Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-Finance | ₹15.8 L | L1 | Accepted-Finance Lowest Bidder |
| 2 | L2₹16.8 LRejected-Finance | ₹16.8 L | L2 | Rejected-Finance Disqualified |
| 3 | L3₹16.9 LRejected-Finance SHANTI NAGAR COLONY GAIRKATA ROAD DIST JALPAIGURI PIN 735212 | JALPAIGURI | JALPAIGURI | WEST BENGAL | 735212 | ₹16.9 L | L3 | Rejected-Finance Disqualified |
| 4 | L4₹17.1 LRejected-Finance VILLAGE BENJTABANI P O BAIDYANATHPUR DISTRICT BANKURA | BANKURA | WEST BENGAL | 722101 | ₹17.1 L | L4 | Rejected-Finance Disqualified |
| 5 | L5₹17.3 LRejected-Finance | ₹17.3 L | L5 | Rejected-Finance Disqualified |
Tender Value
₹20.3 L
EMD Value
₹40,538
Closing Date
20 Feb 2026, 3:30 pmClosed
Executive Engineer
Jalpaiguri Construction Division
Installation of Roof Truss at Second Floor at Oodlabari RH, Jalpaiguri
2026_PWD_997903_2
WBPWD/EE/JCD NIeT No 20 of 2025-26
Open Tender
CIVIL WORKS
90 days
Oodlabari
Please refer Tender details
5 documents required · 5 mandatory
₹40,538
Yes
13 Mar 2026
5 Feb 2026
23 Feb 2026
5 Feb 2026
20 Feb 2026
5 Feb 2026
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof. upto 150 mm. thick. 2nd Floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in 2nd Floor
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in 2nd floor as per relevant IS codes. (i) Pakur Variety
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. In 2nd Floor (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel. (I) SAIL/ TATA/RINL
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. In 2nd Floor
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. In 2nd floor. (i) For roof truss works. (a) Span up to 12 Mtr
Labour for assembling, hoisting, placing, fitting & fixing tubular roof trusses. (a) Above 1.5 m to 3 m span
Suppling. fitting and fixing single skin color coated trapezoidal profile for wall cladding, Roof shall be made of 0.45mm BMT (Base Metal Thickness) (0.50mm TCT (Total coated thickness excluding paint), G550 (min 550 yield strength), of Zincalume metallic coating (IS15965) with high Solar Reflectance Index (SRI) value for better colling as per thermatech technology 1000-1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg-The steel sheet shall be fastened with 40 micron zinc coated or 25 micron zinc-tin alloy coated, hex head, self-drilling screw as per IS 3566-2002 Class 3 fastener. The base steel shall be coated with zinc-aluminium alloy Zincalume (AZ150)(i.e. 55% Al. 43.4% Zinc. 1.6% Si) minimum of 150 g/m2 coating total on both sides, pre-painted with colorbond XRW (xterior roofing, walling) paint system of 35 micron Super Durable Polyester paint (SDP) with stable inorganic pigment with no lead contents confirming IS15965. The sheet shall be free from defects and have brand marking of the manufacturer giving product details on the back of the sheet at regular interval confirming genuinits of the material. In roof with 0.5 mm thick sheet. in 2nd floor
Galvanised or painted wind-tie made of M.S. flats, fitted and fixed complete including cost of necessary fittings. (a) Made with 40 mm. X 6 mm. flats
Aluminium sheet ridging fitted with self tapping screws, EPDM washers etc complete.(Minimum 225mm end lapping). (A) 300 mm lapping each way. (a) With 0.71 mm sheet
Galvanised iron sheet eaves gutter fitted and fixed with necessary 50 mm X 6 mm M.S flat bar clamps bent to design, bolts, nuts, washers etc. complete. Eaves gutter made of 0.63 mm. sheets.(300mm End lapping) (a) 225 mm. wide gutter
Wooden eaves board as per design, fitted and fixed complete: In ground floor (iii) Ornamental eaves board Badam /Gamar/ Champ/ Hallak) (a) 19mm thick. in 2nd floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (First Floor ). [Excluding cost of chipping over concrete surface] With 1:4 cement mortar. 15 mm thick plaster
2nd Floor With 1:4 cement mortar. 15 mm thick plaster
Ground Floor With 1:4 cement mortar. 10 mm thick plaster
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid / Bitumen / M-Seal etc) complete. A) UPVC Pipes: (ii) 110 mm. Dia.
(iii) 160 mm. Dia.
B) UPVC Fittings: c) Bend 87.5 degree. (ii) 110 mm. Dia.
(iii) 160 mm. Dia.
Plain TEE (iii) 160 mm. Dia.
a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc
A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With super gloss (hi-gloss). (iv) Two coats (with any shade except white)
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In 2nd Floor: (a) One Coat
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification...In 2nd Floor(Two Coats) b) Premium 100% Acrylic Emulsion
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge.
Repairs to cracks in terraced roof by cutting V-grooves 75 mm. to 100 mm. deep and 150 mm. to 200 mm. wide and filling the same with beaten lime concrete (2:2:7) with lime putty / paste and finishing complete (2 lime putty / paste : 2 surki : 7 brick khoa )
Add GST @ 18%
Add Labour Welfare Cess @ 1%
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.63 MB
WBF2911.pdf
Tender Documents • 0.80 MB
BOQ_2443506.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid