Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC | L1 | Accepted-AOC QUOTED RATES WERE INCLUSIVE OF GST HENCE CONTRACT WAS AWARDED ACCORDINGLY TO L1 BIDDER | |
| 2 | Rejected-Technical | - | Rejected-Technical Non-Responsive |
Tender Value
₹10.7 L
EMD Value
₹20,000
Closing Date
26 Aug 2021, 12:00 pmClosed
CGM PPandD
AEGCL, 1st Floor, Bijulee Bhawan
Preparation of Master Plan for Two (2) nos. of Grid Substations under AEGCL
2021_AEGCL_22370_1
AEGCL/MD/AIIB/Master Plan(2)/2021/Bid/R
Open Tender
Consultancy
Works
90 days
Guwahati
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹20,000
Yes
3 Mar 2022
5 Aug 2021
27 Aug 2021
5 Aug 2021
26 Aug 2021
5 Aug 2021
Amount
Construction of two (2) nos. of permanent RCC benchmark pillars at suitable locations - all future references shall be obtained from them. Size of the pillar should be minimum 300mm X 300 mm HFL & FGL markings should be shown in the benchmark pillar.
400/220kV - 2X500 MVA GIS, 220/132kV - 1X160 MVA GIS, 132/33kV - 2X50 MVA AIS at Rangia.
400/220 kV, 2X500 MVA (GIS) at Sonapur with Connectivity to existing 220/132/33 kV - 2X100 MVA Sonapur GIS.
Survey of the entire land area of the GSS in 5 m X 5 m grid marking with RL using total station and submit on AutoCAD, scaled drawing and marking by peg on the field. **
400/220kV - 2X500 MVA GIS, 220/132kV - 1X160 MVA GIS, 132/33kV - 2X50 MVA AIS at Rangia.
400/220 kV, 2X500 MVA (GIS) at Sonapur with Connectivity to existing 220/132/33 kV - 2X100 MVA Sonapur GIS.
Bay Extension at existing 132/33 kV Nalbari SS
Marking the switchyard including cable trench, control room, incoming and outgoing feeders, etc on AUTOCAD scaled drawing and marking by peg on the field. **
400/220kV - 2X500 MVA GIS, 220/132kV - 1X160 MVA GIS, 132/33kV - 2X50 MVA AIS at Rangia.
400/220 kV, 2X500 MVA (GIS) at Sonapur with Connectivity to existing 220/132/33 kV - 2X100 MVA Sonapur GIS.
Planning and marking of staff quarters , guest house, internal roads, drainage system, storm water management etc. on AUTOCAD drawing **
400/220kV - 2X500 MVA GIS, 220/132kV - 1X160 MVA GIS, 132/33kV - 2X50 MVA AIS at Rangia.
400/220 kV, 2X500 MVA (GIS) at Sonapur with Connectivity to existing 220/132/33 kV - 2X100 MVA Sonapur GIS.
Planning and marking on AutoCAD drawings about street lighting , boundary wall and security post, security fencing illumination etc **
400/220kV - 2X500 MVA GIS, 220/132kV - 1X160 MVA GIS, 132/33kV - 2X50 MVA AIS at Rangia.
400/220 kV, 2X500 MVA (GIS) at Sonapur with Connectivity to existing 220/132/33 kV - 2X100 MVA Sonapur GIS.
Planning , estimation and marking on AutoCAD drawings about boundary wall and gate with details of entire colony **
400/220kV - 2X500 MVA GIS, 220/132kV - 1X160 MVA GIS, 132/33kV - 2X50 MVA AIS at Rangia.
400/220 kV, 2X500 MVA (GIS) at Sonapur with Connectivity to existing 220/132/33 kV - 2X100 MVA Sonapur GIS.
Preparing a Proper Substation Layout Drawing to scale along with SLD, Plot Plan Layout, Section drawing, DSLP calculation & drawing clearly specifying the schemes on AutoCAD
400/220kV - 2X500 MVA GIS, 220/132kV - 1X160 MVA GIS, 132/33kV - 2X50 MVA AIS at Rangia.
400/220 kV, 2X500 MVA (GIS) at Sonapur with Connectivity to existing 220/132/33 kV - 2X100 MVA Sonapur GIS.
Bay Extension at existing 132/33 kV Nalbari SS
Preparation of BoQ
400/220kV - 2X500 MVA GIS, 220/132kV - 1X160 MVA GIS, 132/33kV - 2X50 MVA AIS at Rangia.
400/220 kV, 2X500 MVA (GIS) at Sonapur with Connectivity to existing 220/132/33 kV - 2X100 MVA Sonapur GIS.
** HFL & FGL: Should be marked in the master plan(s).
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .