Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 1ST FLOOR S N COMPLEX NEAR NORTH OVER BRIDGE KALOOR ERNAKULAM KERALA 682018 | ERNAKULAM | KERALA | 682018 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance C 712 RAJ HERITAGE L M ROAD BORIVALI MUMBAI MAHARASHTRA 400103 | MUMBAI SUBURBAN | MAHARASHTRA | 400103 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance 213 OSHIWARA INDL CTR NEW LINK RD GOREGAON W MUMBAI MAHARASHTRA 400104 | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance D 595 KAMLA NAGAR AGRA UTTAR PRADESH 282005 | AGRA | UTTAR PRADESH | 282005 | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance L 11 SIDCO INDUSTRIAL ESTATE VILLIVAKKAM CHENNAI TAMIL NADU 600049 | THIRUVALLUR | TAMIL NADU | 600049 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
6 Jul 2022, 2:00 pmClosed
ANITHA S
PURCHASE DEPARTMENT, FACT LTD, P.O. UDYOGAMANDAL PIN - 683501
PORTABLE GAS DETECTORS
2022_FACT_695872_1
MM/150/E25672
Open Tender
Miscellaneous Goods
Supply
UDYOGAMANDAL
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
Exempted
7 Jul 2022
21 Jun 2022
7 Jul 2022
21 Jun 2022
6 Jul 2022
21 Jun 2022
21 Jun 2022 - 6 Jul 2022
Portable Detector for Ammonia Intrinsically safe portable gas detector designed for monitoring the presence of Ammonia vapours. The device shall be ergonomically designed for easy use and fits in the hand for easy sampling and have a data logging facility. Sensor : Ammonia Measuring Range : Min. 0 – 300 ppm Resolution : Min. range Increments 1 ppm Make : Honeywell/ Draegger/ MSA/ Riken-Keiki/ Crowcon/ ION Display : LCD Weight : Not more than 800 grams Operating Temperature: -20o C to 50o C Ingress protection : IP 65 or above Alarms : Visual, Vibration, and Audible (not less than 95 dB) (For TWA, STEL) Pump : Integrated Pump Casing/Boot : High impact, durable, rubberized Language : English Approvals : CE and ATEX/ IECEx : The instrument should have approval from a competent authority to use in Class I, Division 1, group A, B, C, D. Warranty : Minimum 2 Years for the device including the sensor. Minimum one-year warranty for battery/ power supply. Calibration : First calibration after supply shall be done by the supplier without additional cost. • Carrying case shall be provided • Approvals, Calibration Certificates, and Instruction Manual for Operation to be submitted along with the supply.
Portable Detector for benzene Intrinsically safe portable gas detector designed for monitoring the presence of Benzene vapours. The device shall be ergonomically designed for easy use and fits in the hand for easy sampling and have a data logging facility. Sensor : Benzene Measuring Range : Min. 0.00 – 200.00 ppm Resolution : Min. range Increments 0.1 ppm Make : Honeywell/ Draegger/ MSA/ Riken-Keiki/ Crowcon/ ION Display : LCD Weight : Not more than 800 grams Operating Temperature : -20o C to 50o C Ingress protection : IP 65 or above Alarms : Visual, Vibration, and Audible (not less than 95 dB) (For TWA, STEL) Pump : Integrated Pump Casing/Boot : High impact, durable, rubberized Language : English Approvals : CE and ATEX/ IECEx/PESO : The instrument should have approval from a competent authority to use in Class I, Division 1, group A, B, C, D(or Zone1, group IIA, IIC). Warranty : Minimum 2 Years for the device including the sensor. Minimum one-year warranty for battery/ power supply. Calibration : First calibration after supply shall be done by the supplier without additional cost.. •Carrying case shall be provided •If the equipment uses pre-filter tube or any other consumables, vendor shall provide sufficient number of such consumables along with the detector, so as to take min. 20 measurements. • Approvals, Calibration Certificates, and Instruction Manual for Operation to be submitted along with the supply.
Portable Detector for Chlorine Intrinsically safe portable gas detector designed for monitoring the presence of Chlorine vapours. The device shall be ergonomically designed for easy use and fits in the hand for easy sampling and have a data logging facility. Sensor : Chlorine Measuring Range : Min. 0.0 – 10.0 ppm Resolution : Min. range Increments 0.1 ppm Make : Honeywell/ Draegger/ MSA/ Riken-Keiki/ Crowcon/ ION Display : LCD Weight : Not more than 800 grams Operating Temperature : -20o C to 50o C Ingress protection : IP 65 or above Alarms : Visual, Vibration, and Audible (not less than 95 dB) (For TWA, STEL) Pump : Integrated Pump Casing/Boot : High impact, durable, rubberized Language : English Approvals : CE and ATEX/ IECEx : The instrument should have approval from a competent authority to use in Class I, Division 1, group A, B, C, D. Warranty : Minimum 2 Years for the device including the sensor. Minimum one-year warranty for battery/ power supply. Calibration : First calibration after supply shall be done by the supplier without additional cost.. • Carrying case shall be provided • Approvals, Calibration Certificates, and Instruction Manual for Operation to be submitted along with the supply.
Portable Detector for SO2 Intrinsically safe portable gas detector designed for monitoring the presence of SO2 vapours. The device shall be ergonomically designed for easy use and fits in the hand for easy sampling and have a data logging facility. Sensor : Sulphur dioxide Measuring Range : Min. 0.0 – 100.0 ppm Resolution : Min. range Increments 0.1 ppm Make : Honeywell/ Draegger/ MSA/ Riken-Keiki/ Crowcon/ ION Display : LCD Weight : Not more than 800 grams Operating Temperature : -20o C to 50o C Ingress protection : IP 65 or above Alarms : Visual, Vibration, and Audible (not less than 95 dB) (For TWA, STEL) Pump : Integrated Pump Casing/Boot : High impact, durable, rubberized Language : English Approvals : CE and ATEX/ IECEx : The instrument should have approval from a competent authority to use in Class I, Division 1, group A, B, C, D. Warranty : Minimum 2 Years for the device including the sensor. Minimum one-year warranty for battery/ power supply. Calibration : First calibration after supply shall be done by the supplier without additional cost. • Carrying case shall be provided • Approvals, Calibration Certificates, and Instruction Manual for Operation to be submitted along with the supply.
LEL DETECTOR WITH EXTERNAL PUMP Intrinsically Safe portable combustible gases and vapours detector (LEL detector) designed for sampling /monitoring confined spaces and as personal gas detector. Detector shall be capable to work on diffusion mode and with external attachable pump. The device shall be ergonomically designed for easy use and have Data logging facility. External Pump should have separate battery and charging facility. It Shall be capable to connect quickly to the detector. The instrument shall be made of non-corrosive material and should have alligator clip. Sensor (s) : LEL (Combustible Gas), Range: 0-100% LEL, Resolution: 1% LEL (Other than Hydrocarbons, Sensor should also detect combustible gases including, Ammonia, Hydrogen and Acetylene) Pump Capacity : Capable to take sample from 30 M depth Display : LED with backlight Weight : Individual detector – not more than 250 grams, Detector and pump combined – Not more than 500 grams Operating Temperature : -20℃ to 50℃ Ingress protection : Minimum IP67 Battery : Rechargeable with operation time not less than 12 hours in one full charge (detector and pump combined) Alarms : Visual, Vibration and Audible Language : English Warranty : Minimum 3 Year for detector including sensor (s) and minimum 1 year for pump, charger (s) and batteries. Approvals : ATEX - II 1G Ex da ia IIC T5/T4/T3 Ga, CE Certified, Tested as per EN 60079-29-1, IECEx Sampling hose / line of minimum 5 meter, sampling probe and connectors shall be supplied along with equipment. The unit should be provided with protective boot and to be packed with all accessories in an easy to carry case. The instrument should have approval from competent authority to use in Class I, Division 1, group A, B, C, D. The instrument should be supplied with Battery, Charger (cradle/power plug should be compatible with Indian standards), calibration certificate and relevant test certificates. First Calibration after supply shall be done in free of cost by the supplier.
TRITECH
RESPO PRODUCTS
Detection Technology Pvt. Ltd.
SARVAM SAFETY EQUIPMENT PVT LTD
Cochin Fire Tech
Prism Gas Detection Pvt. Ltd.
Bidder Name
Detection Technology Pvt. Ltd.
stage.html
html • 0.03 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .