Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.8 LAdmitted-Finance | ₹49.8 L | L1 | Admitted-Finance |
| 2 | L2₹50.4 LAdmitted-Finance | ₹50.4 L | L2 | Admitted-Finance |
| 3 | L3₹50.9 LAdmitted-Finance C O MALAY DUTTA MADHYAPARA OPP DARRANG COLLEGE GIRLS HOSTEL P O TEZPUR DISTT SONITPUR ASSAM 784 001 | SONITPUR | ASSAM | 784001 | ₹50.9 L | L3 | Admitted-Finance |
| 4 | Rejected-Technical MAHABHAIRAB PO TEZPUR DISTT SONITPUR ASSAM PIN 784 001 | SONITPUR | ASSAM | 784001 | - | - | Rejected-Technical NO remarks as per Ser No 475 of WLR of QE Dec 2025 of HQ CEEC |
| Sl No | Description | Qty | Unit | M/S Jiban Krishan Das and Co L3 | BCL L2 | SHANTI ELECTRIC WORKS L1 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down point wiring (light, fan, socket and power complete including fixtures and fittings such as switches ceiling roses, pendents , regulators, sockets etc. removing materials to store for keeping in safe custody for refixing or for taking credit (credit for above items should be made as per conditions separately) and making good distrubed surfaces of walls, floors, etc, complete all as specified and as directed. | 378 | Point | 15 ₹5,670 | 25 ₹9,450 | 20 ₹7,560 |
| 2.00 | M&L Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC casing caping of suitable size with all accessories including PVC box or modular GI/PVC boxes of suitable sizes including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan /call bell point/ Switch socket outlet 5 amps complete all as specified and as directed.
Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. | 200 | Per Point | 600 ₹1.2 L | 700 ₹1.4 L | 700 ₹1.4 L |
| 3.00 | All as per item No. 02 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch, complete all as specified and as directed. | 16 | Per Point | 250 ₹4,000 | 200 ₹3,200 | 190 ₹3,040 |
| 4.00 | All as per item No. 02 here-in-before but one 3 pin 5 amps switch socket commbination on the independent board with other switch complete all as specified and as directed. | 40 | Per Point | 650 ₹26,000 | 700 ₹28,000 | 700 ₹28,000 |
| 5.00 | M&L fo Point wiring surface type with 2.5 sqmm (Nominal Area) PVC insulated stranded single core unsheathed FRLSH copper conductor cable 1100 Volts grade drawn through with and including PVC casing caping with all fittings and accessories of casing caping (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 2.5 Sqmm (nominal area) PVC box or modular GI/PVC boxes of suitable sizes for mounting sockets for 5 pin, 16 Amp Switch socket combination on independent board complete all as specified and directed.
Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. | 20 | Per Point | 850 ₹17,000 | 850 ₹17,000 | 850 ₹17,000 |
| 6.00 | M&L fo Point wiring surface type with 4.0 sqmm (Nominal Area) PVC insulated stranded single core unsheathed FRLSH copper conductor cable 1100 Volts grade drawn through with and including PVC casing caping with all fittings and accessories of casing caping (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 4.0 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FRLSH copper cable as earth continuity wire connecting to common earth point (including s PVC box or modular GI/PVC boxes of suitable sizes for mounting sockets for 5 pin, 16 Amp Switch socket combination on independent board complete all as specified and directed.
Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. | 16 | Per Point | 950 ₹15,200 | 1,000 ₹16,000 | 1,150 ₹18,400 |
| 7.00 | M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium duty with all accessories i PVC box or modular GI/PVC boxes of suitable sizes including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed.
Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
(ii) Chase cutting deemed to be included in quoted rate. | 55 | Per Point | 900 ₹49,500 | 950 ₹52,250 | 950 ₹52,250 |
| 8.00 | All as per item No. 07 here-in-before but one 3 pin 5 amps switch socket commbination on the independent board with other switch complete all as specified and directed by Engineer-in-charge. | 25 | Per Point | 900 ₹22,500 | 950 ₹23,750 | 950 ₹23,750 |
| 9.00 | All as per item No. 07 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge. | 10 | Per Point | 300 ₹3,000 | 250 ₹2,500 | 250 ₹2,500 |
| 10.00 | M&L fo Point wiring surface type with 2.5 sqmm (Nominal Area) PVC insulated stranded single core unsheathed FRLSH copper conductor cable 1100 Volts grade drawn through with and including PVC concealed conduit with all fittings and accessories of conduit pipe (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 2.5 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FRLSH copper cable as earth continuity wire connecting to common earth point (including supply & fixing of 1.6 mm thick pressed mild steel terminal boxes of suitable size with 3 mm thick PVC /plastic laminated sheet, top cover suitable sizes of brass screws and washers etc. or modular GI boxes of suitable size for mounting sockets for 5 pin, 16 Amp Switch socket combination on independent board complete all as specified and directed.
Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board..
(ii) Chase cutting deemed to be included in quoted rate. | 12 | Per Point | 1,200 ₹14,400 | 1,100 ₹13,200 | 1,150 ₹13,800 |
Updated dates
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
14 May 2026, 5:00 pmClosed
GE South Tezpur
GE (S) Tezpur Mission Charali Tezpur-784154
Repairs/maint of UG Cables, internal wiring, fitting and fixation and allied works at certain unit at Misa Camp under GE (S) Tezpur
2026_MES_760597_1
9136
Open Tender
Civil Works
210 days
GE South Tezpur
as per NIT
4 documents required · 4 mandatory
₹500
Yes
GE South Tezpur
₹98,000
Yes
27 May 2026
16 Apr 2026
18 May 2026
16 Apr 2026
14 May 2026
30 Apr 2026
16 Apr 2026 - 23 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
Taking down point wiring (light, fan, socket and power complete including fixtures and fittings such as switches ceiling roses, pendents , regulators, sockets etc. removing materials to store for keeping in safe custody for refixing or for taking credit (credit for above items should be made as per conditions separately) and making good distrubed surfaces of walls, floors, etc, complete all as specified and as directed. | - | Point | - | - | |
M&L Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC casing caping of suitable size with all accessories including PVC box or modular GI/PVC boxes of suitable sizes including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan /call bell point/ Switch socket outlet 5 amps complete all as specified and as directed.
Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. | - | Per Point | - | - | |
All as per item No. 02 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch, complete all as specified and as directed. | - | Per Point | - | - | |
All as per item No. 02 here-in-before but one 3 pin 5 amps switch socket commbination on the independent board with other switch complete all as specified and as directed. | - | Per Point | - | - | |
M&L fo Point wiring surface type with 2.5 sqmm (Nominal Area) PVC insulated stranded single core unsheathed FRLSH copper conductor cable 1100 Volts grade drawn through with and including PVC casing caping with all fittings and accessories of casing caping (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 2.5 Sqmm (nominal area) PVC box or modular GI/PVC boxes of suitable sizes for mounting sockets for 5 pin, 16 Amp Switch socket combination on independent board complete all as specified and directed.
Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. | - | Per Point | - | - | |
M&L fo Point wiring surface type with 4.0 sqmm (Nominal Area) PVC insulated stranded single core unsheathed FRLSH copper conductor cable 1100 Volts grade drawn through with and including PVC casing caping with all fittings and accessories of casing caping (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 4.0 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FRLSH copper cable as earth continuity wire connecting to common earth point (including s PVC box or modular GI/PVC boxes of suitable sizes for mounting sockets for 5 pin, 16 Amp Switch socket combination on independent board complete all as specified and directed.
Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. | - | Per Point | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
9136tenderdocus.pdf
Tender Documents • 1.29 MB
BOQ_851967.xls
BOQ • 0.55 MB
Addldocus.pdf
Additional Documents • 0.16 MB
Download all tender documents and submit your bid