Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.7 LAccepted-AOC DOOR NO 10 89 BC COLONY PAPAYYARAJUPALEM SUJATHANAGAR VISAKHAPATNAM 530 051 | VISAKHAPATANAM | ANDHRA PRADESH | 530051 | ₹48.7 L | L1 | Accepted-AOC Admitted |
| 2 | L2₹49.6 L+₹92,307.24 (1.90%)Rejected-AOC | ₹49.6 L+₹92,307.24 (1.90%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹50.0 L+₹1.3 L (2.62%)Rejected-AOC | ₹50.0 L+₹1.3 L (2.62%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹50.4 L+₹1.7 L (3.56%)Rejected-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | ₹50.4 L+₹1.7 L (3.56%) | L4 | Rejected-AOC Rejected |
| 5 | L5₹51.0 L+₹2.3 L (4.78%)Rejected-AOC | ₹51.0 L+₹2.3 L (4.78%) | L5 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | ASHA KIRAN CONSTRUCTIONS L6 | MEGHANAENTERPRISES L3 | PRASAD INFRAS L4 | M/s KAMADHENU ENGINEERING CONSTRUCTIONS L1 | Y RAMESH L2 | NAVEEN INFRASTRUCTURES L5 | prasad constructions L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| .01SCHEDULE 'A' PART-I: B/R WORKS | ||||||||||
| 1.00 | Excavation over area, n exe 1.5m deep and getting out in soft and loose soil | 37.95 | Cum | 252 ₹9,563.4 | 225 ₹8,538.75 Lowest | 260 ₹9,867 | 239 ₹9,070.05 | 242 ₹9,183.9 | 245 ₹9,297.75 | 250 ₹9,487.5 |
| 2.00 | Excavation over area for each additional 1.5m or part hereof in depth beyond the first 1.5m | 8.06 | Cum | 335 ₹2,700.1 | 335 ₹2,700.1 | 360 ₹2,901.6 | 329 ₹2,651.74 Lowest | 331 ₹2,667.86 | 330 ₹2,659.8 | 350 ₹2,821 |
| 3.00 | Excavating in trenches n.exe. 1.5 m width and n.exe. 1.5 m in depth for foundation in soft/loose soil & getting out. | 17.64 | Cum | 330 ₹5,821.2 | 335 ₹5,909.4 | 330 ₹5,821.2 | 329 ₹5,803.56 Lowest | 333 ₹5,874.12 | 335 ₹5,909.4 | 340 ₹5,997.6 |
| 4.00 | Returning filling in , including spreading,levelling,watering & well ramming in layers not exc 25 cm. | 26.15 | Cum | 130 ₹3,399.5 | 135 ₹3,530.25 | 129 ₹3,373.35 | 122 ₹3,190.3 Lowest | 124 ₹3,242.6 | 126 ₹3,294.9 | 145 ₹3,791.75 |
| 5.00 | Removing excavated material n exc 50 m & depositing where directed at a level n exc 1.5 m. | 19.86 | Cum | 330 ₹6,553.8 | 310 ₹6,156.6 Lowest | 315 ₹6,255.9 | 320 ₹6,355.2 | 321 ₹6,375.06 | 330 ₹6,553.8 | 350 ₹6,951 |
| 6.00 | Demolition of un- reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level) | 1.08 | Cum | 950 ₹1,026 Lowest | 980 ₹1,058.4 | 990 ₹1,069.2 | 959 ₹1,035.72 | 969 ₹1,046.52 | 1,000 ₹1,080 | 1,100 ₹1,188 |
| 7.00 | M&L for Plain Cement Concrete Type C2 1:3:6 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete | 4.8 | Cum | 4,600 ₹22,080 | 4,600 ₹22,080 | 4,750 ₹22,800 | 4,550 ₹21,840 Lowest | 4,569 ₹21,931.2 | 4,600 ₹22,080 | 4,700 ₹22,560 |
| 8.00 | M&L for M30 RCC design mix using 20 mm graded aggrete for raft foundation footing ,bases of columns, plinth beams , piles and pile caps & mass concrete. | 18.78 | Cum | 7,800 ₹1,46,484 | 7,500 ₹1,40,850 Lowest | 7,690 ₹1,44,418.2 | 7,700 ₹1,44,606 | 7,760 ₹1,45,732.8 | 7,800 ₹1,46,484 | 7,900 ₹1,48,362 |
| 9.00 | M&L for M30 RCC design mix using 20 mm graded aggrete for columns, pillars,posts and struts. | 12.63 | Cum | 9,600 ₹1,21,248 | 9,400 ₹1,18,722 Lowest | 9,600 ₹1,21,248 | 9,500 ₹1,19,985 | 9,530 ₹1,20,363.9 | 9,600 ₹1,21,248 | 9,700 ₹1,22,511 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
10 Oct 2025, 6:00 pmClosed
Garrison Engineer Naval Depot
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
PROVISION OF ARMAMENT PREPARATION SHED AT INAS 551 P116 AT INS DEGA VISAKHAPATNAM
2025_MES_731498_1
8522/gend/E8
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ND VISAKHAPATNAM
₹92,000
Yes
6 Jan 2026
18 Sept 2025
13 Oct 2025
18 Sept 2025
10 Oct 2025
3 Oct 2025
Amount
SCHEDULE 'A' PART-I: B/R WORKS
Excavation over area, n exe 1.5m deep and getting out in soft and loose soil
Excavation over area for each additional 1.5m or part hereof in depth beyond the first 1.5m
Excavating in trenches n.exe. 1.5 m width and n.exe. 1.5 m in depth for foundation in soft/loose soil & getting out.
Returning filling in , including spreading,levelling,watering & well ramming in layers not exc 25 cm.
Removing excavated material n exc 50 m & depositing where directed at a level n exc 1.5 m.
Demolition of un- reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level)
M&L for Plain Cement Concrete Type C2 1:3:6 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete
M&L for M30 RCC design mix using 20 mm graded aggrete for raft foundation footing ,bases of columns, plinth beams , piles and pile caps & mass concrete.
M&L for M30 RCC design mix using 20 mm graded aggrete for columns, pillars,posts and struts.
M&L for M30 RCC design mix using 20 mm graded aggrete for beams, cantilevers, lintels over 1.5 m span.
M & L for TMT reinforcement 10 mm dia and over cut to length bent to shape including cranking, hooking etcbinding with mild steel wire not less than 0.90 mm dia (annealed) all as directed complete.
S & F mild steel TMT bar 5 mm dia and over upto and including 10mm dia in strrups as in including cutting, bending and binding with mild steel not less than 0.9 mm dia (annealed) all as directed complete.
Form work for foundation footing , bases of columns &plinth beams similar work vertical or batter.
Form work for side of pillars, posts, columns & similar works vertical or batter.
Form work to side & soffits of floor or roof beams lintels & similar works.
M&L for brick work with flyash bricks straight or curved on plan exc 6 m mean radious built in cement mortar 1:6
M&L 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:6, finished even & smooth without using extra cement
M&L 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even & smooth without using extra cement
S&F anodised power coated frame for doors, windows, ventilators and partion with one or more rebates including joining cleat for fixing etc complete all as specified in cl power coating above aluminium section.(minimum thickness of poweder coating 50 micron).
S&F power coated aluminium door shutters aluminium section weighing 0.55 kg/m including necessary joining cleats glazing clips rubber neoprene packing anodised aluminium snap beading screws etc complete all as specifid power coating of any colour(thickness of power coating not less than 50 micron.
Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified.
S & F 4.8 mm thick Sheet glass, ordinary quality and glazing with wooden beads in squares exceeding 0.5 Sqm in each pane
M&L 12 mm thick prelaminated particle boards exterior grade prelaminated both sides with decoratative choice lamination fixed in alum frame work.
S&F for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre incl Hangers 4 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
S&F for 8 mm thick Exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) complete all as specified and as directed.
M& L for Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc of Fe 410-W(GdeE- 250) qualityA complete all as specified and directed
M&L for Fe 410-W(GdeE- 250) quality A MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment.
M&L MS rolled section of grade Fe-410-0 or Fe-310-0 (beam, tee, angle channel ot flat section) as in roof trusses (framed), trussed purlins, crane gantries rails, and fastening and heavy bracket framing including destance pieces, wind tie, cleats etc. and one coat of zinc chromate primer plaint complete all as specified and directed.
S&F mild steel screw bolts with hexagonal or square heads at one end and screwed the other and screwed end to be fitted with washers, one nut exc 45cm long and dia of neck exc 12mm & n.exc 20mm
S&F pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.
M&L for Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and directed.
M&L for providing flow applied epoxy resin based flooring of 4mm total thickness with 2mm thick high strength self smoothing under lay with three compound system comprising of epoxy resin base, resin hardner & filler Nitofloor EU5 of M/s Fosroc or equivalent approved make as specified here in after and floor topping with self-smoothing epoxy polyurethane 2 mm thick NitoflorEPU2000 of M/s Fosroc or equivalent approved make as specified here in after ) over a coat of solvent based Epoxy Resin Primer Nitoprime 25 designed for maximum absorbtion and adhesive to concrete substrate on existing floor by using stiff brushes and/or rollers for primer and serrated trowels and spiked nylon rollers for finishing coat including preparation of existing flooring cut open all anchor grooves along floor topping termination points , all crackes in the floor concrete preparing the surface of concrete substrate with scarification or by suitable mechanical means and cleaning the surface with industrial vaccume cleaner to remove all foreign matter , dust and debris etc including filling the cut open grooves with same material , finishing the surface to even and plain surface using suitable means to remove all imperfections , trowel marks and entrapped air complete all as specified as directed and as per manufacturer's instructions. Note: The work shall be executed by the Authorised Applicator of the manufacturer under the guidance of manufacturer of epoxy flooring .Make: M/s Fosroc chemicals India (P) Ltd or M/s STP Ltd or M/s BASF India Ltd.
M&L for two coats of synthetic enamel paint on new steel surface exc 10 cm width or girth on 01 coat of primer (Red oxide Zinc chrome) incl preparation of new surfaces complete.
Preparation of New or previously untreated surfaces of cement or plastered surfaces, of any description and girth, not otherwise described and applying 3mm thick wall care putty and primer on wall surface to achieve even and smooth surface and applying two coats of oil bound distemper on walls.
Material & Labour for applying wall care putty of 1mm thick over plastered surface to prepare the surface even and smooth and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
M&L hard core of broken stone or boulders of guage not exc 63mm but n exc 40mm deposited spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete.
SCHEDULE 'A' PART-II: E/M WORKS
Supplying, installing testing and commissioning of Analogue Addressable type Single Loop Fire Alarm Control Panel with 99 detectors & 99 Modules & up to 200 Detectors and Modules per each loop, expandable Up to 1000 fire detection zones, with UL/ULC/ LPCB/ FM listed and complying with BS EN 54 Parts 2 and 4 along with Network interface Card and Lead Acid Battery backup for 08 Hours normal operation and 15 minutes alarm operation, the control panel, battery charger including provision of protective cover as and where required and taking down existing old panel of any description and type complete all as specified and as directed and consistiong of lthe following features:-
Note: The rate quoted shall also deemed to include for the following provisions also:- [i] Supply and installation of Batteries 12v 18/07 Ah - 02 Nos [ii] Supply and installation of 24 volt Fault Torrent Network card/ OLYNET/ ONERING with bulit in diagnostics and is fully monitored for both short and open circuit faults between nodes installed in fire alarm panel with maximum 200 Network nodes. [iii] Fire detection and alarm system connected with Compatible GSM/PSTN auto dialer alongwith activated Sim for easy communication with pre recorded messages to stored phone numbers - 1 Set Make: Compatible with Honeywell, Notifier, Apollo Discovery, Argus Vega, Hochiki ESP and Nittan Evolution protocols
Supply, fix and testing of Addressable single action manual call point, resettable type, having integrally mounted addressable module to monitor and report contact status complete all as specified and as directed.
Supplying, installing and testing of Multisensor Detector with self built intelligence Complying with and type certified to EN 54 and conforming to IS - 11360 comprising of optical smoke and thermistor temperature sensors, to give both combined signal as well as a separate heat signal for improved false alongwith isolator modules as required, provided as per area requirment below or above the false ceiling including taking down old detectors of andy descrition and type complete all as specified and as directed by engg in charge
Supply and installation of UV Flame Detector with air Purging provision, Flickering LED indication for normal operation 24V DC, 4 Wire system with IHMB01XY complete all as specified and as directed.
Supply & Installation and Commissioning of switch monitor module to be installed between every 20 nos. of devices to isolate the circuit from single short circuit on the analogue addressable loop cable, this is non addressable device with yellow LED for status indications, including all accessries all as specified and directed by Engr-in-Charge
Supplying, installing and testing of Addressable electronic loop sounder cum strobe alongwith in-built isolators complete all as specified and as directed.
Supply, lay, test and commissioning of 2 Core, 1.50 Sq.mm, PVC Insulated and PVC sheathed, heavy duty cable, ISI marked with Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked complete all as specified and as directed.
Supply and Laying of 20mm Stove enamelled rigid steel conduit for Surface area Including Bends, Junction Boxes,couplings, Base Saddles, Screws Etc all as specified and directed by Engr-in-Charge
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2.0 KVA
Supply, Installation erection, testing and commissioning of indoor type heavy duty single grider hand operated traveling (HOT) overhead crane, capable of handling 1.0 tonne main hoist with Span of 08-09 metres (exact dimension should be measured after installation of girders on both side of walls by B/R) , with height of lift 4-5 meter, single box girder type main gantry girder with necessary steel supporting structure and crab with clear hook height of 4-5 metres from the floor of corridor all as specified complete with all assessories/equipments and painted all as per OEM specification as approved by Accepting officer. HOT crane shall be provided with the following specifications and capable for Hand operating movements: (i) Longitudinal travel shall be limited to 0.5 m away from the walls on both ends. (ii) HOT crane shall be provided with the longitudional ,transverse and up & down movements (iii) Capacity of crane : 1.0 Tonne single girder (iv) Clear Span : 08-09 Mtr approx. (v) Bay lengh : 10 Mtr approx (vi)Llift height : 4-5 Mtr from the floor, C hook with swiveling lockand safety latch
NOTE 1:- (a) The crane shall be tested stage wise for 25%, 50%, 75%,100% (full load) and 25% overloadis to be carried out. All materials and manpower required for the testing arrangements is deemed to be included in the quoted rate and nothing extra is admissible. (b) Guard shall be provided all along the length with approach ladders on both the sides of crane with hand rail on both the sides of ladder at a suitable level and the ladders should have landing platforms at every 4 to 5m or less . (c) Clear span and bay length specified and shown on building are only indicative. The tenderer shall visit the site and as certain exact span and bay length before quoting the rates. (d) Gantry rail made up of 50 mm square bar duly welded to ISMC beam longitudinally including painting with 2 coats of epoxy paint over red oxide primer all as specified deemed to be included in quoted rate. (e) Dimensions,capacities/sizes of equipments/ accessories mentoned on drawing are minimum to be provided. Prior approval of Accepting Officer shall be obtained for the detailed construction drg of HOT crane and the rates quoted above shall deemed to include such provisions and its accessories before execution of work.
(f) The crane should be manufactured as per latest IS standard and safety factors. The final drawing and design of the crane shall be got approved from IIT / NIT and shall be submitted to Accepting Officer before manufacturing of the crane.
(g) Any technical clarifications regarding size, capacity, rating and specification and drawings may please be clarified by the bidder from the E-4 section of HQ CWE(V) before the Bid is submitted, he should also visit the site where the crane are being installed before submitting the Bid. Note 2-Gaurds will be provided with approch ladder on both sides of Long traval at a suitable level and ladders should have landing paltforms at both end with guards and side railing. Note 3- Mechanical stopper will be provided on both side of Main Girder as per manufacturer recommendation. Note 4- If Any work not specified above, but considered necessary for efficient installation , working and performance of HOT Crane Shall be deemed to be included in quoted rate.
S & F MCCB Enclosure Box suitable for 63 to 250 Amps outdoor type, IP 65 rating including all accessories for connecting MCCB and Cables complete all as specified by Engr-in-Charge.
S & F in repairs MCCB 3 / 4 Pole, 125 Amps, 50 Hz, 16KA, 415 Volts,adjustable thermal and fixed magnetic type with all necessary aluminium lugs and glands, etc complete all as specified and as directed.
Supply lay and testing of cable in trenches/walls XLPE insulated, armoured electric cable (heavy duty 1100volt grade with stranded aluminium conductor of size 25sqmm 4.0 core complete all as specified and directed by Engr-in-charge.
Excavation in trenches not exc.1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil for laying of cable complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified
Removing excavated surplus soils meterial not exc.50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
Material and labour for natural river sand as cushioning of cables, including spreading and punning down complete all as specified and directed by Engineer in charge. Note : punned thickness shall be measured for payment purpose
Supply and laying in trenches bricks common burnt clay building brick , sub class B designation 75 complete all as specified & directed
Supply and laying GI tubing lingh grade 40mm in trenches complete all as specified & directed by Engr in charge
M&L Earthing complete with GI plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with GI earth wire of 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber,CI frame with CI 10mm thick cover, 20mm dia GI medium grade pipe for watering , and water funnel with wirw mesh, 20mm dia light grade GI pipe for protection of strip complete all as specified and testing on completion.
M & L for point wiring of 1.5 Sqmm PVC insulated and stranded copper cable 1100V, FRLS grade multistranded drawn in and including 20mm PVC conduit / casing caping /concealed PVC conduit on/in walls/ceiling with tee, bend, elbows , junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity including not less than 1.0mm thick prefabricated galvanised boxes with white modular cover plate of suitable module for fixing modular switches, sockets, regulator and connected the earth wire to common earth dolly for One light /controlled by one switch Note:-(i) The quoted rate shall includes all the cost of cutting, chasing, cementing work and making all the disturbed surfaces of wall / ceiling good to match the existing wall / ceiling along with same colour.
S & F in Modular switch 1 way 6A, 1 module single pole complete all as specified and directed by Engr-in-charge.
Material and labour in repairs for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in and including 25mm surface stove enamel steel conduit on walls/ceiling with tee, bend, elbows,junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity suitable for flame proof switches, sockets regulator and connected the earth wire to common earth dolly for One light point/fan point controlled by one switch complete all as specified and as directed.
Description all as per item No. 59 above but for 5 Amp flame proof switch socket out let, independent with 1.5 sqmm copper cable of PVC insulated, unsheathed, multi stranded and 1.5 Sqmm for earth continuity conductor, complete all as specified and directed.
Description all as per item No. 59 above but for 15/16Amp flame proof switch socket out let, independent with 4 sqmm copper cable of PVC insulated, unsheathed, multi stranded and 4.0 Sqmm for earth continuity conductor, complete all as specified and directed.
S & F in flame proof switch socket and plug combined in LM6 cable termination box in LM6 ,16A 250 volt,2P+earth complete all as specified and directed.
S & F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V, complete all as specified and directed.
S & F flame proof switch socket and plug combined in LM6 cable termination box in LM6 ,25A 250 volt,2P+earth complete all as specified and directed.
S & F in repairs ceiling rose surface bake lite with 3 terminals complete all as specified and directed by Engr-in-charge.
Supply and fix flame proof exhaust fan, steel body AC single Phase. 230V of size 18'' sweep with, blades, and frame and louvers including making suitable hole for fixing Exhaust fan complete all as specified and directed.
Supply and fixing Flame proof ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. complete including testing after completion all as directed by Engineer in charge
Supply and fixing flame proof LED light fitting 100 Watt , CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver,holders,connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed.
S & F in Building Security light LED type of 4500 Lumens (45 W) Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 40mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted incluidng taking down old unsv fittings complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing of Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), TPN, 415 volt, 6 Way, IP-42 protection with suitably rated bus bar and suitable for having MCB’s , complete all as specified and as directed.
Supply and fixing MCB 100 Amp, 415 Volt, TPN, breaking capacity 10 KA 'C' series, complete all as specified and as directed.
Supply and fixing of MCB 6 to 32Amp, 240 Volt, SP, breaking capacity 10 KA 'C' series, complete all as specified and as directed.
Y RAMESH (BID ID -3443648)
MEGHANAENTERPRISES (BID ID -3447188)
PRASAD INFRAS (BID ID -3442508)
NAVEEN INFRASTRUCTURES (BID ID -3447239)
ASHA KIRAN CONSTRUCTIONS (BID ID -3446374)
prasad constructions (BID ID -3443122)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .