| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.4 CrAccepted-AOC BUILDING NO FLAT NO B4 32 CHITRAKOOT NAGAR VAISHALI NAGAR NEAR PHONIX DENTAL CARE JAIPUR 302021 | JAIPUR | RAJASTHAN | 302021 | ₹47.4 Cr Quoted ₹47.6 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹64.7 CrRejected-AOC 1 13 16 G KHAPARADEEH KOTHI CAMPUS CIVIL LINES AYODHYA UTTAR PRADESH 224001 | AYODHYA | AYODHYA | UTTAR PRADESH | 224001 | ₹64.7 Cr | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical DOES NOT QUALIFIES PQR |
| 4 | Rejected-Technical | - | - | Rejected-Technical DOES NOT QUALIFY PQR |
| 5 | Rejected-Technical 1630 SECTOR 7C CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | - | - | Rejected-Technical DO NOT QUALIFIES |
Tender Value
₹28.4 Cr
EMD Value
₹56.7 L
Closing Date
12 Aug 2024, 5:00 pmClosed
SE C AND P I
v c v gabar singh urja bhawan
Electrification works of ITBP Border out post BoPs Vibrant Villages under Revamped Distribution Sector Scheme in MANA VALLEY
2024_UPCLC_71072_2
CCP-I/ 62/ 2023-2024
Open Tender
Electrical Works
990 days
v c v gabar singh urja bhawan
As per tender
6 documents required · 6 mandatory
₹29,500
EE HEADQUARTER
₹56.7 L
v c v gabar singh urja bhawan
22 Apr 2026
24 Apr 2024
13 Aug 2024
24 Apr 2024
12 Aug 2024
20 Jun 2024
14 May 2024
Amount
New Substation 2x5 MVA
33 KV MATERIAL
Electricals Equipments
33 KV Lightening Arrester 10KA
MS Plate 300x300x8 mm.
HT Cable warning tape
33kV 3 Pole 1250A Line Isolator (Verticle Type)complete set.
33 KV Bus isolator
33 KV Fuse set
33 KV Aluminium 3x300 sq. mm. XLPE cable
Heat Shrinkable jointing kit for 33 kV 3cx300 Sq. mm. XLPE outdoor (including Extra Long Copper braid for Cable Earthing As Per Site Requriment)
33kV Indoor cable termination kit (3CX300 SQMM)
11kV 3CX240 SQMM XLPE Cable and its laying in Trenches(double ckt)
11kV 3CX120 SQMM XLPE Cable and its laying in Trenches
33 kV 3CX70 SQMM XLPE Cable and its laying (double ckt)
Heat Shrinkable jointing kit for 11 kV 3cx120 Sq. mm. XLPE outdoor (including Extra Long Copper braid for Cable Earthing As Per Site Requriment)
11kV Indoor Cable termination kit (3CX120 SQMM)
11kV Outdoor Cable termination kit (3CX240 SQMM)
11kVindoor Cable termination kit (3CX240 SQMM)
33kV Outdoor Cable termination kit (3CX70SQMM)
33 kV Indoor Cable termination kit (3CX70SQMM)
5 MVA, 33/11 KV Power Transformer with On Load Tap Changer with complete RTCC & related accessories
63 kVA, 33/0.4 KV Oil Cooled Type for Substation supply.
GI pipe 4" dia. 3mtr long ( for double pole & bus bar gantry)
Clamp of MS Flat 50x6 mm. of suitable size for holding 6" & 4" dia. Pipe All galvenized
11 kv 9kV, 10kA Outdoor type Lighting Arrestors
11kV 800A Outdoor Type Isolators (TPMO Switch)
33kV Gas Insulated Switchgear (GIS) with Vacuum Circuit Breaker Panel Board Indoor type (With termination kits) CT, PT, Microprocessor based Protection Relay, Metering equipments, Extinsible both sitdes, Bus Bars etc, consist of:
Incomer/Outgoing Panel with CT Ratio 600-300/5-5A
Outgoing Panel with CT Ratio 600-300/5-5A
11kV Gas Insulated Switchgear (GIS) with Vacuum Circuit Breaker Panel Board Indoor type (with termination kits) with required CT, PT, Microprocessor based Protection Relay, Metering equipments, Extinsible both sitdes, Bus Bars etc, consist of:
Incomer Panel with CT Ratio 600-300/5-5A
Outgoing Panel with CT Ratio 400-200/5-5A
11 KV Bus Coupler Panel
Bus Riser Panel
LT Power & Control Cable from Station T/F to AC DB along with suitable crimping lugs and its laying:
LT Cable Al. 3.5Cx70 Sq.mm.PVC for Stn. T/F to ACDB.
LT PVC cable 4x10 sq. mm.
(iii) LT PVC Cable Aluminium 2X6 Sq MM(armoured)
i. 10C x 2.5 Sq. mm.
ii. 4C x 2.5 Sq. mm.
iii 2C x 2.5 Sq. mm.
(v) Sundries items Cable tie, Alu lug, Copper lug & HT, LT tape, pvc compound, ferrule, pvc flexible pipe, paint writing on panels, HT LT diff size cable gland.with coppper lugs & other miscellaneous material at substation
Battery & Charger
110V Battery Set (300AH) - Tubular type
110V Battery Charger (300AH) with Automatice boost and trickle charge.
110V DCDB
AC Power distribution Board
Earthing of Substation and equipments
(i) 32MM MS Round
(ii) 65X6MM GI Strip
(iii) 40X6 GI Strip
M.S. Bolt & Nut Off size all galvenized
Special earthing by treatment of soil with highly conducted material like combination of bentonite, conductive cement, coke dust, sodium carbonate, MgSo4, NaCl & CaCl2 as per ISS 3043-1987 as per annexure -A (including cost of all material & labor)
BUS BAR & CONNECTORS AT 33/11 KV SUB-STATION
ACSR Panther conductor
ACSR Weasel conductor
33 KV Polymer pin insulator with pin & nut
Connectors suitable for Panther
1. For LA suitable for panther
2. For T/F suitable for panther & HT side
3. For T/F suitable for LT side
2. For Isolators(For Panther)
Connectors suitable for Dog
1. For LA for Dog
2. For Isolators(For Dog)
3. For station transformer suitable for weasel
PG clamp/Wedge type for ACSR Dog
E-Clamps with nut & bolt all galvenized
Flexible copper connection on neutral bushing of power & station transformer 500X50 mm heavy duty with copper lug at ends.
Making cable trench.including fabrication, fixing of MS angle 50x50x6 mm size (excluding the cost of MS Angle/ MS bar) on side edge with all excavation of size (lxbxh) 70x1x1.5, CC work, brick work, fixing of cable support angle one/two tier as required with stopper arrangement at 0.5 mtr gap throughout the length of the trench, making of cable trench covers with MS Bar welded mesh angle frame of MS angle 40x40x6 mm. with lifting hooks, fixing of perforated tray complete as per drawing including cost of sand, cement, bricks, metal (gitti) etc.
Cost of fire & safety equipments of Substation
(i) CO2 type ire Extingusher confirming IS 2878-1976 and cylinder fully charged of 4.5kg capacity
(ii) Foam type Fire Extingusher portable type 5 Lit capacity hang on wall with bracket complete as required.
(iii) Metal fire bucket with sand
(iv) Stand of chuggi type of MS Angle 50X50X6 MM with top covered by MS sheet 1.5MM thickness duly painted with Red color including fabrication complete
Mics items for Substation like:
Rubber mat Class C 3 mm Synthetic Insulating Mat- Confirming to IS 15652 : 2006. Along the all equipments in Control Room.
Danger board
Shut down / Break down board (Bi-lingual Hindi & English)
HT Hand Gloves
Galvenised Perforated Cable Tray
(iii) 100MM
DP structure S.T. Pole 11 mtr. Long SP-55(Bottom Portion hot dip Galvanized) for ststion t/f with all fittings, channels etc. complete work
P.P. & galvenized Clamps for S.T. Pole SP-55 with nut & bolts
Clamp of required size for holding cable supporting angle, pipe, cable & bus isolator handle on double pole & bus bar gantry
Stone Pad 300x300x75
GI pipe 4" dia. 3mtr long ( for double pole & bus bar gantry)
Insulators for holding earthing strip of lightening arrestor & transformer neutral
G.I.pipe 40/50 mm out.dia. & thickness 4/5 mm, 6 mtr. Long for making opearting mechanism for vertical bus isolator
MS Earthing rod 20x2500mm galvenized
GI Wire 6 SWG
Incoming/Outgoing 33KV/11kV Double Pole Strcuture complete in all respect including MS Channel, Earth Rod, Stay Set, Polymer Isnulators, Dics Fittings, GI wire,PP& clamps, fuse set,TPMO SWITCH, GI Pipe 4"X3.0Mt, MS Plate,complete structure for S/S T/F as per electricity noms complete
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 KV Polymer Disc Insulator B&S type
11 KV disc fitting for weasal Conductor
11 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type, Gang Operated, AB Switch
11 kV Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD
GI Stay Wire 7/10 SWG
11 kv 9kV, 10kA Outdoor type Lighting Arrestors
11 KV fuse set.
P.P. & galvenized Clamps for S.T. Pole
Galvenized Bracing Clamp for ST Pole
Galvenized Stay clamp for ST Pole
Galvenized Clamp of required size for holding cable supporting angle, cable & TPMO handle
Name plate of feeder with galvenized clamp
11 KV Danger board with galvenized clamp
GI pipe 4" dia. 3mtr long ( for double pole & bus bar gantry)
MS strcuture steel, angle, channel, Rail, MS Bar, RS Joist, MS Plate. All galvenized
Fabrication & supply of Wire mesh frame made of 8 SWG wires frame of 40x40x5 mm angle M.S. (3 mrx1.8 mr), MS flat & suitable 8mm plate & supply of 2 mtr long, 1.8 mtr high Wire mesh gate of 2 Nos panels with the help of 40 mm dia pipe & 35x5 mm MS flat, with proper provision of locking arrangements in two piece and 1.0x1.8 mtr gate Including all material & labour charges.
Testing of S/s
Construction of 33KV Bay
33 KV Material
Control Panel Inc 33 KV single Feeder 24 V,
33 KV, 1250A, 3 Phase O/D type , VCB 24 V DC.
33kV 3 Pole 1250A Line Isolator (Verticle Type)complete set.
33 KV Bus isolator
33 KVCT Out door with junction box, 33 KV CTR 400-200/1-1-1 A
Junction box for CT
33 KV Lightening Arrester 10KA
Heat Shrinkable jointing kit for 33 kV 3cx300 Sq. mm. XLPE outdoor (including Extra Long Copper braid for Cable Earthing As Per Site Requriment)
33 KV Post Insulator
HT Cable warning tape
G.I pipe 6"dia
Laying of 33 KV Cable by excavation, depth 1 mtr of cable trench in mixed soil and c:c road, levelling/dressing at base, properly laying of the cable by placing bricks on both side & top of the cable filling of 250 mm layer sand from the top so as to cover the cable completely and then filing excavated soil upto 300 mm then spreading of cable warning tape & covering of the trench completely with excavated mixed soil, compacting the soil upto ground level including cost of sand, first class bricks, etc.
33 KV Aluminium 3x300 sq. mm. XLPE cable
LT control cable
LT Control Cable
i. 10C x 2.5 Sq. mm.
ii. 4C x 2.5 Sq. mm.
iii 2C x 2.5 Sq. mm.
Perforated tray 400/ mm width for cable trench galvenized
Perforated tray 300 mm width for cable trench galvenized
Perforated tray 100 mm width for cable trench galvenized
Making cable trench.including fabrication, fixing of MS angle 50x50x6 mm size (excluding the cost of MS Angle/ MS bar) on side edge with all excavation of size (lxbxh) 70x1x1.5, CC work, brick work, fixing of cable support angle one/two tier as required with stopper arrangement at 0.5 mtr gap throughout the length of the trench, making of cable trench covers with MS Bar welded mesh angle frame of MS angle 40x40x6 mm. with lifting hooks, fixing of perforated tray complete as per drawing including cost of sand, cement, bricks, metal (gitti) etc.
Earthing work
Straightening and laying of Earth mat of 32 mm M S round 0.6 mtr deep in mixed soil according to drawing or as per UPCL direction or/and as per site requirement. Making T-joints, cross joint and Lap joints by welding of M S round bar together using cleats of MS Angles 65x65x6 mm, chipping the slag and painting of the joints with black bitumen paint (including supply of paint) to avoid rusting. Cutting & making electrode 2.5 mtr long with conical pointed bottom and driving of the electrode remains 450 mm below ground level. Backfilling of soil in trenches, ramming and leveling of trench properly after completion of eartmat and earthing work is complete. Making of Delta/Bridge earthing for structure/panels i.e. LA, 11 KV panels, ACDB, DCDB, Neutral of power & station transformer.
MS Round 32mm dia, 6.21 Kg/mtr for earth mat, electodes for earth mat & delta earthing
G.I. Strip 65x6 mm.
G.I. Strip 35x6 mm.
Special earthing by treatment of soil with highly conducted material like combination of bentonite, conductive cement, coke dust, sodium carbonate, MgSo4, NaCl & CaCl2 as per ISS 3043-1987 as per annexure -A (including cost of all material & labor)
DC EQUIPMENTS
24 V Battery charger with boost & trickle charge 300AH rating automatic
24 V Battery set Maint. Free 300AH
DCDB 24 V
cable al 3.5x70 sq mm from station T/F to ACDB
LIGHTNING & ACCESSORIES
S.T. Pole 8 mtr. Long S.P.-10
LT PVC cable 4x10 sq. mm.
(iii) LT PVC Cable Aluminium 2X6 Sq MM(armoured)
Iron clad 30 Amps switch on the ST pole.
90W, LED lamp with control gear & mounting accessories (Branded Make,Philips ,oreva,havells,surya,syska,orpat,C&G)
MS item
MS (Rail, RS joist , MS Channel & MS angle, MS flat, MS plate, MS reinforcement bar as per RESSPO/Approved drawings) for Misc. structures for TG, BG, LA, CT, PT, Isolators, P.I., Fuse Sets stay support wire mesh fencing, gate support, cable trench, earthing cleat etc. design as per site conditions including fabrication, welding, nut & bolts, etc. complete in all respect. All galvenized.
Wire mesh fencing
Fabrication & supply of Wire mesh frame made of 8 SWG wires frame of 40x40x5 mm angle M.S. (3 mrx1.8 mr), MS flat & suitable 8mm plate & supply of 2 mtr long, 1.8 mtr high Wire mesh gate of 2 Nos panels with the help of 40 mm dia pipe & 35x5 mm MS flat, with proper provision of locking arrangements in two piece and 1.0x1.8 mtr gate Including all material & labour charges.
Bus bar material
ACSR Panther conductor
MS Plate 225x225x8 mm.
MS Plate 400x400x8 mm.
PG clamp Panther to Dog
i. For LA suitable for panther
ii. For Isolators suitable for panther
iii. For CT/PT suitable for panther/dog
iv. For SF-6, VCB suitable for panther
Rubber mat 1 mtr. wide x 2 mtr long and 12 mm thick to withstand 11 KV dielectric strength as per IS 5424-1969. Along the all equipments in Control Room.
Single line diagram board of S/s size 2½’x1½’ mica board with wooden frame, duly painted & writing.
Name plate of equipment TG, LI, BI, CT, CB, LA etc. (Size 9"x5" with white base, red border & letter written in red color)
Sundries items Cable tie, Alu lug, Copper lug & HT, LT tape, pvc compound, ferrule, pvc flexible pipe, paint writing on panels, HT LT diff size cable gland.
Civil
Gravel pitching of size 1/2" to 3/4"
Earthfilling in yard
Excavation of earth in mixed soil
Cement concreting in 1:4:8 ratio
Cement concreating in 1:3:6
Brick work in 1:4
Cement Plaster 1:4
Stone pad 300x300x75 mm.
Testing of equipments
Construction of Control Room Building Works at 33/11 KV GIS Sub Station.
Cost of 11KV Capacitor Bank
Civil Works for Transformer plinth, S/s Transformer structures, Cable trench, Pole
Gravel pitching of size 1/2" to 3/4"
Excavation of earth in mixed soil
Cement concreting in 1:4:8 ratio
Cement concreating in 1:3:6
RR Masonary 1:6
Brick work in 1:4
Cement Plaster 1:4
New 33 KV Underground Cable
3*300 XLPE Underground Cable (Double Ckt)
DOUBLE POLE STRUCTURE AS PER Annexure- B 8
Steel Tubular Poles 9.0 m long (STP 9.0 M-IS 410 SP-33) (Bottom Portion hot dip Galvanized) with MS Plate
MS angle 50x50x6mm with cable support with clamps bolts & nuts all galvanized, as per SBD
33 kV top channel 125x65x6mm 3.2 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs for Double Pole
PP & galvenized clamps for top portion of pole for Cable
Supply and laying of B-Class Heavy duty GI pipe as IS 1239 at Underground Road crossing, Nala crossings etc complete in all respects including Bell Mouth, long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends .GI Pipe 150 mm Dia
33 KV Polymer pin insulator with pin & nut
33 kV Danger Board with Clamp with N&B
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Galvenized Clamp for G.I pipe, Bolts & Warshers
Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07 Annexure C37
Stay complete (As per Annex-C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD
GI Stay Wire 7/8 SWG
33kv Stay Insulator
33 kv Stay Clamp (65x6 mm)with Nut, & Bolts all galvanized
Grouting with concreating of block size (600x600x300mm) CC ratio 1:3:6
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
Supply of 33kV (E) 3cx300mm2 XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL)
Supply of HDPE Pipe PE 80/100 PN6 160 mm dia for HT cable 3x300sqmm (with colour coding of HDPE pipe as approved by UPCL in order to differentiate other voltage cables laid in other pipes) including long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends
Laying of HT cable at the depth of about 1.5 meter as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using cable trench pullers (with Line tension Indicator) using conventional excavation method in HDPE pipe:including provision of cable Labels
Laying and Pulling of 33kV (E) 3cx300 mm2 XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL)
Laying of High -Density Polythylene(HDPE) Pipe PE 80/100 PN6 160 mm Dia for 3*300 sqmm XLPE Cable (colour of HDPE Pipe as per voltage level decided by UPCL) using conventional excavation method
Making of Trench using conventional excavation method as per Approved Drawing by UPCL. as per Approved Drawing by UPCL.
Supply and laying of B-Class Heavy duty GI pipe as IS 1239 at Underground Road crossing, Nala crossings etc complete in all respects including Bell Mouth, long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends .GI Pipe 150 mm Dia
33 KV T-Connector (As per Cable current Capacity )
Heat Shrinkable jointing kit for 33 kV 3cx300 Sq. mm. XLPE outdoor (including Extra Long Copper braid for Cable Earthing As Per Site Requriment)
Cable jointing kit straight through for 3cx300 Sq. mm. XLPE Cable
33 KV Lightening Arrester 10KA
Supply and installation of Chemical earthing station as per IS 3043 complete with GI earthing electrode ,Bentonite, . Conductor upto test link, test link,earthing chamber, 450x450 mm C.I. Manhole /Precast CC chamber etc.
MS item for holding gi pipe structure galvenized
Fabrication of m/s item
Supply and Fixing of Cable RCC Route Marker
HT Cable warning tape
New 33 KV Line with ACSR Conductor
33 KV New line with Dog conductor for Hills
33 kv single ckt A/B type tower Annexure C 39
Disc Fittings B&S type 70 KN for ACSR Dog
33 kV Compsite Polymer Disc Insulator B & S type
Fabricated galvanised 33 kv A/B type tower as per approved drawing.
Excavation of earth in mixed soil
setting of stub of 33 kv tower using tan plates etc complete work.as per approved drawing.
Cement concreating in 1:3:6
Number Plate with galvenized clamp, nut & bolt
Danger Board with galvenized clamps, nut & bolt
PG clamp/Wedge type for ACSR Dog
RYB coloured phase indicator
cross bridge damper for rabbit conductor
Bird guard for 33 kv tower
G.I fitting for earthwire 7/16 bolted
SINGLE POLE STRUCTURE As Per Annexure-C-20
Steel Tubular Poles 9.0 m long (STP 9.0 M-IS 410 SP-33) (Bottom Portion hot dip Galvanized) with MS Plate
33 kV, V Type cross arm made of MS Channel 125X65X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV Bracket made of MS Channel (125X65X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 KV Polymer pin insulator with pin & nut
Earth-wire clamp made of MS Flat 65x6mm for STP SP-33 with Nut & Bolts Warshers all galvanised
33 kV Danger Board with Clamp with N&B
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Clamp for Anti climbing device with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
SINGLE Section POLE STRUCTURE As Per Annexure-c20 single section
Steel Tubular Poles 9.0 m long (STP 9.0 M-IS 410 SP-33) (Bottom Portion hot dip Galvanized) with MS Plate
33 kV top channel 125x65x6mm 3.2 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs
33 kV Bracket made of MS Channel (125X65X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 KV Polymer pin insulator with pin & nut
Earth-wire clamp made of MS Flat 65x6mm for STP SP-33 with Nut & Bolts Warshers all galvanised
33 kV Compsite Polymer Disc Insulator B & S type
Disc Fittings B&S type 70 KN for ACSR Dog
33 kV Danger Board with Clamp with N&B
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Clamp for Anti climbing device with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
DOUBLE POLE STRUCTURE As Per Annexure-C-21 A
Steel Tubular Poles 9.0 m long (STP 9.0 M-IS 410 SP-33) (Bottom Portion hot dip Galvanized) with MS Plate
33 kV top channel 125x65x6mm 3.2 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs for Double Pole
Cross bracing Set 65x65x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
33 KV Polymer pin insulator with pin & nut
33 KV E Clamp with Nut & bolts all Galvanised
33 KV GI fish Plate
33 kV Compsite Polymer Disc Insulator B & S type
Disc Fittings B&S type 70 KN for ACSR Dog
Earth-wire clamp made of MS Flat 65x6mm for STP SP-33 with Nut & Bolts Warshers all galvanised
33 kV Danger Board with Clamp with N&B
PG clamp/Wedge type for ACSR Dog
Aluminum Binding wire & tape
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Clamp for Anti climbing device with Nuts, Bolts & Warshers all galvanized.
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
FOUR POLE STRUCTURE As Per Annexure-C-22 A
Steel Tubular Poles 9.0 m long (STP 9.0 M-IS 410 SP-33) (Bottom Portion hot dip Galvanized) with MS Plate
33 kV top channel 125x65x6mm 3.2 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs
Cross bracing Set 65x65x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
33 KV Polymer pin insulator with pin & nut
33 KV E Clamp with Nut & bolts all Galvanised
33 kV Compsite Polymer Disc Insulator B & S type
Disc Fittings B&S type 70 KN for ACSR Dog
Earth-wire clamp made of MS Flat 65x6mm for STP SP-33 with Nut & Bolts Warshers all galvanised
33 kV Danger Board with Clamp with N&B
PG clamp/Wedge type for ACSR Dog
Aluminum Binding wire & tape
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Clamp for Anti climbing device with Nuts, Bolts & Warshers all galvanized.
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
ACSR DOG CONDUCTOR With 3% Sag As Per Annexure-C-23
ACSR Dog Conductor for Phase with 3% sag.
EARTH WIRE 7/1.6mm 16 SWG with 3% sag.
Jointing Sleeve for Dog Conductor
GUARDING OF LINE AS PER Annexure -C-17 (DP)
Guarding channel 100x50x6 mm,3750 mm long with holding clamp, nut & bolts etc. all galvanized (For Double pole)
PP of suitable size for Top portion of STP-410, SP-33 Pole
GI Eye Bolt 16mm dia, 236mm long for guarding
8 SWG GI wire
GI Wire 6 SWG
G.I. Wire No. 16 SWG for binding
GUARDING OF LINE AS PER Annexure -C-17 A (SP)
Guarding channel 100x50x6 mm,2000 mm long with holding clamp, nut & bolts etc. all galvanized (For Single pole)
PP of suitable size for Top portion of STP-410, SP-33 Pole
GI Eye Bolt 16mm dia, 236mm long for guarding
8 SWG GI wire
GI Wire 6 SWG
G.I. Wire No. 16 SWG for binding
Misc. material required for passing 11 kv/LT conductor from 33 KV line poles, connecting with old existing 33 KV line, Cost of dismentling /shifting of 11 KV /LT line pole Misc!A1
MS channel 100x50 mm galvenized
MS angle 50x50x6 mm galvenized
11 KV Polymer Disc Insulator B&S type
Disc Fittings B&S type 70 KN for ACSR Dog
11 kV Polymer Pin Insulator complete
Stay clamp with nut & bolt galvenized
33 KV Polymer pin insulator with pin & nut
ACSR Rabbit Conductor
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V-type channel X-arm galvenized
PP & galvenized clamp for SP-23
Galvenized Bracing clamp (top & bottom) for SP-23/SP-33
Earth-wire clamp made of MS Flat 50x8mm for STP SP-23 with Nut & Bolts Warshers all galvanised
LT shackle insulator
Galvenized Clamp for LT insulator mid portion SP 23 STP
Shifting realignment of 11 KV SP,DP /LT line including dismentling,re-erection,re-stringing complete work
'special type bracket'!A1 c24
MS CHANNEL 125x65x6MM all galvanized with pp clamp nut & bolt
MS CHANNEL 100x50x6MM all galvanized with pp clamp nut & bolt
MS ANGLE 75x75x6 MM all galvanized with pp clamp nut & bolt
33 KV F-BRACKET all galvanized
Stay complete (As per Annex-C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD
GI Stay Wire 7/8 SWG
33kv Stay Insulator
33 kv Stay Clamp (65x6 mm)with Nut, & Bolts all galvanized
Grouting with concreating of block size (600x600x300mm) CC ratio 1:3:6
Cost of pole plinth for protection of line
FOR single polec-38
Erection work for Single pole
Excavation of earth in mix soil, soft rock, hard rock
Cement concreting in 1:4:8 ratio
R.R. stone masonary work in 1:6 ratio cement mortar
for Double pole C-38
Erection work for Double pole
Excavation of earth in mix soil, soft rock, hard rock
Cement concreting in 1:4:8 ratio
R.R. stone masonary work in 1:6 ratio cement mortar
for Four pole c-38
Erection work for Four pole
Excavation of earth in mix soil, soft rock, hard rock
Cement concreting in 1:4:8 ratio
R.R. stone masonary work in 1:6 ratio cement mortar
New 11 KV line Underground Cable
3*120 XLPE Underground Cable (Single Circuit)
DOUBLE POLE STRUCTURE AS PER Annexure
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV top channel 100x50x6mm 2.2 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs(For double pole)
PP of suitable size for Top portion of STP-410, SP-23 Pole
Cross bracing Set 50x50x6mm with Belting angle of 50x50x6mm with clamps bolts & nuts all galvanized, as per SBD
Base Channel (100X50X6) 2.2 mtr. Long with Clamps and fittings as per SBD specs
11 kV Polymer Pin Insulator complete
11 KV Danger board with galvenized clamp
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Clamp for Anti climbing device with Nuts, Bolts & Warshers all galvanized.
Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 6 SWG with Bolts Clamp, Washers & Nuts complete all galvenized.
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Stays Complete 11 kV Stay
11 kV Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm) with Nuts, Bolts & warshers all galvanized
Grouting with concreating of block size (600x600x300mm) CC ratio 1:3:6
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
Supply and laying of B-Class Heavy duty GI pipe as IS 1239 at Underground Road crossing, Nala crossings etc complete in all respects including Bell Mouth, long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends .GI Pipe 150 mm Dia
Supply of 11kV (E) 3cx120mm2 XLPE cable (Cable outer sheet colour as per voltage level decided by UPCL)
Supply of HDPE Pipe 160 mm dia for HT cable 3x120sqmm (with colour coding of HDPE pipe as approved by UPCL in order to differentiate other voltage cables laid in other pipes) including long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends
Laying of HT cable at the depth of about 1.2 meter as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using cable trench pullers (with Line tension Indicator) using conventional excavation method in HDPE, GI pipe:including provision of cable Labels
Pulling and Laying of 11kV (E) 3cx120mm2 XLPE cable (Cable outer sheet colour as per voltage level decided by UPCL)
Laying of High -Density Polythylene(HDPE) Pipe 160 mm Dia for 11kV 3cx120 sqmm XLPE Cable (colour of HDPE Pipe as per voltage level decided by UPCL) using conventional excavation method
Making of Trench using conventional excavation method as per Approved Drawing by UPCL. as per Approved Drawing by UPCL.
Supply and laying of B-Class Heavy duty GI pipe as IS 1239 at Underground Road crossing, Nala crossings etc complete in all respects including Bell Mouth, long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends .GI Pipe 100 mm Dia
Heat Shrinkable jointing kit for 11 kV 3cx120 Sq. mm. XLPE outdoor (including Extra Long Copper braid for Cable Earthing As Per Site Requriment)
Cable jointing kit straight through for 3cx120 Sq. mm. XLPE Cable
11 KV T-Connector (As per Cable current Capacity )
Lightening Arrestors Polymer (9kV, 5kA)
Supply and installation of Chemical earthing station as per IS 3043 complete with GI earthing electrode ,Bentonite, . Conductor upto test link, test link,earthing chamber, 450x450 mm C.I. Manhole /Precast CC chamber etc.
Supply and Fixing of Cable RCC Route Marker
New 11 KV Line with ACSR Conductor
11 KV New line with Rabbit conductor SP-23
11 KV single ckt A/B type tower Annexure Tower
11 kV Disc Fittings B&S type 45 KN for ACSR Rabbit
11 KV Polymer Disc Insulator B&S type
Fabricated galvanised 11 kv A/B type tower as per approved drawing.
Excavation of earth in mixed soil
setting of stub of 33 kv tower using tan plates etc complete work.as per approved drawing.
Cement concreating in 1:3:6
Number Plate with galvenized clamp, nut & bolt
Danger Board with galvenized clamps, nut & bolt
PG clamp/Wedge type for ACSR Rabbit
RYB coloured phase indicator
cross bridge damper for rabbit conductor
Bird guard for 11 kv tower
G.I fitting for earthwire 7/16 bolted
Single Pole as per Annexure
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator complete
11 KV Danger board with galvenized clamp
Earth-wire clamp made of MS Flat 50x8mm for STP SP-23 with Nut & Bolts Warshers all galvanised
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Clamp for Anti climbing device with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 6 SWG with Bolts Clamp, Washers & Nuts complete all galvenized.
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
Single Section Pole as per Annexure
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV MS channel 100x50x6mm 1.13 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs
PP of suitable size for Top portion of STP-410, SP-23 Pole
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator complete
11 KV Polymer Disc Insulator B&S type
11 kV Disc Fittings B&S type 45 KN for ACSR Rabbit
Earth-wire clamp made of MS Flat 50x8mm for STP SP-23 with Nut & Bolts Warshers all galvanised
PG clamp/Wedge type for ACSR Rabbit
11 KV Danger board with galvenized clamp
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Clamp for Anti climbing device with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 6 SWG with Bolts Clamp, Washers & Nuts complete all galvenized
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
Double Pole structure as per Annexure
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV top channel 100x50x6mm 2.2 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs(For double pole)
PP of suitable size for Top portion of STP-410, SP-23 Pole
Cross bracing Set 50x50x6mm with Belting angle of 50x50x6mm with clamps bolts & nuts all galvanized, as per SBD
11 kV Polymer Pin Insulator complete
GI Fish Plate 50x8mm for 11 kv DP
11 KV Polymer Disc Insulator B&S type
11 kV Disc Fittings B&S type 45 KN for ACSR Rabbit
Earth-wire clamp made of MS Flat 50x8mm for STP SP-23 with Nut & Bolts Warshers all galvanised
11 KV Danger board with galvenized clamp
PG clamp/Wedge type for ACSR Rabbit
Aluminum Binding wire & tape
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Clamp for Anti climbing device with Nuts, Bolts & Warshers all galvanized.
Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 6 SWG with Bolts Clamp, Washers & Nuts complete all galvenized
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
Four Pole structure as per Annexure
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV top channel 100x50x6mm 2.2 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs for SP-23
PP of suitable size for Top portion of STP-410, SP-23 Pole
Cross bracing Set 50x50x6mm with Belting angle of 50x50x6mm with clamps bolts & nuts all galvanized, as per SBD
11 kV Polymer Pin Insulator complete
11 kV E Clamp made of MS Channel (50X8)mm with Bolts & Nuts All galvenized
11 kV Disc Fittings B&S type 45 KN for ACSR Rabbit
11 KV Polymer Disc Insulator B&S type
Earth-wire clamp made of MS Flat 50x8mm for STP SP-23 with Nut & Bolts Warshers all galvanised
11 KV Danger board with galvenized clamp
PG clamp/Wedge type for ACSR Rabbit
Aluminum Binding wire & tape
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Clamp for Anti climbing device with Nuts, Bolts & Warshers all galvanized.
Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 6 SWG with Bolts Clamp, Washers & Nuts complete all galvenized
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
ACSR Rabbit Conductor as per Annexure
ACSR Rabbit Conductor
EARTH WIRE 7/1.6mm 16 SWG with 3% sag.
Jointing Sleeve for Rabbit Conductor
Guarding of 11 KV line. for DP as per Annexure
Guarding channel 100x50x6 mm,2700 mm long with holding clamp,nut & bolts etc. all galvanized as per SBD (DP)
PP of suitable size for Top portion of STP-410, SP-23 Pole
GI Wire 6 SWG
8 SWG GI wire
GI Eye Bolt 16mm dia, 236mm long for guarding
G.I. Wire No. 16 SWG for binding
Guarding of 11 KV line. for SP as per Annexure
Guarding channel 100x50x6 mm,1600 mm long with holding clamp, nut & bolts etc. all galvanized as per SBD (SP)
PP of suitable size for Top portion of STP-410, SP-23 Pole
GI Wire 6 SWG
8 SWG GI wire
GI Eye Bolt 16mm dia, 236mm long for guarding
G.I. Wire No. 16 SWG for binding
Stay complete as per Annexure
11 kV Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm) with Nuts, Bolts & warshers all galvanized
Grouting with concreating of block size (600x600x300mm) CC ratio 1:3:6
Special type bracket for 11 KV
MS CHANNEL 100x50x6MM all galvanized
MS Angle 65x65x6MM all galvanized
MS CHANNEL 100x50x6MM all galvanized
Special Bracket PP & CLAMP with Nut & Bolt all galvanized
11 KV F-BRACKET all galvanized
Cost of pole plinth for protection of line
for Single pole
Erection work for Single pole
Excavation of earth in mix soil, soft rock, hard rock
Cement concreting in 1:4:8 ratio
R.R. stone masonary work in 1:6 ratio cement mortar
for Double pole
Erection work for Double pole
Excavation of earth in mix soil, soft rock, hard rock
Cement concreting in 1:4:8 ratio
R.R. stone masonary work in 1:6 ratio cement mortar
for Four pole
Erection work for Four pole
Excavation of earth in mix soil, soft rock, hard rock
Cement concreting in 1:4:8 ratio
R.R. stone masonary work in 1:6 ratio cement mortar
New LT Line: Proposed Cabling Works for New DTR New LT Line with AB Cable
New LT line with Insulated ABC of 3x95+1x70+1x16 Sq.mm. for Hills
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
L.T. Insulation Piercing Connectors (16 sq.mm. - 16 sq.mm.) suitable for street light connection
PG Connector/Wedge type 70 Sqmm.
Mid span jointing sleeves (95 Sq.mm.)
Mid span jointing sleeves (16 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x95+1x70+1x16 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
1x16 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
LT Stay complete Annexure
11 kV Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm) with Nuts, Bolts & warshers all galvanized
Grouting with concreating of block size (600x600x300mm) CC ratio 1:3:6
Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG with Bolts Clamp, Washers & Nuts complete all galvenized
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
New DTR
Plinth Mounted New DTR 100 KVA
11/0.433 kV 100 kVA Distribution Transformer (Level 2 New)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
MS Channel 125x65x6mm, 2.800mtr. long (Top Channel) with all fixing arrangment Clamps, Nuts & Bolts all galvanized as per SBD specs
PP of suitable size for Top portion of STP-410, SP-23 Pole
MS Channel 125x65x6mm, 1.300 mtr. long (Tee off) with clamps ,Bolt and nuts all galvanized as per SBD specs
MS Channel 125x65x6mm, 2.800 mtr. Long (for Transformer Base) with all fixing arrangment Clamps,Nuts & Bolts all galvanized as per SBD specs
PP of suitable size for Bottom portion of STP-410, SP-23 Pole
11 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type, Gang Operated, AB Switch
MS Channel 100x50x6mm 2 no. 2.8 mtr. Long, Clamp,Nuts&Bolts all galvanized as per SBD specs for AB Switch.
11 kV Drop out fuse set (25 kVA)
MS Channel 100x50x6mm 2.8 mtr. Long, Clamp,Nuts&Bolts all galvanized as per SBD specs for DO fuse set.
PP of suitable size for Middle portion of STP-410, sp-23 Pole
11 kV Polymer Pin Insulator complete
GI Fish Plate 50x8mm for 11 kv DP
11 KV Polymer Disc Insulator B&S type
11 kV Disc Fittings B&S type 45 KN for ACSR Rabbit
LT panel with protection equipment along with MCCB, Earth Fault Relay (EFR) etc. including fixing arrangement for 100kVA T/F.
DTR Metering Cubicals with Three Phase, Four Wire, 0.5 Class, Energy Meter for 3-Phase 100kVA Distribution Transformer
LTDB & DTR Mereting channel 100x50x6mm 2.8 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs
ACSR Rabbit Conductor
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Clamp for Anti climbing device with Nuts, Bolts & Warshers all galvanized.
11 kV Danger Board with Clamp with N&B
Lightening Arrestors Polymer (9kV, 5kA)
Compound filled earthing/Chemical Earthing(with GI Strip 25x3mm for Neutral Earthing of Transformer Annexure C 37 A
Compound filled earthing/Chemical Earthing(with GI Strip 25x3mm for Neutral Earthing of Transformer
G.I. Strip 35x6mm
Compound filled earthing/Chemical Earthing of Transformer Body(with GI strip 25x3mm),Other structure& Equipment( with GI Wire of 8 SWG) Annexure C 37 B
Compound filled earthing/Chemical Earthing of Transformer Body(with GI strip 25x3mm),Other structure& Equipment( with GI Wire of 8 SWG)
8 SWG GI wire
G.I. Strip 35x6mm
Compound filled earthing/Chemical Earthingof Lightning Arrestor with GI Strip 25x3mm Annexure C 37 C
Compound filled earthing/Chemical Earthingof Lightning Arrestor with GI Strip 25x3mm (Double earthing).
G.I. Strip 35x6mm
Aluminum lugs HT side
Aluminum crimping lugs LT side
70 Sq.mm.,single core `XLPE insulated un-armoured aluminium conductor cable
120 Sq.mm.,single core `XLPE insulated un-armoured aluminium conductor cable
Stay complete (As per Annex-F-15)
11 kV Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm) with Nuts, Bolts & warshers all galvanized
Grouting with concreating of block size (600x600x300mm) CC ratio 1:3:6
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07 Annexure C37
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
Construction of plinth for Transformer(3x3x1 mtr mtr) above GL with shed.
Excavation of earth in mixed soil
Cement concreating in 1:3:6
RR Masonary 1:3
Sign Board
Sign Board 6x4 feet (lengh x breadth)
Sign Board 6x4 feet (lengh x breadth) made of MS sheet 14 Gauge(1.6mm thickness) with angle suport of (3"x3",6mm) and height of board 6 feet fromm ground level to bottom of board and length of angle to be buried in the ground 1.50 feet with 1 feet hole pass inside,painting on board ( enamel paint with red oxide base coat)and printing on board (colour printing by Screen printing method)
Sign Board 4x3 feet (lengh x breadth)
Sign Board 4x3 feet made of MS sheet 14 Gauge(1.6mm thickness) with angle suport of (3"x3",6mm) and height of board 6 feet fromm ground level to bottom of board and length of angle to be buried in the ground 1.50 feet with 1 feet hole pass inside,painting on board ( enamel paint with red oxide base coat) to indicate Name of scheme, name of implemention agency and capacity of S/s
Description of Work / Item(s)
Amount
New Substation 2x5 MVA
33 KV MATERIAL
Electricals Equipments
33 KV Lightening Arrester 10KA
MS Plate 300x300x8 mm.
HT Cable warning tape
33kV 3 Pole 1250A Line Isolator (Verticle Type)complete set.
33 KV Bus isolator
33 KV Fuse set
33 KV Aluminium 3x300 sq. mm. XLPE cable
Heat Shrinkable jointing kit for 33 kV 3cx300 Sq. mm. XLPE outdoor (including Extra Long Copper braid for Cable Earthing As Per Site Requriment)
33kV Indoor cable termination kit (3CX300 SQMM)
11kV 3CX240 SQMM XLPE Cable and its laying in Trenches(double ckt)
11kV 3CX120 SQMM XLPE Cable and its laying in Trenches
33 kV 3CX70 SQMM XLPE Cable and its laying (double ckt)
Heat Shrinkable jointing kit for 11 kV 3cx120 Sq. mm. XLPE outdoor (including Extra Long Copper braid for Cable Earthing As Per Site Requriment)
11kV Indoor Cable termination kit (3CX120 SQMM)
11kV Outdoor Cable termination kit (3CX240 SQMM)
11kVindoor Cable termination kit (3CX240 SQMM)
33kV Outdoor Cable termination kit (3CX70SQMM)
33 kV Indoor Cable termination kit (3CX70SQMM)
5 MVA, 33/11 KV Power Transformer with On Load Tap Changer with complete RTCC & related accessories
63 kVA, 33/0.4 KV Oil Cooled Type for Substation supply.
GI pipe 4" dia. 3mtr long ( for double pole & bus bar gantry)
Clamp of MS Flat 50x6 mm. of suitable size for holding 6" & 4" dia. Pipe All galvenized
11 kv 9kV, 10kA Outdoor type Lighting Arrestors
11kV 800A Outdoor Type Isolators (TPMO Switch)
33kV Gas Insulated Switchgear (GIS) with Vacuum Circuit Breaker Panel Board Indoor type (With termination kits) CT, PT, Microprocessor based Protection Relay, Metering equipments, Extinsible both sitdes, Bus Bars etc, consist of:
Incomer/Outgoing Panel with CT Ratio 600-300/5-5A
Outgoing Panel with CT Ratio 600-300/5-5A
11kV Gas Insulated Switchgear (GIS) with Vacuum Circuit Breaker Panel Board Indoor type (with termination kits) with required CT, PT, Microprocessor based Protection Relay, Metering equipments, Extinsible both sitdes, Bus Bars etc, consist of:
Incomer Panel with CT Ratio 600-300/5-5A
Outgoing Panel with CT Ratio 400-200/5-5A
11 KV Bus Coupler Panel
Bus Riser Panel
LT Power & Control Cable from Station T/F to AC DB along with suitable crimping lugs and its laying:
LT Cable Al. 3.5Cx70 Sq.mm.PVC for Stn. T/F to ACDB.
LT PVC cable 4x10 sq. mm.
(iii) LT PVC Cable Aluminium 2X6 Sq MM(armoured)
i. 10C x 2.5 Sq. mm.
ii. 4C x 2.5 Sq. mm.
iii 2C x 2.5 Sq. mm.
(v) Sundries items Cable tie, Alu lug, Copper lug & HT, LT tape, pvc compound, ferrule, pvc flexible pipe, paint writing on panels, HT LT diff size cable gland.with coppper lugs & other miscellaneous material at substation
Battery & Charger
110V Battery Set (300AH) - Tubular type
110V Battery Charger (300AH) with Automatice boost and trickle charge.
110V DCDB
AC Power distribution Board
Earthing of Substation and equipments
(i) 32MM MS Round
(ii) 65X6MM GI Strip
(iii) 40X6 GI Strip
M.S. Bolt & Nut Off size all galvenized
Special earthing by treatment of soil with highly conducted material like combination of bentonite, conductive cement, coke dust, sodium carbonate, MgSo4, NaCl & CaCl2 as per ISS 3043-1987 as per annexure -A (including cost of all material & labor)
BUS BAR & CONNECTORS AT 33/11 KV SUB-STATION
ACSR Panther conductor
ACSR Weasel conductor
33 KV Polymer pin insulator with pin & nut
Connectors suitable for Panther
1. For LA suitable for panther
2. For T/F suitable for panther & HT side
3. For T/F suitable for LT side
2. For Isolators(For Panther)
Connectors suitable for Dog
1. For LA for Dog
2. For Isolators(For Dog)
3. For station transformer suitable for weasel
PG clamp/Wedge type for ACSR Dog
E-Clamps with nut & bolt all galvenized
Flexible copper connection on neutral bushing of power & station transformer 500X50 mm heavy duty with copper lug at ends.
Making cable trench.including fabrication, fixing of MS angle 50x50x6 mm size (excluding the cost of MS Angle/ MS bar) on side edge with all excavation of size (lxbxh) 70x1x1.5, CC work, brick work, fixing of cable support angle one/two tier as required with stopper arrangement at 0.5 mtr gap throughout the length of the trench, making of cable trench covers with MS Bar welded mesh angle frame of MS angle 40x40x6 mm. with lifting hooks, fixing of perforated tray complete as per drawing including cost of sand, cement, bricks, metal (gitti) etc.
Cost of fire & safety equipments of Substation
(i) CO2 type ire Extingusher confirming IS 2878-1976 and cylinder fully charged of 4.5kg capacity
(ii) Foam type Fire Extingusher portable type 5 Lit capacity hang on wall with bracket complete as required.
(iii) Metal fire bucket with sand
(iv) Stand of chuggi type of MS Angle 50X50X6 MM with top covered by MS sheet 1.5MM thickness duly painted with Red color including fabrication complete
Mics items for Substation like:
Rubber mat Class C 3 mm Synthetic Insulating Mat- Confirming to IS 15652 : 2006. Along the all equipments in Control Room.
Danger board
Shut down / Break down board (Bi-lingual Hindi & English)
HT Hand Gloves
Galvenised Perforated Cable Tray
(iii) 100MM
DP structure S.T. Pole 11 mtr. Long SP-55(Bottom Portion hot dip Galvanized) for ststion t/f with all fittings, channels etc. complete work
P.P. & galvenized Clamps for S.T. Pole SP-55 with nut & bolts
Clamp of required size for holding cable supporting angle, pipe, cable & bus isolator handle on double pole & bus bar gantry
Stone Pad 300x300x75
GI pipe 4" dia. 3mtr long ( for double pole & bus bar gantry)
Insulators for holding earthing strip of lightening arrestor & transformer neutral
G.I.pipe 40/50 mm out.dia. & thickness 4/5 mm, 6 mtr. Long for making opearting mechanism for vertical bus isolator
MS Earthing rod 20x2500mm galvenized
GI Wire 6 SWG
Incoming/Outgoing 33KV/11kV Double Pole Strcuture complete in all respect including MS Channel, Earth Rod, Stay Set, Polymer Isnulators, Dics Fittings, GI wire,PP& clamps, fuse set,TPMO SWITCH, GI Pipe 4"X3.0Mt, MS Plate,complete structure for S/S T/F as per electricity noms complete
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 KV Polymer Disc Insulator B&S type
11 KV disc fitting for weasal Conductor
11 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type, Gang Operated, AB Switch
11 kV Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD
GI Stay Wire 7/10 SWG
11 kv 9kV, 10kA Outdoor type Lighting Arrestors
11 KV fuse set.
P.P. & galvenized Clamps for S.T. Pole
Galvenized Bracing Clamp for ST Pole
Galvenized Stay clamp for ST Pole
Galvenized Clamp of required size for holding cable supporting angle, cable & TPMO handle
Name plate of feeder with galvenized clamp
11 KV Danger board with galvenized clamp
GI pipe 4" dia. 3mtr long ( for double pole & bus bar gantry)
MS strcuture steel, angle, channel, Rail, MS Bar, RS Joist, MS Plate. All galvenized
Fabrication & supply of Wire mesh frame made of 8 SWG wires frame of 40x40x5 mm angle M.S. (3 mrx1.8 mr), MS flat & suitable 8mm plate & supply of 2 mtr long, 1.8 mtr high Wire mesh gate of 2 Nos panels with the help of 40 mm dia pipe & 35x5 mm MS flat, with proper provision of locking arrangements in two piece and 1.0x1.8 mtr gate Including all material & labour charges.
Testing of S/s
Construction of 33KV Bay
33 KV Material
Control Panel Inc 33 KV single Feeder 24 V,
33 KV, 1250A, 3 Phase O/D type , VCB 24 V DC.
33kV 3 Pole 1250A Line Isolator (Verticle Type)complete set.
33 KV Bus isolator
33 KVCT Out door with junction box, 33 KV CTR 400-200/1-1-1 A
Junction box for CT
33 KV Lightening Arrester 10KA
Heat Shrinkable jointing kit for 33 kV 3cx300 Sq. mm. XLPE outdoor (including Extra Long Copper braid for Cable Earthing As Per Site Requriment)
33 KV Post Insulator
HT Cable warning tape
G.I pipe 6"dia
Laying of 33 KV Cable by excavation, depth 1 mtr of cable trench in mixed soil and c:c road, levelling/dressing at base, properly laying of the cable by placing bricks on both side & top of the cable filling of 250 mm layer sand from the top so as to cover the cable completely and then filing excavated soil upto 300 mm then spreading of cable warning tape & covering of the trench completely with excavated mixed soil, compacting the soil upto ground level including cost of sand, first class bricks, etc.
33 KV Aluminium 3x300 sq. mm. XLPE cable
LT control cable
LT Control Cable
i. 10C x 2.5 Sq. mm.
ii. 4C x 2.5 Sq. mm.
iii 2C x 2.5 Sq. mm.
Perforated tray 400/ mm width for cable trench galvenized
Perforated tray 300 mm width for cable trench galvenized
Perforated tray 100 mm width for cable trench galvenized
Making cable trench.including fabrication, fixing of MS angle 50x50x6 mm size (excluding the cost of MS Angle/ MS bar) on side edge with all excavation of size (lxbxh) 70x1x1.5, CC work, brick work, fixing of cable support angle one/two tier as required with stopper arrangement at 0.5 mtr gap throughout the length of the trench, making of cable trench covers with MS Bar welded mesh angle frame of MS angle 40x40x6 mm. with lifting hooks, fixing of perforated tray complete as per drawing including cost of sand, cement, bricks, metal (gitti) etc.
Earthing work
Straightening and laying of Earth mat of 32 mm M S round 0.6 mtr deep in mixed soil according to drawing or as per UPCL direction or/and as per site requirement. Making T-joints, cross joint and Lap joints by welding of M S round bar together using cleats of MS Angles 65x65x6 mm, chipping the slag and painting of the joints with black bitumen paint (including supply of paint) to avoid rusting. Cutting & making electrode 2.5 mtr long with conical pointed bottom and driving of the electrode remains 450 mm below ground level. Backfilling of soil in trenches, ramming and leveling of trench properly after completion of eartmat and earthing work is complete. Making of Delta/Bridge earthing for structure/panels i.e. LA, 11 KV panels, ACDB, DCDB, Neutral of power & station transformer.
MS Round 32mm dia, 6.21 Kg/mtr for earth mat, electodes for earth mat & delta earthing
G.I. Strip 65x6 mm.
G.I. Strip 35x6 mm.
Special earthing by treatment of soil with highly conducted material like combination of bentonite, conductive cement, coke dust, sodium carbonate, MgSo4, NaCl & CaCl2 as per ISS 3043-1987 as per annexure -A (including cost of all material & labor)
DC EQUIPMENTS
24 V Battery charger with boost & trickle charge 300AH rating automatic
24 V Battery set Maint. Free 300AH
DCDB 24 V
cable al 3.5x70 sq mm from station T/F to ACDB
LIGHTNING & ACCESSORIES
S.T. Pole 8 mtr. Long S.P.-10
LT PVC cable 4x10 sq. mm.
(iii) LT PVC Cable Aluminium 2X6 Sq MM(armoured)
Iron clad 30 Amps switch on the ST pole.
90W, LED lamp with control gear & mounting accessories (Branded Make,Philips ,oreva,havells,surya,syska,orpat,C&G)
MS item
MS (Rail, RS joist , MS Channel & MS angle, MS flat, MS plate, MS reinforcement bar as per RESSPO/Approved drawings) for Misc. structures for TG, BG, LA, CT, PT, Isolators, P.I., Fuse Sets stay support wire mesh fencing, gate support, cable trench, earthing cleat etc. design as per site conditions including fabrication, welding, nut & bolts, etc. complete in all respect. All galvenized.
Wire mesh fencing
Fabrication & supply of Wire mesh frame made of 8 SWG wires frame of 40x40x5 mm angle M.S. (3 mrx1.8 mr), MS flat & suitable 8mm plate & supply of 2 mtr long, 1.8 mtr high Wire mesh gate of 2 Nos panels with the help of 40 mm dia pipe & 35x5 mm MS flat, with proper provision of locking arrangements in two piece and 1.0x1.8 mtr gate Including all material & labour charges.
Bus bar material
ACSR Panther conductor
MS Plate 225x225x8 mm.
MS Plate 400x400x8 mm.
PG clamp Panther to Dog
i. For LA suitable for panther
ii. For Isolators suitable for panther
iii. For CT/PT suitable for panther/dog
iv. For SF-6, VCB suitable for panther
Rubber mat 1 mtr. wide x 2 mtr long and 12 mm thick to withstand 11 KV dielectric strength as per IS 5424-1969. Along the all equipments in Control Room.
Single line diagram board of S/s size 2½’x1½’ mica board with wooden frame, duly painted & writing.
Name plate of equipment TG, LI, BI, CT, CB, LA etc. (Size 9"x5" with white base, red border & letter written in red color)
Sundries items Cable tie, Alu lug, Copper lug & HT, LT tape, pvc compound, ferrule, pvc flexible pipe, paint writing on panels, HT LT diff size cable gland.
Civil
Gravel pitching of size 1/2" to 3/4"
Earthfilling in yard
Excavation of earth in mixed soil
Cement concreting in 1:4:8 ratio
Cement concreating in 1:3:6
Brick work in 1:4
Cement Plaster 1:4
Stone pad 300x300x75 mm.
Testing of equipments
Construction of Control Room Building Works at 33/11 KV GIS Sub Station.
Cost of 11KV Capacitor Bank
Civil Works for Transformer plinth, S/s Transformer structures, Cable trench, Pole
Gravel pitching of size 1/2" to 3/4"
Excavation of earth in mixed soil
Cement concreting in 1:4:8 ratio
Cement concreating in 1:3:6
RR Masonary 1:6
Brick work in 1:4
Cement Plaster 1:4
New 33 KV Underground Cable
3*300 XLPE Underground Cable (Double Ckt)
DOUBLE POLE STRUCTURE AS PER Annexure- B 8
Steel Tubular Poles 9.0 m long (STP 9.0 M-IS 410 SP-33) (Bottom Portion hot dip Galvanized) with MS Plate
MS angle 50x50x6mm with cable support with clamps bolts & nuts all galvanized, as per SBD
33 kV top channel 125x65x6mm 3.2 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs for Double Pole
PP & galvenized clamps for top portion of pole for Cable
Supply and laying of B-Class Heavy duty GI pipe as IS 1239 at Underground Road crossing, Nala crossings etc complete in all respects including Bell Mouth, long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends .GI Pipe 150 mm Dia
33 KV Polymer pin insulator with pin & nut
33 kV Danger Board with Clamp with N&B
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Galvenized Clamp for G.I pipe, Bolts & Warshers
Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07 Annexure C37
Stay complete (As per Annex-C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD
GI Stay Wire 7/8 SWG
33kv Stay Insulator
33 kv Stay Clamp (65x6 mm)with Nut, & Bolts all galvanized
Grouting with concreating of block size (600x600x300mm) CC ratio 1:3:6
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
Supply of 33kV (E) 3cx300mm2 XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL)
Supply of HDPE Pipe PE 80/100 PN6 160 mm dia for HT cable 3x300sqmm (with colour coding of HDPE pipe as approved by UPCL in order to differentiate other voltage cables laid in other pipes) including long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends
Laying of HT cable at the depth of about 1.5 meter as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using cable trench pullers (with Line tension Indicator) using conventional excavation method in HDPE pipe:including provision of cable Labels
Laying and Pulling of 33kV (E) 3cx300 mm2 XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL)
Laying of High -Density Polythylene(HDPE) Pipe PE 80/100 PN6 160 mm Dia for 3*300 sqmm XLPE Cable (colour of HDPE Pipe as per voltage level decided by UPCL) using conventional excavation method
Making of Trench using conventional excavation method as per Approved Drawing by UPCL. as per Approved Drawing by UPCL.
Supply and laying of B-Class Heavy duty GI pipe as IS 1239 at Underground Road crossing, Nala crossings etc complete in all respects including Bell Mouth, long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends .GI Pipe 150 mm Dia
33 KV T-Connector (As per Cable current Capacity )
Heat Shrinkable jointing kit for 33 kV 3cx300 Sq. mm. XLPE outdoor (including Extra Long Copper braid for Cable Earthing As Per Site Requriment)
Cable jointing kit straight through for 3cx300 Sq. mm. XLPE Cable
33 KV Lightening Arrester 10KA
Supply and installation of Chemical earthing station as per IS 3043 complete with GI earthing electrode ,Bentonite, . Conductor upto test link, test link,earthing chamber, 450x450 mm C.I. Manhole /Precast CC chamber etc.
MS item for holding gi pipe structure galvenized
Fabrication of m/s item
Supply and Fixing of Cable RCC Route Marker
HT Cable warning tape
New 33 KV Line with ACSR Conductor
33 KV New line with Dog conductor for Hills
33 kv single ckt A/B type tower Annexure C 39
Disc Fittings B&S type 70 KN for ACSR Dog
33 kV Compsite Polymer Disc Insulator B & S type
Fabricated galvanised 33 kv A/B type tower as per approved drawing.
Excavation of earth in mixed soil
setting of stub of 33 kv tower using tan plates etc complete work.as per approved drawing.
Cement concreating in 1:3:6
Number Plate with galvenized clamp, nut & bolt
Danger Board with galvenized clamps, nut & bolt
PG clamp/Wedge type for ACSR Dog
RYB coloured phase indicator
cross bridge damper for rabbit conductor
Bird guard for 33 kv tower
G.I fitting for earthwire 7/16 bolted
SINGLE POLE STRUCTURE As Per Annexure-C-20
Steel Tubular Poles 9.0 m long (STP 9.0 M-IS 410 SP-33) (Bottom Portion hot dip Galvanized) with MS Plate
33 kV, V Type cross arm made of MS Channel 125X65X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV Bracket made of MS Channel (125X65X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 KV Polymer pin insulator with pin & nut
Earth-wire clamp made of MS Flat 65x6mm for STP SP-33 with Nut & Bolts Warshers all galvanised
33 kV Danger Board with Clamp with N&B
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Clamp for Anti climbing device with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
SINGLE Section POLE STRUCTURE As Per Annexure-c20 single section
Steel Tubular Poles 9.0 m long (STP 9.0 M-IS 410 SP-33) (Bottom Portion hot dip Galvanized) with MS Plate
33 kV top channel 125x65x6mm 3.2 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs
33 kV Bracket made of MS Channel (125X65X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 KV Polymer pin insulator with pin & nut
Earth-wire clamp made of MS Flat 65x6mm for STP SP-33 with Nut & Bolts Warshers all galvanised
33 kV Compsite Polymer Disc Insulator B & S type
Disc Fittings B&S type 70 KN for ACSR Dog
33 kV Danger Board with Clamp with N&B
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Clamp for Anti climbing device with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
DOUBLE POLE STRUCTURE As Per Annexure-C-21 A
Steel Tubular Poles 9.0 m long (STP 9.0 M-IS 410 SP-33) (Bottom Portion hot dip Galvanized) with MS Plate
33 kV top channel 125x65x6mm 3.2 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs for Double Pole
Cross bracing Set 65x65x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
33 KV Polymer pin insulator with pin & nut
33 KV E Clamp with Nut & bolts all Galvanised
33 KV GI fish Plate
33 kV Compsite Polymer Disc Insulator B & S type
Disc Fittings B&S type 70 KN for ACSR Dog
Earth-wire clamp made of MS Flat 65x6mm for STP SP-33 with Nut & Bolts Warshers all galvanised
33 kV Danger Board with Clamp with N&B
PG clamp/Wedge type for ACSR Dog
Aluminum Binding wire & tape
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Clamp for Anti climbing device with Nuts, Bolts & Warshers all galvanized.
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
FOUR POLE STRUCTURE As Per Annexure-C-22 A
Steel Tubular Poles 9.0 m long (STP 9.0 M-IS 410 SP-33) (Bottom Portion hot dip Galvanized) with MS Plate
33 kV top channel 125x65x6mm 3.2 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs
Cross bracing Set 65x65x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
33 KV Polymer pin insulator with pin & nut
33 KV E Clamp with Nut & bolts all Galvanised
33 kV Compsite Polymer Disc Insulator B & S type
Disc Fittings B&S type 70 KN for ACSR Dog
Earth-wire clamp made of MS Flat 65x6mm for STP SP-33 with Nut & Bolts Warshers all galvanised
33 kV Danger Board with Clamp with N&B
PG clamp/Wedge type for ACSR Dog
Aluminum Binding wire & tape
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Clamp for Anti climbing device with Nuts, Bolts & Warshers all galvanized.
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
ACSR DOG CONDUCTOR With 3% Sag As Per Annexure-C-23
ACSR Dog Conductor for Phase with 3% sag.
EARTH WIRE 7/1.6mm 16 SWG with 3% sag.
Jointing Sleeve for Dog Conductor
GUARDING OF LINE AS PER Annexure -C-17 (DP)
Guarding channel 100x50x6 mm,3750 mm long with holding clamp, nut & bolts etc. all galvanized (For Double pole)
PP of suitable size for Top portion of STP-410, SP-33 Pole
GI Eye Bolt 16mm dia, 236mm long for guarding
8 SWG GI wire
GI Wire 6 SWG
G.I. Wire No. 16 SWG for binding
GUARDING OF LINE AS PER Annexure -C-17 A (SP)
Guarding channel 100x50x6 mm,2000 mm long with holding clamp, nut & bolts etc. all galvanized (For Single pole)
PP of suitable size for Top portion of STP-410, SP-33 Pole
GI Eye Bolt 16mm dia, 236mm long for guarding
8 SWG GI wire
GI Wire 6 SWG
G.I. Wire No. 16 SWG for binding
Misc. material required for passing 11 kv/LT conductor from 33 KV line poles, connecting with old existing 33 KV line, Cost of dismentling /shifting of 11 KV /LT line pole Misc!A1
MS channel 100x50 mm galvenized
MS angle 50x50x6 mm galvenized
11 KV Polymer Disc Insulator B&S type
Disc Fittings B&S type 70 KN for ACSR Dog
11 kV Polymer Pin Insulator complete
Stay clamp with nut & bolt galvenized
33 KV Polymer pin insulator with pin & nut
ACSR Rabbit Conductor
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V-type channel X-arm galvenized
PP & galvenized clamp for SP-23
Galvenized Bracing clamp (top & bottom) for SP-23/SP-33
Earth-wire clamp made of MS Flat 50x8mm for STP SP-23 with Nut & Bolts Warshers all galvanised
LT shackle insulator
Galvenized Clamp for LT insulator mid portion SP 23 STP
Shifting realignment of 11 KV SP,DP /LT line including dismentling,re-erection,re-stringing complete work
'special type bracket'!A1 c24
MS CHANNEL 125x65x6MM all galvanized with pp clamp nut & bolt
MS CHANNEL 100x50x6MM all galvanized with pp clamp nut & bolt
MS ANGLE 75x75x6 MM all galvanized with pp clamp nut & bolt
33 KV F-BRACKET all galvanized
Stay complete (As per Annex-C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD
GI Stay Wire 7/8 SWG
33kv Stay Insulator
33 kv Stay Clamp (65x6 mm)with Nut, & Bolts all galvanized
Grouting with concreating of block size (600x600x300mm) CC ratio 1:3:6
Cost of pole plinth for protection of line
FOR single polec-38
Erection work for Single pole
Excavation of earth in mix soil, soft rock, hard rock
Cement concreting in 1:4:8 ratio
R.R. stone masonary work in 1:6 ratio cement mortar
for Double pole C-38
Erection work for Double pole
Excavation of earth in mix soil, soft rock, hard rock
Cement concreting in 1:4:8 ratio
R.R. stone masonary work in 1:6 ratio cement mortar
for Four pole c-38
Erection work for Four pole
Excavation of earth in mix soil, soft rock, hard rock
Cement concreting in 1:4:8 ratio
R.R. stone masonary work in 1:6 ratio cement mortar
New 11 KV line Underground Cable
3*120 XLPE Underground Cable (Single Circuit)
DOUBLE POLE STRUCTURE AS PER Annexure
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV top channel 100x50x6mm 2.2 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs(For double pole)
PP of suitable size for Top portion of STP-410, SP-23 Pole
Cross bracing Set 50x50x6mm with Belting angle of 50x50x6mm with clamps bolts & nuts all galvanized, as per SBD
Base Channel (100X50X6) 2.2 mtr. Long with Clamps and fittings as per SBD specs
11 kV Polymer Pin Insulator complete
11 KV Danger board with galvenized clamp
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Clamp for Anti climbing device with Nuts, Bolts & Warshers all galvanized.
Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 6 SWG with Bolts Clamp, Washers & Nuts complete all galvenized.
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Stays Complete 11 kV Stay
11 kV Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm) with Nuts, Bolts & warshers all galvanized
Grouting with concreating of block size (600x600x300mm) CC ratio 1:3:6
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
Supply and laying of B-Class Heavy duty GI pipe as IS 1239 at Underground Road crossing, Nala crossings etc complete in all respects including Bell Mouth, long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends .GI Pipe 150 mm Dia
Supply of 11kV (E) 3cx120mm2 XLPE cable (Cable outer sheet colour as per voltage level decided by UPCL)
Supply of HDPE Pipe 160 mm dia for HT cable 3x120sqmm (with colour coding of HDPE pipe as approved by UPCL in order to differentiate other voltage cables laid in other pipes) including long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends
Laying of HT cable at the depth of about 1.2 meter as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using cable trench pullers (with Line tension Indicator) using conventional excavation method in HDPE, GI pipe:including provision of cable Labels
Pulling and Laying of 11kV (E) 3cx120mm2 XLPE cable (Cable outer sheet colour as per voltage level decided by UPCL)
Laying of High -Density Polythylene(HDPE) Pipe 160 mm Dia for 11kV 3cx120 sqmm XLPE Cable (colour of HDPE Pipe as per voltage level decided by UPCL) using conventional excavation method
Making of Trench using conventional excavation method as per Approved Drawing by UPCL. as per Approved Drawing by UPCL.
Supply and laying of B-Class Heavy duty GI pipe as IS 1239 at Underground Road crossing, Nala crossings etc complete in all respects including Bell Mouth, long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends .GI Pipe 100 mm Dia
Heat Shrinkable jointing kit for 11 kV 3cx120 Sq. mm. XLPE outdoor (including Extra Long Copper braid for Cable Earthing As Per Site Requriment)
Cable jointing kit straight through for 3cx120 Sq. mm. XLPE Cable
11 KV T-Connector (As per Cable current Capacity )
Lightening Arrestors Polymer (9kV, 5kA)
Supply and installation of Chemical earthing station as per IS 3043 complete with GI earthing electrode ,Bentonite, . Conductor upto test link, test link,earthing chamber, 450x450 mm C.I. Manhole /Precast CC chamber etc.
Supply and Fixing of Cable RCC Route Marker
New 11 KV Line with ACSR Conductor
11 KV New line with Rabbit conductor SP-23
11 KV single ckt A/B type tower Annexure Tower
11 kV Disc Fittings B&S type 45 KN for ACSR Rabbit
11 KV Polymer Disc Insulator B&S type
Fabricated galvanised 11 kv A/B type tower as per approved drawing.
Excavation of earth in mixed soil
setting of stub of 33 kv tower using tan plates etc complete work.as per approved drawing.
Cement concreating in 1:3:6
Number Plate with galvenized clamp, nut & bolt
Danger Board with galvenized clamps, nut & bolt
PG clamp/Wedge type for ACSR Rabbit
RYB coloured phase indicator
cross bridge damper for rabbit conductor
Bird guard for 11 kv tower
G.I fitting for earthwire 7/16 bolted
Single Pole as per Annexure
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator complete
11 KV Danger board with galvenized clamp
Earth-wire clamp made of MS Flat 50x8mm for STP SP-23 with Nut & Bolts Warshers all galvanised
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Clamp for Anti climbing device with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 6 SWG with Bolts Clamp, Washers & Nuts complete all galvenized.
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
Single Section Pole as per Annexure
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV MS channel 100x50x6mm 1.13 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs
PP of suitable size for Top portion of STP-410, SP-23 Pole
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator complete
11 KV Polymer Disc Insulator B&S type
11 kV Disc Fittings B&S type 45 KN for ACSR Rabbit
Earth-wire clamp made of MS Flat 50x8mm for STP SP-23 with Nut & Bolts Warshers all galvanised
PG clamp/Wedge type for ACSR Rabbit
11 KV Danger board with galvenized clamp
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Clamp for Anti climbing device with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 6 SWG with Bolts Clamp, Washers & Nuts complete all galvenized
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
Double Pole structure as per Annexure
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV top channel 100x50x6mm 2.2 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs(For double pole)
PP of suitable size for Top portion of STP-410, SP-23 Pole
Cross bracing Set 50x50x6mm with Belting angle of 50x50x6mm with clamps bolts & nuts all galvanized, as per SBD
11 kV Polymer Pin Insulator complete
GI Fish Plate 50x8mm for 11 kv DP
11 KV Polymer Disc Insulator B&S type
11 kV Disc Fittings B&S type 45 KN for ACSR Rabbit
Earth-wire clamp made of MS Flat 50x8mm for STP SP-23 with Nut & Bolts Warshers all galvanised
11 KV Danger board with galvenized clamp
PG clamp/Wedge type for ACSR Rabbit
Aluminum Binding wire & tape
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Clamp for Anti climbing device with Nuts, Bolts & Warshers all galvanized.
Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 6 SWG with Bolts Clamp, Washers & Nuts complete all galvenized
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
Four Pole structure as per Annexure
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV top channel 100x50x6mm 2.2 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs for SP-23
PP of suitable size for Top portion of STP-410, SP-23 Pole
Cross bracing Set 50x50x6mm with Belting angle of 50x50x6mm with clamps bolts & nuts all galvanized, as per SBD
11 kV Polymer Pin Insulator complete
11 kV E Clamp made of MS Channel (50X8)mm with Bolts & Nuts All galvenized
11 kV Disc Fittings B&S type 45 KN for ACSR Rabbit
11 KV Polymer Disc Insulator B&S type
Earth-wire clamp made of MS Flat 50x8mm for STP SP-23 with Nut & Bolts Warshers all galvanised
11 KV Danger board with galvenized clamp
PG clamp/Wedge type for ACSR Rabbit
Aluminum Binding wire & tape
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Clamp for Anti climbing device with Nuts, Bolts & Warshers all galvanized.
Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 6 SWG with Bolts Clamp, Washers & Nuts complete all galvenized
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
ACSR Rabbit Conductor as per Annexure
ACSR Rabbit Conductor
EARTH WIRE 7/1.6mm 16 SWG with 3% sag.
Jointing Sleeve for Rabbit Conductor
Guarding of 11 KV line. for DP as per Annexure
Guarding channel 100x50x6 mm,2700 mm long with holding clamp,nut & bolts etc. all galvanized as per SBD (DP)
PP of suitable size for Top portion of STP-410, SP-23 Pole
GI Wire 6 SWG
8 SWG GI wire
GI Eye Bolt 16mm dia, 236mm long for guarding
G.I. Wire No. 16 SWG for binding
Guarding of 11 KV line. for SP as per Annexure
Guarding channel 100x50x6 mm,1600 mm long with holding clamp, nut & bolts etc. all galvanized as per SBD (SP)
PP of suitable size for Top portion of STP-410, SP-23 Pole
GI Wire 6 SWG
8 SWG GI wire
GI Eye Bolt 16mm dia, 236mm long for guarding
G.I. Wire No. 16 SWG for binding
Stay complete as per Annexure
11 kV Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm) with Nuts, Bolts & warshers all galvanized
Grouting with concreating of block size (600x600x300mm) CC ratio 1:3:6
Special type bracket for 11 KV
MS CHANNEL 100x50x6MM all galvanized
MS Angle 65x65x6MM all galvanized
MS CHANNEL 100x50x6MM all galvanized
Special Bracket PP & CLAMP with Nut & Bolt all galvanized
11 KV F-BRACKET all galvanized
Cost of pole plinth for protection of line
for Single pole
Erection work for Single pole
Excavation of earth in mix soil, soft rock, hard rock
Cement concreting in 1:4:8 ratio
R.R. stone masonary work in 1:6 ratio cement mortar
for Double pole
Erection work for Double pole
Excavation of earth in mix soil, soft rock, hard rock
Cement concreting in 1:4:8 ratio
R.R. stone masonary work in 1:6 ratio cement mortar
for Four pole
Erection work for Four pole
Excavation of earth in mix soil, soft rock, hard rock
Cement concreting in 1:4:8 ratio
R.R. stone masonary work in 1:6 ratio cement mortar
New LT Line: Proposed Cabling Works for New DTR New LT Line with AB Cable
New LT line with Insulated ABC of 3x95+1x70+1x16 Sq.mm. for Hills
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
L.T. Insulation Piercing Connectors (16 sq.mm. - 16 sq.mm.) suitable for street light connection
PG Connector/Wedge type 70 Sqmm.
Mid span jointing sleeves (95 Sq.mm.)
Mid span jointing sleeves (16 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x95+1x70+1x16 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
1x16 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
LT Stay complete Annexure
11 kV Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm) with Nuts, Bolts & warshers all galvanized
Grouting with concreating of block size (600x600x300mm) CC ratio 1:3:6
Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG with Bolts Clamp, Washers & Nuts complete all galvenized
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
New DTR
Plinth Mounted New DTR 100 KVA
11/0.433 kV 100 kVA Distribution Transformer (Level 2 New)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
MS Channel 125x65x6mm, 2.800mtr. long (Top Channel) with all fixing arrangment Clamps, Nuts & Bolts all galvanized as per SBD specs
PP of suitable size for Top portion of STP-410, SP-23 Pole
MS Channel 125x65x6mm, 1.300 mtr. long (Tee off) with clamps ,Bolt and nuts all galvanized as per SBD specs
MS Channel 125x65x6mm, 2.800 mtr. Long (for Transformer Base) with all fixing arrangment Clamps,Nuts & Bolts all galvanized as per SBD specs
PP of suitable size for Bottom portion of STP-410, SP-23 Pole
11 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type, Gang Operated, AB Switch
MS Channel 100x50x6mm 2 no. 2.8 mtr. Long, Clamp,Nuts&Bolts all galvanized as per SBD specs for AB Switch.
11 kV Drop out fuse set (25 kVA)
MS Channel 100x50x6mm 2.8 mtr. Long, Clamp,Nuts&Bolts all galvanized as per SBD specs for DO fuse set.
PP of suitable size for Middle portion of STP-410, sp-23 Pole
11 kV Polymer Pin Insulator complete
GI Fish Plate 50x8mm for 11 kv DP
11 KV Polymer Disc Insulator B&S type
11 kV Disc Fittings B&S type 45 KN for ACSR Rabbit
LT panel with protection equipment along with MCCB, Earth Fault Relay (EFR) etc. including fixing arrangement for 100kVA T/F.
DTR Metering Cubicals with Three Phase, Four Wire, 0.5 Class, Energy Meter for 3-Phase 100kVA Distribution Transformer
LTDB & DTR Mereting channel 100x50x6mm 2.8 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs
ACSR Rabbit Conductor
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole)
Clamp for Anti climbing device with Nuts, Bolts & Warshers all galvanized.
11 kV Danger Board with Clamp with N&B
Lightening Arrestors Polymer (9kV, 5kA)
Compound filled earthing/Chemical Earthing(with GI Strip 25x3mm for Neutral Earthing of Transformer Annexure C 37 A
Compound filled earthing/Chemical Earthing(with GI Strip 25x3mm for Neutral Earthing of Transformer
G.I. Strip 35x6mm
Compound filled earthing/Chemical Earthing of Transformer Body(with GI strip 25x3mm),Other structure& Equipment( with GI Wire of 8 SWG) Annexure C 37 B
Compound filled earthing/Chemical Earthing of Transformer Body(with GI strip 25x3mm),Other structure& Equipment( with GI Wire of 8 SWG)
8 SWG GI wire
G.I. Strip 35x6mm
Compound filled earthing/Chemical Earthingof Lightning Arrestor with GI Strip 25x3mm Annexure C 37 C
Compound filled earthing/Chemical Earthingof Lightning Arrestor with GI Strip 25x3mm (Double earthing).
G.I. Strip 35x6mm
Aluminum lugs HT side
Aluminum crimping lugs LT side
70 Sq.mm.,single core `XLPE insulated un-armoured aluminium conductor cable
120 Sq.mm.,single core `XLPE insulated un-armoured aluminium conductor cable
Stay complete (As per Annex-F-15)
11 kV Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm) with Nuts, Bolts & warshers all galvanized
Grouting with concreating of block size (600x600x300mm) CC ratio 1:3:6
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07 Annexure C37
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm, Bolts, Washers & Nuts complete all galvenized as per Drw. REC/RDSS/GEN/07
GI Wire 6 SWG
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) of (CC ratio 1:2:4) as per scope of work in SBD
Construction of plinth for Transformer(3x3x1 mtr mtr) above GL with shed.
Excavation of earth in mixed soil
Cement concreating in 1:3:6
RR Masonary 1:3
Sign Board
Sign Board 6x4 feet (lengh x breadth)
Sign Board 6x4 feet (lengh x breadth) made of MS sheet 14 Gauge(1.6mm thickness) with angle suport of (3"x3",6mm) and height of board 6 feet fromm ground level to bottom of board and length of angle to be buried in the ground 1.50 feet with 1 feet hole pass inside,painting on board ( enamel paint with red oxide base coat)and printing on board (colour printing by Screen printing method)
Sign Board 4x3 feet (lengh x breadth)
Sign Board 4x3 feet made of MS sheet 14 Gauge(1.6mm thickness) with angle suport of (3"x3",6mm) and height of board 6 feet fromm ground level to bottom of board and length of angle to be buried in the ground 1.50 feet with 1 feet hole pass inside,painting on board ( enamel paint with red oxide base coat) to indicate Name of scheme, name of implemention agency and capacity of S/s
Description of Work / Item(s)
Amount
Earth work in excavation by mechanical means (Hydraulic excavator ) manual means in foundation tranches (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. (All kinds of soil).
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5m
Supplying and filling in plinth with Jamuna sand under floors including. Watering, ramming consolidating and dressing complete.
Earth filling under floor and in S/S area including cost of earth. Earth to be obtained from outside the corporation area including its cartage watering, dressing, ramming in 20cms. thick layers and including all leads and lifts etc.(Rates Approved by S.E. Civil vide letter No. 410- ECC/A.O.R. dated 01-06-2012)
Clearing jungle including uprooting of rank vegetation, grass, brush wood trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Providing and Laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level:1:2 :4 (1 Cement :2 coarse sand: 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level:1:4 :8 (1 Cement :4 coarse sand: 8 graded stone aggregate 40 mm nominal size)
Providing and laying damp-proof course 40 cm thick with cement concrete 1:2:4 ( 1 cement :2 coarse sand: 4 graded stone aggregate 12.5 mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work @ 1 kg per 50 kg of cement.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level: 1:1:5:3 (1 cement : 1.5 coarse sand: 3 graded stone aggregate 20 cm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level excluding cost of centering, shuttering, finishing and reinforcement. 1:1:5:3 (1 cement : 2 coarse sand 4 graded stone aggregate 20 cm nominal size). Columns
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral/ stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5 : 3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting propping etc. and removal of form for: Foundations footings, bases of columns, etc. For mass concrete.
Centering and shuttering including strutting propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform.
Centering and shuttering including strutting propping etc. and removal of form for: Shelves (Cast in situ)
Centering and shuttering including strutting propping etc. and removal of form for: Lintels, beams, plinth beams girders, bressumers and cantilevers,
Centering and shuttering including strutting propping etc. and removal of form for:. Columns, Pillars, Piers, Abutments, Posts and Struts.
Centering and shuttering including strutting propping etc. and removal of form for:. Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like.
Centering and shuttering including strutting propping etc. and removal of form for. Weather shade, Chaffas, corbels etc. including edges.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (Cold Twisted Bars ).
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Above plinth level. (Cold Twisted Bars ).
Add or deduct for plaster drip course/groove in plastered surface or moulding to R.C.C projection
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:4( 1 cement : 4 coarse sand)
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:6 ( 1 cement : 6 coarse sand)
Brick work with F.P.S. Bricks of class designation 75 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 ( 1 cement : 6 coarse sand)
Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above planth level up to floor V level. Cement morat 1:4 ( 1 cement : 4 coarse sand)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
Coursed rubble masonry (first sort) with hard stone in foundation and plinth with: Cement mortar 1:6( 1cement:6 coarse sand)
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4mm in both directions with wire of dia 0.63 mm all complete With 12 mm mild steel U beading
Providing and fixing ISI marked oxidised M.S. pressed butt hinges with necessary screws etc. complete. 125x65x2.12 mm
Providing and fixing ISI marked oxidised M.S. pressed butt hinges withnecessary screws etc. complete 100x58x1.90 mm
Providing and fixing ISI marked oxidised M.S. pressed butt hinges withnecessary screws etc. complete 75x47x1.70 mm
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete 100x10 mm
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete 100 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete200x10 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium sliding door bolts ISI marked anodised (Anodic coating not less than grade AC 10 as per IS:1868)transparent or dyed to required colour or shade with nuts and screws etc. complete: (100x10mm)
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary scerews etc. complet: 125mm
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary scerews etc. complet: 100mm
Providing and fixing aluminium handles floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary scerews etc. complet: Single rubber stopper
Providing and fixing aluminium handles floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary scerews etc. complet: Twin rubber stopper
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer
Providing and fixing pressed steel door frames conforming to IS: 4351 manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and ifrequired angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineerin-charge Fixing with adjustable lugs with split end tail to each jamb(profile-c)
Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Steel work welded in built up sections/ framed work including cutting, hoisting fixing in position and applying a priming coat of approved steel primer susing structural steel etc. as required.
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 5.5 mm thick glass panes
Cement concrete flooring 1:2:4 (1 cement : 2coarse sand : 4 gradd stone aggregate) finished with a floating coat of neat cement including cement slurry, (40 mm thick with 20mm nomnal size stone aggregate).
Providing and fixing glass strips in goints of terrazo/cement concrete floors. (40mm wide and 4mm thick)
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacture) of approved make in all colours, s@ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS; n 20 mm thick Cement Mortar 1:4 ( 1 cement :4 Coarse sand )
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 (i) Single socketed pipes (75mm diameter)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointin with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. (i) Single socketed pipes (110mm diameter)
12mm cement plaster of mix: 1:4 (1cement : 4coarse sand)
12mm cement plaster of mix: 1:6 (1cement :6coarse sand)
15mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1cement :6coarse sand)
6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand)
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepate the surface even and smooth complete
Distempering with oil bound washable distemper or approved brand and manufacture to give an enen shade . New work (two or more coats ) over and including priming coat with cement primer.
Finishing wall with textured exterior paint of required shade: New work (two or moar coats applied @ 3.28 ltr/10sqm over and including base coat of water proofing cement paint applied @2.20kg/10sqm.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved prand and manufacture.
Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to repare the surface even and smooth complete.
Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I.staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to bemade per metre cost of total length of barbed wire used. With G.I. barbed wire metre
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets 15mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
Providing and fixing 600x450mm beveled edge mirror of superior glass (of approved quality ) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing anf fixing soil, waste and vent pipes: 100mm dia( Sand cast iron S&S pipe as per IS:1729)
Providing anf fixing soil, waste and vent pipes: 75mm diameter: ( Sand cast iron S&S pipe as per IS:1729)
Providing and fixing M.S. holder-bat clamps of approved design to Sand cast iron/cast iron(spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4mix( 1cement :2 coarse sand :4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. For 75mm dia. pipe
Providing and fixing plain bend of required degree. 100mm ( Sand cast iron S&S as per IS-1729)
Providing and fixing single unequal plain invert branch of require degree: 100x100x75mm (sand coast iron S&S as per IS-1729)
Providing and fixing terminal guard: :75mm (Sand cast iron S&S as per IS- 1729)
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floorsSand cast iron S&S as per IS: 3989
P/F PTMT Tower rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm,weighing not less than 190 gms.
Concealed pipe including painting with anti corrosive bitumasiic paint cutting chases and making good the wall . 15mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 15mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 20mm dia nominal bore
Constructing masonry Chamber 30x30x50 cm inside with 75 class designation brick work in cement mortar 1:4 (1cement : 4coarse sand) for stop cock with C.I. surface bozx 100x100x75mm (insside) with hinged cover fixed in cement concrete slab 1:2:4 mix ( 1cement : 2coarse sand: 4 graded stone aggregate 20mm nomnal size) necessary excavation foundation concrete 1:5:10( 1cement:5fine sand :10 graded stone aggregate 40mm nominal size) and inside plastering with cemnt mortar 1:3 (1cement:3coarse sand ) 12mm thick finsished with a floating coat of neat cement complete as per standard design . With F.P.S. bricks
Providing and placing on terrace (at all floor levels) polyethylene water stonrage tank ISI: 12701 marked with cover and suitable locking arrangement and making necessary holes for nilet, outlet and overflow pipes but without fittings and the base support for tank.
Providing anf fixing C.P. brass bib cock of approved quality conforming to IS: 8931 (15mm nominal bore).
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS Standards and weighing not leass than 690 gms. (15mm nominal bore)
Providing and fixing C.P. brass stop cock (concealed ) of standard design and of approved make conforming to IS:8931. (15mm nominal bore)
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931 a(15mm nominal bore)
P/F PTMT soap dish holder having lengthof 138 mm breadth of 102mm height of 75 mm with concealed fitting arrangements weighing not less than 106 gms
Providing and fixing aluminium work for doors, windows ventilators and partitions with extruded built up standard tubular sections/ approprate Z ections and other sections of approprate make conforming to IS: 733 and IS: 1285 fixed with rawl plugs and screws of with fixing clips or with expanision hold fasteners including necessary filling up of gapu at junctions at top bottom and sides with required PVC/ neoperene felt etc. For fixed portion. Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing aluminium work for doors, windows ventilators and partitions with extruded built up standard tubular sections/ approprate Z ections and other sections of approprate make conforming to IS: 733 and IS: 1285 fixed with rawl plugs and screws of with fixing clips or with expanision hold fasteners including necessary filling up of gapu at junctions at top bottom and sides with required PVC/ neoperene felt etc. : For shutters of doors windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle borad conforming to IS: 12823 Grade I Type II in panelling fixied in aluminum doors windows sutters and partition frames with C.P. brass/ stainless stell screws etc.
Providing and fixing glazing in aluminium door, window ventilator shutters and partitons etc. with PVC/ neoprene gasket etccomplete as per the architectural) With flot glass panes of 5.50mm thickness
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS: 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sqmm FR PVC insulated copper conductor single core cable 1.5 sqmm FR PVC insulated copper conductor single core cable etc as requited. GROUP B
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required Circuit / sub main wiring in PVC conduit 2*1.5 Sq.M * 1*1.5 Sq.M
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ sub main wiring in PVC conduit 2*2.5 Sq.M*1*2.5Sq.M
S/F stepped type electronic fan regulator on the existing moduler plate switch box including connection but excluding modular plate etc.as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
S/F 8ways double door single pole and netural,sheet steel,MCB D.B 240 volts on surface/recess complete with tinned copper bus bar netural bus bar, earth bar,din bar detachable gland plate,interconnections, phosphatized and power painted including earthing etc. as required.
S/F 5amp to 32amp rating 240 volts,B series,MCB suitable for lighting and other loads of single pole in the existing MCB D.B complete with connection,testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40AMP rating double pole 240 V isolater in existing MCB DB complete
Earthing with GI earth plate600x600x6mm thick including accessories and providing masonary enclosure with cover plate having locking arrengment and watering pipe etc.as required (but without charcoal or coke and salt)
Wiring for circuit/submain wiring alongwith earthwire with the following sizes of FRLS PVC insulated copper conductor , single core cable in surface/recessed PVC conduit as required. 2X4 sqmm + 1X4 sqmm earthwire
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineerin-Charge :a. Flamed finish granite stone slab Jet Black, Cherry Red, EliteBrown, Cat Eye or equivalent.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Earthing with Copper earth plate600x600x3mm thick including accessories and providing masonary enclosure with cover plate having locking arrengment and watering pipe of 2.7 metre long etc.as required (but with charcoal or coke and salt)
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Vide CPWD Letter No. E-9059857/9 (New Technology) /C.E.(Ren.)CSQ/2019 dated 18/11/2019
Supplying of 20Watt LED Tubelight Philips or equivalent make as approved by E.I. S.E. letter no-832 /ECC/D.Dun/Extra Item Dated-29-08-2022
Supplying of Exhaust Fan 250mm sweep of Orient or equivalent make as approved by E.I. S.E. letter no-832 /ECC/D.Dun/Extra Item Dated-29-08-2022
Supplying and Installation of 1.0 H.P. Water pump Havells or equivalent make all complete as per direction of E.I. S.E. letter no-832 /ECC/D.Dun/Extra Item Dated-29-08-2022
Supplying and stacking at site Good Earth
Engaging Suitable Beldar for Miscellaneous Civil Works .(Based on DSR Code 0114) S.E. letter no-892 /ECC/D.Dun/Extra Item Dated- 12-09-2022
Supply of Stone for Masonary Work.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer onboth side of the sheet and polyester top coat 15-18 microns using selfdrilling/ self tapping screws complete : Ridges plain (500 - 600mm)
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Gutter .(600 mm over all girth)
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 75 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 75 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain)75 mm Shoe
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain)110 mm Shoe
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 75 mm
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete.
R&C INFRAENGINEERS PRIVATE LIMITED
R&C INFRAENGINEERS PRIVATE LIMITED
RC POWER PROJECT LIMITED
R&C INFRAENGINEERS PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_86034.xls
BOQ • 1.04 MB
MANA_PQR.xls
Other Document • 0.06 MB
Guildlines_Amendements_issued_By_PFC.rar
Tender Documents • 12.13 MB
Mana_Tender_Specs-SBD.rar
Additional Documents • 18.78 MB
Technical_UPCL_RDSS.rar
Additional Documents • 14.16 MB
VendorlistBorderpost.pdf
Additional Documents • 0.03 MB
Download all tender documents and submit your bid