| 1 | L1₹41.6 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹44.0 L+₹2.5 L (5.93%)Rejected-AOC HQ CWE AHMEDABAD | GANDHINAGAR | GUJARAT | 382006 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹45.2 L+₹3.6 L (8.70%)Rejected-AOC 13 THAKKAR PLOT DEEPAK KUNJ PORBANDAR 360575 | PORBANDAR | GUJARAT | 360575 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹45.3 L+₹3.7 L (8.86%)Rejected-AOC KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹45.5 L+₹4.0 L (9.55%)Rejected-AOC HQ CE SC PUNE | PUNE | MAHARASHTRA | 410301 | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹77,000
Closing Date
3 May 2022, 6:00 pmClosed
GE I CG Porbandar
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
PROVISION OF WATER LEVEL INDICATOR FOR OHT AND UG SUMP AND DEDICATED WATER SUPPLINE FROM EXISTING PUMP HOUSE TO PROPOSED SWIMMING POOL AT CGDHQ-15 OKHA UNDER GE I CG PORBANDAR
2022_MES_515918_2
8734
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Okha
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE I CG PORBANDAR
₹77,000
Yes
25 May 2022
27 Apr 2022
4 May 2022
27 Apr 2022
3 May 2022
27 Apr 2022
Amount
SCHEDULE 'A'
Supply and Fix Air termination, single pointed, copper rod 12mm dia and 300mm long
M&L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw
M&L Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground
M&L for earthing complete with galvanized steel earth plate electrode including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth strip 4mm mm by means of bolts nuts check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES SSR Part-1 connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanized iron 20 mm dia. light grade pipe and watering pipe shall be 20 mm bore medium grade PCC pit with pre cast RCC cover, charcoal/salt funnel etc. complete all as directed.
Supply and Fix Aviation Obstruction LED Light fitting , IP65, 90volts to 280volts AC 50Hz. including pcc foundation and make necessary arrangement
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out Soft/ Loose soil complete all as specified and directed
Returning filling in incl spreading levelling watering and well Ramming in layers not exc 25 cm thick complete all as specified and directed
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
Supply, Fix and testing Smart Digital 10-levels % Indicator stage type with mechanism to detect & display the Water level in an Underground/Overhead tank., corrosion & maintenance free Magnetic sensors Buzzer alarm sounds on Low & High Levels. Including necessary fittings
Supply and layiing 3 Core Copper Tinned Wire & corrsion free Sensors cable
Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 ( Part I and II) for protection of underground calbes of size 50 mm Inner dia with all fittings. laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified (excavation and earth work shall be measured and paid separately) Make: Rex/Poly/Gemini
S &F MCB (DB) SPN 4 way double door 415 V made of sheet metal enclosure for MCB's as incomming and SPN/SP MCB as outgoing as spoecified Make: Hager / Legrand/ schneider
M&L for MCB SPN pole 240 volt C curve 10 KA,ISI marked as per IS/IEC 60898-1 2002 of 16/32 Amps capacity IP 20 complete all as specified and directed
M&L for MCB SP 240 volt C curve 10 KA,ISI marked as per IS/IEC 60898-1 2002 of 6/32 Amps capacity IP 20 complete all as specified and directed
M & L submain wiring with two runs of 1.5 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLS 1100 volts grade cable drawn through and including PVC conduit and one run of 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade cable as earth conductor in concealed/surface casing caping but shall be increased as per actual site requirement in accordance with clause No. 19.125 of SSR Part-I) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling etc complete complete as specified.
M & L submain wiring with two runs of 2.5 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLS 1100 volts grade cable drawn through and including PVC conduit / PVC Casing caping and one run of 2.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade cable as earth conductor in concealed/surface casing caping but shall be increased as per actual site requirement in accordance with clause No. 19.125 of SSR Part-I) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling etc complete complete as specified.
Supply and lay pipe ductile Iron , S/S including specials, Class “K-7” ,100 mm (4”) dia
Supply and lay pipe ductile Iron , S/S including specials, Class “K-7” ,150 mm (6”) dia
Material and Labour for DI fittings and fixtures Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 150mm bore.
Supply and installed testing and commissioning monoblock pump set , electric drivern 3 phase, 415 V (+10 or -10),3000 RPM, suction/discharge 100 mm CI/Bronze impeller of head range 6-16 m, discharge 32.8-12.5 LPS capacity including installation , etc. complete all as directed by Engr in charge. Make :- Kirloskar / Lubi / crompton
Supply and fix DOL Starter for pump for up to 05 HP motor, 415 V, 3 Phase, 50 Hz, including lugs and necessary fixture of cable connection complete all as directed by Engr in charge
Supply and lay pipe galvanized, “Heavy class”, including fittings, 80 mm (3”) dia.
Supply and fix Valve, reflux,NRV with by-pass Arrangement, 80 mm (3”) dia.
Supply and fix Valves, Sluice, flanged of class 1.6 PN ,150 mm (6”)dia.
Supply and fix Valve, butterfly conforming to IS 13095,80 mm (3”) dia.
Supply and fix Valves, Sluice, flanged of class 1.6 PN ,100 mm (4”)dia.
roxy enterprise
OM ENGINEERING
JAY BHARAT METAL SUPPLIERS
K B N TRADERS
K K Construction Co
M/s SK Traders
SURESH ELECTRICALS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .