| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-Finance 8 13 160 KALYANI NADIA | KALYANI | NADIA | WEST BENGAL | L1 | Accepted-Finance lOWEST | |
| 2 | L2₹12.8 L+₹16,258 (1.29%)Rejected-Finance 14 SURI LANE KOLKATA 14 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L2 | Rejected-Finance SECOND LOWEST | |
| 3 | L3₹13.4 L+₹80,634 (6.40%)Rejected-Finance P O VILL SUGANDHA DIST HOOGHLY WEST BENGAL | SUGANDHA | HOOGHLY | WEST BENGAL | 712102 | L3 | Rejected-Finance TtHIRD LOWEST | |
| 4 | Rejected-Technical 14 MOULABI MUJIBOR RAHAMAN SARANI KOLKATA 17 | KOLKATA | KOLKATA | WEST BENGAL | 700017 | - | Rejected-Technical DOCUMENTS NOT IN ORDER |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
3 Dec 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE PWD CEC
184, C.R.Das Road, Berhampore, Murshidabad
Construction of proposed single storied building with the provision of another two storied future extension for optimum Banking Facility at Haringhata Campus of MAKAUT,West Bengal, under Nadia Construction Division , PWD the year 2020-21 - EI work
2021_WBPWD_348805_1
WBPWD/CEC/eNIQ/07/Q/2021-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
MAKAUT, HARINGHATA
Please refer Tender documents.
4 documents required · 4 mandatory
₹18,000
Yes
VIRTUAL WEB PLATFORM
9 Dec 2025
1 Nov 2021
6 Dec 2021
1 Nov 2021
3 Dec 2021
8 Nov 2021
5 Nov 2021
120 days
Amount
Sub-Head 1--Distribution Wiring
Distn. Wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated and unsheathed single core stranded copper wire (Brand approved by EIC) in 19mm bore, 3mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish. 8 Mtr.
Distn. Wiring in 3 x 22/0.3 (1.5sqmm) single core stranded 'FR' PVC insulated and unsheathed single core stranded copper wire in 19mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240V 6A 5 pin plug point with modular type plug socket and switch as per GS On board
Sub- Head2-- Plugs and Sockets Supply and fixing 240 V, 16A, 3pin Modular type plug socket with 16A Modular type switch, without plug to as per GS.
Supplying and Fixing GI Modular Switch Board of the following sizes complete with three no suitable size copper bar with holes (for Ph, N&E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works 6 module
Supply and fixing 240 V 6A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required
Supply and Fixing 240V, 6A , 5 pin Modular type plug socket (brand approved by EIC) without switch and plug top, on existing GI Modular type switch board with top cover plate and making necy. Connections with PVC Cu wire and earth continuty wire etc
Supply and fixing 240V 25A 3 pin Modular type plug socket (brand approved by EIC) without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. Connections with PVC Cu wire and earth continuty wire etc.
Supply and fixing 240V, 25A Modular type starter (brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch with 4 Module top cover plate flushed in wall incl S&F switch board and cover plate and making necy. connections with PVC cu wire and earth continuty wire etc.
Sub Head3---BDB, PDB VTPN ETC Supplying and fixing double door SPN MCB Distribution Board with IP-42/43 protection concealed in wall as per GS. 2+4 Way (legrand)
2+16 Way (legrand)
Supplying and Fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS (Make- Legrand) 12 Way (up to 160A)
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand ] 63A DP
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS [ Make - Legrand ]. 160A FP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ] 16-32A SP
SUB-HEAD 4-- Polythene pipe and wires Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS. 2x(1.5 sqmm)+1x(1.5 sqmm) (For Computer Plug)
2x(2.5 sqmm)+1x(1.5 sqmm) (For Power plug )
2x(4 sqmm)+1x(2.5 sqmm) (For Split type AC Machine
2x(10 sqmm)+1x(6 sqmm) (For TPNDB to SPNDB)
Cutting Channel of size (31 mm x 31 mm)/(40 mm x 40 mm)/(43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 13/19/25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles as per GS. 19mm dia 3mm thick
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works 150 mm x 100 mm x 65 mm
175 mm x 100 mm x 65 mm
Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required 150 mm x 100 mm x 65 mm
175 mm x 100 mm x 65 mm
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 2.5 sqmm
Supplying and Fixing GI Modular Switch Board of the following sizes Complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl making earthing attachment, painting and mending good damages to building works. a) 2 Module
Supplying and Fixing 240V 16A Modular type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required.
Supplying and Fixing 240V, 4 nos, 16A, 3 pin Moduar type plug socket with 4 nos 16A Modular type switch (Brand approved by EIC)20A Modular switch type SP MCB (C-Curve)as per G.S
S&F 25A timer controller in SS double door phosphatised powder coated 10 way SPN DB, din rail with IP-43 protection with electrical accessories and front door locking arrangement with all connection, a) 25A DP MCB (10 kA, C-curve)----1 no (Legrand) b) 25A SP MCB-----1 No (Legrand) c) 6A SP MCB-----1 No (Legrand) d) Modular contractors-25A-1 no, 1 NC----3 nos(L&T) e) Auxiliary relay-2 no----1 no f) 10 way SPN DOUBLE DOOR DB----1 no -Enclosure (607711) Legrand (For AC machine timer)
S & D of 230 V 450 mm (18'') sweep heavy duty metalic wall bracket fan silent operation and 1350 rpm (make: Orient Wall Tornado)
63A 2 Pole changeover MCB type switch with sheet metal enclosure (Make: L&T)
SUB-HEAD 5-- SUPPLY & LAYING OF CABLES Supply of 4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / Nicco / Fort Gloster] 185 Sqmm
Laying of cable above 35 and upto 185sqmm in underground trench as per GS for the following numbers of Cables
Supplying and fixing compression type gland those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. 4 Core 185 sqmm
Supplying and fixing crimping type finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. 4 Core 185 sqmm
SUB-HEAD 6 -FIXING OF LIGHT FITTINGS Fixing only single/twin fluorescent light fitting in the ceiling fixed with “L” type MS clamp as per GS
Fixing only lamp
SUB-HEAD 7 -Supply OF LIGHT FITTINGS Supply of 4ft LED T-8 box type batten with end cap complete with all accessories (make Philips) i) Philips make cat no- TMC 501 P 1x T-LED 22W P3241
ii) Phillips make cat no-TMC 501 P 2x T-LED 22 W P3242
iii) 22W LED T-8 lamp (type- MAS LED tube STD 1200mm 15W840 T8 I)
iv ) Supply 9W LED lamp to the lamp point. [PHILIPS make]
SUB-HEAD 8 -- FIXING OF FANS Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board as per GS
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS
Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification as per GS
Fixing only exhaust fan after making holes in wall as per GS (9")
Supply & Fixing louver shutter ( Aluminum)on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS (9'')
Engraving the deptt. number with 10 mm lettering on the body of fan upto 10 letters incl. hifen, stroke or stop
Painting upto 10 letters of the engraved number with approved black /red paint as required as per GS
SUB-HEAD 9 -- SUPPLY OF FANS Supply of ceiling fans complete with all accessories having the following Model / Cat No. ( Make -Crompton Greaves ) a) 1200mm Sweep (High Speed)
Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC ) 9" ( 230mm ) Speed 1370 RPM
SUB HEAD-10 C0MPOUND LIGHT Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting. ( 250 x 250 x 100mm )
Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting
Supply & delivery of 30 Watt LED STREET Iight fittings with aesthetically designed roadway with execellent thermal management and IP65 protection [ make- Crompton Greaves , cat no- LSTS-30-CDL).
SUB-HEAD 11-- EARTHING Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
Earthing with copper plate (610 x 610 x 3mm size) having weight of 9.84 Kg and 1 no 25x 5mm copper strip (3.20 mt long) & 1 no 6sqmm PVC insulated stranded Copper wire (4 mt long) incl. S&F 15mm dia GI pipe (ISI-Medium) protection (4mt long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 mts below the ground level and restoring the surface duly rammed incl providing 3.0 mt long 25mm dia GI pipe (ISI Medium) for periodic treatment incl providing masonery enclosure on the top of the earth electrode of overall size 86.36 x 86.36 x 46 Cm deep (below Ground level) Complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 x 35.56 cm with locking arrangement GI reducer and treatment of soil by using salt and charcoal or coke for plate electrode
Supplying & fixing earth busbar including Connecting the equipments of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS (1 Mtr)
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages Solid GI wire No 4 S.W.G wire
Excavation of soil for installation of Earth Electrode and filling & ramming. For soft Soil
Supply and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB. Concealed in wall after cutting the wall and mending good the damages to original finish incl painting connection and provision for earthing attachment. 4 WAY
S&F of digital timer switch 16A with 2 way enclosure (Street light timer)
T.D.K. ENTERPRISE
UNION ENGINEERING COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .