Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAdmitted-Finance KORCHEY PS RAJARAPPA VILL LAWALONG KORCHE RAMGARH JHARKHAND 825101 | RAMGARH | RAMGARH | JHARKHAND | 825101 | ₹4.3 L | L1 | Admitted-Finance |
| 2 | Rejected-Technical AT JHARKHAND 15 NO KEDLA DIST RAMGARH JHARKHAND | RAMGARH | JHARKHAND | 825101 | - | - | Rejected-Technical Technically not accepted |
| 3 | Rejected-Technical LAIYO CHOWK RAMGARH JHARKHAND | RAMGARH | JHARKHAND | 825325 | - | - | Rejected-Technical Technically not acceptedd |
| Sl No | Description | Qty | Unit | M/S SANYUKTA ENTERPRISES L1 |
|---|---|---|---|---|
| 1.00 | Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40
mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required. | 9 | No | 5,960 ₹53,640 |
| 2.00 | Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required. ( 5 X 50 X 0.324 X 3 =243) | 243 | KG | 240 ₹58,320 |
| 3.00 | Supplying and erection of galvanised stay set for 11 KV overhead lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. | 6 | SET | 5,156 ₹30,936 |
| 4.00 | Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. | 2 | No | 1,100 ₹2,200 |
| 5.00 | Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finishpaint as required. | 4 | No | 2,430 ₹9,720 |
| 6.00 | Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ | 7 | NO | 1,156 ₹8,092 |
| 7.00 | Supplying and erection of a set of cross bracing FRLSame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nutsincluding drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required. | 3 | No | 5,920 ₹17,760 |
| 8.00 | Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required. | 7 | No | 673 ₹4,711 |
| 9.00 | Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required. | 6 | no | 250 ₹1,500 |
| 10.00 | Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. | 6 | Nos | 1,000 ₹6,000 |
Tender Value
₹4.9 L
EMD Value
₹6,100
Closing Date
28 Mar 2026, 9:00 amClosed
P(EnM)
KUGP
Replacement of damaged poles strengthening of 3.3KV OH line at KUGP under h.bagh Area
2026_CCL_356896_1
PO/KUGP/EnM/Tender/25-26/12
Open Tender
Electrical and Maintenance Works
30 days
KUGP
AS PER NIT
2 documents required · 2 mandatory
₹6,100
30 Apr 2026
17 Mar 2026
30 Mar 2026
18 Mar 2026
28 Mar 2026
18 Mar 2026
18 Mar 2026 - 23 Mar 2026
Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required.
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required. ( 5 X 50 X 0.324 X 3 =243)
Supplying and erection of galvanised stay set for 11 KV overhead lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finishpaint as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/
Supplying and erection of a set of cross bracing FRLSame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nutsincluding drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supply of 8 SWG wire
Erection of hexagonal type guard as required. (01 X 50 X 0.151 X 3 = 22.65)
Erection of G.I. Wire No. 8 SWG including binding etc. as required. (05 X 50 X 0.151 X 01 = 37.75)
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Dismantling of over head lines comprising of copper/ aluminiumover head conductor, G.I. wire, cross arms, insulators etc. as required. ( 5 X 50 X 1.03 X 0.324 X 3 =250.29) (Crossarm 9 X 1 X 7.14 =64.26) (insulator 24 X 0.5=12) 250.29 +64.26 +12 = 326.55
Supplying and Fixing of lighting arrestor five spike 11KV.
Supplying and Fixing of post insulator 11KV.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Clamps, bolts, nuts etc.
Pole painting.
Providing and laying GI tape 32 mm X 6 mm from earth electrode directly in ground as required.
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.85 MB
BOQ_369753.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid