| 1.00SCHEDULE A PART-I (BUILDING WORKS) | ||||||
| 1.01 | Construction of 01 No (G+I) LGSF Building for 42 Mahila Soldiers including all internal & external finishes, all connected fittings & fixtures, making provisioning for other schedule items from schedule No. 2 to 4, Vitrified Tiles flooring, Granite stone slab in steps & Cooking platform, Ceramic Tiles in wall Toilet & kitchen, Non Skid Tiles in Toilet & bath room floor , Plinth protection with drains and Anti Termite Treatment. All as per standard specification and drawing Number . DGAR/Engr/LGSF/ 352 Sheet No. 1/21 to 21/21 (Excluding internal electrifications, internal water supply & sanitary fittings which are listed in subsequent schedules) | 697.65 | Sqm | 3,62,77,800 ₹3,62,77,800 | 3,52,30,627.35 ₹3,52,30,627.35 | 2,97,54,772.5 ₹2,97,54,772.5 Lowest |
| 2.00SCHEDULE A APRT-I (b) (Sanitary Installations) | ||||||
| 2.01 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group B | 196 | Points | 1,79,340 ₹1,79,340 | 1,76,400 ₹1,76,400 Lowest | 4,31,200 ₹4,31,200 |
| 2.02 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated
copper conductor single core cable etc. as required. | 46 | Points | 41,860 ₹41,860 | 41,400 ₹41,400 Lowest | 1,01,200 ₹1,01,200 |
| 2.03 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single
core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS
PVC insulated copper conductor single core cable for loop
earthing as required | 3 | Mtrs | 1,215 ₹1,215 | 1,200 ₹1,200 | 900 ₹900 Lowest |
| 2.04Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. | ||||||
| 2.05 | (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 300 | Mtrs | 93,000 ₹93,000 | 90,000 ₹90,000 Lowest | 1,50,000 ₹1,50,000 |
| 2.06 | (b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 1,010 | Mtrs | 3,93,900 ₹3,93,900 Lowest | 4,04,000 ₹4,04,000 | 5,20,150 ₹5,20,150 |
| 2.07 | (c) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 695 | Mtrs | 3,64,875 ₹3,64,875 Lowest | 3,82,250 ₹3,82,250 | 3,96,150 ₹3,96,150 |
Tender Value
₹4.0 Cr
EMD Value
₹7.9 L
Closing Date
30 Jan 2025, 9:00 amClosed
SO-1 (Works), HQ DGAR
HQ DGAR, Engineer Branch
Provn of 01 Nos G1 (LGSF) for mahila soldiers of Bn HQ 18 AR at Agartala (Tripura)
2025_ARMHA_843938_1
VIII.11014/8796/21 Sect/Women Bk/2024
Open Tender
Civil Works
Works
365 days
Agartala
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
Directorate General Assam Rifles S
₹7.9 L
Yes
5 Mar 2025
10 Jan 2025
31 Jan 2025
10 Jan 2025
30 Jan 2025
10 Jan 2025
10 Jan 2025 - 24 Jan 2025
SCHEDULE A PART-I (BUILDING WORKS)
Construction of 01 No (G+I) LGSF Building for 42 Mahila Soldiers including all internal & external finishes, all connected fittings & fixtures, making provisioning for other schedule items from schedule No. 2 to 4, Vitrified Tiles flooring, Granite stone slab in steps & Cooking platform, Ceramic Tiles in wall Toilet & kitchen, Non Skid Tiles in Toilet & bath room floor , Plinth protection with drains and Anti Termite Treatment. All as per standard specification and drawing Number . DGAR/Engr/LGSF/ 352 Sheet No. 1/21 to 21/21 (Excluding internal electrifications, internal water supply & sanitary fittings which are listed in subsequent schedules)
SCHEDULE A APRT-I (b) (Sanitary Installations)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
(a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
(b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
(c) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
(d) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
(e) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.(20) 2 Pair
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.(40)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20mm (T.V+Telephone+Network)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
(a) 5/6 A switch
(b) 2 way 5/6 A switch
(c) 15/16 A switch
(d) 3 pin 5/6 A socket outlet
(e) 6 pin 15/16 A socket outlet
(f) Telephone socket outlet
(g) TV antenna socket outlet
(h) Bell push
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
(a) 1 or 2 Module (75 mmX75 mm)
(b) 3 Module (100 mmX75 mm)
(c) 4 Module (125 mmX75 mm)
(d) 6 Module (200 mmX75 mm)
(e) 8 Module (125 mmX125 mm)
(f) 12 Module (200 mmX150 mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required
(a) 1 or 2 Module
(b) 3 Module
(c) 4 Module
(d) 6 Module
(e) 8 Module
(f) 12 Module
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and flxing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and flxing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and flxing brass batten/angle holder including connection etc. as required.
Installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/ LED lamps per fitting, complete with all accessories including connections etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as requir
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage,connection, testing, commissioning etc. as required. Upto 450 mm sweep, Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required
(a) 1 run of cable
(b) 2 run of cable
(c) 3 run of cable
MCB, MCCB and DISTRIBUTION BOARDS Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator
(a) 4 way (4 + 12), Double door
(b) 6 way (4 + 18), Double door
(c) 8 way (4 + 24), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
(a) Single pole
(b) Single pole and neutral
(c) Double pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
(a) 40 amps
(b) 63 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
(a) 40 amps
(b) 63 amps
(c) 100 amps
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as require
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
CEILLING FAN Supply of AC 230/250 volts, 50 HZ energy efficient ceiling fan with standard down rod, blades, 2 nos. caps etc. complete 1200 mm swee
Supply of AC 230/250 volts, 50 HZ exhaust fans including providing nuts, bolts, mounting frame and other accessories etc. complete 300 mm sweep 900 rpm
Supply of type fluorescent tube light fitting suitable for 1*18w fluorescent tube complete including tubes etc. on surface complete in all respects
Supply of Square LED surface ceiling Light Flat panel which provides soft- light and glare free symmetrical illumination LEDs 36 W LED as approved by Engineer in charge complete in all respect.
Supply of LT XLPE PVC aluminium Unarmoured cable 50 Sq.mm 4core 1100 volt.
Supply of LT XLPE PVC aluminium Unarmoured cable 150 Sq.mm 4core 1100 volt.
Supply of Gyser instant type @ 25 lpm capacity, 30⁰ output
SCHEDULE-A PART-III ( Internal water supply , Sanitary Fittings and Plumbing)
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern.
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board, 610x460 mm bowl depth 200 mm.
PIPE FITTINGS
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 MM
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5°- 110 mm bend
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing terminal guard : Sand cast iron S&S as per IS - 3989
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet : Sand cast iron S&S as per IS: 3989
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge
(a) Internal work - Exposed on wall. 20 mm nominal outer dia Pipes
(b) Internal work - Exposed on wall. 25 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 25 mm nominal outer dia Pipes.
Providing and fixing Ball Valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore.
C P BRASS FITTINGS
Providing and fixing uplasticised PVC connection pipe with brass unions : 15mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (1000 ltrs capacity x 5 Nos)
C P FITTINGS
Providing and fixing C.P. brass Bib Cock of approved quality conforming to IS:8931 :(15 mm nominal bore
Providing and fixing C.P. Brass Long Body Bib Cock of approved quality conforming to IS standards and weighing not less than 690 gms. (15 mm nominal bore)
Providing and fixing PTMT pillar cock of approved quality and colour
Providing and fixing C.P. Brass Stop Cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
Providing & Fixing C.P. brass angle valve
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms
Providing and fixing C.P. Brass Shower Rose with 15 or 20 mm inlet : 100 mm diameter
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long Towel Rail with total length of 645mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
Providing & Fixing C.P Paper Holder parryware Make
SCHEDULE-A PART-IV ( Lightning Conductors)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
M& L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwedincluding 3Nos 8mm dia 25mm long hex, head screw.
M&L for Aluminium Strip 25x3.15mm with saddles and fixing screws etc, for roof conductors and down conductors above ground.
Providing and fixing 25 mm X 5 mm Aluminium strip on surface or in recess for connections etc. as required.
SCHEDULE-B (Development Wks)
SCHEDULE-A PART-V ( EARTH CUTTING & FILLINGS)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. For Length = 15 RM
SCHEDULE-A PART-VI ( INTERNAL ROAD WORK)
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Supplying and stacking at site. 90 mm to 45 mm size stone aggregate
Supplying and stacking at site 63 mm to 45 mm size stone aggregate
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density. 63-45 mm size Stone Aggregate
Ditto but 90-45 mm size Stone Aggregate
Supplying and stacking at site. Stone screening 13.2 mm nominal size (Type A).
Supplying and stacking at site.Stone screening 11.2 mm nominal size (Type B).
Supplying and stacking at site. Red bajri
Supplying and stacking at site. Moorum.
2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings of 13.2mm and 11.2mm size respectively per 100 sqm. and 52 kg. and 56 kg. of hot bitumen per cum of stone chippings of 13.2 mm and 11.2mm size respectively including a tack coat with hot straight run bitumen including consolidation with road roller of 6 to 9 tonne capacity etc. complete.(tack coat to be paid for separately) With paving Asphalt grade VG - 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt
Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and applying tack coat using hot straight run bitumen of grade VG - 10 including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications. On W.B.M. @ 0.75 Kg / sqm.
Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface including rolling and finishing with road roller all complete.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 5 km, also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc., complete.
SCHEDULE-A PART-VII ( PATH WAY)
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth. 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). level
Centering and shuttering for Mass Concrete
Providing and laying 80mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-incharge).
SCHEDULE-A PART-VIII ( EXTERNAL WATER SUPPLY
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work
(a) 32 mm dia nominal bore
(b) 40 mm dia nominal bore
(c) 50 mm dia nominal bore
(d) 62.50 mm dia nominal bore
(e) 75 mm dia nominal bore
Providing and fixing gun metal non- return valve of approved brand 80 mm nominal bore Horizontal
Construction of Masonary Chamber 60x60x75 inside in Brickwork Cement Mortar 1.6 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 80 mm dia
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)
(a) 32 mm dia nominal bore
(b) 40 mm dia nominal bore
(c) 50 mm dia nominal bore
(d) 65 mm dia nominal bore
(e) 80mm dia nominal bore
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering (for thrust blocks at bends and junctions of water lines ) by 1:2:4 (1 cement : 2 coarse sand : 4 graded stone agg. 20 mm nominal size)
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality LD- 2.5 Rectangular shape 600*450 mm internal dimensions
SCHEDULE-A PART-IX ( EXTERNAL SEWAGE DISPOSAL
Construction of 01 No Septic Tank 100 Users as per specifications and drawing No. DGAR/Engr/ 355 Sheet No.1/1
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W.drain pipe 100 mm diameter, 1.8 m long complete as perstandard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. Drawing No. DGAR/Engr/ 356 Sheet No. 1/1
Constructing brick masonry manhole in cement mortar 1 : 4 (1 cement : 4 coarse sand) with RCC top slab with 1 : 2 : 4 mix (1 cement :2 coarse sand : 4 grade stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat of neat cement complete as per standard design . Inside size 90 x 80 cm & 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensions, total weight of cover & frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay F.P.S.(non modular) bricks of classic designation 7.5
Extra for depth for manholes: size 90 X 80 cm With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5
Ditto but Inside size 120 x 90 cm & 90 cm deep including CI cover with frame (Medium duty) 560mm internal diameter, total wt. of cover & frame to be not less than 208 kg (wt. of cover 108 kg and wt. of frame 100 kg) 19.7.3.1 With common burnt clay F.P.S.(non modular) bricks of classic designation 7.
Extra for depth for manholes: size 120x90 cm With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5
Excavating trenches of required width for pipes, cable, etc including excavation for sockets and dressing of sides, ramming of bottoms,depth upto 1.50m including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering,etc & disposing of surplus excavated soil as directed within a lead of 50m. All kinds of soil. Pipes cables etc. exceeding 80 mm dia. But not exceeding 300mm dia.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc.complete : 150 mm dia. R.C.C. pipe
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for mass concrete.
Providing and fixing square mouth S. W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 180 x 150 mm. size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20 mm diameter round bar
SCHEDULE-A PART-X ( STORM WATER DRAINS)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soi
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (40% of Item No. 1)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Ditto but - 1:5:10 (1 Cement : 5 coarse sand : 10 graded stoneaggregate 40 mm nominal size)
Brick work with F.P.S. bricks of class designation 75in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
12 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
SCHEDULE-A PART-XI ( EXTERNAL ELECTRIFICATIONS)
FLOOR PANEL ( LOCATED AT GROUND FLOOR ) Incoming 1 No. 125A FP on load change over switch with 1 no. 125A TPN MCCB(25KA) with extendeble rotary handle each with thermal over current, instantaneous, short circuit release, earth fault. Metering for incoming: Digital Multifunction meter with RS-485 communication port for measurement of PF, V, A & Hz , equivalent to EM6459,with CT as required. Phase indicating lamps RYB with 2 Amps SP MCB back up. ON / OFF indicating lamps Bus Bars: Electrolytic high conductivity Aluminium three phase and neutral busbars rated at 80 Amps, insulated with heat shrinkable coloured PVC sleeves & clip on shroudsfor joints. Current density of Bus Bar to be 1.3 sq.mm / amp. Outgoings 3Nos. 63 amp TPN MCB of 10 KA breaking capacity 2 No. 40 amp TPN MCB of 10 KA breaking capacity SPARE- 2 No. 40 amp TPN MCB of 10 KA breaking capacity FLOOR PANEL as described above .
Supply installation, testing and commissioning of external post top lantern with following and complete as required.
(a) 6m high (5.0m above ground) SP 4 STEEL pole as approved, adopting socket at top for fixture mentioned below, base plate 300x300x6mm and provision for mounting junction box etc.- 1 set
(b) Erection of Pole in cement concrete 400x400x1000mm deep 1:3:6 ratio cement concrete foundation including excavation , refilling, secured with holding clamps, bolts, nuts, alighnment of poles casting etc. including 100 mm thick lean concrete shall be provided at the bottom.
(c) LED type 50 Watt (Street Light) light fittings of all types with all accessories.
(d) Suitable size Control box with 1 no. incoming and 2 nos. outgoing terminals and 2 nos. tap-out terminal with 1 no.5A HRC fuses complet 1 set
(e) Suitable number (S) 40mm dia Class-B GI Pipes(s) from above control box to upto 0.5 meter below ground level for power cable entry.
LT CABLES
Supply of following size of 1.1 KV grade multicore aluminium cunductor PVC sheathed armoured cable as per IS 1554.
(a) 3.5 Core 300 Sqmm
(b) 4 Core 25 Sqmm
(C) 4 Core 16 Sqmm
(d) 3.5 Core 240 Sqmm
(e) 3.5 Core 95 Sqmm
(f) 2 Core 120 Sqmm
(g) 2 Core 50 Sqmm
(h) 2 Core 16 Sqmm
(j) 2 Core 10 Sqmm
GI EARTH PIPE ELECTRODE WITH SALT/ CHARCOAL
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required
Providing and fixing 25 mm x 5 mm copper strips in 40 mm dia G.I.pipe from earth electrode, including connection with brass nut bolts , spring washer, excavation and refilling etc, as required ( copper plate earthing)
Providing and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I.pipe from earth electrode, including connection with brass nut bolts , spring washer, excavation and refilling etc, as required ( copper GI plate earthing)
Providing & laying earth connection from earth electrode with 6 SWG dia copper WIRE from earth electrode including connection with GI thimble excavation and efilling etc as required. ( for GI pipe earthing of poles)
Supply & Laying of 25 x 5 mm copper earth strip in surface /recess
Providing and fixing 25mm x 5 mm copper strips on surface or in recess for connections etc. as required
Providing and fixing MV danger notice plate of 200 mm x 150 mm made of mild steel atleast 2 mm thick and vitreous enameled white on both sides & with inscription in signal red colour on front side as required.( on 7mts poles & panels)
LT CABLES LAYING
SMup) plying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conformg to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required
(a) 63 mm dia (OD-63 mm & ID-51 mm nominal)
(b) 90 mm dia (OD-90 mm & ID-76 mm nominal)
(c) 120 mm dia (OD-120 mm & ID-103 mm nominal)
(d) 160 mm dia (OD-160 mm & ID-135 mm nominal)
Supplying and making end termination with brass comperession gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required
(a) 4 Core 25 Sqmm
(b) 4 Core 16 Sqmm
(c) 3.5 Core 240 Sqmm
(d) 3.5 Core 95 Sqmm
(e) 2 Core 50 Sqmm
(f) 2 Core 16 Sqmm
(g) 2 Core 10 Sqmm
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil. Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe
EXSERVICEMAN ENTERPRISES (BID ID -3163951)
phoeninxinfra (BID ID -3163927)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 26.92 MB
BOQ_887079.xls
BOQ • 0.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .