Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | BAPATLA | ANDHRA PRADESH | 504214 | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹1.9 L+₹1,880 (0.98%)Rejected-AOC FLAT NO S 4 DOOR NO 10 4 107 17 SRINIVASA TOWERS SRI RAMNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹2.0 L+₹6,750 (3.54%)Rejected-AOC | L3 | Rejected-AOC Not being L1 |
Tender Value
₹2.3 L
EMD Value
₹4,600
Closing Date
22 Feb 2024, 6:00 pmClosed
Garrison Engineer Naval Depot
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
UPGRADATION OF EXISTING INTERNAL WIRING IN NEW AJT HAWK STOREHOUSE AT MO V OLD SITE, VISAKHAPATNAM
2024_MES_638381_1
8336GEND/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
Visakhapatnam
Please refer Tender documents.
8 documents required · 8 mandatory
₹300
GE ND VISAKHAPATNAM
₹4,600
Yes
30 Apr 2024
20 Jan 2024
24 Feb 2024
21 Jan 2024
22 Feb 2024
3 Feb 2024
Amount
Schedule 'A' Part -I ( E/M Schedule)
M & L For Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through PVC Conduit concealed in Walls / Roofs / Floors / Ceiling etc. and Modular Type Pressed Metal Flush Box made out of 1mm thick GI Sheet of suitable size and including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light Point controlled by One Switch complete all as specified. [Note- The PVC Conduit to Concealed in wall through cutting,Chassing,Pining in making good surfacing where required and pointing in cement mortar and making good for same unit rates are inculded for same]
Description all as per item No. 1 above but for 5/6Amp switch socket out let, independent board complete all as specified
Description all as per item No. 1 above but for 5/6Amp switch socket out let,same board complete all as specified
Description all as per item No. 1 above but for 15/16Amp switch socket out let, independent with 4.0sqmm copper cable of PVC insulated, unsheathed, multi stranded and 4.0 Sqmm for earth continuity conductor, complete all as specified
Supply and fixing of Socket, 6A - 2/3 pin combined 2 module, 230 volt, multipurpose, complete all as specified.
Supply and fixing of Socket 6A/16A - 2/3 pin combined 2 module, 230 volt,multipurpose, complete all as specified.
Supply and fixing Modular switch 1 way 6A, 1 module single pole complete all as specified and directed by Engr-in-charge.
Supply and fixing Modular switch 1 way 16A, 1 module single pole complete all as specified and directed by Engr-in-charge.
Supply and fixing ceiling rose surface bake lite 65 x 30 mm with 3 terminals complete all as specified and directed by Engr-in-charge.
S & F Square recessed mounted LED light (2'x2') of minimum 3600 Lumens (36W) warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F Building Security light LED type of minimum 3500 Lumens (35 Watt) Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 40mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing of Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), TPN, 415 volt, 4 Way, IP-42 protection with 200 Amp rated bus bar and 4.0 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , complete all as specified.
Supply and fixing of MCCB 4P 16KA 63A , 415 Volt, complete all as specified and directed.
Supply and fixing of MCB 40 Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, , complete all as specified
M&L for sub main wiring with 4 run of 10 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 10 Sq mm drawn through PVC surface/concealed conduict of 25 mm dia, complete all as specified and directed by Engg-in-Charge. (Note: Copper conductor 4 run and one run of copper earth wire along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls if needed and making good the disturbed surface are included in the quoted rate.)
M&L for sub main wiring with two run of 6.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 6.0 Sq mm drawn through PVC surface/concealed of 25 mm dia,complete all as specified and as directed by Engr-in-Charge. (Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the quoted rate.)
M.V.K.ENTERPRISES
KANAKAJYOTHI ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .