| 1.00 | Material and labour for preventive maintenance/servicing of power transformer (outdoor type) of capacities 2 MVA, 3 MVA, and 5 MVA and 2.5 MVA including disconnecting incoming and outgoing connections, ensuring safety isolation, servicing and cleaning of internal parts, checking and tightening all electrical/mechanical connections, performing megger testing (IR values for HV/LV windings & winding-to-earth), checking oil level and condition (visual inspection and BDV test), external inspecting of gaskets and bushings, removing carbon deposits from connections and joints, functional testing of protective relays (Buchholz, Pressure Relief, Temperature gauges), carrying out minor repairs and repair of leakage i.e replacement of gland/change of brass nut/bolts and re-assembling the transformer after repairs,checking of earthing connections, conducting tests, recording all parameters, and preparing a service report, complete all as specified and directed; after servicing cable laid complete to the satisfaction of the Engineer-in-Charge/GE
(a) Voltage ratio test
(b) Magnetization Current Test
(c) Voltage balancing Test
NOTE :- (i) The contractor shall produce test certificate against above tests from ser no (a) to (c) from the certified firm.(ii) The cost of dismantling and assembly is deem to be including.
(iii) work to be carried out by qualified personael to ensure safe and reliable operation. Preventing maint/servicing of transformer will be carried out by any equipment manufacture/certified firm and work to be carried out as per IS recommendations complete in all respect. All test perameter and service report shall be submitted by contractor. | 4 | Each Job | 14,000 ₹56,000 | 11,000 ₹44,000 |
| 2.00 | Dehydration/ filtration of transformer oil of existing transformer installed at site with portable plant to improve the dielectric strength 50 KV during filling after initial filtration including testing of dielectric strength after dehydration at site
NOTE :- (i) All arrengement of DG set of suitable capacity of electric supply for running of dehydration plant, T&P and other items required will be arranged by contractor and deem to be included in the cost of dehydration/filtration and nothing extra on this account will be admissiable. Any damage after filtration shall be solely responsible of Contractor & same shall be repaired without any additional cost. (ii) Dehydration report will be submitted by the contractor. (ii) Tthe result is not desirable payment will not made to the contracor | 5,200 | Ltrs | 35 ₹1.8 L | 14 ₹72,800 |
| 3.00 | Supplying, filling dehydration and filtration of new transformer oil for toping up/replacement of transformer oil having dielectric strength not less than 60 KV(rms) with gap of 2.5 mm all as conforming to IS 335 of 1993 complete all as specified and directed by Engineer-in-Charge. | 1,200 | Ltrs | 180 ₹2.2 L | 175 ₹2.1 L |
| 4.00 | Material and labour for replacement of worn out bushing rod made out of brass with heavy duty three nuts and three washer at both ends suitable for HV side all as per IS 3347-5-2 (1979) shape, dia and length suitable for 2 MVA to 5 MVA capacity transformers :- | 2 | Each | 1,500 ₹3,000 | 1,200 ₹2,400 |
| 5.00 | Material and labour for replacement of worn out bushing rod made out of made out brass with heavy duty with nuts and washer at both ends suitable for LV side all as exiting size, shape and length suitable for 2 MVA to 5 MVA transformers :- | 2 | Each | 1,300 ₹2,600 | 1,500 ₹3,000 |
| 6.00 | Material and labour for replacement of worn out porcelain bushing for 33KV side indoor /outdoor transformers with rubberised cork sheet washers 4mm thick all as required at site and as directed by engineer in charge suitable for 2 MVA to 5 MVA capacity transformers:- | 2 | Each | 1,200 ₹2,400 | 1,000 ₹2,000 |
| 7.00 | Material and labour for replacement of worn out porcelain bushing for 11KV side indoor /outdoor transformers with rubberised cork sheet washers 4mm thick all as required at site and as directed by engineer in charge suitable for 2 MVA to 5 MVA capacity transformers:- | 2 | Each | 1,200 ₹2,400 | 1,200 ₹2,400 |
| 8.00 | Material and labour for replacement of worn out rubberised cork sheet 4 mm thick for transformer top cover all as required at site and as directed by engineer in charge suitable for 2 MVA to 5 MVA capacity transformers. | 2 | Each | 950 ₹1,900 | 850 ₹1,700 |
| 9.00 | M & L for Preparation of old surface of transformer for painting externally including fins/radiators removal of all rust/oil/grease and unwanted material and then two coats of synthetic enamel metallic paint by means of spray gun at site of installation of transformer alongwith writing SM No complete all as specified and directed by engineer in charge suitable for 2 MVA to 5 MVA capacity of transformer. | 1 | Each | 1,500 ₹1,500 | 3,000 ₹3,000 |
| 10.00 | Material and labour for replacement of worn out silica gel breather assembly including silica gel all as per existing sample suitable for 2 MVA to 5 MVA capacity of transformers of any make. | 1 | Each | 1,500 ₹1,500 | 1,500 ₹1,500 |
Updated dates
Tender Value
₹13.3 L
EMD Value
₹26,580
Closing Date
10 Jan 2026, 6:00 pmClosed
CWE No.2 Meerut
Headquarters Commander Works Engineer No 2 Military Engineer Services Boundary Road, Near Supply Depot Meerut Cantt-250001
REPAIR/ MAINT OF POWER TRANSFORMERS AND VCBS INCLUDING ALLIED WORKS AT 33 KV MAIN RECEIVING SUB STATION ROORKEE UNDER GE ROORKEE
2025_MES_734243_3
95396/RKE/E8
Open Tender
Civil Works
90 days
Roorkee
Please refer tender pages
9 documents required · 9 mandatory
₹500
GE Roorkee
₹26,580
12 Feb 2026
20 Dec 2025
12 Jan 2026
20 Dec 2025
10 Jan 2026
27 Dec 2025
Material and labour for preventive maintenance/servicing of power transformer (outdoor type) of capacities 2 MVA, 3 MVA, and 5 MVA and 2.5 MVA including disconnecting incoming and outgoing connections, ensuring safety isolation, servicing and cleaning of internal parts, checking and tightening all electrical/mechanical connections, performing megger testing (IR values for HV/LV windings & winding-to-earth), checking oil level and condition (visual inspection and BDV test), external inspecting of gaskets and bushings, removing carbon deposits from connections and joints, functional testing of protective relays (Buchholz, Pressure Relief, Temperature gauges), carrying out minor repairs and repair of leakage i.e replacement of gland/change of brass nut/bolts and re-assembling the transformer after repairs,checking of earthing connections, conducting tests, recording all parameters, and preparing a service report, complete all as specified and directed; after servicing cable laid complete to the satisfaction of the Engineer-in-Charge/GE (a) Voltage ratio test (b) Magnetization Current Test (c) Voltage balancing Test NOTE :- (i) The contractor shall produce test certificate against above tests from ser no (a) to (c) from the certified firm.(ii) The cost of dismantling and assembly is deem to be including. (iii) work to be carried out by qualified personael to ensure safe and reliable operation. Preventing maint/servicing of transformer will be carried out by any equipment manufacture/certified firm and work to be carried out as per IS recommendations complete in all respect. All test perameter and service report shall be submitted by contractor.
Dehydration/ filtration of transformer oil of existing transformer installed at site with portable plant to improve the dielectric strength 50 KV during filling after initial filtration including testing of dielectric strength after dehydration at site NOTE :- (i) All arrengement of DG set of suitable capacity of electric supply for running of dehydration plant, T&P and other items required will be arranged by contractor and deem to be included in the cost of dehydration/filtration and nothing extra on this account will be admissiable. Any damage after filtration shall be solely responsible of Contractor & same shall be repaired without any additional cost. (ii) Dehydration report will be submitted by the contractor. (ii) Tthe result is not desirable payment will not made to the contracor
Supplying, filling dehydration and filtration of new transformer oil for toping up/replacement of transformer oil having dielectric strength not less than 60 KV(rms) with gap of 2.5 mm all as conforming to IS 335 of 1993 complete all as specified and directed by Engineer-in-Charge.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
BOQ_834808.xls
BOQ • 0.30 MB
Tender95396.pdf
Tender Documents • 1.38 MB
Download all tender documents and submit your bid