001155 nos. Excess(+) Full Conversion INR
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : BI01010001010000000000000515BI0100001156 nos. Excess(+) Full Conversion INR
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position BI01010001010000000000000515BI0100001157 qntl Excess(+) Full Conversion INR
Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge. BI01010001010000000000000515BI0100001158 sqm Excess(+) Full Conversion INR
Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect. BI01010001010000000000000515BI0100001159 kg Excess(+) Full Conversion INR
Terracing consisting of tiles 22.86 cm x 11.43 cm x 3.81 cm laid over 25mm mud plaster, 75 mm mud filling on another layer of 25 mm mud plaster including two coats of bitumen laid hot @ 1.65 Kg. per Sqm. on top of R.C.C slab including grouting with cement sand mortar 1:4 and top surface to be left clear after wire brushing etc. BI01010001010000000000000515BI0100001160 sqm Excess(+) Full Conversion INR
extra for providing and fixing steel beeding of approved shape steel tube 12mm x 12mm BI01010001010000000000000515BI0100001161 mtr Excess(+) Full Conversion INR
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. BI01010001010000000000000515BI0100001162 mtr Excess(+) Full Conversion INR
Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 BI01010001010000000000000515BI0100001163 Nos Excess(+) Full Conversion INR
Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 BI01010001010000000000000515BI0100001164 Nos Excess(+) Full Conversion INR
P/F of PVC sheet 2mm thick (Hollow) including the cost of cutting, screw etc complete in all respects as per approved of Engineer-in-charge. BI01010001010000000000000515BI0100001165 sqft. Excess(+) Full Conversion INR
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 2.50 kgf / cm²) conforming to IS : 4985, including jointing with seal ring (i) Single socketed pipes. BI01010001010000000000000515BI0100001166 mtr Excess(+) Full Conversion INR
Providing and fixing 160 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. BI01010001010000000000000515BI0100001167 Nos Excess(+) Full Conversion INR
Providing and fixing 160 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. BI01010001010000000000000515BI0100001168 Nos Excess(+) Full Conversion INR
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. BI01010001010000000000000515BI0100001169 sqm Excess(+) Full Conversion INR
Applying priming coat with metal primer on new steel or iron work including preparation of surface BI01010001010000000000000515BI0100001170 sqm Excess(+) Full Conversion INR
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. BI01010001010000000000000515BI0100001171 sqm Excess(+) Full Conversion INR
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish BI01010001010000000000000515BI0100001172 sqm Excess(+) Full Conversion INR
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade BI01010001010000000000000515BI0100001173 sqm Excess(+) Full Conversion INR
Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm BI01010001010000000000000515BI0100001174 sqm Excess(+) Full Conversion INR
Providing and fixing false ceiling at all heights upto 4 mtr. with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6mm reveal profile (white/black),comprising of main-T runners of size 1912SUB HEAD : 26- N 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash BI01010001010000000000000515BI0100001175 sqm Excess(+) Full Conversion INR
Providing and fixing commercial plywood 12mm thick BI01010001010000000000000515BI0100001176 sqm Excess(+) Full Conversion INR
Providing and fixing ply wood, plain lining, butt jointed including PVC Plug placed at 45 cm to 65 cm centers complete with necessary nails (Frame work shall be payable extra) BI01010001010000000000000515BI0100001177 sqm Excess(+) Full Conversion INR
Providing and fixing teak wood beading to door windows chowkats with iron screws fixed in position complete as per design and shape required BI01010001010000000000000515BI0100001178 mtr Excess(+) Full Conversion INR
Spirit polishing two coats including a coat of wood filler on wood work BI01010001010000000000000515BI0100001179 mtr Excess(+) Full Conversion INR
Electrical work BI01010001010000000000000515BI0100001180
Internal E.I. Services BI01010001010000000000000515BI0100001181
RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): BI01010001010000000000000515BI0100001182
Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- BI01010001010000000000000515BI0100001183
Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. BI01010001010000000000000515BI0100001184 Each Excess(+) Full Conversion INR
RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): BI01010001010000000000000515BI0100001185
Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- BI01010001010000000000000515BI0100001186
Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). BI01010001010000000000000515BI0100001187 Each Excess(+) Full Conversion INR
RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): BI01010001010000000000000515BI0100001188
Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- BI01010001010000000000000515BI0100001189
Wiring Networking socket point RJ45 (one module) BI01010001010000000000000515BI0100001190 Each Excess(+) Full Conversion INR
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: BI01010001010000000000000515BI0100001191
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and BI01010001010000000000000515BI0100001192
Wiring fan point (With fan box) BI01010001010000000000000515BI0100001193 Each Excess(+) Full Conversion INR
Wiring light point BI01010001010000000000000515BI0100001194 Each Excess(+) Full Conversion INR
Wiring call-bell point BI01010001010000000000000515BI0100001195 Each Excess(+) Full Conversion INR
Wiring 6Amp. Plug control comprising wall socket point BI01010001010000000000000515BI0100001196 Each Excess(+) Full Conversion INR
Wiring 16/20Amp. power plug control point BI01010001010000000000000515BI0100001197 Each Excess(+) Full Conversion INR
PVC INSULATED FR COPPER CONDUCTOR CABLES: BI01010001010000000000000515BI0100001198
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- BI01010001010000000000000515BI0100001199
Overall size 1 sq.mm (Un-sheathed) BI01010001010000000000000515BI0100001200 Meter Excess(+) Full Conversion INR
Overall size 1.5sq.mm (Un-sheathed) BI01010001010000000000000515BI0100001201 Meter Excess(+) Full Conversion INR
Overall size 2.5sq.mm (Un-sheathed) BI01010001010000000000000515BI0100001202 Meter Excess(+) Full Conversion INR
Overall size 4sq.mm (Un-sheathed) BI01010001010000000000000515BI0100001203 Meter Excess(+) Full Conversion INR
Overall size 6sq.mm (Un-sheathed) BI01010001010000000000000515BI0100001204 Meter Excess(+) Full Conversion INR
Overall size 10sq.mm (Un-sheathed) BI01010001010000000000000515BI0100001205 Meter Excess(+) Full Conversion INR
Overall size 16sq.mm (Un-sheathed) BI01010001010000000000000515BI0100001206 Meter Excess(+) Full Conversion INR
XLPE INSULATED UN-ARMOURED CABLES (LOOSE): BI01010001010000000000000515BI0100001207
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- BI01010001010000000000000515BI0100001208
Overall size 70sq.mm (3½ Core) Un-armoured (Loose) BI01010001010000000000000515BI0100001209 Meter Excess(+) Full Conversion INR
HEAVY GAUGE WELDED CONDUIT PIPES: BI01010001010000000000000515BI0100001210
Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- BI01010001010000000000000515BI0100001211
Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan. BI01010001010000000000000515BI0100001212 Meter Excess(+) Full Conversion INR
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: BI01010001010000000000000515BI0100001213
Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- BI01010001010000000000000515BI0100001214
Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface) BI01010001010000000000000515BI0100001215 Meter Excess(+) Full Conversion INR
Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) BI01010001010000000000000515BI0100001216 Meter Excess(+) Full Conversion INR
Heavy Gauge PVC Conduit pipe 32mm dia. (Flushed) BI01010001010000000000000515BI0100001217 Meter Excess(+) Full Conversion INR
Heavy Gauge PVC Conduit pipe 40mm dia. (Flushed) BI01010001010000000000000515BI0100001218 Meter Excess(+) Full Conversion INR
HDPE Electrical Conduit Pipe 25mm dia. (Flushed) BI01010001010000000000000515BI0100001219 Meter Excess(+) Full Conversion INR
Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- BI01010001010000000000000515BI0100001220
PVC Flexible Pipe 25mm dia. BI01010001010000000000000515BI0100001221 Meter Excess(+) Full Conversion INR
8 SWG COPPER EARTHING : BI01010001010000000000000515BI0100001222
Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A- Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation: BI01010001010000000000000515BI0100001223
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long BI01010001010000000000000515BI0100001224 Each Excess(+) Full Conversion INR
COPPER EARTHING (Upto 14 metre in Length): BI01010001010000000000000515BI0100001225
Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- BI01010001010000000000000515BI0100001226
Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length) BI01010001010000000000000515BI0100001227 Each Excess(+) Full Conversion INR
COPPER EARTHING STRIP (As Additional Length): BI01010001010000000000000515BI0100001228
Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- BI01010001010000000000000515BI0100001229
Additional Length 20mm x 3mm thick Copper Tape BI01010001010000000000000515BI0100001230 Meter Excess(+) Full Conversion INR
Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- BI01010001010000000000000515BI0100001231
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface) BI01010001010000000000000515BI0100001232 Meter Excess(+) Full Conversion INR
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) BI01010001010000000000000515BI0100001233 Meter Excess(+) Full Conversion INR
SUPPLY AND ERECTION OF WIRING ACCESSORIES: BI01010001010000000000000515BI0100001234
Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- BI01010001010000000000000515BI0100001235
Ceiling Rose (Flush Piano type) BI01010001010000000000000515BI0100001236 Each Excess(+) Full Conversion INR
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: BI01010001010000000000000515BI0100001237
MINIATURE CIRCUIT BREAKERS: BI01010001010000000000000515BI0100001238
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- BI01010001010000000000000515BI0100001239
MCB Single Pole 6-32amp. (10kA, Curve-C) BI01010001010000000000000515BI0100001240 Each Excess(+) Full Conversion INR
MCB Four Pole 40amp. (10kA, Curve-C) BI01010001010000000000000515BI0100001241 Each Excess(+) Full Conversion INR
MCB Four Pole 50, 63amp. (10kA, Curve-C) BI01010001010000000000000515BI0100001242 Each Excess(+) Full Conversion INR
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: BI01010001010000000000000515BI0100001243
Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- BI01010001010000000000000515BI0100001244
TP&N Horizontal Double Door Distribution Board 4 way each BI01010001010000000000000515BI0100001245 Each Excess(+) Full Conversion INR
TP&N Horizontal Double Door Distribution Board 6 way each BI01010001010000000000000515BI0100001246 Each Excess(+) Full Conversion INR
Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:- BI01010001010000000000000515BI0100001247
Cable End Box for TPN 4 Way BI01010001010000000000000515BI0100001248 Each Excess(+) Full Conversion INR
Cable End Box for TPN 6 Way BI01010001010000000000000515BI0100001249 Each Excess(+) Full Conversion INR
ON LOAD CHANGEOVER SWITCH (Without Sheet Enclosure): BI01010001010000000000000515BI0100001250
Supply and erection of On Load Change over Switch with advance neutral UNIT (Panel mounting Cubical type) in the existing Cubical Panel Confirms to IS 13947 (Part-3) complete with G.I. Bolts, Nuts & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:- BI01010001010000000000000515BI0100001251
On Load Change Over Switch Four Pole 125amp., 415volts BI01010001010000000000000515BI0100001252 Each Excess(+) Full Conversion INR
LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS): BI01010001010000000000000515BI0100001253
Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55). Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. BI01010001010000000000000515BI0100001254
The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non- hygroscopic material. No live part should be in visible condition. BI01010001010000000000000515BI0100001255
Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work . Busbars:-The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. BI01010001010000000000000515BI0100001256
Metering:-The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc. Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site. Detail of capacities of MCCB's to be installed in the cubical panel Enclosure (Excluding the cost of MCCB's) as per following:- BI01010001010000000000000515BI0100001257
LT Panel enclosure having space for 1No. Incomer MCCB 160Amp. and 4Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1825 x 900 x 300mm) BI01010001010000000000000515BI0100001258 Each Excess(+) Full Conversion INR
MCCB's (FOR PANELS & SHEET ENCLOSURE): BI01010001010000000000000515BI0100001259
Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- BI01010001010000000000000515BI0100001260
MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting BI01010001010000000000000515BI0100001261 Each Excess(+) Full Conversion INR
MCCB Four Pole 125amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting BI01010001010000000000000515BI0100001262 Each Excess(+) Full Conversion INR
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: BI01010001010000000000000515BI0100001263
Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- BI01010001010000000000000515BI0100001264
Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.) BI01010001010000000000000515BI0100001265 Meter Excess(+) Full Conversion INR
Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.) BI01010001010000000000000515BI0100001266 Meter Excess(+) Full Conversion INR
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- BI01010001010000000000000515BI0100001267
Aluminium thimble cable Core size 10 -16sq.mm BI01010001010000000000000515BI0100001268 Each Excess(+) Full Conversion INR
Aluminium thimble cable Core size 25 -35sq.mm BI01010001010000000000000515BI0100001269 Each Excess(+) Full Conversion INR
Aluminium thimble cable Core size 70sq.mm BI01010001010000000000000515BI0100001270 Each Excess(+) Full Conversion INR
Supply and erection of LED batten 10watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer- in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary BI01010001010000000000000515BI0100001271 Each Excess(+) Full Conversion INR
Supply and erection of LED batten 20watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer- in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary BI01010001010000000000000515BI0100001272 Each Excess(+) Full Conversion INR
Supply and erection of LED batten 40watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer- in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary. BI01010001010000000000000515BI0100001273 Each Excess(+) Full Conversion INR
Supply and erection of LED Surface type downlighter 12watt LED (including constant LED driver) with High quality Presure die cast aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary. BI01010001010000000000000515BI0100001274 Each Excess(+) Full Conversion INR
Supply and erection of LED Recessed downlighter 18watt LED (including constant LED driver) with High quality Presure die cast aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary. BI01010001010000000000000515BI0100001275 Each Excess(+) Full Conversion INR
Supply and erection of Recessed mounted 36watt LED 2x2 panel (including constant LED driver) with CRCA sheet having with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers and hanging GI wire with top roof complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary. BI01010001010000000000000515BI0100001276 Each Excess(+) Full Conversion INR
Supply and erection of Heavy duty Exhaust Fans 300mm 900RPM with aluminium louver shutter Canon of double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. BI01010001010000000000000515BI0100001277 Each Excess(+) Full Conversion INR
Supply and erection of BEE 3-Star rating AC Ceiling Fan 1200mm (48") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 210 CMM (approx.). The rated speed of the the product must be minimum of 300 revolutions per minute and 5Nos. of speeds. The product should have a manufcaturer's guarantee/warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site. BI01010001010000000000000515BI0100001278 Each Excess(+) Full Conversion INR
Supply and erection of Wall fan 400mm Swing 16 Inch high speed including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. BI01010001010000000000000515BI0100001279 Each Excess(+) Full Conversion INR
Cost of Security Lighting BI01010001010000000000000515BI0100001280
PVC INSULATED FR COPPER CONDUCTOR CABLES: BI01010001010000000000000515BI0100001281
Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- BI01010001010000000000000515BI0100001282
Overall size 1.5sq.mm (48/0.20mm), 3Core BI01010001010000000000000515BI0100001283 Metre Excess(+) Full Conversion INR
XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): BI01010001010000000000000515BI0100001284
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- BI01010001010000000000000515BI0100001285
Overall size 10sq.mm (3Core) Un-armoured (On-Surface) BI01010001010000000000000515BI0100001286 Meter Excess(+) Full Conversion INR
AUTOMATIC VOLTAGE STABLIZER, TIMER: BI01010001010000000000000515BI0100001287
S/E of Microprocessor Based Street Light Controller with digital time switch daily programmed with stand by lithium battery with back up of 6 years with min. time between 2 switching operations is 1 minute, three pole power contactors 40A. with coil voltage 220-230V AC with 1 no. aux. contact NO, MCB 2 pole 40amp. (C-Curve, 10kA) & power wiring with single core PVC insulated FR cable 10 sq. mm and control wiring with PVC insulated FR cable 1 sq. mm, 1 no. two position selector switch to bypass timer and other accessories & petty material (din rail, 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) should be fixed on bakelite sheet 6mm thick to be mounted in a IP54 surface/ flush mounting powder coated sheet metal (1.60mm thick) cabinet having size 450mm x 600mm x 150mm to switch ‘ON’ all the 3 phases & switch ‘OFF’ 3 phases pre-fixed timings complete in all respect as per satisfaction of Engineer-in-charge:- BI01010001010000000000000515BI0100001288
Street Light Controller (For Single Phase Circuit) with 1 No. Three Pole Power Contactor 40A, 1 No. MCB 2 Pole 40amp. (C-Curve,10kA) & petty material (Din rail, 1 No. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) BI01010001010000000000000515BI0100001289 Each Excess(+) Full Conversion INR
LAYING OF UNDER GROUND CABLES, DISMANTALLING & ERECTION OF POLES AND CEMENT CONCRETE MUFFS: BI01010001010000000000000515BI0100001290
Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:- BI01010001010000000000000515BI0100001291
SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 140mm x 140mm x 95mm with hinged water tight cover with locking arrangement BI01010001010000000000000515BI0100001292 Each Excess(+) Full Conversion INR
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- BI01010001010000000000000515BI0100001293
Aluminium thimble cable Core size 10 - 16sq.mm BI01010001010000000000000515BI0100001294 Each Excess(+) Full Conversion INR
Supply and erection of LED Flood Light 120watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. BI01010001010000000000000515BI0100001295 Each Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.87 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 23.38 MB
BOQ_331391.xls
BOQ • 0.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .