Repair and Maintenance works to Kecheri IPS Quarters No 04 Dilkush Compound Thiruvananthapuram
2026_KPHCC_873465_1
NIT No.51/KPHCC/2026-27
Limited
Civil Works - Buildings
Item Rate
14 days
Thiruvananthapuram
Please refer Tender documents.
7 documents required · 7 mandatory
₹590
₹1,800
26 Sept 2026
26 Sept 2026
5 Oct 2026
26 Sept 2026
3 Oct 2026
26 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1WATERPROOFING | |||||
| 1.001 | 14.1.1:Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand) | 10 | sqm | - | - |
| 1.002 | 13.10:15 mm cement plaster 1:3 ( 1 cement :3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall. | 10 | sqm | - | - |
| 1.003 | OD141371/2026-2027:Providing and applying Dr. Fixit Roofseal Classic or equivalent fibre reinforced elastomeric liquid waterproofing membrane with resilient acrylic polymer, over concrete/RCC terrace roof, parapet and sunshade surfaces, including thorough surface preparation by pressure washing at minimum 1400 psi and removal of dirt, dust, loose particles, algae, mould and existing defective coating; cutting and widening visible cracks/joints greater than 0.50 mm into V-groove of approximately 8–10 mm width, cleaning and sealing the same with approved moisture-curing Dr. Fixit PU Sealant/Feviseal HY 100/200 sealant and allowing adequate curing; applying one self-priming coat of Roofseal Classic diluted with water in the ratio 2:1 at approximately 10–11 m²/litre, followed by two coats of undiluted Roofseal Classic at approximately 2–2.2 m²/litre/coat, the second coat being applied perpendicular to the first, to achieve a total dry film thickness of approximately 450–500 microns; coating shall be continued to required vertical surfaces below drip mould and all corners, gaps, joints, outlets and repaired leakage areas shall receive two additional coats. Providing and fixing suitable geotextile reinforcement at corners/junctions wherever required, embedded in the waterproofing coating. The complete treatment shall be carried out as per manufacturer's recommendations and directions of Engineer-in-Charge, including all materials, labour, surface preparation, application, curing and all incidental charges etc complete. | 70.08 | sqm | - | - |
| 1.004 | OD144323/2026-2027:Coolie Labour | 2 | each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.13 MB
Tendernotice_2.pdf
PDF • 0.70 MB
tenderdocument2023.pdf
Tender Documents • 2.25 MB
BOQ_1481833.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .