| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.2 LAccepted-AOC EAST VIVEKANANDA PALLY MANGAL PANDEY SARANI PO RABINDRA SARANI SILIGURI 734 006 WB | JALPAIGURI | WEST BENGAL | 734006 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹40.9 L+₹3.7 L (10.0%)Rejected-Finance RATNA RAJ BUILDING 1ST FLOOR 262 BIDHAN ROAD OPP TERA HOTEL PO SILIGURI 734001 DIST DARJEELING WB | JALPAIGURI | WEST BENGAL | 734001 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹46.4 L+₹9.2 L (24.8%)Rejected-Finance 54 SATYEN BOSE ROAD DESHBANDHUPARA SILIGURI 734 004 | JALPAIGURI | WEST BENGAL | 734004 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹47.7 L+₹10.5 L (28.2%)Rejected-Finance DESHBANDHUPARA PO SILIGURI TOWN DIST DARJEELING PIN 734004 | JALPAIGURI | WEST BENGAL | 734004 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹47.8 L+₹10.6 L (28.5%)Rejected-Finance HAKIMPARA NEAR PAKURTALA MORE SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹47.3 L
EMD Value
₹94,600
Closing Date
14 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bengdubi
Headquarters Commander Works Engineer Bengdubi Post-Bengdubi Distt-Darjleeling (WB)
REPAIR/REPLACEMENT OF STREET LIGHT/GARDEN LIGHTS/SECURITY LIGHTS AND ALLIED WORKS AT SUKNA STN UNDER GE SUKNA
2023_MES_629687_1
8197/S/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Sukna
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Sukna
₹94,600
HQ CWE Bengdubi
10 Feb 2024
24 Nov 2023
21 Dec 2023
24 Nov 2023
14 Dec 2023
8 Dec 2023
4 Dec 2023
Amount
Supplying, laying, jointing and testing XLPE insulated, armoured, heavy duty, electric cable with stranded aluminium conductor 1100 volts grade, cross sectional area 10 Sqmm x 4core in trenches /along poles/on wall etc and including taking down of existing Under Ground cable from trenches/ along wall/pole etc, complete all as specified and as directed Notes for item No 1. : (i) Excavation and earth work, sand cushioning, protection covers shall be measured and paid for separately. (ii) Unless otherwise directed by the GE, the cable shall be procured by the contractor in single length (as manufactured) to meet the actual length of cable as required at site. However, for payment purpose, the length actually ordered & laid shall be measured and paid for.
All as per item No 1.00 here-in-before but LT Cable of size 16 Sqmm x 4 Core.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5m in depth for laying of under ground cables/ pipes and not exceeding 10 Sqm on plan & 1.5 metre in depth for poles/independent holes etc, complete all as specified and directed.
All as per Item No 3 above but depth exceeding 1.5 metre and not exceeding 3.00 metre
Returning, filling in, including spreading, watering and well ramming in layers not exc 25cm thick in layers, complete all as specified and directed.
Removal of surplus spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and directed.
M&L for Sand cushioning in trenches for cushioning of underground cable including spreading, levelling, well ramming in layers not exceeding 25cm in thickness, complete all as specified and directed.
Material and labour for well burnt Sub-class 'B' old size bricks, best quality locally available laid flat, dry in trenches for cable protection, complete all as specified and as directed.
Supply and fixing GI tubing, light grade, 15mm bore for protection of cable , along electric pole or floor /wall etc, incliding taking out existing pipe, complete all as specified and directed.
Supply and fixing GI tubing, light grade, 40mm bore for protection of cable under road crossing, across drain, along electric pole or floor /wall etc, incliding taking out existing pipe, complete all as specified and directed.
Supply and fixing GI tubing, light grade, 80mm bore for protection of cable under road crossing, across drain, along electric pole or floor /wall etc, incliding taking out existing pipe, complete all as specified and directed. Note for Item No.10 to 11 : Excavation & Earthwork and/or boring/drilling for laying/passing of tubing under road etc shall be measured & paid for separately.
Boring (horizontally) manually for passing 40 to 80mm bore pipe for protection of the cable upto 2 metre depth in soil below existing road, pavement, hard standing etc without damaging the existing surfaces, getting out & disposal of soil to a distance not exceeding 50 metre from the site of work, complete all as specified and directed. Note: Cost for provision of pipes & cable not included in the scope of above item.
S&F in repair street light junction box IP 66/69 Weather proof for outdoor installtion, Black colour, having size 155 x 210 x 92 mm with terminals having two knockouts for cable entries from rear side, protected against rain water, temperature resistant and impact resistance with 4 Nos Copper bus bar of 16mm/14mm with necessary insulators complete with holes/nut bolts and colour insulation , including providing mild steel bracket of suitable size, made of 20mmx3mm size flat fixed with 12mm dia mild steel nuts and bolts for fixing on pole, complete all as specified and directed.
S&F in repairs 6 KW, three phase, automatic stree light control panel with and including digital timer switch for automatic switching on / off street light as per set time through programmable 24 hours switch, 32A, TP, power contactor, 40A SPN MCB, wall/ floor mountable, IP 54 (dust and vermin proof) enclosure made out of CRCA sheet duly powder coated, conforming to IS/IEC 6094-4-1, in-built-short circuit protection, locking arrangement with padlock and panel lock complete all as specified and directed.
Supply, providing and testing PVC Insulated, weather proof, FRLS, PVC sheathed cables with multistranded bright annealed copper conductor of size 1.5 Sqmm 3 core for connection of light fittings to pole light junction box, (cable laid through) including taking down old ones, complete all as specified and directed.
S&F in repairs LED street light fitting 70 watt inclusive of lamp made up of pressure die cast aluminium housing environment friendly with high effifiency LED as lighting source and lens enbedded PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. System Lumen Efficasy > 120 Lm/W, 10 kV Surge Voltage protection, Operation Voltage range 140 V-270V and including fixing arragement made out of 40mm bore GI pipe light grade of length not less than 1.2 m, bent to shape, fixed with two pairs of 40 x 5mm MS flat iron clamps, nuts bolts & washers to fix the fitting with pole, complete all as specified and directed. Note for Item No 16 to22: Contractor have to submit LM 79 and LM 80 report form NABL accredited Lab, Test Certificate and other revelant documents as directed by Engineer-in-Charge before approval of product.
S&F in repairs LED street light fitting 90 watt inclusive of lamp made up of pressure die cast aluminium housing environment frendly with high effifiency LED as lighting source and lens enbedded PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. System Lumen Efficasy ≥ 120 Lm/W, 10 kV Surge Voltage protection Operating Voltage range 140 V-270V, and including fixing arragement made out of 40mm bore GI pipe light grade of length not less than 1.2 m, bent to shape, fixed with two pairs of 40 x 5mm MS flat iron clamps, nuts bolts & washers to fix the fitting with pole complete all as specified and directed.
S&F in repair Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium LED Flood Light 120 watt inclusive of lamp , Temered protective toughened glass with IP66, and impact resistant with IK07, System Lumen Efficasy ≥ 120 Lm/W, 10 kV Surge Voltage protection, Operating Voltage range 140 V-270V including fixing arrangement fixed with two pairs of 40 x 5 mm MS flat iron clamps, nuts, bolts & washers to fix the fitting with pole complete all as specified directed.
S&F in repairs new generation, energy saving, environment friendly, having long life and aesthetically designed with symmetrical light distribution LED Post Top lantern inclusive of 15Watt LED lamp with embeded chip LED, conforming to IP 65 having spun aluminium lanscape luminaire with high power LEDs as light source including elecrtronic driver and fixing arrangement etc complete all as specified and directed.
S&F in repairs new generation, energy saving, environment friendly, having long life and aesthetically designed, LED Bollard Light inclusive 10Watt lamp embeded chip LED , conforming to IP 65 for diffused lighting with high power LED as light source, including 1 meter hot dip galvanized pole, driver, all fixing arragnement etc including electrically connecting complete all as pecified and directed.
S&F Solar All-in-One Solar LED street light system with comprising of the following minimum specifications, complete all as directed by the Engineer-in-Charge :- (a) Street Light Wattage:20W (b) Battery: Lithium Ferro Phosphate, 12.8V, 13.6Ah c) Solar Panel: Poly Crystalline, 28W, 17Vmp, 21 Voc V (d) Charge Controller: MPTT,11W(Min) (e) Material: Integrated pressure die cast aluminium (f) CRI: >70 (g)Lumen: Not less than 170lm/watt (h)Color Temp:5700K (j) Optics: UV Stabilized poly carbonate (k) Protection:IP65 IK08 (l) Diming Profile: Yes & cofigurable
S&F Solar All-in-One Solar LED street light system with comprising of the following minimum specifications, complete all as directed by the Engineer-in-Charge :- (a) Street Light Wattage:30W (b) Battery: Lithium Ferro Phosphate, 12.8V, 20Ah c) Solar Panel: Mono Crystalline, 35W, 17Vmp, 21 Voc V (d) Charge Controller: MPTT,17W(Min) (e) Material: Integrated pressure die cast aluminium (f) CRI: >70 (g)Lumen: Not less than 170lm/watt (h)Color Temp:5700K (j) Optics: UV Stabilized poly carbonate (k) Protection:IP65 IK08 (l) Diming Profile: Yes & cofigurable
Material and labour for preparation of old rusted exposed steel surfaces of LT swaged poles of 9m length, cross arms, brackets etc mounted on poles, applying one coat of synthetic enamel paint upto 0.8 metre height as per the existing pattern above the P.C.C coping & one coat of aluminium paint beyond 0.8 metre height (for the remaining exposed surfaces) of the poles as well as on the exposed surfaces of cross arms, brackets etc mounted on the poles, re-writing pole numbers and cutting vegetation growth all around the poles upto 1 metre radius, including replacement of self adhesive fluorescent colour tape as per existing pattern and size, complete all as specified and directed.
S & F in replacement of existing RCC pole with Steel Tubular Poles complete with and including cast iron base plate, finial taper plug, bolts , nuts & screws, type 410 SP-31(09 Metre long), also including painting to the external exposed surfaces with 2 coats of aluminium paint over 1 coat of red oxide primer and with 2 coats of black bituminous paint over 1 coat of red oxide primer to the external exposed surfaces of steel poles embedded in the ground / concrete after preparation of the surfaces, numbering to the poles, complete in all respect as specified and as directed. Note:- Excavation & Earth Work, concrete for foundation and coping shall only be measured and paid for separately.
M & L for cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggrgate) for pole foundation including provision of necessary form work, complete all as specified and directed.
M & L for cement concrete (1:3:6) type C-2 (Using 40mm graded crushed stone aggregates) pole foundation including provision of necessary form work, complete all as specified and directed.
M & L for cement concrete (1:2:4) type B-1 (Using 20mm graded stone aggregates) for coping/Stay of pole etc including provison of necessary form work including demolition, complete all as specified and directed.
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead of GI strip 25x4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, complete all as shown in Electrical Plate No. 3 of SSR Part-1 and connected to earthing test point and including dismantling of old one, complete all as specified and directed. Note: The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C-1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 40 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, aluminium lugs, charcoal and common salt in alternate layer etc.
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel, complete all as shown in Electrical Plate No. 3 of SSR Part-1 and connected to earthing test point and including dismantling of old one, complete all as specified and directed. Note: The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C-1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 15 mm bore GI light grade earth lead rotection pipe, funnel, wire mesh, aluminium lugs, charcoal and common salt in alternate layer etc.
M&L for earth continuity conductor or main earthing lead of size 25X4 mm galvanized iron strip fixed to wall on batten or recess or chases or burried in ground or drawn in existing conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc including dismantling of existing one, complete all as specified and directed.
M&L for earth continuity conductor or main earthing lead of size 4mm dia galvanised iron or steel wire fixed to wall on batten or recess or chases or burried in ground or drawn in existing conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc including dismantling of existing one, complete all as specified and directed.
ENGINEERING AND CONSTRUCTION CO.
M/S G S ASSOCIATES
M/S B B CONSTRUCTION
SHRI N.DAS
M/S GLORIOUS CONSTRUCTION
M/s B. K. Ghosh and Co.
MS ESSCON
DEBABROTA ROY CHOWDHURY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .