Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹344.4 CrAccepted-AOC AT MALANI COMPLEX 58 KOTECHA NAGAR KALAVAD ROAD RAJKOT 360001 GUJARAT INDIA | RAJKOT | GUJARAT | 360001 | ₹344.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹351.2 CrRejected-Finance DEE VEE HOUSE MAULSHREE VIHAR IN FRONT OF HOTEL BABYLON INTERNATIONAL VIP ROAD RAIPUR 492006 CHHATTISGARH | ₹351.2 Cr | L2 | Rejected-Finance Malani Construction Co. is L1 Bidder |
| 3 | L3₹353.7 CrRejected-Finance | ₹353.7 Cr | L3 | Rejected-Finance Malani Construction Co. is L1 Bidder |
| 4 | L4₹356.0 CrRejected-Finance NOT SPECIFIED | ₹356.0 Cr | L4 | Rejected-Finance Malani Construction Co. is L1 Bidder |
| 5 | Rejected-Technical | - | - | Rejected-Technical Disqualified as per Clause 4 of RFP document page 25 Disqualification |
Tender Value
₹330.7 Cr
EMD Value
₹5 L
Closing Date
15 Feb 2023, 3:00 pmClosed
The Regional Manager,WAPCOS Limited
WAPCOS LIMITED 1st Floor, JP Krishna Building, Pallimukku, Pettah Trivandrum - 695024
Development of Malabar Cancer Centre, Thalasseri (2nd Phase) in Kannur District
2023_WAPCO_546396_1
WAP/INFRA/KERALA/2022/MCC/418
Open Tender
Civil Works - Buildings
1080 days
Malabar Cancer Centre, Kannur District
As per Tender Documents
20 documents required · 20 mandatory
₹16,800
₹5 L
WAPCOS Limited,Trivandrum
26 Aug 2023
6 Jan 2023
17 Feb 2023
6 Jan 2023
15 Feb 2023
23 Jan 2023
16 Jan 2023
Amount
SUB STRUCTURE
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
od271211/2022_2023 : Extra for every additional lead of 1 km beyond initial lead of 50 m of the excavated/ stacked material. All kind of soil
od271212/2022_2023 : Extra for additional lead for every 1km above 1km up to 5km for disposing surplus excavated earth as per the direction of engineer in charge.
od271213/2022_2023 : Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used.<br>1000 mm dia piles
od271214/2022_2023 : Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used.<br>900 mm dia piles
od271215/2022_2023 : Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used.<br>800 mm dia piles
od271216/2022_2023 : Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used.<br>700 mm dia piles
od271217/2022_2023 : Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 of<br>specified diameter and length below pile cap, to carry a safe working load not less than specified,<br>excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and<br>temporary casing of appropriate length for setting out and removal of same and the length of the pile to<br>be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete,<br>including removal of excavated earth with all its lifts and leads (length of pile for payment shall be<br>measured up to bottom of pile cap).<br>Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used.<br>600 mm dia piles
od273409/2022_2023 : :"Boring, providing and installation bored cast-in-situ reinforced cement<br>concrete<br>piles<br>of garde M-30 ofspecified diameter and length below pile cap, to carry a safe working<br>load not less<br>than<br>specified,excluding the cost of steel reinforcement but including the cost of<br>boring with bentonite<br>solution<br>andtemporary casing of appropriate length for setting out and<br>removal of same and the length<br>of the pile<br>tobe embedded in the pile cap etc. by Crawler mounted,<br>telescopic boom hydraulic pilling Rig<br>all<br>complete,including removal of excavated earth with all its<br>lifts and leads (length of pile for payment<br>shall<br>bemeasured up to bottom of pile cap).Note: Truck<br>Mounted rotary/TMR/Tube well boring machine<br>shall not<br>be used. Minimum cement content of 350<br>kg/cum 500MM<br>"
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work upto plinth level
5.34.1 : Extra for providing richer mixes at all floor levels.Note:- Cement content considered in M-30 is @ 340 kg/cum.
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
6.12.1 : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in:Cement mortar 1:3 (1 cement : 3 coarse sand)
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
od271218/2022_2023 : Providing and laying FRP lining water proofing treatment in shar walls as per specification. The application shall be done only after cleaning of surface, there after applying powder with resin, compound, then laying of FRP lining (fibre glass lamination) by applying resin with blue pigment etc. as per manufactures specification. Application of first coat resin with chalk powder on the corner, uneven surface and undulation and laying the o Fibre glass lamination with resin and blue pigment, o Surfase mat lamination with resin. The second coat application shall be done with applying resin with Paraffin wax, chalk powder and blue pigment etc. complete. The rate includes preparation of surface, pressure grouting over slab & side wall, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry and testing of applied area complete.
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
od271219/2022_2023 : Carrying out initial vertical load tests as per relevant IS code including all arrangementsfor measuring deflections and submitting report as per specification including making pile head for testingat the required level, supporting / reaction arrangement ( including reaction piles/ soil/ rock anchors if any)for the kentledge load.1000mm dia piles ( 2.5 times the theoretical design vertical load capacity of 328 tonne.<br>
od271220/2022_2023 : Carrying out static routine vertical load tests as per relevant IS coded including all arrangements for measuring deflection and submitting reports as per specification and approved drawing including making of pile head for testing the required level, supporting / reaction arrangement ( including reaction piles/ soil/ rock anchors if any) for the kentledge load.1000mm dia piles ( 1.5 times the theoretical design vertical load capacity of 328 tonne .
od271221/2022_2023 : Carrying out static routine vertical load tests as per relevant IS coded including all arrangements for measuring deflection and submitting reports as per specification and approved drawing including making of pile head for testing the required level, supporting / reaction arrangement ( including reaction piles/ soil/ rock anchors if any) for the kentledge load.900mm dia piles ( 1.5 times the theoretical design vertical load capacity of 265 tonne .
od271222/2022_2023 : Carrying out static routine vertical load tests as per relevant IS coded including all arrangements for measuring deflection and submitting reports as per specification and approved drawing including making of pile head for testing the required level, supporting / reaction arrangement ( including reaction piles/ soil/ rock anchors if any) for the kentledge load.800mm dia piles ( 1.5 times the theoretical design vertical load capacity of 209 tonne .
od271223/2022_2023 : Carrying out static routine vertical load tests as per relevant IS coded including all arrangements for measuring deflection and submitting reports as per specification and approved drawing including making of pile head for testing the required level, supporting / reaction arrangement ( including reaction piles/ soil/ rock anchors if any) for the kentledge load.700mm dia piles ( 1.5 times the theoretical design vertical load capacity of 162 tonne .
od271224/2022_2023 : Carrying out static routine vertical load tests as per relevant IS coded including all arrangements for measuring deflection and submitting reports as per specification and approved drawing including making of pile head for testing the required level, supporting / reaction arrangement ( including reaction piles/ soil/ rock anchors if any) for the kentledge load.600mm dia piles ( 1.5 times the theoretical design vertical load capacity of 119 tonne .
od273401/2022_2023 : Carrying out static routine vertical load tests as per relevant IS coded including all<br>arrangements for measuring deflection and submitting reports as per specification and approved drawing<br>including making of pile head for testing the required level, supporting / reaction arrangement ( including<br>reaction piles/ soil/ rock anchors if any) for the kentledge load.600mm dia piles ( 1.5 times the theoretical<br>design vertical load capacity) 82 tonne
2.35.3.1 : Diluting and injecting chemical emulsion for POST -CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
2.34.1 : Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos / Lindane emulsifiable concentrate of 20%
od271225/2022_2023 : Providing Z steel sheet pile of size 400x185x7.5/8.5 driving down vertically in lines and levels interlocking with adjacent piles with suitable pile driving unit and all accessories including all labour hire charges etc. complete and as per the directions of departmental officers at site.
22.4.1 : Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)
SUPER STRUCTURE
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum.All work above plinth level upto floor V level
5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Cement content considered in M-30 is @ 340 kg/cum.
od286984/2022_2023 : Extra for providing richer mixes at all floor levels. Note : Cementcontent considered in M-45 is @ 360 kg/cum.
5.38 : Extra for R.C.C. /B.M.C/R.M.C. work above floor V level for each four floors or part thereof.
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
od274085/2022_2023 : Solid block masonry using pre cast Fly Ash solid blocks (Factory made with a minimum fly ash composition of 40%)) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.-50.6.1.2
od274086/2022_2023 : Solid block masonry using pre cast Fly ash solid blocks (Factory made with a minimum fly ash composition of 40%) of size 40x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure above floor two level up to floor V level thickness 20cm and above in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
od274087/2022_2023 : Solid block masonry using pre cast Fly ash solid blocks (Factory made with a minimum fly ash composition of 40%) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
od274088/2022_2023 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure from floor two level to floor five level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
6.5 : Extra for brick work/ AAC block masonry/Tile brick masonry in super structure above floor V level, for each four floors or part thereof by mechanical means.
Finishing Work -1
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
5.23 : Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 ( cement : 3 fine sand).
CIVIL FINISHING WORK
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
Civil Works Finishing
13.9.1 : Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Civil Finishing work
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
od274394/2022_2023 : Providing two coats of wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
13.44.1 : Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
25.6 : Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc., all complete for the required performance as specified, as per the architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in - Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass panels in the curtain glazing is included in cost of relevent item*). (ii) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face #2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35%, Light reflection internal 10 to 15%, light reflection external 10 to 20%, shading coefficient (0.25 - 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Civil Works Finishing
od286304/2022_2023 : <br>Finishing walls with Acrylic Smooth exterior paint having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
od286305/2022_2023 : Providing and laying 2.5mm thick FRP lining water proofing treatment in retaining wall as per specification. The application shall be done only after cleaning of surface, there after applying powder with resin, compound, then laying of FRP lining (fiber glass lamination) by applying resin with blue pigment etc. as per manufactures specification. Application of first coat resin with chalk powder on the corner, uneven surface and undulation and laying the o Fiber glass lamination with resin and blue pigment, o Surface mat lamination with resin. The second coat application shall be done with applying resin with Paraffin wax, chalk powder and blue pigment etc. complete. The rate includes preparation of surface, pressure grouting over slab & side wall, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry and testing of applied area complete.<br>
od286306/2022_2023 : Providing & grouting with cement slurry mix of approved ratio using pressure pump for water retaining concrete structures as per approved procedure including cost of nipples/ nozzles, cement, admixture, curing, pressure pumps, slurry agitator etc. all complete. Cost shall include fixing of nipples at minimum 500 mm center to center spacing, cutting of nipples after completing of grouting, making good of the nipple hole with appropriate non-shrink cement paste, water tightness test etc. all complete wherever required.<br>
od286307/2022_2023 : Providing and laying 2.5mm thick FRP lining water proofing treatment in sunken portion of WC's bathroom etc. as per specification. The application shall be done only after cleaning of surface, there after applying powder with resin, compound, then laying of FRP lining (fibre glass lamination) by applying resin with blue pigment etc. as per manufactures specification. Application of first coat resin with chalk powder on the corner, uneven surface and undulation and laying the o Fibre glass lamination with resin and blue pigment, o Surfase mat lamination with resin. The second coat application shall be done with applying resin with Paraffin wax, chalk powder and blue pigment etc. complete. The rate includes preparation of surface, pressure grouting over slab & side wall, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry and testing of applied area complete.<br>
od286308/2022_2023 : Providing and laying 2.5mm thick FRP lining water proofing treatment in terrace & sunshades as per specification. The application shall be done only after cleaning of surface, there after applying powder with resin, compound, then laying of FRP lining (fibre glass lamination) by applying resin with blue pigment etc. as per manufactures specification. Application of first coat resin with chalk powder on the corner, uneven surface and undulation and laying the o Fibre glass lamination with resin and blue pigment, o Surfase mat lamination with resin. The second coat application shall be done with applying resin with Paraffin wax, chalk powder and blue pigment etc. complete. The rate includes preparation of surface, pressure grouting over slab & side wall, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry and testing of applied area complete.<br>
od286309/2022_2023 : Providing and laying 2.5mm thick FRP lining water proofing treatment in water tank as per specification. The application shall be done only after cleaning of surface, there after applying powder with resin, compound, then laying of FRP lining (fibre glass lamination) by applying resin with blue pigment etc. as per manufactures specification. Application of first coat resin with chalk powder on the corner, uneven surface and undulation and laying the o Fibre glass lamination with resin and blue pigment, o Surfase mat lamination with resin. The second coat application shall be done with applying resin with Paraffin wax, chalk powder and blue pigment etc. complete. The rate includes preparation of surface, pressure grouting over slab & side wall, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry and testing of applied area complete.<br>
od286310/2022_2023 : Providing cinder concrete in sunken floors at all levels of proportion one part of cement and ten parts of cinder by volume by using Cinder from furnaces of steam boilers using coal fuel. The cinder should be cleaned, free from durt and wood ashes and shall pass through IS 3.35 sieve with 50% passing through IS 1.70 sieve and should not contain more than 10% of unburnt carbon and not more than 0.5% of acid soluble sulphates(SO).including soaking , curing etc. complete as per specification.<br>
12.63 : Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittnce tested as per ASTM) C 1549 and ASTM C 1371 respectively), VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strictly as per manufacture's specifications and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc., washing with water all complete. The contractor shall give guarantee for the performance of SRI and also the durability of coating, all complete as per direction of Engineer - in- charge.
Finishing work
od288624/2022_2023 : Painting with 2 coat of synthetic enamel paint having VOC (Volatile Organic Compound) content less than 150grams/ litre, of approved brand and manufacture, including applying primer and additional coats wherever required toachieve even shade and colour for grill works for windows and ventilators.
od288625/2022_2023 : Providing Polyurethane based Melamine spray polishing with two or more coats on new works including a coat of wood filler, melamine primer. Melamine sealer etc.<br>
od288626/2022_2023 : Providing painting with 2 coat s of approved clear water based wood preservative to the wooden frame work with deep penetrating formula having VOC (Volatile Organic Compound) content less than 150 grams/ litre , ensure effective treatment and lasting protection against insect attack, re-infestation and per the direction of engineer in charge
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
11.20.3 : Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement
od288627/2022_2023 : Providing and laying vitrified floor tiles in 1200x1200mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with epoxy grouting and matching pigments etc., complete. Size of Tile1200x 1200 mm<br>
od288628/2022_2023 : Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade in skirting laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting the joints with epoxy grouting and matching pigments etc.Size of Tile1200x 1200 mm
od288629/2022_2023 : Providing and laying vitrified floor tiles in 1200x600mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with epoxy grouting and matching pigments etc., complete.Size of Tile1200x 600 mm
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
od288630/2022_2023 : Providing and laying Matt finish anti skid vitrified floor tiles in 600x600mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colors and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with epoxy grouting and matching pigments etc., complete.Size of Tile 600x 600 mm
od288631/2022_2023 : Providing and laying Matt finish anti skid vitrified floor tiles in 600x600mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colors and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with epoxy grouting and matching pigments etc., complete.Size of Tile 600x 600 mm - skirting.<br>
od288632/2022_2023 : Providing and laying anti skid vitrified tiles of size 600x600 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with epoxy grouting and matching pigments etc., complete.
od288633/2022_2023 : Providing and laying anti skid vitrified strip floor tiles of size 1000mmx1000mm with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colors and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 sand),including grouting of joints (Payment for grouting of joints to be made separately)..-For ramp area
od288634/2022_2023 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete asper the architectural drawings with 18 mm thick stone slab over 20 mm (average)thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment ofmatching shade including rubbing , curing and polishing etc. all complete asspecified and as directed by the Engineer-in-Charge.<br>Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent.
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm
od288635/2022_2023 : Providing and laying Vitrified wall tiles (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade in skirting laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).<br>Size of Tile 600x600 mm
11.48.2 : Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm
11.48.4 : Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 1000x1000 mm
od288636/2022_2023 : Providing and laying Polished Granite stone wall tiling in required design andpatterns, in linear as well as curvilinear portions of the building all complete asper the architectural drawings with 18 mm thick stone slab over 20 mm (average)thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed withcement slurry and pointing with white cement slurry admixed with pigment ofmatching shade including rubbing , curing and polishing etc. all complete asspecified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent.
9.105.3 : Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete.66 mm overall thickness Partition with 8 mm thick double skin Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process with Compressive Strength 225 kg/sq cm, Bending Strength 100 kg/sq cm
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work
od288637/2022_2023 : "Providing Sal wood flooring to the stage top with 20mm thick superior quality sal wood planks having a minimum width of 20cm screwed with 50mm size brass screws in suitable spacings and to frames made of 75 x 50mm size sal wood joistes covering the entire area of the stage at 60 cm c/c on both ways.The cavities between the stage floor and the frame should be filled with cleaned dry river sand and top covered with 16mm thick ISI standard marine plywood as a base and over that 6mm thick cork wood sheet shall be laid over the entire stage area. The Sal wood planks of the stage is to screwed to the joists through the base sheet of plywood and cork sheets at suitable intervels of 60cm with 50 mm size brass screws.The planks should be jointed properly without any gap and the joints of the planks should be stopped only at the frame portions. Top of the stage should be finished and polished with with mansion polish including rubbing with sand paper and cleaning the surface etc. complete<br> "<br>
od288638/2022_2023 : Providing 2 mm thickness Wear layer (EN429) , PVC Vinyl flooring RQ Restorable Quality having Carbon backing and carbon particles in the design with total weight 3200 g/m2 (EN430), PUR (polyurethane reinforced), Abrasion group P: 4.0mm, residual indentation approx, 0.02 mm, castor wheel test qualified, dimensional stability 0.40% static electrical charge <2kv good resistance of scratch , slip ,chemical and fire , doesn’t favour in growth of fungi. Electric resistance is as per EN 1081 and ESD approved . Restorable prosperities . Available in rolls. 100% recyclable. Low VOC emission after 28 days of installation (lower than100μg/m³). The specified materials used shall be 1. DLW Vinyl Conductive /ESD sheet flooring,Copper tape, Earth,Subfloor,Top Seam. The sheet shall be certified by ECHA, FDA, EPA and should contain silver phosphate glass antimicrobial technology to preserve and prevent degradation and prevent degradation caused by microbial growth and manufactures has to produce a product warranty for 15years .This material is specified to be used inthe Hospitals and OTs.
od288639/2022_2023 : Providing & fixing 2.5mm thick antimicrobial rigid sheet wall panelling with wringle skin UPVC sheet in White and Pastel shades with satin finish. The sheet shall be heat mouldable to take the shape of wall corners etc. The approved sheet in required colour and shade shall be fixed properly on the walls without bubbles, air gaps or wringles, and shall be pasted with approved quality 2-part polyurethane product compact adhesive. Welding of joints shall be carried out with approved and matching colour welding rod and shall be made seamless appearance. The sheet shall be certified by ECHA, FDA, EPA and should contain silver phosphate glass antimicrobial technology to preserve and prevent degradation and prevent degradation caused by microbial growth and manufactures has to produce a product warranty for 15years .Rate inclusive of providing and laying ceiling coves, if any, etc.complete in all respect as directed by Engineer in charge .
od288640/2022_2023 : Providing & laying thick linen floor mat (synthetic carpet OBT) of approved make, shade and design over the plaster finished floor and fixing the same with bostic make adhesive of approved make as directed by the Engineer. standard grades is Synthetic Rubber (SBR), Reinforcing Agents, Resins, Curing Agents, Antioxidants and Pigments etc. complete.<br>
od288641/2022_2023 : Providing & laying thick art worked linen wall mat (synthetic wall carpet OBT) of approved make, shade and design over the plaster finished surface and fixing the same with bostic make adhesive of approved make, excluding cost cost of wood wool, frame works, chanels etc. complete as directed by the Engineer.<br>
od288642/2022_2023 : Providing Acoustical Wall Paneling of Strand MB Primer of size 600 X 1200 X 20mm thickness panels installed on Strut CC 50 at 600 mm centre. Panels to be backlined with backing material Synth PF 10x50mm of density 1000 gsm anf fire -class 1/A, Acoustics-NRC up to 0.90 and relative humidity of 95 etc.complete as per specfication. for Auditorium wall & mini symposium wall, board room, seminar hall
Civil works Finishing
od245189/2020_2021 : "Providing and fixing Clip-in Metal Ceiling System of 600x600 mm module which includes providing and fixing ‘C’ wall angle of size20x30x20mm made of 0.5mm thick pre painted aluminum along the perimeter of the room with help of nylon sleeves and wooden screws at 300mm centre to centre, suspending the main C carrier of size 10x38x10mm made of Aluminum 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000mm c/c Inverted triangle shaped Spring Tee having height of 24 mm and width of 34mm made of Aluminum 0.45 mm thick is then fixed to the main 'C' carrier and in direction perpendicular to it at 600mm centres with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120<br>gms/sqm (both side inclusive) Fixing with clip in tiles into spring 'T' with :0.70mm Aluminum Clip in type 600X600mm "
12.52.1 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending
12.52.2 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in perforated Tegular global white color tiles of size 595x595 mm and 0.5mm thick with 8 mm drop; made of GI sheet having glavanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyster powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
26.26.1 : Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles.
26.26.2 : Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.With fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG false ceiling tiles.
12.45.3 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board
od245236/2020_2021 : Providing and fixing in position Acoustical false ceiling at all heights with Fully Perforated Gypsum panel having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e. vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastener with 10mm bolt. This same channel is then to be fixed in horizontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glass wool of 50mm thickness is then to be fixed in the slots and finally Gypsum board panels are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre )roll and two coats of primer suitable for paneling as per manufacturer's specification as per direction of Engineer-in-Charge all complete. <br><br>
od160665/2021_2022 : Providing and fixing false ceiling 250 mm x 6 mm thick multi chamber hollow PVC panel .The support from ceiling is to be provided using 25 mm x 25 mm size aluminum square tube pipe at a distance of 2 ft (Framing work) with complete fitting etc complete as per specification.
13.52.2 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work
11.3.1 : Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
25.1 : Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).
25.2 : Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub-head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories 1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr” 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.” 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing method for a range upto 2000 ml” 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml”
od286229/2021_2022 : Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units with 41.1% of light transmission, 16.3 % outdoor relection and 18.1% indoor reflection with solar factor of 0.2365 and shading coefficient of 0.2719 and energy factors of 30.6% transmission ,32.2% relection , 36.2% indoor reflection, 35.5 % absorption(AE1) and1.70% Absorption (AE2) with thermal transmission of ug 1.541 W/m2.k etc.of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in- Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm
25.7 : Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Alumini um sheets (each0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
21.18 : Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately)
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.2.2 : Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
od250875/2021_2022 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with 41.1% of light transmission, 16.3 % outdoor relection and 18.1% indoor reflection with solar factor of 0.2365 and shading coefficient of 0.2917 and energy factors of 30.6% transmission ,32.2% relection , 36.2% indoor reflection, 35.5 % absorption(AE1) and1.70% Absorption (AE2) with thermal transmission of ug 1.541 W/m2.k etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):
od193734/2020_2021 : Providing and fixing Aluminium composite panel 4mm thick for aluminium doors with necessary screws, beedings etc complete<br>
9.147C.2 : Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately).<br> Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.(Area of door upto 2.50 sqm)
od245545/2020_2021 : Providing and fxing 54mm thick pre fitted acoustic doors with 35DB rating and 5D60 fire rated standard 90x40mm hard wood section frame with 30mm door stop and 90x20cm threshold with veneer flush of approved color and vison panels as per approved dimension etc. complete as per specification.
od245921/2020_2021 : Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic addit ives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).<br> Frame size 45 x 85 mm
od245922/2020_2021 : Providing and fixing 30mm thick factory made single extruded WPC {Wood Polymer Composite) solid decorative type panelled/flush door shutter of required size comprising of virgin polymer of K value 58-60 {Suspension Grade), calcium carbonate and natural fibers {wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawa l strength of 1800 N (Face) & 900 N {Edge), minimum compressive strength 50N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fix ing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk 5.5 screws, all as per direction of Engineer-In- Charge. {Note: stainless steel butt hinges and necessary 5.5 screws shall be paid separately) for toilet door.<br>
od310867/2020_2021 : Supplying and fixing Non-Hermetically Sealed Manual Single Leaf Swing Door of Antimicrobial HPL finish Nik229 swing door of 44 mm thick with 45±2 kg/m3 density PUF insulated. Anodized aluminum alloy door profile. Wall frame 80 mm x 60 mm, 2.5 mm thick Al 6063 anodized with 2mm GI reinforced. Including providing double glazed vision panel with 4 mm clear glass (300 mm x 300 mm x 44 mm or above size as directed by Architect), euro norm cylinder lock with outside key and inside emergency release, both side SS D-handle , SS ball bearing hinges , door closure push and hold for active leaf , providing concealed drp seal , rubber gasket for air tightness, concealed/open Stainless steel Tower bolts of 250 & 150mm, Stainless steel door stopper etc. complete in all respect as directed by Engineer in charge. No Organic material (No Decay and No Contamination) for all main doors.
od311255/2020_2021 : Supplying and fixing Non-Hermetically Sealed Manual Double Leaf Swing Door of Antimicrobial HPL finish Nik229 swing door of 44 mm thick with 45±2 kg/m3 density PUF insulated. Anodized aluminum alloy door profile. Wall frame 80 mm x 60 mm, 2.5 mm thick Al 6063 anodized with 2mm GI reinforced. Including providing double glazed vision panel with 4 mm clear glass (300 mm x 300 mm x 44 mm or above size as directed by Architect), euro norm cylinder lock with outside key and inside emergency release, both side SS D-handle , SS ball bearing hinges , door closure push and hold for active leaf , providing concealed drp seal, rubber gasket for air tightness, concealed/open Stainless steel Tower bolts of 250 & 150mm, Stainless steel door stopper etc. complete in all respect as directed by Engineer in charge. No Organic material (No Decay and No Contamination) for all main doors.
od311295/2020_2021 : " Supplying and fixing Non-Hermetically Sealed Manual Single Leaf Swing Door of SS 304 finish Nik229 swing door of 44 mm thick with 45±2 kg/m3 density PUF insulated. Anodized aluminum alloy door profile. Wall frame 80 mm x 60 mm, 2.5 mm thick Al 6063 anodized with 2mm GI reinforced. Including providing double glazed vision panel with 4 mm clear glass (300 mm x 300 mm x 44 mm or above size as directed by Architect), euro norm cylinder lock with outside key and inside emergency release, both side SS D-handle , SS ball bearing hinges , door closure push and hold for active leaf , providing concealed drp seal , rubber gasket for air tightness, concealed/open Stainless steel Tower bolts of 250 & 150mm, Stainless steel door stopper etc. complete in all respect as directed by Engineer in charge. No Organic material (No Decay and No Contamination) . Only for BMT & CSSD areas."
od311309/2020_2021 : Supplying and fixing Non-Hermetically Sealed Manual Double Leaf Swing Door of SS 304 finish Nik229 swing door of 44 mm thick with 45±2 kg/m3 density PUF insulated. Anodized aluminum alloy door profile. Wall frame 80 mm x 60 mm, 2.5 mm thick Al 6063 anodized with 2mm GI reinforced. Including providing double glazed vision panel with 4 mm clear glass (300 mm x 300 mm x 44 mm or above size as directed by Architect), euro norm cylinder lock with outside key and inside emergency release, both side SS D-handle , SS ball bearing hinges , door closure push and hold for active leaf , providing concealed drp seal , rubber gasket for air tightness, concealed/open Stainless steel Tower bolts of 250 & 150mm, Stainless steel door stopper etc. complete in all respect as directed by Engineer in charge. No Organic material (No Decay and No Contamination) . Only for BMT & CSSD areas.
od311317/2020_2021 : Providing flush doors using 40mm of 2.1m height with varying width using particle board core with soft perimeter frame and 0.5mm thick teak wood lipping & polishing on all edges with approved shade of high laminate bonded both sides with phenol formaldehyde resin and hot preddd based on BSEN 942 specifcation inluding providing hard wood door frame of size 10x5cm thick, providing 30cm x30cm vision panel of 4mm clear glass, anchored to walls, provided 5 nos of 5" heavy duty hinges, mortice lock, bolts, door stoppers etc. including fixing in position, making good any damage etc. complete to detailed drawing and specification.( hardware hinges and fitting etc. to be paid separately) for non important areas.
od311507/2020_2021 : "Supplying and fixing Hermetically sealed single leaf automatic sliding door , Antimicrobial HPL Seam Less finish, Nik229 with lever handle both side for manual opening, Magic switch (hand sensor) and foot switch for automatic opening Lever handle for manual opening. Door profile made of Aluminum Alloy Grade 6063 Temper T6.Natural Anodized 20 μm as per EN ISO 2360.Component Polyurethane Rigid CFC Free, Blowing Agent: Water. Dimensional stability at +100°C & -25°C (2%max) as per DIN53431. Density 45Kg/M3 with max deviation of 2kg/m3 as per DIN53420. Condensation resistance at 38°C and 88RH > Max variation 2% in Weight and volume. Lever Handle Solid AISI 304 Grade Stainless Steel, Rubber spring system . Roller Material PA6G 210 (Self-lubricating) PA Bearings 2X per roller. Rail Aluminum Alloy, Grade 6063, Temper T6. Photo cell fitted across the door opening inside the wall frame. Intelligent Microprocessor Based SDA 04 DCB controller. (16-30 Vdc, 50VA (max),. 94W DC motor, IP40 protection Class, 24 Vdc. (CE Marked) imported from Netherlands. Touchless radar switch. AISI 304 grade Stainless Steel Foot Switches with high quality inductive sensors. Double glazed IG unit with 5 mm tempered glass of size 300 mm x 300 mm x 60mm, flush finished.<br>1800 x 2100 for Ots"
od311566/2020_2021 : "Supplying and fixing Hermetically sealed single leaf automatic sliding door , Antimicrobial HPL Seam Less finish, Nik229 with lever handle both side for manual opening, Magic switch (hand sensor) and foot switch for automatic opening Lever handle for manual opening. Door profile made of Aluminium Alloy Grade 6063 Temper T6.Natural Anodised 20 μm as per EN ISO 2360.Component Polyurethane Rigid CFC Free, Blowing Agent: Water. Dimensional stability at +100°C & -25°C (2%max) as per DIN53431. Density 45Kg/M3 with max deviation of 2kg/m3 as per DIN53420. Condensation resistance at 38°C and 88RH > Max variation 2% in Weight and volume. Lever Handle Solid AISI 304 Grade Stainless Steel, Rubber spring system . Roller Material PA6G 210 (Self-lubricating) PA Bearings 2X per roller. Rail Aluminium Alloy, Grade 6063, Temper T6. Photo cell fitted across the door opening inside the wall frame. Intelligent Microprocessor Based SDA 04 DCB controller. (16-30 Vdc, 50VA (max),. 94W DC motor, IP40 protection Class, 24 Vdc. (CE Marked) imported from Netherlands. Touch less radar switch . AISI 304 grade Stainless Steel Foot Switches with high quality inductive sensors . Double glazed IG unit with 5 mm tempered glass of size 300 mm x 300 mm x 60mm, flush finished.<br>150x210 for BMT
od311621/2020_2021 : "Providing automatic Non-Hermetically Sealed Double Leaf Swing Door with vison panel with SS 304 finish Nik229 swing door of 44 mm thick with 45±2 kg/m3 density PUF insulated. Anodized aluminum alloy door profile. Wall frame 80 mm x 60 mm, 2.5 mm thick Al 6063 anodized with 2mm GI reinforced. With euro norm cylinder lock outside key and inside emergency release, with D handle both side, with ball bearing hinges, with flush view port 300 mm x 300 mm x 44 mm, with door closure push and hold for active leaf ,with concealed drp seal .
od311633/2020_2021 : " Supplying and fixing non Hermetically sealed single leaf manual sliding door of Antimicrobial HPL Seam Less finish, Nik229 with lever handle both side for manual opening, Door profile made of Aluminium Alloy Grade 6063 Temper T6.Natural Anodised 20 μm as per EN ISO 2360. Component Polyurethane Rigid CFC Free, Blowing Agent: Water. Dimensional stability at +100°C & -25°C (2%max) as per DIN53431. Density 45Kg/M3 with max deviation of 2kg/m3 as per DIN53420. Condensation resistance at 38°C and 88RH > Max variation 2% in Weight and volume. Lever Handle Solid AISI 304 Grade Stainless Steel, Rubber spring system. Roller Material PA6G 210 (Self-lubricating) PA Bearings 2X per roller. Rail Aluminium Alloy, Grade 6063, Temper T6. Photo cell fitted across the door opening inside the wall frame. Double glazed IG unit with 5 mm tempered glass of size 300 mm x 300 mm x 60mm, flush finished."
od311670/2020_2021 : " Supplying and fixing non Hermetically sealed single leaf manual sliding door of SS 304 grade finish, Nik229 with lever handle both side for manual opening, Door profile made of Aluminium Alloy Grade 6063 Temper T6.Natural Anodised 20 μm as per EN ISO 2360. Component Polyurethane Rigid CFC Free, Blowing Agent: Water. Dimensional stability at +100°C & -25°C (2%max) as per DIN53431. Density 45Kg/M3 with max deviation of 2kg/m3 as per DIN53420. Condensation resistance at 38°C and 88RH > Max variation 2% in Weight and volume. Lever Handle Solid AISI 304 Grade Stainless Steel, Rubber spring system . Roller Material PA6G 210 (Self-lubricating) PA Bearings 2X per roller. Rail Aluminium Alloy, Grade 6063, Temper T6. Photo cell fitted across the door opening inside the wall frame. Double glazed IG unit with 5 mm tempered glass of size 300 mm x 300 mm x 60mm, flush finished. for isolation areas."<br>
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
10.7 : Providing and fixing ball bearing for rolling shutters.
10.8.1 : Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area
10.8.2 : Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 16.80 sqm in area
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).
od346309/2020_2021 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Anjili Frame size 100x80 mm for flush door
od251172/2021_2022 : Providing and fixing double glazed hermetically sealed glazing for windows with both side 6 mm thick glass panes having 12 mm air gap with 41.1% of light transmission, 16.3 % outdoor relection and 18.1% indoor reflection with solar factor of 0.2365 and shading coefficient of 0.2719 and energy factors of 30.6% transmission ,32.2% relection , 36.2% indoor reflection, 35.5 % absorption(AE1) and1.70% Absorption (AE2) with thermal transmission of ug 1.541 W/m2.k etc. including providing EPDM gasket,perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.as per specification.
od246085/2020_2021 : Providing 3M prestige 70 series or equvalent film alowing 40 to 90% natural light and with 50% heat reduction and 95% infrared light reduction , placing with any air bubble medium duty grey matt sun film in position including scaffolding if required etc. complete as per the instruction of engineer in charge.<br>
od246086/2020_2021 : Providing and fixing in position night vision series film(3M NV-15 or equvalent) allowing 15 to 25% of natural light in day time , heat reduction up to 70% , scratch resistance etc. for all windows.<br>
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
9.88 : Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
od230087/2020_2021 : Providing and fixing chromium plated brass handles with necessary screws etc.<br>complete:<br>150 mm
od246214/2020_2021 : Providing and fixing stainless steel tower bolts ISI marked with necessary screws etc. complete : 300x10 mm
od246248/2020_2021 : Providing and fixing stainless steel tower bolts ISI marked with necessary screws etc. complete :150x10 mm <br>
od246249/2020_2021 : Providing and fixing stainless steel door stopper with necessary screws etc. complete. Twin rubber stopper <br>
od246250/2020_2021 : Providing and fixing stainless steel Dust proof socket, under floor tile complete: . For tower bolt<br>
od353205/2020_2021 : Providing and fixing Door frame and Shutter made of 46mm thick steel fire check door of 120 minutes fire rating confirming to BS: 476 Part 22 and IS: 3614 Part II for stability and integrity, fabricated with 2 nos. 22 gauge thick galvanized steel sheet with infill of fire rated Acrylic Sealant and non-combustible core bonded to both faces of sheet with lock seam joints at stile edges and internal reinforcement at top, bottom and stile edges for Fire Rating. The door frames are manufactured from 18 gauge thick galvanized steel sheet pressed from to single rebate profile of size 125mm x 75mm. The frames shall be fixed using canon/hilti anchor bolts of size 10mm dia x 100mm long. The door frames and door shutters are finished with powder coating paint. The cost includes providing and fixing of minimum two-hour fire rated stainless steel ball bearing hinges 125 mm x 75mm x 3mm. The cost includes providing opening for vision panel of required size in shutters (cost of glass excluded) and fixing vision panels of specified size with complete fire rated gasket channel & moulding beading and filling the gap between moulding /beading and glass with suitable sealant.<br>
od353206/2020_2021 : Providing and fixing panic bar / latch (Single point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.<br>
od353207/2020_2021 : Providing and fixing concealed fire rated 120 minutes RT door closer along with necessary SS screws, bolts, nuts, washers etc. as per approved samples complete as per the direction of the Engineer-in-charge.
od353208/2020_2021 : Supply of vision panel in fire rated doors of 200 mm x 500 mm size made out of minimum 5 mm thick clear fire rated glass (imported) for 120 minutes fire rating of fully transparent in fire/non-fire conditions having minimum 93% transparency, in accordance with IS : 3614 Part -II and BS : 476 Part 20& 22 , for 120 min. fire rating for stability and integrity and insulation criteria .<br>
10.3 : Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts,locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer .
9.147A.2 : Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)<br> Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm).
9.147A.3 : Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)<br> Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm).
9.147A.5 : Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)<br> Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm).
9.147B.1 : 543 SUB HEAD : 9 - WOOD & PVC WORK 9.147B Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately).<br> Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
od245955/2020_2021 : Designing ,fabricating , deliver and fixing at site with high grade aluminium (alloy 6063T5) sliding window/ doors (TOSTEM or equavalent) with minimum acoustic performance of 25DB with the system provided to be pressure equalised, ventilated and drained and will have a wind load bearing capacity of 1 to 1.8 kPa ,air permeabilty 8m3 / h -m2, water permeabilty 150 Pa, 41.1% of light transmission, 16.3 % outdoor relection and 18.1% indoor reflection with solar factor of 0.2365 and shading coefficient of 0.2719 and energy factors of 30.6% transmission ,32.2% relection , 36.2% indoor reflection, 35.5 % absorption(AE1) and1.70% Absorption (AE2) with thermal transmission of ug 1.541 W/m2.k etc. , all aluminium profile (72m/104m - 2 tarck/ 3 track casement with 1/2 sah on nylon rollers ) to be finished with approved shade of ionized coating and to be delivered with protective tape wrapping, all gaskets to be EPDM cut to required length and to have tight joints at corners, EPDM gaskets to be with 11mm glass groove ,aluminium frame and to approved 5mm /6mm/8mm thick Low -E glass (SAINT GOBAIN or equavalent) from inside and outside around the periphery of glass to ensure the opening air tight and water tight with entire system to have a 10 year warranty . Fenestration to be carried between windows/ doors and masonry work with approved grade/ shade of silicon at both inside and out side etc. complete as per specification.
od194056/2020_2021 : Providing and fixing SS lock of size suitable for glass door with SS screws etc. complete as per direction of Engineer-in-Charge.<br>
od194111/2020_2021 : Providing and fixing SS H handle of size 450mm with SS screws etc. complete as per direction of Engineer-in-Charge.<br>
21.4.1 : Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With stainless steel cover plate minimum 1.25 mm thickness
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
od194189/2020_2021 : Providing MS fabricated canopy using 100mmx50mmx1.4mm section of approximate 60x60cm grids,100mmx50mmx2mm SS tube, providing 11.52mm thick toughened and laminated glass( 5mm clear toughened glass +1.52 PVB +5mm clear tougneded glass) fixed VHB on both sides, tapes, silicon etc. including two priming coat of metal primer, insulation at site including welding joints, providing 4 nos steel rod with tensioner, supports from column, beam at 45 degrees with minimum slope for water drainage , ensure proper fixing to beam/column etc. complete as per specification.<br>
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
12.47.1 : Providing & fixing UV stabilised fibre glass reinforced plastic sheet rooting up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8 mm dia G.I plain/ bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovings incorporating minimum 0.3% ultra-violet stabiliser in resin system under approxirnately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866. The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.2 mm thick corrugate 2.5"or 4.2" or 6") or step-down (2' or 3" or 6") as specified.
21.17 : Providing and fixing anodised aluminium grill ( anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.(Only weight of grill to be measured for payment ).
od194326/2020_2021 : Providing 10cm wide strips bitumen based mineral fibre pad conforming to IS 1838, so as to totally seal any gaps between the two joints/expansion gap before finishing plastering work and flooring etc. complete to specification.<br>
od194332/2020_2021 : Providing expansion joints on the roof by synthetic rubber water bar embedded in the expansion gap and insulating the surface with a coat of bitumen after forming a small hump profile over the joint by using 1:3 braced RCC cement plaster, providing flat first layer of bitumen felt of crown piece seal over the lap joints fixing with a layer of bitumen felt extending over the hump crown and finishing along the cemented surface of the two slabs, so as to continuously take any finishing work etc. complete to specification. <br>
6.40 : Providing and laying Gypsum panel partitions 100 mm thick with water proof Gypsum panels of size 666x500x100 mm, made of calcite phosphor Gypsum fixed with tongue and groove, jointed with bonding plaster as per manufacturers specifications in superstructure above plinth level up to floor V level. Gypsum blocks will have a minimum compressive strength of 9.3 kg/cm2
od248733/2020_2021 : Providing and fixing PVC corner guard of 51x51 mm vinyl aluminium profile in the edges and corners of tile work including cost conveyance labour charges etc complete.(including aluminium angle profile and vinyl top cover)<br><br><br><br><br><br><br>
od248857/2020_2021 : Providing 304 grade stainless steel grab handrail with 32mm diameter and 600mm long and capable of shock absorbtion , wrenching resistance of 1.4cm thickness for different location, screwing and fixing in position including L-bow bends, durable brackets etc. whichever required as per the instruction of engineer in charge.<br>
od248858/2020_2021 : Providing motorized stage curtain with dual vision , main valance, main traveler, olio valance and traveler , cyclodrama border and traveler, sky drp / back drp for auditorium and mini symposium stages using approved material and color etc. including all pulley , ropes, string, guide rails, fringes and braids tassels etc. complete as per specification.<br>
od249457/2020_2021 : Providing 200mm wide stainless steel crash rails with capable of shock absorption , wrenching resistance of 1.4mm thickness , screwing and fixing in position including Lbow bends, durable brackets etc. for smooth and continuous handrails in corridor or whichever required as per the instruction of engineer in charge.<br><br>
od306192/2020_2021 : "Providing, making and fixing of Roller Blinds for windows as per architectural drawing and as per manufacturer's specifications & instructions with heavy duty pvc roller fixed in ms painted/ powder coated bracket and roller shall be cover with approved coloured, quality and make fabric including necessary hardware, pulling chain etc. complete as per detail drawing, as specified and as directed by Engineer In charge. for Directors & all HOD rooms windows, Private rooms, deluxe rooms, VIP rooms, executive rooms, Major external windows BMT, Intensive chemo windows (in between external & internal window)<br><br><br><br><br><br><br><br>"<br>
od306194/2020_2021 : "Providing, making and fixing of Venetian vertical blinds for windows as per architectural drawing and as per manufacturer's specifications & instructions with heavy duty pvc roller fixed in ms painted/ powder coated bracket and roller shall be cover with approved coloured, quality and make fabric including necessary hardware, pulling chain etc. complete as per detail drawing, as specified and as directed by Engineer In charge. for Directors & all HOD rooms windows, Private rooms, deluxe rooms, VIP rooms, executive rooms, Major external windows BMT, Intensive chemo windows (in between external & internal window)<br><br><br><br><br><br><br><br>"<br>
od306195/2020_2021 : Providing and fixing Cubicle curtains in the wards suitable for beds laid. The rate includes all cost of cloth, curtain track, supports, hardware items, stitching charges and all labour charges including conveyance, loading unloading etc. complete in all respect. The length of curtain cloth should have 1metre more length than the channel length. The height of curtain should have 7.5feet or standard approved ht. payment shall be made only as per site measurements of works actually done. (Curtained track length only shall be measured for payment) for All multi bed areas (Recovery, ICU, General wards Palliative wards, Procedure rooms, etc)<br>
od346393/2020_2021 : "Providing and fixing cyclorama screen in plastic perforated material of perforations size 1.2mm (standard perforations) 0.5mm (micro perforations) perforations density 4.5% &weight 0.35 kg/m2.. The screen to be fixed on tubular frame made out of 35mm dia MS pipe. The screen is to be fixed as per approved drawing. The cyclorama MS framework is to be provided with wheels/ castors for forward/ backward movement of size as per drawing title stage lighting & furnishing drawing etc all complete as per direction of Engineer In Charge<br>"<br>
od354256/2020_2021 : Providing push back chair with 17"x17"x18mm 16guage CR square pipe rame, 31/2", moulded PU form covered with Transo Febrics & bottom covered with same as above, Back 30"x17"x18"mm 16guageCR square pipe and 1/2"x1/8"MS flat frame, 11/2"x2", Moulded PU form covered, with Transo Febrics & and rear side of back rest also covered with cup type powder coated CR sheet. Stand consist with 1"x1"x16guage CR square pipeand 1" x1/4", MS Flat, Seat and back working in movable push back fittings. Arm rest made high quality PU etc. complete as per specification.<br>
od249935/2020_2021 : Providing indoor potted plants well developed from top to bottom in clay/ plastic/ khurja pot with spill water holding containers including all necessary allied backups etc. complete as per specification and instruction of engineering in charge.-Snake plant<br><br>
od249937/2020_2021 : Providing indoor potted plants well developed from top to bottom in clay/ plastic/ khurja pot with spill water holding containers including all necessery allied backups etc. complete as per specification and instruction of engineering in charge.-Split leaf philodendron<br><br>
od249938/2020_2021 : Providing indoor potted plants well developed from top to bottom in clay/ plastic/ khurja pot with spill water holding containers including all necessery allied backups etc. complete as per specification and instruction of engineering in charge.-Corn plant<br><br>
od249942/2020_2021 : Providing indoor potted plants well developed from top to bottom in clay/ plastic/ khurja pot with spill water holding containers including all necessery allied backups etc. complete as per specification and instruction of engineering in charge.-<br>Spider plant<br>
od249943/2020_2021 : Providing indoor potted plants well developed from top to bottom in clay/ plastic/ khurja pot with spill water holding containers including all necessary allied backups etc. complete as per specification and instruction of engineering in charge.-Jade plant<br><br>
od249945/2020_2021 : Providing indoor potted plants well developed from top to bottom in clay/ plastic/ khurja pot with spill water holding containers including all necessary allied backups etc. complete as per specification and instruction of engineering in charge.-Majesty palm<br><br>
COUNTERS/ STORAGE SHELVES /FILE RACKS
od80347/2021_2022 : Providing granite topped counter ( excluding cost of granite slab) with stoage shelf below using good quality 18mm BWP ply wood laminated on all exposed sides with approved lmm thick laminates and 0.8mm thick white laminates on the inside including providing pull out drawer, lower side panels, lower back panel, divider panels etc. Providing vertical supports at every 90cm or near, providing approved company made handles, bolts, locking arrangements & all necessary hardware fittings like drawer sliders, wire manager etc. placed in position correctly with provision to draw cables etc.as per detailed drawing & specification.<br>
od80466/2021_2022 : Providing granite topped counter ( excluding cost of granite slab) with stoage shelf below using good quality 18mm BWP ply wood laminated on all exposed sides with approved lmm thick laminates and 0.8mm thick white laminates on the inside including providing lower side panels, lower back panel, divider panels etc. Providing vertical suppports at every 90cm or near, providing approved company made handles, bolts, locking arrangements & all necessary hardware fittings like drawer sliders, wire manager etc. placed in position correctly with provision to draw cables etc.as per detailed drawing & specification.<br>
od80472/2021_2022 : Providing and placing in position granite slabs of approved shade with bull nose bevelled edges with 2 cm over hang on the open or closed shelf's including providing seemless joints and pasted with approved quality fevicoal or equavalent paste etc complete as perspecification.<br>
od80495/2021_2022 : Providing storage shelves by using 19mm good quality BWP ply wood including providing internal partitions & shutters , providing laminated in exposed side with approved 1mm thick laminates and 0.8mm thick white laminates on the inside fixed to the wall to correct line and level including providing approved company made handles, bolts, locking arrangements & all necessary hardware fittings like drawer sliders, wire manager etc. as per detailed drawing & specification.<br>
od80496/2021_2022 : Providing filing shelf of 60/50/40cm wide as per detailed drawing using 19mm / 12mm approved quality plywood finished with laminate of approved shade as per drawing, providing required number of shelves for placing files as per drawing, providing approved hardware, hinges, locks, etc., placed in position etc., complete to specification.<br>
Malabar cancer center at Kannur - Civil works for Stack parking system
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work upto plinth level
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
od80484/2021_2022 : Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 60 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge . (Cost of truss/frame work shall be paid separately).<br>0.91mm Aluminum color coated profile with center to center pitch of 175 mm, depth of 46mm, top crest width of 41mm, bottom valley width of 80mm, overall profile width of 1144mm , cover width 1050mm .<br><br>
od78801/2021_2022 : Providing and fixing of Pre- coated colour Aluminium roofing accessories in 0.71 mm thickness , alloy 31500(IS designation) [Aluminium Alloy(AA) 3004 (ISO designation)] For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyster top coat 15-18 microns, using self drilling/ tapping SS screws of size 6x60mm with 3mm thick EPDM seal and SS plain washer complete:<br>UPVC Square Gutter (600 mm over all girth)
12.51.1 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm)
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
10.26.1 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube
SUMP TANK
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum.All work upto plinth level
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work above plinth level upto floor V level
5.38 : Extra for R.C.C. /B.M.C/R.M.C. work above floor V level for each four floors or part thereof.
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
od78716/2021_2022 : Providing and laying FRP lining water proofing treatment in water tank as per specification. The application shall be done only after cleaning of surface, there after applying powder with resin, compound, then laying of FRP lining (fiber glass lamination) by applying resin with blue pigment etc.as per manufactures specification. Application of first coat resin with chalk powder on the corner, uneven surface and undulation and laying the o Fiber glass lamination with resin and blue pigment, o Surface mat lamination with resin. The second coat application shall be done with applying resin with Paraffin wax, chalk powder and blue pigment etc. complete. The rate includes preparation of surface, pressure grouting over slab & side wall, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry and testing of applied area complete
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
od76602/2021_2022 : Providing heavy duty FRP manhole cover and frame of size 90cmx60cm internal dimension with load bearing capacity of 2.5 tonne made of polyester resin , fiber glass and fillers of approved quality fixing in correct line and level as directed by Engineer-in-charge.
od76603/2021_2022 : Providing heavy duty FRP manhole cover and frame of size 60cmx60cm internal dimension with load bearing capcity of 2.5 tonne made of polyster resin , fibre glass and fillers of approved quality fixing in correct line and level as directed by Engineer-in-charge.<br>
PLANT ROOM
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work above plinth level upto floor V level
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
od313902/2020_2021 : Solid block masonry using pre cast Fly ash solid blocks (Factory made with a minimum fly ash composition of 40%) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.83.2 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
od79100/2021_2022 : Providing and fixing Aluminum composite panel 4mm thick for aluminum doors with<br>necessary screws, beedings etc complete
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
od79104/2021_2022 : Providing and fixing SS lock of size suitable for aluminium door with SS screws etc.<br>complete as per direction of Engineer-in-Charge
od79106/2021_2022 : Providing and fixing stainless steel door stopper with necessary screws etc. complete.<br>Twin rubber stopper
od79107/2021_2022 : Providing and fixing stainless steel tower bolts ISI marked with necessary screws etc. complete :150x10 mm
od79108/2021_2022 : Providing and fixing SS D handle of size 450mm with SS screws etc. complete as per direction of Engineer-in-Charge.
9.71.2 : Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete:100x60x2.50 mm
EXTERIOR WORKS
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
7.8.1 : Coursed rubble masonry with hard stone (first or second sort) in superstructure above plinth level and upto floor five level.Masonry work (first sort), in cement mortar 1:6 (1 cement : 6 coarse sand)
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work upto plinth level
5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Cement content considered in M-30 is @ 340 kg/cum.
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
od285605/2021_2022 : <br>Finishing walls with Acrylic Smooth exterior paint having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)<br>
11.20.3 : Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement
10.26.1 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube
od286109/2021_2022 : <br>Painting with synthetic enamel paint having VOC (Volatile Organic Compound) content less than 150 grams/ litre of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of<br>approved brand and manufacture .
16.91.2 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
od163206/2021_2022 : "Construction of granular sub-base by providing graded material, spreading in uniform layers with motor<br>grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with<br>vibratory roller to achieve the desired density, complete as per specification. for base formation of<br>interlock paver block."<br>
Landscape works
od188580/2020_2021 : Taking pit size 0.75M x0.75M.x0.75M., fill it with earth and organic manure mixture and supply and planting trees SARACA ASOCA
od188586/2020_2021 : Taking pit size 0.75M x0.75M.x0.75M., fill it with earth and organic manure mixture and supply and planting trees MIMUSPOS ELENGI
od188592/2020_2021 : Taking pit size 0.45M x0.45M.x0.45M., fill it with earth and organic manure mixture and supply and planting shrubs HIBISCUS
od188594/2020_2021 : Taking pit size 1M x1M.x1M., fill it with earth and organic manure mixture and supply and planting tree ALSTONIA SCHOLARIS
od188596/2020_2021 : Taking pit size 0.3M x0.3M.x0.3M., fill it with earth and organic manure mixture and supply and planting shrubs CROSSANDRA
od188600/2020_2021 : Taking pit size 0.75M x0.75M.x0.75M., fill it with earth and organic manure mixture and supply and planting shrubs MICHELIA CHAMPACA
od188608/2020_2021 : Providing and fixing buffalo grass existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and even, watering with sprinkle
od188609/2020_2021 : Supply and spreading good earth for landscaping including all cost of material and labour charge etc complete
od188611/2020_2021 : Supply and planting of shurbs like NERIUM OLEANDER
od188614/2020_2021 : Installation of vertical garden with garden with panel and pot system inclunding all cost of panels,pots,potting mixture , nanofertilizers, plants and organic pesticides treatment .
od188620/2020_2021 : Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
Formation of Bituminous Tar Road
3.6 : Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m
3.15 : Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material with in all lifts and lead upto 1000 metres by Mechanical Means <br>
4.2.A.1 : Construction of granular sub-base by providing graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. <br> Grading-III -For lower sub base - Mix in Place Method<br>
4.12 : Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
5.1.a : Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means.
5.2.a : Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.
5.3.2.a : Providing and laying bituminous macadam with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with bituminous binder (VG 30), transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction.<br> For Grading II - (19 mm nominal size)<br>
5.6.2.a : Providing and laying bituminous concrete with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder( NRMB) @ 5.4 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects Grading - II (13.2 mm Nominal Size)<br>
3.18 : Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2
8.13 : Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.
8.11.1 : Painting lines, dashes, arrows etc on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control Over 10 cm in width
Drainage works
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
50.6.7.2 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum.All work upto plinth level
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
od221298/2020_2021 : Providing 10cm thick precast RCC slab 1.2m long 0.60cm wide with 9 numbers of 2.5cm dia drain holes placed at qual distacne , neatly finished and placed in position on top of drainage leaving 2cm clear gap between each slab for drainage etc. complete as per specification.<br>
Walkway
16.91.2 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
od249418/2020_2021 : Construction of granular sub-base by providing graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per specification. for base formation of interlock paver block.
Civil works for ELV Room
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
7.2.1 : Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand)
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work upto plinth level
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work above plinth level upto floor V level
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
od306840/2020_2021 : Solid block masonry using pre cast Fly ash solid blocks ( Factory made with a minimum fly ash composition of 40%) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for superstructure for 10 cm thick wall in CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.83.2 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
od79079/2021_2022 : Providing and fixing Aluminum composite panel 4mm thick for aluminum doors with<br>necessary screws, beedings etc complete
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
od79082/2021_2022 : Providing and fixing SS lock of size suitable for aluminium door with SS screws etc.<br>complete as per direction of Engineer-in-Charge
od79083/2021_2022 : Providing and fixing stainless steel door stopper with necessary screws etc. complete.<br>Twin rubber stopper
od79086/2021_2022 : Providing and fixing stainless steel tower bolts ISI marked with necessary screws etc. complete :150x10 mm
od79088/2021_2022 : Providing and fixing SS D handle of size 450mm with SS screws etc. complete as per direction of Engineer-in-Charge.
9.71.2 : Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete:100x60x2.50 mm
FORMATION OF BITUMINOUS TAR ROAD
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)
STP CIVIL WORK
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work upto plinth level
5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Cement content considered in M-30 is @ 340 kg/cum.
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
od363675/2020_2021 : Providing and laying FRP lining water proofing treatment in STP as per specification. The application shall be done only after cleaning of surface, there after applying powder with resin, compound, then laying of FRP lining (fiber glass lamination) by applying resin with blue pigment etc. as per manufactures specification. Application of first coat resin with chalk powder on the corner, uneven surface and undulation and laying the o Fiber glass lamination with resin and blue pigment, o Surface mat lamination with resin. The second coat application shall be done with applying resin with Paraffin wax, chalk powder and blue pigment etc. complete. The rate includes preparation of surface, pressure grouting over slab & side wall, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry and testing of applied area complete.<br>
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
od76841/2021_2022 : Providing heavy duty FRP manhole cover and frame of size 90cmx60cm internal dimension with load bearing capacity of 2.5 tonne made of polyester resin , fiber glass and fillers of approved quality fixing in correct line and level as directed by Engineer-in-charge.
od76842/2021_2022 : Providing heavy duty FRP manhole cover and frame of size 60cmx60cm internal dimension with load bearing capacity of 2.5 tonne made of polyester resin , fiber glass and fillers of approved quality fixing in correct line and level as directed by Engineer-in-charge.
PLANT ROOM
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work upto plinth level
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum.All work above plinth level upto floor V level
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
od294798/2020_2021 : Solid block masonry using pre cast Fly ash solid blocks (Factory made with a minimum fly ash composition of 40%) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.83.2 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
od79052/2021_2022 : Providing and fixing Aluminum composite panel 4mm thick for aluminum doors with<br>necessary screws, beedings etc complete
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
od79054/2021_2022 : Providing and fixing SS lock of size suitable for aluminium door with SS screws etc.<br>complete as per direction of Engineer-in-Charge
od79055/2021_2022 : Providing and fixing stainless steel door stopper with necessary screws etc. complete.<br>Twin rubber stopper
od79056/2021_2022 : Providing and fixing stainless steel tower bolts ISI marked with necessary screws etc. complete :150x10 mm
od79057/2021_2022 : Providing and fixing SS D handle of size 450mm with SS screws etc. complete as per direction of Engineer-in-Charge.
9.71.2 : Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete:100x60x2.50 mm
Collection Pit of Size 2Mx2Mx1.75M
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work upto plinth level
5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Cement content considered in M-30 is @ 340 kg/cum.
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
od363736/2020_2021 : Providing and laying FRP lining water proofing treatment in water tank as per specification. The application shall be done only after cleaning of surface, there after applying powder with resin, compound, then laying of FRP lining (fibre glass lamination) by applying resin with blue pigment etc. as per manufactures specification. Application of first coat resin with chalk powder on the corner, uneven surface and undulation and laying the o Fibre glass lamination with resin and blue pigment, o Surfase mat lamination with resin. The second coat application shall be done with applying resin with Paraffin wax, chalk powder and blue pigment etc. complete. The rate includes preparation of surface, pressure grouting over slab & side wall, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry and testing of applied area complete.<br>
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
od76842/2021_2022 : Providing heavy duty FRP manhole cover and frame of size 60cmx60cm internal dimension with load bearing capacity of 2.5 tonne made of polyester resin , fiber glass and fillers of approved quality fixing in correct line and level as directed by Engineer-in-charge.
SUMP TANK - CIVIL WORK
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
od188020/2020_2021 : Extra for every additional lead of 100m beyond initial lead of 50m of the excavated / stacked material all kind of soil
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work upto plinth level
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.13 : 12 mm cement plaster 1:2 ( 1 cement : 2 stone dust)
od280981/2020_2021 : Providing and laying FRP lining water proofing treatment in sunken portion of WC's bathroom, terrace, water tank,retianing wall etc. as per specification. The application shall be done only after cleaning of surface, there after applying powder with resin, compound, then laying of FRP lining (fibre glass lamination) by applying resin with blue pigment etc. as per manufactures specification. Application of first coat resin with chalk powder on the corner, uneven surface and undulation and laying the o Fibre glass lamination with resin and blue pigment, o Surfase mat lamination with resin. The second coat application shall be done with applying resin with Paraffin wax, chalk powder and blue pigment etc. complete. The rate includes preparation of surface, pressure grouting over slab & side wall, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry and testing of applied area complete.<br><br>
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
od76516/2021_2022 : Providing heavy duty FRP manhole cover and frame of size 90cmx60cm internal dimension with load bearing capcity of 2.5 tonne made of polyster resin , fibre glass and fillers of approved quality fixing in correct line and level as directed by Engineer-in-charge.<br>
od76517/2021_2022 : Providing heavy duty FRP manhole cover and frame of size 75cmx75cm internal dimension with load bearing capcity of 2.5 tonne made of polyster resin , fibre glass and fillers of approved quality fixing in correct line and level as directed by Engineer-in-charge.<br>
od76502/2021_2022 : "Providing of good Quality Heavy Duty Wall Supported type ALUMINUM LADDER Made from 10 SWG Aluminum Alloy ""C"" Section size - 66 x 33 x 3.15 mm, Rung - 25.4 mm Fluted type fixing correct line and level as directed by Engineer-in-charge.<br><br>"<br>
Malabar Cancer Center - Estimate for Effluent treatment plant
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work upto plinth level
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
od363836/2020_2021 : Providing and laying FRP lining water proofing treatment in water tank as per specification. The application shall be done only after cleaning of surface, there after applying powder with resin, compound, then laying of FRP lining (fibre glass lamination) by applying resin with blue pigment etc. as per manufactures specification. Application of first coat resin with chalk powder on the corner, uneven surface and undulation and laying the o Fibre glass lamination with resin and blue pigment, o Surfase mat lamination with resin. The second coat application shall be done with applying resin with Paraffin wax, chalk powder and blue pigment etc. complete. The rate includes preparation of surface, pressure grouting over slab & side wall, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry and testing of applied area complete.<br>
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
od76832/2021_2022 : Providing heavy duty FRP manhole cover and frame of size 90cmx60cm internal dimension with load bearing capacity of 2.5 tonne made of polyester resin , fiber glass and fillers of approved quality fixing in correct line and level as directed by Engineer-in-charge.<br>
od76833/2021_2022 : Providing heavy duty FRP manhole cover and frame of size 60cmx60cm internal dimension with load bearing capacity of 2.5 tonne made of polyester resin , fiber glass and fillers of approved quality fixing in correct line and level as directed by Engineer-in-charge.<br>
CONNECTING STAIRS / BRIDGE ROOF
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
od352285/2020_2021 : Providing and Sinking cast- in situ reinforced cement wells of grade M-30 1200mm diameter and length of 6.80m in all soils except hard rock to lines and level and plumb and level until good hard laterite strata and scooping out from inside and below the stiening including use of dredgers or any other appliances, hire and labour for kentledge, jetting, dewatering, blasting, vibrating or any other method including removal of obstacles and dumping the soil into suitable location etc , excluding the cost of steel reinforcement but including the cost of sinking etc. complete to specification. <br>
od352286/2020_2021 : Providing and Sinking cast- in situ reinforced cement wells of grade M-30 1000mm diameter and length of 6.80m in all soils except hard rock to lines and level and plumb and level until good hard laterite strata and scooping out from inside and below the stiening including use of dredgers or any other appliances, hire and labour for kentledge, jetting, dewatering, blasting, vibrating or any other method including removal of obstacles and dumping the soil into suitable location etc , excluding the cost of steel reinforcement but including the cost of sinking etc. complete to specification. <br>
od352309/2020_2021 : Filling inside wells with M sand and 6mm jelly mix with a ratio of 1:1 in layer of not more than 15cm thick, well rammed, watered, consolidated and vibrated etc. complying with standard specifications.
4.1.6 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work upto plinth level
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
od352293/2020_2021 : Providing ISMC of various weight encasing in RCC pedestal footing with MS base plates anchoring including proper welding & soldering and bolting to correct line and level etc. complete including cost of all material ,applying 2 coats of zychromate priming coat and 2 coat of premium enamel paint etc complete as per specification and drawing.<br>
od352294/2020_2021 : Providing ISMC of various weight encasing in RCC pedestal footing with MS base plate and anchors including proper welding & soldering and bolting to correct line and level etc. complete including cost of all material ,applying 2 coats of zychromate priming coat and 2 coat of premium enamel paint etc complete as per specification and drawing.<br>
od352295/2020_2021 : Providing ISMB beams for various weight fixed to ISMB post as a frame work as a load bearing structure so as to from a level surface ensure proper welding & soldering ,line level etc. complete including cost of all material ,applying 2 coats of zychromate priming coat and 2 coat of premium enamel paint etc complete as per specification and drawing.<br>
od352296/2020_2021 : Providing ISA 50X50X6 mm angles for tread connection welding to ISMB 450 beams & soldering ,line level etc. complete including cost of all material ,applying 2 coats of zychromate priming coat and 2 coat of premium enamel paint etc complete as per specification and drawing.<br>
od352297/2020_2021 : Providing ISA 50X50X6 mm column bracing welding to ISMB 450 beams & posts & soldering ,line level etc. complete including cost of all material ,applying 2 coats of zychromate priming coat and 2 coat of premium enamel paint etc complete as per specification and drawing.<br>
od352304/2020_2021 : Providing 10mm thick plates welding to ISA for tread connection & soldering ,line level etc. complete including cost of all material ,applying 2 coats of zychromate priming coat and 2 coat of premium enamel paint etc complete as per specification and drawing.<br>
od352305/2020_2021 : Providing 5mm thick plates welding to ISA for side covering of tread & soldering ,line level etc. complete including cost of all material ,applying 2 coats of zychromate priming coat and 2 coat of premium enamel paint etc complete as per specification and drawing.<br>
od352306/2020_2021 : Providing 8mm thick plates of size welding to ISMB Wherever required and soldering ,line level etc. complete including cost of all material ,applying 2 coats of zychromate priming coat and 2 coat of premium enamel paint etc complete as per specification and drawing.<br>
od352307/2020_2021 : Providing 12mm thick plates of 5000x5000mm size anchord to the top of RCC pedestal and soldering ,line level etc. complete including cost of all material ,applying 2 coats of zychromate priming coat and 2 coat of premium enamel paint etc complete as per specification and drawing.<br>
od352308/2020_2021 : Providing 8mm thick plates of 4000x4000mm size anchord to the top of RCC pedestal and soldering ,line level etc. complete including cost of all material ,applying 2 coats of zychromate priming coat and 2 coat of premium enamel paint etc complete as per specification and drawing.<br>
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
od247129/2020_2021 : Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately).
od247132/2020_2021 : Providing and laying stepping tiles in 100x30cm tread and 100x15cm riser sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with epoxy grouting and matching pigments etc., complete. as per specification.
od247165/2020_2021 : Providing 12mm thick approved quality ply wood for fixing steping tiles over the frame work for stepping fixing with screws and bolts to correct line and level etc. as per specifaction.
od247176/2020_2021 : Providing and laying rough textured floor tiles in 1200x1200mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with epoxy grouting and matching pigments etc., complete. Size of Tile1200x 1200 mm
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
21.1.1.1 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)
od77847/2021_2022 : Providing aluminium composite panel false ceiling in bridge ceiling areas following the existing prifile of ceiling using approved quality 3mm thick sheet with framing built with the aluminium extrusion profile .ACP panelling elements mounted with two part framing profile and corner pice as per manufactures specification including providing necessary cutting for fixing light fixtures, fire sprinkler head, smoke detector and air conditioning vents etc complete to specifications.<br>
RAIN / RAW WATER TANK(CAP: 1,93,000 LTS)/TREATED WATER TANK(CAP: 1,53,500 LTS)/FIRE WATER TANK (CAP: 2,57,000 LTS)
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
od249440/2020_2021 : "Extra for every additional lead of 100m beyond initial lead of 50m of the excavated / stacked material all kind of soil.
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work upto plinth level
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
50.6.3.1 : Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth for 10 cm thick wall in CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.13 : 12 mm cement plaster 1:2 ( 1 cement : 2 stone dust)
od283689/2020_2021 : "Providing and laying FRP lining water proofing treatment in sunken portion of WC's bathroom, terrace, water tank, retaining wall etc. as per specification. The application shall be done only after cleaning of surface, there after applying powder with resin, compound, then laying of FRP lining (fiber glass lamination) by applying resin with blue pigment etc. as per manufactures specification. Application of first coat resin with chalk powder on the corner, uneven surface and undulation and laying the o Fiber glass lamination with resin and blue pigment, o Surface mat lamination with resin. The second coat application shall be done with applying resin with Paraffin wax, chalk powder and blue pigment etc. complete. The rate includes preparation of surface, pressure grouting over slab & side wall, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry and testing of applied area complete.<br><br><br><br><br><br>"<br>
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
od76543/2021_2022 : Providing heavy duty FRP manhole cover and frame of size 90cmx60cm internal dimension with load bearing capcity of 2.5 tonne made of polyster resin , fibre glass and fillers of approved quality fixing in correct line and level as directed by Engineer-in-charge.<br>
od76544/2021_2022 : Providing heavy duty FRP manhole cover and frame of size 60cmx60cm internal dimension with load bearing capcity of 2.5 tonne made of polyster resin , fibre glass and fillers of approved quality fixing in correct line and level as directed by Engineer-in-charge.<br>
od250900/2020_2021 : Providing heavy duty PVC cohessive and centrifugal filter with element SS 304 screen and mesh size 250 micron with 90mm inlet and 63mm outlet connected to 90mm drain including insulation etc. complete as per specification.<br>
od73378/2021_2022 : "Providing of good Quality Heavy Duty Wall Supported type ALUMINUM LADDER Made from 10 SWG Aluminum Alloy ""C"" Section size - 66 x 33 x 3.15 mm, Rung - 25.4 mm Fluted type fixing correct line and level as directed by Engineer-in-charge.<br><br>"<br>
Rain water - Soak Pit
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work upto plinth level
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Demolition works
15.2.2 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
15.5 : Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge.
15.6 : Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B work.
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
15.9.2 : Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar
15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below
15.12.2 : Of area beyond 3 sq. metres
15.18 : Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates,boltd, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
15.23.1 : Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
15.28.1 : Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet
15.57 : Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
Front Block- Basement floor
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
od286129/2021_2022 : Painting with synthetic enamel paint having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
ADDITIONAL WORK FOR EXISTING DIESEL TANK ROOM
od71926/2021_2022 : Providing and making laying fire brick walls (Factory made) of size of fire retardant bricks 9''x4''x3'' or nearest available size laid in mortar of high alumina cement and fine aggregate of crushed fire brick 1:2 including cost of scaffolding for superstructures.<br>
4.7.1 : Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 ( 1 cement : 3 coarse sand), cost of required centering, shuttering complete:1:1.5:3 ( 1 cement : 1.5 coarse sand (Zone III): 3 graded stone aggregate 20 mm nominal size)
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
od286134/2021_2022 : Providing two coats of wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
od286158/2021_2022 : <br>Finishing walls with Acrylic Smooth exterior paint having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)<br>
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.2.2 : Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
9.88 : Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
od71980/2021_2022 : Providing and fixing stainless steel tower bolts ISI marked with necessary screws etc. complete : 300x10 mm
od71982/2021_2022 : Providing and fixing stainless steel tower bolts ISI marked with necessary screws etc. complete :150x10 mm <br>
Additional Safety Works
od352085/2020_2021 : Perimeter safety nets,used for some time as a type of safety device for workers in possible fall situations. The geometry of this type of net is controlled by the applicable standards The minimum horizontal projection from the side of the structure is either 8 ft (2.4 m) or 10 ft (3.1 m) , and the net must be positioned within 25 ft (7.6 m) or 30 ft (9.1 m) of the working surface above. The net must also have passed a prototype load test and, according to some standards, an on-site load test as well . 6 Inch GI Pipes shall be used for the support with a mesh size of 100mm <br>
od352086/2020_2021 : Provision of Agro net for dust control and spillage of loose grout during external plastering <br>
FIRE PUMPS, VALVES & ACCESSORIES
od79090/2020_2021 : Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic<br>operation and consisting of following, complete in all respects, as required :<br>(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless<br>steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC,<br>synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55<br>protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.<br>(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.<br>(d) Suitable cement concrete foundation duly plastered with anti vibration pads.2280lpm @100 mtr head
od314429/2020_2021 : Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)<br>a)Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.<br>b)Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325.<br>c)M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.<br>d)Suitable cement concrete foundation duly plastered and with anti vibration pads. 180lpm@100mtr head
od342892/2021_2022 : Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180lpm @65mtr head
od314430/2020_2021 : Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic<br>operation and consisting of following, complete in all respects, as required :<br>(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless<br>steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC,<br>synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55<br>protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.<br>(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.<br>(d) Suitable cement concrete foundation duly plastered with anti vibration pads.2280lpm @65 mtr head
od315958/2020_2021 : Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft,<br>mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 2280lpm @65mtr head
od314431/2020_2021 : Supply of below sized XLPE insulated PVC sheathed Aluminum conductor armored cabling to the incoming and outgoing of fire pump panel including necessary termination, glanding, necessary connections etc 3Cx 150 sq mm on wall, floor
od79093/2020_2021 : Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft,<br>mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 2280lpm @100mtr head
od79094/2020_2021 : Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)<br>a)Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.<br>b)Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325.<br>c)M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.<br>d)Suitable cement concrete foundation duly plastered and with anti vibration pads.180lpm @100mtr head
od323246/2021_2022 : Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.<br>250mm dia
od319262/2021_2022 : Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :<br>200mm dia
od79112/2020_2021 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required<br>250mm dia :
od84122/2020_2021 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with<br>bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets<br>conforming to IS 13095 of following sizes as required :<br>200mm dia
od84592/2020_2021 : Supply of below sized XLPE insulated PVC sheathed Aluminum conductor armored cabling to the incoming and outgoing of fire pump panel including necessary termination, glanding, necessary connections etc 3Cx 25 sq mm <br>
od84593/2020_2021 : Supply of below sized XLPE insulated PVC sheathed Aluminum conductor armored cabling to the incoming and outgoing of fire pump panel including necessary termination, glanding, necessary connections etc 3Cx 240sq mm on wall, floor
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
7.7.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
9.1.9 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 25 sq. mm (25mm)
9.1.18 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 240 sq. mm (62mm)
od323146/2021_2022 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :<br>80mm dia
od323147/2021_2022 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :<br>100 mm dia
od323148/2021_2022 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :<br>150 mm dia
od323198/2021_2022 : Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 80mm dia
od323199/2021_2022 : Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 100mm dia
od323200/2021_2022 : Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required<br>150 mm dia
od323201/2021_2022 : Providing, installation, testing and commissioning of non-return valve of following sizesconfirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required<br>200mm dia<br>
od323202/2021_2022 : Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :<br>250mm dia
od79120/2020_2021 : Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height<br>with air release valve on top and flanged connection to riser, drain arrangement with 25 mm<br>dia gun metal wheel valve with required accessories, pressure gauge and paintingwith<br>synthetic enamel paint of approved shade as required.<br>
od79121/2020_2021 : Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
od79122/2020_2021 : Supply, Installation,Testing and Commissioning of Pressure gauge with 0 to 200PSI,25 mm dia.
od79123/2020_2021 : Supply,Installation,Testing & Commissioning of Bronze body lever operated stainless steel ball valve (PN 20) of approved make with necessary MTA fittings in position as per drawings.-25 mm dia
od79124/2020_2021 : Supplying, fixing, testing and commissioning of following NON - RETURN VALVE of C I body vulcanized NBR seal flanged end & PN16 pressure rating as specified -25 mm dia
od85893/2020_2021 : Supply,Installation, testing & commissioning of installation control valve of cast iron body,brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MSpipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required.<br>200 mm dia
HYDRANT SYSTEM
od61671/2020_2021 : Supplying and fixing single headed internal hydrant valve with instantaneous<br>Gunmetal coupling of 63 mm dia with cast iron wheel ISI marked conforming<br>to IS 5290 (Type -A) with blank Gunmetal cap and chain as required :Single headed Gunmetal
od61672/2020_2021 : Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia<br>instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked,<br>conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required:single headed Gunmetal<br>
od61673/2020_2021 : Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal<br>diameter size nozzle conforming to IS 903 suitable for instantaneous connection to<br>interconnect hose pipe coupling as required :Gun metal
od61674/2020_2021 : Supply and Fixing of weather proof Hose cabinet suitable size "having made of 16 gauge MS Sheet with common keylock arrangements, suitable to accommodate two lengths of 15mtr hoses,and one no branch pipe with nozzle. The cabinet shall be painted to scarlet red colour out side and off-white inside.
od61675/2020_2021 : Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female<br>couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun Metal
od61676/2020_2021 : upplying and fixing first-aid Hose Reel with MS construction spray painted in post office<br>red, conforming to IS 884 complete with the following as required.<br>20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS:<br>12585<br>20 mm nominal internal dia gun metal globe valve & nozzle.<br>Drum and brackets for fixing the equipmets on wall.<br>Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket 30 m
od61677/2020_2021 : Supplying and fixing of fire brigade connection of cast iron body with gun metal male<br>instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe<br>connection conforming to IS 904 as required :4 way - 150 mm dia M.S. Pipe
od71167/2020_2021 : Supplying and fixing of fire brigade connection of cast iron body with gun metal male<br>instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe<br>connection conforming to IS 904 as required :3 way - 150 mm dia M.S. Pipe
od61678/2020_2021 : Supply,Installation,Testing and Commissioning of Air Release Valve GM 20mm dia type of approved make.
od61679/2020_2021 : Supply,Installation,Testing and Commissioning of Hydrant valve Chamber: Brick masonry chambers in cement mortar 1:5 (1 cement: 5 Coarse sand) on cement concrete foundations 150mm thick 1:4:8 mix (1 cement: 4 fine sand: 8 graded stone aggregate 40mm nominal size) 15mm thick cement plaster inside and outside finished with a floating coat of neat cement inside with cast iron surface box approved by local fire brigade including excavation, back filling complete. Valve chambers shall be of following sizes:<br>For depths up to 1mtr. 450mm X 450mm<br>For depths up to 1mtr. & beyond 1000mm X 1000mm
HYDRANT PIPE
od62986/2020_2021 : ABOVE GROUND :Providing, laying, testing & commissioning of 'C' class heavy duty GI Pipes conforming to IS 3589/IS 1239 including Grooved fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 200 mm dia
od76835/2020_2021 : ABOVE GROUND :Providing, laying, testing & commissioning of 'C' class heavy duty GI Pipes conforming to IS 3589/IS 1239 including Grooved fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 250 mm dia
od62987/2020_2021 : ABOVE GROUND :Providing, laying, testing & commissioning of 'C' class heavy duty GI Pipes conforming to IS 3589/IS 1239 including Grooved fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 150 mm dia
od62988/2020_2021 : ABOVE GROUND :Providing, laying, testing & commissioning of 'C' class heavy duty GI Pipes conforming to IS 3589/IS 1239 including Grooved fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia
od62989/2020_2021 : ABOVE GROUND :Providing, laying, testing & commissioning of 'C' class heavy duty GI Pipes conforming to IS 3589/IS 1239 including Grooved fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm dia
od76830/2020_2021 : Under ground piping : Supply,installation Testing and Commissioning of GI C class pipe of following sizes conforming to IS1239 with fabricated welded joints with neccessary fittings/ specials. The rate is inclusive of excavation & wrapping with approved wrapping tape of 4mm thickness.200 mm dia
od62990/2020_2021 : Under ground piping : Supply,installation Testing and Commissioning of GI C class pipe of following sizes conforming to IS1239 with fabricated welded joints with neccessary fittings/ specials. The rate is inclusive of excavation & wrapping with approved wrapping tape of 4mm thickness.150 mm dia
od62991/2020_2021 : Under ground piping : Supply,installation Testing and Commissioning of GI C class pipe of following sizes conforming to IS1239 with fabricated welded joints with neccessary fittings/ specials. The rate is inclusive of excavation & wrapping with approved wrapping tape of 4mm thickness.80 mm dia
FIRE SPRINKLER SYSTEM
od63011/2020_2021 : ABOVE GROUND :Providing, laying, testing & commissioning of 'C' class heavy duty GI Pipes conforming to IS 3589/IS 1239 including Grooved fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :<br> 150 mm dia
od63012/2020_2021 : ABOVE GROUND :Providing, laying, testing & commissioning of 'C' class heavy duty GI Pipes conforming to IS 3589/IS 1239 including Grooved fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia
od63013/2020_2021 : ABOVE GROUND :Providing, laying, testing & commissioning of 'C' class heavy duty GI Pipes conforming to IS 3589/IS 1239 including Grooved fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :<br> 80 mm dia
od63014/2020_2021 : ABOVE GROUND :Providing, laying, testing & commissioning of 'C' class heavy duty GI Pipes conforming to IS 3589/IS 1239 including Grooved fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 65 mm dia
od63015/2020_2021 : ABOVE GROUND :Providing, laying, testing & commissioning of 'C' class heavy duty GI Pipes conforming to IS 3589/IS 1239 including Grooved fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 50 mm dia
od63016/2020_2021 : ABOVE GROUND :Providing, laying, testing & commissioning of 'C' class heavy duty GI Pipes conforming to IS 3589/IS 1239 including threaded fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 40 mm dia
od63017/2020_2021 : ABOVE GROUND :Providing, laying, testing & commissioning of 'C' class heavy duty GI Pipes conforming to IS 3589/IS 1239 including threaded fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 32 mm dia
od63018/2020_2021 : ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. 25 mm dia
od63086/2020_2021 : Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of<br>rating 68 degree centigrade with required accessories :<br>Pendent Sprinkler
od63088/2020_2021 : Sprinkler Bulbs : Supply,Installation,Testing and Commissioning of 15 mm gun metal sprinkler heads Quick response standard coverage with quarts bulb and set to operate at a specified temperature as per the specifications.<br>Temperature of operation 79 degree Celsius. K 80 for other areas. Pendant type sprinkler
od63090/2020_2021 : Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of<br>rating 68 degree centigrade with required accessories :Horizontal side wall sprinkler<br>
od248986/2020_2021 : Sprinkler Bulbs : Supply,Installation,Testing and Commissioning of 15 mm gun metal sprinkler heads Quick response standard coverage with quarts bulb and set to operate at a specified temperature as per the specifications.The sprinkler can cover 16 feet wide by 24 feet long area.<br>Temperature of operation 68 degree Celsius. K 80 for other areas. extended coverage single side wall sprinkler
od63092/2020_2021 : Sprinkler Bulbs : Supply,Installation,Testing and Commissioning of 15 mm gun metal sprinkler heads Quick response standard coverage with quarts bulb and set to operate at a specified temperature as per the specifications.<br>Temperature of operation 68 degree Celsius. K 80 for other areas.Upright sprinkler type
od343416/2021_2022 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. 50 mm dia
od63098/2020_2021 : Supply,installing, testing and commissioning of Flow switch on sprinkler distribution header on each floor and shall be connected to Fire alarm panel through cable. 150 mm dia
od63099/2020_2021 : Supply,installing, testing and commissioning of Flow switch on sprinkler distribution header on each floor and shall be connected to Fire alarm panel through cable. 100 mm dia
od63100/2020_2021 : Supply,installing, testing and commissioning of Flow switch on sprinkler distribution header on each floor and shall be connected to Fire alarm panel through cable. 80 mm dia
od63109/2020_2021 : Supply, Installation,Testing and Commissioning of Sprinkler Flexible type of approved make. 1000 mm
od63111/2020_2021 : Supply, Installation,Testing and Commissioning of Sprinkler Flexible type of approved make. 1200 mm
od85902/2020_2021 : Supply, Installation, orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.Orifice Plate: Orifice OD: 127 mm<br>Flange dia required: 150 mm<br>Actual Orifice dia: Varies from 22 mm to 25 mm.
od248480/2020_2021 : Providing and fixing sight glass assembly of brass body and brass ball with chrome plated, steel handle, PN16 or above, UL Listed & FM Approved. Test and drain valve shall be with compact 3 position ball valves with drain orifice having K-factor 5.6 and a sight glass. 3 positions consist of OFF, TEST and<br>DRAIN. Test and drain valves shall be provided for test as well as express drain functions in wet sprinkler systems. The Test and Drain Valve shall be in Brass ASTM B584 material of construction. These have integral tamper resistant sight glass.
FIRE ALARMS (ADDRESSABLE) SYSTEM
od318639/2021_2022 : Supplying, installation, testing and commissioning of micro processor based<br>intelligent addressable main fire alarm panel, central processing unit with the<br>following loop modules and capable of supporting not less than 240 devices<br>(including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel<br>shall have facility to connect printer to printout log and facility to have seamless<br>integration with analog/digital voice evacuation system ( which is part of the schedule<br>of work under SH: PA System) and shall be complete with all accessories . The<br>panel shall be compatible for IBMS system with open protocol Bacnet/ Modbus over IP complete as per specifications.<br>Ten Loop Panel.
od318713/2021_2022 : Supplying, installation, testing & commissioning of central graphical fire alarm<br>management system to centrally monitor and operate the fire alarm system complete as required.
od318734/2021_2022 : Supplying, installation, testing & commissioning of repeater panel wih 320 character/Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
od318784/2021_2022 : Supplying, installation, testing & commissioning of intelligent interface unit BACnet/Modbus protocol i.e. supplying communication links between building managementsystem and fire alarm control panel complete as required.
od318772/2021_2022 : Supplying, installation, testing & commissioning of intelligent addressable thermal<br>detector with rate of rise cum fixed tempreature thermistor complete with base as<br>required.
od318756/2021_2022 : Supplying, installation, testing & commissioning of intelligent analog addressable<br>photothermal detector complete with mounting base complete as required.
od71948/2020_2021 : Supply, installation, testing and commissioning of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and 115cd flashintg at 1 Hz for visual indication. UL Listed
od319004/2021_2022 : Supplying, installation, testing & commissioning of addressable strobe complete<br>as required.
od318759/2021_2022 : Supplying, installation, testing & commisssioning of intelligent addressable<br>programmable sounder complete as required.
od342041/2021_2022 : Supplying, installation, testing & commissioning of addressable manual call point complete as required.<br>Details of cost for one each
od318780/2021_2022 : Supplying, installation, testing & commissioning of fire fighter telephone handset<br>complete as required.
od318979/2021_2022 : Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
od318562/2021_2022 : Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required
od71953/2020_2021 : Supply,Installation,Testing and Commissioning of Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Module shall be supplied with mounting plate allowing the remaining devices to continue operation.
od318763/2021_2022 : Supplying, installation, testing & commissioning of fault isolator complete with base as required.
od71954/2020_2021 : Supply, Installation,Testing and Commissioning of addressable control module for hooters at different locations complete with all fixing accessories.
od318777/2021_2022 : Supplying, installation, testing & commissioning of addressable fire control module complete as required.<br>
od71955/2020_2021 : Supply, Installation,Testing and Commissioning of Addressable Relay Module for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs. The relay module shall provide contact rated at 24v DC, 2A.Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate at different locations complete at different locations complete with all fixing accessories. .
od71956/2020_2021 : Supply,Installation,Testing and Commissioning of Intelligent Addressable monitor modules for Sprinkler Flow Switch, Fire doors, magnetic contacts & WLD monitoring complete as required as per specifications.The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device
od318995/2021_2022 : Supplying and drawing of cable Fire Retardant PVC insulated copper conductor<br>cable in the existing surface / recessed steel conduit of following pairs, cores and<br>size including connections and interconnections etc. as required.<br>speaker cable Two pair, 2-core, 1.5 sqmm
od318996/2021_2022 : Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS<br>outer sheath complete as required.
Two Way Talk Back & Public Address system
od84534/2020_2021 : Supply,installation,testing and commisioning of Public Address speaker with talk back facility 6 Watts with LMT and call switch, made out of powder coated CRC A sheet ,wall mounting type and to be installed at a height of not less than 150 CM from the finished floor levels, suitable for concealed mounting.
1.17.4 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
FIRE SHAFT DOORS
od66295/2020_2021 : Providing and fixing of Sheet metal duct door for the fire duct size 100 X70 ,100 X 104 cm fabricated from 16SWG GI CR Sheet & 18SWG shutter, sheets fully powder coated as per standard colour requirements of the Client with door handle, hinges and locking arrangements.
SIGNAGES
od66296/2020_2021 : Providing and installation in position the following type of sign boards made out of 3 mm thick "Opaque" PVC foam board with computer cut,Photoluminescent type self glowing vinyle painted foam board,complete with mirror fastners, glasscovering etc.Samples has to approved by the Architect before procuring the same. Floor indentification signages (ie,GROUNDFLOOR,FIRSTFLOOR,…etc.) at each stair enclosure on every floor,indicating the floor number in words,lettering size shall be7.5cm with contrasting colour from background.
od66298/2020_2021 : Providing and installation in position the following type of sign boards made out of 3 mm thick "Opaque" PVC foam board with computer cut,Photoluminescent type self glowing vinyle painted foam board,complete with mirror fastners, glasscovering etc.Samples has to approved by the Architect before procuring the same. Signage with printed IN CASE OF FIRE DO NOT USE LIFT,USE THE STAIRS,of 1.25 cm height letters in red with white background. The board shall be fixed at the height of 2 mts. from finished floor near lifts.
od66299/2020_2021 : Providing and installation in position self glowing Signage with printed FIRE EXTINGUISHER /FIREHYDRANT /FIREFIGHTING EQUIPMENTS OREDINSIDE, of 1.25 cm height letters in red with white background. The size of the board shall be 25 x35 cm and shall be fixed at the height of 2 mts. from finished floor near the fire ducts
od66301/2020_2021 : Providing and installation in position self glowing "FIREEXIT" / "EXIT" signboards with directional arrow markings of made of luminescent safety ,rigid sheet in green colour,photoluminescent type Samples has to be approved by the Architect before procuring the same.
od66302/2020_2021 : Supply and installation in position self glowing Signage with printed IN CASE OF FIRE BREAK GLASS, of 1.25cm height letters in red with white background.The size of the board shall be 10x15 cm and shall be fixed at the height of 2 mts. from finished floor near the Manual Call Points.
od66304/2020_2021 : Supply and installation of in position the signages "FIRE ORDER" it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerized cut, PVC Non-reflective self adhesive vinylepainted foamboard of 3'x4'. Samples has to approved by the Architect before procuring the same.A) ALERT THE SECURITY BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS. B) EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY, AND ASSEMBLE AT VARIOUS ASSEMBLY POITS. C) IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUITABLE PORTABLE FIRE EXTINGUISHER OR WATER FROM NEAREST HOSE REEL. D) BE CALM AND DO NOT GIVE ANY ROOM FOR PANIC. WALK, DO NOT RUN. E) IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION ,LAY FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM. F) TRY TO COVER YOUR FACE WITH A WET TOWEL TO AVOID BREATHING SMOKE OR OTHER TOXIC FUMES. ACTION BY SECURITY / RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR PUBLIC ADDRESS SYSTEM. A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM. B) INFORM FIRE CONTROL THROUGH ANYONE OF THE FOLLOWING PHONE NUMBERS:101 /………………….( Local fire station number) C) REFER EVACUATION PLAN.D) GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE. E) IN CASE OF CASUALTIES, CALL AMBULANCE (Local numbers:) PHONE : -----------------------
od66306/2020_2021 : Providing and installation in position Signage with printed SAFE ASSEMBLY AREA, of 1.25 cm height letters in red with white background.The size of the board shall be 40x30 cm and shall be fixed at the safe assembly areas demarked outside the building.
od66307/2020_2021 : Providing and installation in position 1 x 6W, 240 V, 1 ph, 50 Hz indoor type emergency exit light fixture with 1.3 AH 4hrs battery back up unit, LED Lamps, indicating Fire Exit, recess mounted type. 24hrs x 7days working conditional.
FIRE EXTINGUISHERS
od66309/2020_2021 : Supply and fixing of 2Kg CO2 Type Fire Extinguisher, Design, construction and testing as per IS 2190, Testingand Inspection - As per IS 15683, Squeeze Grip Type, ISI and CE marked on the Extinguisher, Hydrostatic pressure tested Certificate, Supplied with standard accessories.
od66310/2020_2021 : Supply and fixing of 4.5 Kg CO2 Type Fire Extinguisher, Design, construction and testing as per IS 2190, Testingand Inspection - As per IS 15683, Squeeze Grip Type, ISI and CE marked on the Extinguisher, Hydrostatic pressure tested Certificate, Supplied with standard accessories.
od66311/2020_2021 : Supply and fixing of 2Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher, Design, construction and testing as per IS 2190, Testingand Inspection - As per IS 15683, Squeeze Grip Type, ISI and CE marked on the Extinguisher, Hydrostatic pressure tested Certificate, Supplied with standard accessories.
od66312/2020_2021 : Supply and fixing of 4 Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 2190, Testingand Inspection - As per IS 15683, Squeeze Grip Type, ISI and CE marked on the Extinguisher, Hydrostatic pressure tested Certificate, Supplied with standard accessories.
od66313/2020_2021 : Supply and fixing of 9Kg Mechanical foam Type Fire Extinguisher storred pressure,Design, construction and testing as per IS 2190, Testingand Inspection - As per IS 15683, Squeeze Grip Type, ISI and CE marked on the Extinguisher, Hydrostatic pressure tested Certificate, Supplied with standard accessories.
od66314/2020_2021 : Supply and fixing of 2kg class K (wet chemical) Type Fire Extinguisher storred pressure , Design, construction and testing as per IS 2190, Testingand Inspection - As per IS 15683, Squeeze Grip Type, ISI and CE marked on the Extinguisher, Hydrostatic pressure tested Certificate, Supplied with standard accessories.
od66315/2020_2021 : Supply and fixing of 5 Kg ceiling mounted Fire Extinguisher Clean Agent HFC 236 FA, Stored Pressure Type, Pressure Gauge, Ozone Depletion Potential Zero, Gross Weight 3.7 Kg, Empty Weight 1.7 Kg,, Discharge time minimum 8 Seconds, Controllable discharge mechanism, Range minimum 2 Meters IS 15683
od66316/2020_2021 : Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of providing MS stand for 4 nos of fire buckes, or , duly painted over a coat of primer.
FIRE SUPPRESSION SYSTEM
od183356/2020_2021 : Supply,Installation, Testing and Commissioning of Clean Agent Storage Cylinder, high pressure seamless carbon steel cylinder, Test Pressure 334/ 250 Bar, working pressure 200/150 Bar and dia. 356/232 mm, PESO Approved, 100Ltrs.
od183405/2020_2021 : Supply, Installation, Testing and Commissioning of Valve Assembly (Brass), safety burst disc and a safety cap. Inlet & outlet port for actuation hose connection for operation during multi cylinder system to operate the inline master and slave cylinders.
od183406/2020_2021 : Supply, Installation, Testing and Commissioning of Pressure Gauge cum Switch for monitoring the cylinder pressure.
od183407/2020_2021 : Supply, Installation, Testing and Commissioning of HFC 227ea Gas (1,1,1,2,3,3,3 Hepta fluro propane), Zero ODP, Stored Pressure 25BAR.
od183441/2020_2021 : Supply, Installation, Testing and Commissioning of Electric Control Head (Solenoid actuator) used for releasing the GAS, Electrically operated, Voltage range 24VDC
od183442/2020_2021 : Supply, Installation, Testing and Commissioning of Manual (Mechanically Operated) Control Head (Brass) to operate the system pulling the mechanical lever with help of S.S. wire & Manual Pull station. Mounted over the Solenoid actuator.
od183443/2020_2021 : Supply, Installation, Testing and Commissioning of Manual Activation Mechanical box.
od183444/2020_2021 : Supply, Installation, Testing and Commissioning of SS Wire.<br>
od183438/2020_2021 : Supply, Installation, Testing and Commissioning of Wire Sleeve Aluminum.
od183439/2020_2021 : Supply, Installation, Testing and Commissioning of Corner Pulleys.
od183440/2020_2021 : Supply, Installation, Testing and Commissioning of End of Line for SS Wire.
od183437/2020_2021 : Supply,Installation, Testing and Commissioning ofBrass Discharge Nozzles are designed to provide the proper flow rate and distribution of HFC227ea agent to total flood a hazard area : 180 deg. / 360 deg. End connection - female thread type (NPT/BSPT).
od183433/2020_2021 : Supply, Installation, Testing and Commissioning of Flexible discharge Hose route the HFC227ea Agent from the storage cylinders to the discharge piping by a flexible rubber hose with wire braided reinforcements. This hose is connected to the discharge outlet of HFC 227 ea cylinder valve and terminated at the system piping or discharged manifold.
od183360/2020_2021 : Supply, Installation, Testing and Commissioning of A Conventional Detector Mounting Base associated with the CDX Range of Detectors and Beacons and is fully compatible with the Majority of existing conventional fire alarm control panels.
od183361/2020_2021 : Supply, Installation, Testing and Commissioning of A Conventional Rate of Rise Heat Detector (White) incorporating a 60°C fixed temperature element. The thermistor and linearising Circuits provide an accurate linear response Heat Detector. A third Terminal provides integral remote indicator output.
od183362/2020_2021 : Supply, Installation, Testing and Commissioning of A Conventional Detector Mounting Base associated with the CDX Range of Detectors and Beacons and is fully compatible with the Majority of existing conventional fire alarm control panels.
od183363/2020_2021 : Supply, Installation, Testing and Commissioning of A Conventional Photoelectric Smoke Detector (White), which is fully compatible with the majority of existing Conventional systems. A third terminal provides an integral remote indicator output.
od183364/2020_2021 : Supply, Installation, Testing and Commissioning of "Manual Abort Switch<br>The Manual Call Point is used as electrical activation device for gas extinguishing systems."<br>
od183365/2020_2021 : Supply, Installation, Testing and Commissioning of "Manual Release Switch:<br>The Manual Call Point operates as electrical emergency hold device For gas extinguishing systems.<br>
od183366/2020_2021 : Supply, Installation, Testing and Commissioning of Gas Release Panel with battery backup
od183367/2020_2021 : Supply, Installation, Testing and Commissioning of M S Container Strap for mounting and fixing the Agent containers to the wall.
od183431/2020_2021 : Supply, Installation, Testing and Commissioning of 2C x 1.5 Sq.mm CU. Armoured control / power Cable. Voltages grade 1100 Volts.
od183432/2020_2021 : Supply, Installation, Testing and Commissioning of An Electronic Conventional Sounder Beacon which can be installed internally.
od183422/2020_2021 : Supply, Installation, Testing and Commissioning of C.S./M.S. Seamless Piping, fittings (forged Screwed/socket weld up to 50NB) & M.S. supports e.g. angle, channel, plates clamps, etc. As per ASTM A-106, SCH. 40.
od248481/2020_2021 : Supply,Installation, Testing and Commissioning of Clean Agent Storage cylinder, high pressure seamless carbon steel cylinder, Test Pressure 300 Bar, working pressure 200 Bar and dia. 356 mm, PESO Approved, Capacity (in Ltrs.) for Cylinder. 140 ltrs
od248482/2020_2021 : Supply,Installation, Testing and Commissioning of Manifold fabricated from seamless pipe Pipe (S) : M.S. Seamless To ASTM A-106, SCH. 80 (3-way).
od248483/2020_2021 : Supply,Installation, Testing and Commissioning of C.S./M.S. Seamless Piping, fittings (forged Screwed/socekt weld upto 50NB) & M.S. supports e.g. angle, channel, plates clamps, etc. As per ASTM A-106, SCH. 40.
od183423/2020_2021 : Supply, Installation, Testing and Commissioning of Manifold fabricated from seamless pipe ,pipe(S):M.S. Seamless To ASTM A-106,SCH.80
od183420/2020_2021 : Supply, Installation, Testing and Commissioning of Actuation Adaptor
od183412/2020_2021 : Supply, Installation, Testing and Commissioning of Pneumatic Actuator<br><br>
od183414/2020_2021 : Supply, Installation, Testing and Commissioning of Discharge Hose<br>
od183416/2020_2021 : Supply, Installation, Testing and Commissioning of Actuation Hose
od183410/2020_2021 : Supply, Installation, Testing and Commissioning of Manifold Check Valve<br>
Electrical Works
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.55.1 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.3 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.28.1 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
1.28.3 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
1.28.4 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
1.28.5 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
od302230/2021_2022 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.<br>
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.34 : Supplying and fixing brass batten/ angle holder including connection etc. as required.
1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
1.39 : Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper cable, in PVC sleeve of suitable size on the floor / wall, or side of the table / door etc. as required.
1.40 : Providing and fixing plain 16/0.20 mm (0.50 sqmm) twin circular flexible FRLS PVC insulated, PVC sheathes copper cable direct on the wall with PVC clips etc as required.
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1.44 : Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
1.51 : Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
2.19 : Supplying and fixing 20 amps 415volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 amps "C" curve, TPMCB, in sheet enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
2.25 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.
5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
5.6 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
5.20 : Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
7.5.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm
7.6.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
7.6.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm
7.6.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 95 sq. mm and upto 185 sq. mm
7.6.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 185 sq. mm and upto 400 sq. mm
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
9.1.2 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
9.1.8 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 16 sq. mm (25mm)
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)
9.1.26 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)
1.14.4 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire
1.14.7 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
1.21.4 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm
1.21.5 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.50 mm
1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
2.13.3 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
15.1 : Supplying,Installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10 Amp, for mounting height up to 2.8 Mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming and site etc. complete as required
7.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm
7.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm
7.1.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm
9.1.36 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 50 sq. mm (35mm)
9.1.1 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
9.1.10 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 35 sq. mm (28mm)
10.4.3 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:240 sq. mm
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
7.9 : Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
14.13.1 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia
14.13.3 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia
11.3.1 : Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.Above 4.5 metre and upto 6.5 metre
11.4 : Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required
11.6.2 : Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.40 mm dia
od81830/2020_2021 : Providing RCC M20 grade mix for Cover Slab of 10cm thick using 20 mm crusher metal, 'M' sand of approved quality, including provision of hooks and M S Angles , hire charges for formwork, props,etc,placing in position vibrating the concrete, curing etc. including all lift and lead,etc complete as per specification. Size 80x95cm
od81823/2020_2021 : Supplying and laying of following size DWC HDPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.<br>63 mm dia (OD-63 mm & ID-51 mm nominal)
od81822/2020_2021 : Supplying and laying of following size DWC HDPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.<br>120 mm dia (OD-120 mm & ID-103 mm nominal)
7.5.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm
MCB, SWITCHGEARS & DBs
od81819/2020_2021 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (provision for MCCB as incomer & MCB as outgoings) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)<br>12 way Double door
od81820/2020_2021 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (provision for MCCB as incomer & MCB as outgoings) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)<br>8 way Double door
od81850/2020_2021 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (provision for MCCB as incomer & MCB as outgoings) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)<br>4 way Double door
MISCELLANEOUS ITEMS - DSR ITEM
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
10.17 : Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
10.18 : Providing and fixing circular / hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing .
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
2.38 : Filling with available fly ash and earth ( excluding rock) in trenches or embankment in layers ( each layer should not exceed 15 cm), with intermediate layer of compacted earth ( Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer - in- charge, including compacting each layer by rolling / ramming and watering, all complete as per drawing and direction of Engineer - in-charge
4.1.6 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
16.71 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer - in- Charge.
16.74.2 : 75 mm thick back filling for pitching including supplying of required materials and consolidation etc. complete with:Stone aggregate 20 mm nominal size
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
AUTOMATIC TRANSFER SWITCHES (ATS)
od80560/2020_2021 : AUTOMATIC TRANSFER SWITCHES (ATS)<br>Supply, installation, testing and commisioning of following rated four pole ATS switches in suitable size enclosure as per rating and size. Supply, installation, testing & commissioning of cubical type, dust and vermin proof, wall mounted, front operated, sheet steel enclosure with door sheet steel all round foamed-in PU seal with dipcoat primed, powder coated on the outside, textured paint with zinc-plated mounting plate. The colour shall be RAL 7035 with IP 66 protection, NEMA 4 protection category, IK08 impact resistance with hinged doors, all round solid construction, gland plate, mounting plate, Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Cutout provision for viewing the controller and source one - center off –source two switches shall be availiable in the enclosure for direct operation without opening the doors. RYB phase indication lamps shall also be provided in the enclosure from both sources. Provision for incoming cables and outgoing cables as per schematic to be also provided and provision for adding seperate UNCO module to be provided with each ATS for integrating ATS controller with SCADA software. Seperate provision for running control cable for communication with EMS shall also be provided<br>All transfer switches should be as per IEC60947-6-1 standards with minimum AC33B utilization category and with controller having RS485 port communicable with modbus for obtaining all parameters from controller for both sources. The automatic transfer switch shall consists of an intelligent controller and Modular load break switch which transfers the load to the secondary power source when it detects under/over voltage, under/over frequency, or phase failure.The switch shall have three possible operating positions (source one - center off –source two). The two sources can be isolated in the center off position. A position locking mechanism should also be provided. Phase loss sensing needs to be provided .<br>"The automatic transfer switches and accessories shall conform to the requirements of<br>• EN 60947-6-1 / IEC60947-6-1: transfer switching<br>• EN60947 -3 / IEC60947-3: Suitable for Isolation<br>• EN55022: Radiated and Conducted Emission,Class A<br>• EN61000-3-2: Harmonic Current Emission, Class A<br>• EN61000-3-3: Limits of Voltage fluctuation and Flicker<br>• EN 61000-4-5: Immunity to Surge<br>• EN 61000-4-4: Immunity to Electrical Fast Transient:<br>• EN61000-4-2: Immunity to Electrostatic Discharge<br>• EN61000-4-3: Immunity to Radiated Electric Fields<br>• EN 61000-4-6: Immunity to Continuous Conducted Interference<br>"<br>"The controller should pocess following features - Different Optional Modes (Source I priority /No Source priority), Controller Display Having Indicator -programming the features and settings, Switch position indicator lights, Source acceptability indicator lights on the front door panel.,Controller should be capable of detection of under and over voltage settings on source I and source II, Under and over frequency settings on source I and source II, Voltage unbalance detection between phases, under frequency transfer ,over frequency transfer, High frequency switching power supply, and wide power voltage range, Center-off with time delay and center-off with protection - The center-off time delay can be set to avoid large current rushes to inductive loads, Center-off with protection is available to protect critical loads <br>"<br>The ATS should have automatic and manual bypass operation. With electrical and mechnical interlocks to prevent both sources being connected simultaneously with high short circuit capability and rotaing dual contactor design to extinguish the arc quickly and effectively.(ASCO or equivalent) Add on RS485 Modbus Communication Module. BSEM(Breaker status & control Module) & IFM(Interface module) modules shall also be considered for integration with SCADA. ATS shall have priority as source 1 and will shift to source 2 when power fails in source 1 even if power is availiable in both sources priority shall be for source 1. Space provision fro installing of UNCO module for each ATS for communicating with SCADA software shall also be considered along with this scope in the enclosure (DIN rail mounted or Base mounted)<br>63A FP ATS
od80561/2020_2021 : AUTOMATIC TRANSFER SWITCHES (ATS)<br>Supply, installation, testing and commisioning of following rated four pole ATS switches in suitable size enclosure as per rating and size. Supply, installation, testing & commissioning of cubical type, dust and vermin proof, wall mounted, front operated, sheet steel enclosure with door sheet steel all round foamed-in PU seal with dipcoat primed, powder coated on the outside, textured paint with zinc-plated mounting plate. The colour shall be RAL 7035 with IP 66 protection, NEMA 4 protection category, IK08 impact resistance with hinged doors, all round solid construction, gland plate, mounting plate, Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Cutout provision for viewing the controller and source one - center off –source two switches shall be availiable in the enclosure for direct operation without opening the doors. RYB phase indication lamps shall also be provided in the enclosure from both sources. Provision for incoming cables and outgoing cables as per schematic to be also provided and provision for adding seperate UNCO module to be provided with each ATS for integrating ATS controller with SCADA software. Seperate provision for running control cable for communication with EMS shall also be provided<br>All transfer switches should be as per IEC60947-6-1 standards with minimum AC33B utilization category and with controller having RS485 port communicable with modbus for obtaining all parameters from controller for both sources. The automatic transfer switch shall consists of an intelligent controller and Modular load break switch which transfers the load to the secondary power source when it detects under/over voltage, under/over frequency, or phase failure.The switch shall have three possible operating positions (source one - center off –source two). The two sources can be isolated in the center off position. A position locking mechanism should also be provided. Phase loss sensing needs to be provided .<br>"The automatic transfer switches and accessories shall conform to the requirements of<br>• EN 60947-6-1 / IEC60947-6-1: transfer switching<br>• EN60947 -3 / IEC60947-3: Suitable for Isolation<br>• EN55022: Radiated and Conducted Emission,Class A<br>• EN61000-3-2: Harmonic Current Emission, Class A<br>• EN61000-3-3: Limits of Voltage fluctuation and Flicker<br>• EN 61000-4-5: Immunity to Surge<br>• EN 61000-4-4: Immunity to Electrical Fast Transient:<br>• EN61000-4-2: Immunity to Electrostatic Discharge<br>• EN61000-4-3: Immunity to Radiated Electric Fields<br>• EN 61000-4-6: Immunity to Continuous Conducted Interference<br>"<br>"The controller should pocess following features - Different Optional Modes (Source I priority /No Source priority), Controller Display Having Indicator -programming the features and settings, Switch position indicator lights, Source acceptability indicator lights on the front door panel.,Controller should be capable of detection of under and over voltage settings on source I and source II, Under and over frequency settings on source I and source II, Voltage unbalance detection between phases, under frequency transfer ,over frequency transfer, High frequency switching power supply, and wide power voltage range, Center-off with time delay and center-off with protection - The center-off time delay can be set to avoid large current rushes to inductive loads, Center-off with protection is available to protect critical loads <br>"<br>The ATS should have automatic and manual bypass operation. With electrical and mechnical interlocks to prevent both sources being connected simultaneously with high short circuit capability and rotaing dual contactor design to extinguish the arc quickly and effectively.(ASCO or equivalent) Add on RS485 Modbus Communication Module. BSEM(Breaker status & control Module) & IFM(Interface module) modules shall also be considered for integration with SCADA. ATS shall have priority as source 1 and will shift to source 2 when power fails in source 1 even if power is availiable in both sources priority shall be for source 1. Space provision fro installing of UNCO module for each ATS for communicating with SCADA software shall also be considered along with this scope in the enclosure (DIN rail mounted or Base mounted)<br>200A FP ATS
od80562/2020_2021 : AUTOMATIC TRANSFER SWITCHES (ATS)<br>Supply, installation, testing and commisioning of following rated four pole ATS switches in suitable size enclosure as per rating and size. Supply, installation, testing & commissioning of cubical type, dust and vermin proof, wall mounted, front operated, sheet steel enclosure with door sheet steel all round foamed-in PU seal with dipcoat primed, powder coated on the outside, textured paint with zinc-plated mounting plate. The colour shall be RAL 7035 with IP 66 protection, NEMA 4 protection category, IK08 impact resistance with hinged doors, all round solid construction, gland plate, mounting plate, Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Cutout provision for viewing the controller and source one - center off –source two switches shall be availiable in the enclosure for direct operation without opening the doors. RYB phase indication lamps shall also be provided in the enclosure from both sources. Provision for incoming cables and outgoing cables as per schematic to be also provided and provision for adding seperate UNCO module to be provided with each ATS for integrating ATS controller with SCADA software. Seperate provision for running control cable for communication with EMS shall also be provided<br>All transfer switches should be as per IEC60947-6-1 standards with minimum AC33B utilization category and with controller having RS485 port communicable with modbus for obtaining all parameters from controller for both sources. The automatic transfer switch shall consists of an intelligent controller and Modular load break switch which transfers the load to the secondary power source when it detects under/over voltage, under/over frequency, or phase failure.The switch shall have three possible operating positions (source one - center off –source two). The two sources can be isolated in the center off position. A position locking mechanism should also be provided. Phase loss sensing needs to be provided .<br>"The automatic transfer switches and accessories shall conform to the requirements of<br>• EN 60947-6-1 / IEC60947-6-1: transfer switching<br>• EN60947 -3 / IEC60947-3: Suitable for Isolation<br>• EN55022: Radiated and Conducted Emission,Class A<br>• EN61000-3-2: Harmonic Current Emission, Class A<br>• EN61000-3-3: Limits of Voltage fluctuation and Flicker<br>• EN 61000-4-5: Immunity to Surge<br>• EN 61000-4-4: Immunity to Electrical Fast Transient:<br>• EN61000-4-2: Immunity to Electrostatic Discharge<br>• EN61000-4-3: Immunity to Radiated Electric Fields<br>• EN 61000-4-6: Immunity to Continuous Conducted Interference<br>"<br>"The controller should pocess following features - Different Optional Modes (Source I priority /No Source priority), Controller Display Having Indicator -programming the features and settings, Switch position indicator lights, Source acceptability indicator lights on the front door panel.,Controller should be capable of detection of under and over voltage settings on source I and source II, Under and over frequency settings on source I and source II, Voltage unbalance detection between phases, under frequency transfer ,over frequency transfer, High frequency switching power supply, and wide power voltage range, Center-off with time delay and center-off with protection - The center-off time delay can be set to avoid large current rushes to inductive loads, Center-off with protection is available to protect critical loads <br>"<br>The ATS should have automatic and manual bypass operation. With electrical and mechnical interlocks to prevent both sources being connected simultaneously with high short circuit capability and rotaing dual contactor design to extinguish the arc quickly and effectively.(ASCO or equivalent) Add on RS485 Modbus Communication Module. BSEM(Breaker status & control Module) & IFM(Interface module) modules shall also be considered for integration with SCADA. ATS shall have priority as source 1 and will shift to source 2 when power fails in source 1 even if power is availiable in both sources priority shall be for source 1. Space provision fro installing of UNCO module for each ATS for communicating with SCADA software shall also be considered along with this scope in the enclosure (DIN rail mounted or Base mounted)<br>160A FP ATS
od80563/2020_2021 : AUTOMATIC TRANSFER SWITCHES (ATS)<br>Supply, installation, testing and commisioning of following rated four pole ATS switches in suitable size enclosure as per rating and size. Supply, installation, testing & commissioning of cubical type, dust and vermin proof, wall mounted, front operated, sheet steel enclosure with door sheet steel all round foamed-in PU seal with dipcoat primed, powder coated on the outside, textured paint with zinc-plated mounting plate. The colour shall be RAL 7035 with IP 66 protection, NEMA 4 protection category, IK08 impact resistance with hinged doors, all round solid construction, gland plate, mounting plate, Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Cutout provision for viewing the controller and source one - center off –source two switches shall be availiable in the enclosure for direct operation without opening the doors. RYB phase indication lamps shall also be provided in the enclosure from both sources. Provision for incoming cables and outgoing cables as per schematic to be also provided and provision for adding seperate UNCO module to be provided with each ATS for integrating ATS controller with SCADA software. Seperate provision for running control cable for communication with EMS shall also be provided<br>All transfer switches should be as per IEC60947-6-1 standards with minimum AC33B utilization category and with controller having RS485 port communicable with modbus for obtaining all parameters from controller for both sources. The automatic transfer switch shall consists of an intelligent controller and Modular load break switch which transfers the load to the secondary power source when it detects under/over voltage, under/over frequency, or phase failure.The switch shall have three possible operating positions (source one - center off –source two). The two sources can be isolated in the center off position. A position locking mechanism should also be provided. Phase loss sensing needs to be provided .<br>"The automatic transfer switches and accessories shall conform to the requirements of<br>• EN 60947-6-1 / IEC60947-6-1: transfer switching<br>• EN60947 -3 / IEC60947-3: Suitable for Isolation<br>• EN55022: Radiated and Conducted Emission,Class A<br>• EN61000-3-2: Harmonic Current Emission, Class A<br>• EN61000-3-3: Limits of Voltage fluctuation and Flicker<br>• EN 61000-4-5: Immunity to Surge<br>• EN 61000-4-4: Immunity to Electrical Fast Transient:<br>• EN61000-4-2: Immunity to Electrostatic Discharge<br>• EN61000-4-3: Immunity to Radiated Electric Fields<br>• EN 61000-4-6: Immunity to Continuous Conducted Interference<br>"<br>"The controller should pocess following features - Different Optional Modes (Source I priority /No Source priority), Controller Display Having Indicator -programming the features and settings, Switch position indicator lights, Source acceptability indicator lights on the front door panel.,Controller should be capable of detection of under and over voltage settings on source I and source II, Under and over frequency settings on source I and source II, Voltage unbalance detection between phases, under frequency transfer ,over frequency transfer, High frequency switching power supply, and wide power voltage range, Center-off with time delay and center-off with protection - The center-off time delay can be set to avoid large current rushes to inductive loads, Center-off with protection is available to protect critical loads <br>"<br>The ATS should have automatic and manual bypass operation. With electrical and mechnical interlocks to prevent both sources being connected simultaneously with high short circuit capability and rotaing dual contactor design to extinguish the arc quickly and effectively.(ASCO or equivalent) Add on RS485 Modbus Communication Module. BSEM(Breaker status & control Module) & IFM(Interface module) modules shall also be considered for integration with SCADA. ATS shall have priority as source 1 and will shift to source 2 when power fails in source 1 even if power is availiable in both sources priority shall be for source 1. Space provision fro installing of UNCO module for each ATS for communicating with SCADA software shall also be considered along with this scope in the enclosure (DIN rail mounted or Base mounted)<br>100A FP ATS <br>
od80564/2020_2021 : AUTOMATIC TRANSFER SWITCHES (ATS)<br>Supply, installation, testing and commisioning of following rated four pole ATS switches in suitable size enclosure as per rating and size. Supply, installation, testing & commissioning of cubical type, dust and vermin proof, wall mounted, front operated, sheet steel enclosure with door sheet steel all round foamed-in PU seal with dipcoat primed, powder coated on the outside, textured paint with zinc-plated mounting plate. The colour shall be RAL 7035 with IP 66 protection, NEMA 4 protection category, IK08 impact resistance with hinged doors, all round solid construction, gland plate, mounting plate, Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Cutout provision for viewing the controller and source one - center off –source two switches shall be availiable in the enclosure for direct operation without opening the doors. RYB phase indication lamps shall also be provided in the enclosure from both sources. Provision for incoming cables and outgoing cables as per schematic to be also provided and provision for adding seperate UNCO module to be provided with each ATS for integrating ATS controller with SCADA software. Seperate provision for running control cable for communication with EMS shall also be provided<br>All transfer switches should be as per IEC60947-6-1 standards with minimum AC33B utilization category and with controller having RS485 port communicable with modbus for obtaining all parameters from controller for both sources. The automatic transfer switch shall consists of an intelligent controller and Modular load break switch which transfers the load to the secondary power source when it detects under/over voltage, under/over frequency, or phase failure.The switch shall have three possible operating positions (source one - center off –source two). The two sources can be isolated in the center off position. A position locking mechanism should also be provided. Phase loss sensing needs to be provided .<br>"The automatic transfer switches and accessories shall conform to the requirements of<br>• EN 60947-6-1 / IEC60947-6-1: transfer switching<br>• EN60947 -3 / IEC60947-3: Suitable for Isolation<br>• EN55022: Radiated and Conducted Emission,Class A<br>• EN61000-3-2: Harmonic Current Emission, Class A<br>• EN61000-3-3: Limits of Voltage fluctuation and Flicker<br>• EN 61000-4-5: Immunity to Surge<br>• EN 61000-4-4: Immunity to Electrical Fast Transient:<br>• EN61000-4-2: Immunity to Electrostatic Discharge<br>• EN61000-4-3: Immunity to Radiated Electric Fields<br>• EN 61000-4-6: Immunity to Continuous Conducted Interference<br>"<br>"The controller should pocess following features - Different Optional Modes (Source I priority /No Source priority), Controller Display Having Indicator -programming the features and settings, Switch position indicator lights, Source acceptability indicator lights on the front door panel.,Controller should be capable of detection of under and over voltage settings on source I and source II, Under and over frequency settings on source I and source II, Voltage unbalance detection between phases, under frequency transfer ,over frequency transfer, High frequency switching power supply, and wide power voltage range, Center-off with time delay and center-off with protection - The center-off time delay can be set to avoid large current rushes to inductive loads, Center-off with protection is available to protect critical loads <br>"<br>The ATS should have automatic and manual bypass operation. With electrical and mechnical interlocks to prevent both sources being connected simultaneously with high short circuit capability and rotaing dual contactor design to extinguish the arc quickly and effectively.(ASCO or equivalent) Add on RS485 Modbus Communication Module. BSEM(Breaker status & control Module) & IFM(Interface module) modules shall also be considered for integration with SCADA. ATS shall have priority as source 1 and will shift to source 2 when power fails in source 1 even if power is availiable in both sources priority shall be for source 1. Space provision fro installing of UNCO module for each ATS for communicating with SCADA software shall also be considered along with this scope in the enclosure (DIN rail mounted or Base mounted)<br>250A FP ATS <br>
od86/2021_2022 : AUTOMATIC TRANSFER SWITCHES (ATS)<br>Supply, installation, testing and commisioning of following rated four pole ATS switches in suitable size enclosure as per rating and size. Supply, installation, testing & commissioning of cubical type, dust and vermin proof, wall mounted, front operated, sheet steel enclosure with door sheet steel all round foamed-in PU seal with dipcoat primed, powder coated on the outside, textured paint with zinc-plated mounting plate. The colour shall be RAL 7035 with IP 66 protection, NEMA 4 protection category, IK08 impact resistance with hinged doors, all round solid construction, gland plate, mounting plate, Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Cutout provision for viewing the controller and source one - center off –source two switches shall be availiable in the enclosure for direct operation without opening the doors. RYB phase indication lamps shall also be provided in the enclosure from both sources. Provision for incoming cables and outgoing cables as per schematic to be also provided and provision for adding seperate UNCO module to be provided with each ATS for integrating ATS controller with SCADA software. Seperate provision for running control cable for communication with EMS shall also be provided<br>All transfer switches should be as per IEC60947-6-1 standards with minimum AC33B utilization category and with controller having RS485 port communicable with modbus for obtaining all parameters from controller for both sources. The automatic transfer switch shall consists of an intelligent controller and Modular load break switch which transfers the load to the secondary power source when it detects under/over voltage, under/over frequency, or phase failure.The switch shall have three possible operating positions (source one - center off –source two). The two sources can be isolated in the center off position. A position locking mechanism should also be provided. Phase loss sensing needs to be provided .<br>"The automatic transfer switches and accessories shall conform to the requirements of<br>• EN 60947-6-1 / IEC60947-6-1: transfer switching<br>• EN60947 -3 / IEC60947-3: Suitable for Isolation<br>• EN55022: Radiated and Conducted Emission,Class A<br>• EN61000-3-2: Harmonic Current Emission, Class A<br>• EN61000-3-3: Limits of Voltage fluctuation and Flicker<br>• EN 61000-4-5: Immunity to Surge<br>• EN 61000-4-4: Immunity to Electrical Fast Transient:<br>• EN61000-4-2: Immunity to Electrostatic Discharge<br>• EN61000-4-3: Immunity to Radiated Electric Fields<br>• EN 61000-4-6: Immunity to Continuous Conducted Interference<br>"<br>"The controller should pocess following features - Different Optional Modes (Source I priority /No Source priority), Controller Display Having Indicator -programming the features and settings, Switch position indicator lights, Source acceptability indicator lights on the front door panel.,Controller should be capable of detection of under and over voltage settings on source I and source II, Under and over frequency settings on source I and source II, Voltage unbalance detection between phases, under frequency transfer ,over frequency transfer, High frequency switching power supply, and wide power voltage range, Center-off with time delay and center-off with protection - The center-off time delay can be set to avoid large current rushes to inductive loads, Center-off with protection is available to protect critical loads <br>"<br>The ATS should have automatic and manual bypass operation. With electrical and mechnical interlocks to prevent both sources being connected simultaneously with high short circuit capability and rotaing dual contactor design to extinguish the arc quickly and effectively.(ASCO or equivalent) Add on RS485 Modbus Communication Module. BSEM(Breaker status & control Module) & IFM(Interface module) modules shall also be considered for integration with SCADA. ATS shall have priority as source 1 and will shift to source 2 when power fails in source 1 even if power is availiable in both sources priority shall be for source 1. Space provision fro installing of UNCO module for each ATS for communicating with SCADA software shall also be considered along with this scope in the enclosure (DIN rail mounted or Base mounted)<br>400A FP ATS <br>
DIESIEL GENERATORS, ALLIED WORKS AND EXHAUST PIPES
od71819/2020_2021 : Supply and installation of 3 nos 990L capacity day tanks to be provided in a closed enclosure. The capacity of the fuel tank supplied has to be capable for 8 Hrs continuous operations @ 80% load. Supply shall include • Fuel tank pipe from ibuilt tank to day tank and return, Refueling and drainage plugs, welding sleeves and fixing material, insulation, couplers and all accesries along with automatic pumping system for fuel refilling should be considered in ths scope of work including necessary length fuel pipe as per manufacturer recommendation and accesories for providing DG fuel piping to DG day tanks for all DG sets, providing couplers, insulation, installation and all accesories required, supply and providing of pumping system from day tank with automatic operation using controller, connecting to pump, providing connections complete as required. Fuel piping from storage shall be done in such a way that the piping is not permanantly connected to the day tanks, it can be removed after refueling. Hence total capacity of fuel tank for DG set will not exceed permissible limits.<br>
od71820/2020_2021 : Supply & providing insulation for exhaust pipe with thermal insulation and providing aluminium cladding as per standards.<br>
od71821/2020_2021 : Supply & providing thermal insulation for silencer with inner glass wool and providing aluminium cladding for DG set as per standards.<br>
od71823/2020_2021 : EXHAUST PIPES<br>Supply, erection, commissioning of additional length of exhaust pipes with long radius bend from residential silencer with necessary clamps, fixtures, civil works and painted with heat resistant, rust proof, bituminous paint of approved colors to a maximum of 10 m in stages of following sizes including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. It is also recommended that horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipe height shall be 3m more than the top of any adjacent building withing 10m radius of the exhaust.<br>250mm dia <br>
od71831/2020_2021 : EXHAUST PIPES<br>Supply, erection, commissioning of additional length of exhaust pipes with long radius bend from residential silencer with necessary clamps, fixtures, civil works and painted with heat resistant, rust proof, bituminous paint of approved colors to a maximum of 10 m in stages of following sizes including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. It is also recommended that horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipe height shall be 3m more than the top of any adjacent building withing 10m radius of the exhaust.<br>300mm dia <br>
od72153/2020_2021 : Supply and installing of MS support etc using structural steel work (riveted, bolted or welded) in built up sections, including angle, channel, I section, necessary nut and bolt and all required accessories including cutting, hoisting, fixing in position and applying 2 coats of primer and 2 coats of enamel paint of approved quality etc as required. <br>
od72154/2020_2021 : For supporting DG exhaust pipe on wall surface with sufficent supporting structure using GI pipes medium section) having diameters 32, 40 & 65mm by welding including applying priming coat and heat resistant paint etc<br>
od72155/2020_2021 : DG set commisioning including Trial run of DG set for 6 hrs. on no-load and variable load condition and to record the parameters as per prescribed format as per manufacturer standards. Cost of consumable ( fuel oil, lube oil, etc.) to be borne by Contractor. This shall also include first fill of diesel for commisiong of the DG set. Full tank Diesel shall be filled for initial commisioning.<br>
od72156/2020_2021 : Providing and fixing M.S. grills using suitable sections on to the walls with sufficient bearings on walls including applying a priming coat with approved steel primer and including cost and conveyance of all materials hire and labour charges etc. complete.<br>
od72157/2020_2021 : Supply, fabricate, handle and erect Fabricated G I duct, complete with all necessary fittings and accessories etc. as reqd. and including supports and necessary fixing components as required for complete installation for DG hot air exhaust<br>
od80556/2020_2021 : Fabrication, supply & installation of DG adaptor box for 650kVA, including painting etc as per technical specifications provided including all accessories for complete installation for extending of DG bus bar, including bus bar extension and making ease for providing cable terminations complete as required<br>
LIGHT & FAN FIXTURES
od72435/2020_2021 : INTERIOR LIGHT FIXTURES <br>Supply of round surface mounted LED designer Downlighter with pressure die cast aluminium-alloy housing with corrosion resistance powder coating using nano technology. Injection moulded UV stabilized diffuser for optimum light tranmission including all accesores as required. (Make - Lighting Technologies Lunar Mid 9W 5700K or equivalent) <br>
od72436/2020_2021 : INTERIOR LIGHT FIXTURES <br>Supply of round surface mounted LED designer Downlighter with a nominal system lumen output of 1200 lumens and a minimum system efficacy >100 lm/W. The luminaire shall have a rated system lifetime of 30,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF > 0.9. The luminaire housing should made of plastic with a polycarbonate reflector and a high quality diffuser. The total power consumption should not exceed 12W (including driver).The luminaire and driver must be BIS aprroved. (Make :Philips SLEEK SURFACE SM250C LED12S PSU or equivalent)<br>
od72437/2020_2021 : INTERIOR LIGHT FIXTURES <br>Supply of recess mounted LED downlighter with a circular form factor with a power consumption of 13.5 W and a system level lumen output of 1500 lumens and a system level luminous efficacy >110 lm /W. The luminaire shall have a pressure die cast aluminium housing, a polycarbonate diffuser and a sleek design of product height not more than 40 mm. The luminaire shall have a CCT of 6500 K , CRI>80, power factor >0.9 and THD <10 %. The luminaire shall have a non integral LED driver with 50,000 burning hours as per L70B50 criteria, 2.5 kV surge protection. The luminaire shall be EMI/ EMC compliant and should have a Class B serviceability (The driver can be replaced at site level).The luminaire and driver mute be BIS aprroved and test certificates of LM79 and LM80 reports shall be submitted (Make: Philips DN296B LED15S 6500 PSU or equivalent)<br>
od72438/2020_2021 : INTERIOR LIGHT FIXTURES <br>Supply of round surface mounted LED designer downlighter with a nominal system lumen output of 1600 lumens and a minimum system efficacy >100 lm/W. The luminaire shall have a rated system lifetime of 30,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF > 0.9. The luminaire housing should made of plastic with a polycarbonate reflector and a high quality diffuser. The total power consumption should not exceed 15W (including driver).The luminaire and driver must be BIS aprroved (Make : Philips Sleek surface SM251C LED16S PSU or equivalent)<br>
od72439/2020_2021 : INTERIOR LIGHT FIXTURES <br>Supply of recess mounted soft glowing LED downlighter with a circular form factor with a power consumption of 14.5 W and a system level lumen output of 1500 lumens and a system level luminous efficacy >100 lm /W, UGR <=19. The luminaire shall have a pressure die cast aluminium housing, a prismatic diffuser with very high transperancy and should be sleek. The luminaire shall have a CCT of 6500 K , CRI>80, power factor >0.9 and THD <10 %. The luminaire shall have a non integral LED driver with 50,000 burning hours as per L70B50 criteria, 2.5 kV surge protection. The luminaire shall be EMI/ EMC compliant and should have a Class B serviceability (The driver can be replaced at site level).The luminaire and driver mute be BIS aprroved and test certificates of LM79 and LM80 reports shall be submitted (Make: Philips DN296B LED15S 6500 PSU SG or equivalent) <br>
od72440/2020_2021 : INTERIOR LIGHT FIXTURES <br>Supply of LED bulkhead luminaire that fits seamlessly in a variety of applicatications, consuming a power of 6 W , lumen output greater than 700 lumens with a system efficacy > 110 lm/W. The luminaire shall housing shall be made of High Pressure diecast aluminum with a UV stablised polycarbonate diffuser, IP 66 and IK 09 protection. The luminaire shall have a power factor > 0.9 and shall have 50,000 burning hours as per L70 criteria. The luminaire shall be BIS certified and shall comply all IEC safety requirements and test certificates of LM79 and LM80 reports shall be submitted. (Make : Philips WT202W LED6S CW PSU S1 PC or equivalent) <br>
od72441/2020_2021 : INTERIOR LIGHT FIXTURES <br>Supply of 11 W white colour decorative wall lights with Aluminium finish for mirror light application. (Make - Philips Mirror Lights Model No. 31167 or equivalent)<br>
od72442/2020_2021 : INTERIOR LIGHT FIXTURES <br>Supply of 4 feet surface mounted battern type luminaire with a power consumption not more than 17 W, luminaire lumen output of 2000 lumens, luminaire efficacy > 120 lm/W with an operanting voltage range from 140 V - 270 V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and a sleek design. The luminaire shall have a CCT of 6500 K , CRI > 80, power factor >0.95, SDCM < 5, THD <10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content <5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 kV. The luminaire shall have Class - 1 Electrical Insulation, Class - B Serviceability (The driver can be replaced at site level). The luminaire and driver shall be BIS aprroved and test certificates of LM79 and LM80 reports shall be submitted. (Make: Philips BN308 LED20S 6500 L120 PSU WH or equivalent) <br>
od72443/2020_2021 : INTERIOR LIGHT FIXTURES <br>Supply of recess mounted LED downlighter with a circular form factor with a power consumption of 9 W and a system level lumen output of 1000 lumens and a system level luminous efficacy >110 lm /W. The luminaire shall have a pressure die cast aluminium housing, a polycarbonate diffuser and a sleek design of product height not more than 40 mm. The luminaire shall have a CCT of 6500 K , CRI>80, power factor >0.9 and THD <10 %. The luminaire shall have a non integral LED driver with 50,000 burning hours as per L70B50 criteria, 2.5 kV surge protection. The luminaire shall be EMI/ EMC compliant and should have a Class B serviceability (The driver can be replaced at site level).The luminaire and driver shall be BIS aprroved and test certificates of LM79 and LM80 reports shall be submitted.(Make: Philips DN295B LED10S 6500 PSU or equivalent) <br>
od72684/2020_2021 : INTERIOR LIGHT FIXTURES <br>Supply of 4 feet surface mounted battern type luminaire with inbuilt occupancy sensor with a power consumption not more than 34 W, luminaire lumen output of 4000 lumens, luminaire efficacy > 120 lm/W with an operanting voltage range from 140 V - 270 V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and a sleek design with width not more than . The luminaire must be able to dim its light output to 50 % if there is no movement The luminaire shall have a CCT of 6500 K , CRI > 80, power factor >0.95, SDCM < 5, THD <10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content <5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 kV. The luminaire shall have Class - 1 Electrical Insulation, Class - B Serviceability (The driver can be replaced at site level). The luminaire and driver shall be BIS aprrovedand test certificates of LM79 and LM80 reports shall be submitted (Make: Philips BN308 LED40S 6500 L120 PIR WH or equivalent) <br>
od72685/2020_2021 : INTERIOR LIGHT FIXTURES <br>Supply of 4 feet surface mounted battern type luminaire with a power consumption not more than 34 W, luminaire lumen output of 4000 lumens, luminaire efficacy > 120 lm/W with an operanting voltage range from 140 V - 270 V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and a sleek design with width not more than . The luminaire shall have a CCT of 6500 K , CRI > 80, power factor >0.95, SDCM < 5, THD <10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content <5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 kV. The luminaire shall have Class - 1 Electrical Insulation, Class - B Serviceability (The driver can be replaced at site level). The luminaire and driver shall be BIS aprroved and test certificates of LM79 and LM80 reports shall be submitted (Make: Philips BN308 LED40S 6500 L120 PSU WH or equivalent) <br>
od72686/2020_2021 : INTERIOR LIGHT FIXTURES <br>Supply of 4 feet surface mounted battern type luminaire with inbuilt occupancy sensor with a power consumption not more than 17 W, luminaire lumen output of 2000 lumens, luminaire efficacy > 120 lm/W with an operanting voltage range from 140 V - 270 V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and a sleek design with width not more than . The luminaire must be able to dim its light output to 50 % if there is no movement The luminaire shall have a CCT of 6500 K , CRI > 80, power factor >0.95, SDCM < 5, THD <10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content <5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 kV. The luminaire shall have Class - 1 Electrical Insulation, Class - B Serviceability (The driver can be replaced at site level). The luminaire and driver shall be BIS aprroved and test certificates of LM79 and LM80 reports shall be submitted (Make: Philips BN308 LED20S 6500 L120 PIR WH or equivalent) <br>
od72735/2020_2021 : INTERIOR LIGHT FIXTURES <br>Supply of 34 W recess mounted soft glowing 2' x 2' LED luminaire with system light output greater than 3600 lumens and system efficacy >110 lm/W, UGR<19. The luminaire must be energy efficient with CRI>80, CCT - 6500, pf > 0.95, THD <10% SDCM<5. The luminaire shall be flicker free with a ripple content less than 5 %. The luminaire housing shall be made of CRCA and prismatic polystyrene diffuser with high transperancy coefficient and a lifetime of 50,000 burning hours as per L70B50 criteria, 4 kV internal surge protection. The luminaire must be BIS certified and must have LM79 and LM80 reports from NABL certified labs (Make - Philips RC380B LED36S-6500 PSU OD SG or equivalent)<br>
od72736/2020_2021 : INTERIOR LIGHT FIXTURES <br>"Supply of 32W bottom opening clean room LED luminaire with system light output greater than 3600 lumens and system efficacy >105 lm/W. . The luminaire must be energy efficient with CRI>80, CCT - 6500, pf > 0.95, THD <10% SDCM<5, IP65 protection. The luminaire housing shall be made of CRCA and acrylic diffuser with IK07 protection. The luminaire shall have a lifetime of 50,000 burning hours as per L70B50 criteria, 4 kV inbuilt surge protection. The luminaire mounting shall be through M8 high tension rod and must have a gasket on the edge to get completely sealed in the ceiling. The luminaire must not be affected by EMI and EMC interferences. The luminaire must be BIS certified and must have LM79 and LM80 reports from NABL certified labs<br>(Make : Philips CR652B LED36S-6500 PSU CA TO W60L60 WH or equivalent) "<br>
od72737/2020_2021 : INTERIOR LIGHT FIXTURES <br>Supply of LED track mounting fixture equivalent of 20 W using efficient optics with system lumen efficacy should be atleast 100 lm/W, CCT- 4000 K , CRI >80. The luminaire shall have a lifetime of 40,000 hours burning life as per L70B50 criteria at an ambient temperature of 45 deg. C. The housing shall be made of diecast aluminium with efficient optics with a beam angle of 36 deg and excellent thermal management system.The product should have Inbuilt gear and it should have Zero maintenance, and Zero mercury.The luminaire must be BIS certified and must have LM79 and LM80 reports from NABL certified labls (Make: Philips ST271T LED20/840 PSU WB or equivalent)<br>
od72738/2020_2021 : INTERIOR LIGHT FIXTURES <br>Supply of 28 W 2' x 2' LED luminaire with surface mounted frame having a system light output greater than 3600 lumens and system efficacy >125 lm/W. The luminaire must be energy efficient with CRI>80, CCT - 6500, pf > 0.95, THD <10% SDCM<5, IP20 protection. The luminaire shall be flicker free with a ripple content less than 5 %. The luminaire housing shall be made of CRCA and diffuser material of PS and a lifetime of 50,000 burning hours as per L70B50 criteria, 4 kV internal surge protection. The luminaire must be BIS certified and must have LM79 and LM80 reports from NABL certified labs (Make : Philips RC380B LED36S-6500 PSU with surface mount frame or equivalent) <br>
od72739/2020_2021 : INTERIOR LIGHT FIXTURES <br>Supply of 28 W recess mounted 2' x 2' LED luminaire with system light output greater than 3600 lumens and system efficacy >125 lm/W. The luminaire must be energy efficient with CRI>80, CCT - 6500, pf > 0.95, THD <10% SDCM<5, IP20 protection. The luminaire shall be flicker free with a ripple content less than 5 %. The luminaire housing shall be made of CRCA and diffuser material of PS and a lifetime of 50,000 burning hours as per L70B50 criteria, 4 kV internal surge protection. The luminaire must be BIS certified and must have LM79 and LM80 reports from NABL certified labs (Make : Philips RC380B LED36S-6500 PSU or equivalent) <br>
od72865/2020_2021 : INTERIOR LIGHT FIXTURES <br>"Supply of LED adjustable luminare for recess application, with pressure die-cast aluminium alooy hosuing, corrosion resistance powder coating using nano technology. UV stabilized transparent cover with reflector, rotatable on both axis and with various beam angles including all accesories as required. (Make - Lighting technologies -RWR0D01557NDWEE024 Revolve Mid WALL WASHER 15W 5700K CCT NON DIM WHITE (PC)<br>ECO BOON 24 Beam Angle or equivalent)"<br>
od72866/2020_2021 : INTERIOR LIGHT FIXTURES <br>Supply, installation, testing and commisioning of 3mtr Track for track light including all accessories required, mounting on ceiling etc complete as required (Make Philips RCS170 or equivalent) <br>
od73116/2020_2021 : EXTERIOR LIGHT FIXTURES <br>Supply, fixing, testing and commissioning of 6 M octagonal poles of approved Make having top dia 70 mm, bottom dia 130 mm, Sheet thickness 3 mm, pitch circle dia (PCD) of 200 mm, Base plate dimentions 200mm length x 200mm bredth x 12mm thickness, EN8 grade Foundation bolts of size 4 x 20 mm dia, having bolt length of 450 mm. The Octagonal Poles shall be designed to withstand the maximum wind speed as per IS 875. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The octagonal Poles shall have door of approximate 500 mm length at the elevation of 500 mm from the Base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement. There shall also be suitable arrangement for the purpose of earthing. Material Octagonal Poles HT Steel Conforming to grade S355JO.Base Plate Fe 410 conforming to IS 226 / IS 2062Foundation Bolts EN.8 grade (Make - Bajaj, Lighting Technologies, GE or equivalent). The poles shall be hot dip galvanised as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 85 micron. The galvanizing shall be done in single dipping. The pole shall include two arms for fixing including supply of 60 W LED street light luminaire with system efficacy greater than 120 lm/W, CRI >70 , CCT-5700 K , pf>0.95. The luminaire must have a IP66 protection and IK07 protection, 4kV internal surge protection. The luminaire must have feature for auto high cut off @ 325 ± 15V & Auto Restart. The luminaire must be BIS certified and must have LM79 and LM80 reports from NABL accredited labs, including all accesories required for complete installation. The fixture shall be pressure die cast aluminium-alloy housing with corrosion resistance powder coating using nano technology with UV stabilized injection moulded PC cover for optimum light transmission (Make Lighting Technologies Adornis Min 60W 5700K LED pole mounted fixture or equivalent)<br>
od73117/2020_2021 : EXTERIOR LIGHT FIXTURES <br>Supply and installation of GI aesthetically good looking tubular pole 3m height, hot dip galvanised for mounting of Post top luminiare applied with primer and paint<br>
od73118/2020_2021 : EXTERIOR LIGHT FIXTURES <br>Supply, installation, testing and commisioning of LED Post Top with a system lumen output of ≥ 2300 lumens .The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 3000K and CRI > 70. The luminaire shall meet IP65 with THD < 20% and PF > 0.9. The luminaire shall have closed diffused optics with polycarbonate diffuser board. The total power consumption should not exceed 27W (including driver). The luminaire shall be made up of aluminium die cast housing with polycarboate cover. Luminaire should be with minimum system efficacy of ≥ 85Lumen/Watt. Luminaire should withstand THD less than 10% and should have power factor > 0.90. Driver efficiency should be 85% . Luminaire should comply with all the required IEC standards and should operate in a voltage range of 220-240 volts AC. The luminaire shall be dark grey in color. The LEDs used shall be of high power LEDs. The driver shall be potted type. The luminaire shall be BIS tested and approved and test certificates of LM79 and LM80 reports shall be submitted. (Make : Philips BGP161 LED23WW PSU or equivalent)<br>
od73349/2020_2021 : Exhaust Fan<br>Supply of exhaust fan of 250mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required, including all accessories as required for complete installation including shutter etc. complete as required.(havells, Ventil Air DX White or equivalent)<br>
od73350/2020_2021 : Supplying 5 star rated , BEE certified 26W, ceiling fan with BLDC motor, with super enamelled copper wire winding, 230 V, single phase 50 HZ remote control operated fan with 1200mm sweep and 3 blades including all accessories as required with remote and standard length downrod all accesories required for complete installation (Havells Efficienca Neo or equivalent)<br>
od73351/2020_2021 : Wall Fan<br>Supply, installation, testing and commisiong of 450mm sweep wall fan on surface including mouting and providing all accessories required for complete installation, testing, commisioning etc as required complete (Havells Airboll Hi-Speed or equivalent)<br>
od73352/2020_2021 : Exhaust Fan Heavy duty<br>Supply of heavy duty exhaust fan of 450mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required, including all accessories as rquired for complete installation incluidng shutter etc complete as required.(havells, TurboForce SP or equivalent)<br>
od76018/2020_2021 : EXTERIOR LIGHT FIXTURES <br>Supply, installation, testing and commisioning of LED bollard with system power of 10W delivering 340 lumens. The luminaires shall be with CRI > 75 with CCT of 3000K. The light distribution shall be symmetric with system efficacy of > 34 lm/ W. The housing shall be of LM6 pressure die cast aluminium and diffuser shall be of Polycarbonate. The luminaire shall be with IP 65 and IK 10 rating. The light emittance area of he bollard should be cylindrical and shall be 100 mm dia and 100 in mm. The ULOR of the luminaire shall not be more than 50 % at standard 0 tilt condition. The luminaire shall be IEC compliant and shall have a surge protection of 4 kV. The luminaire shall be with lifetime of 50K hrs @L70 @35°C. The luminaire shall be operable from 140-270V AC with PF > 0.95 and THD < 20%. The luminaire shall have Class -1 Electrical safety and be BIS tested and approved and test certificates of LM79 and LM80 reports shall be submitted. (Make: Philips BCP151 LED150/WW PSU or equivalent)<br>
od76019/2020_2021 : EXTERIOR LIGHT FIXTURES <br>Supply, fixing, testing and commissioning of 8 M octagonal poles of approved Make having top dia 70 mm, bottom dia 130 mm, Sheet thickness 3 mm, pitch circle dia (PCD) of 200 mm, Base plate dimentions 200mm length x 200mm bredth x 16mm thickness, EN8 grade Foundation bolts of size 4 x 20 mm dia, having bolt length of 600 mm. The Octagonal Poles shall be designed to withstand the maximum wind speed as per IS 875. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The octagonal Poles shall have door of approximate 500 mm length at the elevation of 500 mm from the Base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement. There shall also be suitable arrangement for the purpose of earthing. Material Octagonal Poles HT Steel Conforming to grade S355JO.Base Plate Fe 410 conforming to IS 226 / IS 2062Foundation Bolts EN.8 grade (Make - Bajaj, Lighting Technologies, GE or equivalent). The poles shall be hot dip galvanised as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 85 micron. The galvanizing shall be done in single dipping. The pole shall include one arm for fixing including supply of 90 W LED street light luminaire with system efficacy greater than 120 lm/W. The luminaire must have a IP66 protection and IK07 protection, 4kV internal surge protection. The luminaire must have feature for auto high cut off @ 325 ± 15V & Auto Restart. The luminaire must be BIS certified and must have LM79 and LM80 reports from NABL accredited labs, including all accesories required for complete installation. The fixture shall be pressure die cast aluminium-alloy housing with corrosion resistance powder coating using nano technology with UV stabilized injection moulded PC cover for optimum light transmission (Make Lighting Technologies Adornis INT 90W 5700K LED pole mounted fixture or equivalent)<br>
od76034/2020_2021 : EXTERIOR LIGHT FIXTURES <br>Supply, fixing, testing and commissioning of 0.5 M arm having dia max 43mm for fixing exterior light fixture of approved make (Model No: Bajaj BOP - 1030 or equivalent) designed to withstand the maximum wind speed as per IS 875. The arms shall be hot dip galvanised as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 85 micron. The galvanizing shall be done in single dipping. The arms shall be capable for fixing one number Supply of 25 W LED street light luminaire with system efficacy greater than 120 lm/W and system lumen output greater than 2800 lumens, CRI >70 , CCT-5700 K , pf>0.95. The luminaire must have a IP66 protection and IK07 protection, 4kV internal surge protection. The luminaire must have feature for auto high cut off @ 325 ± 15V & Auto Restart. The luminaire must be BIS certified and must have LM79 and LM80 reports from NABL accredited labs, including all accesories required for complete installation. The fixture shall be pressure die cast aluminium-alloy housing with corrosion resistance powder coating using nano technology with UV stabilized injection moulded PC cover for optimum light transmission (Make Lighting Technologies Adornis Min 25W 5700K LED pole mounted fixture or equivalent) including all accesories required for complete installation as instructed by engineer in charge/consultant. <br>
od139515/2020_2021 : Supply, fixing, testing and commissioning of 6 M octagonal poles of approved Make having top dia 70 mm, bottom dia 130 mm, Sheet thickness 3 mm, pitch circle dia (PCD) of 200 mm, Base plate dimentions 200mm length x 200mm bredth x 12mm thickness, EN8 grade Foundation bolts of size 4 x 20 mm dia, having bolt length of 450 mm. The Octagonal Poles shall be designed to withstand the maximum wind speed as per IS 875. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The octagonal Poles shall have door of approximate 500 mm length at the elevation of 500 mm from the Base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement. There shall also be suitable arrangement for the purpose of earthing. Material Octagonal Poles HT Steel Conforming to grade S355JO.Base Plate Fe 410 conforming to IS 226 / IS 2062Foundation Bolts EN.8 grade (Make - Bajaj, Lighting Technologies, GE or equivalent). The poles shall be hot dip galvanised as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 85 micron. The galvanizing shall be done in single dipping. The pole shall include one arm for fixing including supply of 60 W LED street light luminaire with system efficacy greater than 120 lm/W, CRI >70 , CCT-5700 K , pf>0.95. The luminaire must have a IP66 protection and IK07 protection, 4kV internal surge protection. The luminaire must have feature for auto high cut off @ 325 ± 15V & Auto Restart. The luminaire must be BIS certified and must have LM79 and LM80 reports from NABL accredited labs, including all accesories required for complete installation. The fixture shall be pressure die cast aluminium-alloy housing with corrosion resistance powder coating using nano technology with UV stabilized injection moulded PC cover for optimum light transmission (Make Lighting Technologies Adornis Min 60W 5700K LED pole mounted fixture or equivalent)
od193193/2020_2021 : Supply, fixing, testing and commissioning of 8 M octagonal poles of approved Make having top dia 70 mm, bottom dia 130 mm, Sheet thickness 3 mm, pitch circle dia (PCD) of 200 mm, Base plate dimentions 200mm length x 200mm bredth x 16mm thickness, EN8 grade Foundation bolts of size 4 x 20 mm dia, having bolt length of 600 mm. The Octagonal Poles shall be designed to withstand the maximum wind speed as per IS 875. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The octagonal Poles shall have door of approximate 500 mm length at the elevation of 500 mm from the Base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement. There shall also be suitable arrangement for the purpose of earthing. Material Octagonal Poles HT Steel Conforming to grade S355JO.Base Plate Fe 410 conforming to IS 226 / IS 2062Foundation Bolts EN.8 grade (Make - Bajaj, Lighting Technologies, GE or equivalent). The poles shall be hot dip galvanised as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 85 micron. The galvanizing shall be done in single dipping. The pole shall include two arms for fixing including supply of two nos 90 W LED street light luminaire with system efficacy greater than 120 lm/W. The luminaire must have a IP66 protection and IK07 protection, 4kV internal surge protection. The luminaire must have feature for auto high cut off @ 325 ± 15V & Auto Restart. The luminaire must be BIS certified and must have LM79 and LM80 reports from NABL accredited labs, including all accesories required for complete installation. The fixture shall be pressure die cast aluminium-alloy housing with corrosion resistance powder coating using nano technology with UV stabilized injection moulded PC cover for optimum light transmission (Make Lighting Technologies Adornis INT 90W 5700K LED pole mounted fixture or equivalent) (For nursing college and pediatric block)
od324977/2020_2021 : Supply of 40W well glass luminaire suitable for pendant mount application , pressure die cast aluminium alloy housing with corrosion resistance powder coating using nano technology, UV stabilized diffused cover for optomium light transmission, mounting using eyebolt mechanism, with IP66 protection including hangers and all accesroies as required for complete installtion<br>
od324978/2020_2021 : Supply of Suspended LED High Bay Luminaire with a nominal system lumen output of 10000 lumens & minimum system efficacy of 125 lm/W. Luminaire Wattage should not exceed 80W. Luminaire should have a color temperature of 6500K. Driver of the luminaire shall have PF >0.9. The luminaire housing should be made of die cast Aluminium with toughened glass front cover. Luminaire shall have 110 degree beam angle for better lighting distribution without any patches. Luminaire should be IP65 & IK07 rated. There should be in-built surge protection upto 2 KV. The driver shall comply to IEC 60598, IEC 62384 , IEC 61347-2-13, IEC 61547, EMI- CISPR15 standards. (Philips Make DuraLED High Bay BY325P LED100S-CW PSE GR FG WB or equivalent)<br>
RISING MAINS, BBT & TAP OFF BOXES
od75023/2020_2021 : Supply, installation, testing and commissioning of following capacity type tested as per IEC 61439 Part 6, pre-fabricated sandwich, Multi-layer insulated with each layer having Class F (155 Degree) PET (Poly ehteline terephthalate) insulation , compact, sandwitched indoor type (TPN With 100% Neutral ) rising mains from panels on ceiling/ wall/ structure, With high conductivity electrical grade aluminium (60% conductivity, 99.6% purity) in convenient sections suitable for 3 phase 4 wire 50Hz, 415V, AC supply. The bus bar shall be complete with expansion joints, fire barriers at each floor crossing, copper flexible end connections etc . The housing shall be constructed from 1.6mm (min) thick electro galvanised sheet steel enclosure, IP54 with epoxy coated. The busduct shall be complete with 4 nos aluminium busbar. Earthing with 2 runs of copper earth of size 25 x 6 mm copper strip shall be included in this scope of works on each side including clamping bracket, angle iron bracket, steel fastners, connecting to earthing system etc as required, including supports for bus bars. The rising mains shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of identical rising mains shall be furnished including all accesories required for complete installation.Rate shall be quoted for including all type of bends, complicated bends as per site condition, copper flexible conductors for termination, supports, hangers, flanged ends, adaptor box with terminal kits and all accesories required for complete installation. (Rsiing mains connection from panel to electrical shaft and vertical run of rising mains is considered in this item). Each raising main should be with 2 Tap-off points in each floor. Its should be possible to take upto 5 tap-off points from a standard 3 meter length bus duct from either sides. Plug-in Box interlock should be provided (It shouldn't be possible to plug-in or Withdraw plug-in box when MCCB in ON condition)<br>1600A Al TPN IP54 Rising Mains<br>
od75177/2020_2021 : Supply, installation, testing and commissioning of following capacity type tested as per IEC 61439 Part 6, pre-fabricated sandwich, Multi-layer insulated with each layer having Class F (155 Degree) PET (Poly ehteline terephthalate) insulation , compact, sandwitched indoor type (TPN With 100% Neutral ) bus trunking on wall / ceiling / structure, with high conductivity electrical grade aluminium (60% conductivity, 99.6% purity) conductor in convenient sections suitable for 3 phase 4 wire 50Hz, 415V, AC supply. The bus bar shall be complete with bends, expansion joints, fire barriers at wall/ceiling crossing, copper flexible end connections, elbows, adaptor boxes for termination in panels . The housing shall be constructed from 1.6mm (min) thick electro galvanised sheet steel enclosure, IP54 with epoxy coated. The busduct shall be complete with 4 nos aluminium busbar of same size. Earthing with 2 runs of copper earth of size 25 x 6 mm copper strip (Cu strip shall go inside LT panels and end termination boxes) on each side including clamping bracket, angle iron bracket, steel fastners, connecting to earthing system etc as required, including supports for bus bars. The bus duct shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of identical bus trunking shall be furnished. Rate shall be quoted for including all type of bends, complicated bends as per site condition, copper flexible conductors for termination, supports, hangers, flanged ends, adaptor box with terminal kits and all accesories required for complete installation. (Bus bar connection between transformers and panel, DG synch panel and Main panel and from other panel to panel connection is considered in this item)<br>2500A Al TPN IP54 Feeder busduct<br><br>
od75178/2020_2021 : Supply, installation, testing and commissioning of following capacity type tested as per IEC 61439 Part 6, pre-fabricated sandwich, Multi-layer insulated with each layer having Class F (155 Degree) PET (Poly ehteline terephthalate) insulation , compact, sandwitched indoor type (TPN With 100% Neutral ) bus trunking on wall / ceiling / structure, with high conductivity electrical grade aluminium (60% conductivity, 99.6% purity) conductor in convenient sections suitable for 3 phase 4 wire 50Hz, 415V, AC supply. The bus bar shall be complete with bends, expansion joints, fire barriers at wall/ceiling crossing, copper flexible end connections, elbows, adaptor boxes for termination in panels/transformer . The housing shall be constructed from 1.6mm (min) thick electro galvanised sheet steel enclosure, IP54 with epoxy coated. The busduct shall be complete with 4 nos aluminium busbar of same size. Earthing with 2 runs of copper earth of size 25 x 6 mm copper strip shall be included in this scope of works(Cu strip shall go inside LT panels and end termination boxes) on each side including clamping bracket, angle iron bracket, steel fastners, connecting to earthing system etc as required, including supports for bus bars. The bus duct shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of identical bus trunking shall be furnished. Rate shall be quoted for including all type of bends, complicated bends as per site condition, copper flexible conductors for termination, supports, hangers, flanged ends, adaptor box with terminal kits and all accesories required for complete installation. (Bus bar connection between transformers and panel, DG synch panel and Main panel and from other panel to panel connection is considered in this item)1600A Al TPN IP54 Feeder busduct<br>
od75179/2020_2021 : Supply, installation, testing and commissioning of following capacity type tested as per IEC 61439 Part 6, pre-fabricated sandwich, Multi-layer insulated with each layer having Class F (155 Degree) PET (Poly ehteline terephthalate) insulation , compact, sandwitched outdoor type (TPN With 100% Neutral ) bus trunking on wall / ceiling / structure, high conductivity electrical grade aluminium (60% conductivity, 99.6% purity) in convenient sections suitable for 3 phase 4 wire 50Hz, 415V, AC supply. The bus bar shall be complete with bends, expansion joints, fire barriers at wall/ceiling crossing, copper flexible end connections, elbows, adaptor boxes for termination in panels . The housing shall be constructed from 1.6mm (min) thick electro galvanised sheet steel enclosure, IP66 with epoxy coated. The busduct shall be complete with 4 nos aluminium busbar. Earthing with 2 runs of copper earth of size 25 x 6 mm copper strip (Cu strip shall go inside LT panels and end termination boxes of DG sets) on each side including clamping bracket, angle iron bracket, steel fastners, connecting to earthing system etc as required, including supports for bus bars. The bus duct shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of identical bus trunking shall be furnished. Rate shall be quoted for including all type of bends, copper flexible conductors for termination, supports, hangers, flanged ends, adaptor box with terminal kits and all accesories required for complete installation. The bus bar shall be supplied alongwith canopy for outdoor use with minimum 10 years life for the canopy without breakage or rusting or any damage.the same has to be certified by the manufacturer.<br>1600A Al TPN IP66 Feeder busduct<br>
od75180/2020_2021 : Supply, installation, testing and commissioning of following capacity type tested as per IEC 61439 Part 6, pre-fabricated sandwich, Multi-layer insulated with each layer having Class F (155 Degree) PET (Poly ehteline terephthalate) insulation , compact, sandwitched outdoor type (TPN With 100% Neutral ) bus trunking on wall / ceiling / structure, high conductivity electrical grade aluminium (60% conductivity, 99.6% purity) in convenient sections suitable for 3 phase 4 wire 50Hz, 415V, AC supply. The bus bar shall be complete with bends, expansion joints, fire barriers at wall/ceiling crossing, copper flexible end connections, elbows, adaptor boxes for termination in panels . The housing shall be constructed from 1.6mm (min) thick electro galvanised sheet steel enclosure, IP66 with epoxy coated. The busduct shall be complete with 4 nos aluminium busbar. Earthing with 2 runs of copper earth of size 25 x 6 mm copper strip shall be included in this scope of works(Cu strip shall go inside LT panels and end termination boxes of DG sets) on each side including clamping bracket, angle iron bracket, steel fastners, connecting to earthing system etc as required, including supports for bus bars. The bus duct shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of identical bus trunking shall be furnished. Rate shall be quoted for including all type of bends, supports, hangers, flanged ends, adaptor box with terminal kits and all accesories required for complete installation. The bus bar shall be supplied alongwith canopy for outdoor use with minimum 10 years life for the canopy without breakage or rusting or any damage and.the same has to be certified by the manufacturer.2500A Al TPN IP66 Feeder busduct<br>
od75181/2020_2021 : Supply, installation, testing and commissioning of following capacity type tested as per IEC 61439 Part 6, pre-fabricated sandwich, Multi-layer insulated with each layer having Class F (155 Degree) PET (Poly ehteline terephthalate) insulation , compact, sandwitched indoor type (TPN With 100% Neutral ) rising mains from panels on ceiling/ wall/ structure, With high conductivity electrical grade aluminium (60% conductivity, 99.6% purity) in convenient sections suitable for 3 phase 4 wire 50Hz, 415V, AC supply. The bus bar shall be complete with expansion joints, fire barriers at each floor crossing, copper flexible end connections etc . The housing shall be constructed from 1.6mm (min) thick electro galvanised sheet steel enclosure, IP54 with epoxy coated. The busduct shall be complete with 4 nos aluminium busbar. Earthing with 2 runs of copper earth of size 25 x 6 mm copper strip shall be included in this scope of works on each side including clamping bracket, angle iron bracket, steel fastners, connecting to earthing system etc as required, including supports for bus bars. The rising mains shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of identical rising mains shall be furnished including all accesories required for complete installation.Rate shall be quoted for including all type of bends, complicated bends as per site condition, copper flexible conductors for termination, supports, hangers, flanged ends, adaptor box with terminal kits and all accesories required for complete installation. (Rsiing mains connection from panel to electrical shaft and vertical run of rising mains is considered in this item). Each raising main should be with 2 Tap-off points in each floor. Its should be possible to take upto 5 tap-off points from a standard 3 meter length bus duct from either sides.Plug-in Box interlock should be provided (It shouldn't be possibel to plug-in or Withdraw plug-in box when MCCB in ON condition)<br>1250A Al TPN IP54 Rising Mains<br>
od75182/2020_2021 : Supply, installation, testing and commissioning of following capacity type tested as per IEC 61439 Part 6, pre-fabricated sandwich, Multi-layer insulated with each layer having Class F (155 Degree) PET (Poly ehteline terephthalate) insulation , compact, sandwitched indoor type (TPN With 100% Neutral ) rising mains from panels on ceiling/ wall/ structure, With high conductivity electrical grade aluminium (60% conductivity, 99.6% purity) in convenient sections suitable for 3 phase 4 wire 50Hz, 415V, AC supply. The bus bar shall be complete with expansion joints, fire barriers at each floor crossing, copper flexible end connections etc . The housing shall be constructed from 1.6mm (min) thick electro galvanised sheet steel enclosure, IP54 with epoxy coated. The busduct shall be complete with 4 nos aluminium busbar. Earthing with 2 runs of copper earth of size 25 x 6 mm copper strip shall be included in this scope of works on each side including clamping bracket, angle iron bracket, steel fastners, connecting to earthing system etc as required, including supports for bus bars. The rising mains shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of identical rising mains shall be furnished including all accesories required for complete installation.Rate shall be quoted for including all type of bends, complicated bends as per site condition, copper flexible conductors for termination, supports, hangers, flanged ends, adaptor box with terminal kits and all accesories required for complete installation. (Rsiing mains connection from panel to electrical shaft and vertical run of rising mains is considered in this item). Each raising main should be with 2 Tap-off points in each floor. Its should be possible to take upto 5 tap-off points from a standard 3 meter length bus duct from either sides.Plug-in Box interlock should be provided (It shouldn't be possibel to plug-in or Withdraw plug-in box when MCCB in ON condition)<br>1000A Al TPN IP54 Rising Mains<br>
od75183/2020_2021 : Supply, installation, testing and commissioning of following capacity type tested as per IEC 61439 Part 6, pre-fabricated sandwich, Multi-layer insulated with each layer having Class F (155 Degree) PET (Poly ehteline terephthalate) insulation , compact, sandwitched indoor type (TPN With 100% Neutral ) rising mains from panels on ceiling/ wall/ structure, With high conductivity electrical grade aluminium (60% conductivity, 99.6% purity) in convenient sections suitable for 3 phase 4 wire 50Hz, 415V, AC supply. The bus bar shall be complete with expansion joints, fire barriers at each floor crossing, copper flexible end connections etc . The housing shall be constructed from 1.6mm (min) thick electro galvanised sheet steel enclosure, IP54 with epoxy coated. The busduct shall be complete with 4 nos aluminium busbar. Earthing with 2 runs of copper earth of size 25 x 6 mm copper strip shall be included in this scope of works on each side including clamping bracket, angle iron bracket, steel fastners, connecting to earthing system etc as required, including supports for bus bars. The rising mains shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of identical rising mains shall be furnished including all accesories required for complete installation.Rate shall be quoted for including all type of bends, complicated bends as per site condition, copper flexible conductors for termination, supports, hangers, flanged ends, adaptor box with terminal kits and all accesories required for complete installation. (Rsiing mains connection from panel to electrical shaft and vertical run of rising mains is considered in this item). Each raising main should be with 2 Tap-off points in each floor. Its should be possible to take upto 5 tap-off points from a standard 3 meter length bus duct from either sides.Plug-in Box interlock should be provided (It shouldn't be possibel to plug-in or Withdraw plug-in box when MCCB in ON condition)800A Al TPN IP54 Rising Mains<br>
od75184/2020_2021 : Supply, installation, testing and commissioning of following capacity type tested as per IEC 61439 Part 6, pre-fabricated sandwich, Multi-layer insulated with each layer having Class F (155 Degree) PET (Poly ehteline terephthalate) insulation , compact, sandwitched indoor type (TPN With 100% Neutral ) rising mains from panels on ceiling/ wall/ structure, With high conductivity electrical grade aluminium (60% conductivity, 99.6% purity) in convenient sections suitable for 3 phase 4 wire 50Hz, 415V, AC supply. The bus bar shall be complete with expansion joints, fire barriers at each floor crossing, copper flexible end connections etc . The housing shall be constructed from 1.6mm (min) thick electro galvanised sheet steel enclosure, IP54 with epoxy coated. The busduct shall be complete with 4 nos aluminium busbar. Earthing with 2 runs of copper earth of size 25 x 6 mm copper strip shall be included in this scope of works on each side including clamping bracket, angle iron bracket, steel fastners, connecting to earthing system etc as required, including supports for bus bars. The rising mains shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of identical rising mains shall be furnished including all accesories required for complete installation.Rate shall be quoted for including all type of bends, complicated bends as per site condition, copper flexible conductors for termination, supports, hangers, flanged ends, adaptor box with terminal kits and all accesories required for complete installation. (Rsiing mains connection from panel to electrical shaft and vertical run of rising mains is considered in this item). Each raising main should be with 2 Tap-off points in each floor. Its should be possible to take upto 5 tap-off points from a standard 3 meter length bus duct from either sides.Plug-in Box interlock should be provided (It shouldn't be possibel to plug-in or Withdraw plug-in box when MCCB in ON condition)<br>630A Al TPN IP54 Rising Mains<br>
od75478/2020_2021 : Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity reducers for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The reducers shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of unit shall be furnished. including 2 runs of 25x6 mm size copper stirp run through the surface of reducers <br>800A to 630A<br>
od75481/2020_2021 : Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity reducers for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The reducers shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of unit shall be furnished. including 2 runs of 25x6 mm size copper stirp run through the surface of reducers<br>1000A to 630A<br>
od75482/2020_2021 : Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity reducers for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The reducers shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of unit shall be furnished. including 2 runs of 25x6 mm size copper stirp run through the surface of reducers1000A to 800A<br>
od75483/2020_2021 : Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity reducers for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The reducers shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of unit shall be furnished. including 2 runs of 25x6 mm size copper stirp run through the surface of reducers<br>1600A to 1000A<br>
od75642/2020_2021 : Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB for ratings from 63A to 250A and microprocessor based from 320A to 630A complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. It Should NOT be possible to plug-in or plug-out the boxes with MCCB in "ON" condition. MCCB RHOM door interlock also should be provided<br>63A 36kA FP MCCB in Plug - In Box<br>
od75643/2020_2021 : Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB for ratings from 63A to 250A and microprocessor based from 320A to 630A complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. It Should NOT be possible to plug-in or plug-out the boxes with MCCB in "ON" condition. MCCB RHOM door interlock also should be provided<br>100A 36kA FP MCCB in Plug - In Box<br>
od75644/2020_2021 : Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB for ratings from 63A to 250A and microprocessor based from 320A to 630A complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. It Should NOT be possible to plug-in or plug-out the boxes with MCCB in "ON" condition. MCCB RHOM door interlock also should be provided<br>160A 36kA FP MCCB in Plug - In Box<br>
od75645/2020_2021 : Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB for ratings from 63A to 250A and microprocessor based from 320A to 630A complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. It Should NOT be possible to plug-in or plug-out the boxes with MCCB in "ON" condition. MCCB RHOM door interlock also should be provided<br>250A 36kA FP MCCB in Plug - In Box<br>
od75646/2020_2021 : Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB for ratings from 63A to 250A and microprocessor based from 320A to 630A complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. It Should NOT be possible to plug-in or plug-out the boxes with MCCB in "ON" condition. MCCB RHOM door interlock also should be provided<br>200A 36kA FP MCCB in Plug - In Box<br>
od75648/2020_2021 : Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following rating T Joint for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The end feed unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of end feed unit shall be furnished. including 2 runs of 25x6 mm size copper stirp run through the surface <br>1250A T Joint<br>
od75649/2020_2021 : Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following rating End cover unit for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The end feed unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of end feed unit shall be furnished. including 2 runs of 25x6 mm size copper stirp run through the surface . <br>630A<br>
od75650/2020_2021 : Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following rating End cover unit for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The end feed unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of end feed unit shall be furnished. including 2 runs of 25x6 mm size copper stirp run through the surface <br>800A<br>
od75651/2020_2021 : Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity reducers for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The reducers shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of unit shall be furnished. including 2 runs of 25x6 mm size copper stirp run through the surface of reducers<br>1250A to 630A<br>
od75667/2020_2021 : Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity reducers for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The reducers shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of unit shall be furnished. including 2 runs of 25x6 mm size copper stirp run through the surface of reducers1250A to 1000A<br>
od75746/2020_2021 : Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following rating T Joint for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The end feed unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of end feed unit shall be furnished. including 2 runs of 25x6 mm size copper stirp run through the surface <br>1000A T Joint<br>
od209/2021_2022 : Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB for ratings from 63A to 250A complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. It Should NOT be possible to plug-in or plug-out the boxes with MCCB in "ON" condition. MCCB RHOM door interlock also should be provided<br>400A 36kA FP MCCB in Plug - In Box
QUICK RESPONSE FIRE SUPRESSION SYSTEM (FIRE SPOT PROTECTION FOR PANELS)
od75779/2020_2021 : "Supply, installation, testing and commisioning of Heat Sensor tube for automatic fire suppression system<br>made by special modified Polyamide (PA), Color Black, High grade HR quality, UV Stabilized, Inner diameter 4mm, Outer Diameter 6 MM. High Tech polyamide plastic Material with improved Burst Characteristic for maximum Safety and Reliability. Tube should be UV Protected for longer life with increased operating temperature which can withstand influence of other mediums, fluid etc. therefore is more durable compared to normal tubes, should be of robust detection and puncture characteristics to form a perfect discharge port for dispersing gas. The tube should be such that if a fire occurs and the tube burst, post fire, entire tubing should not be remove, only the burst area shall be cut out and connected in this area with new tube. Supply of tubing system shall include all connectors and ties and all accesories as required. For any supports or ties required for tubes, during panel manufacture itself, the same shall be fabricated alongwith the panel, so that no additional drilling or cuts or punches are made in the fabricated panel."<br>
od75780/2020_2021 : Supply, installation, testing and commisioning of self actuated fire spot protection for panels, quick response direct fire supression system which should work on class A, B & C fires and fires involving electrically charged devices, using HFC-236 Clean Agent, Fire Extinguisher. Clean Agent HFC 236fa DLP with Zero Ozone Depletion Potential. The extinguisher container shall be with valve assembly for connecting heat sensing tube and with pressure Switch to monitor Pressure in the tube, switch point 11 Bars and end of Line adapter for pressure gauge fitting for Automatic fire suppression tube used for fitting at the end of the tube for pressurizing and re pressurizing the tube. Maximum working pressure 25 Bars.. Each system shall consist of End of Line Plug for Automatic suppression tube used for fitting at the tube end to terminate the point. Maximum working pressure 25 bars. The system shall consist of pressure switch, alarm hooter for when a fire occurs, response indication panel including 24V DC adaptor including all accesories, batterys and power source as required, all connections and interconnections to be provided. The contractor should make sure that manufacturer should integrate with panel manufacturers during design and fabrication time so that holes and supports required for sensing tube and cylinder, hooter and all accesories can be fitted without any additional cutting, drilling or works at site after panels are fabricated. This has to be strictly followed and no exemptions shall be made. All requirements for mouting and installation of the supression system in panels shall be done during panel fabrication itself so as to get a finished product without additional cutting at site affecting panel integrity. For existing panels of the site, necessary holes and supports shall be made for integration of the system and the same shall be powder coated and repainted to restore panel integrity<br>The cylinders shall be manufactured using deep drawn process to minimize the welds and possible leakages, hydraulic pressure tested, helium leak detection tested. Containers are to be manufactured at ISO 9001 certified factory and as per EN Standard. Strong deep drawn cylinders powder coated to resist most corrosive enviorments. Containers should have IS 15683 and EN3 standards certifications.<br>Clean Agent used shall be HFC 236fa with zero ODP, environment friendly gase. Should have less than zero boiling point to be vapourised even in cold discharge cases. Providing larger coverage area. Gase are to approved by UL/FM. Agent should be non corrosive. with low boiling point to eliminate any chance of liquid accumalation in post fire disharge. Should not form acid at lung and blood interface.<br>Plug in connectors should meet in conjunction with the sensor tube, the requirements ISO16750-3: 2007. Meet the highest tightness requirements.<br>The clean agent used shall be LPCB approved. LPS 1666 issue-1.<br>The manufacturer should provide 1 year warranty for the entire system with minimum 4 visits during warranty period to check all installations, including valves etc and pressure of the cylinders complete as per standard. This shall be made sure by the contractor. The cylinders used including agent should have minimum life of 3 to 5 years.<br><br>4kg cylinder system with all accessories<br>
od75781/2020_2021 : Supply, installation, testing and commisioning of self actuated fire spot protection for panels, quick response direct fire supression system which should work on class A, B & C fires and fires involving electrically charged devices, using HFC-236 Clean Agent, Fire Extinguisher. Clean Agent HFC 236fa DLP with Zero Ozone Depletion Potential. The extinguisher container shall be with valve assembly for connecting heat sensing tube and with pressure Switch to monitor Pressure in the tube, switch point 11 Bars and end of Line adapter for pressure gauge fitting for Automatic fire suppression tube used for fitting at the end of the tube for pressurizing and re pressurizing the tube. Maximum working pressure 25 Bars.. Each system shall consist of End of Line Plug for Automatic suppression tube used for fitting at the tube end to terminate the point. Maximum working pressure 25 bars. The system shall consist of pressure switch, alarm hooter for when a fire occurs, response indication panel including 24V DC adaptor including all accesories, batterys and power source as required, all connections and interconnections to be provided. The contractor should make sure that manufacturer should integrate with panel manufacturers during design and fabrication time so that holes and supports required for sensing tube and cylinder, hooter and all accesories can be fitted without any additional cutting, drilling or works at site after panels are fabricated. This has to be strictly followed and no exemptions shall be made. All requirements for mouting and installation of the supression system in panels shall be done during panel fabrication itself so as to get a finished product without additional cutting at site affecting panel integrity. For existing panels of the site, necessary holes and supports shall be made for integration of the system and the same shall be powder coated and repainted to restore panel integrity<br>The cylinders shall be manufactured using deep drawn process to minimize the welds and possible leakages, hydraulic pressure tested, helium leak detection tested. Containers are to be manufactured at ISO 9001 certified factory and as per EN Standard. Strong deep drawn cylinders powder coated to resist most corrosive enviorments. Containers should have IS 15683 and EN3 standards certifications.<br>Clean Agent used shall be HFC 236fa with zero ODP, environment friendly gase. Should have less than zero boiling point to be vapourised even in cold discharge cases. Providing larger coverage area. Gase are to approved by UL/FM. Agent should be non corrosive. with low boiling point to eliminate any chance of liquid accumalation in post fire disharge. Should not form acid at lung and blood interface.<br>Plug in connectors should meet in conjunction with the sensor tube, the requirements ISO16750-3: 2007. Meet the highest tightness requirements.<br>The clean agent used shall be LPCB approved. LPS 1666 issue-1.<br>The manufacturer should provide 1 year warranty for the entire system with minimum 4 visits during warranty period to check all installations, including valves etc and pressure of the cylinders complete as per standard. This shall be made sure by the contractor. The cylinders used including agent should have minimum life of 3 to 5 years.<br>2kg cylinder system with all accessories<br>
od75782/2020_2021 : Supply, installation, testing and commisioning of self actuated fire spot protection for panels, quick response direct fire supression system which should work on class A, B & C fires and fires involving electrically charged devices, using HFC-236 Clean Agent, Fire Extinguisher. Clean Agent HFC 236fa DLP with Zero Ozone Depletion Potential. The extinguisher container shall be with valve assembly for connecting heat sensing tube and with pressure Switch to monitor Pressure in the tube, switch point 11 Bars and end of Line adapter for pressure gauge fitting for Automatic fire suppression tube used for fitting at the end of the tube for pressurizing and re pressurizing the tube. Maximum working pressure 25 Bars.. Each system shall consist of End of Line Plug for Automatic suppression tube used for fitting at the tube end to terminate the point. Maximum working pressure 25 bars. The system shall consist of pressure switch, alarm hooter for when a fire occurs, response indication panel including 24V DC adaptor including all accesories, batterys and power source as required, all connections and interconnections to be provided. The contractor should make sure that manufacturer should integrate with panel manufacturers during design and fabrication time so that holes and supports required for sensing tube and cylinder, hooter and all accesories can be fitted without any additional cutting, drilling or works at site after panels are fabricated. This has to be strictly followed and no exemptions shall be made. All requirements for mouting and installation of the supression system in panels shall be done during panel fabrication itself so as to get a finished product without additional cutting at site affecting panel integrity. For existing panels of the site, necessary holes and supports shall be made for integration of the system and the same shall be powder coated and repainted to restore panel integrity<br>The cylinders shall be manufactured using deep drawn process to minimize the welds and possible leakages, hydraulic pressure tested, helium leak detection tested. Containers are to be manufactured at ISO 9001 certified factory and as per EN Standard. Strong deep drawn cylinders powder coated to resist most corrosive enviorments. Containers should have IS 15683 and EN3 standards certifications.<br>Clean Agent used shall be HFC 236fa with zero ODP, environment friendly gase. Should have less than zero boiling point to be vapourised even in cold discharge cases. Providing larger coverage area. Gase are to approved by UL/FM. Agent should be non corrosive. with low boiling point to eliminate any chance of liquid accumalation in post fire disharge. Should not form acid at lung and blood interface.<br>Plug in connectors should meet in conjunction with the sensor tube, the requirements ISO16750-3: 2007. Meet the highest tightness requirements.<br>The clean agent used shall be LPCB approved. LPS 1666 issue-1.<br>The manufacturer should provide 1 year warranty for the entire system with minimum 4 visits during warranty period to check all installations, including valves etc and pressure of the cylinders complete as per standard. This shall be made sure by the contractor. The cylinders used including agent should have minimum life of 3 to 5 years.<br>6kg cylinder system with all accessories<br>
od75783/2020_2021 : Supply, installation, testing and commisioning of self actuated fire spot protection for panels, quick response direct fire supression system which should work on class A, B & C fires and fires involving electrically charged devices, using HFC-236 Clean Agent, Fire Extinguisher. Clean Agent HFC 236fa DLP with Zero Ozone Depletion Potential. The extinguisher container shall be with valve assembly for connecting heat sensing tube and with pressure Switch to monitor Pressure in the tube, switch point 11 Bars and end of Line adapter for pressure gauge fitting for Automatic fire suppression tube used for fitting at the end of the tube for pressurizing and re pressurizing the tube. Maximum working pressure 25 Bars.. Each system shall consist of End of Line Plug for Automatic suppression tube used for fitting at the tube end to terminate the point. Maximum working pressure 25 bars. The system shall consist of pressure switch, alarm hooter for when a fire occurs, response indication panel including 24V DC adaptor including all accesories, batterys and power source as required, all connections and interconnections to be provided. The contractor should make sure that manufacturer should integrate with panel manufacturers during design and fabrication time so that holes and supports required for sensing tube and cylinder, hooter and all accesories can be fitted without any additional cutting, drilling or works at site after panels are fabricated. This has to be strictly followed and no exemptions shall be made. All requirements for mouting and installation of the supression system in panels shall be done during panel fabrication itself so as to get a finished product without additional cutting at site affecting panel integrity. For existing panels of the site, necessary holes and supports shall be made for integration of the system and the same shall be powder coated and repainted to restore panel integrity<br>The cylinders shall be manufactured using deep drawn process to minimize the welds and possible leakages, hydraulic pressure tested, helium leak detection tested. Containers are to be manufactured at ISO 9001 certified factory and as per EN Standard. Strong deep drawn cylinders powder coated to resist most corrosive enviorments. Containers should have IS 15683 and EN3 standards certifications.<br>Clean Agent used shall be HFC 236fa with zero ODP, environment friendly gase. Should have less than zero boiling point to be vapourised even in cold discharge cases. Providing larger coverage area. Gase are to approved by UL/FM. Agent should be non corrosive. with low boiling point to eliminate any chance of liquid accumalation in post fire disharge. Should not form acid at lung and blood interface.<br>Plug in connectors should meet in conjunction with the sensor tube, the requirements ISO16750-3: 2007. Meet the highest tightness requirements.<br>The clean agent used shall be LPCB approved. LPS 1666 issue-1.<br>The manufacturer should provide 1 year warranty for the entire system with minimum 4 visits during warranty period to check all installations, including valves etc and pressure of the cylinders complete as per standard. This shall be made sure by the contractor. The cylinders used including agent should have minimum life of 3 to 5 years.<br>9kg cylinder system with all accessories<br>
od75832/2020_2021 : 4 x 300 kVA UPS in PRS Mode<br>Supply, installation, and commissioning of 4 nos x 300kVA (3 nos working & 1 no redundant) UPS Three phase in and out with PRS configuration. UPS shall be indoor type (IP20) with surge protection system with SMF battery of reputed approved make exide/quanta/panasonic), Input pf >0.99, input THDi <3 % without use of any external filters, external isolation transformers at output side for each UPS, double conversion technology with input voltage range 340-460 @ full load, 50Hz Three Phase, output 400V, 50Hz Three phase, MODBUS card for network monitoring with modbus/TCP/IP communication protocol, etc. It shall be 100% generator compatible, with Efficiency upto 96% in ECO mode and output power factor .9, and including all accessories etc as required.The system shall comply to EN 62040-1, IEC 61000-4, IEC 62040-2 and relevant IS & statutory standards. The acoustic noise at 1m of the system should be <73dB. The system shall be true online double - conversion DSP based UPS system and also UPS shall be with automatic bypass builtin. The system shall have IGBT rectifier and inverter. warranty minimum 2 years to be provided by manufacturer for UPS and batteries. Each UPS shall be with communicable port compatiable with Modbus communcation/TCP/IP communication protocol, for integration of UPS with SCADA. All valuable paramaters of the UPS including battery cablinet temperature details should be obtainable from the UPS for EMS integration. UPS shall be with parallel redundancy feature with expansion upto 8 units with emergency power off availiable local and remote with an event log of 3000 records minimum. Each UPS should have 15 min backup with seperate battery bank<br>"300kVA UPS with Isolation Transformer in output - 4 Nos, Battery Circuit Breakers as required, MODBUS CARD with modbus/TCP/IP communication protocol for integration with SCADA -4 Nos<br>Battery -12V sealed maintenance free batteries (SMF VRLA) with required number of batteries of required Ah as per manufacturer standard for providing 15 Minutes Back up for each UPS with Battery Accessories like battery rack, interconnecting cables, battery isolators etc. Battery calculation shall be provided before supply of the same."<br>All UPS shall be with necessary provision for integrating the UPS with IBMS & SCADA<br>Supply, Installation, testing & commisioning<br>
od315906/2020_2021 : 120 kVA Modular UPS<br>Supply, installation, and commissioning of 120kVA base frame UPS with 20kVA x 6 numbers modules Three phase in and out. UPS shall be indoor type (IP20) with surge protection system with SMF battery of reputed approved make exide/quanta/panasonic), Input pf >0.9, input THDi <3 % without use of any external filters, external isolation transformers at output side, double conversion technology, 50Hz Three Phase, MODBUS card for network monitoring with modbus/TCP/IP communication protocol, etc. It shall be 100% generator compatible, and including all accessories etc as required. The system shall be true online double - conversion DSP based UPS system and also UPS shall be with automatic bypass builtin. The system shall have IGBT rectifier and inverter. warranty minimum 2 years to be provided by manufacturer for UPS and batteries. UPS shall be with communicable port compatiable with Modbus communcation/TCP/IP communication protocol, for integration of UPS with SCADA. UPS should have 30 min backup with seperate battery bank. IGBT / PWM based True Online Double Conversion Technology, PFC, IGBT Inverter Fully Microprocessor Controlled, Inbuilt Redundancy & Capacity Paralleling, Inbuilt Static & Manual by pass - 0.99 PF, < 3% I thd, 94 % EFFICIENCY and Isolation Transformer.<br>"120kVA Modular UPS with Isolation Transformer in output - 1 Nos, Battery Circuit Breaker as required, MODBUS card with modbus/TCP/IP communication protocol for integration with SCADA -1 Nos<br>Battery -12V sealed maintenance free batteries (SMF VRLA) with required number of batteries of required Ah as per manufacturer standard for providing 30 Minutes Back up with Battery Accessories like battery rack, interconnecting cables, battery isolators etc. Battery calculation shall be provided before supply of the same."<br>All UPS shall be with necessary provision for integrating the UPS with IBMS & SCADA<br>Supply, Installation, testing & commisioning<br>
LIGHTNING & EARTHING PROTECTION
od75839/2020_2021 : LIGHTNING PROTECTION<br>"Supply and installation of 8mm solid aluminium round conductor: including Conductor holder for 8mm solid aluminium round conductor: For concrete building Terrace application: Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. With double conductor holder. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black. and all accesories as required for complete installation as instructed by engineer in charge.<br>"<br>
od75841/2020_2021 : LIGHTNING PROTECTION<br>"Supply and installation of 8mm solid aluminium round conductor with suitable conductor holder: For concrete building Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance including holder and all accesories as required for complete installation as instructed by engineer in charge.<br>a) Vertical run- Down conductor<br>
od75886/2020_2021 : LIGHTNING PROTECTION<br>Supply, installation, testing and commisioning of Lightning counter - To count no of lightning strike & it can record the date and time of the lightning incident.Tested from a laboratory acredited by UL, KEMA or VDE to be mounted inside enclosure including suitable weatherproof cabinet of sleek design as approved by client representative and all accesories required for complete installation <br>
od75887/2020_2021 : LIGHTNING PROTECTION<br>"Supply and installation of 8mm solid aluminium round conductor with suitable conductor holder: For concrete building Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance including holder and all accesories as required for complete installation as instructed by engineer in charge.<br>b) Horizontal run-Parapet application<br><br>
od75918/2020_2021 : LIGHTNING PROTECTION<br>"Supply, installation and tesing of 4 meter air terminal with accessories:Providing and fixing Air terminals as per IEC -62305 part-3 16mm rod tapered to 10 mm dia aluminium rod : Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) 101 VL 4000: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. System consist of Fang Fix with base and clamp on the top air terminal is erected. Fang fix clamp made of single sheet without weld cable bracket make punched and tested for lightning tested for 100 KA 10/350 as per IEC 62561. 2 nos of 16 KG stone of 365 mm diameter, high level of stability. Quick and easy mounting of interception rod using anchors. Concrete, frost-resistant, can be stacked. and all accesories as required for complete installation as instructed by engineer in charge.<br><br>"<br>
od76071/2020_2021 : LIGHTNING PROTECTION<br>Supply and fixing of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. Made of SS. Quick installation using hexagonal bolt M10X30. Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305) and all accesories as required for complete installation<br>
od76073/2020_2021 : LIGHTNING PROTECTION<br>Supply and Fixing earth fixed point: Made of Stainless Steel, grade 316L . Connection to earthing systems, air terminals and reinforcement. Contact plate: 79 mm diameter, made of rustproof stainless steel (V4A). Clamping bolt 10mm diameter, rustproof (V2A).To be tested for lightning current 100KA as per IEC 62561-1. Including plastic cover for simple installation. and all accesories as required for complete installation as instructed by engineer in charge.<br>
od76632/2020_2021 : LIGHTNING PROTECTION<br>Supply and installation of connector: -To connect air terminal with earth fixing point <br>
od76633/2020_2021 : LIGHTNING PROTECTION<br>Supply and installation of connector: For T cross and parallel connectors, Made of SS. Quick installation using hexagonal bolt M10X30. Conforms to the requirements according to DIN VDE 0185-305 (ISIEC 62305). To be tested for lightning current 100KA as per IEC 62561-1 <br>
od76634/2020_2021 : LIGHTNING PROTECTION<br>Supply and fixing of earth fixed point: Made of Stainless Steel, grade 316L . Connection to earthing systems, air terminals and reinforcement. Contact plate: 79 mm diameter, made of rustproof stainless steel (V4A). Clamping bolt 10mm diameter, rustproof (V2A).To be tested for lightning current 100KA as per IEC 62561-1. Including plastic cover for simple installation. and all accessories as required.<br>
od76635/2020_2021 : LIGHTNING PROTECTION<br>"Supply and laying 10mm dia solid copper coated round conductor with 250 micron copper coating . directly in concrete/screed working including providing clamps at every 2 m distance for support and connection as required, corrosion resistant. Should be tested and use exclusively for lightning protection earthing system bonding including SS material cross connectors and all accesories as required for complete installation as instructed by engineer in charge. (For vertical run inside columns and for mesh in concrete)<br>"<br>
od76636/2020_2021 : LIGHTNING PROTECTION<br>"Supply and laying 10mm dia solid copper coated round conductor with 250 micron copper coating . directly in ground as required, corrosion resistant. Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding including SS material cross connectors and all accesories as required for complete installation as instructed by engineer in charge. <br><br><br>
od76807/2020_2021 : EARTHING <br>Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant. <br>50x6 Cu strips tinned at the point of contact<br>
od76809/2020_2021 : LIGHTNING PROTECTION<br>Supply and fixing of Connector: For T cross and parallel connectors, Made of SS. Quick installation using hexagonal bolt M10X30. Conforms to the requirements according to DIN VDE 0185-305 (ISIEC 62305)(2nos/expansion piece ). To be tested for lightning current 100KA as per IEC 625611 and all accesories as required for complete installation<br>
od76952/2020_2021 : EARTHING <br>Supply, installation and tesing of 1200mmx1200mmx12mm CI plate electrode earth station conforming to IS:3043-1987 / NEC / IEE complete with brick masonry chamber, CI cover, CI frame, GI watering pipe of 50 mm dia with funnel having 20G GI wire mesh etc. The CI cover (heavy duty) frame/ chamber shall be of 450mm x 450mm size. CI manhole cover with frame shall be painted with bitumastic paint, identification of earthpit with yellow paint below the chamber cover, mixtures of charcoal & common salt around electrode including digging of pit up to permanent moisture level but not less than 3 metre depth and back filling. ( value of earth resistance should be less than 1 ohm )<br>
od77136/2020_2021 : EARTHING <br>Supply and laying the following sizes of strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant. <br>Copper wire No.10 SWG <br>
od77141/2020_2021 : EARTHING <br>Supply and laying the following sizes of strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant. <br>50x6mm Cu strips tinned at the point of contact<br>
od77188/2020_2021 : EARTHING <br>Providing coil/spring earthing using 2 runs of 8SWG, GI wire for street light pole etc. GI wire buried to a minimum depth of 1.5m, with excavation, refilling and connecting GI wire to pole using bolt and nut complete including all accessories required.(For bollards, post tops, street lighting poles etc)<br>
od78079/2020_2021 : EARTHING<br>Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant. <br>62x6 Cu strips tinned at the point of contact<br>
od78080/2020_2021 : EARTHING <br>Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant. <br> 25x3mm Cu strips tinned at the point of contact
od78081/2020_2021 : EARTHING <br>Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant. <br>32x6mm Cu strips tinned at the point of contact<br>
od78082/2020_2021 : EARTHING <br>Supply and laying the following sizes of strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant. <br>62x6 Cu strips tinned at the point of contact<br>
od78083/2020_2021 : EARTHING <br>Supply and laying the following sizes of strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant. <br>32x6mm Cu strips tinned at the point of contact<br>
od78084/2020_2021 : EARTHING <br>Supply and laying the following sizes of strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant. <br>25x3mm Cu strips tinned at the point of contact<br>
od78085/2020_2021 : EARTHING <br>Supply and laying the following sizes of strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant. <br>Copper wire No.8 SWG <br>
od78137/2020_2021 : LIGHTNING PROTECTION<br>Supply, installation and testing of maintenance free Earthing system as per IS 2309 ,IEC 62305 part3, IEC 60364, IEC 62561 part 2, IS 3043, UL 467 & UL 96 standards. Earthing System comprises of molecularly bonded copper of 99.9% purity on low carbon steel of 3m length (1m (219 20 CU) x 3 nos), having a diameter of 20mm with copper coating thickness of 250 microns with self-coupling bore and peg arrangement (without the need for external coupler) with fault current withstand capability of 20 KA rms value for 1 second and I peak of 50 KA. For obtaining desired length, the number of rods shall be increased and is provided with Universal Clamp (2730 20 VA) made of SS 304 for clamping the cable/flat conductor to the rod. Impact point (219 20 IP) on the bottom rod for easy insertion. Earth enhancing mineral compound (ECS PB 12.5) is used for improving the soil conductivity. Earth enhancing mineral compound shall be so designed and constructed that in normal use their performance is reliable and without danger to persons and the surroundings. The material shall be mineral inert to sub soil and shall not pollute the environment. It shall provide a stable environment in terms of physical and chemical properties and exhibit low resistivity. It shall not be corrosive to the earth electrode itself. The material should have a resistivity less than 0.2 Ohm meter. It should be free from hazardous substances The mineral compound is required to have minimum 12.5 Kg of the total composite. Polypropylene & Polyethylene (UFE)Earth electrode inspection chamber with heavy duty cover should be used to cover the Earth Rod. The dimension shall be 170mmx 170mmx 190mm with a weight bearing capacity of 5KN, including all accesories as required for complete installation as instructed by engineer in charge. (Minimum 2 earth pits shall be provided. No of earth pits shall be increased till overall earth resistance of the system is less than 10ohms as per site conditions and soil resistivity)
od85329/2020_2021 : Supply and Fixing Equipotential bonding rail for Lightning Arrestor applications(Test Joint). Equipotential bonding rail for equipotential bonding according to DIN VDE 0100-410/540 and lightning protection equipotetial bonding according to DIN VDE 0185-305. Base plate and cover hood from polystyrene. Colour: Black, UV resistant. Can be used outdoor also. Screw and crossbar made of VA. Capable of carring lightning current 100KA (10/350). Connection options: 7 x single or multi-core conductors to 25mm square or fine core conductors to 16mm square. 1 x round cable Rd 8-10. 1 x flat strip to FL 30 or round cable RD 8-10 including corrosion tapes and all accesories as required for complete installation as instructed by engineer in charge. To be connected to structural earthing mesh at a height of 2.5m from ground level for testing purpose
od315794/2020_2021 : Supply and installation of 8mm solid aluminium round conductor: For metal roof Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. Stainless steel base with Polyamide Conductor holder top: Bottom section with 8.5mm diameter slot With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance and all accesories as required for complete installation as instructed by engineer in charge.<br>
MISCELLANEOUS ITEMS
od78169/2020_2021 : INDUSTRIAL SOCKETS<br>Supplying, installation, testing & commisioning following surface mounting insulated plug and socket arrangement, power socket in independent position housed in suitable enclosure with high ingress protection (IP 67) with DIN rail for providing RCBO protection of suitable rating , with safe entry for cable and straight plugs with instant locking with screwless clamping, with direct connection with universal screws all terminals facing the same direction with large body size making wiring easy, maximum safety with elongated earth pin disconnected last on removal with direct mounting onto base and maximum cable grip with screwless clamp giving necessary connection as required including all acessories as required for complete installation and as directed by engineer in charge/consultant, and making good any damages made during installation.. <br>16A 2P+E<br>
od78170/2020_2021 : TERMINATION BOXES<br>Supply, installation, testing and commisioning of self extinguishing, weatherproof cabinets suitaible tfor outdoor application (IP 65, IK 09) with reversible door and cabinet with terminals for looping of cables and rail for fixing modular isolator along with 25A FP isolator including all connections and interconnections as required for outdoor application as instructed by engineer in charge.(For bollards, postops etc)<br>
od78171/2020_2021 : CABLE MANAGEMENT SYSTEM<br>Supply and fixing of 32 x 12.5 mm PVC Cable Management System with base and lid along with all accessories like external angle, internal angle, flat angle, end cap etc conforming to IEC 61084/ BS 476 & 4678 on surface as required and instructed by engineer in charge/consultant, including all accesories as required for complete installation. <br>32 x 12.5mm CMS <br>Detailed cost for 50metres<br>
od78172/2020_2021 : ELECTRICAL CAR CHARGING SOCKETS (NORMAL PLUG & SOCKET) <br>"Supply, installation, testing and commisioning of IP65 & IK10 protection, Plug & Interlock Socket Board-1 set, surface mounted type with following inbuilt accesories -<br>Incoming: 32A DP RCBO 300mA - 1 No.<br>Single phase Modular Meter DIN Rail Mounted, Direct Input up to 40A, Cl 1.0 Accuracy, with Electro Mechanical 7 Digit Display able to measure Active Energy up to 999999.9 kWh and with Pulse Output, RS485 module for integrating with SCADA software - 1 No.<br>Outgoing:<br>IP44 32A 3pin Plug & Interlock Socket - 1 No.<br>Including all connections and interconnections as required and as approved by client/consultant.<br>"<br>
od78173/2020_2021 : LIGHTING CONTROLS FOR CAR PARK AREA <br>Supplying, installation, testing & commissioning of Advance presence detection by Microwave technology. The sensor range is corner/ceiling mount 20 meter X 20 meter at a recommended mounting height of 3.5 meter. To control lighting load of 10 A, with features of delay time 5- 20 min, Passive photocell and Dual Sensitivity for Range. The sensors shall come withhandheld controllers for providing local user overide including all accesories as required (HONEYWELL MR1500P or equivalent)<br>
od78954/2020_2021 : PVC BOX<br>Supplying and fixing following size/modules, PVC open surface box / recess boxes to be placed on surface/recess for modular switches etc as required as instructed by engineer in charge<br>3 module<br>
od78955/2020_2021 : PVC BOX<br>Supplying and fixing following size/modules, PVC open surface box / recess boxes to be placed on surface/recess for modular switches etc as required as instructed by engineer in charge<br>1/2 module<br>
od78956/2020_2021 : RCBO<br>Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant..<br>63A 100mA FP RCBO<br>
od78957/2020_2021 : RCBO<br>Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant..<br>63A 100mA DP RCBO<br>
od78958/2020_2021 : RCBO<br>Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant..<br>40A 100mA DP RCBO<br>
od78959/2020_2021 : RCBO<br>Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant..<br>32A 30mA DP RCBO<br>
od78960/2020_2021 : RCBO<br>Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant..<br>25A 100mA DP RCBO<br>
od78961/2020_2021 : RCBO<br>Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant..<br>25A 30mA DP RCBO<br>
od78962/2020_2021 : MCCB:<br>Supply, fixing, testing and commisioning of following rating, breaking capacity and pole, type MCCB in existing Vertical Distribution Board with spredear links, terminal connections and all accesories as required making all necessary connections etc as required and instructed by engineer in charge/consultant.<br>63 Amp 16kA FP MCCB with Thermal-Magnetic Release<br>
od78963/2020_2021 : MCCB:<br>Supply, fixing, testing and commisioning of following rating, breaking capacity and pole, type MCCB in existing Vertical Distribution Board with spredear links, terminal connections and all accesories as required making all necessary connections etc as required and instructed by engineer in charge/consultant.<br>80 Amp 16kA FP MCCB with Thermal-Magnetic Release<br>
od78965/2020_2021 : MCCB:<br>Supply, fixing, testing and commisioning of following rating, breaking capacity and pole, type MCCB in existing Vertical Distribution Board with spredear links, terminal connections and all accesories as required making all necessary connections etc as required and instructed by engineer in charge/consultant.<br>125 Amp 16kA FP MCCB with Thermal-Magnetic Release<br>
od78966/2020_2021 : ISOLATOR FOR DB & VDB:<br>Supply, fixing, testing and commisioning of following rating and pole Isolator in existing Seven Segment Distribution Board, tier DBs and Vertical distribution board with spredear links, terminal connections and all accesories as required making all necessary connections etc as required and instructed by engineer in charge/consultant.<br>32A FP Isolator<br>
od78967/2020_2021 : ISOLATOR FOR DB & VDB:<br>Supply, fixing, testing and commisioning of following rating and pole Isolator in existing Seven Segment Distribution Board, tier DBs and Vertical distribution board with spredear links, terminal connections and all accesories as required making all necessary connections etc as required and instructed by engineer in charge/consultant.<br>25A FP Isolator<br>
od78968/2020_2021 : Wiring for Staircase Light Point<br>Wiring for stair case light points with 4 sq.mm FRLS PVC insulated copper conductor single core cable in and including surface / recessed medium class PVC conduit and all acessories required for complete installation etc , with 1 way modular 16A switch, modular plate, suitable GI box medium class PVC conduit and all acessories required etc and earthing the point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required and instructed by engineer in charge/consultant. (*Note - Staircase light point shall be controlled by a single switch located inside fire control room/security room/reception in ground floor as per latest fire norms. All staircase light points should be UPS powered. One switch will control all lights in one staircase)<br>Loop wiring for Light point<br>
od78969/2020_2021 : Wiring for Staircase Light Point<br>Wiring for stair case light points with 4 sq.mm FRLS PVC insulated copper conductor single core cable in and including surface / recessed medium class PVC conduit and all acessories required for complete installation etc , with 1 way modular 16A switch, modular plate, suitable GI box medium class PVC conduit and all acessories required etc and earthing the point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required and instructed by engineer in charge/consultant. (*Note - Staircase light point shall be controlled by a single switch located inside fire control room/security room/reception in ground floor as per latest fire norms. All staircase light points should be UPS powered. One switch will control all lights in one staircase)<br>One light point controlled by one way switch (at ground floor) (For each staircase)<br>
od78970/2020_2021 : Isolator With Enclosure<br>"Supply and fixing of following FP 415V, isolators in CRCA powder coated sheet steel enclosure with door interlock and padlock facility on surface with terminal shrouds on both sides and phase barriers included<br>Conforms to IEC 60947-3, IS/IEC 60947-3e complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation."<br>800A FP Isolator with enclosure<br>
od78971/2020_2021 : CHANGE OVER SWITCH<br>Supply, installation, testing and commisioning of following rating Change Over Switch conforming to IEC 60947-3, IS/IEC 60947 -3, with CRCA sheet powder coated enclosure, complete with terminals and all accessories etc as required and as instructed by engineer in charge and making good any damages made during installation.<br>32/40A, 415V, FP COS<br>
od78972/2020_2021 : CHANGE OVER SWITCH<br>Supply, installation, testing and commisioning of following rating Manual Change Over Switch conforming to IEC 60947-3, IS/IEC 60947 -3, with SS enclosure, padlock, complete with terminals and all accessories etc as required and as instructed by engineer in charge and making good any damages made during installation.<br>63A, 415V, FP COS<br>
od78973/2020_2021 : Isolator With Enclosure<br>Supply and fixing of FP CRCA sheet steel powder coated enclosure on surface/recess along with following Amps, 415V, DP/FP isolators confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>100A FP Isolator with enclosure<br>
od78974/2020_2021 : Isolator With Enclosure<br>Supply and fixing of FP CRCA sheet steel powder coated enclosure on surface/recess along with following Amps, 415V, DP/FP isolators confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>63A FP Isolator with enclosure<br>
od78975/2020_2021 : Isolator With Enclosure<br>Supply and fixing of FP CRCA sheet steel powder coated enclosure on surface/recess along with following Amps, 415V, DP/FP isolators confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>40A FP Isolator with enclosure<br>
od78976/2020_2021 : Isolator With Enclosure<br>Supply and fixing of FP CRCA sheet steel powder coated enclosure on surface/recess along with following Amps, 415V, DP/FP isolators confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>32A FP Isolator with enclosure<br>
od78977/2020_2021 : Isolator With Enclosure<br>Supply and fixing of FP CRCA sheet steel powder coated enclosure on surface/recess along with following Amps, 415V, DP/FP isolators confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>25A FP Isolator with enclosure<br>
od78978/2020_2021 : Isolator With Enclosure<br>Supply and fixing of FP CRCA sheet steel powder coated enclosure on surface/recess along with following Amps, 415V, DP/FP isolators confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>32A DP Isolator with enclosure<br>
od78979/2020_2021 : RCBO With Enclosure for stack parking Power Pack<br>Supplying, fixing, testing and commissioning following four pole 415 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in FP CRCA sheet steel powder coated enclosure on surface/recess complete with connections, etc. as required and instructed by engineer in charge/consultant..<br>32A 300mA FP RCBO<br>
od78980/2020_2021 : TPN SEVEN SEGMENT DB<br>Supplying,fixing, testing and commisioning following way, horizontal type three pole and neutral, sheet steel, MCB seven segment distribution board, conforming to IEC 61439-3, with seperate compartment for incomer, sub incomer & outgoings 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, insulated busbar & shrouded neutral bars, with provision for FP Isolator as incomer, DP RCBO as sub incomer and MCB outgoings. The DB shall have phase segmentation and seperation between incomer & outgoings, with wire set for interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)<br>12 way Seven Segment DB<br>
od78982/2020_2021 : TPN SEVEN SEGMENT DB<br>Supplying,fixing, testing and commisioning following way, horizontal type three pole and neutral, sheet steel, MCB seven segment distribution board, conforming to IEC 61439-3, with seperate compartment for incomer, sub incomer & outgoings 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, insulated busbar & shrouded neutral bars, with provision for FP Isolator as incomer, DP RCBO as sub incomer and MCB outgoings. The DB shall have phase segmentation and seperation between incomer & outgoings, with wire set for interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)<br>6 way Seven Segment DB<br>
od78983/2020_2021 : TPN SEVEN SEGMENT DB<br>Supplying,fixing, testing and commisioning following way, horizontal type three pole and neutral, sheet steel, MCB seven segment distribution board, conforming to IEC 61439-3, with seperate compartment for incomer, sub incomer & outgoings 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, insulated busbar & shrouded neutral bars, with provision for FP Isolator as incomer, DP RCBO as sub incomer and MCB outgoings. The DB shall have phase segmentation and seperation between incomer & outgoings, with wire set for interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)<br>4 way Seven Segment DB<br>
od78984/2020_2021 : Flexi/Row PPI DB<br>Supplying,fixing, testing and commisioning following way, vertical type three pole and neutral, sheet steel, MCB flexi row distribution board, conforming to IEC 61439-1&3, IS 8623-1, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, insulated busbar & shrouded neutral bars, with provision for FP Isolator as incomer, DP RCBO as sub incomer and MCB outgoings. The DB shall have phase segmentation and seperation between incomer & outgoings, with wire set for interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). DB shall be IP 43 rated double door with IK 09 protection fabricated with CRCA sheet steel, RAL 9003, powder coated with neutral bars with shrouds, earth bars, sticking saddles, cement spill protector, cable ties, blanking plates and circuit identification labels with provision for mounting modular devices as per requirement (But without MCB/RCCB/ Isolator). Incomer shall be 14 modules with provision for adding direct multifunction meter for EMS integration and surge arrestors. (DBs for OT & ICU)<br>4 Row 56 Module<br>
od78985/2020_2021 : TPN VDB<br>Supply, installation, testing and commisioning of vertical TPN DB conforming to IS 8623-1 &, IEC 61439-1 & 3, double door made of CRCA sheet steel, RAL 9003,powder coated enclosure, with insulated vertical phase bus-bars, neutral bars with shrouds, earth bars,sticking saddles, cement spill protector, color coded interconnecting wire set including all interconnections, with provision for MCCB as incomer and MCB's as outgoings,IP 43, IK09, including all connections, making good all damages made during installation as instructed by engineer in charge/consultant.<br>6 way VDB<br>
od78986/2020_2021 : MCB<br>Supply, installation, testing and commisioning of following rating TP C curve MCB, 10kA as per IS/IEC 60898-12002 in the existing MCB VDB including all connections and iterconnections as required and as instructed by engineer in charge/consultant. <br>63A TP MCB<br>
od78987/2020_2021 : MCB<br>Supply, installation, testing and commisioning of following rating TP C curve MCB, 10kA as per IS/IEC 60898-12002 in the existing MCB VDB including all connections and iterconnections as required and as instructed by engineer in charge/consultant. <br>40A TP MCB<br>
od78988/2020_2021 : SURGE ARRESTOR FOR DBs & VDBsSupply, installation testing & commisisoning of pluggable type surge arrester in vertical DBs, seven segmant DBs & flexi row DBS, Class B+C/ Class 1+2 as per IEC 61643 (IP 20) with potential free contact, thermal dis connector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number arrester Spark Gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E) . Lightning Impulse Current - 37.5 kA (10/350µ sec) for Line to Neutral & 25 kA(10/350µ sec) for Neutral to Earth,Nominal discharge current-30 kA (8/20µ sec) for Line to Neutral & 40 kA(8/20µ sec) for Neutral to Earth, max discharge current 150 kA (8/20µ sec) for Line to Neutral & 50 kA(8/20µ sec) for Neutral to Earth. Voltage protection level 1300V (L to N) & 1200V (N to E). Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E) DIN rail mounting type etc, DIN rail mounting type etc complete with back up MCB as required and as directed. and all accesories as required for complete installation of the same. Connection from Additional DIN bar which needs to be supplied and installed in DB for connecting surge arrestor to incomer shall be provided as reqired. All accesories and cut outs required for connecting DIN bar shall also be considered alongwith MCB isolator for protection of the same
od78989/2020_2021 : SURGE ARRESTOR FOR SMDBs / LOAD BANKS<br>Supply, installation testing & commisisoning of pluggable type surge arrester in bottom cabling module of SMDBs, Class B as per IEC 61643 (IP 20) with inbuilt common remote indication for defective arresters 3 nos of encapsulated spark gap and one number arrester encapsulated spark gap type to connect between Neutral and Earth of following ratings including base element & pluggable combination arrestor, 4-pole, with visual function display, for use in TN-S and TT networks. Completely pre-terminated and ready for connection, consisting of:, Type 1 (Class B) coordinated lightning current arrestor to DIN EN 61643-11. Coordinated N-PE spark gap, type 1 (Class B) to EN 61643-11 for use in TN-S and TT systems. Interface 0 to 1 according to lightning protection zone concept according to IEC 61312-1 and DIN VDE 0185-305.,with Arresting capacity 50 kA (10/350 μs) per pole (L-N), Arresting capacity 125 kA (10/350 μs) per pole (N-PE), Power consumption < 26 mW/pole, Protection level < 1.3 kV, Line follow current quenching 25 kA Ipeak, Incl. plug caps for identifying the connections, Encapsulated, non-extinguishing spark gap, Fixed in Junction box, with elevated transparent cover and plug-in seal with back up fuse as required and as directed. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. The scope shall include supply of arrestor with back up fuse of 160A rating HRC fuse unit (4 nos. ) in seperate holder mounted in the enclosure of the bottom module as backup for protection of the arrestor and all accesories as required for complete installation of the same, including all connections using Cu flexible cable and interconnections between fuse and arrestor and arrestor and incomer etc complete as required. (Cabling distance between arrestor and incomer shall be kept to minimum as per manufacturer standard)<br>Surge arrestor Class B<br>
od78990/2020_2021 : POP - UP BOX <br>Supply, Fixing, testing and commisisoning of 8(2x4) module Matt black finish pop up box with slim design for perfect integration into furniture equipped with 2 number 6A socket and 2 number CAT 6 data socket supplied alongwith installation kits for table tops and all accessories as required for complete installation including making good any damages made, as instructed by engineer in charge, providing connections etc as required. <br>
od78991/2020_2021 : POP - UP BOX <br>Supply, Fixing, testing and commisisoning of 8(2x4) module Matt black finish pop up box with slim design for perfect integration into furniture equipped with 2 number 6A socket and 1 number CAT 6 data socket & one number AV/HDMI socket supplied alongwith installation kits for table tops and all accessories as required for complete installation including making good any damages made, as instructed by engineer in charge, providing connections etc as required. <br>
od78992/2020_2021 : POP - UP BOX <br>Supply, Fixing, testing and commisisoning of 4 module Matt black finish pop up box with slim design for perfect integration into furniture equipped with one number 6A socket and one number CAT 6 data socket supplied alongwith installation kits for table tops and all accessories as required for complete installation including making good any damages made, as instructed by engineer in charge, providing connections etc as required.<br>
od78993/2020_2021 : INDUSTRIAL SOCKETS<br>Supplying, installation, testing & commisioning following surface mounting insulated plug and socket arrangement, power socket in independent position housed in suitable enclosure with high ingress protection (IP 67) with DIN rail for providing RCBO protection of suitable rating , with safe entry for cable and straight plugs with instant locking with screwless clamping, with direct connection with universal screws all terminals facing the same direction with large body size making wiring easy, maximum safety with elongated earth pin disconnected last on removal with direct mounting onto base and maximum cable grip with screwless clamp giving necessary connection as required including all acessories as required for complete installation and as directed by engineer in charge/consultant, and making good any damages made during installation.. <br>32A 3P+N+E<br>
od78994/2020_2021 : INDUSTRIAL SOCKETS<br>Supplying, installation, testing & commisioning following surface mounting insulated plug and socket arrangement, power socket in independent position housed in suitable enclosure with high ingress protection (IP 67) with DIN rail for providing RCBO protection of suitable rating , with safe entry for cable and straight plugs with instant locking with screwless clamping, with direct connection with universal screws all terminals facing the same direction with large body size making wiring easy, maximum safety with elongated earth pin disconnected last on removal with direct mounting onto base and maximum cable grip with screwless clamp giving necessary connection as required including all acessories as required for complete installation and as directed by engineer in charge/consultant, and making good any damages made during installation.. <br>16A 3P+N+E<br>
od79718/2020_2021 : MODULAR SWITCH & SOCKET<br>Supply and fixing of modular 25A power switch with indication placed in and including suitable size modular base and coverplate, mounted on suitable size modular GI/open PVC box, reccessed in the case of GI, fixing providing connections, testing and commisisoning and making good any damages made during installation as instructed by engineer in charge, including all accesories, connections and interconnections as required for complete installation.<br>
od79719/2020_2021 : MODULAR SWITCH & SOCKET<br>Supply and fixing of modular 25A power socket placed in and including suitable size modular base and coverplate, mounted on suitable size modular GI/open PVC box, reccessed in the case of GI, fixing providing connections, testing and commisisoning and making good any damages made during installation as instructed by engineer in charge, including all accesories, connections and interconnections as required for complete installation.<br>
od79720/2020_2021 : PVC BOX<br>Supplying and fixing following size/modules, PVC open surface box / recess boxes to be placed on surface/recess for modular switches etc as required as instructed by engineer in charge<br>8 module<br>
od79721/2020_2021 : PVC BOX<br>Supplying and fixing following size/modules, PVC open surface box / recess boxes to be placed on surface/recess for modular switches etc as required as instructed by engineer in charge<br>6 module<br>
od79722/2020_2021 : PVC BOX<br>Supplying and fixing following size/modules, PVC open surface box / recess boxes to be placed on surface/recess for modular switches etc as required as instructed by engineer in charge<br>4 module<br>
od79723/2020_2021 : RCBO<br>Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant..<br>32A 100mA DP RCBO<br>
od79724/2020_2021 : MCCB:<br>Supply, fixing, testing and commisioning of following rating, breaking capacity and pole, type MCCB in existing Vertical Distribution Board with spredear links, terminal connections and all accesories as required making all necessary connections etc as required and instructed by engineer in charge/consultant.<br>100 Amp 16kA FP MCCB with Thermal-Magnetic Release<br>
od79725/2020_2021 : TPN SEVEN SEGMENT DB<br>Supplying,fixing, testing and commisioning following way, horizontal type three pole and neutral, sheet steel, MCB seven segment distribution board, conforming to IEC 61439-3, with seperate compartment for incomer, sub incomer & outgoings 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, insulated busbar & shrouded neutral bars, with provision for FP Isolator as incomer, DP RCBO as sub incomer and MCB outgoings. The DB shall have phase segmentation and seperation between incomer & outgoings, with wire set for interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)<br>8 way Seven Segment DB<br>
od80044/2020_2021 : PVC FLEXIBLE CONDUIT<br>Supply and clamping the following size of corrugated pvc fiexible conduit with necessary locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required<br>32mm dia <br>
od80045/2020_2021 : PVC FLEXIBLE CONDUIT<br>Supply and clamping the following size of corrugated pvc fiexible conduit with necessary locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required<br>25mm dia <br>
od80046/2020_2021 : PVC FLEXIBLE CONDUIT<br>Supply and clamping the following size of corrugated pvc fiexible conduit with necessary locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required<br>20mm dia <br>
od80776/2020_2021 : CABLE TRAYS<br>"Supply and fixing of Hot dip galvanised Perforated Cable tray with suitable GI thread rod supports and brackets, profile rail and other accessories as required confirming to IEC-61537 and as required for complete installation. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The perforated tray shall be supplied with the standard length of 3 Mtr. All accesories required for complete installation shall be considered, hanging thread rod supports anchor bolted from ceiling , wall supports, connectors, etc shall be considereded alongwith the length of the tray. Cable tray routing shop drawing shall got approved from Consultant/Architect before execution at site. Supports shall be placed at minimum distance of 60cm as required. Fabrication works, including welding required for reducing of shape, size, providing bends and cross connections or offseting of cable trays as per site requirement shall also be considered in this scope. (Make OBO Betterman/Indiana). The trays shall be hanged from surface using GI threaded rods with base profile the same make as cable tray. Trays shall be welded, cut and fabricated as necessary into shapes and sizes as required as per site condition without any additional cost in a proffesional manner<br>"<br><br>100mm width x 60mm Height<br
od80777/2020_2021 : CABLE TRAYS<br>"Supply and fixing of Hot dip galvanised Perforated Cable tray with suitable GI thread rod supports and brackets, profile rail and other accessories as required confirming to IEC-61537 and as required for complete installation. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The perforated tray shall be supplied with the standard length of 3 Mtr. All accesories required for complete installation shall be considered, hanging thread rod supports anchor bolted from ceiling , wall supports, connectors, etc shall be considereded alongwith the length of the tray. Cable tray routing shop drawing shall got approved from Consultant/Architect before execution at site. Supports shall be placed at minimum distance of 60cm as required. Fabrication works, including welding required for reducing of shape, size, providing bends and cross connections or offseting of cable trays as per site requirement shall also be considered in this scope. (Make OBO Betterman/Indiana). The trays shall be hanged from surface using GI threaded rods with base profile the same make as cable tray. Trays shall be welded, cut and fabricated as necessary into shapes and sizes as required as per site condition without any additional cost in a proffesional manner<br>"<br><br>150mm width x 60mm Height
od80778/2020_2021 : CABLE TRAYS<br>"Supply and fixing of Hot dip galvanised Perforated Cable tray with suitable GI thread rod supports and brackets, profile rail and other accessories as required confirming to IEC-61537 and as required for complete installation. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The perforated tray shall be supplied with the standard length of 3 Mtr. All accesories required for complete installation shall be considered, hanging thread rod supports anchor bolted from ceiling , wall supports, connectors, etc shall be considereded alongwith the length of the tray. Cable tray routing shop drawing shall got approved from Consultant/Architect before execution at site. Supports shall be placed at minimum distance of 60cm as required. Fabrication works, including welding required for reducing of shape, size, providing bends and cross connections or offseting of cable trays as per site requirement shall also be considered in this scope. (Make OBO Betterman/Indiana). The trays shall be hanged from surface using GI threaded rods with base profile the same make as cable tray. Trays shall be welded, cut and fabricated as necessary into shapes and sizes as required as per site condition without any additional cost in a proffesional manner<br>"<br><br>200mm width x 60mm Height
od80779/2020_2021 : CABLE TRAYS<br>"Supply and fixing of Hot dip galvanised Perforated Cable tray with suitable GI thread rod supports and brackets, profile rail and other accessories as required confirming to IEC-61537 and as required for complete installation. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The perforated tray shall be supplied with the standard length of 3 Mtr. All accesories required for complete installation shall be considered, hanging thread rod supports anchor bolted from ceiling , wall supports, connectors, etc shall be considereded alongwith the length of the tray. Cable tray routing shop drawing shall got approved from Consultant/Architect before execution at site. Supports shall be placed at minimum distance of 60cm as required. Fabrication works, including welding required for reducing of shape, size, providing bends and cross connections or offseting of cable trays as per site requirement shall also be considered in this scope. (Make OBO Betterman/Indiana). The trays shall be hanged from surface using GI threaded rods with base profile the same make as cable tray. Trays shall be welded, cut and fabricated as necessary into shapes and sizes as required as per site condition without any additional cost in a proffesional manner<br>"<br><br>400mm width x 60mm Height
od80780/2020_2021 : CABLE TRAYS<br>"Supply and fixing of Hot dip galvanised Perforated Cable tray with suitable GI thread rod supports and brackets, profile rail and other accessories as required confirming to IEC-61537 and as required for complete installation. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The perforated tray shall be supplied with the standard length of 3 Mtr. All accesories required for complete installation shall be considered, hanging thread rod supports anchor bolted from ceiling , wall supports, connectors, etc shall be considereded alongwith the length of the tray. Cable tray routing shop drawing shall got approved from Consultant/Architect before execution at site. Supports shall be placed at minimum distance of 60cm as required. Fabrication works, including welding required for reducing of shape, size, providing bends and cross connections or offseting of cable trays as per site requirement shall also be considered in this scope. (Make OBO Betterman/Indiana). The trays shall be hanged from surface using GI threaded rods with base profile the same make as cable tray. Trays shall be welded, cut and fabricated as necessary into shapes and sizes as required as per site condition without any additional cost in a proffesional manner<br>"<br><br>500mm width x 60mm Height
od80781/2020_2021 : CABLE TRAYS<br>"Supply and fixing of Hot dip galvanised Perforated Cable tray with suitable GI thread rod supports and brackets, profile rail and other accessories as required confirming to IEC-61537 and as required for complete installation. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The perforated tray shall be supplied with the standard length of 3 Mtr. All accesories required for complete installation shall be considered, hanging thread rod supports anchor bolted from ceiling , wall supports, connectors, etc shall be considereded alongwith the length of the tray. Cable tray routing shop drawing shall got approved from Consultant/Architect before execution at site. Supports shall be placed at minimum distance of 60cm as required. Fabrication works, including welding required for reducing of shape, size, providing bends and cross connections or offseting of cable trays as per site requirement shall also be considered in this scope. (Make OBO Betterman/Indiana). The trays shall be hanged from surface using GI threaded rods with base profile the same make as cable tray. Trays shall be welded, cut and fabricated as necessary into shapes and sizes as required as per site condition without any additional cost in a proffesional manner<br>"<br>300mm width x 60mm Height
od324833/2020_2021 : Supply, installation, testing and commisioning of following rating Manual Change Over Switch conforming to IEC 60947-3, IS/IEC 60947 -3, with SS enclosure, padlock, complete with terminals and all accessories etc as required and as instructed by engineer in charge and making good any damages made during installation.<br>100A, 415V, FP COS<br>
od333019/2020_2021 : "Supply and fixing of following FP 415V, isolators in CRCA powder coated sheet steel enclosure with door interlock and padlock facility on surface with terminal shrouds on both sides and phase barriers included<br>Conforms to IEC 60947-3, IS/IEC 60947-3e complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation."<br>200A FP Isolator with enclosure<br>
od207/2021_2022 : "Supply and fixing of following FP 415V, isolators in CRCA powder coated sheet steel enclosure with door interlock and padlock facility on surface with terminal shrouds on both sides and phase barriers included<br>Conforms to IEC 60947-3, IS/IEC 60947-3e complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation."<br>125A FP Isolator with enclosure<br>
CABLES & END TERMINATION
od79729/2020_2021 : Supply, laying, clamping, testing & commisioning of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded conductor, XLPE insulated, PVC inner sheathed1.1kV grade strictly conforming to IS:1554 (Part-I) 1964 of the following sizes in cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages colour washing etc as required. and instructed by engineer at site/consultant.<br>1cx185sq.mm Copper Flexible Cable<br>
od79731/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>2cx2.5sq.mm Cu Control Cable<br>
od79732/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>12cx2.5 sq.mm Cu control Cable<br>
od79734/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>2cx6sq.mm Al Cable<br>
od79735/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>2cx10sq.mm Al Cable<br>
od79736/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4cx4sq.mm 2XFY Copper Cable<br>
od79737/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4cx4sq.mm Al Cable<br>
od79738/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4cx6sq.mm 2XFY Copper Cable<br>
od79739/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4cx6sq.mm Al Cable<br>
od79740/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3cx10sq.mm Al Cable<br>
od79741/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4cx10sq.mm 2XFY Copper Cable<br>
od79742/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4cx10sq.mm Al Cable<br>
od79743/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3cx16sq.mm Al Cable<br>
od79744/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4cx16sq.mm Al Cable<br>
od79745/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4cx25sq.mm Al Cable<br>
od79746/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3cx35sq.mm Al Cable<br>
od79747/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx35sq.mm Al Cable<br>
od79748/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4cx35sq.mm Al Cable<br>
od79749/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx50sq.mm Al Cable<br>
od79750/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4cx50sq.mm Al Cable<br>
od79751/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx70sq.mm Al Cable<br>
od79752/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx95sq.mm Al Cable<br>
od79753/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4cx95sq.mm Al Cable<br>
od79755/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx150sq.mm Al Cable<br>
od79756/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4cx150sq.mm Al Cable<br>
od79757/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx185sq.mm Al Cable<br>
od79758/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4cx185sq.mm Al Cable<br>
od79761/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx300sq.mm Al Cable<br>
od79762/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4cx300sq.mm Al Cable<br>
od79763/2020_2021 : LT CABLE SUPPLY<br>Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx400sq.mm Al Cable<br>
od79978/2020_2021 : END TERMINATION<br>Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured.<br>5Cx1.5 sq.mm Cu Control Cable<br>
od79980/2020_2021 : END TERMINATION<br>Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured.<br>2Cx2.5 sq.mm Cu Control Cable<br>
od79981/2020_2021 : END TERMINATION<br>Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured.<br>12Cx2.5 sq.mm Cu control Cable<br>
od79983/2020_2021 : END TERMINATION<br>Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured.<br>4Cx4sq.mm Al Cable<br>
od79984/2020_2021 : END TERMINATION<br>Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured.<br>4Cx6sq.mm Al Cable<br>
od79985/2020_2021 : END TERMINATION<br>Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured.<br>4Cx95sq.mm Al Cable<br>
od79986/2020_2021 : END TERMINATION<br>Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured.<br>4Cx150sq.mm Al Cable<br>
od79987/2020_2021 : END TERMINATION<br>Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured.<br>4Cx185sq.mm Al Cable<br>
od79989/2020_2021 : END TERMINATION<br>Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured.<br>4Cx300sq.mm Al Cable<br>
od79990/2020_2021 : END TERMINATION<br>Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured.<br>4C x 10sqmm X2FY Cable (Copper Cable)<br>
od79991/2020_2021 : END TERMINATION<br>Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured.<br>4C x 6sqmm X2FY Cable (Copper Cable)<br>
od79992/2020_2021 : END TERMINATION<br>Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured.<br>4C x 4sqmm X2FY Cable (Copper Cable)<br>
od80212/2020_2021 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.<br>185 sq.mm<br>
od324805/2020_2021 : Supply, laying, clamping, testing & commisioning of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded conductor, XLPE insulated, PVC inner sheathed1.1kV grade strictly conforming to IS:1554 (Part-I) 1964 of the following sizes in cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages colour washing etc as required. and instructed by engineer at site/consultant.<br>1cx400sq.mm Copper Flexible Cable
od324806/2020_2021 : Supply, laying, clamping, testing & commisioning of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded conductor, XLPE insulated, PVC inner sheathed1.1kV grade strictly conforming to IS:1554 (Part-I) 1964 of the following sizes in cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages colour washing etc as required. and instructed by engineer at site/consultant.<br>1cx120sq.mm Copper Flexible Cable<br>
od324807/2020_2021 : Supply, laying, clamping, testing & commisioning of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded conductor, XLPE insulated, PVC inner sheathed1.1kV grade strictly conforming to IS:1554 (Part-I) 1964 of the following sizes in cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages colour washing etc as required. and instructed by engineer at site/consultant.<br>1cx35sq.mm Copper Flexible Cable<br>
od324808/2020_2021 : Supply, laying, clamping, testing & commisioning of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded conductor, XLPE insulated, PVC inner sheathed1.1kV grade strictly conforming to IS:1554 (Part-I) 1964 of the following sizes in cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages colour washing etc as required. and instructed by engineer at site/consultant.<br>1cx6sq.mm Copper Flexible Cable
od324875/2020_2021 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.<br>6 sq.mm<br>
od324876/2020_2021 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.<br>35 sq.mm<br>
od324877/2020_2021 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.<br>120 sq.mm
od324878/2020_2021 : <br>Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.<br>400 sq.mm<br>
od332955/2020_2021 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, arSupply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>moured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>5x1.5sq.mm Cu Control Cable<br>
LT PANELS
od80889/2020_2021 : FIRE LIFT PANEL (TYPICAL 1 - 3)<br>Fabrication, supply, installation, testing & commissioning of cubical type, dust and vermin proof, wall mounted, front operated MV panel board, sheet steel enclosure with door sheet steel all round foamed-in PU seal with dipcoat primed, powder coated on the outside, textured paint with zinc-plated mounting plate. The colour shall be RAL 7035 with IP 66 protection, NEMA 4 protection category, IK08 impact resistance with hinged doors, all round solid construction, gland plate, mounting plate, Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. <br>Incomers<br>Incomer - 80A TPN Isolator - 2 no<br>80A 415V, 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required.<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Outgoings<br>63A 100mA FP RCBO - 2 nos.<br>25A 30mA DP RCBO - 1 no<br>6A SP MCB - 4 nos.<br><br>Potential free contacts shall be made availiable as required for integrating electrical system with IBMS. Required provisions shall be made availiable for the same as per IO summary of IBMS.<br>Supply, Installation, testing and commisioning <br>
od80891/2020_2021 : PASSENGER LIFT PANEL 1<br>Fabrication, supply, installation, testing & commissioning of cubical type, dust and vermin proof, wall mounted, front operated MV panel board, sheet steel enclosure with door sheet steel all round foamed-in PU seal with dipcoat primed, powder coated on the outside, textured paint with zinc-plated mounting plate. The colour shall be RAL 7035 with IP 66 protection, NEMA 4 protection category, IK08 impact resistance with hinged doors, all round solid construction, gland plate, mounting plate, Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. <br>Incomers<br>Incomer - 100A TPN Isolator - 1 no<br>100A 415V, 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required.<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Outgoings<br>63A 100mA FP RCBO - 3 nos.<br>25A 30mA FP RCBO - 1 no<br>6A SP MCB - 8 nos.<br>Potential free contacts shall be made availiable as required for integrating electrical system with IBMS. Required provisions shall be made availiable for the same as per IO summary of IBMS.<br>Supply, Installation, testing and commisioning <br>
od80892/2020_2021 : PASSENGER LIFT PANEL 2,3 & 4 & SERVICE LIFT PANEL 1, 2 & 3<br>Fabrication, supply, installation, testing & commissioning of cubical type, dust and vermin proof,, wal mounted, front operated MV panel board, sheet steel enclosure with door sheet steel all round foamed-in PU seal with dipcoat primed, powder coated on the outside, textured paint with zinc-plated mounting plate. The colour shall be RAL 7035 with IP 66 protection, NEMA 4 protection category, IK08 impact resistance with hinged doors, all round solid construction, gland plate, mounting plate, Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. <br>Incomers<br>Incomer - 80A TPN Isolator - 1 no<br>80A 415V, 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required.<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Outgoings<br>63A 100mA FP RCBO - 2 nos.<br>25A 30mA DP RCBO - 1 no<br>6A SP MCB - 4 nos.<br>Potential free contacts shall be made availiable as required for integrating electrical system with IBMS. Required provisions shall be made availiable for the same as per IO summary of IBMS.<br>Supply, Installation, testing and commisioning <br>
od80893/2020_2021 : GOODS LIFT PANEL <br>Fabrication, supply, installation, testing & commissioning of cubical type, dust and vermin proof,wall mounted, front operated MV panel board, sheet steel enclosure with door sheet steel all round foamed-in PU seal with dipcoat primed, powder coated on the outside, textured paint with zinc-plated mounting plate. The colour shall be RAL 7035 with IP 66 protection, NEMA 4 protection category, IK08 impact resistance with hinged doors, all round solid construction, gland plate, mounting plate, Doors are to be fitted with conceal hinge with name plate, danger notice board, including all switchgears and components as shown in the schematic drawing. All opening parts of the panel shall be sealable. <br>Incomers<br>Incomer - 63A TPN Isolator - 1 no<br>63A 415V, 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required.<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Outgoings<br>40A 100mA FP RCBO - 2 nos.<br>25A 30mA DP RCBO - 1 no<br>6A SP MCB - 4 nos.<br>Potential free contacts shall be made availiable as required for integrating electrical system with IBMS. Required provisions shall be made availiable for the same as per IO summary of IBMS.<br>Supply, Installation, testing and commisioning <br>
HT PART
od80535/2020_2021 : HT CABLE LAYING<br>Laying of following 11kV (E) grade XLPE insulated PVC sheathed compact circular armoured aluminium conductor HT power cable, insulation screened with extruded semi conducting compound in separate existing cable tray using factory made clamps and the spacing between clamps will not exceed 60cm.<br>Above 120 sq. mm and upto 400 sq. mm<br>
od80536/2020_2021 : HT CABLE SUPPLY<br>Supply of following 11kV (E) grade XLPE insulated PVC sheathed compact circular armoured aluminium conductor HT power cable, insulation screened with extruded semi conducting compound in combination with copper tape suitable for 11kV earthed system confirming to relavent standard. <br>3cx240sq.mm XLPE Cable<br>
od80537/2020_2021 : TRANSFORMERS<br>1600 kVA 11kV/433V Cast Resin (Dry type) Laser Scribed K4 rated Transformer<br>Supply, installation, testing & commissioning of 1600kVA 11kV/433V indoor cast resin dry type laser scribed core transformer (copper double wound) with OLTC having a continuous rating for 11kV / 433V 3 phase 50 Hz. Vector group Dyn 11 with tapping +5% to -15% in steps of 1.25% changeable by OLTC, AVR & RTCC, including separate winding temperature indicator for each phase and core in the Transformer. Transformer should have cable end box on HV side suitable for 3Cx240 sq.mm XLPE cable and suitable end box on LV side for connecting 2500A Al BBT, with all accessories, complete as required as per State electricity board, ECBC, IE rules specifications. The transformer shall confirm to IS 2067/77, 11171/85 with latest amendment etc complete. Transformer shall be CPRI tested and test reports to be furnished as per IS 11171/85(Reaffirmed 2016). Transformer and all accesories included shall be supplied with minimum two years warranty against manufacturing /defects/ damages by manufacturer. No excemption in any components will be accepted for warranty exemptions. Insulation class of transformer shall be class H with maximum winding temperature and hot spot temperature as per IS. Tolerances, voltage regulation and all losses, impedance and other parameter values shall be as per IS tolerance and test certificates of the same to be provided. Cable entry & bus bar outgoing for transformer shall be top entry. Colling shall be ANAF. Transformer shall be rated K-4 (k factor for harmonics effect heating reduction design class). Harmonics mitigating suppresors shall also be considered in the transformer. K-factor of the transformer shall be inscribed in the nameplate of the transformer. Impulse voltage withstand at HV side and power frequency withstand voltage at HV side and LV side shall be as per standards and test certificates for the same shall be furnished. Transformer enclosure shall be powder coated after 7 tank treatment. All routine tests as per standards to be provided before dispatch of the transformers alongwith which load testing shall be conducted for minimum 4 hours. All test results should be found satisfactory by the Client representative before dispatch. Push button for emergency OFF shall be placed outside in seperate enclosure, painted in red covered by glass.<br>
od80538/2020_2021 : HT PANEL BOARD<br>Supply, installation, testing and commissioning of dust and vermin proof floor mounted free standing cubicle type, 11kV, extensible panel board made out of metal clad fully compartmentalised complete with hinged and earthed front doors interlocked with the earth switch, comprising of one number of 630A VCB as incomer with three numbers of 630A VCB as outgoings as per the specification details below. Panel shall be factory fitted type with type testing certificates as per IEC 62271 Part 100(for VCB) & Part 200(for enclosure). Panel shall be supplied with minimum two years warranty against manufacturing / maintenance defects/ damages by manufacturer. No excemption in any components will be accepted for warranty exemptions. All CTs & PTs shall be type tested as per standards and certificates shall be produced before supply of the panel test shall include but not limited to polarity test, high voltage power-frequency one minute withstand test, induced over voltage test, partial discharge measurement, accuracy test, intertum insultation test, dimension check, ratio and phase angle error test etc. Insulation resistance test and fuctional testes of panel and VCB shall be produced. Fuctuional tests shall include but not be limited to mechanical operation test for opening and closing under no load condition, master trip relay and auxilary relays, over current and earth fault relay test, breaker rack IN and Rack OUT , MFM, voltmeter, ammeter and all other meters programmed and checked, motor charging etc. Panel shall include all relays and tripping mechanisms and accesories as required as per KSEI standards. Panel shall have cable entry on top side for both incoming and outgoing cables. HT panel board shall be manufactured with provision for installing HT TOD bidirection meters in incomer side as per schematic layout with necessary CTs and all accesories as required. All VCBs shall be with open protocol IEC61850 communication protocol for communicating with SCADA software<br>Incoming:<br>1no:-11kV 630A, 3phase 50Hz, 350MVA, breaking capacity vacuum circuit breaker dust and vermin proof totally enclosed in sheet steel housing, fully inter locked, horizontal draw out and horizontal isolation, indoor truck type with trip free spring closing mechanism with mechanical ON/OFF indicators, earthing terminals automatic safety shutters, complete with auxiliary contacts, resin cast CTs of suitable ratio and accuracy class for protection & metering(Class0.2 S) .<br>Draw out type resin cast P.T with inbuilt fuses of ratio 11kV/110V, CL :0.2S must be provided. Bus bar compartment shall have suitable capacity non-hygroscopic and high dieletric strength SMC/FRP busbar supports with electrolytic aluminium busbars covered with suitable sleeves. WIth breaker control switch, switch with plug point, strip heater, thermostat for space heater, cubicle lamp with switch, seal of bushings including all connections and interconnections. Metering compartments for mounting digital meter and numerical relays for feeder protection, shunt/series trip coil, under voltage release, indication lamps, spring charge, trip circuit healthy, alram, RYM indication cable entry boxes, including all interconnections, providing fire/heat resistant coatings for busbar & CB truck enclosures and powder coating complete panel as per IS-2516 & IS 3427 with latest amendments complete as required with manually charged spring closing system. It shall also be provided with Instantenous IDMT relay 2 O/C + 1 E/F relay CDAG-51 or Equivalent with high Set, Master Trip Relay. Provision shall be provided for fixing TOD meter including connections<br>Out goings :<br>3 nos:-11kV 630A, 3phase 50Hz, 350MVA, breaking capacity vacuum circuit breaker dust and vermin proof totally enclosed in sheet steel housing, fully inter locked, horizontal draw out and horizontal isolation, indoor truck type with trip free spring closing mechanism with mechanical ON/OFF indicators, earthing terminals automatic safety shutters, complete with auxiliary contacts<br>Bus bar compartment shall have suitable capacity non-hygroscopic and high dieletric strength SMC/FRP busbar supports with electrolytic aluminium busbars covered with suitable sleeves. WIth breaker control switch, switch with plug point, strip heater, thermostat for space heater, cubicle lamp with switch, seal of bushings including all connections and interconnections. Metering compartments for mounting digital meter and numerical relays for feeder protection, shunt/series trip coil, under voltage release, indication lamps, spring charge, trip circuit healthy, alram, RYM indication cable entry boxes, including all interconnections, providing fire/heat resistant coatings for busbar & CB truck enclosures andpowder coating complete panel as per IS-2516 & IS 3427 with latest amendments complete as required with manually charged spring closing system. It shall also be provided with Instantenous IDMT relay 2 O/C + 1 E/F relay CDAG-51 or Equivalent with high Set, Master Trip Relay. <br>The panel shall include auxillary DC power supply unit, 24V, with required Ah capacity battery power pack including all accesories required for complete backup of all indicators, mechanisam and operating system in the panel with stationary type, high discharge perfomance,Valve Regulated Lead Acid (VRLA) sealed maintenance free battery, battery charger including all other accessories like battery rack, interconnecting cables etc as required The power pack and accesories shall be placed in the panel itself.<br>
od80548/2020_2021 : HT CABLE SUPPLY<br>Supply of following 11kV (E) grade XLPE insulated PVC sheathed compact circular armoured aluminium conductor HT power cable, insulation screened with extruded semi conducting compound in combination with copper tape suitable for 11kV earthed system confirming to relavent standard. <br>3cx300sq.mm XLPE Cable<br>
od324823/2020_2021 : BIDIRECTIONAL HT TOD NET METER<br>Supply, Installation, testing & commissioning of 3 phase 4 wire according to IS14697-1999, CBIP-325, IS 159595A, class: 0.2S, TOD meter with RS485 port, LCD with backlit display of Electricity board approved make, in existing enclosures of HT panel including all necessary accessories for fixing and connection complete as required getting tested and approved from statutory authorities, providing connection/inter-connections as required for complete installation and as instructed by engineer in charge/consultant. (Make - L&T ER300P or equivalent) All TOD meters shall be with communication module with ethernet/Modbus communication protocol for communicating with SCADA software and IBMS.
od335443/2021_2022 : Fabrication, supply, installation, testing and commissioning, including modification with bus bar extnison of existing HT three panel with dust and vermin proof floor mounted free standing cubicle type, 11kV, extensible panel board made out of metal clad fully compartmentalised complete with hinged and earthed front doors interlocked with the earth switch, comprising of one number of 630A VCB outgoing as per IEC 62271 norms. All type tested certificates shall be produced before supply of the panel. Panel shall include all relays and tripping mechanisms and accesories as required as per KSEI standards. Panel shall have cable entry on top side for both outgoing cables with necessary CTs and all accesories as required. VCB shall be with open protocol IEC61850 communication protocol for communicating with SCADA software.<br>1 no:-11kV 630A, 3phase 50Hz, 350MVA, breaking capacity vacuum circuit breaker dust and vermin proof totally enclosed in sheet steel housing, fully inter locked, horizontal draw out and horizontal isolation, indoor truck type with trip free spring closing mechanism with mechanical ON/OFF indicators, earthing terminals automatic safety shutters, complete with auxiliary contacts.<br>Bus bar compartment shall have suitable capacity non-hygroscopic and high dieletric strength SMC/FRP busbar supports with electrolytic aluminium busbars covered with suitable sleeves. WIth breaker control switch, switch with plug point, strip heater, thermostat for space heater, cubicle lamp with switch, seal of bushings including all connections and interconnections. Metering compartments for mounting digital meter and numerical relays for feeder protection, shunt/series trip coil, under voltage release, indication lamps, spring charge, trip circuit healthy, alram, RYM indication cable entry boxes, including all interconnections, providing fire/heat resistant coatings for busbar & CB truck enclosures andpowder coating complete panel as per IS-2516 & IS 3427 with latest amendments complete as required with manually charged spring closing system. It shall also be provided with Instantenous IDMT relay 2 O/C + 1 E/F relay CDAG-51 or Equivalent with high Set, Master Trip Relay. <br>Rate shall be quoted inclusive of modification works of existing HT panel with modification of bus bar, bus bar extention, connection of new cubicle, providing complete accessories in coordination with existing panel and working conditions of site complete as required, testing and commisioning.
SUB MAIN DISTRIBUTION BOARDS(SMDB)
ENERGY MANAGEMENT SCADA SYSTEM
od81190/2020_2021 : POWER QUALITY METER <br>"Supply, installation, testing and commisioning of power quality meter in the main panel and DG synch panel including all connections as required. Multifunction Meter with Power Quality having bright color LCD Display, with Active energy accuracy of Class 0.2S as per IEC 62053-22. The meter should be able to monitor basic parameters of Current, Voltage, Frequency, Active Power, Reactive Power, Apparent Power, Powerfactor, Active Energy, Reactive Energy, Apparent Energy, demand parameters of Active, Reactive, Apparent Power – Total and per phase, Settable accumulation modes, Present & Peak demand with DTS, Synchronization of the measurement window and setting of calculation mode – Block / Sliding. It shoud have a minimum sampling rate of 256 Samples/ Cycle and capable of monitoring Voltage Sags/Swells over waveform Capturing Feature and able to monitor individual harmonics upto 63rd for Voltage & Current. It should have onboard dual Ethernet port and Modbus Mastering capability by connecting Slave devices over RS485 port – 02 Ethernet port & 01 RS485 port. Device needs to be inbuilt with GPS clock (RS485) or IRIG-B (digital input) to +/- 1 millisecond. Meter needs to have 3 digital status inputs for Breaker ON/OFF/ Trip monitoring & 1 KY (form A) energy pulse output for interfacing with other systems. Device should be capable of expandable DI/DO, ADI/ADO. It should have 512MB of standard non-volatile memory for logs of Min/max of instantaneous values, Event logs, Trending/ forecasting, SER (Sequence of event recording) including all accesories and connections and interconnections as required. The meter should be compatiable to be integrated with EMS including all accesories required for the same. The meters should be with Ethernet communication protocol or COMTRADE communication protocol to communicate with SCADA software.<br>"<br>
od81191/2020_2021 : Enclosure for mounting single phase direct 40A multifunction meter alongwith DIN rail providing all connections and interconnections and all accessories as required<br>
od81192/2020_2021 : SINGLE PHASE DIRECT METER<br>Supply, installation, testing and commisioning of Modular Single-Phase Meter DIN Rail Mounted, Direct Input up to 40A, Cl 1.0 Accuracy, with Electro Mechanical 7 Digit Display able to measure Active Energy up to 999999.9 kWh and with Pulse Output for integrating with Energy Management System including all accesories as required to be installed in DBs, enclosures etc as required..The meter shall be with RS485 port for communication with SCADA sooftware<br>
od81193/2020_2021 : Enclosure for mounting three phase direct 125A multifunction meter alongwith DIN rail providing all connections and interconnections and all accessories as required<br>
od81195/2020_2021 : Installation, testing and commisioning of complete system including Software Project Development, Configuration of devices and customization of Dashboard/Report as per requirement of client, providing technical class on operation of software as required to the staff of client side.commisioning charges for installing the whole installation, including converters, ethernet switches and all accesoires required for complete installation of the software and proper management<br>
od81196/2020_2021 : Supply, installation, testing and commisioning of PLC system with ethernet port with 16 digitial input and 16 digital output with expansion module 8 DI, and two numbers UNCO module for integration with existing panels of premisis for integration of exisiting electrical system with SCADA software including all components and accesories required for full integration of existing system with newly proposed SCADA software (For existing MSB of the premisis)<br>
od81197/2020_2021 : Supply and providing termination of RS485 cables as per requirements<br>
od81198/2020_2021 : RS 485 CABLE<br>"Supply, installation testing and commisioning of shielded EIA Industrial RS-485 Cable of 22 AWG stranded tinned copper, datalene insulated. Twisted pairs. Overall standard tinned copper drain wire. Overall 90% coverage tinned copper braid shield. Black UV resistant PVC jacket. with D.C. Resistance of conductor: 14.7 + 1 Ohm / meter, D.C. Resistance of shield: 2.9 + 0.5 Ohm / meter, Capacitance between conductors: 36.1 + 5 pF / meter, Capacitance between one conductor and other conductor connected to shield: 65.6 + 5 pF / meter, to be laid directly in seperate cable tray or directly on wall surface in a neat profesional manner using ties or clamps and the distance between the same shall not be more than 60cm, including all accesories as required for complete installation.<br>"<br>
od81199/2020_2021 : SOFTWARE, SERVER, DESKTOP & OTHER ACCESORIES<br>Supply, installation testing and commisioning of PLC system, programmable according to IEC 61131 standard, with Automatic reporting of system events and presenting them on the display, in the web server, Integrated communication protocols (MODBUS TCP), Integrated security functions like access protection, Support Counters, Timers, Analog input / Outputs, Convenient programming environment by providing analog register and index register, With analog dedicated register (U) and monitoring dedicated function, convenient use for I/O is maximized. with processing time of 0.06μs/Steps, Watchdog timer, Memory error detection, IO error detection, Modbus communication: RS232, RS485 & Ethernet (Dual Port) Modbus TCP/IP, CANopen, DeviceNet, PROFIBUS, RAPIEnet, EtherNet/IP Convenient network-diagnostic function through network & communication frame monitoring including all accesories as required for complete installation for use in panels to be placed inside panels to control ACBs & MCCBs with SCADA software. (Make - L&T XLB-U or equivalent)<br>
od81200/2020_2021 : SOFTWARE, SERVER, DESKTOP & OTHER ACCESORIES<br>Supply, installation testing and commisioning of 24V SMPS power supply for UNCO , PLC modules and other components of SCADA including all accessories as required, installation in wall as necessary <br>
od81202/2020_2021 : SOFTWARE, SERVER, DESKTOP & OTHER ACCESORIES<br>Supply installation, testing and commisioning of UN-CO Modbus Communication module offering “Single Window” platform for controlling operations of ACBs/MCCBs/ATSs. UN-CO can be used for Remote Closing and Opening operation of breakers through Modbus RS485 protocol and uploading breaker status to SCADA. including all accessories as required for complete installation<br>
od81203/2020_2021 : SOFTWARE, SERVER, DESKTOP & OTHER ACCESORIES<br>Supply installation, testing and commisioning of 8 port Unmanaged Ethernet Switches including all accessories as required for complete installation<br>
od81204/2020_2021 : SOFTWARE, SERVER, DESKTOP & OTHER ACCESORIES<br>Supply installation, testing and commisioning of IEC61850 compliant Managed Ethernet Switches 24 port including all accessories as required for complete installation<br>
od81205/2020_2021 : SOFTWARE, SERVER, DESKTOP & OTHER ACCESORIES<br>Supply installation, testing and commisioning of Managed Ethernet Switches 24 port including all accessories as required for complete installation<br>
od81206/2020_2021 : SOFTWARE, SERVER, DESKTOP & OTHER ACCESORIES<br>Supply installation, testing and commisioning of 2 port RS485 to Ethernet Converter including all accessories as required for complete installation<br>
od81207/2020_2021 : SOFTWARE, SERVER, DESKTOP & OTHER ACCESORIES<br>Supply installation, testing and commisioning of 1 port RS485 to Ethernet Converter including all accessories as required for complete installation<br>
od81208/2020_2021 : SOFTWARE, SERVER, DESKTOP & OTHER ACCESORIES<br>Supply instllation, testing and commisioning of 2 nos (one working one redundant) PC server system with following minimum specification, the processor shall be Intel i7, 8 core CPU (3 GHz or better), 64 bit, 16 GB RAM, DVD ROM, 2TB HDD ( Approx. 2 year data saving), USB PORT (2 Nos.), NIC (2 Nos. – 4 ports), 2GB graphics card, 24” inch full LED monitor, USB Keyboard, USB Mouse three button & scrolling and all other accesories required which is required for the proper functioning of the system alongwith workstation furniture for installing the sytem complete as required. The software installed in the system shall be as below but not limited to the same - MS Office 2010, Windows 10, 64 bit, best class Anti-Virus software with 2 year liscence, Adobe Reader and all other basic softwares as required for propoer functioning of the system. Seperate PC shall be included in the scope for web client with Intel i3, dual core CPU (2.3 GHz or better), 64 bit, 4 GB RAM, USB PORTS, 2GB graphics card and all other accesories same as that for PC server system.<br>
od81265/2020_2021 : THREE PHASE DIRECT MULTIFUNCTION METER<br>Supply, installation, testing and commisioning of Multifunction Meter DIN Rail Mounted with Three Phase Direct Input up to 125A, Cl 1.0 Accuracy, with LCD Display, able to measure Parameters Voltage, Current, Active Power & Active Energy and able to communicate via RS485 Modbus Protocol to connect with Energy Management / Building Management System including all accesories as required to be installed in tier DBs, enclosures etc as required..<br>
SAFETY EQUIPMENTS, PREPARATION OF ALL DRAWINGS & LIASIONING WORKS
od81215/2020_2021 : SAFETY EQUIPMENTS<br>"Supply and installation of fire protection Fibre plate, for closing of shafts in wall closings soft Insulation system with fire resistance class to S90 according to DIN 4102 Part 9 approval by DIBt. Fibre Plate shall be withstand not less than 1000°C and the plate shall be pre-coated with moisture resistant ablation coating. System shall be provided in both the side of Openings. Suitable to seal the opening with a combination of cables Pipes and trays. The residual openings and penetration material shall be painted up to 150mm height on both side with ablation coating and Plastic pipe penetrations should be covered by Pipe Sleeves. Product shall be suitable for Solid wall, Partition wall and solid Ceiling. The maximum size of the opening shall be 120 x 200 cm, for solid ceiling any size and the minimum insulation thickness shall be 10 cm. (Approved make – Pyroplate, Fibre soft Insulation system of OBO Bettermann or Equivalent)<br>"<br>
od81216/2020_2021 : SAFETY EQUIPMENTS<br>"Supply and installation of fire resistant cable bandage for wrapping of cable with or without cable trays, plumbing pipes and other combustible pipes/materials in vertical shafts with a fire resistance / Prevention of fire spread class of Min. 120 minutes according to testing standard IEC 60332-3-22: 2000-10. The outer side of the sheet shall be of waterproof coating in Grey colour and the inner side shall be of Fire protection coating Intumescent type in Red colour. The protection sheet shall behave according to DIN EN 13501 - 1 with no restriction in cable types and diameters. (Approved make – Cable Bandage FSB-WB of OBO Bettermann or equivalent)<br>"<br>
od81223/2020_2021 : "Supply and installation of fire resistant mortar of minimum insultation thickness of 150mm for sealing of all opening in floor with fire resistance class EI120 according to testing standard EN 1366-3 (Classification EI120 Acc. EN 13501-2) & DIN 4102 Part 9 DIBt approval Z- 19.15 – 2046. Suitable to seal the openings with all kinds of cables, pipes and cable support system in steel and, Aluminium and plastic profiles. Mortar Harden density shall be 0.8N/mm² and compressive strength shall be 4.0N/mm². The residual openings shall be closed with filler and Plastic pipe penetrations should be covered by bandage. All form work required for installation of the mortar including bar bending works, wire/steel reinforcement if any shall also be considered in this scope of work including all accesories as required for complete installation (Approved make – Pyromix of OBO Bettermann or equivalent) (For all shaft closing to avoid fire penetration)<br>"<br>
od81224/2020_2021 : SAFETY EQUIPMENTS<br>Supply & fixing of Class A Electrical rubber mat, used for high voltage 11kV , 2 Mtr x 1 Mtr size 3 mm thick, as per IS. 15652 - 2006. with ISI certification mark of standard 1 Mtr width.The work includes cleaning of the floor, fixing of insulation mat by using suitable adhesive, waterproofing compound, sealing materials etc., complete as required <br>
od81225/2020_2021 : SAFETY EQUIPMENTS<br>Supply of 1 pair 11 KV rubber hand gloves of approved make.<br>
od81226/2020_2021 : SAFETY EQUIPMENTS<br>Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of providing MS stand for 2 nos of fire buckes, or , duly painted over a coat of primer.<br>
od81227/2020_2021 : SAFETY EQUIPMENTS<br>Supply and providing MS chequered plate of suitable thickness including cutting, welding, painting etc. as required for cable duct covering etc.<br>
od81229/2020_2021 : SAFETY EQUIPMENTS<br>Supply and providing laminated First Aid chart duly framed and placed in a conspicuous location for clear vision.<br>
od81230/2020_2021 : SAFETY EQUIPMENTS<br>Supply and providing First Aid Box.<br>
od81231/2020_2021 : SAFETY EQUIPMENTS<br>Supply & fixing of Class A Electrical rubber mat, used for up to 3.3 kV, Dielectric Strength of 33 kV , 2 Mtr x 1 Mtr size 2 mm thick, as per IS. 15652 - 2006 in front of various type MV panels. as per IS:15652 - 2006 with ISI certification mark of standard 1 Mtr width.The work includes cleaning of the floor, fixing of insulation mat by using suitable adhesive, waterproofing compound, sealing materials etc., complete as required <br>
od81232/2020_2021 : SAFETY EQUIPMENTS<br>Supply and fixing of 4 Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 2171-1999 external epoxy powder coating with PO Red Shade No. 538 of IS 5, Supplied with standard accessories.<br>
od81242/2020_2021 : PREPARATION OF ALL DRAWINGS <br>Preparation of all documents and getting approvals from Inspectorate, submitting of Completion certificates and arranging inspection, getting sanctions and energisation certificates, test reports. Preperation of shop drawings for execution at site and getting them approved by engineer in charge/consultant before execution at site, preperation of As-built drawings of installation upon completion. Obtaining manuals, technical details,as-built/GA drawings/routine and all specified test certificates from manufactures of all equipments from concerned and arranging technical class for maintenance staff of the complete installation for timely maintenance and working and also obtaining all necessary sanctions from relevant regulatory boards, submitting of test certificates of all equipments, arranging technical personal of all equipments installed at site during precommisioning and commisioning, getting their confirmation that installation is as per their standard before commisioning, making the personal availiable during KSEI inspection and making rectification works as commented by KSEI, labeling of all DBs, SMDBs, panels, cable routing and all such marking etc in a professional manner. and commissioning and handing over of the whole installation in a professional manner. All drawings and reports generated shall be printed in visible paper size depending on size. Copies of drawings shall be taken as required for issuing to all concerned agencies working as a part of the project.<br>
od81466/2020_2021 : SAFETY EQUIPMENTS<br>Supply & fixing Laminated drawings of electrical lay out, schematic drawing etc on good frame work.<br>
DATA CENTER CIVIL WORKS
od324999/2020_2021 : "Providing and applying Fire retardant paint of approved make and shade to give an even shade over a primer coat as per manufacturers’ recommendations after applying painting putty to level and plumb and finishing with 2 coats of fire retardant paint. Base coating shall be as per manufacturer’s recommendation for coverage of paint.<br> For all vertical Plain surface.<br> Providing and laying POP punning over cement plaster in perfect line and level with<br>thickness of 10 - 12 mm including making good chases, grooves, edge banding, scaffolding<br>pockets etc."<br>
od325000/2020_2021 : "Providing and fixing metal false ceiling with powder coated 0.5mm thick hot dipped galvanized steel tiles 595 x 595 mm with regular edge (10mm) suitable for 25mm grid supported on suitable powder coated galvanized steel Grid as per manufacturer specification. The same shall be inclusive of cut outs for lighting, <br>Fire detectors, nozzles and 25mm thick glass wool of 16kg.sq.m density wrapped on both sides with<br>aluminium foil and placed over each tile etc."<br>
od325001/2020_2021 : "Supply & fixing of thermal insulation to base floor/RC slab under the raised floor and roof slab with<br>13mm thick, one side aluminium foil faced XLPE / Nitrile rubber of Armflex / Kflex adhered to base<br>floor with manufacturer recommended adhesive."<br>
od325002/2020_2021 : "Providing & fixing steel cementitious raised access floor of Finished Floor height up to<br>450mm to 600mm finished with antistatic high pressure laminate in size 600 x 600 mm x 35 mm with<br>point load 450 kg and uniform distribution load (UDL) 1350 kg per sq. metre as per following<br>specifications: Panel Type - M 1000, Under structure- Edge Support Rigid Grid, Wear resistance (g<br>/cm2) - < 0.08, Bottom profile - Hemispherical shape, Pedestal -all steel construction & silver zinc<br>plated, Exposed surface- Special weather coating on entire surface of the tiles. The same should also<br>be provided with wire manager and tile lifter etc. Providing and fixing 9 mm thick floor insulation<br>below the false flooring and joints should be finished properly as per manufacturer's specification.<br>Should provide grommets for cable entry and the hole cutting should be neat and air tight. Provide a<br>tile lifter with 3 Prongs for maintenance purpose."<br>
od81372/2021_2022 : Providing and fixing Door frame and Shutter made of 46mm thick steel fire check door of 120 minutes fire rating confirming to BS: 476 Part 22 and IS: 3614 Part II for stability and integrity, fabricated with 2 nos. 22 gauge thick galvanized steel sheet with infill of fire rated Acrylic Sealant and non-combustible core bonded to both faces of sheet with lock seam joints at stile edges and internal reinforcement at top, bottom and stile edges for Fire Rating. The door frames are manufactured from 18 gauge thick galvanized steel sheet pressed from to single rebate profile of size 125mm x 75mm. The frames shall be fixed using canon/hilti anchor bolts of size 10mm dia x 100mm long. The door frames and door shutters are finished with powder coating paint. The cost includes providing and fixing of minimum two-hour fire rated stainless steel ball bearing hinges 125 mm x 75mm x 3mm. The cost includes providing opening for vision panel of required size in shutters (cost of glass excluded) and fixing vision panels of specified size with complete fire rated gasket channel & moulding beading and filling the gap between moulding /beading and glass with suitable sealant.<br>
od81373/2021_2022 : Providing and fixing panic bar / latch (single point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.<br>
od81374/2021_2022 : Providing and fixing concealed fire rated 120 minutes RT door closer along with necessary SS screws, bolts, nuts, washers etc. as per approved samples complete as per the direction of the Engineer-in-charge.<br>
od81378/2021_2022 : Supply of vision panel in fire rated doors of specified sizes made out of minimum 5 mm thick clear fire rated glass (imported) for 120 minutes fire rating of fully transparent in fire/non-fire conditions having minimum 93% transparency, in accordance with IS : 3614 Part -II and BS : 476 Part 20& 22 , for 120min. fire rating for stability and integrity and insulation criteria .<br>
PART A-SANITARY FIXTURES AND FITTINGS
od324916/2020_2021 : Providing and fixing white vitreous china pedestal type floor mounted water closet (European type W.C. pan) with seat and lid, 3/6 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (twin flush), with flow rate of 4.5 lpm (50 % below griha base rate) including flow regulator with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid.
od93174/2020_2021 : Supply, Installation, testing and commissioning of Vitreous China wall mounted European water closet - with seat and cover (with 's' trap of IS specification make and approved by the consultant) , MS / CI chair brackets, fischer bolts with CP bolts / nuts and with concealed cistern with CP flanges with flow rate of 4.5 lpm (50 % below griha base rate) including flow regulator, solid plastic seat and lid with heavy duty CP hinges and rubber buffers and flap etc. The work shall include cutting making of walls and floors etc. Notes: Necessary consumables like brass screws, CP extension nipple of approved make, dia and length, wooden plugs, white cement, sealants etc., required if any, shall be arranged by the contractor. Only drilling machines shall be used for making the holes in the walls for fixing, no wall jumper and hammer will be allowed.(EWC+Cistern with frame & Face plate)
od83410/2020_2021 : Supply & Fixing of colour vitreous china counter top wash basin- installed on granite/ marble with CI / MS brackets, 32mm dia CP waste coupling with plug and chain, PVC / CP cold water supply connecting pipe, one nos of 15mm dia CP angle stop cock for cold water supply lines with wall flange etc as per IS specification make and approved by the consultant. The works shall include cutting in walls and making good the walls & floors. .(Granite / Marble counter will be installed by other agency)
17.7.4 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x400mm with single 15 mm C.P.brass pillar taps
od324961/2020_2021 : Providing and fixing brass bib cock of approved quality having low flow fixture with flow rate of 5 lpm (50 % below griha base rate) including flow regulator confirming to IS standards.
od324969/2020_2021 : Providing and fixing of 15 mm C.P. brass sink cock of low flow fixture category wall mounted with 188mm long swivel spout and wall flange with flow rate of 5 lpm (50 % below griha base rate) including flow regulator with all fittings and brackets of approved quality
od324970/2020_2021 : Providing and fixing of 15 mm C.P. brass pillar taps of standard pattern having low flow fixture with flow rate of 5 lpm (50 % below griha base rate) including flow regulator with all fittings and brackets of approved quality
od250835/2021_2022 : Providing and fixing of 15 mm C.P. brass pillar taps with lev.handle for elbow operated of standard pattern having low flow fixture with flow rate of 5 lpm (50 % below griha base rate) including flow regulator with all fittings and brackets of approved quality
od250836/2021_2022 : Providing and fixing of 15 mm C.P. brass pillar taps side single lever mono sink mixer with s of standard pattern having low flow fixture with flow rate of 5 lpm (50 % below griha base rate) including flow regulator with all fittings and brackets of approved quality
od250838/2021_2022 : Providing and fixing of 15 mm C.P. brass pillar taps single lever basin mixer without popup w of standard pattern having low flow fixture with with flow rate of 5 lpm (50 % below griha base rate) including flow regulator including all fittings and brackets of approved quality
od324971/2020_2021 : Supply, installation, testing and commissioning of mixer type shower system consisting of conversion bend for overhead shower with wall flanges and shower arm ,shower head etc having low flow fixture with flow rate of 5 lpm (50 % below griha base rate) including flow regulator as per IS specification make and approved by the consultant, complete in every respect including, cutting, chasing & making good the walls .
od250881/2021_2022 : Supply and fixing of shower with divertor and spout with inlet body, conversion bend for overhead shower with wall flanges, shower arm, valve plate lever, etc with with flow rate of 5 lpm (50 % below griha base rate) including flow regulator as per IS specification confirming to green building norms with low flow fixture unit , complete in every respect including, cutting, chasing & making good the walls .
17.10.1.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm
17.10.2.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm
17.10.2.2 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x460 mm bowl depth 200 mm
od314461/2021_2022 : Providing and fixing of cleaner's sink of 600x520 mm including C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
od318765/2021_2022 : Providing and fixing of Hospital SS Bed Pan Sink SS 304/18 SWG SIZE 850 MM x 600 MM X 300 MM with 10 Liter CI High Level Flushing Cistern Flush Pipe, C.I./M.S. (Painting with 3 Coats of White Paint Complete with accessories.)
od250521/2021_2022 : Providing and fixing white vitreous china battery based infrared sensor operated urinal having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets with flow rate of 2 lpm (50 % below griha base rate) including flow regulator according to manufacturers specification and direction of Engineer - in-charge.
od89097/2020_2021 : Providing & fixing, testing and commissioning of approved make & white urinal division plate of size 90 x320x720mm and fixed to wall by using CP brass screws etc. complete as per specifications.
17.8 : Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
17.11.2 : Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm
17.34.1 : Providing and fixing toilet paper holder:C.P. brass
od170256/2020_2021 : Providing and fixing CP towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour.
od170257/2020_2021 : Providing and fixing CP towel rail complete with brackets fixed to Wall with CP brass screws with concealed fitting arrangement of approved quality and colour<br>450 mm long towel rail .
od170258/2020_2021 : Providing and fixing CP towel rail complete with brackets fixed to Wall with CP brass screws with concealed fitting arrangement of approved quality and colour<br>600 mm long towel rail .
od170259/2020_2021 : Providing and fixing CP Soap Dish Holder having concealed fittings arrangements.
od170260/2020_2021 : Providing & fixing, testing and commissioning of approved make CP shower unit with concealed part for concealed stop cock and spout suitable for 20mm pipeline with inner head with out exposed parts with 220mm long bend pipe for over head shower with CP wall flanges.
od170261/2020_2021 : Providing and fixing CP Waste Coupling for wash basin and sink, of approved quality and colour.<br>Waste coupling-full threaded 32mm size
17.70.1 : Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the center of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore
od250344/2021_2022 : Supplying and fixing CP Health Faucet superior quality with with flow rate of 5 lpm (50 % below griha base rate) including flow regulator, cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge
17.28.1.1 : Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC. waste fittings complete.Semi rigid pipe32 mm dia
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
od250884/2021_2022 : Providing and fixing C.P brass long nose bib cock of approved quality with flow rate of 5 lpm (50 % below griha base rate) including flow regulator to IS standards and weighing not less than 810 gms. 15 mm nominal bore
od257819/2021_2022 : Providing and fixing of CP elbow operated bib cock 15mm with flow rate of 5 lpm (50 % below griha base rate) including flow regulator and of approved quality & make. 15 mm nominal dia
od158032/2020_2021 : Providing and fixing of approved make foot operated faucet with hose pipes and spout with CP flanges, fixed with SS screws etc complete.
od90052/2020_2021 : Providing and fixing Disabled Toilet, Complete Set, including White Floor Mounted Water Closet with flow rate of 4.5 lpm, Plastic Cistern , Lid, Antimicrobial Seat Cover etc, Faucet/Tap with spactula lever and with 1no of Hinged Arm, 760mm. Long, 2nos of Grab Rail, each of 600mm. long, health faucet with flow rate of 5 lpm, pillar tap with flow rate 5 lpm and with all necessary accessories and fixed with Brackets Expansion/Rawl sleeves, stainless steel/ brass bolts/screws, nuts, washers etc, including cutting and making good the walls and floors wherever required. including all as per manufacture's and to the approval of Engineer-in-charge based on below 50% griha base rate.
od90131/2020_2021 : Fixing of superior quality Rob hook with brackets and flange with concealed brass screws etc as per IS specification make and approved by the client / consultant, including cutting & making good the walls.
od89107/2020_2021 : Providing and fixing of automatic sensing high jet speed hand dryer both hot and hot air of approved quality conforming to IS standards.
17.75 : Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2" BSP thread and shapes, weighing not less than 60 gms.
17.7.9 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon Type wash basin of size 660x460 mm with single 15 mm C P. brass pillar taps with elbow operated levers ISI marked
18.84.1 : Providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology.15 mm nominal bore
od156926/2020_2021 : Providing and fixing of approved make CP grab bar wall mounted 350mm long with CP flanges, fixed with SS screws complete for all patient Toilet.
od156927/2020_2021 : Providing and fixing of approved make CP grab bar wall mounted 600mm long with CP flanges, fixed with SS screws complete for all patient Toilet.
od157739/2020_2021 : Providing and fixing of wall mounnted sensor soap dispenser of 1000ml capacity with ac/dc operated type of standard shape with bracket of the same materials with snap fittings of approved quality and colour
od157795/2020_2021 : Providing and fixing of SS hand rub stand hand touch free foot operated sainitiser stand easy to operate with any size of dispenser pump bottle of size (39X4X10.5")and weight not less than 4.25kg with solution.
od157833/2020_2021 : Providing and fixing of 304 grade stainless steel wall mountd slope hopper sink of size 1000mm x600mm. with back or top entry flushpipe connection drain board including flush valve system for flushing, sink size of 365mm dia, one no of CP elbow operated bib cock 15mm of approved quality,one no of sensor operated bibcock with ac/dc power supply,3 nos of angle valve,one no of health faucet CP ,connection pipes etc complete with wall mounting brackets ,The drain outlet shall be of 110mm dia size with the option of P or S trap outlet
17.71 : Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms
18.16.2 : Providing and fixing brass stop cock of approved quality :20 mm nominal bore
od170304/2020_2021 : Providing and fixing brass concelaed stop cock of approved quality :<br>32 mm nominal bore
od170305/2020_2021 : Providing and fixing brass concealed stop cock of approved quality :<br>25 mm nominal bore
od158261/2020_2021 : Supply,Installation, testing and commission, of floor mounted 50 litre water purifier with SS 304 grade water tank having input water source filtering capabilty of online UV water purifier,electrical and non storage:electrical purification-suitable for direct water suppy,UV: Suitable for municipal water,purifies microbes levels with hot and cold water dispenser (50 ltrs hot and 50 ltrs normal water storage having automatic repurification with ISO Certified system complete with all fittings and acessories.The unit includes RO membarne,filters etc.Warranty min 5 years and CAMC- 5 years mandatory.
od170400/2020_2021 : Supply,Installation, testing and commission, of scrub sink with ss grade 304,1.2mm thickness size: with taps -1no,pu pipe,male/female connectors(8nos),foot operated valve(1no etc ) im: 150X60X90+60(LWH) <br>• MADE OF 1.50MM THICK SS 304 SHEET AND TUBES <br>• BACK SPLASH 60CM , side splash 15cm<br>• WALL/FLOOR MOUNTED <br>• PERFORATED DRAIN BOARD & HIGH QUALITY WASTE COUPLING<br>• SENSOR CONTROLLED MIXER TAP WITH AC/DC POWER SUPPLY-OF 1 no<br>• KNEE OR FOOT OPERATED TAP OF 2 NOS<br>• SENSOR COTROLLED SOAP DISPENSOR -2Nos with 1 lire capacity, SS body,
od170708/2020_2021 : Supply,Installation, testing and commission, of water purifier with input water source filtering capabilty of RO ,UV MTDS 7Ltr water purifier,6 stages of purification electrical and non storage:electrical purification-suitable for direct water suppy,UV: Suitable for municipal water,purifies microbes levels with ISO Certified system complete with all fittings and acessories.The unit includes RO membarne,filters etc. Warranty-5 years +CAMC-5 years
od194703/2020_2021 : Supply,Installation, testing and commission, of eye washer SS-304 type-10 inch size round type,foot operated with shower height of1020mm
PART B-WATERSUPPLY PIPES AND FITTINGS
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes
18.8.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes
18.8.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm nominal outer dia pipes
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes
18.9.7 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work62.50 mm nominal inner dia pipes
18.9.8 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work75 mm nominal inner dia pipes
18.9.9 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work100 mm nominal inner dia pipes
18.9.10 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work150 mm nominal inner dia pipes
od90120/2020_2021 : Providing and fixing UPVC) pipes, for cold water supply, including all UPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.- 20 mm nominal outer dia Pipes<br>
od90121/2020_2021 : Providing and fixing UPVC) pipes, for cold water supply, including all UPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.- 25 mm nominal outer dia Pipes
od90122/2020_2021 : Providing and fixing UPVC) pipes, for cold water supply, including all UPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and the cos of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.- 32 mm nominal outer dia Pipes
od315533/2021_2022 : Providing and fixing UPVC pipes, having mfor cold water supply including all UPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-150 mm nominal outer dia Pipes- SCH 80
od315534/2021_2022 : Providing and fixing UPVC pipes, having mfor cold water supply including all UPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-100 mm nominal outer dia Pipes SCH 80
od315535/2021_2022 : Providing and fixing UPVC pipes, having mfor cold water supply including all UPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-80 mm nominal outer dia Pipes SCH 80
od315536/2021_2022 : Providing and fixing UPVC pipes, having mfor cold water supply including all UPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-65 mm nominal outer dia Pipes
od315537/2021_2022 : Providing and fixing UPVC pipes, having mfor cold water supply including all UPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-50 mm nominal outer dia Pipes
od315538/2021_2022 : Providing and fixing UPVC pipes, having mfor cold water supply including all UPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-40 mm nominal outer dia Pipes
od315539/2021_2022 : Providing and fixing UPVC pipes, having mfor cold water supply including all UPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-20 mm nominal outer dia Pipes
od315540/2021_2022 : Providing and fixing UPVC pipes, having mfor cold water supply including all UPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-32 mm nominal outer dia Pipes
od315541/2021_2022 : Providing and fixing UPVC pipes, having mfor cold water supply including all UPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-25 mm nominal outer dia Pipes
od194629/2020_2021 : Supply, installation, testing and commissioning of PRV brass material make with Screwed Female Ends to IS 554 / BS 21 / ISO 7 and with features like ideal for sensitive and a consistent fluid regulation, Diaphragm-less, Piston Type, with Nitrile Rubber ‘O’Rings, facility provided to install a Pressure Gauge of 1/4′′ BSP size to gauge the critically relevant Outlet Pressure,and lines including cost of necessary flanges, nut, bolt, and washers etc complete -50mm dia
od194630/2020_2021 : Supply, installation, testing and commissioning of PRV brass material make with Screwed Female Ends to IS 554 / BS 21 / ISO 7 and with features like ideal for sensitive and a consistent fluid regulation, Diaphragm-less, Piston Type, with Nitrile Rubber ‘O’Rings, facility provided to install a Pressure Gauge of 1/4′′ BSP size to gauge the critically relevant Outlet Pressure,and lines including cost of necessary flanges, nut, bolt, and washers etc complete -40mm dia
od194631/2020_2021 : Supply, installation, testing and commissioning of PRV brass material with Screwed Female Ends to IS 554 / BS 21 / ISO 7 and with features like ideal for sensitive and a consistent fluid regulation, Diaphragm-less, Piston Type, with Nitrile Rubber ‘O’Rings, facility provided to install a Pressure Gauge of 1/4′′ BSP size to gauge the critically relevant Outlet Pressure,and lines including cost of necessary flanges, nut, bolt, and washers etc complete -32mm dia
od194632/2020_2021 : Supply, installation, testing and commissioning of PRV brass material make with Screwed Female Ends to IS 554 / BS 21 / ISO 7 and with features like ideal for sensitive and a consistent fluid regulation, Diaphragm-less, Piston Type, with Nitrile Rubber ‘O’Rings, facility provided to install a Pressure Gauge of 1/4′′ BSP size to gauge the critically relevant Outlet Pressure,and lines including cost of necessary flanges, nut, bolt, and washers etc complete -25mm dia
18.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
od171441/2020_2021 : Providing and fixing ball valve (brass) of approved quality with all acessories, High or low<br>pressure, complete with all acessories :32mm dia
od171427/2020_2021 : Providing and fixing ball valve (brass) of approved quality, High or low<br>pressure, with all accessories :40mm dia
od171558/2020_2021 : Supply and fixing cast iron lever operated slim seal type butterfly valves of CI body and spheroidal graphite iron disc (SG iron),with nitrile rubber seal, tested to 10 kg / sq.cm Confrming to BS 5155 / MF6 standards and including a set of GI flanges as per BS-10 table 1 including bolt nuts, and Neoprene rubber gaskets etc.,complete as required.150 mm nominal bore
od171559/2020_2021 : Supply and fixing cast iron lever operated slim seal type butterfly valves of CI body and spheroidal graphite iron disc (SG iron),with nitrile rubber seal, tested to 10 kg / sq.cm Confrming to BS 5155 / MF6 standards and including a set of GI flanges as per BS-10 table 1 including bolt nuts, and Neoprene rubber gaskets etc.,complete as required.100 mm nominal bore
od171451/2020_2021 : Supply and fixing cast iron lever operated slim seal type butterfly valves of CI body and spheroidal graphite iron disc (SG iron),with nitrile rubber seal, tested to 10 kg / sq.cm Confrming to BS 5155 / MF6 standards and including a set of GI flanges as per BS-10 table 1 including bolt nuts, and Neoprene rubber gaskets etc.,complete as required.80 mm nominal bore
od171452/2020_2021 : Supply and fixing cast iron lever operated slim seal type butterfly valves of CI body and spheroidal graphite iron disc (SG iron),with nitrile rubber seal, tested to 10 kg / sq.cm Confrming to BS 5155 / MF6 standards and including a set of GI flanges as per BS-10 table 1 including bolt nuts, and Neoprene rubber gaskets etc.,complete as required.65 mm nominal bore
od171453/2020_2021 : Providing and fixing ball valve (brass) of approved quality, High or low<br>pressure, with all fitting acessories :50 mm nominal bore
18.9.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work20 mm nominal outer dia pipes
18.9.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work25 mm nominal outer dia pipes
18.9.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work32 mm nominal outer dia pipes
18.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontal
18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal
18.19.5.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):65 mm nominal boreHorizontal
18.19.6.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):80 mm nominal boreHorizontal
18.21.2.1 : Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore
18.60.1 : Providing and fixing enclosed type water meter (bulk type) conforming to IS: 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. ( The tail pieces if required will be paid separately):80 mm dia nominal bore
od90148/2020_2021 : Providing, fixing, testing and commissioning of brass body nickel plated automatic air release valves with necessary GI Specials, thread, holdtight, brass spindle, NBR and elastomeric, stainless steel spring polypropylenic float at the top most points of water supply distribution ring main. 20 mm dia.
od90149/2020_2021 : Supplying & Fixing at site in position Fabricated u PVC Astm Sch 80 Puddle flanges in the underground and overhead water tanks as per the drawings and the requirement of the Project Manager.50mm dia <br>
od90150/2020_2021 : Supplying & Fixing at site in position Fabricated u PVC Astm Sch 80 Puddle flanges in the underground and overhead water tanks as per the drawings and the requirement of the Project Manager.65mm dia
od352730/2021_2022 : Supplying & Fixing at site in position Fabricated u PVC Astm Sch 80 Puddle flanges in the underground and overhead water tanks as per the drawings and the requirement of the Project Manager. 80mm dia puddle flange
od158074/2020_2021 : Supplying & Fixing at site in position Fabricated u PVC Astm Sch 80 Puddle flanges in the underground and overhead water tanks as per the drawings and the requirement of the Project Manager.-150mm dia
od158075/2020_2021 : Supplying & Fixing at site in position Fabricated u PVC Astm Sch 80 Puddle flanges in the underground and overhead water tanks as per the drawings and the requirement of the Project Manager.100mm dia puddle flange
od90152/2020_2021 : Supply and fixing of plastic ball float valve with gun metal lever of IS specification make and approved by the client / consultant for muncipal water inlet pipe to UG sump. 25 mm dia
od170474/2020_2021 : Providing and fixing grating of CP brass 2 in 1, gratings 150mm outer & 100mm inside with screwing facility approved quality and colour.
od324351/2020_2021 : Providing and fixing of water meter which is to be modbus compactibility with all acessories 50mm dia
od324352/2020_2021 : Providing and fixing of MODBUS water meter with all fittings and accessories which is compactible with BMS system-32mm dia
od253698/2021_2022 : Supply,Installation, testing and commissioning of smart water meter confirming to IS 4064(1) of multijet class B magnetic type 100mm meter battery powered with neccesary fittings such as threaded pieces, unions, check nuts complete as required. 65mm dia
od253699/2021_2022 : Supply,Installation, testing and commissioning of smart water meter confirming to IS 4064(1) of multijet class B magnetic type 100mm meter battery powered with neccesary fittings such as threaded pieces, unions, check nuts complete as required.80mm size
od253713/2021_2022 : Supply,Installation, testing and commissioning of smart water meter confirming to IS 4064(1) of multijet class B magnetic type 100mm meter battery powered with neccesary fittings such as threaded pieces, unions, check nuts complete as required. 100mm dia
od253725/2021_2022 : Supply,Installation, testing and commissioning of smart water meter confirming to IS 4064(1) of multijet class B magnetic type 100mm meter battery powered with neccesary fittings such as threaded pieces, unions, check nuts complete as required. 150mm dia
od253714/2021_2022 : Supply,Installation, testing and commissioning of data concentrator panel for water meter reading which is to be compactible with BMS integration software.
PART C- DRAINAGE PIPES-SOIL ,WASTE ,VENT PIPES AND FITTINGS
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2
50.18.7.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall
50.18.8.8.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2
50.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
od352811/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall
od352817/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
50.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2
50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
od345536/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. external work-exposed on wall, including cutting chases and making good the wall etc. 160mm dia 6Kgf/cm2
od318165/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. external work-exposed on wall, including cutting chases and making good the wall etc. 200mm dia 6Kgf/cm2
od318802/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. external work-exposed on wall, including cutting chases and making good the wall etc. 250mm dia 6Kgf/cm2
od342981/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m<br>spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints<br>complete as per direction of Engineer-in-Charge. external work-exposed on wall, including cutting chases<br>and making good the wall etc. 300mm dia 6Kgf/cm2
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2
od336373/2020_2021 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 200 mm dia 6 Kgf/cm2
od166745/2021_2022 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 250 mm dia 6 Kgf/cm2
od342986/2021_2022 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent<br>cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge 300 mm dia 6<br>Kgf/cm2<br>
50.18.8.7.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc 63 mm pipe 4 kgf/ cm2
od353093/2021_2022 : Providing and fixing PVC pipes including fixing the pipe, fittings with clamps/clips at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall
od353126/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes, fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall
50.18.9.19.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall
od318558/2021_2022 : Providing, Fixing, Jointing and Testing in position the following PVC-U pipes with fittings confirming to IS:15328 (SN8) for External Sewer System cut to required length. Pipe should laid below ground level in trenches upto required depth including excavations in all kind of soil (hard rock), dewatering, refilling, watering, ramming and removing the surplus excavated material and making good the same complete as required. Cost shall be inclusive of providing protection to pipe all round/haunches as per specification. 110 mm dia
od318776/2021_2022 : Providing, Fixing, Jointing and Testing in position the following PVC-U pipes with fittings confirming to IS:15328 (SN8) for External Sewer System cut to required length. Pipe should laid below ground level in trenches upto required depth including excavations in all kind of soil (hard rock), dewatering, refilling, watering, ramming and removing the surplus excavated material and making good the same complete as required. Cost shall be inclusive of providing protection to pipe all round/haunches as per specification. 200mm dia
od318559/2021_2022 : Providing, Fixing, Jointing and Testing in position the following PVC-U pipes with fittings confirming to IS:15328 (SN8) for External Sewer System cut to required length. Pipe should laid below ground level in trenches upto required depth including excavations in all kind of soil (hard rock), dewatering, refilling, watering, ramming and removing the surplus excavated material and making good the same complete as required. Cost shall be inclusive of providing protection to pipe all round/haunches as per specification. 160 mm dia
19.7.1.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
19.21.1 : Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix( 1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete.For pipes 100 to 250 mm diameter
19.27.1 : Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 ( 1 cement: 4 coarse sand) including 500x450 mm pre- cast R.C.C. horizontal grating with frame complete as per standard design:With common burnt clay F.P.S(non modular) bricks of class designation 7.5
19.8.1.1 : Extra for depth for manholesSize 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5
od90439/2020_2021 : Providing and fixing of floor traps (4'') and fixing CP gratings of approved quality and colour. Rectangular type with openable circular lid. 150 mm nominal size square 100 mm diameter of the inner hinged round gratings to toilet floors and making good the concrete floor as per direction of engineer in charge
od171594/2020_2021 : Supplying, Installing & Testing at site in position Polypropylene Floor Trap (sound level 13 dB @ 4L/sec) supporting on G.I. slotted rails (1.6 mm thick), Full threaded rod, Anchor Fasteners etc at site.
18.58.2.1 : Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid150 mm nominal size square 100 mm diameter of the inner hinged round grating
19.4.1.1 : Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5
od171681/2020_2021 : Providing and fixing of P traps (4'') 110MM X110MM dia and making good the concrete floor as per direction of engineer in charge
od170769/2020_2021 : Supplying and fixing D.I. cover for manholes of size 300x300mm inside of heavy duty type :<br>C.I. cover (heavy duty) the weight of the cover to be<br>not less than 90 kg
od170980/2020_2021 : Supplying and fixing D.I. cover for manholes of size 600x600mm inside of heavy duty type :<br>D.I. cover (heavy duty) the weight of the cover to be<br>not less than 110 kg including manhole frame
19.30.3.1 : Constructing brick masonry chamber for underground C.I. inpection chamber and bends with bricks in cement mortar 1:4 ( 1 cement: 4 coarse sand) C.I.cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15 kg), R.C.C top slab with 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x850 mm and 45 cm deep for pipe line with three or more inlets:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
50.18.9.21.7 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl
50.18.9.22.8 : Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl
od90459/2020_2021 : Supplying, Installing & Testing at site in position PVC Rodding Eye (6 kg/cm2) complete in all respects.<br>110 mm dia <br>
od90460/2020_2021 : Supplying, Installing & Testing at site in position PVC Rodding Eye (6 kg/cm2) complete in all respects.75 mm dia
od354002/2020_2021 : Providing, fixing and installing readymade septic tank of 10.0 KLD capacity, Type VI of 2.0m dia X 4.0m length of United or equivalent make, double walled for extra safety with minimum 10 mm wall thickness, finished smooth with contours of structural ribs confirming to ASTM standards and lined inside with black colour to maintain 100% capacity to facilitate bacterial growth with standard manhole, manhole cover and provision for inlet, outlet, vent and necessary FRP straps, eye bolt, wire rope, turn buckle for anchoring and factory made concrete blocks to counter buoyancy etc all complete for finished item of work to the satisfaction of Engineer-in-charge and including cost for earthwork excavation, filling, providing cement concrete for plinth/sub-base, RCC and necessary reinforcement as required and as directed by Engineer-in-charge.
19.32.1 : Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
od331126/2021_2022 : Supplying, Installing & Testing at site in position low noise 3 layered poly propylene pipes & push fit fittings(PP) of sound level 13 dB @ 4L/sec for non pressurized domestic drainage in accordance with system standards of DIN 4102, the density of the pipe & fittings material should be 1.9 g/cm3, clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete including cutting and making good the walls and floors as required at site for CSSD ROOM - DN 56 - 58mm dia<br><br>
od331135/2021_2022 : Supplying, Installing & Testing at site in position low noise 3 layered poly propylene pipes & push fit fittings(PP) of sound level 13 dB @ 4L/sec for non pressurized domestic drainage in accordance with system standards of DIN 4102, the density of the pipe & fittings material should be 1.9 g/cm3, clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete including cutting and making good the walls and floors as required at site for CSSD ROOM - DN70 - 78mm dia<br><br>
od331137/2021_2022 : Supplying, Installing & Testing at site in position low noise 3 layered poly propylene pipes & push fit fittings(PP) of sound level 13 dB @ 4L/sec for non pressurized domestic drainage in accordance with system standards of DIN 4102, the density of the pipe & fittings material should be 1.9 g/cm3, clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete including cutting and making good the walls and floors as required at site for CSSD ROOM - DN100 - 110 mm dia<br><br>
od331148/2021_2022 : Supplying, Installing & Testing at site in position low noise 3 layered poly propylene pipes & push fit fittings(PP) of sound level 13 dB @ 4L/sec for non pressurized domestic drainage in accordance with system standards of DIN 4102, the density of the pipe & fittings material should be 1.9 g/cm3, clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete including cutting and making good the walls and floors as required at site for CSSD ROOM - DN150 - 160mm dia<br><br>
PART D-MAN HOLE COVERS,CHAMBERS ,CORE CUTTING
12.44 : Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
19.7.1.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
19.8.1.1 : Extra for depth for manholesSize 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5
19.7.3.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x 90 cm and 90 cm deep including C.I. cover with frame ( heavy duty ) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg ( weight of cover 108 kg and weight of frame 100 kg)With common burnt clay F.P.S. ( non modular) bricks of class designation 7.5
19.8.2.1 : Extra for depth for manholesSize 120x90 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5
18.36.1 : Constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I surface box 350x350 mm top and 165 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 grades stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Part E -PUMPS AND FITTINGS
od343295/2021_2022 : Supply , Erection, testing and commissioning of Hydro pneumatic system comprising of following. 4nos stainless steel construction driven by suitable KW motor having an rpm of 2900, 415V, 50Cycles Ac 3Phase TEFC vertical flange motor. (Out of 4 pumps one is standby). A vertical diaphragm tank shall be connected along with the system. The tank shall be fabricated from prime quality steel for long life. the tanks shall be given long lasting EPOXY paint treatment for weather protection their shall be complete water and air inside the tank. Variable speed drive control panel with 3nos of VFD. Suitably rated MCCBs isolators Voltmeter , Ammeter (4nos.), indicating lamps single phasing preventer, pressure switches, pressure indicators (digital) etc. shall be provided. The control circuit shall be said such that all pumps are of individual VFD. The pump shall have pressure sensors to keep the pressure on the. CAPACITY - EACH PUMP-6LPS @85 MTR HEAD
od253420/2021_2022 : Supply, Installation ,testing and commissioning of Hot water recirculation pump of HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP CAPACITY: 0.5lps @ 45 MTR head MOTOR:2900 RPM with Temperature Controller, Sensor, Accessories.
od91469/2020_2021 : Providing & fixing, testing and commissioning of SS centrifugal Waste water Transfer Pump(grinder pump), for pumping waste water/ Kitchen waste/ sewage waste from collection pit to Sewage treatment plant, with including control panel, solenoid valves, level switches, control wires etc. (1Working pump+standby) with suitable HP MAKE : Capacity:200lpm@30mtr head
od88602/2020_2021 : Providing & Fixing, testing and commissioning of Automatic Three phase water level controllers with level sensors for submersible pump shall have the following features <br>a)Switch off the motor when the water level in tank reaches a preset level below the over flow pipe.<br>b)Switch ON the motor if the water level in tank goes down below a preset value near.<br>c)Switch off the motor in the event of dry running.<br>d)Manual bypass mode.<br>
od106339/2020_2021 : Supply & Installation of Heat pump (5000 LPD Tank with 36 Kw)-HOT WATER STORAGE TANK Supply & Installation of 5000 LTRS MS Hot<br>water storage Tank with – 4 kg/sq.cm pressure<br>& MS stand.<br> Heat pump – Output 36 kW with flow of (775 LPH).<br>Circulation pump b/w Heat Pump & Tank.<br>CPVC Piping with valves & Fittings b/w Tank & Heat Pump including Control Panel & Wiring with all acessories<br> Moc: SS material ,refrigerant type-R410a,tank material -6-8mm thickness,inner coating-2 coats epoxy anti rust coating,rockwool insulation-100mm, aluminium 22swg tank outer coating,cpvc-SDR11 or sch 80
od347669/2021_2022 : Supply, Installation, Testing & Commissioning of Ultra-Filtration Plant- Incl. Skid, Dosing Pumps, Solenoid Valve based Operation and PLC based Control, Capacity - 12 m3/hr, with Low Pressure Membrane, Flux Rate for Design – 200 LMH, Pressure Vessel rating 10 Bar, with Feed Pumps (1 Working+ 1 Standby), Backwash Pumps (1 Working), CIP Pump in SS 304 Construction (1 Working), 20” Jumbo Cartridge Filters in the Inlet and in CIP Inlet Lines, Dosing Arrangements, Chemical Tank, Check Valves, Hand Valves, Pressure Guages, Rotameters for Flow Monitoring etc Complete with all electrical and plumbing works. ( One for cooling tower makeup water and one for flushing).
od194696/2020_2021 : Supply of cold water hign pressure cleaner with Power supply 1Ph / 230 V / 50 Hz, Flow rate - 230 to 560 liters/hrs,Operating pressure - 150 bar,Max. feed temperature - 60 °C,Motor power - 3.1 kW,Weight -30 Kg,Dimensions (L x W x H) - 360×375×925 mm,Hose standard - 10 m including pipe cleaning hose-Pipe cleaning hose, ID 6, 20 m (61100080)-1no,Pipe cleaning nozzle (5.763-015.0)-1 no
CABLES
od91482/2020_2021 : Providing of 4 pair 1.5 sq mm cable as control cable of liquid water level controller through a ISI Heavy duty 20mm conduit<br>
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
Oxygen Supply System
od176598/2020_2021 : Supply, Installation, Testing and commissioning of fully automatic Oxygen Control Panel with minimum flow rate of 1790 LPM
od4622/2021_2022 : Supply, Installation, Testing and commissioning of Duplex Mediacl grade Oxygen Generator system including two set oxygen generators, two set Oxygen analyszer, two set Air compressor, two set refrigerent dryer, two set filtration system. one air receiver of 5000 ltr capacity, one oxigen receiver of 4000 ltr capacity, oxygen flow meters, UPS, interconnecting pipelines and all required accessories to ensure Medical grade oxygen and as per HTM 02-01 standard including electrical control panel including starter and necessary connections etc. The ogygen generator shall be class 2 certified medical devise. The installation must fully comply with the standard EN ISO7396-1/NFPA 99 and the produced air must be for medical use according to the European Pharmacopoeia as per the tech spec. Each generator should have minimum oxygen delivery of 1790 LPM . Third party certification to be produced for medical grade oxygen quality and design output flow value verification.<br>
od4967/2021_2022 : Supply, Installation, Testing and commissioning of Oxygen Manifolds - 2 banks x 10 cylinders with all accessories etc.<br><br>
od4970/2021_2022 : Supply, Installation, Testing and commissioning of Emergency Cylinder Manifold 2 bank x 5 cylinders with emergency Oxygen high flow regulator with gauges and safety valves with all accessories etc.<br>
Nitrous Oxide Supply System
od176652/2020_2021 : Supply, Installation, Testing and commissioning of fully automatic N2O Control Panel with minimum flow rate of 500 LPM<br>
od176653/2020_2021 : Supply, Installation, Testing and commissioning of N2O Manifold - 2 banks x 5 cylinders with all accessories etc.<br>
od176654/2020_2021 : Supply, Installation, Testing and commissioning of Emergency N2O Cylinder Manifold -1 bank x 2cylinders with emergency N2O high flow regulator with gauges and safety valves with all accessories etc.<br>
Carbon dioxide Supply System
od176711/2020_2021 : Supply, Installation, Testing and commissioning of fully automatic CO2 Control Panel with minimum flow rate of 500LPM and heater is to be provided<br>
od176712/2020_2021 : Supply, Installation, Testing and commissioning of CO2 Manifold - 2 banks x 3 cylinders with all accessories etc.<br>
Nitrogen Supply System
od177224/2020_2021 : Supply, Installation, Testing and commissioning of fully automatic Nitrogen Control Panel with minimum flow rate of 500LPM or above<br>
od177225/2020_2021 : Supply, Installation, Testing and commissioning of Nitrogen Manifold - 2 banks x 3 cylinders with all accessories etc.<br>
Compressed Air Plant
od177307/2020_2021 : "Supply, Installation, Testing and commissioning of Triplex Mediacl grade compressed Air System must have 3 nos medical grade air cooled screw compressor in compact super sound absorbing tower design complete with all required cooling, control and monitoring facilities for operations in system with 3 compressors, a control panel, 2 air receivers 2000 L., 2 Dryer(Duplex air dryer with co and dew ponit monitor, capacity should be of 100 CFM), and filtration unit - 5-stage conditioning systems with filters and adsorption dryer and a pressure reducer station,electrical control panel including starter and necessary connections etc.The cabling shall be done from starter panel to the pumps shall be done.The installation must fully comply with the standard EN ISO7396-1/NFPA 99 and the produced air must be for medical use according to<br>the European Pharmacopoeia as per the tech spec.. Each compressor should have minimum FAD of 2534 LPM (89CFM). Third party certification to be produced for medical grade air quality as per europian pharmacopia"<br>
Vacuum Plant
od177308/2020_2021 : "Supply, Installation, Testing and commissioning of Medical grade Triplex Vacuum System must have 3 rotary vane type vacuum pumps(15 HP or higher capacity motor to deliver 4270 ltr capacity) directly driven by motor, a control panel, 2 set of vacuum receivers 3000 Ltr.,secretion Traps and bacteria filters, electrical control panel including starter and necessary connections etc. The cabling shall be done from<br>starter panel to the pumps shall be done. The installation must fully comply with the standard EN ISO7396-1/NFPA 99. each vacuum pumpshould have FAA 4270 LPM at 450mmHg, Third party certification to be produced for Bacteria filters & medical grade vaccum quality. Pump design flow capacity verification shall be done from vendor side."<br>
WAGD SYSTEM
od177856/2020_2021 : Supply, Installation, Testing and commissioning of pendant operated WAGD SYSTEM (meeting ISO 7396-2/HTM02-01) <br>
Area control unit (Area alarm + Area valves)
od177857/2020_2021 : Area Control Unit for 1 Gases (O2) and 1 Vac (DN 20)<br>
od177858/2020_2021 : Area Control Unit for 2 Gases (O2, Air) and 1 Vac (DN 20)<br>
od177861/2020_2021 : Area Control Unit for 5 Gases (O2, Air4,N2O,N, CO2) and 1 Vac <br>
od177862/2020_2021 : Area Control Unit for 6 Gases (O2, Air4, Air 7,N2O,N, CO2) and 1 Vac <br>
Isolation valves
od178023/2020_2021 : Ball Valve, DN 15 - 15x1<br>
od178024/2020_2021 : Ball Valve, DN 20 - 22x1<br>
od178025/2020_2021 : Ball Valve, DN 25 - 28x1,5<br>
od178026/2020_2021 : Ball Valve, DN 32 - 35x1,5<br>
od178027/2020_2021 : Ball Valve, DN 40 - 42x1,5<br>
od178029/2020_2021 : Ball Valve, DN 80 - 76x1,5<br>
od178030/2020_2021 : Ball Valve, DN 100 -108x1,5<br>
Terminal units Wall mounted - BS standard
od178327/2020_2021 : Terminal Unit O2<br>
od178328/2020_2021 : Terminal Unit N2O<br>
od178329/2020_2021 : Terminal Unit Air 400<br>
od178330/2020_2021 : Terminal Unit Air 700<br>
od178335/2020_2021 : Terminal Unit Vac
od178331/2020_2021 : Terminal Unit CO2<br>
od178332/2020_2021 : Terminal Unit N<br>
od178333/2020_2021 : Probes<br>
Bed head panels
od178534/2020_2021 : Horizontal Bed Head Panels of 3 feet long with provision for 3 nos electrical (power & data) & min 3 nos Gas outlets - as per technical specification for beds<br>
od178535/2020_2021 : Horizontal Bed Head Panels of 4 feet long with provision for 3 nos electrical (power & data) & min 5 nos Gas outlets - as per technical specification for beds<br>
od178536/2020_2021 : Continuous Bed head panel with provision for fixing Medical gas outlets, power sockets, nurse cal points etc. as per the design requirement.<br>
Pendants
od178890/2020_2021 : Single Arm ceiling suspended pendant<br>
od178891/2020_2021 : Double Arm ceiling suspended pendant<br>
Medical Equipments
od178893/2020_2021 : Supply, installation, testing and commissioning of Twin Oxygen Flow meter with humidifier bottle at one end and nebulisation adaptor at other end. Matching probe / adaptor shall be provided at both ends.<br>
od178894/2020_2021 : Supply, installation, testing and commissioning of Ward Suction Unit with 1200 ml suction jar with vaccum regulator and vaccum line filter as per specifications. Matching ss probe / adaptor shall be provided at one end suitable for Vacuum Gas outlets and other end for Vacuum Hose<br>
Master plant alarm
od178898/2020_2021 : Master plant alarm<br>
Copper Piping As per EN13348 standards.
od178899/2020_2021 : 12mm<br>
od178900/2020_2021 : 15mm<br>
od178901/2020_2021 : 22mm<br>
od178902/2020_2021 : 28mm<br>
od178903/2020_2021 : 35mm<br>
od178904/2020_2021 : 42mm<br>
od178905/2020_2021 : 54mm<br>
od178906/2020_2021 : 76mm<br>
od178907/2020_2021 : 108 mm<br>
RO PLANT
od195749/2020_2021 : SITC of Microprocessor based control panel with control wiring and interlocks<br>between equipment, with all accessories, complete as required for the full<br>system.<br>Lumpsum<br><br>(Note: Power cabling upto the control panel as required will be provided by<br>othes Agencies)
od195750/2020_2021 : SITC of No return valve of 25mm dia
od195751/2020_2021 : SITC of Y strainer of 25mm dia
od195754/2020_2021 : SITC of Level SwitchesMagnetic Type Level switch.
od195755/2020_2021 : SITC of e) Pressure Switch :Seamless Bellow type Pressure<br>switch.<br>
od195756/2020_2021 : SITC of Conductivity Indicator (CI) :Conductivity Sensor/Indicator.<br>On-Line Sensor.<br>
od195757/2020_2021 : SITC of c) RotametersAcrylic Rotameter.<br>Minimum 1.5 times the feed flow.<br>
od195758/2020_2021 : SITC of Centrifugal monobloc RO water circulation pumps with all accessories,<br>motors and starters.<br>Note :<br>Pump head, motor and starter shall be as per actual requirement<br>b) For circulation from Storage Tanks and Other Medical Equipment<br>i) Flow : 840 LPH<br>ii) Head : 25 Mt<br>
od195759/2020_2021 : SITC of Centrifugal monobloc RO water circulation pumps with all accessories,<br>motors and starters.<br>Note :<br>Pump head, motor and starter shall be as per actual requirement<br>a) For circulation from Storage Tank to Dialysis Machines<br>i) Flow : 336 LPH<br>ii) Head : 25 Mt<br>
od195760/2020_2021 : SITC of Fabricated RO water storage tanks of capacity indicated below, veritcal<br>cylindrical, made out of full stianless steel (SS 316) and of thickness<br>5mm for shell and 8mm for dished ends, with inlet/ outlet/ overflow/ drain/<br>vent connections, stainless steel valves/fittings, 450 mm dia manhole with<br>bolted cover, capacity / safety controls, control panels, complete in all<br>respects.<br>b) 4000 Litres Capacity for Other Mecial Equipment listed in Clause 2.4.1 of<br>the technical specifications (size 1600 mm dia and 2200 mm height).<br><br>
od195761/2020_2021 : SITC of Fabricated RO water storage tanks of capacity indicated below, veritcal<br>cylindrical, made out of full stianless steel (SS 316) and of thickness<br>5mm for shell and 8mm for dished ends, with inlet/ outlet/ overflow/ drain/<br>vent connections, stainless steel valves/fittings, 450 mm dia manhole with<br>bolted cover, capacity / safety controls, control panels, complete in all<br>respects.<br>a) 5000 Litres Capacity for Dialysis Machines listed in Clause 2.4.1 of the<br>technical specifications (size 1800 mm dia and 2200 mm height)<br>
od195762/2020_2021 : SITC of UV system (Post)
od195763/2020_2021 : SITC of Post Chlorination System:<br>.Quantity : One<br>Type : Positive Displacement Pump<br>Flow Range : 0.2 to 4 LPH<br>Max. Working Pressure : 3.5 kg / cm2<br>MOC of Dosing Tank : SS 304<br>Low Level Switch : Shall be provided<br>.<br><br>
od195764/2020_2021 : SITC of pH Correction SystemQuantity : One<br>Type : Positive Displacement Pump<br>Flow Range : 0.2 to 4 LPH<br>Max. Working Pressure : 3.5 kg / cm2<br>MOC of Dosing Tank : SS 304<br>Low Level Switch <br>
od195765/2020_2021 : SITC of R.O.Plant (including housing, Feed pump, membrane and accessories)No. of Housing : 2<br>Purpose : To pack membranes and operate<br>Maximum Flow rate : 3000 LPH <br>Material of Construction : Stainless Steel 316<br>Operating Pressure : 20 Kg/cm2 (or higher if required)<br>Position : Horizontal<br><br>
od195766/2020_2021 : SITC of R.O.High Pressure Pumps (3000 LPH flow, 20.0 kg/cm2 discharge<br>pressure or as required)Type of Pump : Vertical Multistage Pump ,Maximum Flowrate : 2700 LPH ,Operating Pressure : 20.0 kg/cm2 ,Material of Construction :Twon SS 316<br>
od195767/2020_2021 : SITC of Catridge Filter 1No. of Unit :<br>Type of Cartridge :<br>Rating :<br>Flow Rate :<br>Feed Water Turbidity :<br>No. of Cartridge :<br>MOC of Housing :<br>One<br>PP Spun bonded type<br>5 micron<br>3000 LPH.<br>5 NTU<br>2 Nos. 500 mm long x 100mm dia.<br>(shall be indicated by the<br>Tenderer)<br>SS 316.<br>
od195768/2020_2021 : Acid Dosing System:Quantity : One<br><br>Type : Positive Displacement Pump<br>Flow Range : 0.2 to 4 LPH<br>Max. Working Pressure : 3.5 kg / cm2<br>MOC of Dosing Tank : SS 304.<br><br><br>
od195771/2020_2021 : Supply, Installation, Testin & Commissioning of Antiscalent Dosing System-Quantity :<br>Type :<br>Flow Range :<br>Max. Working Pressure :<br>MOC of Dosing Tank :<br>Low Level Switch :<br>One<br>Positive Displacement Pump<br>0.2 to 4 LPH<br>3.5 kg / cm2<br>HDPE – 100 Litres.<br>
od196027/2020_2021 : Supply, Installation, Testing & Commissioning Iron Removal Filter-Quantity :<br>No. of Unit - One<br>Type - Vertical Down flow<br>Flow Rate - 3000 LPH<br>Max. Operating Pressure - 3.5 kg/cm2<br>Pressure Drope at Flow - 0.5 kg/cm2<br>Test Pressure - 5.0 kg/cm2<br>Dimensions - Shall be indicated by the Tenderer<br>Time for Backwash - 5 –10 mins<br>Filter Media - MnO2 granuels supported on silex media.<br>Pipe Size - 25 mm NB<br>Flange Standard - As per BS 10 Table `E`<br>Pipe Class & Standard - I.S. 1239 `B` Class.<br>Valve Type - CI Diaphragm Valve.<br>Pressure Gauges - 75 mm dial<br>Internal Lining - Two coats of food grade epoxy paint.<br>External Paint - Two Coats of synthetic enamel paint.<br>
od196046/2020_2021 : Stainless steel (SS 316L) seamless tube piping conforming to ASTM,<br>A213 standards and valves/strainers with stainless dteel (SS 316) body<br>and impeller, from pre-treated water connection flange to the final<br>connection to various equipment listed in Clause 2.4.1 of the technical<br>specifications<br>Piping - 25 mm dia.
od196047/2020_2021 : Stainless steel (SS 316L) seamless tube piping conforming to ASTM,<br>A213 standards and valves/strainers with stainless dteel (SS 316) body<br>and impeller, from pre-treated water connection flange to the final<br>connection to various equipment listed in Clause 2.4.1 of the technical<br>specifications<br>Piping - 40 mm dia.
od196048/2020_2021 : Stainless steel (SS 316L) seamless tube piping conforming to ASTM,<br>A213 standards and valves/strainers with stainless dteel (SS 316) body<br>and impeller, from pre-treated water connection flange to the final<br>connection to various equipment listed in Clause 2.4.1 of the technical<br>specifications<br>Piping<br>50 mm dia.
od196055/2020_2021 : Stainless steel (SS 316L) seamless tube piping conforming to ASTM,<br>A213 standards and valves/strainers with stainless dteel (SS 316) body<br>and impeller, from pre-treated water connection flange to the final<br>connection to various equipment listed in Clause 2.4.1 of the technical<br>specifications<br>Piping<br>12 mm dia.
od196080/2020_2021 : Supply, Installation and Commissioning of Isolation Ball Valve - SS 31<br>40 mm dia.
od196081/2020_2021 : Supply, Installation and Commissioning of Isolation Ball Valve - SS 31<br>12 mm dia.
od196082/2020_2021 : Supply, Installation and Commissioning of Isolation Ball Valve - SS 31<br>25 mm dia.
od196083/2020_2021 : Supply, Installation and Commissioning of Isolation Ball Valve - SS 31<br>50 mm dia.
SEWAGE TREATMENT PLANT
od91209/2020_2021 : Supply, Installation, Testing & Commissioning of Fine Screen for sullage.MoC: SS 304, Bucket Type Screen, Frame in 1” Square Pipe and Perforated Sheet with 6 mm Spacing with suitable facility to remove trapped materials.<br>
od91210/2020_2021 : Supply, Installation, Testing & Commissioning of Coarse Screen for sewage.MoC: SS 304, Angle of Inclination – 45 deg, Frame in 1” Square Pipe and Bars made of 10 mm Square Pipe with 12 mm Spacing with suitable facility to remove trapped materials.<br>
od91312/2020_2021 : Supply, Installation, Testing & Commissioning of plumbing interconnections considering a plant room with in 5 m nearby STP.Airline Header: GI/MS, Air line after header UPVC-ASTM, Pressurized Water & Wastewater lines - UPVC-ASTM, Overflow Conduits / Gravity Lines – PVC 10 kg/cm2, Ball Valves - UPVC, Gate & Globe Valves – Brass,Slotted Chanel & Rod – GI<br>
od91313/2020_2021 : "Supply, Installation, Testing & Commissioning of Electrical Cables considering a plant room with in 5 m nearby STP.Cables of approved make 4Core 10 mm2, Aluminium Armored Cable, 2.5 mm2- Flexible Cu Cable, 1.5 mm2-Cu CableFlexible"<br>
od91314/2020_2021 : Supply, Installation, Testing & Commissioning of Electrical control panel: Manual operation.All Switch gear- MCB, OLR, Single Phase Preventer, H/L Protection, Volt meter, Push Button, Indication Lamp ,TOD energy meter, flow meter etc of approved Make for Level based On-off Control Valves provided with float switch etc.<br>
od91315/2020_2021 : "Supply, Installation, Testing & Commissioning of Activated Carbon Filter.Working Pressure : 2.5 - 3.0 Bar, MoC: MS, Flow Rate: 15 m3/hr, Media Type: Activated Carbon – IV 900, Diameter – 1.2 Meter, Height -1.8 Meter Process Connection - T&B, Valve type: manual valve -2"", with Inlet & Outlet Pressure monitoring, Hand Valves and all required accessories etc. Complete"<br>
od91316/2020_2021 : "Supply, Installation, Testing & Commissioning of Pressure Sand Filter ,Working Pressure : 2.5 - 3.0 Bar, MoC: MS, Flow Rate: 15 m3/hr, Media Type: Sand & Pebbles, Diameter – 1.2 Meter, Height -1.8 Meter Process Connection - T&B, Valve type: manual valve -2"", with Inlet & Outlet Pressure monitoring, Hand Valves and all required accessories etc. Complete"<br>
od91317/2020_2021 : Supply, Installation, Testing & Commissioning of Filter Feed Pumps.MoC: Cast Iron, Duty: Continuous, Packing: Mechanical Seal, with a Flow Rate of min 300 LPM or above at a Head >25 m In a configuration of 1 Working & 1 Standby, Power- 5 HP, with Outlet Pressure monitoring, Strainers, Recirculation Valves, Check Valves & all required accessories etc. Complete<br>
od91319/2020_2021 : Supply, Providing in Position, Testing & Commissioning of Anaerobic Bio media in up flow anaerobic tank.Minimum Specific Surface Area of 150 m2/m3, MoC: PVC, Type –Corrugated Sheets <br>
od91320/2020_2021 : Supply, Installation, Testing & Commissioning of Electronic metering pumps,Diaphragm Type Electronic Dosing Pump, MoC: PP, Foot Valve, Suction/Discharge LDPE Tubing, Strokes: Manually Regulated, Pressure: 0.0-3.5 kg/cm2, PE Storage Tank - 100 L and all accessories complete.<br>
od91321/2020_2021 : Supply, Providing in Position, Testing & Commissioning of Aerobic Bio media for MBBR Tank. Minimum Specific Surface Area of 500 m2/m3, Voidage - 95%, MoC: Virgin PE (Preferably Imported), Type - Cylindrical,Size: 25mm X 12mm<br>
od91322/2020_2021 : Supply, Installation, Testing &Commissioning of Twin Lobe Blower with Motor.Continuous Duty, Operating Discharge of 300 m3/hr or above, with differential Pressure of 4 m WC, With three phase Motors with Power: 10 HP, pulley fixed on a frame with Inlet / Outlet Silencers and Header Piping as required in MSEP, in a configuration of 1 Working & 1 Standby, also with Outlet Pressure monitoring, Pressure Relief Valves, Check Valves, Hand Valves & all required accessories etc. Complete.<br>
od91323/2020_2021 : Supply, Providing in Position, Testing & Commissioning of tube settler media in secondary settling tank.Minimum Specific (1.1mm thick PVC of unequal hexagonal chevron shape)<br>
od91324/2020_2021 : Supply, Installation, Testing & Commissioning of Aeration Grid with Fine Bubble Diffusers in MBBR tank.Disc or Tube Type Fine Bubble Diffusers with Design Flow rate of 3-5 m3/hr with EPDM membrane construction, 16 Nos with associated Pipe work in MSEP up to Main Header and uPVC ASTM Sch 40 Pipe for Wetted Parts for Aeration Grid as required for achieving uniform aeration.<br>
od91325/2020_2021 : Supply, Installation, Testing & CommissDisc or Tube Type Coarse Bubble Diffusers with Design Flow rate of 10 m3/hr with EPDM membrane construction, 24 Nos with associated Pipe work in MSEP up to Main Header and uPVC ASTM Sch 40 Pipe for Wetted Parts for Aeration Grid as required in Collection tanks, Equalization tank, Chemical precipitation tank etc.ioning of Aeration Grid with Coarse Bubble Diffusers.<br>
od166872/2021_2022 : Supply, Installation, Testing & Commissioning of Ultra-Filtration Plant- Incl. Skid, Dosing Pumps, Solenoid Valve based Operation and PLC based Control, Capacity - 10 m3/hr, with Low Pressure Membrane, Flux Rate for Design – 200 LMH, Pressure Vessel rating10 Bar, with Feed Pumps (1 Working+ 1 Standby), Backwash Pumps (1 Working), CIP Pump in SS 304 Construction (1 Working), 20” Jumbo Cartridge Filters in the Inlet and in CIP Inlet Lines, Dosing Arrangements, Chemical Tank, Check Valves, Hand Valves, Pressure Guages, Rotameters for Flow Monitoring etc Complete with all electrical and plumbing works
od91326/2020_2021 : Supply, Installation, Testing & Commissioning of Raw Sewage & Sullage transfer pump,Submersible Sewage Transfer & Sullage Transfer Pumps (cutter pump), Continuous Duty, Minimum Discharge of 200 LPM, or above, with 10 m Head, three phase with Power: 2.0 HP,in a configuration of 1 Working & 1 Standby, with Outlet Pressure monitoring, Strainers, Recirculation Valves, Check Valves & all required accessories etc. Complete<br>
od91335/2020_2021 : Supply, Installation, Testing & Commissioning of Sludge Transfer Pump & Sludge recirculation pump.Non Clog Self Priming Type with back pull out design, MoC: CI, Packing - Non asbestos PTFE gland, Capacity 10 m3/Hr, Head - 10 m, Power- 1.0 HP, in a configuration of 1 Working each with No Standby<br>
WATER TREATMENT PLANT
od91477/2020_2021 : Supply, Installation, Testing & Commissioning of Electrical Cables considering a plant room with in 5 m nearby Water Tank.Cables of approved make 4Core 10 mm2, Aluminium Armored Cable, 2.5 mm2- Flexible Cu Cable, 1.5 mm2-Cu CableFlexible<br>
od91478/2020_2021 : "Supply, Installation, Testing & Commissioning of Activated Carbon Filter, Working Pressure : 2.5 - 3.0 Bar, MoC: MS, Flow Rate: 15 m3/hr, Media Type: Activated Carbon – IV 1200, Diameter – 1.2 Meter, Height -1.8 Meter Process Connection - T&B, Valve type: manual valve -2"", with Inlet & Outlet Pressure monitoring, Hand Valves and all required accessories etc. Complete"<br>
od91479/2020_2021 : "Supply, Installation, Testing & Commissioning of Pressure Sand Filter ,Working Pressure : 2.5 - 3.0 Bar, MoC: MS, Flow Rate: 15 m3/hr, Media Type: Sand & Pebbles, Diameter – 1.2 Meter, Height -1.8 Meter Process Connection - T&B, Valve type: manual valve -2"", with Inlet & Outlet Pressure monitoring, Hand Valves and all required accessories etc. Complete"<br>
od91480/2020_2021 : Supply, Installation, Testing & Commissioning of Filter Feed Pumps MoC: Cast Iron, Duty: Continuous, Packing: Mechanical Seal, with a Flow Rate of min 300 LPM or above at a Head >25 m In a configuration of 1 Working & 1 Standby, Power- 5 HP, with Outlet Pressure monitoring, Strainers, Recirculation Valves, Check Valves & all required accessories etc. Complete<br>
od91481/2020_2021 : Supply, Installation, Testing & Commissioning of Electronic metering pumps Diaphragm Type Electronic Dosing Pump, MoC: PP, Foot Valve, Suction/Discharge LDPE Tubing, Strokes: Manually Regulated, Pressure: 0.0-3.5 kg/cm2, PE Storage Tank - 100 L and all accessories complete<br>
od91484/2020_2021 : Supply, Installation, Testing & Commissioning of Electrical control panel: Manual operation, All Switch gear- MCB, OLR, Single Phase Preventer, H/L Protection, Volt meter, Push Button, Indication Lamp, flow meter etc of approved Make for Level based On-off Control Valves provided with float switch etc.<br>
od91485/2020_2021 : "Supply, Installation, Testing & Commissioning of plumbing interconnections considering a plant room with in 5 m nearby Water Tank.Water lines - UPVC-ASTM, Ball Valves - UPVC, Gate & Globe Valves – Brass, Slotted Chanel & Rod – GI"<br>
od350081/2021_2022 : Supply, Installation, Testing & Commissioning of Ultra-Filtration Plant- Incl. Skid, Dosing Pumps, Solenoid Valve based Operation and PLC based Control, Capacity - 15 m3/hr, with Low Pressure Membrane, Flux Rate for Design – 200 LMH, Pressure Vessel rating 10 Bar, with Feed Pumps (1 Working+ 1 Standby), Backwash Pumps (1 Working), CIP Pump in SS 304 Construction (1 Working), 20” Jumbo Cartridge Filters in the Inlet and in CIP Inlet Lines, Dosing Arrangements, Chemical Tank, Check Valves, Hand Valves, Pressure Guages, Rotameters for Flow Monitoring etc Complete with all electrical and plumbing works. ( after WTP treatment ).
Bio Gas Plant
od81283/2020_2021 : Supply, installation, testing and commissioning of 45cum Bio gas plant. 1no. waste crusher 3HP, 2800rpm, 3 phase electric motor with all accessories having a capacity of 250kg/hr, with DOL starter and overload protection followed by Slurry collection tank (2x1.2x1.2m). <br>Cost includes:<br>SIte clearing, excavation of plant, manufacturing of sludge layer chamber, manufacturing of fermentation chamber, manufacturing of gas storage and gas collecting chamber, manufacturing of fermentation chamber pocket, coating of paint inside dome, manufacturing of hydraulic chamber and manufacturing of 1 inlet chamber with cast iron cover. Fixing of 1 no. 10" PVC pipe, laying of gas pipe line and supplying of 24cft Biogas burner (Industrial) - 5 nos.<br>It includes commissioning charges
od253506/2021_2022 : Supply of 60L Colour coded bins of Various shades
od253507/2021_2022 : Supply of 120 L Bio Bins
Operation Theatre
od261984/2022_2023 : Supply installation testing and commissioning of wall panels, ceiling panels, doors, scrub units, sink, storage cabinets, lighting system, x-ray view box, writing boards, laminar air flow system, flooring, Multi function panels, pass box etc for OT complex consisting of 12 Nos of OT and its ancillary facilities. See Annexure A - OT Technical Specification for detailed item wise specification and quantity of the above items (item no: 1 to12). The rate shall be quoted per OT & its ancillary facilities.
od261985/2022_2023 : Supply & installation of Celling Mounted Surgical Double Dome LED OT light with Integrated Camera System ,and third arm to mount including medical display 21’’ or more including supply of the display unit. (See Annexure A - OT Technical specification)<br>
od261986/2022_2023 : Supply installation testing and commissioning of OT pendant (surgeon). See Annexure A - OT Technical Specification for detailed quantity split up and specification.
od261987/2022_2023 : Supply installation testing and commissioning of OT pendant (Anesthesia). See Annexure A - OT Technical Specification for detailed quantity split up and specification.
od261988/2022_2023 : Supply & installation of Medical Grade Monitor / OR Integration Display for each OT (See Annexure A - OT Technical specification)
od261989/2022_2023 : Supply & installation of Ceiling Supply Unit for mounting Display system for OR Integration (Spring-loaded Arm/ Arm Type) (See Annexure A - OT Technical specification) • Should be able to fix two monitors in the single pendent.
PV SOLAR SYSTEM
DSR ITEMS
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
MARKET RATE ITEMS
od81305/2020_2021 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx35sq.mm Al Cable
od81306/2020_2021 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx400sq.mm Al Cable
od81307/2020_2021 : Supply, installation, testing and commissioning of 395Wp Monocrystalline PERC Solar Photovoltaic Panels with framed 72 solar cells per module, IP68 rated junction box and IP68 rated connectors. The panel shall comply to latest IEC standards 61215/ 61730/ UL-1703/ IEC 61701/ IEC 62716. (Make: WAAREE - ARKA Series WSM 395 or equivalent)
od81569/2020_2021 : Supply of superior quality tubular cable socket and making termination of following cable size including crimping etc. as required<br>4 Sq. mm.
od81570/2020_2021 : DC Cabling & Termination<br>Supply, laying, testing and commissioning of tinned Cu flexible conductor, having cross linked halogen free, flame retardant compound with UV reistant insulation, 1.5 kV DC nominal voltage solar cable. Identification - Red & Black. IEC 60228 Class 5.<br>4 Sq. mm.
od81571/2020_2021 : SOLAR PHOTOVOLATIC INVERTERS<br>Supply, installation, testing and commissioning three phase string inverters of AC Output Power 50kW, comprising of 10-16 input pair connections, fuses, DC switch, surge arresters type II on DC side and AC switch, surge arrester type 2, terminal blocks on AC. Operating DC voltage of 300V-900V The inverter shall be provided with an IP 42 enclosure suitable for working with ambient temperature of 50°. Complies with the IEC standards (make: ABB model: TRIO-50.0-TL-OUTD or equivalent).
od81588/2020_2021 : Supply, Installation, Testing and Comissioning of pluggable type surge arrester in suitable enclosure Class B+C/ Class 1+2 as per IEC 61643 (IP 20) with potential free contact, thermal dis connector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number arrester Spark Gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E) . Lightning Impulse Current - 37.5 kA (10/350µ sec) for Line to Neutral & 25 kA(10/350µ sec) for Neutral to Earth,Nominal discharge current-30 kA (8/20µ sec) for Line to Neutral & 40 kA(8/20µ sec) for Neutral to Earth, max discharge current 150 kA (8/20µ sec) for Line to Neutral & 50 kA(8/20µ sec) for Neutral to Earth. Voltage protection level 1300V (L to N) & 1200V (N to E). Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E) DIN rail mounting type etc complete with back up fuse, including all accessories and connections as required and as directed.
od81589/2020_2021 : Supply, Installation, Testing and Comissioning of type 2 surge arrester for PV system. Error-resistant Y circuit for use according to VDE 0100-712 (EN 50539-12). Surge protection equipotential bonding to VDE 0100-443 (IEC 60364-4-44). Arresting capacity to 40 kA (8/20) per pole. Low DC protection level: < 2.6 kV (Voc max = 600 V DC). Arrestor, connectable with thermodynamic cut-off unit and visual function display Encapsulated, zinc oxide varistor arrestor for use in distributor housings including all accessories and connections as required and as directed.
od81590/2020_2021 : Supply and Installation of outdoor enclosure with open able door made of Thermoplastic Glass Fiber Reinforced Polycarbonate (PC) with an Ingress Protection IP 65 in accordance with IEC 60529. The box shall have hinged door/cover with pre punched / knock out for cable entry in all the four sides as well as on the back side. It shall be suitable to perform under ambient temperature for PS -25 degC up to +40 degC & PC -35 degC up to +80 degC & should be able to resist temperature up to +130 degC. The enclosure shall be halogen & silicon free, UV resistant, fire retardant & self-extinguishing, the combustion behavior shall be in accordance with VDE 0471 / UL 94 for 960degC. The enclosures shall have the minimum dimensions as below:<br>250 x 370 x 122 mm (Min 24 module)
od81591/2020_2021 : Supply and Installation of outdoor enclosure with open able door made of Thermoplastic Glass Fiber Reinforced Polycarbonate (PC) with an Ingress Protection IP 65 in accordance with IEC 60529. The box shall have hinged door/cover with pre punched / knock out for cable entry in all the four sides as well as on the back side. It shall be suitable to perform under ambient temperature for PS -25 degC up to +40 degC & PC -35 degC up to +80 degC & should be able to resist temperature up to +130 degC. The enclosure shall be halogen & silicon free, UV resistant, fire retardant & self-extinguishing, the combustion behavior shall be in accordance with VDE 0471 / UL 94 for 960degC. The enclosures shall have the minimum dimensions as below:<br>250 x 200 x 122 mm (Min 12 module)
od81592/2020_2021 : Copper MC Connectors for solar panels with silver coated, bush bakelite with lock provision for both male and female for positive and negative as a set for each solar panel
od81655/2020_2021 : DC MCB<br>Supplying and fixing of 20 A, Double pole, 250V, 6 kA, DC miniature circuit breaker suitable for PV systems to be mounted in existing DCDB complete with connections, testing and commissioning etc. as required.
od81670/2020_2021 : Solar Meter<br>Supply, Installation, Testing and Commissioning of 3 phase Bidirectional meter of accuracy class 1 with necessary CT and accessories including making all connections as required.<br>
od81671/2020_2021 : Supply, fixing, testing and commisioning of following rating, breaking capacity and pole, type thermal magnetic based MCCB in existing ACDB with spreader links, terminal connections and all accesories as required making all necessary connections etc as required and instructed by engineer in charge/consultant.<br>80Amp 16kA FP MCCB with Thermal-Magnetic Release
od306751/2020_2021 : Supply and laying the following sizes of strips on cable tray/wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant. <br>Copper wire No.8 SWG
MOUNTING STRUCTURE
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
CCTV SYSTEM
od188785/2020_2021 : Supply, Installation, testing and commissioning of IR Fixed Dome Camera with below specifications as minimum and with all the necessary accessories for the installation<br> - 3.6 mm fixed lens<br> - 2MP Resolution<br> - H.264, MJPEG codec<br> - Edge Storage (Minimum 32GB)<br> - IR - 30 meters<br> - 120dB WDR<br> - IK10, IP66<br> - PoE
od188786/2020_2021 : Supply, Installation, testing and commissioning of IR Varifocal Dome Camera with below specifications as minimum and with all the necessary accessories for the installation<br> - 3.2~10mm Varifocal Lens<br> - 2MP Resolution<br> - H.265, H.264 Codec<br> - Edge Storage (Minimum 32 GB)<br> - IR - 30 Meters<br> - 120dB WDR<br> - IK10<br> - PoE
od188787/2020_2021 : Supply, Installation, testing and commissioning of Indoor type IR Fixed Bullet Camera with below specifications as minimum and with all the necessary accessories for the installation<br> - 3.6mm Fixed Lens<br> - 2MP Resolution<br> - H.265, H.264, MJPEG codec<br> - Edge Storage (Minimum 32GB)<br> - IR - 30 meters<br> - 120dB WDR<br> - IK10, IP66<br> - PoE
od188788/2020_2021 : Supply, Installation, testing and commissioning of outdoor type IR Varifocal Bullet Camera with below specifications as minimum and with all the necessary accessories for the installation<br> - 3.2~10mm Varifocal Lens<br> - 2MP Resolution<br> - H.265, H.264, MJPEG codec<br> - Edge Storage (Minimum 32GB)<br> - IR - 30 meters<br> - 120dB WDR<br> - IK10, IP67<br> - PoE
od188789/2020_2021 : Supply, Installation, testing and commissioning of NVR with below specifications as minimum and with all the necessary accessories for the installation<br> - 128 Channels<br> - Intel Xeon Processor<br> - 8GB Ram or Higher<br> - H.265, H.264, MPEG4, M-JPEG, MxPEG<br> - G. 711, G.726, AAC, Two-Way Audio<br> - Recording Resolution - Up to 20MP<br> - Onvif 2.0 or higher<br> - Storage Capacity - Minimum 120TB<br> - Dual display support<br> - Raid 0,1,5,6<br> - Redundancy Power Supply
od188790/2020_2021 : Supply, installation, testing and commissioning of Video Management System with workstation as per the below specifications as minimum <br> - 256 Camera Licenses (with Future expansion up to 500 cameras)<br> - CPU : Intel® Core® i7-6700<br> - 16GB RAM<br> - Inbuilt Graphics Support of Minimum 4GB<br> - Windows/ Linux<br> - Support for minimum 2HD Displays<br> - 2 x 10/100/1000 Mbps Network Ports<br> - Codecs - H.265/H.264+/ H.264<br> - 2 TB HDD<br> - Keyboard & Mouse
od188791/2020_2021 : Supply, Installation, Testing and Commissioning of LED Displays 43" for CCTV Monitoring with all the necessary wall mounting accessories.
PUBLIC ADDRESS SYSTEM
od188799/2020_2021 : Supply, Installation, Testing & Commissioning of of Horn Speakers with below specifications as minimum and all the necessary accessories<br> - Horn<br> - Rated / Maximum Power - 15/22.5 Watts<br> - IP65
od188800/2020_2021 : Supply, Installation, Testing & Commissioning of of Ceiling Speaker with below specifications as minimum and all the necessary accessories<br> - Ceiling - Metal Grille<br> - Rated / Maximum Power - 6/8 Watts<br> - Taps @ 6/3/1.5 Watts
od188801/2020_2021 : Supply, Installation, Testing & Commissioning of of Cabinet Speaker with below specifications as minimum and all the necessary accessories<br> - wall mounted<br> - Rated / Maximum Power - 6/9 Watts <br> - Sound Pressure level - 96 dB<br> - Taps @ 6/3/1.5 Watts
od188802/2020_2021 : Supply, Installation, Testing & Commissioning of of Power Amplifier with below specifications as minimum and all the necessary accessories<br> - Output Power (RMS)- 120 Watts<br> - Line Inputs - Minimum 2<br> - Outputs - 70 V / 100 V and 8/4 ohm
od188803/2020_2021 : Supply, Installation, Testing & Commissioning of of Power Amplifier with below specifications as minimum and all the necessary accessories<br> - Output Power (RMS)- 240 Watts<br> - Line Inputs - Minimum 2<br> - Outputs - 70 V / 100 V and 8/4 ohm
od188804/2020_2021 : Supply, Installation, Testing & Commissioning of of Power Amplifier with below specifications as minimum and all the necessary accessories<br> - Output Power (RMS)- 480 Watts<br> - Line Inputs - Minimum 2<br> - Outputs - 70 V / 100 V and 8 ohm
od188805/2020_2021 : Supply, Installation, Testing & Commissioning of PA Controller with below specifications as minimum and all the necessary accessories<br> - 6 Zones an expandable up to 18 Zones<br> - BGM Integration/ Provision<br> - Fireman's panel Integration<br> - Playback of Pre Recorded messages of minimum 50<br> - Integration with at least 3 Call stations<br> - Integration with PBX
od188807/2020_2021 : Supply, Installation, Testing & Commissioning of Audio Player with below specifications as minimum and all the necessary accessories<br> - DVD/ CD/ USB
od188808/2020_2021 : Supply, Laying, Testing & Commissioning of Speaker Cable with below specifications as minimum and all the necessary accessories<br> - 2C x 1.5 Sqmm<br> - Unarmored<br> - PVC FRLS
od7420/2021_2022 : Supply, Installation, Testing & Commissioning of router with all required speciifcation details.
ACCESS CONTROL SYSTEM
od189195/2020_2021 : Supply, Installation, Testing & Commissioning of Door Controller with below specifications as minimum and with enclosure, power supply and all the necessary accessories<br> - 2 Door Integration<br> - Onboard TCP/IP Port<br> - 32 Bit Architecture or better<br> - Cardholder - 50,000<br> - Transaction - 40,000<br> - I/Os - 8/4<br> - Readers - 2
od189197/2020_2021 : Supply, Installation, Testing & Commissioning of Standalone Biometric Time & Attendance Machine with below specifications as minimum and all the necessary accessories<br> - Fingerprint Capacity - 3000<br> - Transaction - 1,00,000<br> - Identification Speed - <= 1 Sec<br> - Communication - TCP/IP, USB
od189198/2020_2021 : Supply, Installation, Testing & Commissioning of Mifare cards with below specifications as minimum and all the necessary accessories<br> - Type - Mifare 13.56<br> - Construction - PVC<br> - Transaction Time - <110ms<br> - Memory - 1K
od189199/2020_2021 : Supply, Installation, Testing & Commissioning of Exit Push Button with below specifications as minimum and all the necessary accessories<br> - Type - NO/NC<br> - Materials - Stainless Steel<br> - Suitable GI Backboxe
od189200/2020_2021 : Supply, Installation, Testing & Commissioning of Single Leaf Door Lock with below specifications as minimum and all the necessary accessories<br> - Type - Single Leaf<br> - Holding Force - 600lbs<br> - Inbuilt Magnetic Contact<br> - Anti rust treated for surface<br> - LED Indication for EM Lock status<br> - Including all the mounting brackets
od189201/2020_2021 : Supply, Installation, Testing & Commissioning of Double Leaf Door Lock with below specifications as minimum and all the necessary accessories<br> - Type - Double Leaf<br> - Holding Force - 600lbs<br> - Inbuilt Magnetic Contact for door status monitoring<br> - Anti rust treated for surface<br> - LED Indication for EM Lock status<br> - Including all the mounting brackets
od189202/2020_2021 : Supply, Installation, Testing & Commissioning of Access Control Management & Time and attendance software with below specifications as a minimum and all the necessary licenses<br> - Support for client workstations/ users - Minimum 10 or more<br> - Intrusion System integration<br> - Card Reader Support ( with the proposed entry/ exit readers)<br> - Fingerprnit reader Support ( with the proposed entry/ exit readers)<br> - Minimum number of employee/ user profiles - 1,00,000<br> - Number of reader support - Minimum 300 or higher<br> - Guard Tour System<br> - Maps Integration<br> - Surveillance System Integration - 20 NVRs/ 1200 cameras<br> - Support Client-Server Architecture<br> - Web Support<br> - Time and attendace report<br> - 128 bit AES Data Encrypted communication between the door controllers
od189204/2020_2021 : Supply, Installation, Testing & Commissioning of Workstation for Access Control Management software & Time & Attendance Management Software with below specifications as minimum and all the necessary accessories<br> - Intel i7 Processor<br> - 8GB RAM<br> - 2TB HDD<br> - Windows 10 Pro<br> - MS Office Suite Latest version<br> - 22 Inch Monitor<br> - Keyboard & Mouse
od189205/2020_2021 : Supply, Laying, Testing & Commissioning of 4 Core Multi Stranded Cable for Controller to EM Lock & Contact connection with below specifications as minimum and all the necessary accessories<br> - 4 x 1.0 Sqmm<br> - Unarmored<br> - PVC FRLS<br> - Unshielded
od189206/2020_2021 : Supply, Laying, Testing & Commissioning of 8 Core Multi Stranded Cable for Controller to Reader connection with below specifications as minimum and all the necessary accessories<br> - 8 x 1.0 Sqmm<br> - Unarmored<br> - PVC FRLS<br> - Unshielded
od189207/2020_2021 : Supply, Laying, Testing & Commissioning of 2 Core Multi Stranded Cable for Controller to Exit Switch connection with below specifications as minimum and all the necessary accessories<br> - 2 x 1.0 Sqmm<br> - Unarmored<br> - PVC FRLS<br> - Unshielded
od7427/2021_2022 : Supply, Installation, Testing & Commissioning of IP/ based Biometric & card based access conntrol entry and exit reader with below specifications as minimum and all the necessary accessories<br> - Fingerprint Capacity - 4000 Users and Min 2 template per user<br> - Transaction capacity in device- 50,000 or more<br> - Card - 125Khz/ 13.56Mhz<br> - Identification Speed - <= 1 Sec<br> - Communication - TCP/IP & RS485<br> - Input - Minimum 2 for exit switch and door sensor<br> - Ouput - Minimum 1 for door lock integration
PASSIVE
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
od189655/2020_2021 : Supply, Laying, Testing & Commissioning of CAT6A U/UTP 23 AWG LSZH cable As per EIA/ TIA Standards
od189632/2020_2021 : Supply, Installation, Testing & Commissioning of 24 Port Patch panels CAT6 (1U with rear wire manager) 45˚silver-plated IDCs (insulation displacement connection) for secure, reliable gas-tight connections
od189633/2020_2021 : Supply, Installation, Testing & Commissioning of 24 Port Patch panels CAT6A (1U with rear wire manager) 45˚silver-plated IDCs (insulation displacement connection) for secure, reliable gas-tight connections
od189634/2020_2021 : Supply, Installation,Testing & commissioning of 12 Core Fibre Cable Multi Mode OM3 , armoured
1.19 : Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
od190234/2020_2021 : Supply, Installation, Testing & commissioning of 6 Port LIU, 19" rackmount, with adaptors, Swing-out splice tray in 1U Size. Should have front access for easy splice & patch management. Fully loaded with SC SM Pigtails & adapters for all the cores,
od190235/2020_2021 : Supply, Installation, Testing & commissioning of 12 Port LIU, 19" rackmount, with adaptors, Swing-out splice tray in 1U Size. Should have front access for easy splice & patch management. Fully loaded with SC SM Pigtails & adapters for all the cores.
od189635/2020_2021 : Supply, Installation, Testing & commissioning of 24 Port LIU, 19" rackmount, with adaptors, Swing-out splicetray in 1U Size. Should have front access for easy splice & patch management. Fuly loaded with SC SM Pigtails & adapters for all the cores.
od189636/2020_2021 : Supply, Installation, Testing & commissioning of CAT6 RJ45 I/O with a separator to eliminate crosstalk, Terminates 8 conductors at the same time reducing installation time, 45˚ silver-plated IDCs provide secure, reliable gas-tight connections
od189637/2020_2021 : Supply, Installation, Testing & commissioning of CAT6A RJ45 I/O with a separator to eliminate crosstalk, Terminates 8 conductors at the same time reducing installation time, 45˚ silver-plated IDCs provide secure, reliable gas-tight connections
od189638/2020_2021 : Supply, Installation, Testing & Commissioning of CAT6 Ceiling Connector<br>
od189639/2020_2021 : Supply, Installation, Testing & Commissioning of Single Port Faceplate.<br>
od189640/2020_2021 : Supply, Installation, Testing & Commissioning of Dual Port Faceplate.
1.23.7 : Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.TV antenna socket outlet
od189641/2020_2021 : Supply, Installation, Testing & Commissioning of GI Backbox<br>
od189642/2020_2021 : Supply, Installation, Testing & Commissioning of CAT6 Patch Cord LSZH with Moulded boots Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable.- 1 Meter
od189643/2020_2021 : Supply, Installation, Testing & Commissioning of CAT6 Patch Cord LSZH with Moulded boots, Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable - 2 Meter
od189644/2020_2021 : Supply, Installation, Testing & Commissioning of CAT6A Patch Cord LSZH with Moulded boots Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable - 1 Meter
od189645/2020_2021 : Supply, Installation, Testing & Commissioning of CAT6A Patch Cord LSZH with Moulded boots Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable.- 2 Meter
od189646/2020_2021 : Supply, Installation, Testing & commissioning of Fibre optic patch cords LSZH SM(SC to LC PC) - 50/125 - 1 Meter
od189647/2020_2021 : Supply, Installation, Testing & Commissioning of 15U Network Rack with below specifications as minimum and all the necessary accessories<br> - Height - 15U<br> - Dimensions - 600 x 600<br> - Fan Units with 4 Fans<br> - PDU 6 point - 1 Nos's<br> - Mounting Hardware Kit (1 lot)<br> - Tray<br> - Front glass doors and back steel door and side panels
od189648/2020_2021 : Supply, Installation, Testing & Commissioning of 18U Network Rack with below specifications as minimum and all the necessary accessories<br> - Height - 18U<br> - Dimensions - 600 x 600<br> - Fan Units with 4 Fans<br> - PDU 6 point 5 Amps<br> - Mounting Hardware Kit (1 lot)<br> - Tray<br>- Front glass doors and back steel door and side panels
od189649/2020_2021 : Supply, Installation, Testing & Commissioning of 27U Network Rack with below specifications as minimum and all the necessary accessories<br> - Height - 27U<br> - Dimensions - 600 x 800<br> - Fan Units with 4 Fans<br> - PDU 6 point 5 Amps<br> - Mounting Hardware Kit (1 lot)<br> - Tray<br>- Front glass doors and back steel door and side panels
od189650/2020_2021 : Supply, Installation, Testing & Commissioning of 42U Network Rack with below specifications as minimum and all the necessary accessories<br> - Height - 42U<br> - Dimensions - 800 x 1000<br> - Fan Units with 4 Fans<br> - PDU 10 point 5 Amps x 2 No's<br> - Mounting Hardware Kit (2 lot)<br> - Tray<br> - Front glass doors and back steel door and side panels
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
od189651/2020_2021 : Supply, Laying, Testing & Commissioning of GI Perforated Cable Tray with 300x60 thickness with cover
od189652/2020_2021 : Supply, Laying, Testing & Commissioning of GI Perforated Cable Tray with 200x60 thickness with cover
od189653/2020_2021 : Supply, Laying, Testing & Commissioning of GI Perforated Cable Tray with 150x60 thickness with cover
od7435/2021_2022 : Supply, Installation,Testing & commissioning of Intelligent Controllers Solution with necessery software for monitoring all the CAT6A ports status, health etc.
DATA - ACTIVE
od190174/2020_2021 : Supply, Installation, Testing & Commissioning of 24 Port Layer -2 Network Switch 10/100/1000 Mbps with 2 SFP slots minimum loaded with 10G Uplink
od190175/2020_2021 : Supply, Installation, Testing & Commissioning of 48 Port Layer -2 Network Switch 10/100/1000 Mbps with 2 SFP slots minimum loaded with 10G Uplink
od190176/2020_2021 : Supply, Installation, Testing & Commissioning of 24 PoE Layer -2 Port Network Switch 10/100/1000 Mbps with 2 SFP slots minimum loaded with 10G Uplink.
od190177/2020_2021 : Supply, Installation, Testing & Commissioning of 48 PoE Layer -2 Port Network Switch 10/100/1000 Mbps with 2 SFP slots minimum loaded with 10G Uplink
od190178/2020_2021 : Supply, Installation, Testing & Commissioning of 48 Port Layer - 3 Fiber switch populated with Modules.
od190179/2020_2021 : Supply, Installation, Testing & Commissioning of 10G SM SFP Modules.
od190180/2020_2021 : Supply, Installation, Testing & Commissioning of Indoor Dual Band Wi-Fi Access Point<br> - Indoor Ceiling Mount Type<br> - Dual radio (2.4/5 GHz) 802.11a/b/g/n/ac<br> - Wave2 2x2 MU-MIMO (2SS)<br> - 802.3af 1000Base-T PoE port<br> - Minimum 18 dBm for 2.4 GHz/5 GHz output power <br> - All the required ceiling mount accessories
od190181/2020_2021 : Supply, Installation, Testing & Commissioning of Wireless Controller with below specifications as minimum and with all the necessary accessories for the installation.<br> - Rack mountable<br> - Min 2 x SFP+ ports<br> - Min 4 x 1000 Base T ports<br> - 4 x 1000 Base-X SFP Ports<br> - Minimum 5000 concurrent devices<br> - Wireless Access Point licenses for minimum 210 APs and scalability up to minimum 250 APs
od190182/2020_2021 : Supply, Installation, Testing & Commissioning of UTM with below specifications as minimum and with all the necessary accessories for the installation.<br>- Firewall & VPN<br> - IPS, URL and application control<br> - Anti Virus, Anti Malware & Spam Control,Etc<br> - Inbuilt storage of min 500GB in RAID 1<br> - Memory should - 8Gn or higher<br> - Throughput capacity minimum - 10 Gbps<br> - Threat Prevention throughput - 1Gbps<br> - Appliance should support minimum 1,500,000 concurrent sessions<br> - Ports - 4x 10/100/1000Base-T & 2 x 1000B SFP ports
TELEPHONY
od190183/2020_2021 : Supply , Installation of IPPBX System with below features and accessories<br>- 2 PRI Ports<br>- 8 SIP Trunk license<br>- Analog Extensions 400<br>- IP Extension - 50<br>- Digital Extension - 200<br>- Multiple Paging Options for announcement in PA
od190184/2020_2021 : Supply, Installation, Testing & Commissioning of User Phone
od7439/2021_2022 : Supply, Installation, Testing & Commissioning of IP Phone
od7440/2021_2022 : Supply, Laying, Testing & Commissioning of 300 Pair Armored Multipair cable with all the accssories required to complete the system
od7441/2021_2022 : Supply, Laying, Testing & Commissioning of 10 Pair Krone Module with rack mount and all the accssories required to complete the system
od7442/2021_2022 : Supply, Laying, Testing & Commissioning of 20 Pair Krone Module with rack mount and all the accssories required to complete the system
od7443/2021_2022 : Supply, Laying, Testing & Commissioning of 50 Pair Krone Module with rack mount and all the accssories required to complete the system
od7444/2021_2022 : Supply, Laying, Testing & Commissioning of 100 Pair Krone Module with rack mount and all the accssories required to complete the system
od7445/2021_2022 : Supply, Laying, Testing & Commissioning of 600 Pair Krone Module with rack mount and all the accssories required to complete the system
AV SYSTEM
od190187/2020_2021 : Supply, Installation, Testing and commissioning of UHF Wireless Handheld Microphone with Receiver - 30mw Power Output,
od190189/2020_2021 : Supply, Installation, Testing and commissioning of 94" Motorized Projection screen with built-in Low Voltage Controller and Minimum black of 350 mm.
od190190/2020_2021 : Supply, Installation, Testing and commissioning of 3300 lumens projector WXGA, 3LCD projector, 0.46:1 Throw, HDMI X 1, VGA X 2, Video IN X 1, Monitor OUT X 1, RS232 IN X 1, LAN X 1, USB A X 1, USB B X 1, Audio IN X 2, Audio OUT X 2,
od190191/2020_2021 : Supply, Installation, Testing and commissioning of HDMI Audio De-Embedder.
od190194/2020_2021 : Supply, Installation, Testing and commissioning of HDMI Cat5e Box Type transmitter runs up to 70 mtr.
od190195/2020_2021 : Supply, Installation, Testing and commissioning of HDMI Cat5e Box Type receiver runs up to 70 mtr.
od7450/2021_2022 : Supply, Installation, Testing and commissioning of 4" Ceiling speaker with 6W@8Ohm with necessary mounting bracket
od7451/2021_2022 : Supply, Installation, Testing and commissioning of 4" ceiling speaker with 12W@70/100V with necessary mounting bracket.
od7452/2021_2022 : Supply, Installation, Testing and commissioning of wall mount speaker with minmum 6W@70V/ 100V
od7453/2021_2022 : Supply, Installation, Testing and commissioning of 2 Channel amplifier with 40W@8 or 4 Ohm
od7454/2021_2022 : Supply, Installation, Testing and commissioning of 2 Channel amplifier with 120W@8 or 4 Ohm
od7455/2021_2022 : Supply, Installation, Testing and commissioning of 2 Channel Mixer Amplifier with required acessories
od7456/2021_2022 : Supply, Installation, Testing and commissioning of Gooseneck microphone with Shock Mount
od7457/2021_2022 : Supply, Installation, Testing and commissioning of 7200 lumens WXGA DLP projector
od7458/2021_2022 : Supply, Installation, Testing and commissioning of pole mount kit for the projector
od7459/2021_2022 : Supply, Installation, Testing and commissioning of 55" Full HD LED Display with necessary accessories
od7460/2021_2022 : Supply, Installation, Testing and commissioning of 43" Full HD LED Display with necessary accessories
od7461/2021_2022 : Supply, Installation, Testing and commissioning of integrated Control processor
od7462/2021_2022 : Supply, Installation, Testing and commissioning of Color Touch Screen
od7463/2021_2022 : Supply, Installation, Testing and commissioning of Audio DSP
od7464/2021_2022 : Supply, Installation, Testing and commissioning of 4 X 2 HDMI Matrix Switcher
od7465/2021_2022 : Supply, Installation, Testing and commissioning of Active Wall Plate/ Table Plate
od7466/2021_2022 : Supply, Installation, Testing and commissioning of Video Conferencing System
od7467/2021_2022 : Supply, Installation, Testing and commissioning of end point license
od7468/2021_2022 : Supply, Installation, Testing and commissioning of HDMI Cable - 1 Meter
od7469/2021_2022 : Supply, Installation, Testing and commissioning of HDMI Cable - 15 Meter
od7470/2021_2022 : Supply, Installation, Testing and commissioning of 16/18 AWG Speaker Cable
od7471/2021_2022 : Supply, Installation, Testing and commissioning Connector, audio cable etc
NURSE CALLING SYSTEM
od190224/2020_2021 : Supply, Installation, Testing & Commissioning of Patient Handsets - type with wired console unit.
od190225/2020_2021 : Supply, Installation, Testing & Commissioning of Patient Handsets - type without wired console unit.
od190226/2020_2021 : Supply, Installation, Testing & Commissioning of Toilet Pull Cords with all the necessary accessories for the installation.
od190227/2020_2021 : Supply, Installation, Testing & Commissioning of Light Modules with all the necessary accessories for the installation.
od190228/2020_2021 : Supply, Installation, Testing & Commissioning of Nurse Station Terminals with all the necessary accessories for the installation.
od190229/2020_2021 : Supply, Installation, Testing & Commissioning of system switch communication accessories.
od190230/2020_2021 : Supply, Installation, Testing & Commissioning of management software along with workstation.
TOKEN/QUEUE MANAGEMENT SYSTEM
od7477/2021_2022 : Supply, Installation, Testing & Commissioning of Token Management software with server machine
od7478/2021_2022 : Supply, Installation, Testing & Commissioning of queue Calling Software Client
od7479/2021_2022 : Supply, Installation, Testing & Commissioning of Token Display Unit
od7480/2021_2022 : Supply, Installation, Testing & Commissioning of Touch screen Token/ Vending Machine
HVAC EQUIPMENTS
od44106/2021_2022 : Supply ,Installation and testing and commissioning of Water Cooled Screw Chillers complete with compressor,evaporator and condenser, microprocessor based graphic control panel, I" deflection spring isolators/neoprin rubber pads, necessary star delta starter as required,cooler insulation, victaulic couplings and flow switch, with refrigerant of R134a/R1234ZE, conforming to the specifications and in accordance with the requirements of the schedule of Equipment, suitable to meet the design intent. The chiller shall be supplied fully assembled and tested, BMS compactability with MODBUS factory insulation of cold surfaces with nitrile rubber insulation DP Switches, anty freeze thermostats with grooved end pipe connections, refrigerant and oil with necessary support and accessories. The chillers shall meet the specified IKW / TR , at full load and part loads, relavant documents to be submitted in the tender to substantiate the performancesl. COP/IPLV values strictly followed as per the GRIHA norms.Clearance, Freight up to site Transportation, insurance etc. to be included in the installation.The capacities are as shown.400 TR(3Working + 1Stand By)
od90068/2021_2022 : Supply ,Installation and testing and commissioning of Condenser water Pumpset-Variable speed end suction back pullout type pumps of specified make and capacity complete with base frame, motor coupling, mechanical shaft seal, nosing frames for the pedestals, floating floors and as per specification and equipment schedule with BMS compactability and VFD.all electrical cabling from the VFD panel to the relevant pumps with suitable isoaltors, including VFD's and Control panels to be priced under this scope with necessary support and accessories.CI body with bronze impeller and IE3 efficiency class motor. -(3Working + 1Stand By),Flow : 1600(US GPM),Head : 30 (Mtr)<br>
od90070/2021_2022 : Supply ,Installation and testing and commissioning of Primary CHW Pumpset- Constant speed End suction back pullout type Chilled water pumps of specified make and capacity complete with base frame, motor coupling, mechanical shaft seal, nosing frames for the pedestals,floating floors and as per specification and equipment schedule with BMS compactability and with control panels.. Electrical cabling from the starter panel to the relevant pumps, to be priced under this scope with all necessary support and accessories.CI body with bronze impeller and IE3 efficiency class motor. -(3Working + 1Stand By),Flow : 960(US GPM),Head : 15(Mtr)<br>
od90090/2021_2022 : Supply ,Installation and testing and commissioning of Secondary CHW Pumpset- Variable speed End suction back pullout type Chilled water pumps of specified make and capacity complete with base frame, motor coupling, mechanical shaft seal, nosing frames for the pedestals,floating floors and as per specification and equipment schedule with BMS compactability , VFD and Control Panel. electrical cabling from the starter panel to the relevant pumps, to be priced under this scope with all necessary supports and accessories.CI body with bronze impeller and IE3 efficiency class motor. (3Working + 1Stand By),Flow : 960(US GPM),Head : 35(Mtr)<br>
od61871/2020_2021 : "<br>"" Supply, Installation, Testing and Commissioning of factory built Floor mounted Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain AL sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 8 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings , strip heaters (3x1.5KW), germicidal UV-C lamps etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Floor mounted AHU 2.5 TR/ 950 CFM/ 8 RD/ ESP 217 Pa<br>
od61872/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Floor mounted/ Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain AL sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 8 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings , strip heaters (3x1.5KW), germicidal UV-C lamps etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Floor mounted AHU 5.6 TR/ 2208 CFM/ 8 RD/ ESP -235 Pa
od61873/2020_2021 : "<br>"" Supply, Installation, Testing and Commissioning of factory built Floor mounted Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain AL sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 8 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings , strip heaters (3x1.5KW), germicidal UV-C lamps etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Floor mounted AHU _10.8 TR/ 4931 CFM/ 8 RD/ ESP - 235 Pa
od84374/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Floor mounted Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain AL sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 8 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings , strip heaters (3x1.5KW), germicidal UV-C lamps etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Floor mounted AHU 8.4 TR/ 4387 CFM/ 8 RD/ ESP - 235 Pa.
od61875/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Floor mounted Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain AL sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 8 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings , strip heaters (3x1.5KW), germicidal UV-C lamps etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Floor mounted AHU 8.1 TR/ 4242 CFM/ 8 RD/ ESP -235 Pa
od61876/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Floor mounted Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain AL sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 8 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings , strip heaters (3x1.5KW), germicidal UV-C lamps etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Floor mounted AHU 9.1 TR/ 4480 CFM/ 8 RD/ ESP -235 Pa
od61877/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Floor mounted Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain AL sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 8 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings , strip heaters (3x1.5KW), germicidal UV-C lamps etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal /Floor mounted AHU 7.8 TR/ 4120 CFM/ 8 RD/ ESP -235 Pa
od62753/2020_2021 : "<br>"" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended/ AHU 1 TR/ 400 CFM/ 6 RD/ ESP -127 Pa<br>
od62798/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 1.5 TR/ 600 CFM/ 6 RD/ ESP -127 Pa
od62801/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 2 TR/ 780 CFM/ 6 RD/ ESP -127 Pa
od62929/2020_2021 : <br>Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended/ AHU 2.5 TR/ 845 CFM/ 6 RD/ ESP - 125 Pa
od62955/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 3.0 TR/ 1060 CFM/ 6 RD/ ESP -132 Pa
od63010/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 3.6 TR/ 1299 CFM/ 6 RD/ ESP - 132 Pa
od63020/2020_2021 : " Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 4.0 TR/ 1525 CFM/ 6 RD/ ESP - 135 Pa
od63039/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended/ AHU 4.5 TR/ 2194 CFM/ 6 RD/ ESP -138 Pa
od63239/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 5.0 TR/ 1570 CFM/ 6 RD/ ESP -132 Pa
od63356/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 5.4 TR/ 1829 CFM/ 6 RD/ ESP - 141 Pa
od63633/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 6.0 TR/ 1750 CFM/ 6 RD/ ESP - 142 Pa
od63649/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended/ AHU 6.5 TR/ 1970 CFM/ 6 RD/ ESP - 142 Pa
od63838/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 7.0 TR/ 2200 CFM/ 6 RD/ 144 Pa,6 Row
od63870/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 7.4 TR/ 2384 CFM/ 6 RD/ ESP -138 Pa
od63965/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 8.0 TR/ 2660 CFM/ 6 RD/ ESP -144 Pa
od64007/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 8.5 TR/ 2759 CFM/ 6 RD/ 149 Pa,6 Row
od64255/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 9.0 TR/ 2755 CFM/ 6 RD/ 155 Pa, 6 Row
od64266/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 17.3 TR/ 4600 CFM/ 6 RD/ 162 Pa,6 Row
od64267/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 11.3 TR/ 2745 CFM/ 6 RD/ ESP -141 Pa
od64268/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 10.5TR/ 2628 CFM/ 6 RD/ ESP - 152 Pa,6 Row
od64269/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 10.0 TR/ 3355 CFM/ 6 RD/ ESP - 160 Pa
od64271/2020_2021 : <br>" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 9.5 TR/ 2722 CFM/ 6 RD/ 155 Pa, 6 Row
od64350/2020_2021 : Supply ,Installation and testing and commissioning of Fan coil Units complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, insulated condensate drain pan (extended), coil piping connections (bimetallic union/union connectiors), condensate drain connections, return air plenum with dampers, Flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, FCU, PICV as shown in the drawings and specifications. All units shall be suitable for 240 +/-10% volts, 3 speed and required lengths of wiring 1.0 TR, 400 CFM<br>
od64351/2020_2021 : Supply ,Installation and testing and commissioning of Fan coil Units complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, insulated condensate drain pan (extended), coil piping connections (bimetallic union/union connectiors), condensate drain connections, return air plenum with dampers, Flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, FCU, PICV as shown in the drawings and specifications. All units shall be suitable for 240 +/-10% volts, 3 speed and required lengths of wiring.1.5 TR, 600 CFM<br>
od64980/2020_2021 : Supply ,Installation and testing and commissioning of Fan coil Units complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, insulated condensate drain pan (extended), coil piping connections (bimetallic union/union connectiors), condensate drain connections, return air plenum with dampers, Flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, FCU, PICV as shown in the drawings and specifications. All units shall be suitable for 240 +/-10% volts, 3 speed and required lengths of wiring 2.0 TR, 800<br>
od65128/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen. 2.5 TR, 1000 CFM<br>
od66156/2020_2021 : Supply ,Installation and testing and commissioning of Fan coil Units complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, insulated condensate drain pan (extended), coil piping connections (bimetallic union/union connectiors), condensate drain connections, return air plenum with dampers, Flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, FCU, PICV as shown in the drawings and specifications. All units shall be suitable for 240 +/-10% volts, 3 speed and required lengths of wiring 3.2 TR, 1125 CFM<br>
od69617/2020_2021 : Supply ,Installation and testing and commissioning of Fan coil Units complete with chilled water cooling coil, centrifugal fan, cleanable fabric filters, flushing by pass arrangement, insulated condensate drain pan (extended), coil piping connections (bimetallic union/union connectiors), condensate drain connections, return air plenum with dampers, Flexible duct connectors, including thermostats that are BMS compatible, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, FCU, PICV as shown in the drawings and specifications. All units shall be suitable for 240 +/-10% volts, 3 speed and required lengths of wiring 3.5 TR, 1400 CFM<br>
od69833/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:2314 CFM, ESP 19mm
od69834/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:2704 CFM, ESP 16mm
od69888/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:3316 CFM, ESP 27mm
od69889/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:3692 CFM, ESP 21mm
od69912/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:1214 CFM, ESP 18mm
od69913/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:2178 CFM, ESP 17mm
od69914/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:1528 CFM, ESP 18mm
od69915/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:1008 CFM, ESP 15mm
od70752/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:3040 CFM, ESP 18mm
od70753/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:2919 CFM, ESP 20mm
od70754/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:2179 CFM, ESP 20mm
od70781/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:4663 CFM, ESP 20mm
od70782/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:2959 CFM, ESP 23mm
od70783/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:3089 CFM, ESP 22mm
od70845/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:880 CFM, ESP 15mm
od70846/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:1272 CFM, ESP 17mm
od70847/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:2460 CFM, ESP 17mm
od70848/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:2132 CFM, ESP 15mm
od70849/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:1621 CFM, ESP 11mm
od70850/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:2203 CFM, ESP 22mm
od70921/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:1122 CFM, ESP 17mm
od70922/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:2900 CFM, ESP 26mm
od70923/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:3272 CFM, ESP 25mm
od70924/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:2571 CFM, ESP 20mm
od70925/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:4276 CFM, ESP 22mm
od71005/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:2155 CFM, ESP 15mm
od71006/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:2177 CFM, ESP 19mm
od71007/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:3211 CFM, ESP 15mm
od71008/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:323 CFM, ESP 10mm
od71009/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:3494 CFM, ESP 13mm
od71010/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:1170 CFM, ESP 16mm
od71011/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:2976 CFM, ESP 15mm
od71012/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:4893 CFM, ESP 21mm
od71250/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:696 CFM, ESP 15mm
od243896/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:1434 CFM, ESP 15mm
od243897/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:1599 CFM, ESP 15mm
od243898/2020_2021 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. as specified and as indicated in the equipment schedules and drawings for the following:1574 CFM, ESP 15mm
od72742/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 10000 CFM ESP 14mm
od72943/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 1150 CFM, ESP 11 mm
od73374/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 1240 CFM 19mm
od73376/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 1040 CFM ESP 15mm
od73422/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 1400 CFM ESP 11mm
od73425/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 1300 CFM ESP 11mm
od73431/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 150 CFM ESP 11mm
od73453/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 2132 CFM ESP 20mm
od90191/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 200 CFM ESP 10mm
od73455/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 1885 CFM ESP 15mm
od73464/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 300 CFM ESP 16mm
od73467/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 250 CFM ESP 13mm
od73468/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 2460 CFM ESP 14mm
od73600/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 430 CFM ESP 13mm
od73686/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 500 CFM. ESP 10mm
od73830/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 700 CFM ESP 11mm
od73834/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 570 CFM ESP 11mm
od73966/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 965 CFM ESP 12mm
od73969/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 800 CFM ESP 11mm
od74112/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 880 CFM ESP 16mm
od242718/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 2640 CFM ESP 30mm
od242719/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 4720 CFM ESP 32mm
od242721/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 3960 CFM<br>
od242722/2020_2021 : Inline Fans - for Toilet, Plant room exhaust: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 3305 CFM,<br>
od344977/2020_2021 : Supply, Installation, Testing and Commissioning of CO sensors and necessary cabling required with necessary accessories and supports
od74695/2020_2021 : Carrying out Computation Fluid Dynamics (CFD) simulation for Jet Fans / CO sensors
od74696/2020_2021 : Supply, installing, testing and commissioning of 2 speed Jet fans with factory fitted silencers (minimum 2D Long each ),Bird Screen at both ends fans suitable for High temperature Operation 300°C-2hrs as per EN12101-3-2015 certified with aerodynamic Aerofoil impeller for maximum thrust and low noise emissions, compact design for low ceiling heights, with power and control wiring and starter panal with PLC to control extraxt fan, jet fans andco sensors .Jet fans(Final numbers and location of fans to be ascertained by the specialist contractor by carrying out the CFD analysis)
od74697/2020_2021 : Supply installation testing and commissioning of 100 CFM wall mounted propeller fan with necessary support and accessories<br>
od248868/2020_2021 : Supply ,installation and testing of air Curtain with with all neccessary accessories and supports as specified in the specification (Standart Door Size) 1100 CFM,(DIM-900X230X212)<br>
od34093/2021_2022 : Supply ,installation and testing of,high temperature,low noice Long Casing Tube axial fan with aerofoil blades with AMCA certification for Air & Sound and it can be able to demonstrate in amca certified Lab & Certified for 250 Deg Celsius 2 Hours operation as per EN12101-3-2015 and electrical panel,PLC based digital model controller to monitor inputs from CO sensors,A serial communication port to integrate with BMS. with all necessary accessories and supports.19350 CFM, ESP - 500 Pa
od34094/2021_2022 : Supply ,installation and testing of, high temperature ,low noise Long Casing Tube axial fan with aerofoil blades with AMCA certification for Air & Sound and it can be able to demonstrate in AMCA certified Lab & Certified for 250 Deg Celsius 2 Hours operation as per EN12101-3-2015 with all necessary accessories and supports. Electrical panel connected to Axial fans 15500 CFM, ESP- 500 Pa
od349413/2021_2022 : <br>" Supply, Installation, Testing and Commissioning of factory built Floor mounted/Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended/Floor mounted AHU 3.6 TR/ 1299 CFM/ 6 RD/ ESP - 132 Pa
od349414/2021_2022 : <br>" Supply, Installation, Testing and Commissioning of factory built /Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 4.0 TR/ 1525 CFM/ 6 RD/ ESP - 135 Pa
od349415/2021_2022 : <br>" Supply, Installation, Testing and Commissioning of factory built Floor mounted/Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended/Floor mounted AHU 4.5 TR/ 2194 CFM/ 6 RD/ ESP -138 Pa
od349427/2021_2022 : <br>" Supply, Installation, Testing and Commissioning of factory built Floor mounted/Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended/Floor mounted AHU 5.0 TR/ 1570 CFM/ 6 RD/ ESP -132 Pa
od349447/2021_2022 : <br>" Supply, Installation, Testing and Commissioning of factory built Floor mounted/Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended/Floor mounted AHU 5.4 TR/ 1829 CFM/ 6 RD/ ESP - 141 Pa
od349449/2021_2022 : <br>" Supply, Installation, Testing and Commissioning of factory built Floor mounted/Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended/Floor mounted AHU 6.0 TR/ 1750 CFM/ 6 RD/ ESP - 142 Pa
od349467/2021_2022 : " Supply, Installation, Testing and Commissioning of factory built Floor mounted/Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended/Floor mounted AHU 6.5 TR/ 1970 CFM/ 6 RD/ ESP - 142 Pa<br>
od349507/2021_2022 : <br>" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 7.0 TR/ 2200 CFM/ 6 RD/ ESP - 144 Pa
od349536/2021_2022 : "<br>"" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 8.0 TR/ 2660 CFM/ 6 RD/ ESP -144 Pa<br>
od349564/2021_2022 : "<br>"" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 8.5 TR/ 2759 CFM/ 6 RD/ ESP - 149 Pa<br><br>
od349585/2021_2022 : "<br>"" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 9.0 TR/ 2755 CFM/ 6 RD/ ESP -155 Pa<br><br>
od349599/2021_2022 : "<br>"" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 9.5 TR/ 2722 CFM/ 6 RD/ ESP -155 Pa<br>
od349614/2021_2022 : "<br>"" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 10.5 TR/ 2628 CFM/ 6 RD/ ESP - 152 Pa<br>
od349645/2021_2022 : "<br>"" Supply, Installation, Testing and Commissioning of factory built Ceiling Suspended Chilled water Double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU 17.3 TR/ 4600 CFM/ 6 RD/ ESP - 162 Pa
CHILLED WATER PIPING
od346988/2020_2021 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water chilled water MS C-class pipe, installed with grooved couplings(with necessary clamps, vibration isolators ,elbows, reducer,and fittings.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc with necessary supports and accessories as per specifications and as required complete in all respect.350 mm dia. (75 mm thick insulation)
od346989/2020_2021 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water chilled water MS C-class pipe, installed with grooved couplings(with necessary clamps, vibration isolators ,elbows, reducer,and fittings.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc with necessary supports and accessories as per specifications and as required complete in all respect.300 mm dia. (75 mm thick insulation)
od346990/2020_2021 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water chilled water MS C-class pipe, installed with grooved couplings(with necessary clamps, vibration isolators ,elbows, reducer,and fittings.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc with necessary supports and accessories as per specifications and as required complete in all respect.250 mm dia. (75 mm thick insulation)
od346991/2020_2021 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water chilled water MS C-class pipe, installed with grooved couplings(with necessary clamps, vibration isolators ,elbows, reducer,and fittings.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc with necessary supports and accessories as per specifications and as required complete in all respect.200 mm dia. (75 mm thick insulation)
od346992/2020_2021 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water chilled water MS C-class pipe, installed with grooved couplings(with necessary clamps, vibration isolators ,elbows, reducer,and fittings.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc with necessary supports and accessories as per specifications and as required complete in all respect.150 mm dia. (75 mm thick insulation)
od346993/2020_2021 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water chilled water MS C-class pipe, installed with grooved couplings(with necessary clamps, vibration isolators ,elbows, reducer,and fittings.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc with necessary supports and accessories as per specifications and as required complete in all respect.125 mm dia. (50 mm thick insulation)
od346994/2020_2021 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water chilled water MS C-class pipe, installed with grooved couplings(with necessary clamps, vibration isolators ,elbows, reducer,and fittings.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc with necessary supports and accessories as per specifications and as required complete in all respect.100 mm dia. (50 mm thick insulation)
od346995/2020_2021 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water chilled water MS C-class pipe, installed with grooved couplings(with necessary clamps, vibration isolators ,elbows, reducer,and fittings.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc with necessary supports and accessories as per specifications and as required complete in all respect.80 mm dia. (50 mm thick insulation)
od346996/2020_2021 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water chilled water MS C-class pipe, installed with grooved couplings(with necessary clamps, vibration isolators ,elbows, reducer,and fittings.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc with necessary supports and accessories as per specifications and as required complete in all respect.65 mm dia. (50 mm thick insulation)
od346997/2020_2021 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water chilled water MS C-class pipe, installed with grooved couplings(with necessary clamps, vibration isolators ,elbows, reducer,and fittings.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc with necessary supports and accessories as per specifications and as required complete in all respect.50 mm dia. (50 mm thick insulation)
od346998/2020_2021 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water chilled water MS C-class pipe, installed with grooved couplings(with necessary clamps, vibration isolators ,elbows, reducer,and fittings.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc with necessary supports and accessories as per specifications and as required complete in all respect.40 mm dia. (50 mm thick insulation)
od346999/2020_2021 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water chilled water MS C-class pipe, installed with grooved couplings(with necessary clamps, vibration isolators ,elbows, reducer,and fittings.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc with necessary supports and accessories as per specifications and as required complete in all respect.32 mm dia. (50 mm thick insulation)
od347000/2020_2021 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water chilled water MS C-class pipe, installed with grooved couplings(with necessary clamps, vibration isolators ,elbows, reducer,and fittings.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc with necessary supports and accessories as per specifications and as required complete in all respect.25 mm dia. (50 mm thick insulation)
od347001/2020_2021 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water chilled water MS C-class pipe, installed with grooved couplings(with necessary clamps, vibration isolators ,elbows, reducer,and fittings.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc with necessary supports and accessories. as per specifications and as required complete in all respect.20 mm dia. (50 mm thick insulation)
od80409/2020_2021 : Supplying, fixing, testing and commissioning of BUTTERFLY VALVE (MANUAL) in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified,250 mm dia
od80410/2020_2021 : Supplying, fixing, testing and commissioning of BUTTERFLY VALVE (MANUAL) in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified,350 mm dia
16.7.1.1 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedBUTTERFLY VALVE (MANUAL) 200 mm
od125949/2021_2022 : Supplying, fixing, testing and commissioning of BUTTERFLY VALVE (MANUAL) in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified.100 mm dia.
16.7.1.5 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedBUTTERFLY VALVE (MANUAL) 80 mm
16.7.1.6 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedButterfly valve (Manual) 65 mm
16.7.1.7 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedBUTTERFLY VALVE (MANUAL) 50mm
16.7.1.8 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedButterfly valve (Manual) 40 mm
od80421/2020_2021 : Supplying, fixing, testing and commissioning of BALL VALVE (MANUAL) in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.with C I body , PN 16 pressure rating for chilled water/ hot eater circulation as specified,20 mm dia.
od80422/2020_2021 : Supplying, fixing, testing and commissioning of BALL VALVE (MANUAL) in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.with C I body , PN 16 pressure rating for chilled water/ hot eater circulation as specified,25 mm dia.
od80423/2020_2021 : Supplying, fixing, testing and commissioning of BALL VALVE (MANUAL) in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.with C I body , PN 16 pressure rating for chilled water/ hot eater circulation as specified ,32 mm dia.
16.7.3.1 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.NON- RETURN VALVE with duel plate of C I body SS plated vulcanized NBR Seal flanged end & PN 16 pressure rating for chilled/ hot water circulation including insulation as specified.NON- RETURN VALVE of 200 mm dia
16.7.2.1 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Balancing valve with built in measuring facility with C.I Body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled /hot water circulation as specified.Balancing valve with built in measuring facility 200 mm
16.7.2.4 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Balancing valve with built in measuring facility with C.I Body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled /hot water circulation as specified.Balancing valve with built in measuring facility 100 mm dia
16.7.2.5 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Balancing valve with built in measuring facility with C.I Body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled /hot water circulation as specified.Balancing valve with built in measuring facility 80 mm dia
16.7.2.6 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Balancing valve with built in measuring facility with C.I Body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled /hot water circulation as specified.Balancing valve with built in measuring facility 65 mm dia
16.7.2.7 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Balancing valve with built in measuring facility with C.I Body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled /hot water circulation as specified.Balancing valve with built in measuring facility 50 mm dia
od80427/2020_2021 : Supplying, fixing, testing and commissioning of BALANCING VALVE WITH BUILT IN MEASURING FACILITY in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.25 mm dia
16.11.4.6 : Supply, Installation, Testing and Commissioning of following sizes electronic, selfbalancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valves in a single body. The actuator shall be capable of accepting upto 1 OV DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and not be less than 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 1650mm dia.
16.11.4.7 : Supply, Installation, Testing and Commissioning of following sizes electronic, selfbalancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valves in a single body. The actuator shall be capable of accepting upto 1 OV DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and not be less than 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 1640mm dia.
16.11.4.8 : Supply, Installation, Testing and Commissioning of following sizes electronic, selfbalancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valves in a single body. The actuator shall be capable of accepting upto 1 OV DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and not be less than 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 1632mm dia.
16.11.4.9 : Supply, Installation, Testing and Commissioning of following sizes electronic, selfbalancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valves in a single body. The actuator shall be capable of accepting upto 1 OV DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and not be less than 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 1625mm dia.
16.11.4.10 : Supply, Installation, Testing and Commissioning of following sizes electronic, selfbalancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valves in a single body. The actuator shall be capable of accepting upto 1 OV DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and not be less than 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 1620mm dia.
16.7.4.1 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of 200 mm dia
16.7.4.7 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of Ductile of 50 mm dia
16.7.4.8 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of 40 mm dia
od80464/2020_2021 : Supplying, fixing, testing and commissioning of following Y - STRAINERin the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.with Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.20 mm Dia
od80465/2020_2021 : Supplying, fixing, testing and commissioning of following Y - STRAINERin the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.with Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.25 mm Dia
od80466/2020_2021 : Supplying, fixing, testing and commissioning of following Y - STRAINERin the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.with Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.32 mm Dia
od80512/2020_2021 : Supplying, fixing, testing and commissioning of following sizes Motorized Butterfly Valve with insulation, CI Body, SS Disc, O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20 mA electric signal and providing similar transduced feedback output to control system as required with necessary support and accessories 200 mm dia.
od80529/2020_2021 : Supplying, fixing, testing and commissioning of RUBBER BELLOW Insulation as shown and as specified in the specifications and drawings with all necessary Support,200 mm dia.
16.8 : Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
16.9 : Providing & fixing in position the mercury in glass industrial type thermometers.
od80766/2020_2021 : Supplying, fixing, testing and commissioning of Cast Iron Automatic Air release vents with valve on pipes of suitable diaRmtrs as shown and as specified in the specifications and drawings. 25mm dia
od347002/2020_2021 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of condenser water water MS C-class pipe, installed with grooved couplings(with necessary clamps, vibration isolators, elbows, reducer,and fittings etc.)with necessary support and accessories, 150 mm dia
od347003/2020_2021 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of condenser water water MS C-class pipe, installed with grooved couplings(with necessary clamps, vibration isolators, elbows, reducer,and fittings etc.)with necessary support and accessories,250 mm dia
od347004/2020_2021 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of condenser water water MS C-class pipe, installed with grooved couplings(with necessary clamps, vibration isolators, elbows, reducer,and fittings etc.)with necessary support and accessories<br>400 mm dia
od80973/2020_2021 : Supplying, fixing, testing and commissioning of following valves,gauges and strainers for condenser water circulation as per<br>specifications. BUTTERFLY VALVE (MANUAL) with CI body SS disc nitrilesheet & O - ring & PN 16 pressure rating as specified.<br>250 mm dia.
16.11.1.4 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) 100 mm dia
16.11.1.7 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) 50 mm dia
od80984/2020_2021 : Supplying, fixing, testing and commissioning of RUBBER BELLOW as shown and as specified in the specifications and drawings with all necessary Support.<br>250 mm dia.
od80985/2020_2021 : Supplying, fixing, testing and commissioning of following Y - STRAINER for condenser water circulation as per specifications, with Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 250 mm dia.
od81282/2020_2021 : Supplying, fixing, testing and commissioning of following valves,gauges and strainers for condenser water circulation as per<br>specificationsNON - RETURN VALVE with dual plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as<br>specified.250 mm dia.
16.11.3.3 : Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valves with Cl Body, SS Disc,O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required.250mm dia.
od85418/2020_2021 : Supplying, fixing, testing and commissioning of UPVC Class E condensate drain pipe with U trap, insulation & fittings up to drain line with necessary support and accessories, 20mm Dia
od85419/2020_2021 : Supplying, fixing, testing and commissioning of UPVC Class E condensate drain pipe with U trap, insulation & fittings up to drain line with necessary support and accessories. 25mm Dia
od85420/2020_2021 : Supplying, fixing, testing and commissioning of UPVC Class E condensate drain pipe with U trap, insulation & fittings up to drain line with necessary support and accessories, 32mm Dia.
od85421/2020_2021 : Supplying, fixing, testing and commissioning of UPVC Class E condensate drain pipe with U trap, insulation & fittings up to drain line with necessary support and accessories, 50mm Dia
od85590/2020_2021 : Supplying, fixing, testing and commissioning of flow switch on pipes of suitable diaRmtras shown and as specified in the specifications and drawings
od85591/2020_2021 : Supply installation testing and commissioning of Automatic type Chemical dosing system, for chilled water piping and cooling tower piping system as per specification and drawing.
od244797/2020_2021 : Supplying, fixing, testing and commissioning of following sizes BTU meters with BMS Compatibility, cabling , meter reading, sensors and necessary supports and accessories, 25 mm dia
od244798/2020_2021 : Supplying, fixing, testing and commissioning of following sizes BTU meters with BMS Compatibility, cabling , meter reading, sensors and necessary supports and accessories, 50 mm dia.
od244799/2020_2021 : Supplying, fixing, testing and commissioning of following sizes BTU meters with BMS Compatibility, cabling , meter reading, sensors and necessary supports and accessories, 65 mm dia.
od244800/2020_2021 : Supplying, fixing, testing and commissioning of following sizes BTU meters with BMS Compatibility, cabling , meter reading, sensors and necessary supports and accessories,80 mm dia.
od244801/2020_2021 : Supplying, fixing, testing and commissioning of following sizes BTU meters with BMS Compatibility, cabling , meter reading, sensors and necessary supports and accessories,100 mm dia.
od248872/2020_2021 : Supply and fixing of UPVC pipes and fittings / specials like tees, elbows, bends, unions, offsets, Hex nipples collars, cutting, threading the pipes with threading machine, jointing using holdtile and cotton thread or shallock and pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 2 hours etc., including chasing in solid block masonry walls with groove cutting machine to required width and depth, making bores in walls, foundations and RCC slabs, making good the walls and bores in CC or CM 1:3 as applicable clearing the debris, grouting of concealed pipes, MS hooks for fixing pipes and making good the walls and floors.100 mm Dia
od248881/2020_2021 : Supply and fixing of UPVC pipes and fittings / specials like tees, elbows, bends, unions, offsets, Hex nipples collars, cutting, threading the pipes with threading machine, jointing using holdtile and cotton thread or shallock and pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 2 hours etc., including chasing in solid block masonry walls with groove cutting machine to required width and depth, making bores in walls, foundations and RCC slabs, making good the walls and bores in CC or CM 1:3 as applicable clearing the debris, grouting of concealed pipes, MS hooks for fixing pipes and making good the walls and floors, 50mm Dia
DUCTING
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006
16.12.1.2 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006
od81519/2020_2021 : Supply & Installation testing and commissioning of Aluminum duct work in Operation theatres of following Gauges asappropiate with all accessories, supports, jointing materials, flanges complete all inline with theDW 144 or SMACNA and in line with the specifications, drawings etc, Supply and Return ductwork complete (20 G)
od81520/2020_2021 : Supply & Installation testing and commissioning of Aluminum duct work in Operation theatres of following Gauges asappropiate with all accessories, supports, jointing materials, flanges complete all inline with theDW 144 or SMACNA and in line with the specifications, drawings etc, Supply and Return ductwork complete (22 G)
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
od125891/2021_2022 : Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
16.17 : Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.
16.18 : Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.
16.20.1 : Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Fire damper
16.20.2 : Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Actuator
od83271/2020_2021 : Supply & Installation testing and commissioning of Nitrile Foam Rubber (NBR) Open Cell Acoustic Insulation Material with Class 1. Density 180 Kg/M³ - 220 Kg/M³, Thermal Conductivity ≤ 0.040 w/m.k @ O°C, (ASTM C518 & ASTM C177) K Value 0.040, Service Temperature -50ºC - 85ºC, No Fungul growth (ASTM G21), Dust & Fibre free, CFC Free with all neccessary supprt and accessories, Acoustic liner 10 mm Thickness
od83272/2020_2021 : Supply & Installation testing and commissioning of Nitrile Foam Rubber (NBR) Closed Cell Insulation Material on existing duct after applying suitable adhesive for Nitrile rubber,The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape inline with the specifications, drawings with CLASS 1 & O. The Insulation Material Shall be Fire Rated As Per BS 476 Part 6 & 7, Thermal Conductivity 0.032 w/m.k @ O°C (ASTM C518), K Value 0.032 , Density 40 kg/m³ - 70 kg/m³, Service Temperature of -50 °C to 105 °C (85ºC for flat surface & 105ºC for pipes), Water Absorption by Volume ≤ 0.2% (ASTM C209), Water Vapour Permeability ≤ 2.9 X 10 g/pa.m.s, μ ≥ 12,000 (ASTM E96), Ozone Resistance Good, No Corrosion Resistance and Environment: Dust and fibre free CFC Free, Zero ODP, Zero GWP. Reaction to Fire (UL 94 = V-0, 5VA / HF-1 Self - Extinguish, Does not Drip), Anti-Microbial (ASTM E2180) with all neccessary supprt and accessories Thickness-19 mm
od83273/2020_2021 : Supply & Installation testing and commissioning of Nitrile Foam Rubber (NBR) Closed Cell Insulation Material on existing duct after applying suitable adhesive for Nitrile rubber,The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape inline with the specifications, drawings with CLASS 1 & O. The Insulation Material Shall be Fire Rated As Per BS 476 Part 6 & 7, Thermal Conductivity 0.032 w/m.k @ O°C (ASTM C518), K Value 0.032 , Density 40 kg/m³ - 70 kg/m³, Service Temperature of -50 °C to 105 °C (85ºC for flat surface & 105ºC for pipes), Water Absorption by Volume ≤ 0.2% (ASTM C209), Water Vapour Permeability ≤ 2.9 X 10 g/pa.m.s, μ ≥ 12,000 (ASTM E96), Ozone Resistance Good, No Corrosion Resistance and Environment: Dust and fibre free CFC Free, Zero ODP, Zero GWP. Reaction to Fire (UL 94 = V-0, 5VA / HF-1 Self - Extinguish, Does not Drip), Anti-Microbial (ASTM E2180) with all neccessary supprt and accessories Thickness-13 mm
od83287/2020_2021 : Supply, installation, testing and commissioning of Unidirectional Laminar flow plenum for the OT's with HEPA filters .• Plenum Construction : 1 mm Aluminium construction having Aluminium Square tube skeleton structure• Perforated diffuser: 1 mm Stainless Steel (SS-304) Inline Round Perfoaration : 5mm ø,12 mm Pitch• Note: Plenum will be shipped in one single plenum at the site.• Filter fitment : Filter face seating on a self-leveling Poly Urethene compound formed on the Plenum structure. • Thermal insulation : 19 mm thick Class "O" Nitrile insulation with aluminium foil lamination on exterior side.• Duct connecting collar : No. of Duct connecting Collars -Based on user requirements Maximum Height : 225 mm • Volume control dampers : Aluminium Aerofoil Volume Control Damper Operable from the OT side without distrubing filter installation.•UP stream ports : Provision of Up stream ports for Testing & Measurement.• Provision for OT light pendent : Will be Provided. Chute opening Size-520 x 520 mm• Suspension brackets : SS "L" angle brackets for ceiling suspension of the Plenum.•Terminal Air Filter : HEPA filter as per description below• Mini Pleat HEPA Filters, Flange typeCasing : Anodised Aluminium extruded profile - Flange typeMedia : Micro Glass Fibre of "Lydall, France" makePack Depth: 50 mmSealant : PU SealantGasket : 3mm thick XLPEFace Guard : Powder coated, Aluminium flattened expanded metal on both sides of the filtration media pack.Particle size efficiency : ≥ 99.99% @ 0.3 microns .Maximum operating temperature : 50º CEquivalent to : H14 of EN1822-1 TYPE 'D' of TEST - RP - CC - 001.5• Plenum Size: 2350 (L) x 1740 (W) x 455 (H) mm (Excluding Thermal Insulation) • Perforated Diffuser size : 2440 (L) x 1830 (W) mm• Filter Nominal Sizes : 1) 4' x 2' - 4 Nos. 2) 3' x 2' - 2 Nos.HEPA Filter testing standards : IEST : RP : CC : 034<br>Plenum Size : 600mm x 600mm x 150mm
od134286/2020_2021 : Supply & Installation testing and commissioning of Nitrile Foam Rubber (NBR) Closed Cell Insulation Material for under deck with CLASS 1 & O. The Insulation Material Shall be Fire Rated As Per BS 476 Part 6 & 7, Thermal Conductivity 0.032 w/m.k @ O°C (ASTM C518), K Value 0.032 , Density 40 kg/m³ - 70 kg/m³, Service Temperature of -50 °C to 105 °C (85ºC for flat surface & 105ºC for pipes), Water Absorption by Volume ≤ 0.2% (ASTM C209), Water Vapour Permeability ≤ 2.9 X 10 g/pa.m.s, μ ≥ 12,000 (ASTM E96), Ozone Resistance Good, No Corrosion Resistance and Environment: Dust and fibre free CFC Free, Zero ODP, Zero GWP. Reaction to Fire (UL 94 = V-0, 5VA / HF-1 Self - Extinguish, Does not Drip), Anti-Microbial (ASTM E2180)Thickness-25 mm
od83288/2020_2021 : Supply, installation, testing and commissioning of Unidirectional Laminar flow plenum for the BMTs and Isolation Rooms with HEPA filters. • MOC of TFMB : 1 mm thick - SS 304.• MOC of Perforated diffuser : 1 mm thick -SS 304. Inline Round Perforation : 8mm ø,12mm Pitch • Duct connecting collar: Side Duct Connecting collar with VCD.• Volume control Damper :Applicable, Aluminium Aerofoil Volume Control Damper operable from the Cleanroom side without distrubing Filter installation. • Filter Fixing : Filter flange seating on a self-leveling Poly Urethene compound formed on the TFMB structure. • DOP/PAO and Differential Pressure Ports are provided. • Thermal Insulation : 19mm thick Nitrle with aluminium foil lamination.• Suspension brackets : Stainless Steel "L" angle brackets for ceiling suspension of the TFMB.Mini Pleat HEPA Filters. Casing : Flange type, Anodised Aluminium Extruded Profile -1mm thick for Box and 2 mm thick for flange. Media : Micro Glass Fibre of "Lydall, France" make Media Support : EVA Hotmelt Sealant : PU Sealant Gasket : 3mm thick XLPE. Face Guard : Powder Coated, Aluminium flattened expanded metal on both sides of the filtration media. Particle size efficiency : ≥ 99.99% @ 0.3 microns . Maximum operating temperature : 50º C• Perforated Diffuser size : 610 x 610 mm.• TFMB Box size : 580 x 580 x 390 mm (Excluding thermal Insulation)• Side Collar Opening Size :235 x 580 mm (Suject to clients Confirmation)• Size of VCD : 225 (H) x 550(W) x 110(D). Filter Flange Size : 520 (H) x 520 (W) Filter Box size: 460 (H) x 460 (W) x 70 (D) mm • Air Handling Capacity : 350 CFM @ ≤ 23 mm WC IPD<br>Filter Box size: 460 (H) x 460 (W) x 70 (D) mm
od85589/2020_2021 : Supply installation testing and commissioning of Strip Heater 1.5KW x 3Nos with humidistat, senseor,control panel , cabling , all necessary support and accessories
PLANT MANAGER
od184261/2020_2021 : Supply, Installation, testing and commissioning of GI perforated pre - galvanized cable tray without cover - 200 X 50 X 1.2 mm thickness with all necessary support and accessories.
od184262/2020_2021 : Supply, Installation, testing and commissioning of 2C x 1.5 sqmm – YRY armoured (control cabling shielded between CPM and sensors and CPM controllers etc.) with all necessary support and accessories.
od184263/2020_2021 : Supply, Installation, testing and commissioning of 6C x 1.0 sqmm – YRY armoured (control cabling between CPM and HVAC Panel and CPM controllers etc.) with all necessary support and accessories.
od184264/2020_2021 : Supply, Installation, testing and commissioning of 2C x 1.0 sqmm – YRY armoured (control cabling between CPM and chillers, and cooling tower valves and CPM controllers etc.) with all necessary support and accessories.
od184265/2020_2021 : Supply, Installation, testing and commissioning of Differential pressure sensor with all necessary support and accessories
od184266/2020_2021 : Supply, Installation, testing and commissioning of Water level switch with all necessary support and accessories
od184267/2020_2021 : Supply, Installation, testing and commissioning of water type temperature sensors (Immersion) provide tamper proof elements having stainless steel sheath, complete with all accessories for measuring chilled water temperature in header complete as per specification etc., IP 65 rated immersion type sensor.
od184268/2020_2021 : Supply, Installation, testing and commissioning outdoor mountable temperature and RH sensors with all mounting accessories to measure the ambient conditions with all necessary support and accessories.. The sensor should be IP65 rated.
od184269/2020_2021 : Supply installation testing and commissioning of chiller plant manager as per IO summary with all necessary support and accessories.
DATA CENTER
od248849/2020_2021 : Supply ,Installation and testing and commissioning of air cooled chiller35 TR complete with compressor,evaporator , microprocessor based graphic control panel, I" deflection spring isolators/neoprin rubber pads,VFD starter ,cooler insulation, victaulic couplings and flow swith, with refrigerant of R134a/R407c, conforming to the specifications and in accordance with the requirements of the schedule of Equipment, suitable to meet the design intent. The chiller shall be supplied fully assembled and tested, BMS compactability with MODBUS factory insulation of cold sufaces with nitrile rubber insulation DP Switches, anty freeze thermostats with grooved end pipe connectios, refrigerant and oil with necessary support and accessories. The chillers shall meet the specified IKW / TR , at full load and part loads, relavant documents to be submitted in the tender to substantiate the preformances. The Hvac contractor to include for relevant isolator and cabling between isolator and the chiller panel. The capacities are as shown. with inbuilt 1 nos pump and tank ,all necessary support and accessories.
od248850/2020_2021 : Supply ,Installation and testing and commissioning of Stainless Steel Expansion tank with all necessary support and accessories.(100 Litrs)<br>
od248851/2020_2021 : Supply ,Installation and testing and commissioning of Secondary Chilled water pump Variable speed End suction back pullout type Chilled water pumps of specified make and capacity complete with base frame, motor coupling, mechanical shaft seal, nosing frames for the pedestals,floating floors and as per specification and equipment schedule with BMS compactability.. electrical cabling from the starter panel to the relevant pumps, to be priced under this scope with all necessary supports and accessories.CI body with bronze impeller and IE3 efficiency class motor. (1Working + 1Stand By)168 US GPM),Head : 20(Mtr)<br>
od248852/2020_2021 : Supply ,Installation and testing and commissioning of primary Chilled water pump Constant speed End suction back pullout type Chilled water pumps of specified make and capacity complete with base frame, motor coupling, mechanical shaft seal, nosing frames for the pedestals,floating floors and as per specification and equipment schedule with BMS compactability.. electrical cabling from the starter panel to the relevant pumps, to be priced under this scope with all necessary support and accessories.CI body with bronze impeller and IE3 efficiency class motor. -(1Working + 1Stand By)(168 US GPM),Head : (15Mtr)<br>
od346996/2020_2021 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water chilled water MS C-class pipe, installed with grooved couplings(with necessary clamps, vibration isolators ,elbows, reducer,and fittings.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc with necessary supports and accessories as per specifications and as required complete in all respect.65 mm dia. (50 mm thick insulation)
od346998/2020_2021 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water chilled water MS C-class pipe, installed with grooved couplings(with necessary clamps, vibration isolators ,elbows, reducer,and fittings.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc with necessary supports and accessories as per specifications and as required complete in all respect.40 mm dia. (50 mm thick insulation)
16.7.2.6 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Balancing valve with built in measuring facility with C.I Body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled /hot water circulation as specified.Balancing valve with built in measuring facility 65 mm dia
16.7.1.6 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedButterfly valve (Manual) 65 mm
16.7.1.8 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedButterfly valve (Manual) 40 mm
16.7.3.6 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.NON- RETURN VALVE with duel plate of C I body SS plated vulcanized NBR Seal flanged end & PN 16 pressure rating for chilled/ hot water circulation including insulation as specified.NON- RETURN VALVE of 65 mm dia
16.7.4.6 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of 65 mm dia
16.7.4.8 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of 40 mm dia
16.11.3.9 : Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valves with Cl Body, SS Disc,O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required.65mm dia.
16.8 : Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
16.9 : Providing & fixing in position the mercury in glass industrial type thermometers.
od248837/2020_2021 : Supplying, fixing, testing and commissioning of flow switch on pipes of suitable diaRmtras shown and as specified in the specifications and drawings
od248838/2020_2021 : Supplying, fixing, testing and commissioning of BALL VALVE (MANUAL) in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.with C I body , PN 16 pressure rating for chilled water/ hot eater circulation as specified
od248839/2020_2021 : Supplying, fixing, testing and commissioning Automatic Air release vents with valve on pipes of suitable dia Rmtrs as shown and as specified in the specifications and drawings 25mm<br>
Elevator
od82234/2020_2021 : Supply, installation, testing and commissioning of 11 persons passenger/bed lift, side opening, machine room less on top ,serving 5 stops / 5 openings, 2 mps. Size of lift well is 2000mmx2000mm. Travel distance 24600mm
od82235/2020_2021 : Supply, installation, testing and commissioning of 11 persons passenger/bed lift, side opening with machine room on top ,serving 14 stops / 14 openings, 1 mps. Size of lift well is 1800mmx2200mm. Travel distance 50950mm
od82236/2020_2021 : Supply, installation, testing and commissioning of 15 persons service lift for staff & patient travel, centre opening, with machine room less ,serving 13 stops / 13 openings, 2 mps. Size of lift well is 2000mmx2700mm. Travel distance 46500mm
od82237/2020_2021 : Supply, installation, testing and commissioning of 20 persons passenger/bed lift, centre opening, with machine room less ,serving 15 stops / 15 openings, 2 mps. Size of lift well is 2450mmx2950mm. Travel distance 58000mm
od82238/2020_2021 : Supply, installation, testing and commissioning of 20 persons passenger/bed lift, side opening, machine room less ,serving 15 stops / 15 openings, 2 mps. Size of lift well is 2150mmx2950mm. Travel distance 58000mm
od82239/2020_2021 : Supply, installation, testing and commissioning of 20 persons passenger/bed lift, centre opening, machine room less ,serving 12 stops / 12 openings, 2 mps. Size of lift well is 2450mmx2950mm. Travel distance 45300mm
od82240/2020_2021 : Supply, installation, testing and commissioning of 20 persons passenger/bed lift, side opening, with machine room less ,serving 12 stops / 12 openings, 2 mps. Size of lift well is 2150mmx2950mm. Travel distance 45300mm
PNEUMATIC TUBE SYSTEM
od193189/2020_2021 : Supply, Installation,Testing and commissioning of Control centre Software Module upto 40 stations with software licence for all stations including Remote access configuration. The proposed system shall be capable of integarting with the existing PTS system in the campus and to be communicated without any fail.<br>
od193253/2020_2021 : Supply, Installation, Testing and commissioning of all the required hardware accessories for Control Centre including Active connect box, USB converter, Power packs, Licence dongle etc
od193201/2020_2021 : Supply, Installation, Testing and commissioning of the following stations:<br>a)Automatic Front Loading type with Graphic MINOTOR
od193202/2020_2021 : Supply, Installation, Testing and commissioning of the following stations:<br>b)Compact Automatic Bottom Loading type with Graphic MINOTOR<br><br>
od193203/2020_2021 : Supply, Installation, Testing and commissioning of the following stations:<br>c)Horizontal Lab Receiving Station <br><br>
od193204/2020_2021 : Supply, Installation, Testing and commissioning of the following accessories for Stations:<br>a)Carrier Basket<br><br>
od193205/2020_2021 : Supply, Installation, Testing and commissioning of the following accessories for Stations:<br>b)Carrier Rack<br><br>
od193240/2020_2021 : Supply, Installation, Testing and commissioning of the following accessories for Stations:<br>c) Basket Upholstery<br><br><br><br>
od193206/2020_2021 : Supply, Installation, Testing and commissioning of the following accessories for Stations:<br>d)Station Directory<br><br>
od193207/2020_2021 : Supply, Installation, Testing and commissioning of the following accessories for Stations:<br>e)RFID Carrier Reading Device Standard (built-in)<br><br><br>
od193208/2020_2021 : Supply, Installation, Testing and commissioning of Diverter 3-Way.<br><br><br>
od193209/2020_2021 : Supply, Installation, Testing and commissioning of PVC Grey Straight.<br><br>
od193210/2020_2021 : Supply, Installation, Testing and commissioning of PVC Grey 800mmR Bend.<br><br>
od193211/2020_2021 : Supply, Installation, Testing and commissioning of PVC Milky Transparent Straight.<br><br>
od193212/2020_2021 : Supply, Installation, Testing and commissioning of PVC Milky Transparent 800mmR Bend.<br><br><br>
od193213/2020_2021 : Supply, Installation, Testing and commissioning of PVC Sleeves.<br><br>
od193214/2020_2021 : Supply, Installation, Testing and commissioning of Tube Clips.<br>
od193215/2020_2021 : Supply, Installation, Testing and commissioning of Tube Clamps.<br><br><br>
od193216/2020_2021 : Supply, Installation, Testing and commissioning of Tie-Strips.<br>
od193217/2020_2021 : Supply, Installation, Testing and commissioning of Control Cable for Data-Com-Power .<br><br><br>
od193263/2020_2021 : Supply, Installation, Testing and commissioning of Special PVC Glue.<br><br><br>
od193219/2020_2021 : Supply, Installation, Testing and commissioning of Special PVC Cleaner.
od193220/2020_2021 : Supply, Installation, Testing and commissioning of Installation Accessories Lot (Thread Rods, Bolts etc…)
od193221/2020_2021 : Supply, Installation, Testing and commissioning of Optical Tube Switch (built-in).
od193222/2020_2021 : Supply, Installation, Testing and commissioning of Power supply unit.<br>
od193223/2020_2021 : Supply, Installation, Testing and commissioning of Blower Unit Complete with all required Accessories 5.5Kw.
od193224/2020_2021 : Supply, Installation, Testing and commissioning of Zone Transfer Systems with all accessories.
od193225/2020_2021 : Supply, Installation, Testing and commissioning of workstation with all required accessories with the specification recommended for the system
od193226/2020_2021 : Supply, Installation, Testing and commissioning of Standard Carriers.<br>A) 330x120<br><br><br>
od193227/2020_2021 : Supply, Installation, Testing and commissioning of Standard Carriers.<br>B) Foam inset 330 x 120<br><br>
od193228/2020_2021 : Supply, Installation, Testing and commissioning of Standard Carriers.<br>C) RFID Transponders 2 per carrier<br><br>
od187273/2020_2021 : Supply, installation testing and commisioning of Central Computer System: Intel Core i7 processor , 32GB DDR4-RAM, 1TB SATA Hard Disk, DVD Writer, Lan Card 10/100/1000 base-T, 32" LED Monitor , Optical Mouse, 104 Keys Keyboard, Windows 10 operating system, Inbuilt graphics
od187286/2020_2021 : Supply, installation testing and commisioning of A4 size Inkjet Printer suitable for the application, with driver software.
od187288/2020_2021 : Supply, installation testing and commisioning of SOFTWARE: Web Based Graphical interface software based on MS Windows 10 / Latest. The system should be accessible from anywhere on LAN or WAN or Ethernet without additional licenses. The Communication protocol shall be Industry Standard BACNET Open Protocol. System should be scalable. The software shall be open system architecture type which facilitates interoperability with other system over BACNET IP with complete control and monitoring functions. Software shall work in the WEB environment supporting HTML5, unlimited concurrent client users license on LAN / WEB. Software shall be certified and complying to BACnet Advanced Operator Workstation
DDC CONTROLLERS WITH IP
INTEGRATION
od187396/2020_2021 : Required Gateway / Open Protocol Software for integrating the following third party system communicating on one of the Standard Open Protocols such as BACNet , MODBUS, M-Bus, etc. - Vendor to considered required No. of Integrators for qty's mentioned in IO summary.<br>Chiller Plant Manager<br>
od187397/2020_2021 : Required Gateway / Open Protocol Software for integrating the following third party system communicating on one of the Standard Open Protocols such as BACNet , MODBUS, M-Bus, etc. - Vendor to considered required No. of Integrators for qty's mentioned in IO summary.<br>UPS<br>
od187398/2020_2021 : Required Gateway / Open Protocol Software for integrating the following third party system communicating on one of the Standard Open Protocols such as BACNet , MODBUS, M-Bus, etc. - Vendor to considered required No. of Integrators for qty's mentioned in IO summary.<br>DG <br>
od187399/2020_2021 : Required Gateway / Open Protocol Software for integrating the following third party system communicating on one of the Standard Open Protocols such as BACNet , MODBUS, M-Bus, etc. - Vendor to considered required No. of Integrators for qty's mentioned in IO summary.<br>SCADA<br>
od187400/2020_2021 : Required Gateway / Open Protocol Software for integrating the following third party system communicating on one of the Standard Open Protocols such as BACNet , MODBUS, M-Bus, etc. - Vendor to considered required No. of Integrators for qty's mentioned in IO summary.<br>Lifts<br>
od187401/2020_2021 : Required Gateway / Open Protocol Software for integrating the following third party system communicating on one of the Standard Open Protocols such as BACNet , MODBUS, M-Bus, etc. - Vendor to considered required No. of Integrators for qty's mentioned in IO summary.<br>Medical Gas System<br>
od187402/2020_2021 : Required Gateway / Open Protocol Software for integrating the following third party system communicating on one of the Standard Open Protocols such as BACNet , MODBUS, M-Bus, etc. - Vendor to considered required No. of Integrators for qty's mentioned in IO summary.<br>Fire Alarm System<br>
od187403/2020_2021 : Required Gateway / Open Protocol Software for integrating the following third party system communicating on one of the Standard Open Protocols such as BACNet , MODBUS, M-Bus, etc. - Vendor to considered required No. of Integrators for qty's mentioned in IO summary.<br>FCU Thermostats<br>
od314715/2020_2021 : Required Gateway / Open Protocol Software for integrating the following third party system communicating on one of the Standard Open Protocols such as BACNet , MODBUS, M-Bus, etc - Vendor to consider required No. of Integrators and controllers for qty's mentioned in IO summary<br>BTU Meters
od314716/2020_2021 : Required Gateway / Open Protocol Software for integrating the following third party system communicating on one of the Standard Open Protocols such as BACNet , MODBUS, M-Bus, etc - Vendor to consider required No. of Integrators and controllers for qty's mentioned in IO summary.<br>Water meters
SENSORS AND FIELD DEVICES
od187429/2020_2021 : Supply, installation testing and commisioning of Duct type Temperature Sensor .<br>
od187430/2020_2021 : Supply, installation testing and commisioning of Air Flow Switch .<br>
od187431/2020_2021 : Supply, installation testing and commisioning of Differential pressure switch.<br>
od187432/2020_2021 : Supply, installation testing and commisioning of Immersion Temperature Sensors.<br>
od187433/2020_2021 : Supply, installation testing and commisioning of Level sensor for Water Tank.<br>
od187434/2020_2021 : Supply, installation testing and commisioning of Differential Pressure Transmitter for Air<br>
od187435/2020_2021 : Supply, installation testing and commisioning of Differential water Pressure Transmitter<br>
od187436/2020_2021 : Supply, installation testing and commisioning of Flameproof Tank Level Sensor - Diesel<br>
od187437/2020_2021 : Supply, installation testing and commisioning of Ambient Temperature Sensor( Outdoor )<br>
od187438/2020_2021 : Supply, installation testing and commisioning of Outside RH Sensor<br>
od187439/2020_2021 : Supply, installation testing and commisioning of PH Sensor<br>
od187440/2020_2021 : Supply, installation testing and commisioning of Ambient Temp. & RH sensor with radiation shield<br>
WIRING
od187441/2020_2021 : Supply, laying, testing and commisioning of 2Cx 1.0 Sqmm PVC insulated, Tinned Copper Conductor Cable- Unscreened<br>
od187442/2020_2021 : Supply, laying, testing and commisioning of 4Cx 1.0 Sqmm PVC insulated, Tinned Copper Conductor Cable- Unscreened<br>
od187443/2020_2021 : Supply, laying, testing and commisioning of 2Cx 1.0 Sqmm PVC insulated, Tinned Copper Conductor Cable- Screened<br>
od187444/2020_2021 : Supply, laying, testing and commisioning of 4Cx 1.0 Sqmm PVC insulated, Tinned Copper Conductor Cable- Screened<br>
od187445/2020_2021 : Supply, laying, testing and commisioning of 2Cx 1.5 Sqmm PVC insulated, Tinned Copper Conductor Cable- Shielded<br>
CONDUITING
od187447/2020_2021 : Supply and laying of 25MM PVC Conduit with all accessories.<br>
od187448/2020_2021 : Supply and laying of Perforated Cable Tray with cover and Accessories - 300mmx50mmx2mm<br>
od187449/2020_2021 : Supply and laying of Perforated Cable Tray with cover and Accessories - 200mmX50mmX2mm<br>
od187450/2020_2021 : Supply and laying of Perforated Cable Tray with cover and Accessories - 100mmX50mmX2mm<br>
INCINERATOR
od195722/2020_2021 : Supply, constructing and commissioning of 100kg/hr double chamber Biomedical waste incinerator diesel-fired with quench column, venturi scrubber, moisture seperator, FD fan, ID fan and recirculation pumps (As per CPCB norms). Chimney of 6m height from terrace with inner FRP lining. <br>Incinerator cost includes 5- year warranty and 5-year CAMC after the warranty period.<br>
Machineries for 150KLD ETP
od81918/2021_2022 : Supply Installation Testing Commissioning of ETP.<br><br><br>1.1 no of Coarse Screen MOC : SS<br>304<br><br><br>2.2 nos (1w+1 stby) of Effluent Transfer pumps of Capacity : 7.5 m3/hr@10m self<br>priming<br><br> 3.1set Stirrer for Flocculation<br>tank MOC : SS 304 1 set"<br>"<br><br>4.2 nos of<br>Dosing System Accessories : Dosing pump with<br>tank.<br><br>5.1 lot of Piping work with<br>valves<br>in the ETP area.<br><br>6.1 lot of Electrification works<br><br>7.Plumbing pipes and<br>fittings(water supply vent)
Signages
od195305/2020_2021 : Providing and fixing / holding sinages, sign board made of compact aluminium panel sheet or HPL sheet of approved shade , providing 3mm vinyl pased letters with multi language (engilsh & malayalam) and logos of approved sizes, providing side hangers fixing in position,providing centre handers using Ms rods amn chains etc. displaying scope of services, room numbers, doctors rooms, HOD rooms, floor wise facilities ,radiation sinages, mandatory notification as directed by the engineer in charge with one side lettering for fixed in wall and both sides as in projected type etc. complete to detailed pre approved plan.<br>Scope fo services in all deptmt- 120x150cm .<br>
od195306/2020_2021 : Providing and fixing / holding sinages, sign board made of compact aluminium panel sheet or HPL sheet of approved shade , providing 3mm vinyl pased letters with multi language (engilsh & malayalam) and logos of approved sizes, providing side hangers fixing in position,providing centre handers using Ms rods amn chains etc. displaying scope of services, room numbers, doctors rooms, HOD rooms, floor wise facilities ,radiation sinages, mandatory notification as directed by the engineer in charge with one side lettering for fixed in wall and both sides as in projected type etc. complete to detailed pre approved plan.<br>Stair area 120x100cm<br>
od195307/2020_2021 : Providing and fixing / holding sinages, sign board made of compact aluminium panel sheet or HPL sheet of approved shade , providing 3mm vinyl pased letters with multi language (engilsh & malayalam) and logos of approved sizes, providing side hangers fixing in position,providing centre handers using Ms rods amn chains etc. displaying scope of services, room numbers, doctors rooms, HOD rooms, floor wise facilities ,radiation sinages, mandatory notification as directed by the engineer in charge with one side lettering for fixed in wall and both sides as in projected type etc. complete to detailed pre approved plan.<br>Passages handing types -60x15cm -both side <br>
od195308/2020_2021 : Providing and fixing / holding sinages, sign board made of compact aluminium panel sheet or HPL sheet of approved shade , providing 3mm vinyl pased letters with multi language (engilsh & malayalam) and logos of approved sizes, providing side hangers fixing in position,providing centre handers using Ms rods amn chains etc. displaying scope of services, room numbers, doctors rooms, HOD rooms, floor wise facilities ,radiation sinages, mandatory notification as directed by the engineer in charge with one side lettering for fixed in wall and both sides as in projected type etc. complete to detailed pre approved plan.<br>Name board rooms -60x15cm - one side<br>
od195674/2020_2021 : Providing acrylic LED multi language letter (engilsh & malayalam) letter singaes on the building using three dimensional acrylic channel LED lighting with high bright BGST 0.92 watt water peoof neutral white (280 K) LED modules as per detailed and approvd drawing including minimum 5 year varenty including lighting , placing in position and securing the sinages etc. as per the direction of engineer in charge.<br>
16.59.1 : Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC: 67- 2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class-2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x 5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours). Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-Charge.Mandatory / Regulatory sign boards of 900 mm diametre with support length of 3750 mm
16.59.2 : Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC: 67- 2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class-2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x 5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours). Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-Charge.Cautionary / warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm
16.61 : Providing Retro - reflective regulatory sign board of size 900 mm diameter made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro reflective sheeting as approved by Engineer-in-Charge. Letter, symbols, borders etc. will be as per IRC. 67 with required colour scheme on the boards and with the high intensity grade A. The aluminium sheet to be riveted to M.S. frame of M.S. angle 50x50x4 mm , 4 m long welded to the frame with adequate anti-theft arrangement. Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat ( primer ) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer- in-charge .
DEE VEE PROJECTS LIMITED
KMV Projects Limited
MARYMATHA INFRASTRUCTURE PVT LTD
Bidder Name
MARYMATHA INFRASTRUCTURE PVT LTD
DEE VEE PROJECTS LIMITED
KMV Projects Limited
Malani Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.07 MB
Download all tender documents and submit your bid